You are on page 1of 2

RECTANGULAR BEAM

REFERENCE CALCULATION OUTPUT REMARKS


DATA:
a. Length, L = 9.00 m 9000.000 mm
b. width, b = 0.30 m 300.000 mm
c. Height, h = 0.50 m 500.000 mm
d. Concrete Grade =
e. Concrete Cover (Cc) = 25.00 mm

Refer Table 1.2 RC


textbook: Page 17 f. fck = 25.00 N/mm2

g. fyk = 500.00 N/mm2


h. Unit weight of concrete
and finishes = 25.00 kN/m3
i. SW slab + finishes = 11.875 kN/m2

j. Distributed Load from slab = 9.375 kN/m

Table 1.4 Structural


Analysis textbook j. Qk (apartment) = 1.92 kN/m2 = 7.296 kN/m
k. effective depth,d = 470.000 mm

1. Area = 0.150 m2
i. SW beam = 3.750 kN/m

Ultimate Load, wu = 1.35Gk +


1.5Qk
Gk: SW beam + SW slab = 13.125 kN/m
Qk = 7.296 kN/m

ultimate load, wu = 28.663 kN/m

Maximum Design Moment,


M = 290.210 kN.m

BENDING REINFORCEMENT

doubly
K = M/(bd˄2fck) = 0.175 reinforcement
compression
reinforcement required
k bal = 0.167

Assume d' = 50 mm
d'/d = 0.11

COMPRESSION STEEL
As' = 74.073 mm2

Prepare 3 H10 bars for


compression
reinforcement
TENSION STEEL
As 1724.409 mm2
prepare 2 double layer
H25
for tension
reinforcement
RECTANGULAR BEAM

PRICING
CALCULATION OUTPUT REMARKS

1. Volume of concrete = 1.350 m3


1 m3 Grade 30 concrete = 300.000 RM
price = 405.000 RM

2. Area of formwork = 1.350 m3


1 m3 of formwork = 50.000 RM
Price = 67.500 RM

3. Amount of steel
1 kg of steel = 4.000 RM
3H10 = 53.021 kg
4H25 = 441.844 kg
price for 3H10 = 212.085 RM
price for 4H25 = 1767.375 RM

Total for beam = 2451.960 RM

Flat slab is more economic, but the flat slab is too thick and this will cause in decreasing in space for
appliances such as fan.
Use 2-way slab and Rectangular I-beam