0M)
Pc
f e
Pt σc
Y
Column orientation for Plaform 1
D
b B X
Z
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio E s / Ec m = 10.25
Load data corresponding to critical load combination no 212 1.35DL+1.0 203 1.35DL+1.5WL(+Z)
Axial load Pc = 33.953 kN Max Tension = 16.679 kN
Moment about Z - Z Mzz = -0.043 kN-m
Moment about X - X Mxx = -0.754 kN-m
Resultant moment MR = 0.755 kN-m
Shear force along - Z direction Fz = -7.323 kN
Shear force along - X direction Fx = 0.032 kN
Resultant shear force FR = 7.323 kN
Geometrical data
Size of the column UC 152X152X30
Length of base plate D = 300 mm
Breadth of base plate B = 300 mm
Distance between bolts along - X direction d = 200 mm
Distance between bolts along - Z direction b = 200 mm
Distance between C.L of column and bolt in tension f = 100 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0.76 / 33.95
= 0.02 m
= 22.24 mm
D/6 = 300 / 6
= 50.00 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (22.24 - 300 / 2)
= -383.27
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (100 + 22.24)
300
= 7865.65
K3 = - K2 (D / 2 + f)
= - 7865.65 x (300 / 2 + 100)
= -1966412.97
Y3 + -383.27 Y2 + 7865.65 Y + -1966412.97 = -8141878
Solving this equation,
Y = 220.23 mm
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
= Not Required kN
Tensile force on one bolt = 16.679 / 2
= 8.34 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 30.14 kN > 8.34 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 33.953 x 10^3 + 0 x 10^3 )
=
300 x 300
= 0.38 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.38 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 154.4 mm
Depth of the column along - Z direction = 157.6 mm
Projected length of base plate from the face of the column
along - X direction a = (300 - 154.4) / 2
= 72.80 mm
Projected length of base plate from the face of the column
along - Z direction b = (300 - 157.6) / 2
= 71.20 mm
Maximum projected length c = 72.80 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 72.80 x 3 x 0.38
165
= 6.03 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 4.17 kN
Moment arm = (154.4 - 200) / 2
= 22.80 mm
= 0.023 m
Moment at the face of the column flange M = 4.17 x 0.0228
= 0.10 kN-m
Sectional modulas required S = M / fy
= 0.1 x 10^6
165
= 576.18 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 576.18
157.60
= 4.68 mm
Thickness of base plate required = 6.03 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 7.32 kN
Shear force on one bolt = 7.32 / 4
= 1.83 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 157
= 25120 N
Allowable shear strength of bolt = 25.12 kN > 1.83 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 8.34 kN
Tensile strength of one bolt Pt,allow = 30.14 kN
Shear force on one bolt FR,act = 1.83 kN
Shear strength of one bolt FR,allow = 25.12 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
8.34 1.83
+ = 0.35 < 1.40
30.14 25.12
Safe
Summary
Allowable
Sl.No Description Unit Calculated (or) Result
Provided
1 Bearing pressure on concrete base N/mm2 0.38 16 SAFE
2 Thickness of base plate mm 6.03 16 SAFE
3 Check for Tensile force per bolt KN 8.34 30.14 SAFE
4 Check for Shear force per bolt KN 1.831 25.12 SAFE
5 Check for combined Shear and Tension per bolt Safe factor 0.35 1.40 SAFE
6 Length of anchor bolt mm 65.61 300 SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 403 1.35DL+1.5WL(+X)SU
Axial load Pc = 120.69 kN Max Tension = 41.56 kN
Moment about Z - Z Mzz = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along - Z direction Fz = 33.84 kN
Shear force along - X direction Fx = 19.62 kN
Resultant shear force FR = 39.12 kN
Geometrical data
Size of the column UC 203x203x71
Length of base plate D = 250 mm
Breadth of base plate B = 250 mm
Distance between bolts along - X direction d = 100 mm
Distance between bolts along - Z direction b = 100 mm
Distance between C.L of column and bolt in tension f = 50 mm
Diameter of anchor bolt selected Ø = 20 mm
Net area of anchor bolt (From steel detailers manual) = 245 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 4
Total area of anchor bolts under tension As = 980 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0 / 120.69
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 980 (50 + 0)
250
= 12049.18
K3 = - K2 (D / 2 + f)
= - 12049.18 x (250 / 2 + 50)
= -2108606.56
Y3 + -375.00 Y2 + 12049.18 Y + -2108606.56 = 0
Solving this equation, = 0
Y = 357.7951
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 357.80
- - 0.00
2 3
= - 41.56 250 357.80
- + 50
2 3
= Not Required kN
Tensile force on one bolt = 41.56 / 4
= 10.39 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 47.04 kN > 10.39 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 120.69 x 10^3 + 0 x 10^3 )
=
250 x 250
= 1.93 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 1.93 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 203 mm
Depth of the column along - Z direction = 203 mm
Projected length of base plate from the face of the column
along - X direction a = (250 - 203) / 2
= 23.50 mm
Projected length of base plate from the face of the column
along - Z direction b = (250 - 203) / 2
= 23.50 mm
Maximum projected length c = 23.50 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 23.50 x 3 x 1.93
165
= 4.40 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 10.39 kN
Moment arm = (203 - 100) / 2
= 51.50 mm
= 0.052 m
Moment at the face of the column flange M = 10.39 x 0.0515
= 0.54 kN-m
Sectional modulas required S = M / fy
= 0.54 x 10^6
165
= 3242.94 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 3242.94
203.00
= 9.79 mm
Thickness of base plate required = 9.79 mm
Hence provide base plate of thickness = 20 mm
Check for shear
Resultant shear force FR = 39.12 kN
Shear force on one bolt = 39.12 / 4
= 9.78 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 245
= 39200 N
Allowable shear strength of bolt = 39.20 kN > 9.78 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 10.39 kN
Tensile strength of one bolt Pt,allow = 47.04 kN
Shear force on one bolt FR,act = 9.78 kN
Shear strength of one bolt FR,allow = 39.20 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
10.39 9.78
+ = 0.47 < 1.40
47.04 39.20
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
Pc
f e
Pt σc
b B X
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 407 1.35DL+1.5WL (+Z)SU
Axial load Pc = 48.31 kN Max Tension = 86.31 kN
Moment about Z - Z Mzz = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m 97
Shear force along - Z direction Fz = 49.29 kN
Shear force along - X direction Fx = 24.85 kN
Resultant shear force FR = 55.20 kN
Geometrical data
Size of the column UB 203x133x30
Length of base plate D = 250 mm
Breadth of base plate B = 250 mm
Distance between bolts along - X direction d = 100 mm
Distance between bolts along - Z direction b = 100 mm
Distance between C.L of column and bolt in tension f = 50 mm
Diameter of anchor bolt selected Ø = 20 mm
Net area of anchor bolt (From steel detailers manual) = 245 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 4
Total area of anchor bolts under tension As = 980 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0 / 48.31
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 980 (50 + 0)
250
= 12049.18
K3 = - K2 (D / 2 + f)
= - 12049.18 x (250 / 2 + 50)
= -2108606.56
Y3 + -375.00 Y2 + 12049.18 Y + -2108606.56 = 0
Solving this equation, = 0
Y = 357.7951
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 357.80
- - 0.00
2 3
= - 86.31 250 357.80
- + 50
2 3
= Not Required kN
Tensile force on one bolt = 86.31 / 4
= 21.58 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 47.04 kN > 21.58 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 48.31 x 10^3 + 0 x 10^3 )
=
250 x 250
= 0.77 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.77 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 203 mm
Depth of the column along - Z direction = 133 mm
Projected length of base plate from the face of the column
along - X direction a = (250 - 203) / 2
= 23.50 mm
Projected length of base plate from the face of the column
along - Z direction b = (250 - 133) / 2
= 58.50 mm
Maximum projected length c = 58.50 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 58.50 x 3 x 0.77
165
= 6.94 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 21.58 kN
Moment arm = (203 - 100) / 2
= 51.50 mm
= 0.052 m
Moment at the face of the column flange M = 21.58 x 0.0515
= 1.11 kN-m
Sectional modulas required S = M / fy
= 1.11 x 10^6
165
= 6734.80 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 6734.8
133.00
= 17.43 mm
Thickness of base plate required = 17.43 mm
Hence provide base plate of thickness = 25 mm
Check for shear
Resultant shear force FR = 55.20 kN
Shear force on one bolt = 55.2 / 4
= 13.80 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 245
= 39200 N
Allowable shear strength of bolt = 39.20 kN > 13.80 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 21.58 kN
Tensile strength of one bolt Pt,allow = 47.04 kN
Shear force on one bolt FR,act = 13.80 kN
Shear strength of one bolt FR,allow = 39.20 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
21.58 13.80
+ = 0.81 < 1.40
47.04 39.20
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
Pt σc
D
CONTRACT NO: - GC09102200
PROJECT TITLE: - EPIC OF SWEET FUEL GAS SUPPLY TO DUKHAN CONSUMERS
b B X
Z
Design data
Geometrical data
Eccentricity e = MR / Pc
= 24.67 / 20.5
= 1.20 m
= 1203.49 mm
D/6 = 500 / 6
= 83.3333 mm
e > D/6
Since e > D/6 anchor bolts are required to take tensile force
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (1203.49 - 500 / 2)
= 2860.46
K2 = 6 m As (f + e)
B
= 6 x 7.22 x 706 (210 + 1203.49)
500
= 86434.05
K3 = - K2 (D / 2 + f)
= - 86434.05 x (500 / 2 + 210)
= -39759661.76
CONTRACT NO: - GC09102200
PROJECT TITLE: - EPIC OF SWEET FUEL GAS SUPPLY TO DUKHAN CONSUMERS
500 102.17
- - 1203.49
2 3
= - 20.50 500 102.17
- + 210
2 3
= 47.52 kN
Tensile force on one bolt = 47.52 / 2
= 23.76 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt (Proof load) = 78.20 kN > 23.76 kN
Safe
Bearing pressure on the concrete base
= 124.62 mm
Provide anchor bolt to a length = 400 mm
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
Horizontal Resultant
Z mm mm
0.001 0.784
0.824 0.827
0.417 0.418
11.135 11.136
11.135 11.136
-0.041 0.672
11.135 11.136
-0.041 0.672
1.055 1.059
-0.008 0.660
-0.031 0.753
-0.041 0.675
11.135 11.136
Horizontal Vertical Horizontal Moment
L/C Fx kN Fy kN Fz kN Mx kNm My kNm
201 1.35DL+1.5LL 0.040 13.404 0.075 0.082 0.000
202 1.35DL+1.5WL(+X) -3.025 2.640 0.024 0.021 0.002
203 1.35DL+1.5WL(+Z) 0.010 -16.679 -0.875 -0.781 0.000
204 1.35DL+1.5LL+0.75WL(+X) -1.478 11.802 0.068 0.074 0.001
205 1.35DL+1.5LL+0.75WL(+Z) 0.039 2.142 -0.381 -0.327 0.000
206 1.35DL+1.05LL+1.5WL(+X) -3.004 7.932 0.050 0.052 0.002
207 1.35DL+1.05LL+1.5WL(+Z) 0.031 -11.387 -0.849 -0.750 0.000
201 1.35DL+1.5LL -0.040 10.255 0.046 0.056 0.000
202 1.35DL+1.5WL(+X) -2.938 7.673 0.032 0.040 0.000
203 1.35DL+1.5WL(+Z) -0.010 -10.929 -0.750 -0.619 0.000
204 1.35DL+1.5LL+0.75WL(+X) -1.504 11.857 0.053 0.064 0.000
205 1.35DL+1.5LL+0.75WL(+Z) -0.040 2.556 -0.338 -0.265 0.000
206 1.35DL+1.05LL+1.5WL(+X) -2.959 11.723 0.051 0.063 0.000
207 1.35DL+1.05LL+1.5WL(+Z) -0.031 -6.879 -0.731 -0.596 0.000
201 1.35DL+1.5LL 0.040 13.749 -0.075 0.091 0.000
202 1.35DL+1.5WL(+X) -3.058 2.733 -0.024 0.029 0.020
203 1.35DL+1.5WL(+Z) 0.011 28.537 -7.297 -0.785 0.000
204 1.35DL+1.5LL+0.75WL(+X) -1.494 12.110 -0.068 0.082 0.010
205 1.35DL+1.5LL+0.75WL(+Z) 0.040 25.012 -3.705 -0.325 0.000
206 1.35DL+1.05LL+1.5WL(+X) -3.037 8.149 -0.050 0.060 0.020
207 1.35DL+1.05LL+1.5WL(+Z) 0.032 33.953 -7.323 -0.754 0.000
201 1.35DL+1.5LL -0.040 10.477 -0.046 0.056 0.000
202 1.35DL+1.5WL(+X) -2.949 7.839 -0.032 0.040 0.000
203 1.35DL+1.5WL(+Z) -0.011 19.956 -5.838 -0.624 0.000
204 1.35DL+1.5LL+0.75WL(+X) -1.509 12.117 -0.053 0.064 0.000
205 1.35DL+1.5LL+0.75WL(+Z) -0.040 18.175 -2.956 -0.268 0.000
206 1.35DL+1.05LL+1.5WL(+X) -2.970 11.981 -0.051 0.063 0.000
207 1.35DL+1.05LL+1.5WL(+Z) -0.031 24.098 -5.857 -0.601 0.000
Mz kNm
-0.047
3.490
-0.005
1.704
-0.043
3.466
-0.029
0.041
3.447
0.018
1.759
0.045
3.469
0.039
-0.048
3.545
-0.019
1.731
-0.051
3.521
-0.043
0.041
3.462
0.006
1.766
0.038
3.483
0.027
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 205 : 1.35DL+1.5L+0.75WL(+Z)
Axial load Pc = 21.37 kN Max Tension = 0.46 kN
Moment about Z - Z Mzz = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along - Z direction Fz = 1.00 kN
Shear force along - X direction Fx = 4.49 kN
Resultant shear force FR = 4.60 kN
Geometrical data
Size of the column CH 150 X 75X18
Length of base plate D = 300 mm
Breadth of base plate B = 250 mm
Distance between bolts along - X direction d = 220 mm 0
Distance between bolts along - Z direction b = 170 mm
Distance between C.L of column and bolt in tension f = 110 mm
Diameter of anchor bolt selected Ø = 20 mm
Net area of anchor bolt (From steel detailers manual) = 245 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 490 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0 / 21.37
= 0.00 m
= 0.00 mm
D/6 = 300 / 6
= 50.00 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 300 / 2)
= -450.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 490 (110 + 0)
250
= 13254.10
K3 = - K2 (D / 2 + f)
= - 13254.1 x (300 / 2 + 110)
= -3446065.57
Y3 + -450.00 Y2 + 13254.10 Y + -3446065.57 = 0
Solving this equation, = 0
Y = 437.7062
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
300 437.71
- - 0.00
2 3
= - 0.46 300 437.71
- + 110
2 3
= Not Required kN
Tensile force on one bolt = 0.459 / 2
= 0.23 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 47.04 kN > 0.23 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 21.369 x 10^3 + 0 x 10^3 )
=
300 x 250
= 0.28 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.28 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 150 mm
Depth of the column along - Z direction = 75 mm
Projected length of base plate from the face of the column
along - X direction a = (300 - 150) / 2
= 75.00 mm
Projected length of base plate from the face of the column
along - Z direction b = (250 - 75) / 2
= 87.50 mm
Maximum projected length c = 87.50 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 87.50 x 3 x 0.28
165
= 6.30 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 0.11 kN
Moment arm = (150 - 220) / 2
= 35.00 mm
= 0.035 m
Moment at the face of the column flange M = 0.11 x 0.035
= 0.00 kN-m
Sectional modulas required S = M / fy
= 0 x 10^6
165
= 24.34 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 24.34
75.00
= 1.40 mm
Thickness of base plate required = 6.30 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 4.60 kN
Shear force on one bolt = 4.6 / 4
= 1.15 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 245
= 39200 N
Allowable shear strength of bolt = 39.20 kN > 1.15 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 0.23 kN
Tensile strength of one bolt Pt,allow = 47.04 kN
Shear force on one bolt FR,act = 1.15 kN
Shear strength of one bolt FR,allow = 39.20 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
0.23 1.15
+ = 0.03 < 1.40
47.04 39.20
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 204 1.35DL+1.5L+0.75WL(+Z)
Axial load Pc = 0.00 kN Max Tension = 3.24 kN
Moment about Z-Z MZZ = 0.05 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.05 kN-m
Shear force along -Z direction FZ = 0.29 kN
Shear force along - X direction Fx = 0.03 kN
Resultant shear force FR = 0.29 kN
Geometrical data
Size of the column CH 150 X 75X18
Length of base plate D = 200 mm
Breadth of base plate B = 200 mm
Distance between bolts along - X direction d = 70 mm
Distance between bolts along - Z direction b = 140 mm
Distance between C.L of column and bolt in tension f = 35 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0.05 / 0
= 0.00 m
= 0.00 mm
D/6 = 200 / 6
= 33.33 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 200 / 2)
= -300.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (35 + 0)
200
= 3378.07
K3 = - K2 (D / 2 + f)
= - 3378.07 x (200 / 2 + 35)
= -456039.96
Y3 + -300.00 Y2 + 3378.07 Y + -456039.96 = 0
Solving this equation, = 0
Y = 293.79
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
200 293.79
- - 0.00
2 3
= - 3.24 200 293.79
- + 35
2 3
= Not Required kN
Tensile force on one bolt = 3.24 / 2
= 1.62 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 30.14 kN > 1.62 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 0 x 10^3 + 0 x 10^3 )
=
200 x 200
= 0.00 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.00 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 150 mm
Depth of the column along - Z direction = 75 mm
Projected length of base plate from the face of the column
along - X direction a = (200 - 150) / 2
= 25.00 mm
Projected length of base plate from the face of the column
along - Z direction b = (200 - 75) / 2
= 62.50 mm
Maximum projected length c = 62.50 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 62.50 x 3 x 0.00
165
= 0.00 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 0.81 kN
Moment arm = (150 - 70) / 2
= 40.00 mm
= 0.040 m
Moment at the face of the column flange M = 0.81 x 0.04
= 0.03 kN-m
Sectional modulas required S = M / fy
= 0.03 x 10^6
165
= 196.36 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 196.36
75.00
= 3.96 mm
Thickness of base plate required = 3.96 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 0.29 kN
Shear force on one bolt = 0.29 / 4
= 0.07 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 157
= 25120 N
Allowable shear strength of bolt = 25.12 kN > 0.07 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 1.62 kN
Tensile strength of one bolt Pt,allow = 30.14 kN
Shear force on one bolt FR,act = 0.07 kN
Shear strength of one bolt FR,allow = 25.12 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
1.62 0.07
+ = 0.06 < 1.40
30.14 25.12
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 205 1.35DL+1.5L+0.75WL(+Z)
Axial load Pc = 9.60 kN Max Tension = 4.50 kN
Moment about Z-Z MZZ = 0.23 kN-m
Moment about X - X Mxx = 0.23 kN-m
Resultant moment MR = 0.32 kN-m
Shear force along -Z direction FZ = 7.00 kN
Shear force along - X direction Fx = 6.70 kN
Resultant shear force FR = 9.69 kN
Geometrical data
Size of the column CH 150 X 75X18
Length of base plate D = 250 mm
Breadth of base plate B = 170 mm
Distance between bolts along - X direction d = 0 mm 0
Distance between bolts along - Z direction b = 90 mm
Distance between C.L of column and bolt in tension f = 0 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 2
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0.32 / 9.6
= 0.03 m
= 33.81 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (33.81 - 250 / 2)
= -273.57
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (0 + 33.81)
170
= 3839.25
K3 = - K2 (D / 2 + f)
= - 3839.25 x (250 / 2 + 0)
= -479906.75
Y3 + -273.57 Y2 + 3839.25 Y + -479906.75 = 0
Solving this equation, = 0
Y = 265.9
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 265.91
- - 33.81
2 3
= - 4.50 250 265.91
- + 0
2 3
= Not Required kN
Tensile force on one bolt = 4.5 / 2
= 2.25 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 30.14 kN > 2.25 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 9.601 x 10^3 + 0 x 10^3 )
=
250 x 170
= 0.23 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.23 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 150 mm
Depth of the column along - Z direction = 75 mm
Projected length of base plate from the face of the column
along - X direction a = (250 - 150) / 2
= 50.00 mm
Projected length of base plate from the face of the column
along - Z direction b = (170 - 75) / 2
= 47.50 mm
Maximum projected length c = 50.00 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 50.00 x 3 x 0.23
165
= 3.20 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 2.25 kN
Moment arm = (150 - 0) / 2
= 75.00 mm
= 0.075 m
Moment at the face of the column flange M = 2.25 x 0.075
= 0.17 kN-m
Sectional modulas required S = M / fy
= 0.17 x 10^6
165
= 1022.73 mm3
Thickness of plate required t = 6S/L
0.50
= 6 x 1022.73
75.00
= 9.05 mm
Thickness of base plate required = 9.05 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 9.69 kN
Shear force on one bolt = 9.69 / 2
= 4.84 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 157
= 25120 N
Allowable shear strength of bolt = 25.12 kN > 4.84 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 2.25 kN
Tensile strength of one bolt Pt,allow = 30.14 kN
Shear force on one bolt FR,act = 4.84 kN
Shear strength of one bolt FR,allow = 25.12 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
2.25 4.84
+ = 0.27 < 1.40
30.14 25.12
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 204 1.35DL+1.5L+0.75WL(+Z)
Axial load Pc = 10.95 kN Max Tension = 0.00 kN
Moment about Z-Z MZZ = 0.23 kN-m
Moment about X - X Mxx = 0.29 kN-m
Resultant moment MR = 0.37 kN-m
Shear force along -Z direction FZ = 7.04 kN
Shear force along - X direction Fx = 7.31 kN
Resultant shear force FR = 10.15 kN
Geometrical data
Size of the column CH 150 X 75X18
Length of base plate D = 250 mm
Breadth of base plate B = 150 mm
Distance between bolts along - X direction d = 0 mm
Distance between bolts along - Z direction b = 90 mm
Distance between C.L of column and bolt in tension f = 0 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 2
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0.37 / 10.95
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (0 + 0)
150
= 0.00
K3 = - K2 (D / 2 + f)
= - 0 x (250 / 2 + 0)
= 0.00
Y3 + -375.00 Y2 + 0.00 Y + 0.00 = 0
Solving this equation, = 0
Y = 375.00
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 375.00
- - 0.00
2 3
= - 0.00 250 375.00
- + 0
2 3
= Not Required kN
Tensile force on one bolt = 0/2
= 0.00 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 30.14 kN > 0.00 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 10.95 x 10^3 + 0 x 10^3 )
=
250 x 150
= 0.29 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.29 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 150 mm
Depth of the column along - Z direction = 75 mm
Projected length of base plate from the face of the column
along - X direction a = (250 - 150) / 2
= 50.00 mm
Projected length of base plate from the face of the column
along - Z direction b = (150 - 75) / 2
= 37.50 mm
Maximum projected length c = 50.00 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 50.00 x 3 x 0.29
165
= 3.64 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 0.00 kN
Moment arm = (150 - 0) / 2
= 75.00 mm
= 0.075 m
Moment at the face of the column flange M = 0 x 0.075
= 0.00 kN-m
Sectional modulas required S = M / fy
= 0 x 10^6
165
= 0.00 mm3
Thickness of plate required t = 6S/L
0.50
= 6x0
75.00
= 0.00 mm
Thickness of base plate required = 3.64 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 10.15 kN
Shear force on one bolt = 10.15 / 2
= 5.08 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 157
= 25120 N
Allowable shear strength of bolt = 25.12 kN > 5.08 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 0.00 kN
Tensile strength of one bolt Pt,allow = 30.14 kN
Shear force on one bolt FR,act = 5.08 kN
Shear strength of one bolt FR,allow = 25.12 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
0.00 5.08
+ = 0.20 < 1.40
30.14 25.12
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 25 N/mm2
Allowable bearing pressure on concrete σc = 10 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 25 Ec = 20005 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 201 1.35DL+1.5L
Axial load Pc = 0.00 kN Max Tension = 9.00 kN
Moment about Z-Z MZZ = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along -Z direction FZ = 21.42 kN
Shear force along - X direction Fx = 8.80 kN
Resultant shear force FR = 23.16 kN
Geometrical data
Length of base plate D = 250 mm
Breadth of base plate B = 150 mm
Distance between bolts along - X direction d = 110 mm
Distance between bolts along - Z direction b = 160 mm
Distance between C.L of column and bolt in tension f = 55 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 4
Total area of anchor bolts under tension As = 628 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0/0
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 628 (55 + 0)
150
= 14157.86
K3 = - K2 (D / 2 + f)
= - 14157.86 x (250 / 2 + 55)
= -2548414.90
Y3 + -375.00 Y2 + 14157.86 Y + -2548414.90 = 0
Solving this equation, = 0
Y = 355.34
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 355.34
- - 0.00
2 3
= - 9.00 250 355.34
- + 55
2 3
= Not Required kN
Tensile force on one bolt = 9/4
= 2.25 kN
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 40 N/mm2
Allowable bearing pressure on concrete σc = 16 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 40 Ec = 20008 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 204 1.35DL+1.5L+0.75WL(+Z)
Axial load Pc = 18.00 kN Max Tension = 0.00 kN
Moment about Z-Z MZZ = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along -Z direction FZ = 7.04 kN
Shear force along - X direction Fx = 7.31 kN
Resultant shear force FR = 10.15 kN
Geometrical data
Size of the column CH 150 X 75X18
Length of base plate D = 250 mm
Breadth of base plate B = 150 mm
Distance between bolts along - X direction d = 0 mm
Distance between bolts along - Z direction b = 90 mm
Distance between C.L of column and bolt in tension f = 0 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt (From steel detailers manual) = 157 mm2
Total number of anchor bolts provided = 2
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0 / 18
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (0 + 0)
150
= 0.00
K3 = - K2 (D / 2 + f)
= - 0 x (250 / 2 + 0)
= 0.00
Y3 + -375.00 Y2 + 0.00 Y + 0.00 = 0
Solving this equation, = 0
Y = 375.00
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 375.00
- - 0.00
2 3
= - 0.00 250 375.00
- + 0
2 3
= Not Required kN
Tensile force on one bolt = 0/2
= 0.00 kN
Allowable tensile stress on bolt (Table 34 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable tensile stress on bolt (Bolt grade 4.6) = 240 N/mm2
Allowable tensile strength of bolt = 30.14 kN > 0.00 kN
Safe
Bearing pressure on the concrete base
Bearing pressure on the concrete base σc = 2 (Pc + Pt) Or Pc
YB DB
1 x ( 18 x 10^3 + 0 x 10^3 )
=
250 x 150
= 0.48 N/mm2
Allowable bearing pressure on concrete base = 16.00 N/mm2 > 0.48 N/mm2
Safe
Thickness of base plate
(i) Based on the bearing pressure below the base plate
Depth of the column along - X direction = 150 mm
Depth of the column along - Z direction = 75 mm
Projected length of base plate from the face of the column
along - X direction a = (250 - 150) / 2
= 50.00 mm
Projected length of base plate from the face of the column
along - Z direction b = (150 - 75) / 2
= 37.50 mm
Maximum projected length c = 50.00 mm
Design strength of base plate fy = 165 N/mm2 ( 0.6 x S 275)
Thickness of base plate t = c 3 σc / fy
0.50
= 50.00 x 3 x 0.48
165
= 4.67 mm
(ii) Based on the bolt tension
Tensile force on bolts on one side = 0.00 kN
Moment arm = (150 - 0) / 2
= 75.00 mm
= 0.075 m
Moment at the face of the column flange M = 0 x 0.075
= 0.00 kN-m
Sectional modulas required S = M / fy
= 0 x 10^6
165
= 0.00 mm3
Thickness of plate required t = 6S/L
0.50
= 6x0
75.00
= 0.00 mm
Thickness of base plate required = 4.67 mm
Hence provide base plate of thickness = 16 mm
Check for shear
Resultant shear force FR = 10.15 kN
Shear force on one bolt = 10.15 / 2
= 5.08 kN
Allowable shear stress on bolt (Table 30 of BS 5950 - 1, 2000)
Grade of bolt = 4.6
Allowable shear stress on bolt = 160 N/mm2
Allowable shear strength of bolt = 160 x 157
= 25120 N
Allowable shear strength of bolt = 25.12 kN > 5.08 kN
Safe
Check for shear and tension
Tensile force on one bolt Pt,act = 0.00 kN
Tensile strength of one bolt Pt,allow = 30.14 kN
Shear force on one bolt FR,act = 5.08 kN
Shear strength of one bolt FR,allow = 25.12 kN
Pt,act FR,act
+ ≤ 1.40
Pt,allow FR,allow
0.00 5.08
+ = 0.20 < 1.40
30.14 25.12
Safe
Summary
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 25 N/mm2
Allowable bearing pressure on concrete σc = 10 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 25 Ec = 20005 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 201 1.35DL+1.5L
Axial load Pc = 9.00 kN Max Tension = 0.00 kN
Moment about Z-Z MZZ = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along -Z direction FZ = 21.42 kN
Shear force along - X direction Fx = 8.80 kN
Resultant shear force FR = 23.16 kN
Geometrical data
Length of base plate D = 250 mm
Breadth of base plate B = 300 mm
Distance between bolts along - X direction d = 110 mm
Distance between bolts along - Z direction b = 160 mm
Distance between C.L of column and bolt in tension f = 55 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt = 157 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 4
Total area of anchor bolts under tension As = 628 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0/9
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 628 (55 + 0)
300
= 7078.93
K3 = - K2 (D / 2 + f)
= - 7078.93 x (250 / 2 + 55)
= -1274207.45
Y3 + -375.00 Y2 + 7078.93 Y + -1274207.45 = 0
Solving this equation, = 0
Y = 365.17
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 365.17
- - 0.00
2 3
= - 0.00 250 365.17
- + 55
2 3
= Not Required kN
Tensile force on one bolt = 0/4
= 0.00 kN
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 25 N/mm2
Allowable bearing pressure on concrete σc = 10 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 25 Ec = 20005 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 201 1.35DL+1.5L
Axial load Pc = 0.00 kN Max Tension = 9.00 kN
Moment about Z-Z MZZ = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along -Z direction FZ = 21.42 kN
Shear force along - X direction Fx = 8.80 kN
Resultant shear force FR = 23.16 kN
Geometrical data
Length of base plate D = 250 mm
Breadth of base plate B = 300 mm
Distance between bolts along - X direction d = 110 mm
Distance between bolts along - Z direction b = 160 mm
Distance between C.L of column and bolt in tension f = 55 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt = 157 mm2
Total number of anchor bolts provided = 4
No of anchor bolts on one side under tension = 4
Total area of anchor bolts under tension As = 628 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0/0
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 628 (55 + 0)
300
= 7078.93
K3 = - K2 (D / 2 + f)
= - 7078.93 x (250 / 2 + 55)
= -1274207.45
Y3 + -375.00 Y2 + 7078.93 Y + -1274207.45 = 0
Solving this equation, = 0
Y = 365.17
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 365.17
- - 0.00
2 3
= - 9.00 250 365.17
- + 55
2 3
= Not Required kN
Tensile force on one bolt = 9/4
= 2.25 kN
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
DESIGN OF BASE PLATE & ANCHOR BOLT
Pc
f e
Pt σc
b B X
D
Z
Design data
Grade of concrete fck = 25 N/mm2
Allowable bearing pressure on concrete σc = 10 N/mm2
Modulas of elasticity for steel Es = 205000 N/mm2
Modulas of elasticity for concrete of grade C 25 Ec = 20005 N/mm2
Modular ratio Es / Ec m = 10.25
Load data corresponding to critical load combination no 208 1.35DL 201 1.35DL+1.5L
Axial load Pc = 10.99 kN Max Tension = 1.48 kN
Moment about Z-Z MZZ = 0.00 kN-m
Moment about X - X Mxx = 0.00 kN-m
Resultant moment MR = 0.00 kN-m
Shear force along -Z direction FZ = 0.23 kN
Shear force along - X direction Fx = 1.69 kN
Resultant shear force FR = 1.70 kN
Geometrical data
Length of base plate D = 250 mm
Breadth of base plate B = 200 mm
Distance between bolts along - X direction d = 0 mm
Distance between bolts along - Z direction b = 120 mm
Distance between C.L of column and bolt in tension f = 0 mm
Diameter of anchor bolt selected Ø = 16 mm
Net area of anchor bolt = 157 mm2
Total number of anchor bolts provided = 2
No of anchor bolts on one side under tension = 2
Total area of anchor bolts under tension As = 314 mm2
Tensile force on bolts
Eccentricity e = MR / Pc
= 0 / 10.99
= 0.00 m
= 0.00 mm
D/6 = 250 / 6
= 41.67 mm
e < D/6
No varying pressure
Effective bearing length of base plate = Y
Y3 + K1 Y2 + K2 Y + K3 = 0
K1 = 3 (e - D/2)
= 3 x (0 - 250 / 2)
= -375.00
K2 = 6 m As (f + e)
B
= 6 x 10.25 x 314 (0 + 0)
200
= 0.00
K3 = - K2 (D / 2 + f)
= - 0 x (250 / 2 + 0)
= 0.00
Y3 + -375.00 Y2 + 0.00 Y + 0.00 = 0
Solving this equation, = 0
Y = 375.00
D Y
- - e
2 3
Pt = - Pc
D Y
- + f
2 3
250 375.00
- - 0.00
2 3
= - 1.48 250 375.00
- + 0
2 3
= Not Required kN
Tensile force on one bolt = 1.476 / 2
= 0.74 kN
Allowable (or)
Sl.No Description Unit Calculated Result
Provided
SAFE
SAFE
SAFE
SAFE
SAFE
Horizontal Vertical Horizontal Resultant