Professional Documents
Culture Documents
2.1.3 Tx LINEAR OUTPUT POWER (Plin) 53.50 dBm 53 PASS Set Gain 76 dB , Temp +23 C
@ 13.250 GHz
3.1.0 Tx CONVERSION GAIN AT
SMALL SIGNAL FOR 76 dB GAIN
SET (Pin = -30 dBm)
3.1.1 Tx CONVERSION GAIN AT 76 dB PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +23 C
SET @ 12.750 GHz
3.1.2 Tx CONVERSION GAIN AT 76.10 dB 75.50 76.50 PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +23 C
SET @ 13.000 GHz
3.1.3 Tx CONVERSION GAIN AT 76.80 dB PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +23 C
SET @ 13.250 GHz
3.4.0 Tx GAIN FLATNESS AND SLOPE
(AT Pin = -30 dBm AND GAIN SET
AT 76 dB)
3.4.1 Tx GAIN FLATNESS OVER THE 1.80 dB p-p 4 PASS Input Power -30 dBm , Set Gain 76.0 dB ,
ENTIRE FREQUENCY BAND Temp +23 C
3.4.2 Tx GAIN SLOPE (WORST CASE) 0.13 dB 0.30 PASS Input Power -30 dBm , Set Gain 76.0 dB ,
OVER ANY 10 MHz BAND Temp +23 C
4.1.0 INPUT AND OUTPUT RETURN
LOSS
4.1.1 TX INPUT WORST CASE RETURN 23 dB: 950 MHz 17 PASS Temp +23 C
LOSS (with Power On). Record
Frequency in band 950 - 1450
MHz
4.1.2 SSPA WG OUTPUT WORST 20.90 dB: 13.05 GHz 20 PASS Temp +23 C
CASE RETURN LOSS (with
Power Off). Record Frequency in
band 12.750 - 13.250 GHz
5.1.1 Tx OUT OF BAND SIGNAL -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
RELATED SPURIOUS. MEASURE Temp +23 C
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BANDS 11.700 - 12.750 GHz
AND 13.250 - 13.750 GHz
5.1.2 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +23 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 12.750 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
5.1.3 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +23 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.000 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
5.1.4 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +23 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.250 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
5.2.1 Tx OUT OF BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +23 C
RELATED SURIOUS. MEASURE
LARGEST SPURIOUS
AMPLITUDINE AND RECORD
FREQUENCY IN BANDS 11.700 -
12.750 GHz AND 13.250 - 13.750
GHz
5.2.2 Tx OUT OF BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +23 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BANDS 11.700 -
12.750 GHz AND 13.250 - 13.750
GHz
5.2.3 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +23 C
RELATED SPURIOUS. MEASURE
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BAND 12.750 - 13.250 GHz
5.2.4 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +23 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BAND 12.750 -
13.250 GHz
6.1.2 Tx NOISE POWER DENSITY AT -145 dBm/Hz -145 PASS Set Gain 76 dB , Temp +23 C
MAXIMUM GAIN SET, WITHOUT
INPUT SIGNAL, IN Rx BAND @
11.700 GHz
8.1.0 Tx PHASE NOISE (CW = 13.000
GHz)
8.1.1 Tx PHASE NOISE @ 100 Hz -72.30 dBc/Hz -65 PASS Temp +23 C
OFFSET FROM CARRIER @
13.000 GHz
8.1.2 Tx PHASE NOISE @ 1 kHz -80.30 dBc/Hz -75 PASS Temp +23 C
OFFSET FROM CARRIER @
13.000 GHz
8.1.3 Tx PHASE NOISE @ 10 kHz -89.30 dBc/Hz -85 PASS Temp +23 C
OFFSET FROM CARRIER @
13.000 GHz
8.1.4 Tx PHASE NOISE @ 100 kHz -112 dBc/Hz -95 PASS Temp +23 C
OFFSET FROM CARRIER @
13.000 GHz
9.1.0 INTEGRATED PHASE NOISE AT
RATED Plin
9.1.1 INTEGRATED PHASE NOISE AT 0.76 DEG/RMS 2 PASS Temp +23 C
Plin
10.0.0 POWER CALIBRATION
10.1.0 RF OUTPUT MONITOR PORT
COUPLING RATIO
10.1.1 RF OUTPUT MONITOR PORT 50.41 dB 48 52 PASS Temp +23 C
COUPLING RATIO @ 12.750 GHz
10.1.2 RF OUTPUT MONITOR PORT 50.57 dB 48 52 PASS Temp +23 C
COUPLING RATIO @ 12.800 GHz
10.1.3 RF OUTPUT MONITOR PORT 50.65 dB 48 52 PASS Temp +23 C
COUPLING RATIO @ 12.850 GHz
10.1.4 RF OUTPUT MONITOR PORT 50.63 dB 48 52 PASS Temp +23 C
COUPLING RATIO @ 12.900 GHz
10.1.5 RF OUTPUT MONITOR PORT 50.40 dB 48 52 PASS Temp +23 C
COUPLING RATIO @ 12.950 GHz
Page 6 of 19
18.1.1 Tx LINEAR OUTPUT POWER (Plin) 53.10 dBm 53 PASS Set Gain 76 dB , Temp +55 C
@ 12.750 GHz
18.1.2 Tx LINEAR OUTPUT POWER (Plin) 54.30 dBm 53 PASS Set Gain 76 dB , Temp +55 C
@ 13.000 GHz
18.1.3 Tx LINEAR OUTPUT POWER (Plin) 53.30 dBm 53 PASS Set Gain 76 dB , Temp +55 C
@ 13.250 GHz
19.1.0 Tx CONVERSION GAIN AT
SMALL SIGNAL FOR 76 dB GAIN
SET (Pin = -30 dBm) AT
ELEVATED TEMPERATURE
19.1.1 Tx CONVERSION GAIN AT 76.80 dB PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +55 C
SET @ 12.750 GHz
19.1.2 Tx CONVERSION GAIN AT 77.50 dB PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +55 C
SET @ 13.000 GHz
19.1.3 Tx CONVERSION GAIN AT 78.50 dB PASS Input Power -30 dBm , Set Gain 76 dB ,
SMALL SIGNAL FOR 76 dB GAIN Temp +55 C
SET @ 13.250 GHz
19.4.0 Tx GAIN FLATNESS AND SLOPE
(AT Pin = -30 dBm AND GAIN SET
AT 76 dB) AT ELEVATED
TEMPERATURE
19.4.1 Tx GAIN FLATNESS OVER THE 2.40 dB p-p 4 PASS Input Power -30 dBm , Set Gain 76 dB ,
ENTIRE FREQUENCY BAND Temp +55 C
19.4.2 Tx GAIN SLOPE (WORST CASE) 0.13 dB 0.30 PASS Input Power -30 dBm , Set Gain 76 dB ,
OVER ANY 10 MHz BAND Temp +55 C
20.1.0 Tx SPURIOUS AT SATURATED
POWER AT ELEVATED
TEMPERATURE
20.1.1 Tx OUT OF BAND SIGNAL -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
RELATED SPURIOUS. MEASURE Temp +55 C
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BANDS 11.700 - 12.750 GHz
AND 13.250 - 13.750 GHz
Page 12 of 19
20.1.2 Tx IIN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +55 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 12.750 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
20.1.3 Tx IIN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +55 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.000 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
20.1.4 Tx IIN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp +55 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.250 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
20.2.2 Tx OUT OF BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +55 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BANDS 11.700 -
12.750 GHz AND 13.250 - 13.750
GHz
20.2.3 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +55 C
RELATED SPURIOUS. MEASURE
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BAND 12.750 - 13.250 GHz
20.2.4 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp +55 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BAND 12.750 -
13.250 GHz
23.1.2 Tx PHASE NOISE @ 1 kHz -80.80 dBc/Hz -75 PASS Temp +55 C
OFFSET FROM CARRIER @
13.000 GHz
23.1.3 Tx PHASE NOISE @ 10 kHz -86.80 dBc/Hz -85 PASS Temp +55 C
OFFSET FROM CARRIER @
13.000 GHz
23.1.4 Tx PHASE NOISE @ 100 kHz -111.20 dBc/Hz -95 PASS Temp +55 C
OFFSET FROM CARRIER @
13.000 GHz
24.1.0 MAXIMUM DC CURRENT
CONSUMPTION AT ELEVATED
TEMPERATURE
24.1.1 12 V DC POWER SUPPLY 139.90 PASS Temp +55 C
CURRENT CONSUMPTION (DC)
AT 56 dBm OUTPUT POWER
24.1.2 25 V DC POWER SUPPLY 65.70 PASS Temp +55 C
CURRENT CONSUMPTION (DC)
AT 56 dBm OUTPUT POWER
25.1.0 COLD START-UP
25.1.1 STORE THE UNPOWERED UNIT PASS Temp -30 C
UNDER TEST (UUT) AT A
TEMPERATURE OF -30 C FOR A
MINIMUM AN HOUR.
WITHOUT CHANGING
TEMPERATURE VERIFY THAT
THE UUT STARTS NORMALLY
AFTER COLD STORAGE.
26.1.0 Tx SATURATED OUTPUT POWER
(Psat) @ 3 dB COMPRESSION
AND MAXIMUM Tx GAIN SET (76
dB) AT LOW TEMPERATURE
26.1.1 Tx SATURATED OUTPUT POWER 56.60 dBm 55 PASS Set Gain 76 dB , Temp -30 C
(Psat) AT 3 dB COMPRESSION @
12.750 GHz (56 dBm typical)
26.1.2 Tx SATURATED OUTPUT POWER 56.70 dBm 55 PASS Set Gain 76 dB , Temp -30 C
(Psat) AT 3 dB COMPRESSION @
13.000 GHz(56 dBm typical)
Page 15 of 19
26.1.3 Tx SATURATED OUTPUT POWER 56 dBm 55 PASS Set Gain 76 dB , Temp -30 C
(Psat) AT 3 dB COMPRESSION @
13.250 GHz(56 dBm typical)
27.1.0 Tx LINEAR OUTPUT POWER (Plin)
@ MAXIMUM Tx GAIN SET (76
dB) AT LOW TEMPERATURE
28.4.1 Tx GAIN FLATNESS OVER THE 0.73 dB p-p 4 PASS Input Power -30 dBm , Set Gain 76 dB ,
ENTIRE FREQUENCY BAND Temp -30 C
28.4.2 Tx GAIN SLOPE (WORST CASE) 0.14 dB 0.30 PASS Input Power -30 dBm , Set Gain 76 dB ,
OVER ANY 10 MHz BAND Temp -30 C
29.1.0 Tx SPURIOUS AT SATURATED
POWER AT LOW TEMPERATURE
29.1.1 Tx OUT OF BAND SIGNAL -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
RELATED SPURIOUS. MEASURE Temp -30 C
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BANDS 11.700 - 12.750 GHz
AND 13.250 - 13.750 GHz
29.1.2 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp -30 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 12.750 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
29.1.3 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp -30 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.000 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
29.1.4 Tx IN-BAND SIGNAL RELATED -65 dBc -60 PASS Input Power -20 dBm , Set Gain 76 dB ,
SPURIOUS. MEASURE LARGEST Temp -30 C
SPURIOUS AMPLITUDE FOR CW
FREQUENCYF0 = 13.250 GHz
AND RECORD SPURIOUS
FREQUENCY IN BAND 12.750 -
13.250 GHz
Page 17 of 19
29.2.2 Tx OUT OF BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp -30 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BANDS 11.700 -
12.750 GHz AND 13.250 - 13.750
GHz
29.2.3 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp -30 C
RELATED SPURIOUS. MEASURE
LARGEST SPURIOUS AMPLITUDE
AND RECORD FREQUENCY IN
BAND 12.750 - 13.250 GHz
29.2.4 Tx IN-BAND NON-SIGNAL -20 dBm -5 PASS Set Gain 76 dB , Temp -30 C
RELATED SPURIOUS. MEASURE
NEXT TO LARGEST SPURIOUS
AMPLITUDE AND RECORD
FREQUENCY IN BAND 12.750 -
13.250 GHz
30.1.1 Tx IN BAND NOISE POWER -77.90 dBm/Hz -70 PASS Set Gain 76 dB , Temp -30 C
DENSITY AT MAXIMUM GAIN
SET, WITHOUT INPUT SIGNAL
30.1.2 Tx NOISE POWER DENSITY AT -145 dBm/Hz -145 PASS Set Gain 76 dB , Temp -30 C
MAXIMUM GAIN SET, WITHOUT
INPUT SIGNAL, IN Rx BAND @
11.700 GHz
32.1.0 Tx PHASE NOISE (CW = 13.000
GHz) AT LOW TEMPERATURE
32.1.1 Tx PHASE NOISE @ 100 Hz -73.60 dBc/Hz -65 PASS Temp -30 C
OFFSET FROM CARRIER @
13.000 GHz
32.1.2 Tx PHASE NOISE @ 1 kHz -83 dBc/Hz -75 PASS Temp -30 C
OFFSET FROM CARRIER @
13.000 GHz
32.1.3 Tx PHASE NOISE @ 10 kHz -92 dBc/Hz -85 PASS Temp -30 C
OFFSET FROM CARRIER @
13.000 GHz
32.1.4 Tx PHASE NOISE @ 100 kHz -112.30 dBc/Hz -95 PASS Temp -30 C
OFFSET FROM CARRIER @
13.000 GHz
33.1.0 MAXIMUM DC CURRENT
CONSUMPTION AT LOW
TEMPERATURE
33.1.1 12 V DC POWER SUPPLY 134.90 PASS Temp -30 C
CURRENT CONSUMPTION (DC)
AT 56 dBm OUTPUT POWER
33.1.2 25 V DC POWER SUPPLY 62.30 PASS Temp -30 C
CURRENT CONSUMPTION (DC)
AT 56 dBm OUTPUT POWER
34.1.0 MAXIMUM GAIN VARIATION
OVER TEMPERATURE
34.1.1 Determine Maximum Gain 0.80 dBp-to-p 3 PASS Input Power -30 dBm , Set Gain 76 dB
Variation for 76.0 dB Gain over
Temperature at 12.750 GHz
Page 19 of 19
34.1.2 Determine Maximum Gain 1.70 dBp-to-p 3 PASS Input Power -30 dBm , Set Gain 76 dB
Variation for 76.0 dB Gain over
Temperature at 13.000 GHz
34.1.3 Determine Maximum Gain 2.70 dBp-to-p 3 PASS Input Power -30 dBm , Set Gain 76 dB
Variation for 76.0 dB Gain over
Temperature at 13.250 GHz
35.0.0 Redundancy Operation
35.0.1 Verify Tx 1:1 Redundancy PASS Temp +23 C
Operation with Transceiver
Emulator. Switch from A to B.
Confirm Tx states indicated
correctly and switch is
successful.
35.0.2 Verify Tx 1:1 Redundancy PASS Temp +23 C
Operation with Transceiver
Emulator. Switch from B to A.
Confirm Tx states indicated
correctly and switch is
successful.