You are on page 1of 8

INFORMATION

Vacuum Pad with Ejector


Pad Diameter: Ø 63, Ø 80 RoHS

Ejector and pad are integrated.


Space saving and reduced piping labour! Bellows type
with groove

Two-stage ejector
More efficient ejector
Suction
flow rate 50 % increased
∗ 1) Compared with SMC single stage ejector
∗1
Air
consumption 30 % reduced ∗1

Two-stage ejector
First ejector Second ejector Flat type
with groove

Q1 + Q2 = Suction flow rate

With One-touch fitting


Metric: Ø 4, Ø 6 EXH
Inch: Ø 5/32", Ø 1/4"

Strainer SUP
Prevents access of contamination
through the pad suction port.
Silencer

Improved ease
∗2
of removal
With groove
Dents and bumps on the adsorption surface
prevent the workpiece from sticking to it.
This facilitates easy removal.
Ejector silencer
By dispersing the exhaust in all directions,
undesired exhaust noise can be silenced while still
exhibiting maximum vacuum performance.

¡Structure designed to minimise clogging

Ports for Vacuum release, Pressure sensor, Daisy-chain piping Daisy-chain vacuum piping is possible.
<Daisy-chain
Daisy-chain
y-chain piping exampl
example>
ex

Shot-blasted
Micro-dents and bumps are formed on the adsorption surface.
Workpieces can be removed easily.

∗2 Compared with current ZP series

With ejector Without ejector Daisy-chain


D aisy-chain
ais
pip
piping

ZHP Series
14-EU632-B-UK
ZHP Series

Easier maintenance
Mounting with the lock plate reduces
the pad replacement work steps!

Lock plate

q
Remove the lock screw
and slide the lock plate.
Lock screw
Uses an isolated structure.
¡The lock plate is used to facilitate separation.
¡Rubber and metal parts can be disposed of separately. Holder

Holder
Pad
Plate

Stud w Remove the stud from


the bottom of the pad.

Nozzle nominal
Pad diameter Pad form Pad material Mounting
size ∗2 [mm]
Metric size (Male thread/Female thread)
Ø 63 Bellows type NBR (Black) ∗1 M8 Ø 0.7
with groove Silicone rubber (White) M10 Ø 1.0
Flat type Urethane rubber (Brown) Inch size (Male thread/Female thread) Ø 1.2 ∗1 Refer to the back cover for
Ø 80 with groove FKM (Black) ∗1 5/16-18UNC Ø 1.5 identification method.
3/8-16UNC ∗2 With ejector

Application Examples
Robot handling Automobile Case packer
Palletizing

1
Vacuum Pad with Ejector

ZHP
Ø 63, Ø 80
Series RoHS

How to Order

Without ejector ZHP 80 BM N B 00


With ejector ZHP 80 BM N B 10 C6 S
Pad diameter Exhaust release
elease
63 Ø 63 S Silencer exhaust
80 Ø 80
Supply (P) port
Pad form Symbol Type Port size
BM Bellows type with groove C4 Ø 4 One-touch fitting
UM Flat type with groove Metric
C6 Ø 6 One-touch fitting
N3 Ø 5/32" One-touch fitting
Pad material Inch
N7 Ø 1/4" One-touch fitting
N NBR (Black)∗
S Silicone rubber (White) Mounting
U Urethane rubber (Brown) Symbol Type Thread Size Ejector/
F FKM (Black)∗ A Male M8 Nozzle nominal size [mm]
B Metric thread M10 07 Nozzle: Ø 0.7
∗ Refer to the back cover for
C size Female M8 10 Nozzle: Ø 1.0
identification method.
D thread M10 12 Nozzle: Ø 1.2
E Male 5/16-18UNC 15 Nozzle: Ø 1.5
F Inch thread 3/8-16UNC
G size Female 5/16-18UNC
H thread 3/8-16UNC

Ejector Specifications Recommended Work Load


[N]
ZHP첸첸첸-07쏔 ZHP첸첸첸-10첸 ZHP첸첸첸-12첸 ZHP첸첸첸-15첸 ZHP63첸 ZHP80첸
Nozzle nominal size [mm] 0.7 1.0 1.2 1.5 Horizontal lifting 66 106
Max. suction flow rate [l/min (ANR)]∗ 30 52 63 78 Vertical lifting 33 53
Air consumption [l/min (ANR)]∗ 24 40 58 87 Use this product with the recommended work
Vacuum pressure reached [kPa] −91 load or less. The transfer wor k over the
Standard supply pressure [MPa] 0.35 recommended wor k load may cause the
∗ Standard supply pressure vacuum pressure to decrease by the air leak.
The work load shown above is the value when
the vacuum pressure reaches –85 kPa, and that
is calculated by multiplying the theoretical value
Response Time by a safety factor of “1/4” for the horizontal lifting
[ms] or “1/8” for the vertical lifting. The vacuum
Nozzle size ZHP첸BM첸-07첸 ZHP첸BM첸-10첸 ZHP첸BM첸-12첸 ZHP첸BM첸-15첸 pressure reached may vary depending on the
Pad dia.
workpiece (permeability, etc.) Calculate the
Ø 63 295 143 120 86
actual work load in accordance with the vacuum
Ø 80 455 221 190 140
pressure reached.
Response time means a period of time that the vacuum pressure reaches –57 kPa after the externally
installed valve has been turned ON when the bellows type pad is used and the supply pressure is 0.35 MPa.

Weight
Material: NBR, Mounting: A [g] q Weight Difference by Mounting Style [g]
ZHP63BMNA-첸C6S 184 B C D E F G H
ZHP80BMNA-첸C6S 224 20 −5 14 7 25 1 11
ZHP63UMNA-첸C6S 167
ZHP80UMNA-첸C6S 175 w Weight Difference by Material [g]
앫 For the ZHP첸첸첸A-00 (without ejector), weight shown above –12 g. Pad diameter/form Silicone rubber Urethane rubber FKM
앫 When the mounting symbol is other than “A”, add the weight q shown in the table on ZHP63BM −2.9 0 20.3
the right to the weight described in the table above. ZHP80BM −5.0 0 35.1
앫 When the material is other than NBR, add the weight w shown in the table on the ZHP63UM −1.5 0 10.6
right to the weight described in the table above.
ZHP80UM −2.1 0 15.5
앫 This weight includes the accessory weight.
2
ZHP Series

Exhaust Characteristics/Flow-rate Characteristics (Representative Value)

Exhaust Characteristics Flow Rate Characteristics

ZHP쏔-07쏔 ZHP쏔-07쏔 (Supply pressure: 0.35 MPa)


−100 50 −100

Air consumption [l/min(ANR)]


−90 45

Suction flow [l/min(ANR)]


Vacuum pressure [kPa]

Vacuum pressure [kPa]


−80 Vacuum pressure 40 −80
−70 35
−60 30 −60
−50 Suction flow 25
−40 20 −40
−30 15
−20 10 −20
−10 Air consumption 5
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 10 20 30 40
Supply pressure [MPa] Suction flow [l/min(ANR)]

ZHP쏔-10쏔 ZHP쏔-10쏔 (Supply pressure: 0.35 MPa)


−100 100 −100
Air consumption [l/min(ANR)]

−90 90
Suction flow [l/min(ANR)]
Vacuum pressure [kPa]

Vacuum pressure [kPa]

−80 Vacuum pressure 80 −80


−70 Suction flow 70
−60 60 −60
−50 50
−40 40 −40
−30 30
−20 20 −20
−10 Air consumption 10
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 10 20 30 40 50 60
Supply pressure [MPa] Suction flow [l/min(ANR)]

ZHP쏔-12쏔 ZHP쏔-12쏔 (Supply pressure: 0.35 MPa)


−100 100 −100
Air consumption [l/min(ANR)]

−90 90
Suction flow [l/min(ANR)]
Vacuum pressure [kPa]

Vacuum pressure [kPa]

−80 Vacuum pressure 80 −80


−70 70
−60 60 −60
−50 Suction flow 50
−40 40 −40
−30 Air consumption 30
−20 20 −20
−10 10
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 20 40 60 80
Supply pressure [MPa] Suction flow [l/min(ANR)]

ZHP쏔-15쏔 ZHP쏔-15쏔 (Supply pressure: 0.35 MPa)


−100 150 −100
Air consumption [l/min(ANR)]

−90 135
Suction flow [l/min(ANR)]
Vacuum pressure [kPa]

Vacuum pressure [kPa]

−80 Vacuum pressure 120 −80


−70 Air consumption 105
−60 90 −60
−50 75
−40 Suction flow 60 −40
−30 45
−20 30 −20
−10 15
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 20 40 60 80 100
Supply pressure [MPa] Suction flow [l/min(ANR)]

3
Vacuum Pad with Ejector ZHP Series

Construction

r Component Parts
No. Description Note
e u 1 Stud
2 Strainer
w q 3 Mounting bracket
2 pcs. included for male thread mounting
A A 4 Lock nut
(Not included for female thread mounting)
5 Lock pin
6 Check valve
7 Lock plate
!0
o Replacement Parts
i No. Description Part no. Note
8 Pad ZP3E-첸첸첸 Flat/Bellows type with groove
9 Plate
!2 t !3 A-A !4 ZHP1-PL첸-A
10 Holder
TB00148 Included for metric size
11 Plug∗
TB00055 Included for inch size
12 One-touch fitting KJH첸-C2
13 Ejector assembly ZK2-EJ첸W-A
!1 14 Silencer assembly ZHP1-SA1-A
y 15 Lock screw CA00284 Included
∗ 3 pieces are included in one product. (The part numbers are for 1 piece.)

!5

Replacement Parts/How to Order


i Pad o!0 Plate assembly∗
ZP3E 80 BM N ZHP1 PL 1 A
Pad material Holder
Size (Applicable pad dia./form)
N NBR 1 Ø 63/Ø 80: Flat type, Ø 63: Bellows type
S Silicone rubber 2 Ø 80: Bellows type
U Urethane rubber Plate
∗ Part number for a set of plate and holder
F FKM

Pad form
BM Bellows type with groove !2 One-touch fitting (The order lot is 10 pieces.)
UM Flat type with groove
KJH 06 C2
Pad diameter
Applicable tubing O.D.
63 Ø 63
80 Ø 80
04 Ø4
06 Ø6
∗ When changing the
03 Ø 5/32"
pad diameter, replace
also the plate.
07 Ø 1/4"

!3 Ejector assembly
ZK2 EJ 10 W A
Nozzle nominal size
07 Ø0.7
10 Ø 1.0
12 Ø 1.2
Bellows type with groove Flat type with groove 15 Ø 1.5
4
ZHP Series

Dimensions

M Female thread M Male thread


Unlocked: 32.2
mounting mounting
PD port 2 Locked
J Unlocked
H

PD port 1

P port
L

6.2
G
10

6.2
7.8

F
Lock screw

E
7.3 1.4
Ø 14.4
A
B
C
D

N 30 69.7
Silencer
EXH.

P
In the case of Flat type
Ø15
24.7

F
E
A
PD port 3 6.2 C
K D

PD port size
Metric size: Rc 1/8
Inch size: NPT 1/8

Supply Port
Dimensions [mm] Dimensions [mm]
A B C D E F N
ZHP63BM Ø 26 Ø 45.8 Ø 63 Ø 68 12.5 33.8 C4 4.7
ZHP80BM Ø 28 Ø 57 Ø 80 Ø 85 18 41.8 C6 4.7
ZHP63UM Ø 26 — Ø 63 Ø 66 5 20.3 N3 4.7
ZHP80UM Ø 26 — Ø 80 Ø 83 5 20.3 N7 7.3

Adapter Dimensions (by Mounting Style) [mm] Circuit


G H J K L M
ZHP첸첸첸A-첸첸S 25.7 22.6 5 13 — M8 P
EXH.
ZHP첸첸첸B-첸첸S 27.1 21.2 6 17 — M10
ZHP첸첸첸C-첸첸S — — — 13 36.7 M8 depth 10
PD1
ZHP첸첸첸D-첸첸S — — — 17 39.1 M10 depth 10
ZHP첸첸첸E-첸첸S 27.45 21.8 6.75 12.7 — 5/16-18UNC PD3
ZHP첸첸첸F-첸첸S 29.43 26.82 8.33 14.28 — 3/8-16UNC PD2
ZHP첸첸첸G-첸첸S — — — 12.7 41.7 5/16-18UNC depth 11
ZHP첸첸첸H-첸첸S — — — 14.28 44.1 3/8-16UNC depth 11 V
For symbols G and H (inch-type female thread), the dimension K becomes the width across flats.
5
ZHP Series
Specific Product Precautions 1
Be sure to read this before handling. For Safety Instructions and Vacuum Equipment Precautions,
refer to “Handling Precautions for SMC Products” on SMC website, http://www.smc.eu

1 . Use the product while strictly observing the 6. Replace the pad while referring to the figure below.
precautions on vacuum equipment and taking the Lock plate
safety into consideration. Additionally, select a pad Lever on ejector side
size and material suitable for the workpiece to be
adsorbed and the operating environment. Take w
Lock plate
safety measures so that any accident, such as
Lock screw
workpiece drop does not occur during adsorption
transfer. For details, refer to the Best Pneumatics Adapter plate
No. 4 catalogue. t
q
2 . After the pad has been replaced, lock the lock plate
completely before use. (Refer to q shown in the Holder
figure below.) If the lock plate is not locked y
Non-rotating hole
completely, the pad may drop due to the vibration or
Plate
load during operation.
3 . To ensure the safety, be sure to mount the lock Pad assembly
screw on the lock plate before use. (Refer to w
shown in the figure below.) If the lock plate comes
off during operation, this may cause a serious
accident, such as pad drop or workpiece drop.
Pad
Locking status: e
Acceptable
- Lock plate 2 Lock screw r
Stud assembly
Unlocked

Adhesion q Remove the lock screw.


w Push the lever (on the ejector side) of the lock plate to slide
Stud it to a position where it stops completely.
e Pull out the pad assembly.
Locking status: r Pull out the stud assembly from the pad assembly.
Not acceptable
t Remove the holder.
y Remove the plate from the pad.
u Mount the pad in the reverse order of steps above.
Gap
Cautions on pad mounting
앫 When mounting the pad assembly on the adapter plate,
4 . If the adsorption time delay or incorrect adsorption adjust the position so that the non-rotating convex part on the
occurs, the vacuum leak due to worn out pad or bottom of the adapter plate enters the non-rotating hole in
strainer clogging may be the cause. Perform the the holder.
periodic maintenance so that any trouble such as Non-rotating convex part
workpiece drop does not occur.
5 . When connecting multiple pads to one ejector
Adapter plate
through the vacuum communication, other pads
also cannot adsorb if incorrect adsorption occurs in
o n e p a d . Ta k e s a fe t y m e a s u r e s s o t h a t t h e
workpiece does not drop during transfer.
앫 When locking the lock plate, push in
the stud assembly through the pad. If
the stud assembly is not pushed into
the adapter plate completely, the lock Stud
plate does not lock, causing pad
drop or vacuum leak.
7 . Recommended One-touch fitting to be mounted at
the PD port is the KQ2S06-01쏔S or KQ2S07-34쏔S.
One-touch fitting may interfere with the top surface of
the pad depending on the fitting dimensions. This may
cause the One-touch fitting not to be mounted.
6
ZHP Series
Specific Product Precautions 2
Be sure to read this before handling. For Safety Instructions and Vacuum Equipment Precautions,
refer to “Handling Precautions for SMC Products” on SMC website, http://www.smc.eu

8 . When supplying the vacuum release air to the PD 11. Circuit examples
port, select an appropriate product suitable for the ZHP ZHP
(With ejector) (Without ejector)
specifications so that the R port of the 2 port or 3 EXH.
P
port valve is blocked and does not leak.
9. When using the male thread mounting type product, PD3 PD1 PD1
Air filter Regulator Supply valve
do not loosen the bottom nut shown in the figure PD3

below. (The bottom nut is intended to secure the Circuit without release valve
(Usage example of vacuum connection) V PD2 V PD2
connection between the bracket for the adapter
connection and the male thread.)
Supply valve
EXH.
P
Pressure sensor
Do not loosen this nut. Male thread
Adapter connection bracket PD3 PD1
P

Adapter plate Circuit with release valve V PD2


(Usage example of pressure sensor) Release valve Restrictor

12. Pad material and appearance colour


The appearance colour of the pad may vary depending
on the material.
Material Appearance colour
NBR Black
Silicone rubber White
Urethane rubber Brown
10. Ejector exhaust may be directly released from the FKM Black∗
ejector silencer in the direction of workpieces. ∗ FKM and NBR have the same colour.
Please contact SMC if this affects adsorption. But, “F” mark is indicated on the inside
of the pad when the plate is removed.

SMC Corporation (Europe)


Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smcpneumatics.be info@smcpneumatics.be Netherlands +31 (0)205318888 www.smcpneumatics.nl info@smcpneumatics.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 (0)222119616 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 226166570 www.smc.eu postpt@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 6510370 www.smcpneumatics.ee smc@smcpneumatics.ee Russia +7 8127185445 www.smc-pneumatik.ru info@smc-pneumatik.ru
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr promotion@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 902184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031200 www.smc.nu post@smc.nu
Hungary +36 23511390 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcpneumatics.ie sales@smcpneumatics.ie Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr
Italy +39 0292711 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smcpneumatics.co.uk sales@smcpneumatics.co.uk
Latvia +371 67817700 www.smclv.lv info@smclv.lv
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing WT printing WT 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

You might also like