1 Rafter : Horizontal member at the ridge spanning the column

Span 4m
Spacing-Y 5.5 m
Load 1.5 KN/m2
Total Load 12.375 KN/m
Moment 24.75 KN-m (Maximum negative Moment at the continuous support)
Moment 13.922 KN-m (Maximum positive moment at the end support)
Allowable stress, σ 180 Mpa
maximum Zxx 137.5 cm3
Selected section ISMB 175
Available Z 145.4 cm3

2 Purlins: members spanning the rafter and the lintel beam


Spacing-X 1.3 m
Span 5.5 m
Load 1.5 KN/m2
Total Load 2.925 KN/m
Moment 11.06 KN-m (Maximum positive Moment at the center assuming simply supported)
Allowable stress, σ 185 Mpa
maximum Zxx 59.785 cm3
Selected section 140x80x4
Available Z 61.37 cm3

3 Secondary Purlins
Span 1.3 m
Spacing-Y 1.5 m
Load 1.5 KN/m2
Total Load 2.25 KN/m
Moment 0.48 KN-m (Maximum positive Moment at the center assuming simply supported)
Allowable stress, σ 165 Mpa
maximum Zxx 2.881 cm3
Selected section 38x38x2.6
Available Z 3 cm3