Professional Documents
Culture Documents
page 59
D6..AB Series for Sea Water Media Applications
–– D6..AB Series Butterfly Valves
–– Dimensions and Sizing Chart
page 62
D6..D(S) Series for Large Size Pipe Applications
–– D6..D(S) Series Butterfly Valves
–– Dimensions and Sizing Chart
page 65
D6..H Series for High Close-off Pressure Applications
–– D6..H Series Butterfly Valves
–– Dimensions and Sizing Chart
page 68
Complementary Products
–– QB..
–– XZA..
page 70
page 73
page 77
Appendix
–– Manual Operator
–– ZD6..
page 83
Contents
3
BFV and Actuators Product Range Overview and Applications
Complementary 2-way Motorised Butterfly Valve* • Media: Sea water, brine • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SR..A..-5, GR..A..-5/-7, DR..A..-7,
• Special for sea water or brine media DN50...800,1600kPa and SY and QB* series
• Material: • Max. Close-off pressure:
Ductile cast iron body 1200kPa (DN50...600)
NBR seat 1000kPa (DN700...800)
Aluminium bronze disc • Temperature: -10...+80°C
Stainless steel shaft • Pipe connection:
PN10/16 and Table E for wafer
(DN50...300)
PN16 for wafer (DN350...800)
Complementary 2-way Motorised Butterfly Valve* • Media: Cold and hot water, glycol • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SY and QB* series
• Special for large size pipe DN600...1200,1600kPa
• Material: • Max. Close-off pressure:
Ductile cast iron body 1200kPa (DN600)
EPDM seat 1000kPa (DN700...1200)
Nylon coated/Stainless steel disc • Temperature: -20...+100°C
Stainless steel shaft • Pipe connection: PN16 for wafer
Complementary 2-way Motorised Butterfly Valve* • Media: Cold and hot water, glycol • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SY and QB* series
• Special for high Close-off pressure DN50...500,2500kPa
• Material: • Max. Close-off pressure: 2200kPa
Ductile cast iron body • Temperature: 0...+95°C
EPDM seat -20...+100°C
Stainless steel disc • Pipe connection:
Carbon steel shaft ISO 7005.2 PN25 for lug
(DN50...500)
Manual Butterfly Valve* • Media: Cold and hot water, glycol • Handle and worm gear:
• Shut off or control function • Nominal size and pressure: ZD6.. series
• General HVAC application DN50...500,1600kPa
• Material: • Max. Close-off pressure: 1200kPa
Ductile cast iron body • Temperature: 0...+95°C
EPDM seat -20...+100°C
Nylon coated/Stainless steel disc • Pipe connection:
Stainless steel shaft PN10/16 and Table E for wafer
(DN50...300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
*Trade selection by Belimo
2500
Range A Nylon coated disc plus EPDM seat
2200 BU6.., D6..D, D6..MH/MW
2000
Max. Close-off Pressure (kPa)
1800
1600
1400
Application Range
1200
1000
800
600
V7.3 08.2015• Subject to modification
400
200
0
4 UL marked actuators is optional, please contact your local Sales Representative for details.
BFV and Actuators Product Range Overview and Applications
EPDM NBR
2500 Stainless Steel Disc 2500
2200 2200
2000 2000
1800 1800
Pressure (kPa)
Pressure (kPa)
1600 1600
1400 N
Nylon Coated
a Discc 1400
1200 1200
1000 1000
800 800
200 200
0 0
Seat + Disc Water Sea water Glycol 2200 1200 600 400 -20 -10 0 80 100
Standard Motorised NC BU6.. Series*
Large Size Motorised NC D6..D Series EPDM + NC X
Manual NC D6..MH/MW
Standard Motorised SS BU6.. S*
Large Size Motorised SS D6..DS
EPDM + SS304 X
PN25 Motorised SS D6..H
Manual SS D6..SMH/SMW
Sea Water D6..AB NBR + AB
*BU6200X/LX, BU6200SX/LSX is utilised at 600kPa only.
Reference Standard:
UL marked actuators is optional, please contact your local Sales Representative for details. 5
BU6.. Series Product Overview
DN[mm] 50 65 80 100 125 150 200 250 300 350 400 450 500
Wafer
BU6.. BU650 BU665 BU680 BU6100 BU6125 BU6150 BU6200.. BU6250 BU6300 BU6350 BU6400 BU6450 BU6500
Type
Lug
BU6..L BU650L BU665L BU680L BU6100L BU6125L BU6150L BU6200L.. BU6250L BU6300L BU6350L BU6400L BU6450L BU6500L
kv
SR24A(-S)-5 GR..A..-5 GR..A..-7 DR..A..-7
SR230A(-S)-5 GRK..A..-5 GRK..A..-7
IP54 SRFA-5
Y SRFA-S2-5
With Open/
SY1-24-3-T SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8..
Close
IP67 SY1-230-3-T
actuator
kv SR24A-SR-5 GR..A..-5 GR..A..-7 DR..A..-7
IP54 SRF24A-SR-5 GRK..A..-5 GRK..A..-7
With SY1U24-SR-T
IP67 SY1U230-SR-T
SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8..
Modulating
actuator
Note: Stainless Steel disc (BU6..S series) is available on request.
6
BU6.. Series Product Overview
Belimo BU6..series Butterfly Valves are designed to meet the stringent needs Belimo General Rotary Actuators, Fail-Safe Rotary Actuators designed for
of HVAC applications requiring positive shut-off for liquids. BU6.. Series BFV.
Valve design features Belimo SRF..A..-5, GRK..A..-5/-7, SR..A..-5, GR..A..-5/-7, DR..A..-7 series
2 Rotary Actuators use the best possible electric motors and gearings and
1 also employ highly sophisticated electronics for the control. The universal
product design makes installation, operation and service much easier.
3
5 4
GR..A..-5 /-7
7
6
9 10
1. Mounting flange according to ISO 5211. To satisfy higher IP requirement and large size butterfly automation, Belimo
2. Square shaft head for form-fit attachment of the Rotary Actuator. offers SY..series Rotary Actuators which are designed to mate with the
3. Shaft with EPDM O-ring seal. BU6..series Butterfly Valves and other quarter-turn valve applications.
4. RPTFE shaft bearing.
SY.. Actuator design features
5. Full series of valve body made of ductile cast iron (DN50...500).
6. Hole pattern for PN10/16, Table E (wafer, DN50...300)
9
PN16 (wafer DN350...500, Lug DN50...500)
7. Shaft made of stainless steel 416. 7
8. Double-D-fit attachment of the shaft to the disc.
8
9. The disc made of ductile cast iron nylon coated or stainless steel 304.
10. EPDM seat symmetrical, integrated flange sealing.
7
The Sizing of BU6..Series Butterfly Valves
Kv Value [m3/h]
Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
BU650.. DN50 2” 80 75 57 39 27 21 16 6.9 1.09
BU665.. DN65 2.5” 170 142 99 64 42 30 19 7.5 5.2
BU680.. DN80 3” 290 278 205 139 87 51 34 21 7.7
BU6100.. DN100 4” 560 404 270 137 105 67 46 26 6.3
BU6125.. DN125 5” 870 744 502 306 186 113 60 33 15.6
BU6150.. DN150 6” 1340 1185 720 472 294 171 94 47 25.9
BU6200.. DN200 8” 2690 2360 1483 956 617 362 211 88 52.0
BU6250.. DN250 10” 5540 3948 2364 1502 911 588 334 193 84.5
BU6300.. DN300 12” 7540 6147 3607 2083 1229 706 401 164 4.13
BU6350.. DN350 14” 10300 9348 6233 3938 2380 1335 606 291 5.2
BU6400.. DN400 16” 14300 12856 8571 5416 3237 1836 847 400 6.9
BU6450.. DN450 18” 18900 17028 11352 7172 4334 2433 1122 530 9.5
BU6500.. DN500 20” 24200 21893 14596 9222 5573 3128 1443 682 12
Note: the maximum velocity in the butterfly valve is 6m/s (for Open/Close control).
Type
Type
8
The Sizing of BU6..Series Butterfly Valves
9
BU6.. Series Butterfly Valves, Wafer or Lug Pattern
DN50...500
Technical data
Flow medium Nylon coated disc: Cold and hot water
SS304 disc: cold and hot water. Max. 50% Glycol
Temperature of medium Nylon-coated disc: 0...+95°C
SS304 disc: -20...+100°C
Nominal pressure 1600kPa (PN16)
Flow characteristic Modified equal-percentage
Rangeability 10:1 (for 30°... 70° range)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
Max. Close-off pressure 1200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50...500)
Disc Nylon coated ductile cast iron disc / Stainless steel 304 disc
Seat EPDM
Shaft Stainless steel 416
Bushing RPTFE
Ordering sample
BU6 125 L / GR230A-7
Actuator: GR230A-7 actuators, Open/Close,
AC 100...240V
Default: Only SY Actuators and its Butterfly Valves are pre-
calibrated and pre-assembled in the factory
Package: “/” Valve and actuator supplied separately on request
Disc and flange* L(X)-Lug, Nylon coated disc
pattern: default(X)-Wafer, Nylon coated disc
LS(X)-Lug, stainless steel disc
S(X)-Wafer, stainless steel disc
Size: DN125
Butterfly Valve: BU6.. Low torque series
* BU6200X/LX, BU6200SX/LSX is utilised at 600kPa only.
Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.
Mode of operation
The BU6.. series Butterfly Valves are operated by General Rotary Actuators, Mechanical
Fail-Safe Rotary Actuators or SY Large Torque Multi-function Actuators are available. Select
the actuators according to required Close-off pressure and HVAC condition of installation.
The actuators are controlled by a standard Open/Close or modulating control system and
rotate the disc of the valve to the position dictated by the control signal.
V7.3 08.2015• Subject to modification
Manual operation
The manual operation is available by using a lever with manual override button of SR..,
GR.., DR.. actuator pressed or turning a handwheel of actuators.
10 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of BU6.. Series Butterfly Valves
Wafer connection Lug connection
BU6500L.. DN500 F14 127 472 703 375 466 38 22 36 210 650 20-M30 153.3 154.1
UL marked actuators is optional, please contact your local Sales Representative for details. 11
SR24A-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC/DC 24V
• Control Open/Close, 3-point
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.2W
Power consumption for wire sizing 5.5VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
Product features
V7.3 08.2015• Subject to modification
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
12 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC/DC 24V, 20Nm SR24A-5
Product features
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Electrical installation
Wiring diagrams
1 2 3 1 2 3
Y1 Y1
Y2 Y2 Y2 Y2 Y1
Cable colours: Cable colours:
1 = black 1 = black
Y2 2 = red Y2 2 = red
A – AB = 0% 3 = white A – AB = 0% 3 = white
Dimensions [mm]
Dimensional drawings 33 118
84
93
V7.3 08.2015• Subject to modification
70
176 108 43
UL marked actuators is optional, please contact your local Sales Representative for details. 13
SR24A-SR-5
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.4W
Power consumption for wire sizing 5VA
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Positioning signal Y DC (0)2...10V
Positioning signal Y note Input impedance 100kΩ
Operating range Y DC 2...10V
Position feedback U DC 2...10V
Position feedback U note Max. 1mA
Position accuracy ±5%
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
V7.3 08.2015• Subject to modification
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
Product features
Mode of operation The actuator is connected with a standard modulating signal of DC (0)2...10V and travels to
the position defined by the positioning signal. Measuring voltage U serves for the electrical
display of the valve position 0...100% and as slave control signal for other actuators.
14 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Modulating, AC/DC 24V, 20Nm SR24A-SR-5
Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-onT ~ P2800A
Feedback potentiometer 5 kOhm, – add-on
+ P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Y DC (0)2...10V
U DC 2...10V
Electrical installation
1 2 3 5
Notes • Connection via safety isolating transformer.
! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch
Y1
is covered. Factory setting: Direction of rotation Y2.
Y2
Wiring diagrams
AC/DC 24V, modulating Override control (frost protection circuit)
T ~ T ~
– + – +
Y DC (0)2...10V
Y DC (0)2...10V c d
U DC 2...10V
Y1 A – AB = 100%
Y2 A – AB = 0%
T ~ DC (0)2...10 V
– +
Y DC (0)2...10V
Dimensions c[mm]
d
Y1
Y2
84
c d Y1 / Y2
Y1 A – AB = 100%
Y2 A – AB = 0%
DC (0)2...10 V
V7.3 08.2015• Subject to modification
93
70
176 108 43
UL marked actuators is optional, please contact your local Sales Representative for details. 15
SR230A-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC 230V
• Control Open/Close, 3-point
Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 3W
Power consumption in rest position 0.6W
Power consumption for wire sizing 7VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN II Protective insulated
Protection class UL II Protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 4kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage!
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
V7.3 08.2015• Subject to modification
Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
16 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC 230V, 20Nm SR230A-5
Product features
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Electrical installation
Wiring diagrams
1 2 3 1 2 3
Y1 Y1
Y2 Y2 Y2 Y2 Y1
Cable colours: Cable colours:
1 = blue 1 = blue
Y2 2 = brown Y2 2 = brown
A – AB = 0% 3 = white A – AB = 0% 3 = white
Dimensions [mm]
Dimensional drawings 33 118
84
93
V7.3 08.2015• Subject to modification
70
176 108 43
UL marked actuators is optional, please contact your local Sales Representative for details. 17
SR24A-S-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC/DC 24V
• Control Open/Close, 3-point
• With integrated auxiliary switch
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.2W
Power consumption for wire sizing 5.5VA
Auxiliary switch 1 x SPDT, 0...100%
Switching capacity auxiliary switch 1mA...3 (0.5) A, AC 250 V (II Protective
insulated)
Connection supply / control Cable 1m, 3 x 0.75mm²
Connection auxiliary switch Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Rated impulse voltage auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Mechanical data F05
Weight Weight Approx. 1kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
V7.3 08.2015• Subject to modification
of as household refuse. All locally valid regulations and requirements must be observed.
Product features
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting
position in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
18 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Cose, 3-point, AC/DC 24V, 20Nm SR24A-S-5
Product features
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
Flexible signalisation With adjustable auxiliary switch (0...100%)
Auxiliary switch
1 1
S1 S2 S3 S1 S2 S3
0 0
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Electrical installation
Wiring diagrams
AC/DC 24V, Open/Close AC/DC 24V, 3-point
T ~ T ~
– + – +
1 2 3 S1 S2 S3 1 2 3 S1 S2 S3
Cable colours: Cable colours:
Y1 1 = black 1 = black
Y1
Y2 0 ... 100%
2 = red Y2 Y1 2 = red
Y2 0 ... 100%
3 = white Y2 3 = white
Y2 S1 = violet S1 = violet
A – AB = 0% S2 = red Y2 S2 = red
S3 = white A – AB = 0% S3 = white
Dimensions [mm]
33 117
Dimensional drawings
84
21
V7.3 08.2015• Subject to modification
93
70
176 150
UL marked actuators is optional, please contact your local Sales Representative for details. 19
SR230A-S-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC 230V
• Control Open/Close, 3-point
• With integrated auxiliary switch
Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 3W
Power consumption in rest position 0.6W
Power consumption for wire sizing 7VA
Auxiliary switch 1 x SPDT, 0...100%
Switching capacity auxiliary switch 1mA...3 (0.5) A, AC 250V (II Protective
insulated)
Connection supply / control Cable 1m, 3 x 0.75mm²
Connection auxiliary switch Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, pluggable
Safety Protection class IEC/EN II Protective insulated
Protection class UL II Protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 4kV
Rated impulse voltage auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage!
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
V7.3 08.2015• Subject to modification
20 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC 230V, 20Nm SR230A-S-5
Product features
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting
position in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
Flexible signalisation With adjustable auxiliary switch (0...100%)
Auxiliary switch
1 1
S1 S2 S3 S1 S2 S3
0 0
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Electrical installation
Notes • Caution: Power supply voltage!
• Parallel connection of other actuators possible. Observe the performance data.
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.
Wiring diagrams
AC 230V, Open/Close AC 230V, 3-point
N L T ~
– +
1 2 3 S1 S2 S3
Cable colours: 1 2 3 S1 S2 S3 Cable colours:
1 = blue 1 = blue
Y1 2 = brown 2 = brown
Y2
Y2
0...100% 3 = white Y1
3 = white
Y2 Y1 0 ... 100%
S1 = violet Y2 S1 = violet
Y2 S2 = red S2 = red
A – AB = 0% S3 = white Y2 S3 = white
A – AB = 0%
Dimensions [mm]
33 117
Dimensional drawings
84
21
V7.3 08.2015• Subject to modification
93
70
176 150
UL marked actuators is optional, please contact your local Sales Representative for details. 21
GR24A-5 / -7
GR24A-5 Rotary actuator for rotary valves
GR24A-7 Rotary actuator for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC/DC 24V
• Control Open/Close
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 4W
Power consumption at rest 2W
Power consumption for wire sizing 6VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor GR24A-5 min. 40Nm
GR24A-7 min. 40Nm
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Rated current voltage motor 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GR24A-5 F05
GR24A-7 F07
Weight Weight Approx. 1.85kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
Product features
V7.3 08.2015• Subject to modification
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
22 UL marked actuators is optional, please contact your local Sales Representative for details.
GR24A-5 / -7
Product features
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Wiring diagram
GR24A-5/-7
AC/DC 24V, Open/Close
T ~ T ~
– + – +
1 2 3 1 2 3
Y1 Y1
Y2 Y2 Y1
Y2 Y2
Cable colours:
1 = black
Y2 2 = red Y2
A – AB = 0% 3 = white A – AB = 0%
Dimensions [mm]
GR24A-5/-7 210
97
6/ 8
124
V7.3 08.2015• Subject to modification
47.5°
69 174
UL marked actuators is optional, please contact your local Sales Representative for details. 23
GR24A-SR-5 / -7
Modulating rotary actuator for rotary valves
GR24A-SR-5 with mounting flange ISO 5211-F05
GR24A-SR-7 with mounting flange ISO 5211-F07
• Torque 40Nm
• Nominal voltage AC/DC 24V
• Control: modulating DC(0) 2...10V
• Position feedback DC 2...10V
Technical data
Electrical data Nominal voltage AC 24V, 50/60 Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power In operation 4.5W @ nominal torque
consumption At rest 1.5W
For wire sizing 6.5VA
Connection Cable 1m, 4 x 0.75mm²
Parallel operation Possible, note the performance data
Functional data Torque (nominal torque) Min. 40Nm @ nominal voltage
Control Control signal Y DC (0)2...10V, typical input impedance 100kΩ
Operating range Y DC 2...10V
Position feedback DC 2...10V, max. 1mA
Position accuracy ±5%
Manual override Gearing latch disengaged with pushbutton,
can be locked
Running time 150s / 90°
Sound power level Max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection EMA/UL NEMA 2, UL Enclosure Type 2
EMC CE in accordance with 2004/108/EU
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature 0...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange GR24A-SR-5 F05
GR24A-SR-7 F07
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.5kg
Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during assembly.
• The switch for changing the direction of rotation may only be operated by authorised per-
sonnel. The direction of rotation must not be reversed in a frost protection circuit.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
V7.3 08.2015• Subject to modification
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
24 UL marked actuators is optional, please contact your local Sales Representative for details.
GR24A-SR-5 / -7
Product features
Mode of operation The actuator is controlled with a standard modulating signal of DC (0)2...10V and travels to
the position defined by the control signal. Measuring voltage U serves for the electrical dis-
play of the actuator position 0...100% and as slave control signal for other actuators.
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Wiring diagram
GR24A-SR-5 Standard connection Override control (Frost protection circuit)
T ~ T ~
Notes – + – +
• Connect via safety isolation transformer. ! Y DC
DC (0)2...10V
0 ... 10 V Y DC
DC (0)2...10V
0 ... 10 V
• Other actuators can be connected in parallel. No- Control of controller c d Control of controller
te performance data for supply.
U DC 2 ... 10 V
• Direction of rotation switch is covered. Measuring voltage
Factory setting: Direction of rotation Y2 for reset signal
1 2 3 5 1 2 3 5 Cable
colours:
1 = black
2 = red
Direction of rotation Y1 3 = white
Y2
5 = orange
c d Actuator Butterfly valve
Y1 A – AB = 100%
Y2 A – AB = 0%
Modulating operation
Cable
V7.3 08.2015• Subject to modification
1 2 3 5 1 2 3 5
colours:
1 = black
Direction of rotation Y1 2 = red
3 = white
Y2 5 = orange
c d Actuator Butterfly valve
Y1 A – AB = 100%
Y2 A – AB = 0%
Modulating operation
UL marked actuators is optional, please contact your local Sales Representative for details. 25
GR24A-SR-5 / -7
Dimensions [mm]
GR24A-SR-5 44 151
98
133
0
R1
59 141 43
GR24A-SR-7 44 151
98
133
0
R1
59 141 43
V7.3 08.2015• Subject to modification
26 UL marked actuators is optional, please contact your local Sales Representative for details.
GR230A-5 / -7
GR230A-5 Rotary actuator for rotary valves
GR230A-7 Rotary actuator for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC 230V
• Control Open/Close
Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 5W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor GR230A-5 min. 40Nm
GR230A-7 min. 40Nm
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN II protective insulated
Protection class UL II protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
Electromagnetic compatibility CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Rated current voltage motor 4kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GR230A-5 F05
GR230A-7 F07
Weight Weight Approx. 1.85kg
Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
V7.3 08.2015• Subject to modification
of as household refuse. All locally valid regulations and requirements must be observed.
Product features
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
UL marked actuators is optional, please contact your local Sales Representative for details. 27
GR230A-5 / -7
Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Wiring diagram
GR230A-5/-7
AC 230V, Open/Close
N L N L
1 2 3 1 2 3
Y1 Y1
Y2 Y2 Y1
Y2 Y2
Cable colours:
1 = blue
Y2 2 = brown Y2
A – AB = 0% 3 = white A – AB = 0%
Dimensions [mm]
44 151
GR230A-5/-7
98
59 141 43
28 UL marked actuators is optional, please contact your local Sales Representative for details.
DR..A(-SR)-7 Rotary Actuator
DR24A(-SR)-7 Rotary actuator for butterfly valves
• Nominal torque 90Nm
• Nominal voltage AC/DC 24V
• Open/Close Control: DR24A-7
• Modulating Control: DR24A-SR-7
Technical data
Basc technical data Nominal voltage frequency 50/60Hz
Parallel operation No
Torque motor Max. 90Nm (not constant)
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Yes
Degree of protection IEC/EN IP54
EMC CE according to 2004/108/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Connection flange F07
Weight Approx. 3.6kg
DR24A-7 Nominal voltage AC/DC 24V
Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V
Power consumption in operation 4.5W
Power consumption at rest 2W
Power consumption for wire sizing 7VA
Connection Cable 1m, 3 x 0.75mm²
Protection class IEC/EN III Safety extra-low voltage
Rated current voltage 0.8kV
DR24A-SR-7 Nominal voltage AC/DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 7W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection Cable 1m, 4 x 0.75mm²
Protection class IEC/EN III Safety extra-low voltage
Rated current voltage 0.8kV
DR230A-7 Nominal voltage AC 100...240V
Nominal voltage range AC 85...265V
Power consumption in operation 5W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection Cable 1m, 3 x 0.75mm²
Protection class IEC/EN II totally insulated
Rated current voltage 4kV
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 29
DR..A(-SR)-7 Rotary Actuator
Safety notes
• This actuator has been designed for use in stationary heating, ventilation and air-conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may not be adjusted.
• The angle of rotation is not permitted to be subjected to mechanical limitation. It is forbidden
to alter the mechanical end stops.
• The device may only be opened at the manufacturer’s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• For DR24A-7, the device contains electrical and electronic components and is not allowed
to be disposed of as household refuse. All locally valid regulations and requirements must
be observed.
• For DR230A-7, caution: power supply voltage!
Product features
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Direct mounting Simple direct mounting on the butterfly valves with ISO 5211-F07 mounting flange. The
mounting orientation with reference to the butterfly valve can be selected in 90° (angle) steps.
Manual override For DR24A-7, Manual operation is possible with the push-button (the gearing latch remains
disengaged as long as the push-button is pressed or detented).
For DR24A-SR-7, manual override with push-button possible (the gear is disengaged for as
long as the button is pressed or remains locked).
For DR230A-7, manual override with push-button possible (the gear is disengaged for as
long as the button is pressed or remains locked).
Mode of operation For DR24A-SR-7, the actuator is connected with a standard modulating signal of DC 0 ...
10V and travels to the position defined by the positioning signal. The measuring voltage U
serves for the electrical display of the actuator position 0 ... 100% and as slave control signal
for other actuators.
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Wiring diagram
DR24A-7
AC/DC 24V, Open/Close
T ~
– +
1 2 3
V7.3 08.2015• Subject to modification
Y1
Y2
Y2
Cable colours:
1 = black
Y2 2 = red
A – AB = 0% 3 = white
30 UL marked actuators is optional, please contact your local Sales Representative for details.
DR..A(-SR)-7 Rotary Actuator
T ~
Wiring diagram – +
Y DC 0 ... 10 V
Notes • Connection via safety isolating transformer. c d
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.
DR24A-SR-7 1 2 3 5
AC/DC 24V, modulating AC/DC 24V, modulating, override control
T ~ T ~
– + – + Y1
Y DC 0 ... 10 V
Y DC 0…10 V c d Y2
U DC 2…10 V c d Y1 / Y2
Y1 A – AB = 100%
1 2 3 5 1 2 3 5 Y2 A – AB = 0%
Cable colours: DC 0...10 V
1 = black
Y1 2 = red
Y1
3 = white
Y2 5 = orange Y2
c d Y1 / Y2
Y1 A – AB = 100%
DR230A-7 Y2 A – AB = 0%
DC 0...10 V
AC 230V, Open/Close
N L
1 2 3
Y1
Y2
Y2
Cable colours:
1 = blue
Y2 2 = brown
A – AB = 0% 3 = white
Dimensions [mm]
72 146 41
DR24A-7
DR24A-SR-7
DR230A-7
129
20
152 72
172
V7.3 08.2015• Subject to modification
224
UL marked actuators is optional, please contact your local Sales Representative for details. 31
DR24A-MP-7 Rotary Actuator
Communicative rotary actuator for butterfly valves
• Nominal torque 90Nm
• Nominal voltage AC/DC 24V
• Control Modulating: DC (0)2...10V variable
• Position feedback: DC 2...10V variable
• Communication via Belimo MP-Bus
• Conversion of sensor signals
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 9W
Power consumption at rest 2W
Power consumption for wire sizing 12VA
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation No
Functional data Torque motor max. 90Nm (not constant)
Positioning signal Y DC 0...10V
Positioning signal Y note Input impedance 100kΩ
Control signal Y variable Open/Close
3-point (AC only)
Modulating (DC 0...32V)
Operating range Y DC 2...10V
Operating range Y variable Start point DC 0.5...30V
End point DC 2.5...32V
Position feedback U DC 2...10V
Position feedback U note Max. 0.5mA
Position feedback U variable Start point DC 0.5...8V
End point DC 2.5...10V
Position accuracy ±5%
Manual override Gear disengagement with push-button, can be
locked
Running time motor 150 s / 90°
Motor running time variable 75...290 s
Automatic adjustment of operating Automatic adaptation of operating range and
range to match the mechanical feedback to match the mechanical angle of
angle of rotation rotation:Manual triggering of the adaption by
pressing the «Adaption» button or with the PC-Tool
Override control MAX (maximum position) = 100%
MIN (minimum position) = 0%
ZS (intermediate position, AC only) = 50%
Override control variable MAX = (MIN + 30°)...100%
MIN = 0%...(MAX – 30°)
ZS = MIN...MAX
Sound power level motor max. 45dB(A)
Position indication Yes
Safety Protection class IEC/EN III Safety extra-low voltage
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
V7.3 08.2015• Subject to modification
32 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator
Safety notes
• This device has been designed for use in stationary heating, ventilation and air
conditioning systems and is not allowed to be used outside the specified field of
! application, especially in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may not be adjusted.
• The angle of rotation is not permitted to be subjected to mechanical limitation. It is
forbidden to alter the mechanical end stops.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be
disposed of as household refuse. All locally valid regulations and requirements must be
observed.
Product features
Mode of operation Conventional operation:
The actuator is connected with a standard modulating signal of DC 0...10V and travels
to the position defined by the positioning signal. The measuring voltage U serves for the
electrical display of the actuator position 0...100% and as slave control signal for other
actuators.
Operation on the MP-Bus:
The actuator receives its digital positioning signal from the higher level controller via
the MP-Bus and travels to the position defined. Connection U serves as communication
interface and does not supply an analogue measuring voltage.
Converter for sensors Connection option for a sensor (passive or active sensor or switching contact). The MP
actuator serves as an analogue/digital converter for the transmission of the sensor signal
via MP-Bus to the higher level system.
Parameterisable actuators The factory settings cover the most common applications. Input and output signals and
other parameters can be altered with the PC-Tool MFT-P or with the Service tool ZTH AP.
Direct mounting Simple direct mounting on the butterfly valve. The mounting orientation in relation to the
butterfly valve can be selected in 90° (angle) increments.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the
button is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops
when the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm
Home position The actuator moves to the home position when the supply voltage is switched on for the
first time, i.e. at the time of commissioning or after pressing the «gear disengagement»
key.
Factory setting: Y2 (counter-clockwise rotation).
The actuator then moves into the position defined by the positioning signal.
Y2 A – AB = 0%
Y1 A – AB = 100%
Accessories
Description Type
Accessories (continued)
Description Type
Service Tools Service Tool, for MF/MP/Modbus/LonWorks actuators and VAV-Controller ZTH AP
Belimo PC-Tool, software for adjustments and diagnostics MFT-P
Adapter to Service-Tool ZTH MFT-C
ZIP-USB-MP interface ZIP-USB-MP
Wiring diagram
Notes • Connection via safety isolating transformer.
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.
Wiring diagrams
Y DC (0)2...10 V Y Sensor
U DC 2...10 V U MP
Functions
A)
T ~ T ~
– + MP – + MP
A) A)
34 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator
Functions
Connection of passive sensors
T ~
– + MP
2)
PT1000 –35...+155°C 850...1600
Y U 1) Depending on the type
NTC –10...+160°C 1) 2)
2) Resolution 1Ohm
Override control with AC 24V with relay contacts Override control with AC 24V with rotary switch
T ~ T ~
Y (DC 0...10 V)
c Y (DC 0...10 V)
2 3 e.g. 1N 4007
a b 1 4
e.g. 1N 4007
ab c Pos
0% 10 %
1 2 35 ZS 50% 1 2 35 2 ZS 50%
100% 3 100%
Y U Y U
Y 4 Y
Remote control 0...100% positioner SG.. Minimum limit with positioner SG..
T ~ T ~
T ~ SGA24 T ~ SGA24
Y Z SGF24 Y Z SGF24
1 2 3 4 SGE24 1 2 3 4 SGE24
Y [V]
10
Y (DC 0...10 V)
min
1 2 35 1 2 35
Y U Y U 0 [%
0 100
U DC 2...10 V
V7.3 08.2015• Subject to modification
1 2 35 1 2 35 1 2 35
Y U Y U Y U
(1) Adapting the direction of rotation
UL marked actuators is optional, please contact your local Sales Representative for details. 35
DR24A-MP-7 Rotary Actuator
Functions
Follow-up control (position-dependent) Position indication
T ~
– +
T ~
500 – +
(–)
4...20 mA
(+)
Procedure
U DC 2...10 V
1. Connect 24V to connections 1 and 2
2. Disconnect connection 3:
Caution: – with direction of rotation 0: Actuator
1 2 35 The operating range must be 1 2 35 rotates to the left
set to DC 2...10V. – with direction of rotation 1: Actuator
The 500Ω resistor converts the rotates to the right
Y U 4...20mA current signal to a Y U 3. Short-circuit connections 2 and 3:
voltage signal DC 2...10V – Actuator runs in opposite direction
Functions for actuators with specific parameters (Parametrisation with PC-Tool necessary)
Override control and limiting with AC 24V Override control and limiting with AC 24V
with relay contacts with rotary switch
T ~ T ~
Close 1)
Y (DC 0...10 V)
Open
Y (DC 0...10 V)
MAX
e
MIN
ZS
ab cd e.g. 1N 4007
e.g. 1N 4007
ab cd e
Close 1)
MIN
12 3 5 ZS 12 3 5
MAX 1) Caution: This function is only
guaranteed if the start point of
Y U Open Y U the operating range is defined as
Y min. 0.6V.
a b
e.g. 1N 4007
U U
ab
1 2 3 5 12 3 5
stop
Y U Y U
V7.3 08.2015• Subject to modification
36 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator
5 Service plug
For connecting parameterising and service tools
Dimensions [mm]
129
20
152 72
172
224
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 37
SRFA-5
Rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC 24...240V / DC 24...125V
• Control: Open/Close
• SRFA-5: Deenergised NC
Technical data
Electrical data Nominal voltage AC 24...240V, 50/60Hz / DC 24...125V
Nominal voltage range AC 19.2...264V / DC 21.6...137.5V
Power In operation 7W @ nominal torque
consumption At rest 3.5W
For wire sizing 18VA
Connection Cable 1m, 2 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Direction of rotation Spring return
– SRFA-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 75s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power level Motor ≤45dB(A)
Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class II totally insulated
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1.AA
Rated impulse voltage 4kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2kg
Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage possible!
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
V7.3 08.2015• Subject to modification
• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.
38 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator with emergency function for rotary valves, AC
24...240V / DC 24...125V, 20Nm SRFA-5
Product features
Mode of operation The actuator is equipped with a universal power module and can process supply voltages
from AC 24...240V plus DC 24...125V.
The actuator moves the valve to the operating position at the same time as tensioning the
return spring. The valve is turned back to the safety position by spring force if the supply
voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.
Electrical installation
Wiring diagram NT ~L AC 24...240V
– + DC 24...125V
1 2
Notes
• Caution: Power supply voltage possible! !
Cable colours:
• Parallel connection of other actuators possible. 1 = blue
Note the performance data. 2 = brown
Dimensions [mm]
Dimensional drawings
59
101
27
103
40
162
172
182
244
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 39
SRFA-S2-5
Rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC 24...240V / DC 24...125V
• Control: Open/Close
• Two integrated auxiliary switches
• SRFA-S2-5: Deenergised NC
Technical data
Electrical data Nominal voltage AC 24...240V, 50/60Hz / DC 24...125V
Nominal voltage range AC 19.2...264V / DC 21.6...137.5V
Power In operation 7W @ nominal torque
consumption At rest 3.5W
For wire sizing 18VA
Auxiliary switch 2 x SPDT, 1 x 10% / 1 x 11...90%
Connection Motor Cable 1m, 2 x 0.75mm²
Auxiliary switch Cable 1m, 6 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Direction of Spring return
rotation – SRFA-S2-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 75s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power Motor ≤45dB(A)
level Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class II totally insulated
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1.AA.B
Rated impulse Actuator 4kV
voltage Auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.2kg
Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage possible!
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
V7.3 08.2015• Subject to modification
40 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator with emergency function for rotary valves,
AC 24...240V / DC 24...125V, 20Nm, with two auxiliary switches SRFA-S2-5
Product features
Mode of operation The actuator is equipped with a universal power module and can process supply voltages
from AC 24...240V plus DC 24...125V.
The actuator moves the valve to the operating position at the same time as tensioning the
return spring. The valve is turned back to the safety position by spring force if the supply
voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Flexible signalisation The actuator has one auxiliary switch with a fixed setting and one adjustable auxiliary
switch. They permit a 10% or 11...100% angle of rotation to be signalled.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.
Electrical installation
Wiring diagram N
T ~L
– +
230 V + 230 V
24 V + 24 V
230 V + 24 V
24 V + 230 V
Cable colours:
1 = blue
1 2 S1 S2 S3 S4 S5 S6 2 = brown
S1 = violet
Notes S2 = red
• Caution: Power supply voltage possible! ! S3 = white
• Parallel connection of other actuators possible. <A <B S4 = orange
A = 10% B = 11 ... 100% S5 = pink
Note the performance data. >A >B
S6 = grey
Dimensions [mm]
Dimensional drawings
59
101
27
103
40
162
172
182
244
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 41
SRF24A-SR-5
Modulating rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC/DC 24V
• Control: modulating DC (0)2...10V
• Position feedback DC 2...10V
• SRF24A-SR-5: Deenergised NC
Technical data
Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption In operation 5.5W @ nominal torque
At rest 3.5W
For wire sizing 8.5VA
Connection Cable 1m, 4 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Control Control signal Y DC (0)2…10V, input impedance 100k�
Operating range DC 2...10V
Position feedback (measuring voltage U) DC 2...10V, max. 0.5mA
Position accuracy ±5%
Direction of rotation Spring return
– SRF24A-SR-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 90s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power level Motor ≤45dB(A)
Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class III Extra low voltage / UL Class 2 Supply
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1.AA
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2kg
Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel.
All applicable legal or institutional installation regulations must be complied with.
V7.3 08.2015• Subject to modification
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.
42 UL marked actuators is optional, please contact your local Sales Representative for details.
Modulating rotary actuator with emergency function for
rotary valves, AC/DC 24V, 20Nm SRF24A-SR-5
Product features
Mode of operation The actuator is controlled with a standard signal of DC (0)2...10V and moves the valve to
the operating position at the same time as tensioning the return spring. The valve is turned
back to the emergency position by spring force if the supply voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.
Electrical installation
T ~
Wiring diagram
– +
Y DC
DC (0)2...10V
0 … 10 V
U DC 2...10V
DC 2 … 10 V
1 2 3 5
Notes Cable colours:
• Connect via safety isolation transformer. ! 1 = black
• Parallel connection of other actuators possible. 2 = red
Note the performance data. 3 = white
5 = orange
Direction of rotation NO NC
L R
Reversing switch
Y=0 Y=0
A – AB = 100%
Dimensions [mm]
Dimensional drawings
59
101
27
103
40
162
V7.3 08.2015• Subject to modification
172
182
244
UL marked actuators is optional, please contact your local Sales Representative for details. 43
GRK24A-5 / -7
SuperCap rotary actuator with emergency setting function and
extended functionalities for rotary valves with mounting flange
• Torque 40Nm
• Nominal voltage AC/DC 24V
• Control: Open/Close
• Design lifeSuperCaps 15 years
Technical data
Electrical data Nominal voltage AC 24V, 50/60 Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption In operation 11W @ nominal torque
At rest 3W
For wire sizing 21VA (lmax 20A @ 5ms)
Connection Cable 1m, 2 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque min. 40Nm @ nominal voltage
Emergency setting position (POP) NC / NO
Position accuracy ±5%
Manual override Gearing latch disengaged with push button
Running time Motor 150s / 90°
Emergency setting 35s @ 0...50°C
function
Sound power level Motor ≤52dB(A) @ 150s
Emergency setting ≤61dB(A)
function
Position indication Mechanical
Safety Protection class III Safety extra-low voltage
UL Class 2 Supply
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN
60730-2-14
Principle of operation Type 1.AA
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GRK24A-5 F05
GRK24A-7 F07
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.8kg
Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The switch for changing the direction of rotation may only be operated by authorised
personnel. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer's site. It does not contain any parts
V7.3 08.2015• Subject to modification
44 UL marked actuators is optional, please contact your local Sales Representative for details.
GRK24A-5 / -7
Product features
Mode of operation The actuator moves the valve to the desired operating position at the same time as the
integrated capacitors are loaded. Interrupting the supply voltage causes the valve to be
rotated back into the emergency setting position by means of stored electrical energy.
Pre-charging time (start up) The capacitor actuators require a pre-charging time. This time is used for charging the
capacitors up to a usable voltage level. This ensures that, in the event of an electricity in-
terruption, the actuator can be moved at any time from its current position into the preset
emergency setting position (POP).
The duration of the pre-charging time depends mainly on how long the power was inter-
rupted.
Typical pre-charging times 30 30
25 25
15 15
Duration of voltage interruption
[Days]
10 10
0 1 2 7 ≥10
Pre-charging
6 9 11 16 20
time [s] 5 5
0 0
0 2 4 6 8 10 12
Duration of voltage interruption [Days]
Delivery condition (capacitors) The actuator is completely discharged after delivery from the factory, which is why the
actuator requires approximately 20s pre-charging time before initial commissioning in
order to bring the capacitors up to the required voltage level.
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push button possible (the gear is disengaged for as long as the
button remains pressed down).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when
the end stop is reached.
Direction of rotation switch When actuated, the direction of rotation switch changes the running direction in normal
operation.
The direction of rotation switch has no influence on the emergency setting position
(POP) which has been set.
In case of changing the emergency position from NC to NO, it is mandatory necessary to
also change the direction of rotation switch.
Emergency setting position (POP) The «Emergency setting position» rotary button can be used to adjust the desired emer-
rotary button gency setting position (POP). The POP range is in reference to the maximum angle of
rotation of the actuator.
In the event of an voltage interruption, the actuator will move into the selected emer-
gency setting position, taking into account the bridging time (PF) of 2s which was set
ex-works.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 45
GRK24A-5 / -7
Wiring diagram
~
Wiring diagram
T
– +
Notes NC NO
• Connection via safety isolation transformer. ! A – AB = 0% A – AB = 100%
1 2
• Parallel connection of other actuators possible. POP POP
Note the performance data. Cable colours:
NO NC NO NC
1 = black
2 = red
POP button
NO NC
Status
(no function)
Disengagement button
LED display
Meaning / function
green
Illuminated Operation OK / without fault
Blinking POP function active
Off – Not in operation
– Pre-charging time SuperCap
– Fault SuperCap
A – AB
100 %
NO NC
POP
NO NC
Status A – AB
0%
NO NC
Dimensions [mm]
Dimensional drawings 44 174
102
8
∅6
V7.3 08.2015• Subject to modification
45°
124
99
50
69 214
46 UL marked actuators is optional, please contact your local Sales Representative for details.
GRK24A-MF-5 / -7
Modulating SuperCap rotary actuator with emergency control
function and extended functionalities for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC/DC 24V
• Control Modulating DC (0)2...10V
• Position feedback DC 2...10V
• Design life SuperCaps: 15 years
Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 11W
Power consumption in rest position 3W
Power consumption for wire sizing 21VA
Power consumption for wire sizing note Imax 20A @ 5ms
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 40Nm
Positioning signal Y DC 0...10V
Positioning signal Y note Input impedance 100kΩ
Operating range Y DC 2...10V
Operating range Y variable Start point DC 0.5...30V
End point DC 2.5...32V
Position feedback U DC 2...10V
Position feedback U note Max. 0.5mA
Position feedback U variable Start point DC 0.5...8V
End point DC 2.5...10V
Setting emergency position (POP) NC / NO or adjustable 0...100% (POP rotary
button)
Bridging time (PF) variable 1...10s
Position accuracy ±5%
Manual override Gear disengagement with push-button
Running time motor 150s / 90°
Running time emergency control position 35s / 90°
Adaption setting range manual (automatic on first power-up)
Sound power level motor 52dB(A)
Sound power level emergency control 61dB(A)
position
Position indication Mechanical
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1.AA
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GRK24A-MF-5 F05
GRK24A-MF-7 F07
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 47
GRK24A-MF-5 / -7 SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm
Safety notes
• This device has been designed for use in stationary heating, ventilation and air
! conditioning systems and is not allowed to be used outside the specified field of
application, especially in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• Cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be
disposed of as household refuse. All locally valid regulations and requirements must be
observed.
Product features
Mode of operation The actuator moves the valve to the desired operating position at the same time as the
integrated capacitors are loaded.
Interrupting the supply voltage causes the valve to be moved to the selected emergency
setting position (POP) by means of stored electrical energy.
Pre-charging time (start up) The capacitor actuators require a pre-charging time. This time is used for charging the
capacitors up to a usable voltage level. This ensures that, in the event of an electricity
interruption, the actuator can move at any time from its current position into the preset
emergency setting position (POP).
The duration of the pre-charging time depends mainly on following factors:
– Duration of the electricity interruption
– PF delay time (bridging time)
5s
20 2s 20
0s
15 15
10 10
5 5
Delivery condition (capacitors) The actuator is completely discharged after delivery from the factory, which is why the
actuator requires approximately 20s pre-charging time before initial commissioning in
order to bring the capacitors up to the required voltage level.
Parameterisable actuators The factory settings cover the most common applications. Input and output signals and
other parameters can be altered with the PC-Tool MFT-P or with the Service tool ZTH AP.
Simple Direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Manual override Manual control with push-button possible - temporary. The gear is disengaged and the
actuator decoupled for as long as the button is pressed.
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops
when the end stop is reached.
V7.3 08.2015• Subject to modification
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm
48 UL marked actuators is optional, please contact your local Sales Representative for details.
SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm GRK24A-MF-5 / -7
Product features
Home position The first time the supply voltage is switched on, i.e. at the time of commissioning, the
actuator carries out an adaption, which is when the operating range and position feedback
adjust themselves to the mechanical setting range.
The actuator then moves into the position defined by the positioning signal.
Factory setting: Y2 (counter-clockwise rotation).
Direction of rotation switch When actuated, the direction of rotation switch changes the running direction in normal
operation. The direction of rotation switch has no influence on the emergency setting
position (POP) which has been set.
Adaption and synchronisation An adaption can be triggered manually by pressing the „Adaption“ button or with the PC-
Tool. Both mechanical end stops are detected during the adaption (entire setting range).
Automatic synchronisation after pressing the gearbox disengagement button is configured.
The synchronisation is in the home position (0%).
The actuator then moves into the position defined by the positioning signal.
A range of settings can be adapted using the PC-Tool (see MFT-P documentation)
Rotary knob emergency setting The «Emergency setting position» rotary knob can be used to adjust the desired emergency
position setting position (POP). In the event of an electricity interruption, the actuator will move into
the selected emergency setting position, taking into account the bridging time (PF) of 2s
which was set ex-works.
Settings: The rotary knob must be set to the «Tool» position for retroactive settings of the
emergency setting position with the BELIMO service tool MFT-P. Once the rotary knob is set
back to the range 0…100%, the manually set value will have positioning authority
Bridging time (PF) Electricity interruptions can be bridged up to a maximum of 10s.
In the event of an electricity interruption, the actuator will remain stationary in accordance
with the set bridging time. If the electricity interruption is greater than the set bridging time,
then the actuator will move into the selected emergency setting position (POP).
The bridging time set ex-works is 2s. This can be modified on site in operation with the use
of the BELIMO service tool MFT-P.
Settings: The rotary knob must not be set to the «Tool» position!
Only the values need to be entered for retroactive adjustments of the bridging time with the
BELIMO service tool MFT-P.
Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Description Type
Service Tools Service Tool, for MF/MP/Modbus/LonWorks actuators and VAV- ZTH AP
Controller
Belimo PC-Tool, software for adjustments and diagnostics MFT-P
Electrical installation
Wiring diagrams
1 2 3 5 Cable colours:
1 = black
2 = red
3 = white
5 = orange
UL marked actuators is optional, please contact your local Sales Representative for details. 49
GRK24A-MF-5 / -7 SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm
Functions
Functions with basic values (conventional mode)
Override control with AC 24V with relay contacts Override control with AC 24V with rotary switch
~ ~
ZS 50%
T T
(DC 0...10 V)
Y
100%
0%
c Y (DC 0...10 V)
a b
a b c e.g. 1N 4007
0%
1 2 3 5 e.g. 1N 4007 1 2 3 5
ZS 50%
100%
Y U Y U
Y
e.g. 1N 4007
Y1 Y1
a b Y2 Y2
1 2 3 5 1 2 3 5
Y U Y U
50 UL marked actuators is optional, please contact your local Sales Representative for details.
SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm GRK24A-MF-5 / -7
Dimensions [mm]
Dimensional drawings 44 174
102
124
99
69 214
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 51
SY.. Large Torque Multi-function Actuators
Technical data
Nominal voltage AC 24V ± 10%
SY...-3-T, SY...-SR-T AC 230V ± 10%
Nominal voltage range AC 21.6...26.4V
SY...-3-T, SY...-SR-T 207...253V
Connecting cable ½” cable connector, screw terminals
Motor protection H class insulation (SY1), F class insulation (SY2...12)
Gear train High alloy steel gear sets
Control signal Y DC (0)2...10V
Sensitivity 200mV
Position feedback signal U DC (0)2...10V
Angle of rotation Electrically limited to 90°, Max. 95° for manual operation
Position indicator Top mounted domed indication
Auxiliary switches 2xSPDT 3A, AC 230V(SY1); 2xSPDT 5A, AC 230V(SY2...12)
Ambient temp. -20...+60°C
Humidity 5...95% RH, non-condensing
Degree of protection IP67
Housing material Die Cast Aluminium Alloy
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
* MP-T models available on request
Product Feature
Electrical connections All actuator control elements are wired to a terminal strip under the main cover. Remove the
cover and insert the cables through the cable connector in order to reach the terminal strip.
V7.3 08.2015• Subject to modification
The connectors should be made according to the diagram. Before beginning this procedure,
make sure that the power supply voltage is in accordance with the actuator’s name plate.
After the terminal connections have been made, move the actuator manually to the half-open
position and make a preliminary check of the wiring.
Overload protection If the real running torque exceeds the nominal torque, the overload protection will be
functioned to prevent the motor overload.
Manual operation The manual operation is available by turning a handwheel of actuators (SY2...12) and using
a 8mm wrench for SY1.
52 UL marked actuators is optional, please contact your local Sales Representative for details.
SY.. Large Torque Multi-function Actuators
Ordering sample
SY4 U230 -MF -T
Wiring diagrams
SY..-24-3-T Open/Close or 3-point control Terminal
Auxiliary switch
AC 24V A B C E F
T ~
#1 Power supply Com/Neutral
~ T
AC 24V
#4 Power supply Com/Neutral
Auxiliary switch
Notes: #5 Power supply Hot line
– + – + A BC E F
• Connection via safety isolating transformer. ! #6 Control signal -
53
SY.. Large Torque Multi-function Actuators
!
#4 Power supply Com/Neutral
WARNING! Leakage current is ~ T
AC 230V #5 Power supply Hot line
possible (<3.5mA)!
Connect the earth first before #6 Control signal -
Auxiliary switch
applying any supply voltage! #7 Control signal +
Disconnect the supply voltage – + – + A BC E F
#8 For actuator internal use
before the earth!
S1 100%
#9 For actuator internal use
U5 Feedback signal +
A B C D E F
T T
Notes: Y 1 U5 2 C1 C2 ┴2 Feedback signal -
S1 100% S2 0%
C1
V7.3 08.2015• Subject to modification
leave unconnected
C2
54
SY.. Large Torque Multi-function Actuators
Dimensions [mm]
øB
D D
A 1)
C C
øB øB
E
A A
C N-S F
F
øD
J E E
G
G
øH øH
IxM
øH N-S
IxM N-S
G IxM
C C
D D
N-S N-S
øB
øB
A
A F
E E
J J IxM
G
øH øK
øH
øK IxM G
Dim
A B C D E ΦF G H I J K M N S Flange type
Model No
SY1.. 150 1) 106 8 19 15 - 14 50 4 45° - M6 2 1/2 PS F05
SY2/3.. 255 2) 181 326 208 30 123 17/22 70 4 - 90 M8 2 1/2 PS F07
V7.3 08.2015• Subject to modification
SY4..6.. 317 217 394 294 40 194 22/35 102 4 - 125 M10 2 1/2 PS F10
SY7/8.. 406 217 347 336 45 295 36 140 4 45° 180 M16 2 1/2 PS F14
SY9...12.. 564 256 455 392 57 395 36 165 4 45° 221 M20 2 1/2 PS F16
55
SY.. Large Torque Multi-function Actuators
SY1U24-SR-T SY1U230-SR-T
Disconnect power supply •DIP switches setting
! before changing the follow-
ing settings.
Factory setting
8 7 6 5 4 3 2 1 Off
The words in bold are
default settings. On (Only available for SY1U24/230-SR-T)
When you need to adjust the signal of modulating board,
please adjust the VR1 and VR2:
S6 - Direction of S7 and S8 - Actuator
S1, S2 - for S3, S4, S5 - for
Travel in response response to the • VR2 adjusts 4mA, 2V, 1V (Fully-closed)
Input signal Output signal
to the control control signal failure • VR1 adjusts 20mA, 10V, 5V (Fully-open)
Input Output When sig-
S1 S2 S3 S4 S5 Symbol S6 S7 S8
signal signal nal fails Please turn the VR2 to the end by clockwise direction and
(0)2...10V Off On (0)2...10V On Off On 90
°
Fully closed Off On input 4mA to modulating board. Then please slightly turn
Off
Y the VR2 by counter-clockwise direction about 3...6 times
4...20mA On Off Fully open On Off
4...20mA Off On Off 90° until the RED light keeps ON.
On
1...5V Off Off Y Stop On On
•SW1 sensitive switch Please turn the VR1 to the end by counter clockwise direc-
Position “0”: Lowest sensitive, 0...90° divided into 17 steps.
tion and input 20mA to modulating board. Then please
Position “1”: Highest sensitive, 0...90° divided into 80 steps.
Prior to switch-on, make sure the input signal and voltage wiring are in slightly turn the VR1 by clockwise direction about 3...6
accordance with the actuator name plate and Dip-switch setting. times until the GREEN light keeps ON.
Service Jack
Connect to PC-Tool
Service Jack
Connect to PC-Tool
9, 10 5kΩ
Potentiometer
56
SY.. Large Torque Multi-function Actuators
Relationship of auxiliary switches, limiting switches and limits of manual rotation angle
Angle Range 1: Two auxiliary switches LS3 and LS4 are set at 3°...87° angle in the factory
Angle Range 2: The two limit switches LS2 and LS1 are set at 0°...90° angle in the factory
Angle Range 3: Two stop screws A and B are set at -2°...92° angle in the factory
57
SY.. Large Torque Multi-function Actuators
( C CW)
W)
diagram and initially tighten the cam;
TC1/TC3 (C
Current position
4. Check the full rotation of limit switch with power on;
TC1/TC3
Required position
5. Tighten the travel cam after successful re-adjustment, otherwise repeat to do point 3 and 4 until
the travel cam is successfully re-adjusted.
6. When the motor stops at fully closed or open position, tighten the corresponding stop screw ( CCW)
TC 2/TC4
until it touches the gearbox, turn the stop screw cycle back and lock by a hexagonal key and a Close
wrench (1 turn of the stop screw corresponding to 2° angle of rotation around). TC2/TC4 (C
W)
• The LS2/LS1 switches must always switch off the motor before the effect of stop screws.
• Perform an adaption after changing the position of the travel cam
Adaption button
Installation guidelines
FAQ
No operation Power supply or voltage abnormal Check the power supply voltage with the identification plate.
Fuse blown Check and replace the fuse as required (except for HW-CBPCB)
Tripping of motor thermal protective device Check if the motor is hot.The actuator will be available again
after the motor has cooled down. Solve the motor overheat
problem.
Running motor stops Power supply has short circuit Check wiring
External object stuck in the pipe Take off the valve for cleaning
Not fully opening/closing The fixing screw for travel cam is loose Re-adjust and tighten the travel cam
The actuator is continually The sensitivity setting is incorrect Adjust the sensitivity switch SW1 to increase the number (only
hunting for SY1..).
Occasional fail in motor Power input of ”open” and ”close” simultaneously Check if the external control switch is normal; relays are needed
switched on or off in parallel connection of several actuators
V7.3 08.2015• Subject to modification
58
D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo
Technical data
Flow medium Nylon coated disc Cold and hot water
SS304 disc Cold and hot water, Max. 50% glycol
Temperature of medium Nylon coated disc 0...+95°C
SS304 disc -20...+100°C
Nominal pressure 1600kPa (PN16)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
Max. Close-off pressure 1200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50...500)
Disc Nylon-coated ductile cast iron disc/ Stainless steel 304 disc
Seat EPDM
Shaft Stainless steel 416
Bushing RPTFE
Ordering sample
D6 125 MH D6 125 MW
Mode of operation
The Butterfly Valve is operated by a handle or a worm gear. Select the actuator according to
the required Close-off pressure and HVAC condition of installation. The discs are controlled
by manual operators.
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 59
Dimensions of D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo
D650...150..MH
Dimensions of PN10/16 Table E, wafer connection worm gear Butterfly Valves [mm]
D6350..MW DN350 78 328 422 256 345 81 213 300 - - 470 16-26 - - 51.6 50.2
D6400..MW DN400 102 374 473 294 377 120 251 400 - - 525 16-30 - - 84.4 86.6
D6450..MW DN450 114 425 526 337 422 120 251 400 - - 585 20-30 - - 100.8 102.9
D6500..MW DN500 127 472 582 375 466 124 254 300 - - 650 20-33 - - 134.5 131.4
60 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo
D650...150L..MH
PN16 NC SS
Type Size L C S H1 H2 H3 A BFV BFV
øD n-M (kg) (kg)
D650L..MH DN50 43 33 115 65 130 64 170 125 4-M16 2.8 2.8
D665L..MH DN65 46 48 132 71 143 64 170 145 4-M16 3.4 3.4
D680L..MH DN80 46 66 175 92 155 64 170 160 8-M16 4.5 4.4
D6100L..MH DN100 46 66 175 92 155 64 200 180 8-M16 6.4 6.2
D6125L..MH DN125 56 115 240 118 190 75 260 210 8-M16 8.8 8.4
D6150L..MH DN150 56 142 257 132 210 75 260 240 8-M20 10.4 9.7
PN16 NC SS
Type Size L C S H1 H2 H3 A øF BFV BFV
øD n-M (kg) (kg)
D650L..MW DN50 43 33 115 65 130 48 160 140 125 4-M16 4.1 4.1
D665L..MW DN65 46 48 132 71 143 48 160 140 145 4-M16 4.7 4.7
D680L..MW DN80 46 66 175 92 155 48 160 140 160 8-M16 5.8 5.7
D6100L..MW DN100 46 66 175 92 155 48 160 140 180 8-M16 7.5 7.3
D6125L..MW DN125 56 115 240 118 190 56 140 140 210 8-M16 11.9 11.6
D6150L..MW DN150 56 142 257 132 210 56 140 140 240 8-M20 13.5 12.9
D6200L..MW DN200 60 194 318 167 243 80 200 220 295 12-M20 21.1 19.8
D6250L..MW DN250 68 245 383 198 282 80 200 220 355 12-M24 30.4 28.2
D6300L..MW DN300 78 294 435 231 310 81 213 300 410 12-M24 44.0 46.1
V7.3 08.2015• Subject to modification
D6350L..MW DN350 78 328 512 256 345 81 213 300 470 16-M24 63.6 62.2
D6400L..MW DN400 102 374 590 294 377 120 251 400 525 16-M27 102.4 104.6
D6450L..MW DN450 114 425 640 337 422 120 251 400 585 20-M27 128.8 130.9
D6500L..MW DN500 127 472 703 375 466 124 254 300 650 20-M30 180.3 181.1
UL marked actuators is optional, please contact your local Sales Representative for details. 61
D6..AB Series Butterfly Valves
Trade Selection by Belimo
Technical data
Flow medium Sea water and brine
Temperature of medium Aluminium Bronze disc: -10...+80°C
Nominal pressure 1600kPa (PN16)
Flow characteristic Modified equal-percentage
Rangeability 10:1 (for 30°... 70° range)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...800)
Max. Close-off pressure 1200kPa (DN50...600)
1000kPa (DN700...800)
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50..800)
Disc Aluminium Bronze disc
Seat NBR
Shaft Stainless steel 416
Bushing RPTFE
Default: D6700..800AB Butterfly Valve and its Actuator are pre-calibrated and pre-assembled in the factory.
Ordering sample
D6 125 AB
Size: DN125
Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.
Mode of operation
The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/ Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.
Manual operation
The manual operation is available by using a lever with manual override button of SR..,
V7.3 08.2015• Subject to modification
62 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..AB Series Butterfly Valves
Trade Selection by Belimo
D650AB...D6600AB D6700AB...D6800AB
PN16
Type Size L C S H1 H2 4-M Weight (kg)
øD n-ød
D6700AB DN700 163 674 910 540 631 M33 840 20-36 391
D6800AB DN800 188 770 1025 607 674 M36 950 20-39 469.2
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 63
The Sizing of D6...AB Series Butterfly Valves
Trade Selection by Belimo
Kv Value [m3/h]
Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
D650AB DN50 2” 80 75 57 39 27 21 16 6.9 1.09
D665AB DN65 2.5” 170 142 99 64 42 30 19 7.5 5.2
D680AB DN80 3” 290 278 205 139 87 51 34 21 7.7
D6100AB DN100 4” 560 404 270 137 105 67 46 26 6.3
D6125AB DN125 5” 870 744 502 306 186 113 60 33 15.6
D6150AB DN150 6” 1340 1185 720 472 294 171 94 47 25.9
D6200AB DN200 8” 2690 2360 1483 956 617 362 211 88 52
D6250AB DN250 10” 5540 3948 2364 1502 911 588 334 193 84.5
D6300AB DN300 12” 7540 6147 3607 2083 1229 706 401 164 4.13
D6350AB DN350 14” 10300 9348 6233 3938 2380 1335 616 291 5.2
D6400AB DN400 16” 14300 12856 8571 5416 3237 1836 847 400 6.9
D6450AB DN450 18” 18900 17028 11352 7172 4334 2433 1122 530 9.5
D6500AB DN500 20” 24200 21893 14596 9222 5573 3128 1443 682 12
D6600AB DN600 24” 37169 33901 22549 14248 8611 4832 2230 1053 22
D6700AB DN700 28” 42672 30084 19628 12887 8621 5721 3137 1563 36
D6800AB DN800 32” 58836 41480 27065 17770 11886 7531 4130 2058 45
Ps Ps Ps
kPa kPa kPa
D650AB 1200 - -
D665AB 1200 - -
D680AB 1200 - -
D6100AB - 1200 -
D6125AB - - 1200
D6150AB - - 1200
Ps Ps Ps Ps Ps Ps Ps Ps Ps Ps
kPa kPa kPa kPa kPa kPa kPa kPa kPa kPa
D650AB 1200 - - - - - - - - -
D665AB 1200 - - - - - - - - -
D680AB 1200 - - - - - - - - -
D6100AB 1200 - - - - - - - - -
D6125AB - 1200 - - - - - - - -
D6150AB - 1200 - - - - - - - -
D6200AB - - 1200 - - - - - - -
D6250AB - - - 1200 - - - - -
D6300AB - - - 1200 - - - - - -
D6350AB - - - - 1200 - - - - -
D6400AB - - - - - 1200 - - - -
D6450AB - - - - - - 1200 - - -
D6500AB - - - - - - 1200 - -
V7.3 08.2015• Subject to modification
D6600AB - - - - - - - 1200 - -
D6700AB - - - - - - - - 1000 -
D6800AB - - - - - - - - - 1000
64 UL marked actuators is optional, please contact your local Sales Representative for details.
D6..D(S) Series Butterfly Valves
Trade Selection by Belimo
Technical data
Flow medium Nylon coated disc: Cold and hot water
SS304 disc: cold and hot water. Max. 50% Glycol
Temperature of medium Nylon-coated disc: Cold water and hot water, 0...+95°C
SS304 disc: -20...+100°C
Nominal pressure 1600kPa (PN16)
Leakage rate Rate A Bubble tight (ISO 5208)
Pipe connections * ISO 7005.2 PN16 wafer
Max. Close-off pressure 1200kPa (DN600)
1000kPa (DN700...1200)
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN600...1200)
Disc Nylon coated ductile cast iron disc / Stainless steel 304 disc
Seat EPDM
Stem Stainless steel 416
Bushing RPTFE
Default: D6700...1200D(S) Butterfly Valve and its Actuator are pre-calibrated and pre-assembled in the factory.
Ordering sample
D6 700 DS
Size: DN700
Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.
Mode of operation
The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.
Manual operation
The manual operation is available by turning a handwheel of actuators.
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 65
Dimensions of D6..D(S) Series Butterfly Valves
Trade Selection by Belimo
PN16 Weight
Type Size L C S H1 H2 4-M
øD n-ød (kg)
D6700D(S) DN700 163 674 910 540 631 M33 840 20-36 284
D6800D(S) DN800 188 770 1025 607 674 M36 950 20-39 368
D6900D(S) DN900 203 839 1125 656 720 M36 1050 24-39 713
D61000D(S) DN1000 216 939 1255 727 802 M39 1170 24-42 865
D61200D(S) DN1200 276 1124 1485 866 941 M45 1390 28-48 1545
Kv Value [m3/h]
Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
D6600D(S) DN600 24” 37169 33901 22549 14248 8611 4832 2230 1053 22
D6700D(S) DN700 28” 42672 30084 19628 12887 8621 5721 3137 1563 36
D6800D(S) DN800 32” 58836 41480 27065 17770 11886 7531 4130 2058 45
D6900D(S) DN900 36” 74461 52496 34251 22488 15042 9530 5227 2604 60
D61000D(S) DN1000 40” 103232 72780 47486 31178 20827 13195 7237 3606 84
D61200D(S) DN1200 48” 132284 92731 60851 39711 26457 16932 9259 4629 106
V7.3 08.2015• Subject to modification
66 UL marked actuators is optional, please contact your local Sales Representative for details.
The Sizing of D6..D(S) Series Butterfly Valves
Trade Selection by Belimo
UL marked actuators is optional, please contact your local Sales Representative for details. 67
D6.. H Series Butterfly Valves
Trade Selection by Belimo
Technical data
Flow medium Cold and hot water, Max. 50% glycol
Temperature of medium -20°C...+100°C
Nominal pressure 2500kPa (PN25)
Leakage rate Rate A Bubble tight (ISO 5208)
Pipe connections * ISO 7005.2 PN25 lug DN50...500
Max. Close-off pressure 2200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG50 (DN50...500)
Disc Stainless steel 304
Seat EPDM
Shaft Hardened and tempered 45 carbon steel
Bushing RPTFE
Default: D6500H Butterfly Valve and its actuator are pre-calibrated and pre-assembled in the factory.
Ordering sample
D6 125 H
Size: DN125
Mode of operation
The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.
Manual operation
The manual operation is available by turning a handwheel of actuators.
Kv Value [m3/h]
Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
D650H DN50 2” 117 108 78 55 39 21 10 4 0.1
D665H DN65 2.5” 190 176 125 85 56 32 17 7 0.2
D680H DN80 3” 261 238 158 100 61 34 19 10 0.3
D6100H DN100 4” 519 47 315 199 120 67 31 15 0.4
D6125H DN125 5” 884 804 536 339 205 115 53 25 0.7
D6150H DN150 6” 1366 1243 829 523 317 177 82 39 2
V7.3 08.2015• Subject to modification
68 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..H Series Butterfly Valves
Trade Selection by Belimo
D6350H - - - - - - - 2200 - - -
D6400H - - - - - - - - 2200 - -
D6450H - - - - - - - - - 2200 -
D6500H - - - - - - - - - - 2200
UL marked actuators is optional, please contact your local Sales Representative for details. 69
Complementary Products
Trade Selection by Belimo
Technical data
Electrical Data Nominal voltage AC 380V ±10% 3-PH, 50/60Hz*
Nominal voltage range AC 342...418V 3-PH, 50/60Hz
Connecting cable M33 cable connector, screw terminals
Motor protection F class
Gear train Steel
Control/Position feedback signal DC 4..20mA
Sensitivity 1% input signal
Angle of rotation 90°
Position indicator Top mounted domed indication
Ambient temp. QB.. -20°C..+50°C
XZA.. -20°C..+55°C
Humidity 5...95% RH, non-condensing
Degree of protection IP67
Manual Operation Manual by override handwheel
Housing material Cast iron
*3-phase AC 415V for QB../XZA.. actuator is available on request.
Motorpower for
Model Torque Running time 90° Running current Weight
reference Manual override
No. (Nm) (s) of motor (A) (kg)
(kW)
Ordering sample
QB8000 P -50
Model Number
V7.3 08.2015• Subject to modification
70 UL marked actuators is optional, please contact your local Sales Representative for details.
Complementary Products
Trade Selection by Belimo
Wiring diagrams
St op
Control method
Close
Local operation switch
Open
#5 Signal Remote
Auto 100% Switch Remote/Signal Remote
SO1 SC1 #6
Selection SSE1
Remote
Control method
Close
Local operation switch
Open
V7.3 08.2015• Subject to modification
UL marked actuators is optional, please contact your local Sales Representative for details. 71
Complementary Products
Trade Selection by Belimo
Dimensions [mm]
QB..
XZA..
Type L1 L2 L3 L4 B1 B2 H1 H2 H3 H4 H6 øF
XZA17500.. 197 580 98 1156 121 258 801 233 443 246 446 305
V7.3 08.2015• Subject to modification
XZA23000.. 248 580 98 1156 127 280 848 255 440 246 471 305
72 UL marked actuators is optional, please contact your local Sales Representative for details.
Butterfly Valves Installation Guideline and Recommendation
Recommended installation position The butterfly valves may be mounted either vertically
or horizontally.
The butterfly valves may not be installed in a hanging
position i.e. with the stem pointing downwards.
V7.3 08.2015• Subject to modification
73
Butterfly Valves Installation Guideline and Recommendation
INCORRECT CORRECT
Disc opened beyond valve body face. Disc positioned in the “almost closed” position.
Pipe flanges not spread sufficiently. Pipe flanges spread allowing sufficient room for valve.
Figure 2 Recommended Bolt Tightening Sequence
1 13
1 5 15 5
8 9 8
9
12 3 12 3
4 11 4 11
10 7 10 7
6 2 6 16
14 2
gaskets
INCORRECT CORRECT
Disc in “closed” position. Gaskets in- No flange gaskets used. Disc in the “almost
stalled between valve and mating flanges closed” position.
Figure 4 Final valve alignment and tightening of flange bolts
INCORRECT CORRECT
Pipe flanges mis-aligned. Uneven torque Piping aligned. Thread engagement even on
applied to bolting. both sides of valve.
Figure 5 Installation notes for DN700..1200 BFV
V7.3 08.2015• Subject to modification
INCORRECT CORRECT
Large size BFV with 2 flanges is wafer connected.
74
Butterfly Valves Installation Guideline and Recommendation
Valve Location: • Butterfly valves should be installed if possible a minimum of 6 pipe diameters from other
line elements, i.e., elbows, pumps etc.
• Where the butterfly valve is connected to a check valve or pump, use an expansion joint
between them to ensure the disc does interfere with the adjacent equipment.
W W
FLOW F FLOW
INCORRECT CORRECT
FLOW FLOW
Stem Stem
(Horizontal) (Vertical)
Suction Suction
INCORRECT CORRECT
FLOW FLOW
Stem Stem
(Horizontal) (Vertical)
Suction Suction
INCORRECT CORRECT
Stem Stem
(Horizontal) (Vertical)
FLOW FLOW
V7.3 08.2015• Subject to modification
INCORRECT CORRECT
75
Butterfly Valves Installation Guideline and Recommendation
Stem Stem
(Horizontal) (Vertical)
FLOW FLOW
INCORRECT CORRECT
Figure 3 Pipe Reducer
Stem Stem
(Horizontal) (Vertical)
FLOW FLOW
INCORRECT CORRECT
FLOW FLOW
INCORRECT CORRECT
Combination with all valve stems in the same Combination with stem of the control valve at right angle
direction accelerates possible noise, vibration and to those of other valves tends to cancel the drift of the
erosion problems. fluid, and reduces noises, vibration and erosion.
ISO 7005.2 DN D H DN D H
(mm) (mm) (mm) (mm) (mm) (mm)
GB/T 9113.1
50 50 4 50 50 4
GB/T 17241.6 65 65 4 65 65 4
80 80 4 80 80 4
100 100 4 100 100 4
125 125 4 125 125 4
150 150 4 150 150 4
200 208 5 200 208 5
250 250 6 250 255 6
300 308 6 300 308 6
350 340 7 350 340 7
400 405 7 400 405 7
450 455 8 450 455 8
500 505 8 500 505 8
- - - 600 605 8
V7.3 08.2015• Subject to modification
- - - 700 705 9
- - - 800 810 9
- - - 900 900 9
- - - 1000 1000 10
- - - 1200 1200 10
76
SR..A(-..)-5 Mounting Instructions
1 2
R6..W.. F05 = 14
2 BU6..
D6..
R6..W.. BU6..
D6..
1 2
100% 0%
F05
10Nm
10
D6..
BU6..
4
A M
B M
V7.3 08.2015• Subject to modification
C M
77
GR..A-5 / -7 Mounting Instructions
1 2
R6..W.. F05 = 14
F07 = 17
2 BU6..
D6..
R6..W.. BU6..
D6..
1 2
100% 0%
F05
10Nm
10
BU6..
D6..
F07
22Nm
13
4
A M
B M
20
C M
78
DR..A(-..)-7 Mounting Instructions
1 2
1
17
2 0%
F07
22Nm
13
V7.3 08.2015• Subject to modification
79
SRF(..)A(-..)-5 Mounting Instructions
NC NO
D6..
D6..
3 3
1 1
.9 9.
2 2
.8 8.
.7 7.
6 6
BU6.. BU6..
3 3
4x 4x
10
10
10 Nm 10 Nm
33 ... 100% NO NC
Y= 0 Y= 0
.9
.8
.7
.6
.5
.4
.3
.2 .1
V7.3 08.2015• Subject to modification
.2
.4
.6
.8
80
GRK..A(-..)-5 / -7 Mounting Instructions
1 R6..W.. 2
F05 = 14
F07 = 17
BU6..
2 D6..
1 2 R6..W.. BU6..
D6..
100% 0%
F05
10Nm
10
BU6..
D6..
F07
22Nm
13
4 1
M
2
V7.3 08.2015• Subject to modification
20
81
82
2
4
SY.. Mounting Instructions
45
3
2
83
SY(2...5)U24-SR/MF/MP-T / SY(2...9)U230-SR/MF-T Actuator
84
V7.3 08.2015• Subject to modification SY..-3-T Open/Close or 3-point Actuator
85
WD6S2 Linkage Kit Installation Instructions
86
Manual Handle and Worm Gear for Butterfly Valves
Trade Selection by Belimo
Applications
For manually operating D6..AB, D6..D(S) series
butterfly valves.
Technical data
Materials
Worm Gear Gear train Ductile cast iron and steel gear sets
Housing ZD6-W100~ZD6-W250 Cast Aluminium
ZD6-W350~ZD6-W1200 Cast Iron
Shaft Steel 45
Hand wheel Cast iron
Handle ZD6-H100~ZD6-H150 Cast Aluminium
Stop Plate Steel
Ordering sample
Dimensions [mm]
Manual Handle
Dimensions [mm]
Top Weight
Type
Flange (kg)
A HB HC
UL marked actuators is optional, please contact your local Sales Representative for details. 87
Manual Handle and Worm Gear for Butterfly Valves
Trade Selection by Belimo
Dimensions
Worm Gear
88 UL marked actuators is optional, please contact your local Sales Representative for details.
Market Asia Pacific
ASIA PACIFIC HEADQUARTERS Japan Office:
Belimo Actuators Ltd. Belimo Actuators Ltd.
Room 1601-6, 16/F, New Commerce Centre 2nd Floor, Yamaki Building III
19 On Sum Street, Shatin, N.T., Hong Kong 3-1-5 Azumabashi, Sumida-ku
Tel: +852 2687 1716 Tokyo 130-0001, Japan
Fax: +852 2687 1795 Tel: +81 3 6823 6961
E-mail: info.asiapacific@belimo.ch Fax: +81 3 3626 3911
E-mail: info.japan@belimo.ch
Belimo AUSTRALIA
Melbourne Office: Malaysia Office:
Belimo Actuators Pty. Ltd. Belimo Actuators Ltd
12 Enterprise Court S-13-12, First Subang, Jalan SS15/4G
Mulgrave Business Park 47500 Subang Jaya, Selangor, Malaysia
Mulgrave, VIC 3170, Australia Tel: +03-56125833
Tel: +61-(0)3-8585 7800 Fax: +03-56125233
Fax: +61-(0)3-8585 7811 E-mail: info.malaysia@belimo.ch
E-mail: info.australia@belimo.ch Singapore Office
Belimo Actuators Ltd.
Sydney Office: 1 Tannery Road #08-04
Belimo Actuators Pty. Ltd. One Tannery, Singapore 347719
Suite 2.20, 32 Delhi Road Tel: +65 6842 1626
North Ryde, NSW 2113, Australia Fax: +65 6842 1630
Tel: +61 (0)2 9805 1777 E-mail: info.singapore@belimo.ch
Fax: +61 (0)2 9805 1722
E-mail: info.australia@belimo.ch Taiwan Office:
Belimo Actuators Ltd.
Belimo CHINA 7F-2, No.343, Jhonghe Rd., Yonghe District
Shanghai Office: New Taipei City 234, Taiwan
Belimo Actuators (Shanghai) Trading Ltd. Tel: +886 2 2922 8805
479 Chun Dong Road, Building C-2 Fax: +886 2 2922 8806
Xin Zhuang Industry Park E-mail: info.taiwan@belimo.ch
Shanghai 201108, P.R. China
Thailand Office:
Tel: +86 21 5483 2929
Belimo Actuators Ltd.
Fax: +86 21 5483 2930
90/2 Pensiri Place, Soi Phaholyothin 32
E-mail: info.shanghai@belimo.ch
Phaholyothin Road, Chandrakasem, Jatujak
Beijing Office: Bangkok 10900, Thailand
Belimo Actuators Ltd. Tel: +662 9415582-3
Unit 1528-1530, 15F, Tower A Fax: +662 9415584
Jiatai International Mansion E-mail: info.thailand@belimo.ch
No. 41, Middle East Fourth Ring Road
Chaoyang District, Beijing,100025, Belimo INDIA
P.R. China Mumbai Office:
Tel: +86 10 6462 1382/1386 Belimo Actuators India Pvt. Ltd.
Fax: +86 10 6462 1383 23/ ABCD, Govt. Industrial Estate, Charkop
E-mail: info.beijing@belimo.ch Kandivali West, Mumbai 400067, India
Tel: +91 22 4025 4800
Guangzhou Office: Fax: +91 22 4025 4899
Belimo Actuators Ltd. E-mail: info.india@belimo.ch
Room 5217-5218, China International Centre,
Tower B, 33 Zhong Shan San Road, Yuexiu District, Bangalore office:
Guangzhou 510055, P.R. China Belimo Actuators India Pvt. Ltd.
Tel: +86 20 3435 1860 Sreerama Complex, No. 13, 2nd Floor
Fax: +86 20 3435 1870 5th Cross Road, 6th Block, Koramangala
E-mail: info.guangzhou@belimo.ch Bangalore – 560097, India
Tel: +91-80-40906311
Belimo HONG KONG Fax: +91-80-40906288
Hong Kong Office: E-mail: info.india@belimo.ch
Belimo Actuators Ltd.
New Delhi Office:
Room 1601-6, 16/F, New Commerce Centre
Belimo Actuators India Pvt. Ltd.
19 On Sum Street, Shatin, N.T., Hong Kong
Flat No. 515, DLF Tower – B
Tel: +852 2687 1716
Jasola Distt. Centre, Jasola
Fax: +852 2687 1795
New Delhi 110025, India
E-mail: info.hongkong@belimo.ch
Tel: +91 11 41078501
Fax: +91 11 41078508
Indonesia Office:
E-mail: info.india@belimo.ch
Belimo Actuators Ltd.
Graha Kencana Building 8th Floor Block B Chennai Office:
Jl. Raya Perjuangan 88 Belimo Actuators India Pvt. Ltd.
Kebon Jeruk - Jakarta Barat 11530, Indonesia Flat no.3B, Urmilla House
Tel: +62 21 5367 8278 #15, ARK Colony, Eldams Road
Fax: +62 21 5366 0688 Chennai-600 018, India
E-mail: info.indonesia@belimo.ch Tel: +91 44 24355154/5153
E-mail: info.india@belimo.ch
89
Innovation, Quality
and Consultancy:
Fire &
Smoke A partnership for
motorising HVAC
actuators
Damper
PICCV
EPIV
EV
CCV
Butterfly
Valve
93010-00171
Globe
Valve
EU BELIMO Automation AG AP Belimo Actuators Ltd. US BELIMO Aircontrol (USA), Inc. Or contact your nearest Sales Representative
Brunnenbachstrasse 1 Room 1601-6, 16/F, New Commerce Centre 33 Turner Road
8340 Hinwil, Switzerland 19 On Sum Street, Shatin, N.T., Hong Kong Danbury, CT 06810
Tel: +41 43 843 61 11 Tel: +852 2687 1716 USA
Fax: +41 43 843 62 68 Fax: +852 2687 1795 Tel: +800 543-9038 / 203 791-9915
E-mail: info@belimo.ch E-mail: info.asiapacific@belimo.ch Fax: +800 228-8283 / 203 791-9919 www.belimo.com