You are on page 1of 70

SR.

PARTICULARS CRITERIA UNIT


NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 45 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 45


2 PEAK FLOW Cum/Day 135
3 DESIGN FLOW Cum/hr 5.625

A AERATION TANK
1 BOD LOAD 13.50
3 VOLUME 33.75
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 24.30
7 HP OF AERATOR 0.68
8 CHECK FOR AERATOR POWER FOR MIXING 0.50
MINIMUM POWER REQUIRED - KW 0.51
MAXIMUM POWER REQUIRED - KW 0.88
9 AIR REQUIRED 1822.5
10 LIQUID DEPTH OF AERATION TANK 2.90
11 AREA OF AERATION TANK 11.64
12 WIDTH OF AERATION TANK 2.12 2.12
13 LENGTH OF AERATION TANK 5.49 5.49
14 AREA OF AERATION TANK PROVIDED 11.64 11.64
15 CFM REQUIRED FOR BLOWER 20 HRS 54.24
16 HRS 67.80
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2900

B SETTLING TANK
1 AREA OF SETTLING TANK 9.00
2 WIDTH OF SETTLING TANK REQUIRED 2.12 2.125
3 LENGTH OF SETTLING TANK REQUIRED 4.24 4.25
4 AREA OF SETTLING TANK PROVIDED 9.00 9.03
5 SIZE OF SLUDGE PIT 0.50
6 DEPTH OF SLUDGE PIT 0.20
7 DEPTH OF HOPPER PORTION 0.91
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.60
8 SOLIDS LOAD 540
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 540
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 84.375

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 1.35
2 LIQUID VOLUME 1.35
3 VOLUME OF SDB 1.35
4 AREA OF SDB 4.50
5 NOS. OF SDB 2
6 AREA OF EACH SDB 2.25
7 WIDTH OF SDB 1.06 1.06
8 LENGTH OF SDB 2.12 2.12
9 AREA PROVIDED PER BED 2.3 2.3
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 25 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 25


2 PEAK FLOW Cum/Day 75
3 DESIGN FLOW Cum/hr 3.125

A AERATION TANK
1 BOD LOAD 5.00
3 VOLUME 12.50
4 CHECK FOR HRT 12.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 9.00
7 HP OF AERATOR 0.25
8 CHECK FOR AERATOR POWER FOR MIXING 0.19
MINIMUM POWER REQUIRED - KW 0.19
MAXIMUM POWER REQUIRED - KW 0.33
9 AIR REQUIRED 675
10 LIQUID DEPTH OF AERATION TANK 3.00
11 AREA OF AERATION TANK 4.17
12 WIDTH OF AERATION TANK 1.80 1.80
13 LENGTH OF AERATION TANK 2.31 2.31
14 AREA OF AERATION TANK PROVIDED 4.17 4.17
15 CFM REQUIRED FOR BLOWER 20 HRS 20.09
16 HRS 25.11
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3000

B SETTLING TANK
1 AREA OF SETTLING TANK 5.00
2 WIDTH OF SETTLING TANK REQUIRED 1.58 1.58
3 LENGTH OF SETTLING TANK REQUIRED 3.16 3.16
4 AREA OF SETTLING TANK PROVIDED 5.00 5.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.64
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.30
8 SOLIDS LOAD 300
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 300
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 46.875

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 0.50
2 LIQUID VOLUME 0.50
3 VOLUME OF SDB 0.50
4 AREA OF SDB 1.67
5 NOS. OF SDB 2
6 AREA OF EACH SDB 0.83
7 WIDTH OF SDB 0.65 0.65
8 LENGTH OF SDB 1.29 1.29
9 AREA PROVIDED PER BED 0.8 0.8
DESIGN
PURPOSE
0.10
4000
200
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 110


2 PEAK FLOW Cum/Day 330
3 DESIGN FLOW Cum/hr 13.75

A AERATION TANK
1 BOD LOAD 33.00
3 VOLUME 82.50
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 59.40
7 HP OF AERATOR 1.65
8 CHECK FOR AERATOR POWER FOR MIXING 1.23
MINIMUM POWER REQUIRED - KW 1.24
MAXIMUM POWER REQUIRED - KW 2.15
9 AIR REQUIRED 4455
10 LIQUID DEPTH OF AERATION TANK 2.80 2.80
11 AREA OF AERATION TANK 29.46
12 WIDTH OF AERATION TANK 2.10 2.10
13 LENGTH OF AERATION TANK 14.05 14.05
14 AREA OF AERATION TANK PROVIDED 29.46 29.46
15 CFM REQUIRED FOR BLOWER 20 HRS 132.59
16 HRS 165.74
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2800

B SETTLING TANK
1 AREA OF SETTLING TANK 22.00
2 WIDTH OF SETTLING TANK REQUIRED 2.10 2.10
3 LENGTH OF SETTLING TANK REQUIRED 10.49 10.49
4 AREA OF SETTLING TANK PROVIDED 22.00 22.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.90
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.50 2.50
8 SOLIDS LOAD 1320
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 1320
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 206.25

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 3.30
2 LIQUID VOLUME 3.30
3 VOLUME OF SDB 3.30
4 AREA OF SDB 11.00
5 NOS. OF SDB 6
6 AREA OF EACH SDB 1.83
7 WIDTH OF SDB 0.96 0.96
8 LENGTH OF SDB 1.91 1.91
9 AREA PROVIDED PER BED 1.8 1.8
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 30 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 108


2 PEAK FLOW Cum/Day 324
3 DESIGN FLOW Cum/hr 13.5

A AERATION TANK
1 BOD LOAD 32.40
3 VOLUME 81.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 58.32
7 HP OF AERATOR 1.62
8 CHECK FOR AERATOR POWER FOR MIXING 1.21
MINIMUM POWER REQUIRED - KW 1.22
MAXIMUM POWER REQUIRED - KW 2.11
9 AIR REQUIRED 4374
10 LIQUID DEPTH OF AERATION TANK 3.40 3.10
11 AREA OF AERATION TANK 23.82
12 WIDTH OF AERATION TANK 3.29 2.95
13 LENGTH OF AERATION TANK 7.25 8.10
14 AREA OF AERATION TANK PROVIDED 23.82 23.90
15 CFM REQUIRED FOR BLOWER 20 HRS 130.18
16 HRS 162.72
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3400

B SETTLING TANK
1 AREA OF SETTLING TANK 21.60
2 WIDTH OF SETTLING TANK REQUIRED 3.29 2.70
3 LENGTH OF SETTLING TANK REQUIRED 6.57 8.10
4 AREA OF SETTLING TANK PROVIDED 21.60 21.87
5 SIZE OF SLUDGE PIT 0.50 0.50
6 DEPTH OF SLUDGE PIT 0.20 0.20
7 DEPTH OF HOPPER PORTION 1.39 1.10
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 3.10 2.80
8 SOLIDS LOAD 1296
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 1296
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 202.5

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 3.24
2 LIQUID VOLUME 3.24
3 VOLUME OF SDB 3.24
4 AREA OF SDB 10.80
5 NOS. OF SDB 2
6 AREA OF EACH SDB 5.40
7 WIDTH OF SDB 1.64 1.64
8 LENGTH OF SDB 3.29 3.29
9 AREA PROVIDED PER BED 5.4 5.4
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 16 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 16


2 PEAK FLOW Cum/Day 48
3 DESIGN FLOW Cum/hr 2

A AERATION TANK
1 BOD LOAD 4.80
3 VOLUME 12.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 8.64
7 HP OF AERATOR 0.24
8 CHECK FOR AERATOR POWER FOR MIXING 0.18
MINIMUM POWER REQUIRED - KW 0.18
MAXIMUM POWER REQUIRED - KW 0.31
9 AIR REQUIRED 648
10 LIQUID DEPTH OF AERATION TANK 2.40 2.40
11 AREA OF AERATION TANK 5.00
12 WIDTH OF AERATION TANK 1.26 1.26
13 LENGTH OF AERATION TANK 3.95 3.95
14 AREA OF AERATION TANK PROVIDED 5.00 5.00
15 CFM REQUIRED FOR BLOWER 20 HRS 19.29
16 HRS 24.11
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2400

B SETTLING TANK
1 AREA OF SETTLING TANK 3.20
2 WIDTH OF SETTLING TANK REQUIRED 1.26 1.26
3 LENGTH OF SETTLING TANK REQUIRED 2.53 2.53
4 AREA OF SETTLING TANK PROVIDED 3.20 3.20
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.48
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.10 2.10
8 SOLIDS LOAD 192
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 192
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 30

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 0.48
2 LIQUID VOLUME 0.48
3 VOLUME OF SDB 0.48
4 AREA OF SDB 1.60
5 NOS. OF SDB 2
6 AREA OF EACH SDB 0.80
7 WIDTH OF SDB 0.63 0.63
8 LENGTH OF SDB 1.26 1.26
9 AREA PROVIDED PER BED 0.8 0.8
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 20


2 PEAK FLOW Cum/Day 60
3 DESIGN FLOW Cum/hr 2.5

A AERATION TANK
1 BOD LOAD 6.00
3 VOLUME 15.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 10.80
7 HP OF AERATOR 0.30
8 CHECK FOR AERATOR POWER FOR MIXING 0.22
MINIMUM POWER REQUIRED - KW 0.23
MAXIMUM POWER REQUIRED - KW 0.39
9 AIR REQUIRED 810
10 LIQUID DEPTH OF AERATION TANK 2.50 2.50
11 AREA OF AERATION TANK 6.00
12 WIDTH OF AERATION TANK 1.41 1.41
13 LENGTH OF AERATION TANK 4.24 4.24
14 AREA OF AERATION TANK PROVIDED 6.00 6.00
15 CFM REQUIRED FOR BLOWER 20 HRS 24.11
16 HRS 30.13
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2500

B SETTLING TANK
1 AREA OF SETTLING TANK 4.00
2 WIDTH OF SETTLING TANK REQUIRED 1.41 1.41
3 LENGTH OF SETTLING TANK REQUIRED 2.83 2.83
4 AREA OF SETTLING TANK PROVIDED 4.00 4.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.56
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.20 2.20
8 SOLIDS LOAD 240
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 240
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 37.5

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 0.60
2 LIQUID VOLUME 0.60
3 VOLUME OF SDB 0.60
4 AREA OF SDB 2.00
5 NOS. OF SDB 2
6 AREA OF EACH SDB 1.00
7 WIDTH OF SDB 0.71 0.71
8 LENGTH OF SDB 1.41 1.41
9 AREA PROVIDED PER BED 1.0 1.0
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 25 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 25


2 PEAK FLOW Cum/Day 75
3 DESIGN FLOW Cum/hr 3.125

A AERATION TANK
1 BOD LOAD 7.50
3 VOLUME 18.75
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 13.50
7 HP OF AERATOR 0.38
8 CHECK FOR AERATOR POWER FOR MIXING 0.28
MINIMUM POWER REQUIRED - KW 0.28
MAXIMUM POWER REQUIRED - KW 0.49
9 AIR REQUIRED 1012.5
10 LIQUID DEPTH OF AERATION TANK 2.60
11 AREA OF AERATION TANK 7.21
12 WIDTH OF AERATION TANK 1.58 1.58
13 LENGTH OF AERATION TANK 4.56 4.56
14 AREA OF AERATION TANK PROVIDED 7.21 7.21
15 CFM REQUIRED FOR BLOWER 20 HRS 30.13
16 HRS 37.67
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2600

B SETTLING TANK
1 AREA OF SETTLING TANK 5.00
2 WIDTH OF SETTLING TANK REQUIRED 1.58 1.58
3 LENGTH OF SETTLING TANK REQUIRED 3.16 3.16
4 AREA OF SETTLING TANK PROVIDED 5.00 5.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.64
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.30
8 SOLIDS LOAD 300
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 300
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 46.875

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 0.75
2 LIQUID VOLUME 0.75
3 VOLUME OF SDB 0.75
4 AREA OF SDB 2.50
5 NOS. OF SDB 2
6 AREA OF EACH SDB 1.25
7 WIDTH OF SDB 0.79 0.79
8 LENGTH OF SDB 1.58 1.58
9 AREA PROVIDED PER BED 1.3 1.3
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 30 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 30


2 PEAK FLOW Cum/Day 90
3 DESIGN FLOW Cum/hr 3.75

A AERATION TANK
1 BOD LOAD 9.00
3 VOLUME 22.50
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 16.20
7 HP OF AERATOR 0.45
8 CHECK FOR AERATOR POWER FOR MIXING 0.34
MINIMUM POWER REQUIRED - KW 0.34
MAXIMUM POWER REQUIRED - KW 0.59
9 AIR REQUIRED 1215
10 LIQUID DEPTH OF AERATION TANK 2.70
11 AREA OF AERATION TANK 8.33
12 WIDTH OF AERATION TANK 1.73 1.73
13 LENGTH OF AERATION TANK 4.81 4.81
14 AREA OF AERATION TANK PROVIDED 8.33 8.33
15 CFM REQUIRED FOR BLOWER 20 HRS 36.16
16 HRS 45.20
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2700

B SETTLING TANK
1 AREA OF SETTLING TANK 6.00
2 WIDTH OF SETTLING TANK REQUIRED 1.73 1.73
3 LENGTH OF SETTLING TANK REQUIRED 3.46 3.46
4 AREA OF SETTLING TANK PROVIDED 6.00 6.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 0.72
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.40
8 SOLIDS LOAD 360
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 360
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 56.25

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 0.90
2 LIQUID VOLUME 0.90
3 VOLUME OF SDB 0.90
4 AREA OF SDB 3.00
5 NOS. OF SDB 2
6 AREA OF EACH SDB 1.50
7 WIDTH OF SDB 0.87 0.87
8 LENGTH OF SDB 1.73 1.73
9 AREA PROVIDED PER BED 1.5 1.5
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 40 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 40


2 PEAK FLOW Cum/Day 120
3 DESIGN FLOW Cum/hr 5

A AERATION TANK
1 BOD LOAD 12.00
3 VOLUME 30.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 21.60
7 HP OF AERATOR 0.60
8 CHECK FOR AERATOR POWER FOR MIXING 0.45
MINIMUM POWER REQUIRED - KW 0.45
MAXIMUM POWER REQUIRED - KW 0.78
9 AIR REQUIRED 1620
10 LIQUID DEPTH OF AERATION TANK 2.90
11 AREA OF AERATION TANK 10.34
12 WIDTH OF AERATION TANK 2.00 2.00
13 LENGTH OF AERATION TANK 5.17 5.17
14 AREA OF AERATION TANK PROVIDED 10.34 10.34
15 CFM REQUIRED FOR BLOWER 20 HRS 48.21
16 HRS 60.27
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 2900

B SETTLING TANK
1 AREA OF SETTLING TANK 8.00
2 WIDTH OF SETTLING TANK REQUIRED 2.00 2.00
3 LENGTH OF SETTLING TANK REQUIRED 4.00 4.00
4 AREA OF SETTLING TANK PROVIDED 8.00 8.00
5 SIZE OF SLUDGE PIT 0.50
6 DEPTH OF SLUDGE PIT 0.20
7 DEPTH OF HOPPER PORTION 0.85
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.60
8 SOLIDS LOAD 480
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 480
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 75

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 1.20
2 LIQUID VOLUME 1.20
3 VOLUME OF SDB 1.20
4 AREA OF SDB 4.00
5 NOS. OF SDB 2
6 AREA OF EACH SDB 2.00
7 WIDTH OF SDB 1.00 1.00
8 LENGTH OF SDB 2.00 2.00
9 AREA PROVIDED PER BED 2.0 2.0
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

S.NO. EQUATIONS USED FOR DESIGN


A FOR AERATION TANK
1 BOD LOAD [ ORGANIC LOAD ] = [ (Q * BOD * 1000) / 1000000 ]
2 VOLUME = [ (BOD LOAD * 1000000) / (F/M RATIO * MLSS * 1000) ]
3 HRT = [ (AV. FLOW * 24) / VOLUME ] HRT SHOULD BE 12 HRS MINIMUM
4 VOLUMETRIC LOADING = [ BOD LOAD / VOLUME ]
5 OXYGEN REQUIRED = [ CONSTANT * BOD LOAD ]
6 HP OF AERATOR = [ OXYGEN REQUIRED / (OXYGEN TRANSFER CAPACITY * 24) ]
7 CHECKING AERATOR HP FOR MIXING = [ 0.015 * VOLUME ] TO [ 0.026 * VOLUME ]

B SETTLING TANK

1 AREA OF SETTLING TANK = [ PEAK FLOW / SLR ]


2 SOLIDS LOAD = [ (MLSS * Q * 1000) / 1000000 ]
3 SOLIDS LOADING = [ SOLIDS LOAD / AREA OF SETTLING TANK ]
4 WEIR LOAD = [ (MLSS * Q * 1000) / 1000000 ]
5 WEIR LOADING = [ WEIR LOAD / PERIMETER OF LAUNDER ]
C SLUDGE DRYING BEDS

1 EXCESS SLUDGE = [ BOD LOAD * CONSTANT ]


2 LIQUID VOLUME = [ EXCESS SLUDGE * 100 ]
3 VOLUME OF SDB = [ LIQUID VOLUME * SLUDGE DRYING PERIOD ]
4 AREA OF SDB = [ VOLUME OF SDB / DEPTH OF SLUDGE ]
5 L/B RATIO = 1 : 2

RADIANT PACKAGE TREATMENT PLANT - 56 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 56


2 PEAK FLOW Cum/Day 168
3 DESIGN FLOW Cum/hr 7

A AERATION TANK
1 BOD LOAD 16.80
3 VOLUME 42.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 30.24
7 HP OF AERATOR 0.84
8 CHECK FOR AERATOR POWER FOR MIXING 0.63
MINIMUM POWER REQUIRED - KW 0.63
MAXIMUM POWER REQUIRED - KW 1.09
9 AIR REQUIRED 2268
10 LIQUID DEPTH OF AERATION TANK 3.00
11 AREA OF AERATION TANK 14.00
12 WIDTH OF AERATION TANK 2.37 2.37
13 LENGTH OF AERATION TANK 5.92 5.92
14 AREA OF AERATION TANK PROVIDED 14.00 14.00
15 CFM REQUIRED FOR BLOWER 20 HRS 67.50
16 HRS 84.38
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3000
B SETTLING TANK
1 AREA OF SETTLING TANK 11.20
2 WIDTH OF SETTLING TANK REQUIRED 2.37 2.37
3 LENGTH OF SETTLING TANK REQUIRED 4.73 4.73
4 AREA OF SETTLING TANK PROVIDED 11.20 11.20
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.03
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.70
8 SOLIDS LOAD 672
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 672
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 105

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 1.68
2 LIQUID VOLUME 1.68
3 VOLUME OF SDB 1.68
4 AREA OF SDB 5.60
5 NOS. OF SDB 2
6 AREA OF EACH SDB 2.80
7 WIDTH OF SDB 1.18 1.18
8 LENGTH OF SDB 2.37 2.37
9 AREA PROVIDED PER BED 2.8 2.8
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30

ESIGN UNIT

Kg/Day
Cum
HRS MINIMUM Hrs

Kg/Day
ACITY * 24) ] HP
26 * VOLUME ] Kw/Cum

Sqm
Cum/Day
Kg/Day/Sqm
Cum/Day
Kg/Day/M
Kg
Lit/Day
Cum
Sqm
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 60 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 60


2 PEAK FLOW Cum/Day 180
3 DESIGN FLOW Cum/hr 7.5

A AERATION TANK
1 BOD LOAD 18.00
3 VOLUME 45.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 32.40
7 HP OF AERATOR 0.90
8 CHECK FOR AERATOR POWER FOR MIXING 0.67
MINIMUM POWER REQUIRED - KW 0.68
MAXIMUM POWER REQUIRED - KW 1.17
9 AIR REQUIRED 2430
10 LIQUID DEPTH OF AERATION TANK 3.00
11 AREA OF AERATION TANK 15.00
12 WIDTH OF AERATION TANK 2.45 2.45
13 LENGTH OF AERATION TANK 6.12 6.12
14 AREA OF AERATION TANK PROVIDED 15.00 15.00
15 CFM REQUIRED FOR BLOWER 20 HRS 72.32
16 HRS 90.40
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3000

B SETTLING TANK
1 AREA OF SETTLING TANK 12.00
2 WIDTH OF SETTLING TANK REQUIRED 2.45 2.45
3 LENGTH OF SETTLING TANK REQUIRED 4.90 4.90
4 AREA OF SETTLING TANK PROVIDED 12.00 12.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.07
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.70
8 SOLIDS LOAD 720
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 720
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 112.5

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 1.80
2 LIQUID VOLUME 1.80
3 VOLUME OF SDB 1.80
4 AREA OF SDB 6.00
5 NOS. OF SDB 2
6 AREA OF EACH SDB 3.00
7 WIDTH OF SDB 1.22 1.22
8 LENGTH OF SDB 2.45 2.45
9 AREA PROVIDED PER BED 3.0 3.0
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 60 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 75


2 PEAK FLOW Cum/Day 150
3 DESIGN FLOW Cum/hr 6.25

A AERATION TANK
1 BOD LOAD 29.25
3 VOLUME 73.13
4 CHECK FOR HRT 23.40
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 52.65
7 HP OF AERATOR 1.46
8 CHECK FOR AERATOR POWER FOR MIXING 1.09
MINIMUM POWER REQUIRED - KW 1.10
MAXIMUM POWER REQUIRED - KW 1.90
9 AIR REQUIRED 3948.75
10 LIQUID DEPTH OF AERATION TANK 3.00
11 AREA OF AERATION TANK 24.38
12 WIDTH OF AERATION TANK 5.90 5.90
13 LENGTH OF AERATION TANK 4.13 4.13
14 AREA OF AERATION TANK PROVIDED 24.38 24.38
15 CFM REQUIRED FOR BLOWER 20 HRS 117.52
16 HRS 146.90
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3000

B SETTLING TANK
1 AREA OF SETTLING TANK 10.00
2 WIDTH OF SETTLING TANK REQUIRED 2.24 2.24
3 LENGTH OF SETTLING TANK REQUIRED 4.47 4.47
4 AREA OF SETTLING TANK PROVIDED 10.00 10.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.20
7 DEPTH OF HOPPER PORTION 0.97
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 2.70
8 SOLIDS LOAD 600
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 600
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 93.75

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 2.93
2 LIQUID VOLUME 2.93
3 VOLUME OF SDB 2.93
4 AREA OF SDB 9.75
5 NOS. OF SDB 2
6 AREA OF EACH SDB 4.88
7 WIDTH OF SDB 1.56 1.56
8 LENGTH OF SDB 3.12 3.12
9 AREA PROVIDED PER BED 4.9 4.9
DESIGN
PURPOSE
0.10
4000
390
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 400


2 PEAK FLOW Cum/Day 1200
3 DESIGN FLOW Cum/hr 50

A AERATION TANK
1 BOD LOAD 120.00
3 VOLUME 300.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 216.00
7 HP OF AERATOR 6.00
8 CHECK FOR AERATOR POWER FOR MIXING 4.48
MINIMUM POWER REQUIRED - KW 4.50
MAXIMUM POWER REQUIRED - KW 7.80
9 AIR REQUIRED 16200
10 LIQUID DEPTH OF AERATION TANK 3.80 3.80
11 AREA OF AERATION TANK 78.95
12 WIDTH OF AERATION TANK 4.00 4.00
13 LENGTH OF AERATION TANK 19.74 19.74
14 AREA OF AERATION TANK PROVIDED 78.95 78.95
15 CFM REQUIRED FOR BLOWER 20 HRS 482.14
16 HRS 602.68
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3800

B SETTLING TANK
1 AREA OF SETTLING TANK 80.00
2 WIDTH OF SETTLING TANK REQUIRED 4.00 4.00
3 LENGTH OF SETTLING TANK REQUIRED 20.00 20.00
4 AREA OF SETTLING TANK PROVIDED 80.00 80.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.85
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 3.50 3.50
8 SOLIDS LOAD 4800
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 4800
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 750

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 12.00
2 LIQUID VOLUME 12.00
3 VOLUME OF SDB 12.00
4 AREA OF SDB 40.00
5 NOS. OF SDB 6
6 AREA OF EACH SDB 6.67
7 WIDTH OF SDB 1.83 1.83
8 LENGTH OF SDB 3.65 3.65
9 AREA PROVIDED PER BED 6.7 6.7
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 100 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 100


2 PEAK FLOW Cum/Day 300
3 DESIGN FLOW Cum/hr 12.5

A AERATION TANK
1 BOD LOAD 30.00
3 VOLUME 75.00
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 54.00
7 HP OF AERATOR 1.50
8 CHECK FOR AERATOR POWER FOR MIXING 1.12
MINIMUM POWER REQUIRED - KW 1.13
MAXIMUM POWER REQUIRED - KW 1.95
9 AIR REQUIRED 4050
10 LIQUID DEPTH OF AERATION TANK 3.40
11 AREA OF AERATION TANK 22.06
12 WIDTH OF AERATION TANK 3.16 3.16
13 LENGTH OF AERATION TANK 6.98 6.98
14 AREA OF AERATION TANK PROVIDED 22.06 22.06
15 CFM REQUIRED FOR BLOWER 20 HRS 120.54
16 HRS 150.67
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3400

B SETTLING TANK
1 AREA OF SETTLING TANK 20.00
2 WIDTH OF SETTLING TANK REQUIRED 3.16 3.16
3 LENGTH OF SETTLING TANK REQUIRED 6.32 6.32
4 AREA OF SETTLING TANK PROVIDED 20.00 20.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.43
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 3.10
8 SOLIDS LOAD 1200
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 1200
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 187.5

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 3.00
2 LIQUID VOLUME 3.00
3 VOLUME OF SDB 3.00
4 AREA OF SDB 10.00
5 NOS. OF SDB 2
6 AREA OF EACH SDB 5.00
7 WIDTH OF SDB 1.58 1.58
8 LENGTH OF SDB 3.16 3.16
9 AREA PROVIDED PER BED 5.0 5.0
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 225


2 PEAK FLOW Cum/Day 675
3 DESIGN FLOW Cum/hr 28.125

A AERATION TANK
1 BOD LOAD 67.50
3 VOLUME 168.75
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 121.50
7 HP OF AERATOR 3.38
8 CHECK FOR AERATOR POWER FOR MIXING 2.52
MINIMUM POWER REQUIRED - KW 2.53
MAXIMUM POWER REQUIRED - KW 4.39
9 AIR REQUIRED 9112.5
10 LIQUID DEPTH OF AERATION TANK 3.30 3.30
11 AREA OF AERATION TANK 51.14
12 WIDTH OF AERATION TANK 3.00 3.00
13 LENGTH OF AERATION TANK 17.05 17.05
14 AREA OF AERATION TANK PROVIDED 51.14 51.14
15 CFM REQUIRED FOR BLOWER 20 HRS 271.21
16 HRS 339.01
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3300

B SETTLING TANK
1 AREA OF SETTLING TANK 45.00
2 WIDTH OF SETTLING TANK REQUIRED 3.00 3.00
3 LENGTH OF SETTLING TANK REQUIRED 15.00 15.00
4 AREA OF SETTLING TANK PROVIDED 45.00 45.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.35
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 3.00 3.00
8 SOLIDS LOAD 2700
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 2700
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 421.875

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 6.75
2 LIQUID VOLUME 6.75
3 VOLUME OF SDB 6.75
4 AREA OF SDB 22.50
5 NOS. OF SDB 4
6 AREA OF EACH SDB 5.63
7 WIDTH OF SDB 1.68 1.68
8 LENGTH OF SDB 3.35 3.35
9 AREA PROVIDED PER BED 5.6 5.6
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 337.5


2 PEAK FLOW Cum/Day 1012.5
3 DESIGN FLOW Cum/hr 42.1875

A AERATION TANK
1 BOD LOAD 101.25
3 VOLUME 253.13
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 182.25
7 HP OF AERATOR 5.06
8 CHECK FOR AERATOR POWER FOR MIXING 3.78
MINIMUM POWER REQUIRED - KW 3.80
MAXIMUM POWER REQUIRED - KW 6.58
9 AIR REQUIRED 13668.75
10 LIQUID DEPTH OF AERATION TANK 4.30 4.30
11 AREA OF AERATION TANK 58.87
12 WIDTH OF AERATION TANK 5.00 5.00
13 LENGTH OF AERATION TANK 11.77 11.77
14 AREA OF AERATION TANK PROVIDED 58.87 58.87
15 CFM REQUIRED FOR BLOWER 20 HRS 406.81
16 HRS 508.51
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 4300

B SETTLING TANK
1 AREA OF SETTLING TANK 67.50
2 WIDTH OF SETTLING TANK REQUIRED 5.00 5.00
3 LENGTH OF SETTLING TANK REQUIRED 25.00 25.00
4 AREA OF SETTLING TANK PROVIDED 125.00 125.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 2.35
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 4.00 4.00
8 SOLIDS LOAD 4050
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 4050
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 632.8125

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 10.13
2 LIQUID VOLUME 10.13
3 VOLUME OF SDB 10.13
4 AREA OF SDB 33.75
5 NOS. OF SDB 10
6 AREA OF EACH SDB 3.38
7 WIDTH OF SDB 1.30 1.30
8 LENGTH OF SDB 2.60 2.60
9 AREA PROVIDED PER BED 3.4 3.4
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30
SR. PARTICULARS CRITERIA UNIT
NO.
1 F/M RATIO 0.15 - 0.05
2 MLSS 3000 - 8000 mg/lit
3 BOD 250 - 300 mg/lit
4 HRT 18 - 36 hrs
5 OXYGEN REQUIREMENT 1.80 - 1.20
6 OXYGEN TRANSFER CAPACITY 1.50 Kg/HPHr
7 CHECK FOR AERATOR HP FOR MIXING 0.015 - 0.026 Kw/Cum
8 AIR REQUIRED 100 - 135 Kg/Cum
9 HOURS OF AERATION 16 - 20 Hrs
10 SOLIDS LOADING RATE [SLR] 8 - 15 hrs
11 SOLIDS LOADING 100 - 150 Kg/Day/Sqm
11 WEIR LOADING 100 - 150 Cum/Day/M
12 MINIMUM LIQUID DEPTH FOR SETTLING 1.50 M
13 EXCESS SLUDGE 0.10 Kg
14 SLUDGE DRYING PERIOD 10 Days
15 L/B RATIO FOR SDB 1: 2
16 MINIMUM DEPTH OF SLUDGE 0.30 M

RADIANT PACKAGE TREATMENT PLANT - 20 CUM/DAY

SR. PARTICULARS
NO.

1 AVERAGE FLOW Cum/Day 450


2 PEAK FLOW Cum/Day 1350
3 DESIGN FLOW Cum/hr 56.25

A AERATION TANK
1 BOD LOAD 135.00
3 VOLUME 337.50
4 CHECK FOR HRT 18.00
5 CHECK FOR VOLUMETRIC LOADING 0.40
6 OXYGEN REQUIRED 243.00
7 HP OF AERATOR 6.75
8 CHECK FOR AERATOR POWER FOR MIXING 5.04
MINIMUM POWER REQUIRED - KW 5.06
MAXIMUM POWER REQUIRED - KW 8.78
9 AIR REQUIRED 18225
10 LIQUID DEPTH OF AERATION TANK 3.90 3.90
11 AREA OF AERATION TANK 86.54
12 WIDTH OF AERATION TANK 4.24 4.24
13 LENGTH OF AERATION TANK 20.40 20.40
14 AREA OF AERATION TANK PROVIDED 86.54 86.54
15 CFM REQUIRED FOR BLOWER 20 HRS 542.41
16 HRS 678.01
AS PER PARRYS TABLE
PRESSURE IN mm WATER GUAGE 3900

B SETTLING TANK
1 AREA OF SETTLING TANK 90.00
2 WIDTH OF SETTLING TANK REQUIRED 4.24 4.24
3 LENGTH OF SETTLING TANK REQUIRED 21.21 21.21
4 AREA OF SETTLING TANK PROVIDED 90.00 90.00
5 SIZE OF SLUDGE PIT 0.30
6 DEPTH OF SLUDGE PIT 0.15
7 DEPTH OF HOPPER PORTION 1.97
8 LIQUID DEPTH ABOVE HOPPER PORTION 1.50
9 TOTAL LIQUID DEPTH OF SETTLING TANK 3.60 3.60
8 SOLIDS LOAD 5400
9 CHECK FOR SOLIDS LOADING RATE 60
10 WEIR LOAD 5400
11 PERIMETER OF LAUNDER 6.40
12 CHECK FOR WEIR LOADING RATE 843.75

C SLUDGE DRYING BEDS


1 EXCESS SLUDGE 13.50
2 LIQUID VOLUME 13.50
3 VOLUME OF SDB 13.50
4 AREA OF SDB 45.00
5 NOS. OF SDB 6
6 AREA OF EACH SDB 7.50
7 WIDTH OF SDB 1.94 1.94
8 LENGTH OF SDB 3.87 3.87
9 AREA PROVIDED PER BED 7.5 7.5
DESIGN
PURPOSE
0.10
4000
300
18
1.80
1.50
0.015 - 0.026
135
16 - 20
15
100
100
1.50
0.10
10
1: 2
0.30