You are on page 1of 10

Slab Conditions

Slab
LL Ls Condition
S1 3 2 Two Way
S2 4 4 Two Way
S3 1 1 Two Way
S4 4 1 One Way
S5 4 1 One Way
S6 4 3 Two Way
S7 4 1 One Way
S8 4 3 Two Way
S9 4 1 One Way
S10 4 2 One Way
S11 4 1 One Way
S12 4 1 One Way
S13 4 1 One Way
S14 4 1 One Way
S15 4 1 One Way
S16 4 1 One Way
S17 4 5 Two Way

Thickness
Slab Condition Slab Thickness
S1 One Way Two End Continouse 0.1
S2 Two Way Simple 0.4
S3 Two Way Two End Continouse 0.066666666666667
S4 Two Way Two End Continouse 0.066666666666667
S5 Two Way Two End Continouse 0.066666666666667
S6 Two Way Two End Continouse 0.2
S7 Two Way Two End Continouse 0.066666666666667
S8 Two Way Two End Continouse 0.2
S9 Two Way Two End Continouse 0.066666666666667
S10 Two Way Two End Continouse 0.133333333333333
S11 Two Way Two End Continouse 0.066666666666667
S12 Two Way Two End Continouse 0.066666666666667
S13 Two Way Two End Continouse 0.066666666666667
S14 Two Way Two End Continouse 0.066666666666667
S15 Two Way Two End Continouse 0.066666666666667
S16 Two Way Two End Continouse 0.066666666666667
S17 Two Way Two End Continouse 0.333333333333333
Loads
Gamma Concrete 150 lb/cft
Floor Cover 50 Psf
Live Loads 80 Psf

One Way
Slab Thickness 6 Inches
Strip Width 12 Inches
Wult 303 Psf

Two Way
Slab LL LS LCondition
S1 3 2 One End Continouse
S2 4 4 One End Continouse
S3 1 1 Simple
S4 4 1 One End Continouse
S5 4 1 Two End Continouse
S6 4 3 One End Continouse
S7 4 1 One End Continouse
S8 4 3 One End Continouse
S9 4 1 One End Continouse
S10 4 2 One End Continouse
S11 4 1 One End Continouse
S12 4 1 One End Continouse
S13 4 1 One End Continouse
S14 4 1 One End Continouse
S15 4 1 One End Continouse
S16 4 1 One End Continouse
S17 4 5 One End Continouse
Max 0.4
avg 0.123529
Min 0.066667
Scondition r α β Wα Wβ
Two End Continouse
Simple
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Two End Continouse
Simple
One End Continouse
Two End Continouse

One Way
Two Way
Cantilever
Simple
One End Continouse
Two End Continouse
Seismic Analysis Based on UBC 1997

INPUT DATA
Seismic zone (1, 2A, 2B, 3, or 4) = 1
Coefficient, R = 8.5
Occupancy Category(1, 2, 3, or 4) = 3
Soil type (SA, SB, SC, SD, or SE ) = SA
No. of Stories = 25
Typical story height = 12 ft
Typical story weight = 936 kips
Coefficient, Ct = 0.03
Seismic source type ( A, B, or C ) = A
Closest distance to seismic source = 30 km

VERTICAL DISTRIBUTION ANALYSIS


Story H (ft) W (k) Fi (k) V (k) Fpx (k) Coefficient, Ca = 0.060
Roof 30 3700 160 206 Coefficient, Cv = 0.060
25th 30 0 46 160 206 Period (method A) = 2.16
24th 30 0 44 207 206 Period (method B) =
23rd 30 0 43 251 206 Zone factor, Z = 0.400
22nd 30 0 41 294 206 Importance factor, I = 1.00
21st 30 0 39 334 206 V = ( Cv I / R T ) W = 684
20th 30 0 37 373 206 V = ( 2.5 Ca I / R ) W = 2,544
19th 30 0 35 410 206 V = 0.11 Ca I W = 951
18th 30 0 33 444 206 V = ( 0.8 Z Nv I / R ) W = 740
17th 30 0 31 477 206 Whip effect force, Ft = 112
16th 30 0 29 508 206 Base shear, V = 740
15th 30 0 27 537 206 Whip force, Ft = 112
14th 30 0 25 564 206
13th 30 0 23 589 206 V= 0.038 w, (SD)
12th 30 0 21 612 206 = 0.027 w, (ASD)
11th 30 0 19 634 206
10th 30 0 17 653 206
9th 30 0 15 670 206
8th 30 0 14 686 206
7th 30 0 12 699 206
6th 30 0 10 711 206
5th 30 0 8 721 206
4th 30 0 6 728 206
3rd 30 0 4 734 206
2nd 30 0 2 738 206
Grnd 740
1 0.075 SOIL PROFILE TYPE
2A 0.15 SA
2B 0.2 SB
3 0.3 SC
4 0.4 SD
SE

k
k (max) 169.4406
k (min)
k(minZ=4)
k
k
k
Ca

Z= 0.075 Z = 0.15 Z = 0.2 Z = 0.3


0.06 0.12 0.16 0.24
0.08 0.15 0.2 0.3
0.09 0.18 0.24 0.33
0.12 0.22 0.28 0.36
0.19 0.3 0.34 0.36

Cv
Z = 0.4
0.32
0.4
0.4
0.44
0.36

You might also like