You are on page 1of 90

Butterfly Valves

Technical Databook Version 7.3


BFV and Actuators Product Range Overview and
Applications
page 4
BU6..Series Motorised Butterfly Valves
–– BU6..Series Butterfly Valves
–– General Rotary Actuators
–– Mechanical Fail-Safe Rotary Actuators
–– Electronic Fail-Safe Rotary Actuators
–– Large Torque Multi-function Actuators page 6
D6..MH/MW Series for Manual Applications
–– D6..MH/MW Series Butterfly Valves
–– Dimensions and Sizing Chart

page 59
D6..AB Series for Sea Water Media Applications
–– D6..AB Series Butterfly Valves
–– Dimensions and Sizing Chart

page 62
D6..D(S) Series for Large Size Pipe Applications
–– D6..D(S) Series Butterfly Valves
–– Dimensions and Sizing Chart

page 65
D6..H Series for High Close-off Pressure Applications
–– D6..H Series Butterfly Valves
–– Dimensions and Sizing Chart

page 68
Complementary Products
–– QB..
–– XZA..

page 70

Butterfly Valve Installation Guideline and Recommendation

page 73

Actuators Mounting Instruction Sheets

page 77
Appendix

–– Manual Operator
–– ZD6..
page 83
Contents

BFV and Actuators


BFV and Actuators Product Range 4
Overview and Applications
BU6..Series Motorised Butterfly Valves
BU6.. Series Product Overview 6
The Sizing of BU6.. Series Butterfly Valves 8
BU6.. Series Butterfly Valves, Wafer and Lug Pattern 10
Dimensions of BU6.. Series Butterfly Valves 11
General Rotary Actuators
SR..A(-..)-5 12
GR..A-5/-7 22
DR..A(-..)-7 29
DR24A-MP-7 32
Mechanical Fail-Safe Rotary Actuators
SRF(..)A(-..)-5 38
Electronic Fail-Safe Rotary Actuators
GRK..A(-..)-5/-7 44
SY..Large Torque Multi-function Actuators 52
D6..MH/MW Series for Manual Applications
D6..MH/MW Series Butterfly Valves 59
Dimensions and Sizing Chart 60
D6..AB Series for Sea Media Applications
D6..AB Series Butterfly Valves 62
Dimensions and Sizing Chart 63
D6..D(S) Series for Large Size Pipe Applications
D6..D(S) Series Butterfly Valves 65
Dimensions and Sizing Chart 66
D6..H Series for High Close-off Pressure Applications
D6..H Series Butterfly Valves 68
Dimensions and Sizing Chart 69
Complementary Products
QB..and XZA.. 70
Butterfly Valve Installation Guideline and
73
Recommendation
Mounting Instructions 77
Appendix 83
V7.3 08.2015• Subject to modification

3
BFV and Actuators Product Range Overview and Applications

BFV and Actuators product range overview

Product Range Valves Applications Actuators


Standard 2-way Motorised Butterfly Valve • Media: Cold and hot water, glycol • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SR..A..-5, GR..A..-5/-7, DR..A..-7,
• General HVAC application DN50...500,1600kPa and SY series
• Material: • Max. Close-off pressure: 1200kPa • Fail-Safe control function: SRF(..)
Ductile cast iron body • Temperature: 0...+95°C A..-5, GRK..A..-5/-7
EPDM seat -20...+100°C
Nylon coated/Stainless steel disc • Pipe connection:
Stainless steel shaft PN10/16 and Table E for wafer
(DN50...300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)

Complementary 2-way Motorised Butterfly Valve* • Media: Sea water, brine • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SR..A..-5, GR..A..-5/-7, DR..A..-7,
• Special for sea water or brine media DN50...800,1600kPa and SY and QB* series
• Material: • Max. Close-off pressure:
Ductile cast iron body 1200kPa (DN50...600)
NBR seat 1000kPa (DN700...800)
Aluminium bronze disc • Temperature: -10...+80°C
Stainless steel shaft • Pipe connection:
PN10/16 and Table E for wafer
(DN50...300)
PN16 for wafer (DN350...800)
Complementary 2-way Motorised Butterfly Valve* • Media: Cold and hot water, glycol • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SY and QB* series
• Special for large size pipe DN600...1200,1600kPa
• Material: • Max. Close-off pressure:
Ductile cast iron body 1200kPa (DN600)
EPDM seat 1000kPa (DN700...1200)
Nylon coated/Stainless steel disc • Temperature: -20...+100°C
Stainless steel shaft • Pipe connection: PN16 for wafer

Complementary 2-way Motorised Butterfly Valve* • Media: Cold and hot water, glycol • General Rotary Actuators:
• Shut off or control function • Nominal size and pressure: SY and QB* series
• Special for high Close-off pressure DN50...500,2500kPa
• Material: • Max. Close-off pressure: 2200kPa
Ductile cast iron body • Temperature: 0...+95°C
EPDM seat -20...+100°C
Stainless steel disc • Pipe connection:
Carbon steel shaft ISO 7005.2 PN25 for lug
(DN50...500)
Manual Butterfly Valve* • Media: Cold and hot water, glycol • Handle and worm gear:
• Shut off or control function • Nominal size and pressure: ZD6.. series
• General HVAC application DN50...500,1600kPa
• Material: • Max. Close-off pressure: 1200kPa
Ductile cast iron body • Temperature: 0...+95°C
EPDM seat -20...+100°C
Nylon coated/Stainless steel disc • Pipe connection:
Stainless steel shaft PN10/16 and Table E for wafer
(DN50...300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
*Trade selection by Belimo

Pressure - Temperature Chart

2500
Range A Nylon coated disc plus EPDM seat
2200 BU6.., D6..D, D6..MH/MW
2000
Max. Close-off Pressure (kPa)

1800

1600
1400
Application Range
1200

1000

800
600
V7.3 08.2015• Subject to modification

400
200
0

-20 -10 0 20 40 60 80 100 120

Media Temperature ( °C)

4 UL marked actuators is optional, please contact your local Sales Representative for details.
BFV and Actuators Product Range Overview and Applications

Pressure - Temperature Chart

HVAC Medium Temperature Close-off Pressure HVAC Medium


Application
Material -20...+100°C 0...1200kPa Water Sea Water Glycol
EPDM X
Seat
NBR -10...+80°C
Nylon 0...+95°C X
Disc Stainless Steel (SS304) X
Aluminium Bronze

EPDM NBR
2500 Stainless Steel Disc 2500
2200 2200

2000 2000

1800 1800

Pressure (kPa)
Pressure (kPa)

1600 1600

1400 N
Nylon Coated
a Discc 1400

1200 1200

1000 1000

800 800

600 600 Aluminium Bronze Disc


400 400

200 200
0 0

-20 0 20 40 60 80 100 120 -20 -10 0 20 40 60 80 100 120

Temperature ( °C) Temperature ( °C)

Product Series Medium Close-off Pressure(kPa) Temp. of media(°C)

Seat + Disc Water Sea water Glycol 2200 1200 600 400 -20 -10 0 80 100
Standard Motorised NC BU6.. Series*
Large Size Motorised NC D6..D Series EPDM + NC X
Manual NC D6..MH/MW
Standard Motorised SS BU6.. S*
Large Size Motorised SS D6..DS
EPDM + SS304 X
PN25 Motorised SS D6..H
Manual SS D6..SMH/SMW
Sea Water D6..AB NBR + AB
*BU6200X/LX, BU6200SX/LSX is utilised at 600kPa only.

Excellent Good Poor X Not recommended

Reference Standard:

ISO 10631: Metallic Butterfly Valves for General Purposes


JIS B2032: Wafer type rubber-seated Butterfly Valves
ASME B16.34: Valves — Flanged, Threaded and Welding End
ISO 5208: Industrial Valves - Pressure Testing of Valves
EN 593: Industrial Valves - Metallic Butterfly Valves
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 5
BU6.. Series Product Overview

Butterfly Valves and Rotary Actuators for Open/Close or modulating control


Nylon coated ductile cast iron disc (BU6..series)
Key features
Nominal pressure: 1600kPa Other technical data see page 8...11
Kvs[m /h]3
80 170 290 560 870 1340 2690 5540 7540 10300 14300 18900 24200

DN[mm] 50 65 80 100 125 150 200 250 300 350 400 450 500
Wafer

BU6.. BU650 BU665 BU680 BU6100 BU6125 BU6150 BU6200.. BU6250 BU6300 BU6350 BU6400 BU6450 BU6500
Type

Lug

BU6..L BU650L BU665L BU680L BU6100L BU6125L BU6150L BU6200L.. BU6250L BU6300L BU6350L BU6400L BU6450L BU6500L

kv
SR24A(-S)-5 GR..A..-5 GR..A..-7 DR..A..-7
SR230A(-S)-5 GRK..A..-5 GRK..A..-7
IP54 SRFA-5
Y SRFA-S2-5

With Open/
SY1-24-3-T SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8..
Close
IP67 SY1-230-3-T
actuator
kv SR24A-SR-5 GR..A..-5 GR..A..-7 DR..A..-7
IP54 SRF24A-SR-5 GRK..A..-5 GRK..A..-7

With SY1U24-SR-T
IP67 SY1U230-SR-T
SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8..
Modulating
actuator
Note: Stainless Steel disc (BU6..S series) is available on request.

V7.3 08.2015• Subject to modification

6
BU6.. Series Product Overview

Belimo BU6..series Butterfly Valves are designed to meet the stringent needs Belimo General Rotary Actuators, Fail-Safe Rotary Actuators designed for
of HVAC applications requiring positive shut-off for liquids. BU6.. Series BFV.

Valve design features Belimo SRF..A..-5, GRK..A..-5/-7, SR..A..-5, GR..A..-5/-7, DR..A..-7 series
2 Rotary Actuators use the best possible electric motors and gearings and
1 also employ highly sophisticated electronics for the control. The universal
product design makes installation, operation and service much easier.
3

5 4
GR..A..-5 /-7
7
6

9 10

1. Mounting flange according to ISO 5211. To satisfy higher IP requirement and large size butterfly automation, Belimo
2. Square shaft head for form-fit attachment of the Rotary Actuator. offers SY..series Rotary Actuators which are designed to mate with the
3. Shaft with EPDM O-ring seal. BU6..series Butterfly Valves and other quarter-turn valve applications.
4. RPTFE shaft bearing.
SY.. Actuator design features
5. Full series of valve body made of ductile cast iron (DN50...500).
6. Hole pattern for PN10/16, Table E (wafer, DN50...300)
9
PN16 (wafer DN350...500, Lug DN50...500)
7. Shaft made of stainless steel 416. 7
8. Double-D-fit attachment of the shaft to the disc.
8
9. The disc made of ductile cast iron nylon coated or stainless steel 304.
10. EPDM seat symmetrical, integrated flange sealing.

• Double-D-fit of two pieces of non-pin shaft connected with disc, a more


compact and strong structure, can produce 4-way self-adjusting centralisa- 4
tion thanks to its unique design and optimise and minimise interference-fit, 5
resulting in low operation torque.
• Innovative double supports of trench seat can ensure positive assembly 6
among the valve body, seat and disc, and can keep rotation of disc smooth
-going consistently minimising compressional deformation and seat brushing
off.
1 3
• Advanced ball profile of disc with narrow sealing belt can provide isolation 2
of HVAC flow media from valve body by double-prevention and can eliminate
internal leakage and reduce seat tearing or fatiguing due to bunching. The
primary seal is achieved by an interference-fit of the molded seat flat with the
disc hub. The secondary seal is created when the shaft diameter is greater
than internal shaft hole.
• The nylon-coated disc features excellent anti-corrosion and low friction
coefficient with exact casting, precision machining and advanced coated 1. Gearbox with hardened planetary gear.
process which gives a smooth rotation and close disc-to-seat relationship. 2. Two stop screws for limiting of manual operation.
The stainless steel disc is a rust proof with hand polishing process which 3. Handwheel that acts directly on the planetary gear.
can decrease operation torque for actuator and withstand higher HVAC flow 4. Motor protected by a thermostat.
media temperature. 5. Terminals.
• Three anti-corrosion RPTFE (Reinforced Poly Tetra Fluoro Ethylene), 6. Two limit switches and two auxiliary switches.
EPDM O-ring (made of Ethylene-Propylene-Diene Monomer) and stainless 7. Housing made of cast aluminium (IP67).
steel shaft circlip completely isolate flow media from top flange, synchronise 8. 4xM5 hexagonal screws for cover of housing.
rotation between shaft and disc, decrease operation torque and ensure 9. Sight glass for position indicator (rotary cylinder).
extreme long life cycle.
• The patented gear drive mechanism provides efficient, smooth operation
• Meet stringent and extensive HVAC flow media with wide and circular while allowing easy manual override at any time.
arc flange sealing surface, which can be suitable for all flange connection
• With IP67 rating, easily visible position indicator, international standard
standard as ISO, JIS, AS without additional gasket in AP easily and efficiently.
ISO 5211 mounting system, internal thermal motor overload protection,
heater, two auxiliary switches and easily accessible wiring termination
points.
• The units are easily visible in mechanical rooms with their characteristic
Belimo orange color. Wiring diagrams included in all printed documentation
are also affixed to the outside of the housing on the permanently attached
product label.
V7.3 08.2015• Subject to modification

• The torque ranges are available from 35...3500Nm.

7
The Sizing of BU6..Series Butterfly Valves

Kv Value [m3/h]

Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
BU650.. DN50 2” 80 75 57 39 27 21 16 6.9 1.09
BU665.. DN65 2.5” 170 142 99 64 42 30 19 7.5 5.2
BU680.. DN80 3” 290 278 205 139 87 51 34 21 7.7
BU6100.. DN100 4” 560 404 270 137 105 67 46 26 6.3
BU6125.. DN125 5” 870 744 502 306 186 113 60 33 15.6
BU6150.. DN150 6” 1340 1185 720 472 294 171 94 47 25.9
BU6200.. DN200 8” 2690 2360 1483 956 617 362 211 88 52.0
BU6250.. DN250 10” 5540 3948 2364 1502 911 588 334 193 84.5
BU6300.. DN300 12” 7540 6147 3607 2083 1229 706 401 164 4.13
BU6350.. DN350 14” 10300 9348 6233 3938 2380 1335 606 291 5.2
BU6400.. DN400 16” 14300 12856 8571 5416 3237 1836 847 400 6.9
BU6450.. DN450 18” 18900 17028 11352 7172 4334 2433 1122 530 9.5
BU6500.. DN500 20” 24200 21893 14596 9222 5573 3128 1443 682 12
Note: the maximum velocity in the butterfly valve is 6m/s (for Open/Close control).

Max. Close-off Pressure △Ps and linkage — BU6.. series

IP54 Actuator (Indoor Use)

Type

SR..A..-5 GR..A..-5 GR..A..-7 DR..A..-7


[20Nm] [40Nm] [40Nm] [90Nm]
Ps Ps Ps Ps
kPa kPa kPa kPa
BU650, BU650L, BU650S, BU650LS 1200 - - -
BU665, BU665L, BU665S, BU665LS 1200 - - -
BU680, BU680L, BU680S, BU680LS 1200 - - -
BU6100, BU6100L, BU6100S, BU6100LS - 1200 - -
BU6125, BU6125L, BU6125S, BU6125LS - - 1200 -
BU6150, BU6150L, BU6150S, BU6150LS - - - 1200

IP54 Fail-Safe Rotary Actuator (Indoor Use)

Type

SRF(..)A..-5 GRK..A..-5 GRK..A..-7


[20Nm] [40Nm] [40Nm]
△Ps △Ps △Ps
kPa kPa kPa
BU650, BU650S, BU650LS 1200 - -
BU665, BU665S, BU665LS 1200 - -
BU680, BU680S, BU680LS 1200 - -
BU6100, BU6100S, BU6100LS - 1200 -
BU6125, BU6125S, BU6125LS - - 1200
V7.3 08.2015• Subject to modification

8
The Sizing of BU6..Series Butterfly Valves

Max. Close-off Pressure △Ps and linkage — BU6.. series (continued)

IP67 Actuator (Outdoor Use)


SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8..
Type [35Nm] [90Nm] [150Nm] [400Nm] [650Nm] [1000Nm] [1500Nm]
△Ps △Ps △Ps △Ps △Ps △Ps △Ps
kPa kPa kPa kPa kPa kPa kPa
BU650, BU650L, BU650S, BU650LS 1200 - - - - - -
BU665, BU665L, BU665S, BU665LS 1200 - - - - - -
BU680, BU680L, BU680S, BU680LS 1200 - - - - - -
BU6100, BU6100L, BU6100S, BU6100LS 1200 - - - - - -
BU6125, BU6125L, BU6125S, BU6125LS - 1200 - - - - -
BU6150, BU6150L, BU6150S, BU6150LS - 1200 - - - - -
BU6200, BU6200L, BU6200S, BU6200LS - - 1200 - - - -
BU6250, BU6250L, BU6250S, BU6250LS - - - 1200 - - -
BU6300, BU6300L, BU6300S, BU6300LS - - - 1200 - - -
BU6350, BU6350L, BU6350S, BU6350LS - - - - 1200 - -
BU6400, BU6400L, BU6400S, BU6400LS - - - - - 1200 -
BU6450, BU6450L, BU6450S, BU6450LS - - - - - - 1200
BU6500, BU6500L, BU6500S, BU6500LS - - - - - - 1200
V7.3 08.2015• Subject to modification

9
BU6.. Series Butterfly Valves, Wafer or Lug Pattern

2-way Butterfly Valves flanged

DN50...500

For Open/Close or modulating control of cold and hot water.


Applications
Typical applications include chiller isolation, cooling tower
isolation, change-over systems, air handling unit, fan coil
control, bypass and process control.

Technical data
Flow medium Nylon coated disc: Cold and hot water
SS304 disc: cold and hot water. Max. 50% Glycol
Temperature of medium Nylon-coated disc: 0...+95°C
SS304 disc: -20...+100°C
Nominal pressure 1600kPa (PN16)
Flow characteristic Modified equal-percentage
Rangeability 10:1 (for 30°... 70° range)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
Max. Close-off pressure 1200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50...500)
Disc Nylon coated ductile cast iron disc / Stainless steel 304 disc
Seat EPDM
Shaft Stainless steel 416
Bushing RPTFE

Ordering sample
BU6 125 L / GR230A-7
Actuator: GR230A-7 actuators, Open/Close,
AC 100...240V
Default: Only SY Actuators and its Butterfly Valves are pre-
calibrated and pre-assembled in the factory
Package: “/” Valve and actuator supplied separately on request
Disc and flange* L(X)-Lug, Nylon coated disc
pattern: default(X)-Wafer, Nylon coated disc
LS(X)-Lug, stainless steel disc
S(X)-Wafer, stainless steel disc
Size: DN125
Butterfly Valve: BU6.. Low torque series
* BU6200X/LX, BU6200SX/LSX is utilised at 600kPa only.

Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.

Mode of operation
The BU6.. series Butterfly Valves are operated by General Rotary Actuators, Mechanical
Fail-Safe Rotary Actuators or SY Large Torque Multi-function Actuators are available. Select
the actuators according to required Close-off pressure and HVAC condition of installation.
The actuators are controlled by a standard Open/Close or modulating control system and
rotate the disc of the valve to the position dictated by the control signal.
V7.3 08.2015• Subject to modification

Manual operation
The manual operation is available by using a lever with manual override button of SR..,
GR.., DR.. actuator pressed or turning a handwheel of actuators.

10 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of BU6.. Series Butterfly Valves
Wafer connection Lug connection

Dimensions of PN10/16, Table E wafer connection Butterfly Valve [mm]

Top PN10 PN16 Table E NC BFV SS BFV


Type Size L C S H1 H2 H3 H4 G ød1
flange (kg) (kg)
øD n-ød øD n-ød øD n-ød
BU650.. DN50 F05 43 33 118 65 130 13 9 14 65 125 4-18 125 4-18 114 4-18 2.0 2.0
BU665.. DN65 F05 46 48 135 71 143 13 9 14 65 145 4-18 145 4-18 127 4-18 2.4 2.4
BU680.. DN80 F05 46 66 149 92 155 13 9 14 65 160 8-18 160 8-18 146 4-18 2.8 2.7
BU6100.. DN100 F05 52 91 150 104 170 13 11 14 65 180 8-18 180 8-18 178 8-18 4.3 4.1
BU6125.. DN125 F07 56 115 176 118 190 19 13 17 90 210 8-18 210 8-18 210 8-18 6.6 6.2
BU6150.. DN150 F07 56 142 204 132 210 19 13 17 90 240 8-22 240 8-22 235 8-22 7.7 7.6
BU6200.. DN200 F07 60 194 260 167 243 19 15 17 125 295 8-22 295 12-22 292 8-22 13.3 12.0
BU6250.. DN250 F10 68 245 316 198 282 24 17 22 125 350 12-22 355 12-26 356 12-22 20.9 19.7
BU6300.. DN300 F10 78 294 372 231 310 24 17 22 125 400 12-22 410 12-26 406 12-26 28.9 31.0
BU6350.. DN350 F10 78 328 422 256 345 24 20 22 125 - - 470 16-26 - - 42.5 41.1
BU6400.. DN400 F14 102 374 473 294 377 38 21 36 175 - - 525 16-30 - - 63.7 65.9
BU6450.. DN450 F14 114 425 526 337 422 38 21 36 175 - - 585 20-30 - - 80.1 82.2
BU6500.. DN500 F14 127 472 582 375 466 38 22 36 210 - - 650 20-33 - - 107.5 104.4

Dimensions of PN16 lug connection Butterfly Valve [mm]

Top PN16 NC BFV SS BFV


Type Size L C S H1 H2 H3 H4 G ød1
flange øD n-M (kg) (kg)

BU650L.. DN50 F05 43 33 115 65 130 13 9 14 65 125 4-M16 2.5 2.5


BU665L.. DN65 F05 46 48 132 71 143 13 9 14 65 145 4-M16 3.1 3.1
BU680L.. DN80 F05 46 66 175 92 155 13 9 14 65 160 8-M16 4.2 4.1
BU6100L.. DN100 F05 52 91 195 104 170 13 11 14 65 180 8-M16 5.9 5.7
BU6125L.. DN125 F07 56 115 240 118 190 19 13 17 90 210 8-M16 8.1 7.8
BU6150L.. DN150 F07 56 142 257 132 210 19 13 17 90 240 8-M20 9.7 9.1
BU6200L.. DN200 F07 60 194 318 167 243 19 15 17 125 295 12-M20 16.8 15.5
BU6250L.. DN250 F10 68 245 383 198 282 24 17 22 125 355 12-M24 26.1 23.9
BU6300L.. DN300 F10 78 294 435 231 310 24 17 22 125 410 12-M24 34.9 37.0
BU6350L.. DN350 F10 78 328 512 256 345 24 20 22 125 470 16-M24 54.5 53.1
BU6400L.. DN400 F14 102 374 590 294 377 38 21 36 175 525 16-M27 81.7 83.9
BU6450L.. DN450 F14 114 425 640 337 422 38 21 36 175 585 20-M27 108.1 110.2
V7.3 08.2015• Subject to modification

BU6500L.. DN500 F14 127 472 703 375 466 38 22 36 210 650 20-M30 153.3 154.1

UL marked actuators is optional, please contact your local Sales Representative for details. 11
SR24A-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC/DC 24V
• Control Open/Close, 3-point

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.2W
Power consumption for wire sizing 5.5VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.

Product features
V7.3 08.2015• Subject to modification

Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.

12 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC/DC 24V, 20Nm SR24A-5

Product features
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Electrical installation

Notes • Connection via safety isolating transformer.


! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

Wiring diagrams

AC/DC 24V, Open/Close AC/DC 24V, 3-point


T ~ T ~
– + – +

1 2 3 1 2 3

Y1 Y1

Y2 Y2 Y2 Y2 Y1
Cable colours: Cable colours:
1 = black 1 = black
Y2 2 = red Y2 2 = red
A – AB = 0% 3 = white A – AB = 0% 3 = white

Dimensions [mm]
Dimensional drawings 33 118
84
93
V7.3 08.2015• Subject to modification

70
176 108 43

UL marked actuators is optional, please contact your local Sales Representative for details. 13
SR24A-SR-5

Rotary actuator for rotary valves


• Nominal torque 20Nm
• Nominal voltage AC/DC 24V
• Control Modulating DC (0)2...10V
• Position feedback DC 2...10V

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.4W
Power consumption for wire sizing 5VA
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Positioning signal Y DC (0)2...10V
Positioning signal Y note Input impedance 100kΩ
Operating range Y DC 2...10V
Position feedback U DC 2...10V
Position feedback U note Max. 1mA
Position accuracy ±5%
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
V7.3 08.2015• Subject to modification

• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.

Product features
Mode of operation The actuator is connected with a standard modulating signal of DC (0)2...10V and travels to
the position defined by the positioning signal. Measuring voltage U serves for the electrical
display of the valve position 0...100% and as slave control signal for other actuators.

14 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Modulating, AC/DC 24V, 20Nm SR24A-SR-5

Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-onT ~ P2800A
Feedback potentiometer 5 kOhm, – add-on
+ P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Y DC (0)2...10V
U DC 2...10V
Electrical installation
1 2 3 5
Notes • Connection via safety isolating transformer.
! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch
Y1
is covered. Factory setting: Direction of rotation Y2.
Y2
Wiring diagrams
AC/DC 24V, modulating Override control (frost protection circuit)
T ~ T ~
– + – +
Y DC (0)2...10V
Y DC (0)2...10V c d
U DC 2...10V

1 2 3 5 Cable colours: 1 2 3 5 Cable colours:


1 = black 1 = black
2 = red 2 = red
Y1 Y1
3 = white 3 = white
Y2 5 = orange Y2 5 = orange
c d Y1 / Y2

Y1 A – AB = 100%

Y2 A – AB = 0%
T ~ DC (0)2...10 V
– +
Y DC (0)2...10V
Dimensions c[mm]
d

Dimensional drawings 33 118


1 2 3 5

Y1

Y2
84

c d Y1 / Y2

Y1 A – AB = 100%

Y2 A – AB = 0%
DC (0)2...10 V
V7.3 08.2015• Subject to modification

93

70
176 108 43

UL marked actuators is optional, please contact your local Sales Representative for details. 15
SR230A-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC 230V
• Control Open/Close, 3-point

Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 3W
Power consumption in rest position 0.6W
Power consumption for wire sizing 7VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, integrated, two-section
Safety Protection class IEC/EN II Protective insulated
Protection class UL II Protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 4kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning

! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage!
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
V7.3 08.2015• Subject to modification

Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
16 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC 230V, 20Nm SR230A-5

Product features
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Electrical installation

Notes • Caution: Power supply voltage!


! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

Wiring diagrams

AC 230V, Open/Close AC 230V, 3-point


N L N L

1 2 3 1 2 3

Y1 Y1

Y2 Y2 Y2 Y2 Y1
Cable colours: Cable colours:
1 = blue 1 = blue
Y2 2 = brown Y2 2 = brown
A – AB = 0% 3 = white A – AB = 0% 3 = white

Dimensions [mm]
Dimensional drawings 33 118
84
93
V7.3 08.2015• Subject to modification

70
176 108 43

UL marked actuators is optional, please contact your local Sales Representative for details. 17
SR24A-S-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC/DC 24V
• Control Open/Close, 3-point
• With integrated auxiliary switch

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 2.5W
Power consumption in rest position 0.2W
Power consumption for wire sizing 5.5VA
Auxiliary switch 1 x SPDT, 0...100%
Switching capacity auxiliary switch 1mA...3 (0.5) A, AC 250 V (II Protective
insulated)
Connection supply / control Cable 1m, 3 x 0.75mm²
Connection auxiliary switch Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Rated impulse voltage auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Mechanical data F05
Weight Weight Approx. 1kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning

! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
V7.3 08.2015• Subject to modification

of as household refuse. All locally valid regulations and requirements must be observed.

Product features
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting
position in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).

18 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Cose, 3-point, AC/DC 24V, 20Nm SR24A-S-5

Product features
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
Flexible signalisation With adjustable auxiliary switch (0...100%)
Auxiliary switch
1 1
S1 S2 S3 S1 S2 S3

0 0

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Electrical installation

Notes • Connection via safety isolating transformer.


! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

Wiring diagrams
AC/DC 24V, Open/Close AC/DC 24V, 3-point
T ~ T ~
– + – +

1 2 3 S1 S2 S3 1 2 3 S1 S2 S3
Cable colours: Cable colours:
Y1 1 = black 1 = black
Y1
Y2 0 ... 100%
2 = red Y2 Y1 2 = red
Y2 0 ... 100%
3 = white Y2 3 = white
Y2 S1 = violet S1 = violet
A – AB = 0% S2 = red Y2 S2 = red
S3 = white A – AB = 0% S3 = white

Dimensions [mm]
33 117
Dimensional drawings
84
21
V7.3 08.2015• Subject to modification

93

70
176 150

UL marked actuators is optional, please contact your local Sales Representative for details. 19
SR230A-S-5
Rotary actuator for rotary valves
• Nominal torque 20Nm
• Nominal voltage AC 230V
• Control Open/Close, 3-point
• With integrated auxiliary switch

Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 3W
Power consumption in rest position 0.6W
Power consumption for wire sizing 7VA
Auxiliary switch 1 x SPDT, 0...100%
Switching capacity auxiliary switch 1mA...3 (0.5) A, AC 250V (II Protective
insulated)
Connection supply / control Cable 1m, 3 x 0.75mm²
Connection auxiliary switch Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 20Nm
Manual override Gear disengagement with push-button, can be
locked
Running time motor 90s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanically, pluggable
Safety Protection class IEC/EN II Protective insulated
Protection class UL II Protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 4kV
Rated impulse voltage auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F05
Weight Weight Approx. 1kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning

! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage!
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
V7.3 08.2015• Subject to modification

that can be replaced or repaired by the user.


• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.

20 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator, Open/Close, 3-point, AC 230V, 20Nm SR230A-S-5

Product features
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting
position in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops when
the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
Flexible signalisation With adjustable auxiliary switch (0...100%)
Auxiliary switch
1 1
S1 S2 S3 S1 S2 S3

0 0

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Electrical installation
Notes • Caution: Power supply voltage!
• Parallel connection of other actuators possible. Observe the performance data.
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

Wiring diagrams
AC 230V, Open/Close AC 230V, 3-point
N L T ~
– +

1 2 3 S1 S2 S3
Cable colours: 1 2 3 S1 S2 S3 Cable colours:
1 = blue 1 = blue
Y1 2 = brown 2 = brown
Y2
Y2
0...100% 3 = white Y1
3 = white
Y2 Y1 0 ... 100%
S1 = violet Y2 S1 = violet
Y2 S2 = red S2 = red
A – AB = 0% S3 = white Y2 S3 = white
A – AB = 0%

Dimensions [mm]
33 117
Dimensional drawings
84
21
V7.3 08.2015• Subject to modification

93

70
176 150

UL marked actuators is optional, please contact your local Sales Representative for details. 21
GR24A-5 / -7
GR24A-5 Rotary actuator for rotary valves
GR24A-7 Rotary actuator for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC/DC 24V
• Control Open/Close

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 19.2...28.8V
Power consumption in operation 4W
Power consumption at rest 2W
Power consumption for wire sizing 6VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor GR24A-5 min. 40Nm
GR24A-7 min. 40Nm
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Rated current voltage motor 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GR24A-5 F05
GR24A-7 F07
Weight Weight Approx. 1.85kg

Safety notes

• This device has been designed for use in stationary heating, ventilation and air conditioning

! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.

Product features
V7.3 08.2015• Subject to modification

Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.

22 UL marked actuators is optional, please contact your local Sales Representative for details.
GR24A-5 / -7

Product features
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Wiring diagram

Notes • Connection via safety isolating transformer.


! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

GR24A-5/-7
AC/DC 24V, Open/Close
T ~ T ~
– + – +

1 2 3 1 2 3

Y1 Y1
Y2 Y2 Y1
Y2 Y2
Cable colours:
1 = black
Y2 2 = red Y2
A – AB = 0% 3 = white A – AB = 0%

Dimensions [mm]
GR24A-5/-7 210
97

6/ 8
124
V7.3 08.2015• Subject to modification

47.5°
69 174

UL marked actuators is optional, please contact your local Sales Representative for details. 23
GR24A-SR-5 / -7
Modulating rotary actuator for rotary valves
GR24A-SR-5 with mounting flange ISO 5211-F05
GR24A-SR-7 with mounting flange ISO 5211-F07
• Torque 40Nm
• Nominal voltage AC/DC 24V
• Control: modulating DC(0) 2...10V
• Position feedback DC 2...10V

Technical data
Electrical data Nominal voltage AC 24V, 50/60 Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power In operation 4.5W @ nominal torque
consumption At rest 1.5W
For wire sizing 6.5VA
Connection Cable 1m, 4 x 0.75mm²
Parallel operation Possible, note the performance data
Functional data Torque (nominal torque) Min. 40Nm @ nominal voltage
Control Control signal Y DC (0)2...10V, typical input impedance 100kΩ
Operating range Y DC 2...10V
Position feedback DC 2...10V, max. 1mA
Position accuracy ±5%
Manual override Gearing latch disengaged with pushbutton,
can be locked
Running time 150s / 90°
Sound power level Max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection EMA/UL NEMA 2, UL Enclosure Type 2
EMC CE in accordance with 2004/108/EU
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature 0...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange GR24A-SR-5 F05
GR24A-SR-7 F07
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.5kg

Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air conditioning
! systems and is not allowed to be used outside the specified field of application, especially
in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during assembly.
• The switch for changing the direction of rotation may only be operated by authorised per-
sonnel. The direction of rotation must not be reversed in a frost protection circuit.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
V7.3 08.2015• Subject to modification

• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.

24 UL marked actuators is optional, please contact your local Sales Representative for details.
GR24A-SR-5 / -7

Product features
Mode of operation The actuator is controlled with a standard modulating signal of DC (0)2...10V and travels to
the position defined by the control signal. Measuring voltage U serves for the electrical dis-
play of the actuator position 0...100% and as slave control signal for other actuators.
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position in
relation to the fitting can be selected in 90° steps.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Wiring diagram
GR24A-SR-5 Standard connection Override control (Frost protection circuit)
T ~ T ~
Notes – + – +
• Connect via safety isolation transformer. ! Y DC
DC (0)2...10V
0 ... 10 V Y DC
DC (0)2...10V
0 ... 10 V
• Other actuators can be connected in parallel. No- Control of controller c d Control of controller
te performance data for supply.
U DC 2 ... 10 V
• Direction of rotation switch is covered. Measuring voltage
Factory setting: Direction of rotation Y2 for reset signal

1 2 3 5 1 2 3 5 Cable
colours:
1 = black
2 = red
Direction of rotation Y1 3 = white
Y2
5 = orange
c d Actuator Butterfly valve
Y1 A – AB = 100%
Y2 A – AB = 0%
Modulating operation

GR24A-SR-7 Standard connection Override control (Frost protection circuit)


T ~ T ~
Notes – + – +
• Connect via safety isolation transformer. ! DC
Y DC (0)2...10V
0 ... 10 V Y DC
DC (0)2...10V
0 ... 10 V
• Other actuators can be connected in parallel. No- Control of controller c d Control of controller
te performance data for supply.
U DC 2 ... 10 V
• Direction of rotation switch is covered. Measuring voltage
Factory setting: Direction of rotation Y2 for reset signal

Cable
V7.3 08.2015• Subject to modification

1 2 3 5 1 2 3 5
colours:
1 = black
Direction of rotation Y1 2 = red
3 = white
Y2 5 = orange
c d Actuator Butterfly valve
Y1 A – AB = 100%
Y2 A – AB = 0%
Modulating operation
UL marked actuators is optional, please contact your local Sales Representative for details. 25
GR24A-SR-5 / -7

Dimensions [mm]
GR24A-SR-5 44 151

98
133
0
R1

59 141 43

GR24A-SR-7 44 151

98
133
0
R1

59 141 43
V7.3 08.2015• Subject to modification

26 UL marked actuators is optional, please contact your local Sales Representative for details.
GR230A-5 / -7
GR230A-5 Rotary actuator for rotary valves
GR230A-7 Rotary actuator for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC 230V
• Control Open/Close

Technical data
Electrical data Nominal voltage AC 230V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 85...265V
Power consumption in operation 5W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection supply / control Cable 1m, 3 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor GR230A-5 min. 40Nm
GR230A-7 min. 40Nm
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Mechanical, pluggable
Safety Protection class IEC/EN II protective insulated
Protection class UL II protective insulated
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
Electromagnetic compatibility CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Rated current voltage motor 4kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GR230A-5 F05
GR230A-7 F07
Weight Weight Approx. 1.85kg

Safety notes
• This device has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be disposed
V7.3 08.2015• Subject to modification

of as household refuse. All locally valid regulations and requirements must be observed.

Product features
Manual override Manual override with push-button possible (the gear is disengaged for as long as the button
is pressed or remains locked).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
UL marked actuators is optional, please contact your local Sales Representative for details. 27
GR230A-5 / -7

Product features
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form-fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form-fit coupling of the rotary actuator.
- Hole circle d = 70mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Wiring diagram

Notes • Caution: Power supply voltage!


• Parallel connection of other actuators possible. Observe the performance data.
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

GR230A-5/-7
AC 230V, Open/Close
N L N L

1 2 3 1 2 3

Y1 Y1
Y2 Y2 Y1
Y2 Y2
Cable colours:
1 = blue
Y2 2 = brown Y2
A – AB = 0% 3 = white A – AB = 0%

Dimensions [mm]
44 151
GR230A-5/-7
98

V7.3 08.2015• Subject to modification


133
0
R1

59 141 43

28 UL marked actuators is optional, please contact your local Sales Representative for details.
DR..A(-SR)-7 Rotary Actuator
DR24A(-SR)-7 Rotary actuator for butterfly valves
• Nominal torque 90Nm
• Nominal voltage AC/DC 24V
• Open/Close Control: DR24A-7
• Modulating Control: DR24A-SR-7

DR230A-7 Rotary actuator for butterfly valves


• Nominal torque 90Nm
• Nominal voltage AC 100...240V
• Control Open/Close

Technical data
Basc technical data Nominal voltage frequency 50/60Hz
Parallel operation No
Torque motor Max. 90Nm (not constant)
Manual override Gear disengagement with push-button, can be locked
Running time motor 150s / 90°
Sound power level motor max. 45dB(A)
Position indication Yes
Degree of protection IEC/EN IP54
EMC CE according to 2004/108/EC
Certification IEC/EN Certified to IEC/EN 60730-1 and
IEC/EN 60730-2-14
Mode of operation Type 1
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Connection flange F07
Weight Approx. 3.6kg
DR24A-7 Nominal voltage AC/DC 24V
Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V
Power consumption in operation 4.5W
Power consumption at rest 2W
Power consumption for wire sizing 7VA
Connection Cable 1m, 3 x 0.75mm²
Protection class IEC/EN III Safety extra-low voltage
Rated current voltage 0.8kV
DR24A-SR-7 Nominal voltage AC/DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 7W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection Cable 1m, 4 x 0.75mm²
Protection class IEC/EN III Safety extra-low voltage
Rated current voltage 0.8kV
DR230A-7 Nominal voltage AC 100...240V
Nominal voltage range AC 85...265V
Power consumption in operation 5W
Power consumption at rest 2W
Power consumption for wire sizing 9VA
Connection Cable 1m, 3 x 0.75mm²
Protection class IEC/EN II totally insulated
Rated current voltage 4kV
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 29
DR..A(-SR)-7 Rotary Actuator

Safety notes
• This actuator has been designed for use in stationary heating, ventilation and air-conditioning
systems and is not allowed to be used outside the specified field of application, especially
! in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may not be adjusted.
• The angle of rotation is not permitted to be subjected to mechanical limitation. It is forbidden
to alter the mechanical end stops.
• The device may only be opened at the manufacturer’s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• For DR24A-7, the device contains electrical and electronic components and is not allowed
to be disposed of as household refuse. All locally valid regulations and requirements must
be observed.
• For DR230A-7, caution: power supply voltage!

Product features
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Direct mounting Simple direct mounting on the butterfly valves with ISO 5211-F07 mounting flange. The
mounting orientation with reference to the butterfly valve can be selected in 90° (angle) steps.
Manual override For DR24A-7, Manual operation is possible with the push-button (the gearing latch remains
disengaged as long as the push-button is pressed or detented).
For DR24A-SR-7, manual override with push-button possible (the gear is disengaged for as
long as the button is pressed or remains locked).
For DR230A-7, manual override with push-button possible (the gear is disengaged for as
long as the button is pressed or remains locked).
Mode of operation For DR24A-SR-7, the actuator is connected with a standard modulating signal of DC 0 ...
10V and travels to the position defined by the positioning signal. The measuring voltage U
serves for the electrical display of the actuator position 0 ... 100% and as slave control signal
for other actuators.

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

Wiring diagram

Notes • Connection via safety isolating transformer.


! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

DR24A-7
AC/DC 24V, Open/Close
T ~
– +

1 2 3
V7.3 08.2015• Subject to modification

Y1
Y2
Y2
Cable colours:
1 = black
Y2 2 = red
A – AB = 0% 3 = white

30 UL marked actuators is optional, please contact your local Sales Representative for details.
DR..A(-SR)-7 Rotary Actuator
T ~
Wiring diagram – +
Y DC 0 ... 10 V
Notes • Connection via safety isolating transformer. c d
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

DR24A-SR-7 1 2 3 5
AC/DC 24V, modulating AC/DC 24V, modulating, override control
T ~ T ~
– + – + Y1
Y DC 0 ... 10 V
Y DC 0…10 V c d Y2

U DC 2…10 V c d Y1 / Y2

Y1 A – AB = 100%

1 2 3 5 1 2 3 5 Y2 A – AB = 0%
Cable colours: DC 0...10 V
1 = black
Y1 2 = red
Y1
3 = white
Y2 5 = orange Y2

c d Y1 / Y2

Y1 A – AB = 100%
DR230A-7 Y2 A – AB = 0%
DC 0...10 V
AC 230V, Open/Close
N L

1 2 3

Y1
Y2
Y2
Cable colours:
1 = blue
Y2 2 = brown
A – AB = 0% 3 = white

Dimensions [mm]
72 146 41
DR24A-7

DR24A-SR-7

DR230A-7
129
20

152 72
172
V7.3 08.2015• Subject to modification

224

UL marked actuators is optional, please contact your local Sales Representative for details. 31
DR24A-MP-7 Rotary Actuator
Communicative rotary actuator for butterfly valves
• Nominal torque 90Nm
• Nominal voltage AC/DC 24V
• Control Modulating: DC (0)2...10V variable
• Position feedback: DC 2...10V variable
• Communication via Belimo MP-Bus
• Conversion of sensor signals

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 9W
Power consumption at rest 2W
Power consumption for wire sizing 12VA
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation No
Functional data Torque motor max. 90Nm (not constant)
Positioning signal Y DC 0...10V
Positioning signal Y note Input impedance 100kΩ
Control signal Y variable Open/Close
3-point (AC only)
Modulating (DC 0...32V)
Operating range Y DC 2...10V
Operating range Y variable Start point DC 0.5...30V
End point DC 2.5...32V
Position feedback U DC 2...10V
Position feedback U note Max. 0.5mA
Position feedback U variable Start point DC 0.5...8V
End point DC 2.5...10V
Position accuracy ±5%
Manual override Gear disengagement with push-button, can be
locked
Running time motor 150 s / 90°
Motor running time variable 75...290 s
Automatic adjustment of operating Automatic adaptation of operating range and
range to match the mechanical feedback to match the mechanical angle of
angle of rotation rotation:Manual triggering of the adaption by
pressing the «Adaption» button or with the PC-Tool
Override control MAX (maximum position) = 100%
MIN (minimum position) = 0%
ZS (intermediate position, AC only) = 50%
Override control variable MAX = (MIN + 30°)...100%
MIN = 0%...(MAX – 30°)
ZS = MIN...MAX
Sound power level motor max. 45dB(A)
Position indication Yes
Safety Protection class IEC/EN III Safety extra-low voltage
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
V7.3 08.2015• Subject to modification

Ambient temperature -30...50°C


Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange F07
Weight Weight Approx. 3.6kg

32 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator

Safety notes
• This device has been designed for use in stationary heating, ventilation and air
conditioning systems and is not allowed to be used outside the specified field of
! application, especially in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may not be adjusted.
• The angle of rotation is not permitted to be subjected to mechanical limitation. It is
forbidden to alter the mechanical end stops.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• The cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be
disposed of as household refuse. All locally valid regulations and requirements must be
observed.

Product features
Mode of operation Conventional operation:
The actuator is connected with a standard modulating signal of DC 0...10V and travels
to the position defined by the positioning signal. The measuring voltage U serves for the
electrical display of the actuator position 0...100% and as slave control signal for other
actuators.
Operation on the MP-Bus:
The actuator receives its digital positioning signal from the higher level controller via
the MP-Bus and travels to the position defined. Connection U serves as communication
interface and does not supply an analogue measuring voltage.
Converter for sensors Connection option for a sensor (passive or active sensor or switching contact). The MP
actuator serves as an analogue/digital converter for the transmission of the sensor signal
via MP-Bus to the higher level system.
Parameterisable actuators The factory settings cover the most common applications. Input and output signals and
other parameters can be altered with the PC-Tool MFT-P or with the Service tool ZTH AP.
Direct mounting Simple direct mounting on the butterfly valve. The mounting orientation in relation to the
butterfly valve can be selected in 90° (angle) increments.
Manual override Manual override with push-button possible (the gear is disengaged for as long as the
button is pressed or remains locked).
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops
when the end stop is reached.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm
Home position The actuator moves to the home position when the supply voltage is switched on for the
first time, i.e. at the time of commissioning or after pressing the «gear disengagement»
key.
Factory setting: Y2 (counter-clockwise rotation).
The actuator then moves into the position defined by the positioning signal.

Y2 A – AB = 0%

Y1 A – AB = 100%

Accessories
Description Type

Electrical accessories Gateway MP for BACnet MS/TP, AC/DC 24 V S1A


Gateway MP to Modbus RTU, AC/DC 24 V
Gateway MP for LonWorks®, AC/DC 24 V, LonMark-certified
Gateway MP to KNX/EIB, AC/DC 24 V, EIBA certified
Connecting board MP bus suitable for wiring boxes EXT-WR-FP..-MP
MP-Bus power supply for MP actuators, AC 230/24V for local power supply
V7.3 08.2015• Subject to modification

Auxiliary switch, add-on, 1 x SPDT


Auxiliary switch, add-on, 2 x SPDT
Feedback potentiometer 140 Ohm, add-on
Feedback potentiometer 200 Ohm, add-on
Feedback potentiometer 500 Ohm, add-on
Feedback potentiometer 1 kOhm, add-on
Feedback potentiometer 2.8 kOhm, add-on
Feedback potentiometer 5 kOhm, add-on
Feedback potentiometer 10 kOhm, add-on
UL marked actuators is optional, please contact your local Sales Representative for details. 33
DR24A-MP-7 Rotary Actuator

Accessories (continued)
Description Type

Service Tools Service Tool, for MF/MP/Modbus/LonWorks actuators and VAV-Controller ZTH AP
Belimo PC-Tool, software for adjustments and diagnostics MFT-P
Adapter to Service-Tool ZTH MFT-C
ZIP-USB-MP interface ZIP-USB-MP

Wiring diagram
Notes • Connection via safety isolating transformer.
! • Direction of rotation switch is covered. Factory setting: Direction of rotation Y2.

Wiring diagrams

AC/DC 24V, modulating Operation on the MP-Bus


T ~ T ~
– + – +

Y DC (0)2...10 V Y Sensor
U DC 2...10 V U MP

13 25 Cable colours: 13 25 Cable colours:


1 = black 1 = black
2 = red 2 = red
3 = white 3 = white
5 = orange 5 = orange

Functions

Functions when operated on MP-Bus

Connection on the MP-Bus Power topology


T ~
– + MP

A)

There are no restrictions for the


1 2 3 5 network topology (star, ring, tree or
mixed forms are permitted).
Supply and communication in one
and the same 3-wire cable
Y U A) more actuators and sensors • no shielding or twisting necessary
(max.8) • no terminating resistors required

Connection of active sensors Connection of external switching contact

T ~ T ~
– + MP – + MP

A) A)

A) more actuators and sensors


A) more actuators and sensors (max.8)
1 2 3 5 1 2 3 5
(max.8) • Switching current 16mA @
• Supply AC/DC 24V 24V
V7.3 08.2015• Subject to modification

• Output signal DC 0...10V • Start point of the operating


Y U (max. DC 0...32V) Y U range must be parameterised
• Resolution 30mV on the MP actuator as ≥ 0.6V

34 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator

Functions
Connection of passive sensors
T ~
– + MP

12 35 Ni1000 –28...+98°C 850...1600 2)

2)
PT1000 –35...+155°C 850...1600
Y U 1) Depending on the type
NTC –10...+160°C 1) 2)
2) Resolution 1Ohm

Functions with basic values (only in conventional mode)

Override control with AC 24V with relay contacts Override control with AC 24V with rotary switch
T ~ T ~
Y (DC 0...10 V)

c Y (DC 0...10 V)

2 3 e.g. 1N 4007
a b 1 4

e.g. 1N 4007
ab c Pos
0% 10 %
1 2 35 ZS 50% 1 2 35 2 ZS 50%
100% 3 100%
Y U Y U
Y 4 Y

Remote control 0...100% positioner SG.. Minimum limit with positioner SG..
T ~ T ~
T ~ SGA24 T ~ SGA24
Y Z SGF24 Y Z SGF24
1 2 3 4 SGE24 1 2 3 4 SGE24
Y [V]
10

Y (DC 0...10 V)
min
1 2 35 1 2 35

Y U Y U 0 [%
0 100

Follow-up control (position-dependent) Position indication


T ~ T ~
– + – + ZAD24
Y DC (0)2...10 V 1 2 3 4
1)

U DC 2...10 V
V7.3 08.2015• Subject to modification

1 2 35 1 2 35 1 2 35

Y U Y U Y U
(1) Adapting the direction of rotation

UL marked actuators is optional, please contact your local Sales Representative for details. 35
DR24A-MP-7 Rotary Actuator

Functions
Follow-up control (position-dependent) Position indication

T ~
– +
T ~
500 – +
(–)
4...20 mA
(+)

Procedure
U DC 2...10 V
1. Connect 24V to connections 1 and 2
2. Disconnect connection 3:
Caution: – with direction of rotation 0: Actuator
1 2 35 The operating range must be 1 2 35 rotates to the left
set to DC 2...10V. – with direction of rotation 1: Actuator
The 500Ω resistor converts the rotates to the right
Y U 4...20mA current signal to a Y U 3. Short-circuit connections 2 and 3:
voltage signal DC 2...10V – Actuator runs in opposite direction

Functions for actuators with specific parameters (Parametrisation with PC-Tool necessary)

Override control and limiting with AC 24V Override control and limiting with AC 24V
with relay contacts with rotary switch
T ~ T ~
Close 1)

Y (DC 0...10 V)
Open
Y (DC 0...10 V)
MAX
e
MIN
ZS

ab cd e.g. 1N 4007

e.g. 1N 4007
ab cd e
Close 1)
MIN
12 3 5 ZS 12 3 5
MAX 1) Caution: This function is only
guaranteed if the start point of
Y U Open Y U the operating range is defined as
Y min. 0.6V.

Control Open/Close AC/DC 24V, 3-point


T ~ T ~
– +

a b
e.g. 1N 4007

U U
ab
1 2 3 5 12 3 5
stop

Y U Y U
V7.3 08.2015• Subject to modification

36 UL marked actuators is optional, please contact your local Sales Representative for details.
DR24A-MP-7 Rotary Actuator

Operating controls and indicators

1 Direction of rotation switch


Y1 Switch over: Direction of rotation changes
1 2 Push-button and LED display green
Y2 Off: No power supply or malfunction
On: In operation
Adaption 2 Press button:Triggers angle of rotation adaption followed by standard operation
Power
3 Push-button and LED display yellow
Address 3 Off: Standard mode without MP bus
Status Flickering: MP communication active
On: Adaption or synchronising process active
4 Flashing: Addressing request sent to MP master
Press button: Acknowledgment of addressing
4 Gear disengagement button
Press button: Gear disengaged, motor stops, manual operation possible
5 Release button:Gear engaged, synchronisation starts, followed by standard operation

5 Service plug
For connecting parameterising and service tools

Check power supply connection


2 Off and 3 On: Possible wiring error in power supply

Dimensions [mm]

Dimensional drawings 72 146 41

129
20

152 72
172

224
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 37
SRFA-5
Rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC 24...240V / DC 24...125V
• Control: Open/Close
• SRFA-5: Deenergised NC

Technical data
Electrical data Nominal voltage AC 24...240V, 50/60Hz / DC 24...125V
Nominal voltage range AC 19.2...264V / DC 21.6...137.5V
Power In operation 7W @ nominal torque
consumption At rest 3.5W
For wire sizing 18VA
Connection Cable 1m, 2 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Direction of rotation Spring return
– SRFA-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 75s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power level Motor ≤45dB(A)
Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class II totally insulated
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1.AA
Rated impulse voltage 4kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2kg

Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage possible!
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
V7.3 08.2015• Subject to modification

• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.

38 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator with emergency function for rotary valves, AC
24...240V / DC 24...125V, 20Nm SRFA-5

Product features
Mode of operation The actuator is equipped with a universal power module and can process supply voltages
from AC 24...240V plus DC 24...125V.
The actuator moves the valve to the operating position at the same time as tensioning the
return spring. The valve is turned back to the safety position by spring force if the supply
voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.

Electrical installation
Wiring diagram NT ~L AC 24...240V
– + DC 24...125V

1 2
Notes
• Caution: Power supply voltage possible! !
Cable colours:
• Parallel connection of other actuators possible. 1 = blue
Note the performance data. 2 = brown

Dimensions [mm]
Dimensional drawings

59
101

27

103

40
162
172
182
244
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 39
SRFA-S2-5
Rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC 24...240V / DC 24...125V
• Control: Open/Close
• Two integrated auxiliary switches
• SRFA-S2-5: Deenergised NC

Technical data
Electrical data Nominal voltage AC 24...240V, 50/60Hz / DC 24...125V
Nominal voltage range AC 19.2...264V / DC 21.6...137.5V
Power In operation 7W @ nominal torque
consumption At rest 3.5W
For wire sizing 18VA
Auxiliary switch 2 x SPDT, 1 x 10% / 1 x 11...90%
Connection Motor Cable 1m, 2 x 0.75mm²
Auxiliary switch Cable 1m, 6 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Direction of Spring return
rotation – SRFA-S2-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 75s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power Motor ≤45dB(A)
level Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class II totally insulated
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Low-voltage directive CE according to 2006/95/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1.AA.B
Rated impulse Actuator 4kV
voltage Auxiliary switch 2.5kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.2kg

Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• Caution: Power supply voltage possible!
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
V7.3 08.2015• Subject to modification

• The cable must not be removed from the device.


• The integrated switches of this actuator have to be connected either to Power supply volt-
age or safety extra low voltage. The combination Power supply voltage / safety extra low
voltage is not allowed.
• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.

40 UL marked actuators is optional, please contact your local Sales Representative for details.
Rotary actuator with emergency function for rotary valves,
AC 24...240V / DC 24...125V, 20Nm, with two auxiliary switches SRFA-S2-5

Product features
Mode of operation The actuator is equipped with a universal power module and can process supply voltages
from AC 24...240V plus DC 24...125V.
The actuator moves the valve to the operating position at the same time as tensioning the
return spring. The valve is turned back to the safety position by spring force if the supply
voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Flexible signalisation The actuator has one auxiliary switch with a fixed setting and one adjustable auxiliary
switch. They permit a 10% or 11...100% angle of rotation to be signalled.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.

Electrical installation
Wiring diagram N
T ~L
– +


230 V + 230 V
24 V + 24 V
230 V + 24 V
24 V + 230 V
Cable colours:
1 = blue
1 2 S1 S2 S3 S4 S5 S6 2 = brown
S1 = violet
Notes S2 = red
• Caution: Power supply voltage possible! ! S3 = white
• Parallel connection of other actuators possible. <A <B S4 = orange
A = 10% B = 11 ... 100% S5 = pink
Note the performance data. >A >B
S6 = grey

Dimensions [mm]
Dimensional drawings

59
101

27

103

40
162
172
182
244
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 41
SRF24A-SR-5
Modulating rotary actuator with emergency function for rotary valves
• Torque 20Nm
• Nominal voltage AC/DC 24V
• Control: modulating DC (0)2...10V
• Position feedback DC 2...10V
• SRF24A-SR-5: Deenergised NC

Technical data
Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption In operation 5.5W @ nominal torque
At rest 3.5W
For wire sizing 8.5VA
Connection Cable 1m, 4 x 0.75mm²
Parallel connection Yes (Note performance data for supply!)
Functional data Torque Motor Min. 20Nm @ nominal voltage
Spring return Min. 20Nm
Control Control signal Y DC (0)2…10V, input impedance 100k�
Operating range DC 2...10V
Position feedback (measuring voltage U) DC 2...10V, max. 0.5mA
Position accuracy ±5%
Direction of rotation Spring return
– SRF24A-SR-5 Deenergised NC, valve closed (A – AB = 0%)
Manual override With hand crank and interlocking switch
Angle of rotation Max. 90°
Running time Motor 90s / 90°
Spring return ≤20s @ –20...50°C / max. 60s @ –30°C
Sound power level Motor ≤45dB(A)
Spring return ≤62dB(A)
Position indication Mechanical
Safety Protection class III Extra low voltage / UL Class 2 Supply
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN 60730-
2-14
Mode of operation Type 1.AA
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensating
Maintenance Maintenance-free
Mechanical data Connection flange F05
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2kg

Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel.
All applicable legal or institutional installation regulations must be complied with.
V7.3 08.2015• Subject to modification

• The device may only be opened at the manufacturer's site. It does not contain any parts
that can be replaced or repaired by the user.
• The cable must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.

42 UL marked actuators is optional, please contact your local Sales Representative for details.
Modulating rotary actuator with emergency function for
rotary valves, AC/DC 24V, 20Nm SRF24A-SR-5

Product features
Mode of operation The actuator is controlled with a standard signal of DC (0)2...10V and moves the valve to
the operating position at the same time as tensioning the return spring. The valve is turned
back to the emergency position by spring force if the supply voltage is interrupted.
Simple direct mounting Straightforward direct mounting on the rotary valve with mounting flange. The mounting po-
sition in relation to the fitting can be selected in 90° steps.
Manual override Manual operation of the valve with the hand crank, locking in any position with the interlock-
ing switch. Unlocking is manual or automatic by applying the operating voltage.
Adjustable angle of rotation Adjustable angle of rotation with mechanical end stop.
High operational reliability The actuator is overload-proof, requires no limit switches and automatically stops when the
end stop is reached.
Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures
and closing pressures.

Electrical installation
T ~
Wiring diagram
– +

Y DC
DC (0)2...10V
0 … 10 V
U DC 2...10V
DC 2 … 10 V

1 2 3 5
Notes Cable colours:
• Connect via safety isolation transformer. ! 1 = black
• Parallel connection of other actuators possible. 2 = red
Note the performance data. 3 = white
5 = orange

Direction of rotation NO NC
L R

Reversing switch

Y=0 Y=0
A – AB = 100%

Dimensions [mm]
Dimensional drawings
59
101

27

103

40
162
V7.3 08.2015• Subject to modification

172
182
244

UL marked actuators is optional, please contact your local Sales Representative for details. 43
GRK24A-5 / -7
SuperCap rotary actuator with emergency setting function and
extended functionalities for rotary valves with mounting flange
• Torque 40Nm
• Nominal voltage AC/DC 24V
• Control: Open/Close
• Design lifeSuperCaps 15 years

Technical data
Electrical data Nominal voltage AC 24V, 50/60 Hz / DC 24V
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption In operation 11W @ nominal torque
At rest 3W
For wire sizing 21VA (lmax 20A @ 5ms)
Connection Cable 1m, 2 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque min. 40Nm @ nominal voltage
Emergency setting position (POP) NC / NO
Position accuracy ±5%
Manual override Gearing latch disengaged with push button
Running time Motor 150s / 90°
Emergency setting 35s @ 0...50°C
function
Sound power level Motor ≤52dB(A) @ 150s
Emergency setting ≤61dB(A)
function
Position indication Mechanical
Safety Protection class III Safety extra-low voltage
UL Class 2 Supply
Degree of protection IP54
NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification Certified to IEC/EN 60730-1 and IEC/EN
60730-2-14
Principle of operation Type 1.AA
Rated impulse voltage 0.8kV
Control pollution degree 3
Ambient temperature –30...+50°C
Non-operating temperature –40...+80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GRK24A-5 F05
GRK24A-7 F07
Dimensions / Weight Dimensions See «Dimensions»
Weight Approx. 2.8kg

Safety notes
• The actuator has been designed for use in stationary heating, ventilation and air condi-
! tioning systems and is not allowed to be used outside the specified field of application,
especially in aircraft or in any other airborne means of transport.
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during installation.
• The switch for changing the direction of rotation may only be operated by authorised
personnel. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer's site. It does not contain any parts
V7.3 08.2015• Subject to modification

that can be replaced or repaired by the user.


• The cable must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be dis-
posed of as household refuse. All locally valid regulations and requirements must be ob-
served.

44 UL marked actuators is optional, please contact your local Sales Representative for details.
GRK24A-5 / -7

Product features
Mode of operation The actuator moves the valve to the desired operating position at the same time as the
integrated capacitors are loaded. Interrupting the supply voltage causes the valve to be
rotated back into the emergency setting position by means of stored electrical energy.
Pre-charging time (start up) The capacitor actuators require a pre-charging time. This time is used for charging the
capacitors up to a usable voltage level. This ensures that, in the event of an electricity in-
terruption, the actuator can be moved at any time from its current position into the preset
emergency setting position (POP).
The duration of the pre-charging time depends mainly on how long the power was inter-
rupted.
Typical pre-charging times 30 30

25 25

Pre-charging time [s]


20 20

15 15
Duration of voltage interruption
[Days]
10 10
0 1 2 7 ≥10
Pre-charging
6 9 11 16 20
time [s] 5 5

0 0
0 2 4 6 8 10 12
Duration of voltage interruption [Days]

Delivery condition (capacitors) The actuator is completely discharged after delivery from the factory, which is why the
actuator requires approximately 20s pre-charging time before initial commissioning in
order to bring the capacitors up to the required voltage level.
Simple direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Manual override Manual override with push button possible (the gear is disengaged for as long as the
button remains pressed down).
High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when
the end stop is reached.
Direction of rotation switch When actuated, the direction of rotation switch changes the running direction in normal
operation.
The direction of rotation switch has no influence on the emergency setting position
(POP) which has been set.
In case of changing the emergency position from NC to NO, it is mandatory necessary to
also change the direction of rotation switch.
Emergency setting position (POP) The «Emergency setting position» rotary button can be used to adjust the desired emer-
rotary button gency setting position (POP). The POP range is in reference to the maximum angle of
rotation of the actuator.
In the event of an voltage interruption, the actuator will move into the selected emer-
gency setting position, taking into account the bridging time (PF) of 2s which was set
ex-works.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
V7.3 08.2015• Subject to modification

Feedback potentiometer 500 Ohm, add-on P500A


Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A

UL marked actuators is optional, please contact your local Sales Representative for details. 45
GRK24A-5 / -7

Wiring diagram
~
Wiring diagram
T
– +

Notes NC NO
• Connection via safety isolation transformer. ! A – AB = 0% A – AB = 100%
1 2
• Parallel connection of other actuators possible. POP POP
Note the performance data. Cable colours:
NO NC NO NC
1 = black
2 = red

Operating controls and indicators


Cover, POP button

POP button

Scale for manual adjustment


POP

NO NC

Status
(no function)

Disengagement button

LED display
Meaning / function
green
Illuminated Operation OK / without fault
Blinking POP function active
Off – Not in operation
– Pre-charging time SuperCap
– Fault SuperCap

Setting the POP Power off position

A – AB
100 %
NO NC

POP

NO NC

Status A – AB
0%
NO NC

Dimensions [mm]
Dimensional drawings 44 174
102

8
∅6
V7.3 08.2015• Subject to modification
45°

124
99
50

69 214

46 UL marked actuators is optional, please contact your local Sales Representative for details.
GRK24A-MF-5 / -7
Modulating SuperCap rotary actuator with emergency control
function and extended functionalities for rotary valves
• Nominal torque 40Nm
• Nominal voltage AC/DC 24V
• Control Modulating DC (0)2...10V
• Position feedback DC 2...10V
• Design life SuperCaps: 15 years

Technical data
Electrical data Nominal voltage AC/DC 24V
Nominal voltage frequency 50/60Hz
Nominal voltage range AC 19.2...28.8V / DC 21.6...28.8V
Power consumption in operation 11W
Power consumption in rest position 3W
Power consumption for wire sizing 21VA
Power consumption for wire sizing note Imax 20A @ 5ms
Connection supply / control Cable 1m, 4 x 0.75mm²
Parallel operation Yes (note the performance data)
Functional data Torque motor Min. 40Nm
Positioning signal Y DC 0...10V
Positioning signal Y note Input impedance 100kΩ
Operating range Y DC 2...10V
Operating range Y variable Start point DC 0.5...30V
End point DC 2.5...32V
Position feedback U DC 2...10V
Position feedback U note Max. 0.5mA
Position feedback U variable Start point DC 0.5...8V
End point DC 2.5...10V
Setting emergency position (POP) NC / NO or adjustable 0...100% (POP rotary
button)
Bridging time (PF) variable 1...10s
Position accuracy ±5%
Manual override Gear disengagement with push-button
Running time motor 150s / 90°
Running time emergency control position 35s / 90°
Adaption setting range manual (automatic on first power-up)
Sound power level motor 52dB(A)
Sound power level emergency control 61dB(A)
position
Position indication Mechanical
Safety Protection class IEC/EN III Safety extra-low voltage
Protection class UL UL Class 2 Supply
Degree of protection IEC/EN IP54
Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2
EMC CE according to 2004/108/EC
Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14
Mode of operation Type 1.AA
Rated impulse voltage supply / control 0.8kV
Control pollution degree 3
Ambient temperature -30...50°C
Non-operating temperature -40...80°C
Ambient humidity 95% r.h., non-condensing
Maintenance Maintenance-free
Mechanical data Connection flange GRK24A-MF-5 F05
GRK24A-MF-7 F07
V7.3 08.2015• Subject to modification

Weight Weight Approx. 2.9kg


Terms Abbreviations POP = Power off position / emergency setting
position
CPO = Controlled power off / controlled
emergency control function
PF = Power fail delay time / bridging time

UL marked actuators is optional, please contact your local Sales Representative for details. 47
GRK24A-MF-5 / -7 SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm

Safety notes
• This device has been designed for use in stationary heating, ventilation and air

! conditioning systems and is not allowed to be used outside the specified field of
application, especially in aircraft or in any other airborne means of transport.
• Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
• The switch for changing the direction of rotation may only be operated by authorised
specialists. The direction of rotation must not in particular be reversed in a frost protection
circuit.
• The device may only be opened at the manufacturer‘s site. It does not contain any parts
that can be replaced or repaired by the user.
• Cables must not be removed from the device.
• The device contains electrical and electronic components and is not allowed to be
disposed of as household refuse. All locally valid regulations and requirements must be
observed.

Product features
Mode of operation The actuator moves the valve to the desired operating position at the same time as the
integrated capacitors are loaded.
Interrupting the supply voltage causes the valve to be moved to the selected emergency
setting position (POP) by means of stored electrical energy.
Pre-charging time (start up) The capacitor actuators require a pre-charging time. This time is used for charging the
capacitors up to a usable voltage level. This ensures that, in the event of an electricity
interruption, the actuator can move at any time from its current position into the preset
emergency setting position (POP).
The duration of the pre-charging time depends mainly on following factors:
– Duration of the electricity interruption
– PF delay time (bridging time)

Typical pre-charging time


30 30
[s] PF [s] [s]
10 s
25 25

5s
20 2s 20
0s

15 15

10 10

5 5

[d] = Electricity interruption in days


[s] = Pre-charging time in seconds 0
0 2 4 6 8 10 [d] 12
0

PF[s] = Bridging time


PF [s] [d]
Calculation example: Given an electricity 0 1 2 7 ≥10
interruption of 3 days and a bridging time 0 5 8 10 15 19
(PF) set at 5s, the actuator requires a pre- 2 6 9 11 16 20
charging time of 14s after the electricity 5 8 11 13 18 22
10 12 15 17 22 26
has been reconnected (see graphic). [s]

Delivery condition (capacitors) The actuator is completely discharged after delivery from the factory, which is why the
actuator requires approximately 20s pre-charging time before initial commissioning in
order to bring the capacitors up to the required voltage level.
Parameterisable actuators The factory settings cover the most common applications. Input and output signals and
other parameters can be altered with the PC-Tool MFT-P or with the Service tool ZTH AP.
Simple Direct mounting Simple direct mounting on the rotary valve with mounting flange. The mounting position
in relation to the fitting can be selected in 90° steps.
Manual override Manual control with push-button possible - temporary. The gear is disengaged and the
actuator decoupled for as long as the button is pressed.
High functional reliability The actuator is overload protected, requires no limit switches and automatically stops
when the end stop is reached.
V7.3 08.2015• Subject to modification

Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.
Combination valve/actuator For valves with the following mechanical specifications in accordance with ISO 5211 F05:
- Square stem head SW = 14mm for form fit coupling of the rotary actuator.
- Hole circle d = 50mm
For valves with the following mechanical specifications in accordance with ISO 5211 F07:
- Square stem head SW = 17mm for form fit coupling of the rotary actuator.
- Hole circle d = 70mm

48 UL marked actuators is optional, please contact your local Sales Representative for details.
SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm GRK24A-MF-5 / -7

Product features
Home position The first time the supply voltage is switched on, i.e. at the time of commissioning, the
actuator carries out an adaption, which is when the operating range and position feedback
adjust themselves to the mechanical setting range.
The actuator then moves into the position defined by the positioning signal.
Factory setting: Y2 (counter-clockwise rotation).
Direction of rotation switch When actuated, the direction of rotation switch changes the running direction in normal
operation. The direction of rotation switch has no influence on the emergency setting
position (POP) which has been set.
Adaption and synchronisation An adaption can be triggered manually by pressing the „Adaption“ button or with the PC-
Tool. Both mechanical end stops are detected during the adaption (entire setting range).
Automatic synchronisation after pressing the gearbox disengagement button is configured.
The synchronisation is in the home position (0%).
The actuator then moves into the position defined by the positioning signal.
A range of settings can be adapted using the PC-Tool (see MFT-P documentation)
Rotary knob emergency setting The «Emergency setting position» rotary knob can be used to adjust the desired emergency
position setting position (POP). In the event of an electricity interruption, the actuator will move into
the selected emergency setting position, taking into account the bridging time (PF) of 2s
which was set ex-works.
Settings: The rotary knob must be set to the «Tool» position for retroactive settings of the
emergency setting position with the BELIMO service tool MFT-P. Once the rotary knob is set
back to the range 0…100%, the manually set value will have positioning authority
Bridging time (PF) Electricity interruptions can be bridged up to a maximum of 10s.
In the event of an electricity interruption, the actuator will remain stationary in accordance
with the set bridging time. If the electricity interruption is greater than the set bridging time,
then the actuator will move into the selected emergency setting position (POP).
The bridging time set ex-works is 2s. This can be modified on site in operation with the use
of the BELIMO service tool MFT-P.
Settings: The rotary knob must not be set to the «Tool» position!
Only the values need to be entered for retroactive adjustments of the bridging time with the
BELIMO service tool MFT-P.

Accessories
Description Type
Electrical accessories Auxiliary switch, add-on, 1 x SPDT S1A
Auxiliary switch, add-on, 2 x SPDT S2A
Feedback potentiometer 140 Ohm, add-on P140A
Feedback potentiometer 200 Ohm, add-on P200A
Feedback potentiometer 500 Ohm, add-on P500A
Feedback potentiometer 1 kOhm, add-on P1000A
Feedback potentiometer 2.8 kOhm, add-on P2800A
Feedback potentiometer 5 kOhm, add-on P5000A
Feedback potentiometer 10 kOhm, add-on P10000A
Description Type
Service Tools Service Tool, for MF/MP/Modbus/LonWorks actuators and VAV- ZTH AP
Controller
Belimo PC-Tool, software for adjustments and diagnostics MFT-P

Electrical installation

Notes • Connection via safety isolating transformer.


! • Parallel connection of other actuators possible. Observe the performance data.
• Direction of rotation switch Factory setting: Direction of rotation Y2.

Wiring diagrams

AC/DC 24V, modulating


T ~
– +
Y DC (0)2…10 V
U DC 2…10 V
V7.3 08.2015• Subject to modification

1 2 3 5 Cable colours:
1 = black
2 = red
3 = white
5 = orange

UL marked actuators is optional, please contact your local Sales Representative for details. 49
GRK24A-MF-5 / -7 SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm

Functions
Functions with basic values (conventional mode)

Override control with AC 24V with relay contacts Override control with AC 24V with rotary switch
~ ~

ZS 50%
T T

(DC 0...10 V)
Y
100%
0%
c Y (DC 0...10 V)
a b

a b c e.g. 1N 4007
0%
1 2 3 5 e.g. 1N 4007 1 2 3 5
ZS 50%

100%
Y U Y U
Y

Control Open/Close Control 3-point


T ~ T ~
– +
U U
a b

e.g. 1N 4007
Y1 Y1

a b Y2 Y2
1 2 3 5 1 2 3 5

Y U Y U

Operating controls and indicators

V7.3 08.2015• Subject to modification

50 UL marked actuators is optional, please contact your local Sales Representative for details.
SuperCap rotary actuator, Modulating, AC/DC 24V, 40Nm GRK24A-MF-5 / -7

Operating controls and indicators (continued)

Dimensions [mm]
Dimensional drawings 44 174

102
124
99

69 214
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 51
SY.. Large Torque Multi-function Actuators

• General Large Torque Actuators DN50...600 Butterfly Valves


for operation of: 35...3500Nm
• Torque: SY...24-3-T, SY...230-3-T
• Open/Close or 3-point control: SY1U24-SR-T, SY1U230-SR-T
• Modulating control: SY...U24-MF-T, SY...U230-MF-T

Technical data
Nominal voltage AC 24V ± 10%
SY...-3-T, SY...-SR-T AC 230V ± 10%
Nominal voltage range AC 21.6...26.4V
SY...-3-T, SY...-SR-T 207...253V
Connecting cable ½” cable connector, screw terminals
Motor protection H class insulation (SY1), F class insulation (SY2...12)
Gear train High alloy steel gear sets
Control signal Y DC (0)2...10V
Sensitivity 200mV
Position feedback signal U DC (0)2...10V
Angle of rotation Electrically limited to 90°, Max. 95° for manual operation
Position indicator Top mounted domed indication
Auxiliary switches 2xSPDT 3A, AC 230V(SY1); 2xSPDT 5A, AC 230V(SY2...12)
Ambient temp. -20...+60°C
Humidity 5...95% RH, non-condensing
Degree of protection IP67
Housing material Die Cast Aluminium Alloy
EMC CE according to 2004/108/EC
Low voltage directive CE according to 2006/95/EC
* MP-T models available on request

Motor power Running time Running current


Nominal
Model Weight Mounting
Torque AC AC 230V AC AC Manual override
No. AC 24V AC 230V (kg) flange
(Nm) 24V 24V 230V
50Hz 60Hz
SY1.. 35 10W 10W 15s 13s 12s 0.6A 0.3A by 8mm Wrench 2 F05
SY2.. 90 70W 40W 15s 17s 15s 3.0A 0.5A Handwheel 11 F07
SY3.. 150 70W 40W 22s 26s 22s 3.0A 0.5A Handwheel 11 F07
SY4.. 400 180W 120W 16s 18s 16s 6.0A 0.6A Handwheel 22 F10
SY5.. 500 180W 120W 22s 25s 22s 6.5A 0.7A Handwheel 22 F10
SY6.. 650 / 120W / 31s 28s / 0.8A Handwheel 22 F10
SY7.. 1000 / 180W / 55s 46s / 1.6A Handwheel 36 F14
SY8.. 1500 / 220W / 55s 46s / 2.0A Handwheel 36 F14
SY9.. 2000 / 180W / 70s 58s / 1.6A Handwheel 56 F16
SY10.. 2500 / 220W / 70s 58s / 2.0A Handwheel 56 F16
SY11.. 3000 / 250W / 70s 58s / 1.6A Handwheel 56 F16
SY12.. 3500 / 300W / 70s 58s / 2.2A Handwheel 56 F16

Product Feature
Electrical connections All actuator control elements are wired to a terminal strip under the main cover. Remove the
cover and insert the cables through the cable connector in order to reach the terminal strip.
V7.3 08.2015• Subject to modification

The connectors should be made according to the diagram. Before beginning this procedure,
make sure that the power supply voltage is in accordance with the actuator’s name plate.
After the terminal connections have been made, move the actuator manually to the half-open
position and make a preliminary check of the wiring.
Overload protection If the real running torque exceeds the nominal torque, the overload protection will be
functioned to prevent the motor overload.
Manual operation The manual operation is available by turning a handwheel of actuators (SY2...12) and using
a 8mm wrench for SY1.
52 UL marked actuators is optional, please contact your local Sales Representative for details.
SY.. Large Torque Multi-function Actuators

Ordering sample
SY4 U230 -MF -T

With terminal only eg.Modulating control


“-MF/SR”: Modulating control SY2U230-MF-T
“-3”: Open/Close or 3-point control Open/Close, 3-point control
“U24”: 24V nominal voltage (modulating) SY2-230-3-T
“U230”: 230V nominal voltage (modulating)
“-24”: 24V nominal voltage (Open/Close, 3-point)
“-230”: 230V nominal voltage (Open/Close, 3-point)
Model number

Wiring diagrams
SY..-24-3-T Open/Close or 3-point control Terminal
Auxiliary switch
AC 24V A B C E F
T ~
#1 Power supply Com/Neutral

#3 Power supply Hot line for Open


Notes: S1 100%
• Connection via safety isolating transformer. ! #4 Power supply Hot line for Close
S2 0%

• Relays are needed in parallel connection of #5 Connect to Com/Neutral for SY1-24-3-T


several actuators
1 3 4 5 6 7 fully open indication

#6 Connect to Com/Neutral for A B C D E F


• “L” cannot be connected to terminal #3 and fully close indication
#4 simultaneously.
#7 Heater S1 100% S2 0%
• 30% duty cycle. H
SY(2...4)-24-3-T

SY..-230-3-T Open/Close or 3-point control Terminal


Auxiliary switch
! #1 Power supply Com/Neutral
AC 230V
T ~
A BC E F
WARNING! Leakage current is #3 Power supply Hot line for Open
possible (<3.5mA)! S1 100%
#4 Power supply Hot line for Close
Connect the earth first before
S2 0%
#5 Connect to Com/Neutral for
applying any supply voltage! SY1-230-3-T
fully open indication
Disconnect the supply voltage 1 3 4 5 6 7
#6 Connect to Com/Neutral for
before the earth!
fully close indication A B C D E F
#7 Heater
Notes: S1 100% S2 0%
H
• Caution: Power supply voltage! ! SY(2...12)-230-3-T
• Relays are needed in parallel connection of
several actuators
• “L” cannot be connected to terminal #3 and
#4 simultaneously.
• 30% duty cycle.

SY1U24-SR-T Modulating control Terminal

~ T
AC 24V
#4 Power supply Com/Neutral
Auxiliary switch
Notes: #5 Power supply Hot line
– + – + A BC E F
• Connection via safety isolating transformer. ! #6 Control signal -

• Power supply Com/Neutral and control #7 Control signal + S1 100%


signal “-” wiring to a common is prohibited. #8 For actuator internal use S2 0%
4 5 6 7 8 9 10 11 12
• The control signal has to be separated from #9 For actuator internal use
the others and shielded.
• 75% duty cycle. H #10 For actuator internal use

5K #11 Feedback signal -

#12 Feedback signal +


V7.3 08.2015• Subject to modification

53
SY.. Large Torque Multi-function Actuators

Wiring diagrams (continued)

SY1U230-SR-T Modulating control Terminal

!
#4 Power supply Com/Neutral
WARNING! Leakage current is ~ T
AC 230V #5 Power supply Hot line
possible (<3.5mA)!
Connect the earth first before #6 Control signal -
Auxiliary switch
applying any supply voltage! #7 Control signal +
Disconnect the supply voltage – + – + A BC E F
#8 For actuator internal use
before the earth!
S1 100%
#9 For actuator internal use

Notes: 4 5 6 7 8 9 10 11 12 #10 For actuator internal use


S2 0%

• Caution: Power supply voltage! ! #11 Feedback signal -

• Power supply Com/Neutral and control H #12 Feedback signal +


signal “-” wiring to a common is prohibited. 5K
• The control signal has to be separated from
the others and shielded.
• 75% duty cycle.

SY..U24-MF-T Modulating control Terminal

AC 24V ┴ Power supply Com/Neutral

~ Power supply Hot line Auxiliary switch


~ T
Notes: A B C D E F
Y Control signal +
• Connection via safety isolating transformer. ! Y
T
1 U5
T
2 C1 C2 ┴1 Control signal - S1 100% S2 0%
• Power supply Com/Neutral and control U5 Feedback signal +
signal “-” wiring to a common is prohibited. SY(2...4)U24-MF-T
┴2 Feedback signal -
• The control signal has to be separated from + – + –
the others and shielded. C1
leave unconnected
• 75% duty cycle. C2

SY..U230-MF-T Modulating control Terminal


! ┴ Power supply Com/Neutral

WARNING! Leakage current is ~ Power supply Hot line


possible (<3.5mA)! AC 230V
Connect the earth first before
applying any supply voltage! Y Control signal + Auxiliary switch
Disconnect the supply voltage
before the earth!
N L ┴1 Control signal -

U5 Feedback signal +
A B C D E F
T T
Notes: Y 1 U5 2 C1 C2 ┴2 Feedback signal -
S1 100% S2 0%

• Caution: Power supply voltage! ! C1


leave unconnected
SY(2...12)U230-MF-T
• Power supply Com/Neutral and control + – + – C2
signal “-” wiring to a common is prohibited.
• The control signal has to be separated from
the others and shielded.
• 75% duty cycle.

SY..U24-MP-T Modulating control Terminal

AC 24V ┴ Power supply Com/Neutral

Notes: ~ Power supply Hot line Auxiliary switch


• Connection via safety isolating transformer. ! ~ T
• Power supply Com/Neutral and control Y Sensor signal + A B C D E F
signal “-” wiring to a common is prohibited. T T
Y 1 U5 2 C1 C2 ┴1 Sensor signal -
• The control signal has to be separated from S1 100% S2 0%
U5 MP-Bus signal +
the others and shielded. SY(2...4)U24-MP-T
• 75% duty cycle. + – + – ┴2 MP-Bus signal -

C1
V7.3 08.2015• Subject to modification

leave unconnected
C2

54
SY.. Large Torque Multi-function Actuators

Dimensions [mm]

øB

D D

A 1)

C C
øB øB

E
A A
C N-S F
F
øD
J E E
G
G
øH øH

IxM
øH N-S
IxM N-S
G IxM

SY1.. SY2/3.. SY4..6..

C C

D D

N-S N-S

øB
øB

A
A F

E E
J J IxM
G
øH øK

øH

øK IxM G

SY7/8.. SY9..12.. 1) For SY1U24(230)-SR-T, A is 183.


2) For SY2(3)-230-3-T, A is 255.

Dim
A B C D E ΦF G H I J K M N S Flange type
Model No
SY1.. 150 1) 106 8 19 15 - 14 50 4 45° - M6 2 1/2 PS F05
SY2/3.. 255 2) 181 326 208 30 123 17/22 70 4 - 90 M8 2 1/2 PS F07
V7.3 08.2015• Subject to modification

SY4..6.. 317 217 394 294 40 194 22/35 102 4 - 125 M10 2 1/2 PS F10
SY7/8.. 406 217 347 336 45 295 36 140 4 45° 180 M16 2 1/2 PS F14
SY9...12.. 564 256 455 392 57 395 36 165 4 45° 221 M20 2 1/2 PS F16

55
SY.. Large Torque Multi-function Actuators

Circuit board set up

SY1U24-SR-T SY1U230-SR-T
Disconnect power supply •DIP switches setting
! before changing the follow-
ing settings.
Factory setting
8 7 6 5 4 3 2 1 Off
The words in bold are
default settings. On (Only available for SY1U24/230-SR-T)
When you need to adjust the signal of modulating board,
please adjust the VR1 and VR2:
S6 - Direction of S7 and S8 - Actuator
S1, S2 - for S3, S4, S5 - for
Travel in response response to the • VR2 adjusts 4mA, 2V, 1V (Fully-closed)
Input signal Output signal
to the control control signal failure • VR1 adjusts 20mA, 10V, 5V (Fully-open)
Input Output When sig-
S1 S2 S3 S4 S5 Symbol S6 S7 S8
signal signal nal fails Please turn the VR2 to the end by clockwise direction and
(0)2...10V Off On (0)2...10V On Off On 90
°
Fully closed Off On input 4mA to modulating board. Then please slightly turn
Off
Y the VR2 by counter-clockwise direction about 3...6 times
4...20mA On Off Fully open On Off
4...20mA Off On Off 90° until the RED light keeps ON.
On
1...5V Off Off Y Stop On On

•SW1 sensitive switch Please turn the VR1 to the end by counter clockwise direc-
Position “0”: Lowest sensitive, 0...90° divided into 17 steps.
tion and input 20mA to modulating board. Then please
Position “1”: Highest sensitive, 0...90° divided into 80 steps.
Prior to switch-on, make sure the input signal and voltage wiring are in slightly turn the VR1 by clockwise direction about 3...6
accordance with the actuator name plate and Dip-switch setting. times until the GREEN light keeps ON.

Service Jack
Connect to PC-Tool

Service Jack
Connect to PC-Tool

SY(2...4)U24-MF/MP-T SY(2...12)U230-MF-T Direction switch


Y2 standard
Factory setting

Position feedback potentiometer

For modulating actuators, the potentiometer is a standard part.


RA
25 Potentiometer points 1, 2, 3 are wired to terminal blocks 10, 9, 8.
Y

When the actuator is closed: 8, 9 5kΩ


9, 10 0kΩ
When the actuator is open: 8, 9 0kΩ
V7.3 08.2015• Subject to modification

9, 10 5kΩ

Potentiometer

56
SY.. Large Torque Multi-function Actuators

Travel cams TC..

Only authorised and trained persons are


shaft
allowed to change the settings.
shaft
TC4
• TC1-for open position of limit switch
(factory setting 90°). LS4 TC4
LS3 TC3 LS4
• TC2-for closed position of limit switch LS2 LS3 TC3
(factory setting 0°). LS1 TC2
LS2
LS1 TC2
• TC3-for open position of auxiliary switch TC1
(factory setting 87°).
TC1
SY1-..actuator SY2...12-..actuator
• TC4-for closed position of auxiliary switch
(factory setting 3°).
The cams for adjusting the limit and auxiliary switches are accessible if the cover is removed.
The LS2/LS1 limit switches interrupt the power supply to the motor and are controlled by means
of the TC.. cams which rotate with the shaft. The LS4/LS3 auxiliary switches can optionally be
connected for signalisation purposes. The actuator closes the valve when the shaft turns clock-
wise (CW) and opens the valve when the shaft turns counter clockwise (CCW).

Relationship of auxiliary switches, limiting switches and limits of manual rotation angle

• A stop screw for OPEN limiting


• B stop screw for CLOSED limiting
• C stop screw connection for manual operation
The limits of manual operation is set at -2°...92° in the factory. The override handwheel turns the
planetary gear by means of a worm wheel. The gear is stopped mechanically by the two stop
screws A and B.

Angle Range 1: Two auxiliary switches LS3 and LS4 are set at 3°...87° angle in the factory
Angle Range 2: The two limit switches LS2 and LS1 are set at 0°...90° angle in the factory
Angle Range 3: Two stop screws A and B are set at -2°...92° angle in the factory

Fully Open/Closed position setting


Fully Closed position (0%) setting 1) Power on. The actuator will drive CW to closed position.
2) Check whether disc of valve at fully closed position.
3) Adjust travel cams TC2 and stop screws for closed limiting (see “Adjusting travel cams
and stop screws”)
Fully Open position (100%) setting 1) Power on. The actuator will drive CCW to open position.
2) Check whether disc of valve is at fully open position.
3) Adjust travel cams TC1 and stop screws for open limiting (see “Adjusting travel cams
and stop screws”)
V7.3 08.2015• Subject to modification

57
SY.. Large Torque Multi-function Actuators

Adjusting the TC and stop screws

1. Loosen the corresponding stop screw; Open


2. Loosen the travel cam to be re-adjusted with a 2.5mm hexagonal key;
3. Turn the travel cam clockwise or counter clockwise with the hexagonal key as shown in the right

( C CW)

W)
diagram and initially tighten the cam;

TC1/TC3 (C
Current position
4. Check the full rotation of limit switch with power on;

TC1/TC3
Required position
5. Tighten the travel cam after successful re-adjustment, otherwise repeat to do point 3 and 4 until
the travel cam is successfully re-adjusted.
6. When the motor stops at fully closed or open position, tighten the corresponding stop screw ( CCW)
TC 2/TC4
until it touches the gearbox, turn the stop screw cycle back and lock by a hexagonal key and a Close
wrench (1 turn of the stop screw corresponding to 2° angle of rotation around). TC2/TC4 (C
W)
• The LS2/LS1 switches must always switch off the motor before the effect of stop screws.
• Perform an adaption after changing the position of the travel cam
Adaption button

Installation guidelines

Cautions of installation • Check power supply before wiring.


• Replace housing cover immediately after making adjustments and make sure seal is se-
cure. If water or dust is present, thoroughly dry and clean before replacing housing.
• The motor cannot be reversed and the actuator cannot be installed upside down.
• Be sure to keep it away from gas; do not use in explosive and chemical district.
• Power off before maintenance purpose.
• The Open/Close frequency of the electric actuator is restricted according to the duty cycle
to avoid overheating.
Maintenance All actuators are lubricated with anti-high temperature lubricant for a long life and therefore
require no special maintenance. The condition of the valve stem and its nut must be checked
periodically to make sure they are clean and well lubricated. We recommend that a program
of periodic maintenance should be drawn up for actuators that are operated infrequently.
Storage The actuator includes electrical equipment as well as grease lubricated gear stages. In spite
of the weather proof enclosure, oxidation, jamming and other alterations are possible if the
actuator is not correctly stored. The actuator should be stored under a shelter in a clean,
dry place and protected from frequent changes in temperature. Avoid placing the actuators
directly on the floor. The actuators are equipped with heat resistance, but it’s recommended
to connect the actuators to the power supply, especially if storage area is humid. Check that
the temporary sealing plug of the cable entries are well in place. Make sure that the covers
and boxes are well closed to ensure weather proof sealing.

FAQ

Conditions Possibilities Solutions


Motor overheat Voltage abnormal Check by multimeter
High working frequency Limit the working frequency
Motor spindle is stuck or valve is too tight to move Replace the stuck assemblies or the valve.
The gear box stuck by stop screw Check and correct travel cam for evidence of loosening; inspect
the stop screw setting by operating the handwheel manually.

No operation Power supply or voltage abnormal Check the power supply voltage with the identification plate.
Fuse blown Check and replace the fuse as required (except for HW-CBPCB)
Tripping of motor thermal protective device Check if the motor is hot.The actuator will be available again
after the motor has cooled down. Solve the motor overheat
problem.
Running motor stops Power supply has short circuit Check wiring
External object stuck in the pipe Take off the valve for cleaning
Not fully opening/closing The fixing screw for travel cam is loose Re-adjust and tighten the travel cam
The actuator is continually The sensitivity setting is incorrect Adjust the sensitivity switch SW1 to increase the number (only
hunting for SY1..).
Occasional fail in motor Power input of ”open” and ”close” simultaneously Check if the external control switch is normal; relays are needed
switched on or off in parallel connection of several actuators
V7.3 08.2015• Subject to modification

58
D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo

2-way Butterfly Valves flanged


DN50...500

For Open/Close or modulating control of cold and hot water.


Applications
Typical applications include chiller isolation, cooling tower isolation,
change-over systems, large air handling coil control, bypass and
process control.

Technical data
Flow medium Nylon coated disc Cold and hot water
SS304 disc Cold and hot water, Max. 50% glycol
Temperature of medium Nylon coated disc 0...+95°C
SS304 disc -20...+100°C
Nominal pressure 1600kPa (PN16)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...500)
PN16 for lug (DN50...500)
Max. Close-off pressure 1200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50...500)
Disc Nylon-coated ductile cast iron disc/ Stainless steel 304 disc
Seat EPDM
Shaft Stainless steel 416
Bushing RPTFE

Ordering sample

D6 125 MH D6 125 MW

MH: manually operated by handle MW: manually operated by worm gear

Size: DN125 Size: DN125

Butterfly Valve: D6 series Butterfly Valve: D6.. series

Mode of operation
The Butterfly Valve is operated by a handle or a worm gear. Select the actuator according to
the required Close-off pressure and HVAC condition of installation. The discs are controlled
by manual operators.
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 59
Dimensions of D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo

D650...150..MH

Dimensions of PN10/16 Table E, wafer connection handle Butterfly Valves [mm]

PN10 PN16 Table E NC SS


Type Size L C S H1 H2 H3 A BFV BFV
øD n-ød øD n-ød øD n-ød (kg) (kg)
D650..MH DN50 43 33 118 65 130 64 170 125 4-18 125 4-18 114 4-18 2.3 2.3
D665..MH DN65 46 48 135 71 143 64 170 145 4-18 145 4-18 127 4-18 2.7 2.7
D680..MH DN80 46 66 149 92 155 64 170 160 8-18 160 8-18 146 4-18 3.1 3.0
D6100..MH DN100 46 66 149 92 155 64 170 180 8-18 180 8-18 178 8-18 4.8 4.6
D6125..MH DN125 56 115 176 118 190 75 260 210 8-18 210 8-18 210 8-18 7.2 6.8
D6150..MH DN150 56 142 204 132 210 75 260 240 8-22 240 8-22 235 8-22 8.4 8.3

D650...250..MW D6300...450..MW D6500..MW

Dimensions of PN10/16 Table E, wafer connection worm gear Butterfly Valves [mm]

PN10 PN16 Table E NC SS


Type Size L C S H1 H2 H3 A øF BFV BFV
øD n-ød øD n-ød øD n-ød (kg) (kg)
D650..MW DN50 43 33 118 65 130 50 128 140 125 4-18 125 4-18 114 4-18 3.4 3.4
D665..MW DN65 46 48 135 71 143 50 128 140 145 4-18 145 4-18 127 4-18 3.8 3.8
D680..MW DN80 46 66 149 92 155 50 128 140 160 8-18 160 8-18 146 4-18 4.2 4.1
D6100..MW DN100 46 66 149 92 155 50 128 140 180 8-18 180 8-18 178 8-18 5.7 5.5
D6125..MW DN125 56 115 176 118 190 50 128 140 210 8-18 210 8-18 210 8-18 8.0 7.6
D6150..MW DN150 56 142 204 132 210 50 128 140 240 8-22 240 8-22 235 8-22 9.1 9.0
D6200..MW DN200 60 194 260 167 243 60 180 300 295 8-22 295 12-22 292 8-22 16.5 15.2
D6250..MW DN250 68 245 316 198 282 60 180 300 350 12-22 355 12-26 356 12-22 24.1 22.9
D6300..MW DN300 78 294 372 231 310 81 213 300 400 12-22 410 12-26 406 12-26 38.0 40.1
V7.3 08.2015• Subject to modification

D6350..MW DN350 78 328 422 256 345 81 213 300 - - 470 16-26 - - 51.6 50.2
D6400..MW DN400 102 374 473 294 377 120 251 400 - - 525 16-30 - - 84.4 86.6
D6450..MW DN450 114 425 526 337 422 120 251 400 - - 585 20-30 - - 100.8 102.9
D6500..MW DN500 127 472 582 375 466 124 254 300 - - 650 20-33 - - 134.5 131.4

60 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..MH/MW Series Butterfly Valves
Trade Selection by Belimo

D650...150L..MH

Dimensions of PN16 lug connection handle Butterfly Valves [mm]

PN16 NC SS
Type Size L C S H1 H2 H3 A BFV BFV
øD n-M (kg) (kg)
D650L..MH DN50 43 33 115 65 130 64 170 125 4-M16 2.8 2.8
D665L..MH DN65 46 48 132 71 143 64 170 145 4-M16 3.4 3.4
D680L..MH DN80 46 66 175 92 155 64 170 160 8-M16 4.5 4.4
D6100L..MH DN100 46 66 175 92 155 64 200 180 8-M16 6.4 6.2
D6125L..MH DN125 56 115 240 118 190 75 260 210 8-M16 8.8 8.4
D6150L..MH DN150 56 142 257 132 210 75 260 240 8-M20 10.4 9.7

D650...250L..MW D6300...450L..MW D6500L..MW

Dimensions of PN16 lug connection worm gear Butterfly Valves [mm]

PN16 NC SS
Type Size L C S H1 H2 H3 A øF BFV BFV
øD n-M (kg) (kg)
D650L..MW DN50 43 33 115 65 130 48 160 140 125 4-M16 4.1 4.1
D665L..MW DN65 46 48 132 71 143 48 160 140 145 4-M16 4.7 4.7
D680L..MW DN80 46 66 175 92 155 48 160 140 160 8-M16 5.8 5.7
D6100L..MW DN100 46 66 175 92 155 48 160 140 180 8-M16 7.5 7.3
D6125L..MW DN125 56 115 240 118 190 56 140 140 210 8-M16 11.9 11.6
D6150L..MW DN150 56 142 257 132 210 56 140 140 240 8-M20 13.5 12.9
D6200L..MW DN200 60 194 318 167 243 80 200 220 295 12-M20 21.1 19.8
D6250L..MW DN250 68 245 383 198 282 80 200 220 355 12-M24 30.4 28.2
D6300L..MW DN300 78 294 435 231 310 81 213 300 410 12-M24 44.0 46.1
V7.3 08.2015• Subject to modification

D6350L..MW DN350 78 328 512 256 345 81 213 300 470 16-M24 63.6 62.2
D6400L..MW DN400 102 374 590 294 377 120 251 400 525 16-M27 102.4 104.6
D6450L..MW DN450 114 425 640 337 422 120 251 400 585 20-M27 128.8 130.9
D6500L..MW DN500 127 472 703 375 466 124 254 300 650 20-M30 180.3 181.1

UL marked actuators is optional, please contact your local Sales Representative for details. 61
D6..AB Series Butterfly Valves
Trade Selection by Belimo

2-way Butterfly Valves flanged


DN50...800

For Open/Close or modulating control of sea water and brine


Applications
Typical applications include large heat-exchanger.

Technical data
Flow medium Sea water and brine
Temperature of medium Aluminium Bronze disc: -10...+80°C
Nominal pressure 1600kPa (PN16)
Flow characteristic Modified equal-percentage
Rangeability 10:1 (for 30°... 70° range)
Leakage rate Rate A Bubble Tight (ISO 5208)
Pipe connections ISO 7005.2, AS2129
PN10/16, Table E for wafer (DN50..300)
PN16 for wafer (DN350...800)
Max. Close-off pressure 1200kPa (DN50...600)
1000kPa (DN700...800)
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN50..800)
Disc Aluminium Bronze disc
Seat NBR
Shaft Stainless steel 416
Bushing RPTFE

Default: D6700..800AB Butterfly Valve and its Actuator are pre-calibrated and pre-assembled in the factory.

Ordering sample
D6 125 AB

Aluminium Bronze disc

Size: DN125

Butterfly Valve: D6.. series

Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.

Mode of operation
The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/ Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.

Manual operation
The manual operation is available by using a lever with manual override button of SR..,
V7.3 08.2015• Subject to modification

GR.., DGR.. actuator pressed or turning a handwheel of actuators.

62 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..AB Series Butterfly Valves
Trade Selection by Belimo

D650AB...D6600AB D6700AB...D6800AB

Dimensions of PN16 wafer connection Butterfly Valve [mm]

Top PN10 PN16 Table E Weight


Type Size L C S H1 H2 H3 H4 G ød1
Flange øD n-ød øD n-ød øD n-ød (kg)
D650AB DN50 F05 43 33 118 65 130 13 9 14 65 125 4-18 125 4-18 114 4-18 1.99
D665AB DN65 F05 46 48 135 71 143 13 9 14 65 145 4-18 145 4-18 127 4-18 2.45
D680AB DN80 F05 46 66 149 92 155 13 9 14 65 160 8-18 160 8-18 146 4-18 2.8
D6100AB DN100 F05 52 91 150 104 170 13 11 14 65 180 8-18 180 8-18 178 8-18 4.2
D6125AB DN125 F07 56 115 176 118 190 19 13 17 90 210 8-18 210 8-18 210 8-18 6.5
D6150AB DN150 F07 56 142 204 132 210 19 13 17 90 240 8-22 240 8-22 235 8-22 8.2
D6200AB DN200 F07 60 194 260 167 243 19 15 17 125 295 8-22 295 12-22 292 8-22 12.4
D6250AB DN250 F10 68 245 316 198 282 24 17 22 125 350 12-22 355 12-26 356 12-22 19.7
D6300AB DN300 F10 78 294 372 231 310 24 17 22 125 400 12-22 410 12-26 406 12-26 31.7
D6350AB DN350 F10 78 328 422 256 345 24 20 22 125 - - 470 16-26 - - 41.1
D6400AB DN400 F14 102 374 473 294 377 38 21 36 175 - - 525 16-30 - - 65.9
D6450AB DN450 F14 114 425 526 337 422 38 21 36 175 - - 585 20-30 - - 82.2
D6500AB DN500 F14 127 472 582 375 466 38 22 36 210 - - 650 20-33 - - 104.4
D6600AB DN600 F16 154 573 708 459 562 52 29 36 210 - - 770 20-36 - - 185

Dimensions of PN16 wafer connection Butterfly Valve [mm]

PN16
Type Size L C S H1 H2 4-M Weight (kg)
øD n-ød
D6700AB DN700 163 674 910 540 631 M33 840 20-36 391
D6800AB DN800 188 770 1025 607 674 M36 950 20-39 469.2
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 63
The Sizing of D6...AB Series Butterfly Valves
Trade Selection by Belimo

Kv Value [m3/h]

Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
D650AB DN50 2” 80 75 57 39 27 21 16 6.9 1.09
D665AB DN65 2.5” 170 142 99 64 42 30 19 7.5 5.2
D680AB DN80 3” 290 278 205 139 87 51 34 21 7.7
D6100AB DN100 4” 560 404 270 137 105 67 46 26 6.3
D6125AB DN125 5” 870 744 502 306 186 113 60 33 15.6
D6150AB DN150 6” 1340 1185 720 472 294 171 94 47 25.9
D6200AB DN200 8” 2690 2360 1483 956 617 362 211 88 52
D6250AB DN250 10” 5540 3948 2364 1502 911 588 334 193 84.5
D6300AB DN300 12” 7540 6147 3607 2083 1229 706 401 164 4.13
D6350AB DN350 14” 10300 9348 6233 3938 2380 1335 616 291 5.2
D6400AB DN400 16” 14300 12856 8571 5416 3237 1836 847 400 6.9
D6450AB DN450 18” 18900 17028 11352 7172 4334 2433 1122 530 9.5
D6500AB DN500 20” 24200 21893 14596 9222 5573 3128 1443 682 12
D6600AB DN600 24” 37169 33901 22549 14248 8611 4832 2230 1053 22
D6700AB DN700 28” 42672 30084 19628 12887 8621 5721 3137 1563 36
D6800AB DN800 32” 58836 41480 27065 17770 11886 7531 4130 2058 45

Max. Close-off Pressure Ps and linkage — D6..AB series

IP54 Actuator (Indoor Use)


SR..A(-..)-5 GR..A-5/-7 DR..A(-..)-7
Type [20Nm] [40Nm] [72Nm]

Ps Ps Ps
kPa kPa kPa
D650AB 1200 - -
D665AB 1200 - -
D680AB 1200 - -
D6100AB - 1200 -
D6125AB - - 1200
D6150AB - - 1200

IP67 Actuator (Outdoor Use)


SY1.. SY2.. SY3.. SY4.. SY6.. SY7.. SY8.. SY12.. QB8000.. QB10000..
Type [35Nm] [90Nm] [150Nm] [400Nm] [650Nm] [1000Nm] [1500Nm] [3500Nm] [8000Nm] [10000Nm]

Ps Ps Ps Ps Ps Ps Ps Ps Ps Ps
kPa kPa kPa kPa kPa kPa kPa kPa kPa kPa

D650AB 1200 - - - - - - - - -
D665AB 1200 - - - - - - - - -
D680AB 1200 - - - - - - - - -
D6100AB 1200 - - - - - - - - -
D6125AB - 1200 - - - - - - - -
D6150AB - 1200 - - - - - - - -
D6200AB - - 1200 - - - - - - -
D6250AB - - - 1200 - - - - -
D6300AB - - - 1200 - - - - - -
D6350AB - - - - 1200 - - - - -
D6400AB - - - - - 1200 - - - -
D6450AB - - - - - - 1200 - - -
D6500AB - - - - - - 1200 - -
V7.3 08.2015• Subject to modification

D6600AB - - - - - - - 1200 - -
D6700AB - - - - - - - - 1000 -
D6800AB - - - - - - - - - 1000

64 UL marked actuators is optional, please contact your local Sales Representative for details.
D6..D(S) Series Butterfly Valves
Trade Selection by Belimo

2-way Butterfly Valves


DN600...1200

For Open/Close or modulating control of cold and hot water.


Applications
Typical applications include chiller isolation, cooling tower
isolation and bypass control, change-over systems.

Technical data
Flow medium Nylon coated disc: Cold and hot water
SS304 disc: cold and hot water. Max. 50% Glycol
Temperature of medium Nylon-coated disc: Cold water and hot water, 0...+95°C
SS304 disc: -20...+100°C
Nominal pressure 1600kPa (PN16)
Leakage rate Rate A Bubble tight (ISO 5208)
Pipe connections * ISO 7005.2 PN16 wafer
Max. Close-off pressure 1200kPa (DN600)
1000kPa (DN700...1200)
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG40 (DN600...1200)
Disc Nylon coated ductile cast iron disc / Stainless steel 304 disc
Seat EPDM
Stem Stainless steel 416
Bushing RPTFE

Default: D6700...1200D(S) Butterfly Valve and its Actuator are pre-calibrated and pre-assembled in the factory.

Ordering sample
D6 700 DS

S - stainless steel 304 disc


Default - nylon coated disc

Size: DN700

Butterfly Valve: D6.. series

Product features
The modified equal-percentage flow characteristic and the large Kv values provide an eco-
nomical control valve solution.

Mode of operation

The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.

Manual operation
The manual operation is available by turning a handwheel of actuators.
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 65
Dimensions of D6..D(S) Series Butterfly Valves
Trade Selection by Belimo

D6600D(S) D6700D(S)... D61200D(S)

Dimensions of PN16 wafer connection Butterfly valves [mm]

Top PN16 Weight


Type Size L C S H1 H2 H3 G ød1
Flange øD n-ød (kg)
D6600D(S) DN600 F16 154 573 708 459 562 52 36 210 770 20-36 185

PN16 Weight
Type Size L C S H1 H2 4-M
øD n-ød (kg)
D6700D(S) DN700 163 674 910 540 631 M33 840 20-36 284
D6800D(S) DN800 188 770 1025 607 674 M36 950 20-39 368
D6900D(S) DN900 203 839 1125 656 720 M36 1050 24-39 713
D61000D(S) DN1000 216 939 1255 727 802 M39 1170 24-42 865
D61200D(S) DN1200 276 1124 1485 866 941 M45 1390 28-48 1545

Kv Value [m3/h]

Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°

D6600D(S) DN600 24” 37169 33901 22549 14248 8611 4832 2230 1053 22
D6700D(S) DN700 28” 42672 30084 19628 12887 8621 5721 3137 1563 36
D6800D(S) DN800 32” 58836 41480 27065 17770 11886 7531 4130 2058 45
D6900D(S) DN900 36” 74461 52496 34251 22488 15042 9530 5227 2604 60
D61000D(S) DN1000 40” 103232 72780 47486 31178 20827 13195 7237 3606 84
D61200D(S) DN1200 48” 132284 92731 60851 39711 26457 16932 9259 4629 106
V7.3 08.2015• Subject to modification

66 UL marked actuators is optional, please contact your local Sales Representative for details.
The Sizing of D6..D(S) Series Butterfly Valves
Trade Selection by Belimo

Max. Close-off Pressure Ps and linkage — D6..D(S) series

IP67 Actuator (Outdoor Use)


SY12.. QB8000.. QB10000.. QB12000.. XZA17500.. XZA23000..
Type [3500Nm] [8000Nm] [10000Nm] [12000Nm] [17500Nm] [23000Nm]
Ps Ps Ps Ps Ps Ps
kPa kPa kPa kPa kPa kPa
D6600D 1200 - - - - -
D6700D - 1000 - - - -
D6800D - - 1000 - - -
D6900D - - - 1000 - -
D61000D - - - - 1000 -
D61200D - - - - - 1000

IP67 Actuator (Outdoor Use)


SY12.. QB8000.. QB10000.. QB12000.. XZA17500.. XZA23000..
Type [3500Nm] [8000Nm] [10000Nm] [12000Nm] [17500Nm] [23000Nm]
Ps Ps Ps Ps Ps Ps
kPa kPa kPa kPa kPa kPa
D6600DS 1200 - - - - -
D6700DS - 1000 - - - -
D6800DS - - 1000 - - -
D6900DS - - - 1000 - -
D61000DS - - - - 1000 -
D61200DS - - - - - 1000
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 67
D6.. H Series Butterfly Valves
Trade Selection by Belimo

2-way Butterfly Valves flanged


DN50...500

For 2-point or modulating control of cold and hot water.


Applications
Typical applications include chiller isolation, cooling tower isolation,
change-over systems, large air handling coil control, bypass and
process control.

Technical data
Flow medium Cold and hot water, Max. 50% glycol
Temperature of medium -20°C...+100°C
Nominal pressure 2500kPa (PN25)
Leakage rate Rate A Bubble tight (ISO 5208)
Pipe connections * ISO 7005.2 PN25 lug DN50...500
Max. Close-off pressure 2200kPa
Installation position Vertical to horizontal
Maintenance Maintenance-free
Angle of rotation 90° rotation
Valve Material
Body Ductile cast iron GGG50 (DN50...500)
Disc Stainless steel 304
Seat EPDM
Shaft Hardened and tempered 45 carbon steel
Bushing RPTFE
Default: D6500H Butterfly Valve and its actuator are pre-calibrated and pre-assembled in the factory.

Ordering sample
D6 125 H

Nominal pressure: 2500kPa

Size: DN125

Butterfly Valve: D6.. series

Mode of operation
The Butterfly Valve is operated by a Rotary Actuator. Select the actuator according to
required Close-off pressure and HVAC condition of installation. The actuators are controlled
by a standard Open/Close or modulating control system and rotate the disc of the valve to
the position dictated by the control signal.

Manual operation
The manual operation is available by turning a handwheel of actuators.

Kv Value [m3/h]

Type Size 90° 80° 70° 60° 50° 40° 30° 20° 10°
D650H DN50 2” 117 108 78 55 39 21 10 4 0.1
D665H DN65 2.5” 190 176 125 85 56 32 17 7 0.2
D680H DN80 3” 261 238 158 100 61 34 19 10 0.3
D6100H DN100 4” 519 47 315 199 120 67 31 15 0.4
D6125H DN125 5” 884 804 536 339 205 115 53 25 0.7
D6150H DN150 6” 1366 1243 829 523 317 177 82 39 2
V7.3 08.2015• Subject to modification

D6200H DN200 8” 2713 2469 1646 1040 629 353 163 77 3


D6250H DN250 10” 4619 4203 2803 1771 1070 600 277 131 3
D6300H DN300 12” 7137 6494 4330 2735 1653 927 428 202 4
D6350H DN350 14” 10309 9381 6254 3952 2388 1340 619 292 5
D6400H DN400 16” 14176 12901 8600 5434 3285 1843 850 401 7
D6450H DN450 18” 18776 17087 11391 7197 4349 2441 1126 532 10
D6500H DN500 20” 24142 21969 14646 9254 5593 3138 1448 684 12

68 UL marked actuators is optional, please contact your local Sales Representative for details.
Dimensions of D6..H Series Butterfly Valves
Trade Selection by Belimo

Dimensions of PN25 lug connection Butterfly Valve [mm]

Top PN25 SS BFV


Type Size L C S H1 H2 H3 G ød1
Flange øD n-M (kg)

D650H DN50 F05 42 32 122 70 130 13 14 65 125 4-M16 3.2


D665H DN65 F05 45 47 168 76 143 13 14 65 145 8-M16 3.8
D680H DN80 F05 45 65 178 89 155 13 14 65 160 8-M16 5.0
D6100H DN100 F07 52 91 212 104 170 17 17 90 190 8-M20 9.0
D6125H DN125 F07 55 112 243 120 190 25 22 90 220 8-M24 11.3
D6150H DN150 F07 56 146 271 132 210 43 22 90 250 8-M24 15.0
D6200H DN200 F10 61 194 339 167 243 25 22 125 310 12-M24 20.0
D6250H DN250 F10 66 242 402 202 282 25 22 125 370 12-M27 30.0
D6300H DN300 F12 77 292 466 239 310 60 36 150 430 16-M27 46.0
D6350H DN350 F12 77 325 529 265 368 66 36 150 490 16-M30 70.3
D6400H DN400 F16 87 380 593 299 400 50 36 210 550 16-M33 88.5
D6450H DN450 F16 105 428 647 333 422 50 36 210 600 20-M33 104.4
D6500H DN500 - 130 474 706 363 480 - - - 660 20-M33 179.6

Max. Close-off pressure Ps and linkage — D6..H series

IP67 Actuator (Outdoor Use)


SY2.. SY3.. SY4.. SY6.. SY8.. SY10.. SY11.. SY12.. QB6000..
Type [90Nm] [150Nm] [400Nm] [650Nm] [1500Nm] [2500Nm] [3000Nm] [3500Nm] [6000Nm]
Ps Linkage Ps Ps Ps Ps Ps Ps Ps Ps Ps
kPa WD6.. kPa kPa kPa kPa kPa kPa kPa kPa kPa
D650H 2200 S2 - - - - - - - - -
D665H 2200 S2 - - - - - - - - -
D680H 2200 S2 - - - - - - - - -
D6100H - - 2200 - - - - - - - -
D6125H - - - 2200 - - - - - - -
D6150H - - - - 2200 - - - - - -
D6200H - - - - 2200 - - - - - -
D6250H - - - - - 2200 - - - - -
D6300H - - - - - - 2200 - - - -
V7.3 08.2015• Subject to modification

D6350H - - - - - - - 2200 - - -
D6400H - - - - - - - - 2200 - -
D6450H - - - - - - - - - 2200 -
D6500H - - - - - - - - - - 2200

UL marked actuators is optional, please contact your local Sales Representative for details. 69
Complementary Products
Trade Selection by Belimo

• General Actuators for: DN600...1200 Butterfly Valves


• Torque: 6000...23000Nm
• Open/Close control: QB6000.., QB8000.., QB10000..,
QB12000.., XZA17500.., XZA23000..
• Modulating control: QB6000P.., QB8000P.., QB10000P..,
QB12000P.., XZA17500P.., XZA23000P..

Technical data
Electrical Data Nominal voltage AC 380V ±10% 3-PH, 50/60Hz*
Nominal voltage range AC 342...418V 3-PH, 50/60Hz
Connecting cable M33 cable connector, screw terminals
Motor protection F class
Gear train Steel
Control/Position feedback signal DC 4..20mA
Sensitivity 1% input signal
Angle of rotation 90°
Position indicator Top mounted domed indication
Ambient temp. QB.. -20°C..+50°C
XZA.. -20°C..+55°C
Humidity 5...95% RH, non-condensing
Degree of protection IP67
Manual Operation Manual by override handwheel
Housing material Cast iron
*3-phase AC 415V for QB../XZA.. actuator is available on request.

Motorpower for
Model Torque Running time 90° Running current Weight
reference Manual override
No. (Nm) (s) of motor (A) (kg)
(kW)

QB6000.. 6000 0.55 60 2.50 Handwheel 120

QB8000.. 8000 1.10 60 3.40 Handwheel 210

QB10000.. 10000 1.50 60 3.70 Handwheel 210

QB12000.. 12000 2.20 60 4.50 Handwheel 210

XZA17500.. 17500 3.00 50 6.50 Handwheel 395

XZA23000.. 23000 4.00 56 13.00 Handwheel 560

Ordering sample

QB8000 P -50

50 - 50Hz motor eg: Modulating control


60 - 60Hz motor QB10000P-50
Open/Close control
Default - Open/Close QB10000-50
P - modulating control 4...20mA

Model Number
V7.3 08.2015• Subject to modification

70 UL marked actuators is optional, please contact your local Sales Representative for details.
Complementary Products
Trade Selection by Belimo

Wiring diagrams

QB.. Open/Close control Terminal

XZA.. #1 Power supply Hot line


1 2 3 4 5 6 7 8 9 10 11 #2 Power supply Hot line

#3 Power supply Hot line

100% #5 Switch for stop SS1

#6 Switch for Open SO1

Notes: #7 Switch for Close SC1


L1 L2 L3 SS1 SO1 SC1 0%
• Caution: Power supply voltage! ! AC 380V DC 24V
#8 Com

• Relays are needed in parallel connection of #9 Com


Passive contact
several actuators. #10 Feedback of fully Open
• Maximal 10 min. of duty cycle. #11 Feedback of fully Close

Remote Switch Remote(Terminal 5-8)

St op
Control method
Close
Local operation switch

Open

QB.. Modulating control Terminal

XZA.. 1 2 3 4 5 6 7 8 9 10 11 12 #1 Power supply Hot line

#2 Power supply Hot line

SSE1 #3 Power supply Hot line

#5 Signal Remote
Auto 100% Switch Remote/Signal Remote
SO1 SC1 #6
Selection SSE1

Notes: #7 Switch for open SO1


L1 L2 L3
• Caution: Power supply voltage! ! SS1
0% #8 Switch for close SC1

• The control signal has to be separated from AC 380V DC 24V #9 Com


the others and shielded. Passive contact #10 Com
• Maximal 10 min. of duty cycle.
#11 Feedback of fully Open

#12 Feedback of fully Close

#17 Output Signal +

#18 Output Signal -

#19 Input Signal +

#20 Input Signal -


17 18 19 20

Signal Remote (Terminal 17-20)


Jumper wire must be connected between Terminal 5 and 6

Remote

Switch Remote (Terminal 5-8)


St op

Control method

Close
Local operation switch

Open
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 71
Complementary Products
Trade Selection by Belimo

Dimensions [mm]

QB..

Type A1 B øD øD1 øD2 m E H H2 L L1


QB6000.. 134 180 457 240 230 368 21 204 417 262 510
QB8000...12000.. 164 212 457 240 270 388 21 247 496 410 710

XZA..

Type L1 L2 L3 L4 B1 B2 H1 H2 H3 H4 H6 øF
XZA17500.. 197 580 98 1156 121 258 801 233 443 246 446 305
V7.3 08.2015• Subject to modification

XZA23000.. 248 580 98 1156 127 280 848 255 440 246 471 305

72 UL marked actuators is optional, please contact your local Sales Representative for details.
Butterfly Valves Installation Guideline and Recommendation

Installation and maintenance guidelines


Pre-installation procedure 1. Check BFV identification tag for materials and type codes to ensure they are correct for
application with its technical specifications.
2. Actuator should be mounted and calibrated on the BFV in prior to installation to facilitate
proper alignment of disc-seat sealing.
3. Make sure the pipeline and the face of pipe connection flanges are clean. Any foreign
material such as rust, pipe scale, metal clips, welding slages, etc. can obstruct disc move-
ment and damage the seat and disc sealing surfaces.
4. Check the bolts or stud screws for proper pipe connection flanges thread and length, etc.
5. Belimo elastomer seat has molded O-ring on the face of seat. As a result, no gaskets are
required as these O-rings serve the function of gasket.
Installation procedure 1. Align the piping and then spread the pipe flanges a distance apart enough to permit the
BFV body to be easily dropped between the flanges without actually contacting the pipe
flanges’ face. (See figure 1). Particular care in handling the BFV so as to prevent further
Warning! damage to the disc or seat faces.
Personal injury or property 2. Check to see that the BFV disc has been positioned to a partially open position, with the
damage may result
disc edge approximately 10° open from the face of the seat ( See figure 2).
if the valve is installed
where service conditions could 3. Insert the BFV between flanges. Always lift the BFV by locating holes or by using a nylon
exceed the valve ratings. sling on the neck of the body. Never pick up the BFV by actuator or operator mounted on
the top of the BFV.
4. Place the BFV between the flanges, centre it and then span the BFV body with all flange
Warning!
bolts by hand, but do not tighten the bolts.
Never complete the welding 5. Carefully open and close the disc to fully open and fully closed position freely without any
process (after tacking) with the
valve between pipe flanges.
obstruction. Make sure the disc edge does not hit the adjacent pipe I.D.
This causes severe seat 6. Systematically remove jack bolts or other flange spreaders, and hand tighten the flange
damage due to heat transfer.
bolts.(See figure 2)
7. Very slowly close the disc to ensure disc edge clearance from adjacent pipe flange I.D.
Open the disc to fully open and tighten all flange bolts as per specification. (See figure 2)
8. Cycle the BFV to fully open and fully closed position. Check the actuator travel stop set-
tings are synchronised to proper disc alignment and edge clearance. (See Figure 3 and
4)
9. The BFV is now ready for operation.
Safety precautions Before removing the BFV from the pipeline or loosening any bolts, it is important to verify
the following conditions:
1. Make sure the pipeline is depressurised and drained.
2. Care for the flow media. Proper care should be taken for protection against toxic and/or
flammable fluids.
3. Practise caution if removing the actuator from the BFV when the pipeline is under pres-
sure. The disc may move suddenly due to the pressure.
4. Always be sure that the disc is in the closed position before removing the BFV.
General maintenance The following periodic preventative maintenance practices are recommended for all But-
terfly Valves:
1. Operate the valve from fully open to fully closed to assure operability.
2. Check flange bolting for evidence of loosening and correct.
3. Inspect the valve and surrounding area for previous or existing leakage at flange faces or
shaft connections.
4. Check piping and/or wiring to actuators and related equipment for looseness and correct
as needed.
90° 90°

Recommended installation position The butterfly valves may be mounted either vertically
or horizontally.
The butterfly valves may not be installed in a hanging
position i.e. with the stem pointing downwards.
V7.3 08.2015• Subject to modification

73
Butterfly Valves Installation Guideline and Recommendation

Installation and maintenance guidelines


Figure 1 Initial installation of valve

INCORRECT CORRECT

Disc opened beyond valve body face. Disc positioned in the “almost closed” position.
Pipe flanges not spread sufficiently. Pipe flanges spread allowing sufficient room for valve.
Figure 2 Recommended Bolt Tightening Sequence

1 13
1 5 15 5
8 9 8
9
12 3 12 3

4 11 4 11

10 7 10 7
6 2 6 16
14 2

Figure 3 Centring and flanging of valve

gaskets

INCORRECT CORRECT
Disc in “closed” position. Gaskets in- No flange gaskets used. Disc in the “almost
stalled between valve and mating flanges closed” position.
Figure 4 Final valve alignment and tightening of flange bolts

INCORRECT CORRECT
Pipe flanges mis-aligned. Uneven torque Piping aligned. Thread engagement even on
applied to bolting. both sides of valve.
Figure 5 Installation notes for DN700..1200 BFV
V7.3 08.2015• Subject to modification

INCORRECT CORRECT
Large size BFV with 2 flanges is wafer connected.

74
Butterfly Valves Installation Guideline and Recommendation

Location and orientation in piping recommendation

Valve Location: • Butterfly valves should be installed if possible a minimum of 6 pipe diameters from other
line elements, i.e., elbows, pumps etc.
• Where the butterfly valve is connected to a check valve or pump, use an expansion joint
between them to ensure the disc does interfere with the adjacent equipment.

For Centrifugal Pump - Pump shaft horizontal and stem vertical

Pump Shaft Pump Shaft


(Horizontal) (Horizontal)

W W

FLOW F FLOW

Stem (Horizontal) S Stem (Vertical)

INCORRECT CORRECT

For Centrifugal Pump - Pump shaft vertical and stem vertical

Pump Shaft (Vertical) Pump Shaft (Vertical)

FLOW FLOW

Stem Stem
(Horizontal) (Vertical)

Suction Suction
INCORRECT CORRECT

Axial Pump - Pump shaft vertical and stem vertical

Pump Shaft Pump Shaft


(Vertical) (Vertical)

FLOW FLOW

Stem Stem
(Horizontal) (Vertical)

Suction Suction

INCORRECT CORRECT

Butterfly Valves Located Downstream of a Bend or Pipe Reducer


Figure 1 Bend

Stem Stem
(Horizontal) (Vertical)

FLOW FLOW
V7.3 08.2015• Subject to modification

INCORRECT CORRECT

75
Butterfly Valves Installation Guideline and Recommendation

Location and orientation in piping recommendation (continued)


Figure 2 Tee

Stem Stem
(Horizontal) (Vertical)

FLOW FLOW

INCORRECT CORRECT
Figure 3 Pipe Reducer
Stem Stem
(Horizontal) (Vertical)

FLOW FLOW

INCORRECT CORRECT

Butterfly Valves in combination for control/isolation applications:

FLOW FLOW
INCORRECT CORRECT
Combination with all valve stems in the same Combination with stem of the control valve at right angle
direction accelerates possible noise, vibration and to those of other valves tends to cancel the drift of the
erosion problems. fluid, and reduces noises, vibration and erosion.

Flange Dimensions for Butterfly Valves Recommendation

Flange Connection Standard Reference PN25 PN16

ISO 7005.2 DN D H DN D H
(mm) (mm) (mm) (mm) (mm) (mm)
GB/T 9113.1
50 50 4 50 50 4
GB/T 17241.6 65 65 4 65 65 4
80 80 4 80 80 4
100 100 4 100 100 4
125 125 4 125 125 4
150 150 4 150 150 4
200 208 5 200 208 5
250 250 6 250 255 6
300 308 6 300 308 6
350 340 7 350 340 7
400 405 7 400 405 7
450 455 8 450 455 8
500 505 8 500 505 8
- - - 600 605 8
V7.3 08.2015• Subject to modification

- - - 700 705 9
- - - 800 810 9
- - - 900 900 9
- - - 1000 1000 10
- - - 1200 1200 10

76
SR..A(-..)-5 Mounting Instructions

1 2
R6..W.. F05 = 14

2 BU6..
D6..
R6..W.. BU6..
D6..
1 2
100% 0%

F05
10Nm
10

D6..
BU6..

4
A M

B M
V7.3 08.2015• Subject to modification

C M

77
GR..A-5 / -7 Mounting Instructions

1 2
R6..W.. F05 = 14
F07 = 17

2 BU6..
D6..
R6..W.. BU6..
D6..
1 2
100% 0%

F05
10Nm
10

BU6..
D6..
F07
22Nm
13

4
A M

B M
20

V7.3 08.2015• Subject to modification

C M

78
DR..A(-..)-7 Mounting Instructions

1 2
1

17
2 0%

F07
22Nm
13
V7.3 08.2015• Subject to modification

79
SRF(..)A(-..)-5 Mounting Instructions

NC NO

D6..
D6..

3 3

1 1

.9 9.

2 2
.8 8.
.7 7.
6 6

BU6.. BU6..

3 3
4x 4x

10
10

10 Nm 10 Nm

33 ... 100% NO NC

Y= 0 Y= 0

.9
.8
.7
.6
.5
.4
.3
.2 .1
V7.3 08.2015• Subject to modification

.2
.4

.6
.8

80
GRK..A(-..)-5 / -7 Mounting Instructions

1 R6..W.. 2
F05 = 14
F07 = 17

BU6..
2 D6..

1 2 R6..W.. BU6..
D6..

100% 0%

F05
10Nm
10

BU6..
D6..
F07
22Nm
13

4 1

M
2
V7.3 08.2015• Subject to modification

20

81
82
2

4
SY.. Mounting Instructions

45
3
2

V7.3 08.2015• Subject to modification


V7.3 08.2015• Subject to modification SY1U24-SR-T / SY1U230-SR-T Modulating Actuator

83
SY(2...5)U24-SR/MF/MP-T / SY(2...9)U230-SR/MF-T Actuator

V7.3 08.2015• Subject to modification

84
V7.3 08.2015• Subject to modification SY..-3-T Open/Close or 3-point Actuator

85
WD6S2 Linkage Kit Installation Instructions

V7.3 08.2015• Subject to modification

86
Manual Handle and Worm Gear for Butterfly Valves
Trade Selection by Belimo

Manual Handle and Worm Gear


for Butterfly Valves

Applications
For manually operating D6..AB, D6..D(S) series
butterfly valves.

Technical data
Materials
Worm Gear Gear train Ductile cast iron and steel gear sets
Housing ZD6-W100~ZD6-W250 Cast Aluminium
ZD6-W350~ZD6-W1200 Cast Iron
Shaft Steel 45
Hand wheel Cast iron
Handle ZD6-H100~ZD6-H150 Cast Aluminium
Stop Plate Steel

Ordering sample

ZD6 H 100 ZD6 W 100

Size: For BFV DN100 Size: For BFV DN50...100

H: Handle W: Worm Gear

Manual Operator Manual Operator

Dimensions [mm]

Manual Handle

Dimensions [mm]
Top Weight
Type
Flange (kg)
A HB HC

ZD6-H100 F05, 14x14 170 32 64 0.50


ZD6-H100~ZD6-H150 ZD6-H150 F07, 17x17 260 37 75 0.65
V7.3 08.2015• Subject to modification

UL marked actuators is optional, please contact your local Sales Representative for details. 87
Manual Handle and Worm Gear for Butterfly Valves
Trade Selection by Belimo

Dimensions

Worm Gear

Single-stage Worm Gear Single-stage Worm Gear Double-stage Worm Gear


ZD6-W100 ~ ZD6-W250 ZD6-W350 ~ ZD6-W450 ZD6-W500 ~ ZD6-W1200

Dimensions [mm] Weight


Type Top flange Speed Ratio
A A1 A2 L S øF (kg)
ZD6-W100 F05, 14x14 128 63 152 50 90 140 24:1 1.4
ZD6-W150 F07, 17x17 128 63 152 50 90 140 24:1 1.4
ZD6-W200 F07, 17x17 180 82.5 262 60 119 300 30:1 3.2
ZD6-W250 F10, 22x22 180 82.5 262 60 119 300 30:1 3.2
ZD6-W350 F10, 22x22 213 77.5 197.5 80.8 152 300 50:1 9.1
ZD6-W450 F14, 36x36 251 120 287.5 120 230 400 80:1 20.7
ZD6-W500 F14, 36x36 169 100 361 124 214 300 560:1 27
ZD6-W600 F16, 36x36 191 125 417 129 276 300 640:1 56
ZD6-W800 F25-Key18 224 140 481 131 300 400 726:1 75
ZD6-W900 F25-Key20 248 162 534 191 354 450 704:1 106
ZD6-W1000 F25-Key22 248 162 534 191 354 450 704:1 106
ZD6-W1200 F25-Key28 314 236 626 252 500 450 800:1 281

V7.3 08.2015• Subject to modification

88 UL marked actuators is optional, please contact your local Sales Representative for details.
Market Asia Pacific
ASIA PACIFIC HEADQUARTERS Japan Office:
Belimo Actuators Ltd. Belimo Actuators Ltd.
Room 1601-6, 16/F, New Commerce Centre 2nd Floor, Yamaki Building III
19 On Sum Street, Shatin, N.T., Hong Kong 3-1-5 Azumabashi, Sumida-ku
Tel: +852 2687 1716 Tokyo 130-0001, Japan
Fax: +852 2687 1795 Tel: +81 3 6823 6961
E-mail: info.asiapacific@belimo.ch Fax: +81 3 3626 3911
E-mail: info.japan@belimo.ch
Belimo AUSTRALIA
Melbourne Office: Malaysia Office:
Belimo Actuators Pty. Ltd. Belimo Actuators Ltd
12 Enterprise Court S-13-12, First Subang, Jalan SS15/4G
Mulgrave Business Park 47500 Subang Jaya, Selangor, Malaysia
Mulgrave, VIC 3170, Australia Tel: +03-56125833
Tel: +61-(0)3-8585 7800 Fax: +03-56125233
Fax: +61-(0)3-8585 7811 E-mail: info.malaysia@belimo.ch
E-mail: info.australia@belimo.ch Singapore Office
Belimo Actuators Ltd.
Sydney Office: 1 Tannery Road #08-04
Belimo Actuators Pty. Ltd. One Tannery, Singapore 347719
Suite 2.20, 32 Delhi Road Tel: +65 6842 1626
North Ryde, NSW 2113, Australia Fax: +65 6842 1630
Tel: +61 (0)2 9805 1777 E-mail: info.singapore@belimo.ch
Fax: +61 (0)2 9805 1722
E-mail: info.australia@belimo.ch Taiwan Office:
Belimo Actuators Ltd.
Belimo CHINA 7F-2, No.343, Jhonghe Rd., Yonghe District
Shanghai Office: New Taipei City 234, Taiwan
Belimo Actuators (Shanghai) Trading Ltd. Tel: +886 2 2922 8805
479 Chun Dong Road, Building C-2 Fax: +886 2 2922 8806
Xin Zhuang Industry Park E-mail: info.taiwan@belimo.ch
Shanghai 201108, P.R. China
Thailand Office:
Tel: +86 21 5483 2929
Belimo Actuators Ltd.
Fax: +86 21 5483 2930
90/2 Pensiri Place, Soi Phaholyothin 32
E-mail: info.shanghai@belimo.ch
Phaholyothin Road, Chandrakasem, Jatujak
Beijing Office: Bangkok 10900, Thailand
Belimo Actuators Ltd. Tel: +662 9415582-3
Unit 1528-1530, 15F, Tower A Fax: +662 9415584
Jiatai International Mansion E-mail: info.thailand@belimo.ch
No. 41, Middle East Fourth Ring Road
Chaoyang District, Beijing,100025, Belimo INDIA
P.R. China Mumbai Office:
Tel: +86 10 6462 1382/1386 Belimo Actuators India Pvt. Ltd.
Fax: +86 10 6462 1383 23/ ABCD, Govt. Industrial Estate, Charkop
E-mail: info.beijing@belimo.ch Kandivali West, Mumbai 400067, India
Tel: +91 22 4025 4800
Guangzhou Office: Fax: +91 22 4025 4899
Belimo Actuators Ltd. E-mail: info.india@belimo.ch
Room 5217-5218, China International Centre,
Tower B, 33 Zhong Shan San Road, Yuexiu District, Bangalore office:
Guangzhou 510055, P.R. China Belimo Actuators India Pvt. Ltd.
Tel: +86 20 3435 1860 Sreerama Complex, No. 13, 2nd Floor
Fax: +86 20 3435 1870 5th Cross Road, 6th Block, Koramangala
E-mail: info.guangzhou@belimo.ch Bangalore – 560097, India
Tel: +91-80-40906311
Belimo HONG KONG Fax: +91-80-40906288
Hong Kong Office: E-mail: info.india@belimo.ch
Belimo Actuators Ltd.
New Delhi Office:
Room 1601-6, 16/F, New Commerce Centre
Belimo Actuators India Pvt. Ltd.
19 On Sum Street, Shatin, N.T., Hong Kong
Flat No. 515, DLF Tower – B
Tel: +852 2687 1716
Jasola Distt. Centre, Jasola
Fax: +852 2687 1795
New Delhi 110025, India
E-mail: info.hongkong@belimo.ch
Tel: +91 11 41078501
Fax: +91 11 41078508
Indonesia Office:
E-mail: info.india@belimo.ch
Belimo Actuators Ltd.
Graha Kencana Building 8th Floor Block B Chennai Office:
Jl. Raya Perjuangan 88 Belimo Actuators India Pvt. Ltd.
Kebon Jeruk - Jakarta Barat 11530, Indonesia Flat no.3B, Urmilla House
Tel: +62 21 5367 8278 #15, ARK Colony, Eldams Road
Fax: +62 21 5366 0688 Chennai-600 018, India
E-mail: info.indonesia@belimo.ch Tel: +91 44 24355154/5153
E-mail: info.india@belimo.ch

89
Innovation, Quality
and Consultancy:
Fire &
Smoke A partnership for
motorising HVAC
actuators
Damper

PICCV
EPIV
EV

CCV

Butterfly
Valve
93010-00171

Globe
Valve

Belimo regional head offices

EU BELIMO Automation AG AP Belimo Actuators Ltd. US BELIMO Aircontrol (USA), Inc. Or contact your nearest Sales Representative
Brunnenbachstrasse 1 Room 1601-6, 16/F, New Commerce Centre 33 Turner Road
8340 Hinwil, Switzerland 19 On Sum Street, Shatin, N.T., Hong Kong Danbury, CT 06810
Tel: +41 43 843 61 11 Tel: +852 2687 1716 USA
Fax: +41 43 843 62 68 Fax: +852 2687 1795 Tel: +800 543-9038 / 203 791-9915
E-mail: info@belimo.ch E-mail: info.asiapacific@belimo.ch Fax: +800 228-8283 / 203 791-9919 www.belimo.com