NCR SelfServ™ 87 ATM Site Preparation

B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide

The product described in this document is a licensed product of NCR 
Corporation. 
NCR, NCR SelfServ and APTRA are trademarks of NCR Corporation. Other 
product names mentioned in this publication may be trademarks or registered 
trademarks of their respective companies and are hereby acknowledged.
Where creation of derivative works, modifications or copies of this NCR 
copyrighted documentation is permitted under the terms and conditions of an 
agreement you have with NCR, NCR's copyright notice must be included.
It is the policy of NCR Corporation (NCR) to improve products as new 
technology, components, software, and firmware become available. NCR, 
therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed 
by NCR in all parts of the world. In some instances, photographs are of 
equipment prototypes. Therefore, before using this document, consult with 
your NCR representative or NCR office for information that is applicable and 
current.

NCR Proprietary Information ‐ not to be disclosed or reproduced without 
written consent.

© 2015–2018
by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com. 
All Rights Reserved
  B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Contents i
Extreme Power On Range (Up To One Hour) .................................. 5 ‐ 2 Servicing Areas ‐ Minimum .................................................................. 9 ‐ 7
Introduction Barometric Pressure ............................................................................. 5 ‐ 2 Single ATM ...................................................................................... 9 ‐ 7
Audience ...............................................................................................1 ‐ 1 Side By Side ..................................................................................... 9 ‐ 7
About This Document ...........................................................................1 ‐ 1 Clearances ‐ Top Box Opening.............................................................. 9 ‐ 8
Revision Record ....................................................................................1 ‐ 1 Power Requirements Clearances ‐ Corridor............................................................................ 9 ‐ 8
AC Power Requirements....................................................................... 6 ‐ 1 Clearances ‐ Exterior Wall .................................................................... 9 ‐ 8
Input Voltage ........................................................................................ 6 ‐ 1 Standard Collar................................................................................ 9 ‐ 8
Customer Responsibilities Grounding............................................................................................. 6 ‐ 1 Advert Collar ................................................................................... 9 ‐ 8
Notice ...................................................................................................2 ‐ 1 Transient Protection............................................................................. 6 ‐ 1
Site Compliance ....................................................................................2 ‐ 1
Customer Actions .................................................................................2 ‐ 1 Variant Details ‐ Short Sleeve
Cable Requirements Package Dimensions........................................................................... 10 ‐ 1
Cable Preparation................................................................................. 7 ‐ 1 ATM Dimensions ................................................................................ 10 ‐ 1
Standards Compliance Data Line Transient Protection............................................................. 7 ‐ 1 Collar Dimensions............................................................................... 10 ‐ 1
Radio Frequency Interference ..............................................................3 ‐ 1 Standard ........................................................................................ 10 ‐ 1
RS‐232 Cable (9 pin) ............................................................................. 7 ‐ 1
FCC Radio Frequency Interference Statement ................................3 ‐ 1 Advert............................................................................................ 10 ‐ 1
Alarm Interface Cables ......................................................................... 7 ‐ 2
Canadian Class A Device Declaration...............................................3 ‐ 1
Basic Alarm Cable ............................................................................ 7 ‐ 2 Weight and Floor Loading .................................................................. 10 ‐ 2
Safety ....................................................................................................3 ‐ 1 Enhanced Alarm Cable .................................................................... 7 ‐ 2 Standard Security Enclosures........................................................ 10 ‐ 2
Safety Directive................................................................................3 ‐ 1 Gas and Solid Explosion Resistant (EX GAS) Security Enclosures .. 10 ‐ 2
Ethernet Standard Cable ...................................................................... 7 ‐ 3
Harmonised Safety Standard...........................................................3 ‐ 1
Power Cable.......................................................................................... 7 ‐ 3 Security Bolts...................................................................................... 10 ‐ 3
Electromagnetic Compatibility (EMC)...................................................3 ‐ 1
Bolt Holes ........................................................................................... 10 ‐ 3
Immunity Standards ........................................................................3 ‐ 1
EU EMC Directive 2014/30/EU ........................................................3 ‐ 1 Cable Entry ......................................................................................... 10 ‐ 3
Decals Hole in the Wall.................................................................................. 10 ‐ 4
Emission Standards..........................................................................3 ‐ 1
Decal Design And Material ................................................................... 8 ‐ 1 Hole at Optimum Height ............................................................... 10 ‐ 4
Additional Requirements for 220V ‐ 240V Units .............................3 ‐ 1
Suggested Designs ................................................................................ 8 ‐ 1 Facia Items ......................................................................................... 10 ‐ 5
Accessibility ..........................................................................................3 ‐ 1
Card Reader..................................................................................... 8 ‐ 1 Topmost Viewable Facia Item ....................................................... 10 ‐ 5
Highest Operable Point ...................................................................3 ‐ 1
Device Identification Decals ............................................................ 8 ‐ 1 Heights and Depths ....................................................................... 10 ‐ 5
Decal Placement ................................................................................... 8 ‐ 1 Distance for Voice Guidance ......................................................... 10 ‐ 5
Product Overview Advert Panel ......................................................................................... 8 ‐ 1 Servicing Areas ‐ Optimum................................................................. 10 ‐ 6
General Description ..............................................................................4 ‐ 1 Single ATM .................................................................................... 10 ‐ 6
Options ............................................................................................4 ‐ 1 Side By Side ................................................................................... 10 ‐ 6
Variant Details ‐ Slim Sleeve Servicing Areas ‐ Minimum ................................................................ 10 ‐ 7
Acoustics...............................................................................................4 ‐ 1
Package Dimensions ............................................................................. 9 ‐ 1 Single ATM .................................................................................... 10 ‐ 7
Heat Dissipation....................................................................................4 ‐ 1
ATM Dimensions................................................................................... 9 ‐ 1 Side By Side ................................................................................... 10 ‐ 7
Product Identification...........................................................................4 ‐ 1
Collar Dimensions................................................................................. 9 ‐ 1 Clearances ‐ Top Box Opening............................................................ 10 ‐ 8
Standard .......................................................................................... 9 ‐ 1 Clearances ‐ Corridor.......................................................................... 10 ‐ 8
Site Requirements Advert.............................................................................................. 9 ‐ 1 Clearances ‐ Exterior Wall .................................................................. 10 ‐ 8
Positioning the ATM .............................................................................5 ‐ 1 Weight and Floor Loading .................................................................... 9 ‐ 2 Standard Collar.............................................................................. 10 ‐ 8
Floor......................................................................................................5 ‐ 1 Standard Security Enclosures .......................................................... 9 ‐ 2 Advert Collar ................................................................................. 10 ‐ 8
Gas and Solid Explosion Resistant (EX GAS) Security Enclosures .... 9 ‐ 2
Doorways and Corridors .......................................................................5 ‐ 1
Security Bolts........................................................................................ 9 ‐ 3
Wall.......................................................................................................5 ‐ 1
Bolt Holes ............................................................................................. 9 ‐ 3 Variant Details ‐ Standard Sleeve
Wall Cavity.......................................................................................5 ‐ 1
Installing Through a Glass Wall........................................................5 ‐ 1 Cable Entry ........................................................................................... 9 ‐ 3 Package Dimensions........................................................................... 11 ‐ 1
Collar Tolerance...............................................................................5 ‐ 1 Hole in the Wall .................................................................................... 9 ‐ 4 ATM Dimensions ................................................................................ 11 ‐ 1
Ambient Lighting...................................................................................5 ‐ 2 Hole at Optimum Height ................................................................. 9 ‐ 4 Collar Dimensions............................................................................... 11 ‐ 1
Task Lighting .........................................................................................5 ‐ 2 Facia Items............................................................................................ 9 ‐ 5 Standard ........................................................................................ 11 ‐ 1
Topmost Viewable Facia Item ......................................................... 9 ‐ 5 Advert............................................................................................ 11 ‐ 1
Temperature and Humidity ..................................................................5 ‐ 2
Normal Operating Range (Interior Environment)............................5 ‐ 2 Heights and Depths ......................................................................... 9 ‐ 5 Weight and Floor Loading .................................................................. 11 ‐ 2
Normal Operating Range (Exterior Environment) ...........................5 ‐ 2 Distance for Voice Guidance ........................................................... 9 ‐ 5 Standard Security Enclosures........................................................ 11 ‐ 2
Storage Range (Up To Three Months) .............................................5 ‐ 2 Servicing Areas ‐ Optimum ................................................................... 9 ‐ 6 Gas and Solid Explosion Resistant (EX GAS) Security Enclosures .. 11 ‐ 2
Transit Range (Up To One Week) ....................................................5 ‐ 2 Single ATM....................................................................................... 9 ‐ 6 Security Bolts...................................................................................... 11 ‐ 3
Side By Side ..................................................................................... 9 ‐ 6
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Contents ii
Bolt Holes............................................................................................11 ‐ 3
Cable Entry..........................................................................................11 ‐ 3
Hole in the Wall ..................................................................................11 ‐ 4
Hole at Optimum Height ...............................................................11 ‐ 4
Facia Items..........................................................................................11 ‐ 5
Topmost Viewable Facia Item .......................................................11 ‐ 5
Heights and Depths .......................................................................11 ‐ 5
Distance for Voice Guidance .........................................................11 ‐ 5
Servicing Areas ‐ Optimum .................................................................11 ‐ 6
Single ATM.....................................................................................11 ‐ 6
Side By Side....................................................................................11 ‐ 6
Servicing Areas ‐ Minimum.................................................................11 ‐ 7
Single ATM.....................................................................................11 ‐ 7
Side By Side....................................................................................11 ‐ 7
Clearances ‐ Top Box Opening ............................................................11 ‐ 8
Clearances ‐ Corridor ..........................................................................11 ‐ 8
Clearances ‐ Exterior Wall...................................................................11 ‐ 8
Standard Collar ..............................................................................11 ‐ 8
Advert Collar..................................................................................11 ‐ 8

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Introduction 1 ‐ 1
AUDIENCE ABOUT THIS DOCUMENT REVISION RECORD
This document is intended for architects and those responsible for preparing a  This site preparation document is designed to be read on wide aspect ratio 
Date Revision Pages Reason for Change
site prior to the arrival of the ATM. screens. Each section has been structured to fit the maximum amount of 
information on the minimum number of pages yet still be readable when  May 2015 A All New publication
printed on A3 size paper. Printing on smaller paper sizes may reduce readability  September 2015 B 9-1, 10-1 Update ATM, Package,and Collar Dimensions sections.
Add cable entry cover in ATM Dimension section.
but will make handling easier.
January 2017 C 4-1, 10-2, Added CEN III, CEN III EX GAS, CEN IV EX GAS safe
The document is organised into sections covering the following topics: 11-2 variants
8-1 Added Advert Panel Measurements
 Introduction ‐ this section 9-1 to 9-7 Added Slim Sleeve Variant
 Customer Responsibilities September 2017 D 11-1 Correction to sleeve dimension illustration.
 Standards Compliance August 2018 E Title Company address change
9-1, 10-1, 11-1 Dimension updates
 Product Overview 2-1 Bulletin added regarding sealant
 Site Requirements
 Power Requirements
 Cable Requirements
 Decals
 Variant Details ‐ Short Sleeve
 Variant Details ‐ Standard Sleeve
Each page has two or three columns laid out as follows:
Publication name Section name Section number Page number

Column 1 Column 2 Column 3

Copyright Publication ID

Where left and right side are stated the ATM is viewed from the front (facia 
side) of the ATM. All plan views are top down unless otherwise stated.
Unless otherwise stated all dimensions are rounded to the nearest millimetre 
and equivalent decimal of an inch.

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Customer Responsibilities 2 ‐ 1
NOTICE SITE COMPLIANCE CUSTOMER ACTIONS
This is a contractual document. It contains important warnings and confers  This document contains the information necessary for the preparation of a site  The customer must do or provide the following:
important legal rights and obligations. You are advised to read it carefully. conforming to NCR specifications. It is very important that the site complies 
 When required by NCR, provide the NCR customer service 
with the requirements specified in this document, because, once the 
It is the responsibility of you, the customer, to assure that all installation  representative with appropriate drawings that indicate: 
equipment has been installed, deficiencies in site preparation or the problems 
preparations are complete and in compliance with all specifications and   Location of the equipment
caused by these deficiencies are much more difficult to detect and correct.
requirements of NCR and all applicable national, state, or local codes,   Site wiring (power and signal, paths and lengths) 
regulations and laws. Further, failure to comply with these requirements or to take proper steps to 
 Location of other equipment capable of generating electrical noise, 
protect equipment against risks identified in this document may cause serious 
This equipment must be installed and used in strict accordance with the  electromagnetic interference, heat, etc.
damage to the equipment and to the customer’s business.
manufacturer’s instructions. However, there is no guarantee that interference   Make building alterations necessary to meet wiring and other site 
to radio communications will not occur in a particular commercial installation. If  In addition to the need to comply with the requirements specified, electrical  requirements.
this equipment does cause interference, which can be determined by turning  wiring and mechanical systems must also comply with all relevant codes, laws   Provide and install all communications cables, wall jacks, special 
the equipment off and on, the user is encouraged to consult an NCR service  and regulations. connectors, and associated hardware.
representative immediately.
It is important that the site be prepared by a customer or his agent who is fully   Provide and install necessary power distribution boxes, conduits, 
conversant with the special requirements of electronic equipment. The  grounds, lightning protection, and associated hardware.
responsibility for ensuring that the site is prepared in compliance with this   Make sure all applicable codes, regulations and laws (including, but not 
CAUTION NCR Corporation is not responsible for any radio or television  document remains with the customer. limited to, electrical, building, safety, and health) are met.
interference caused by unauthorized modifications of this  For information and guidance purposes only, a list is provided, in general terms,   Provide and install auxiliary power or other equipment as required.
equipment or the substitution or attachment of connecting cables  of those matters for which the customer is responsible. This list is not intended   Provide storage or service areas as required.
and equipment other than those specified by NCR. Such  to be comprehensive, and in no way modifies, alters, or limits the responsibility   Make sure the environmental requirements of the system/unit are met.
unauthorized modifications, substitutions, or attachments may  of the customer for all aspects of adequate site preparation.
void the user’s authority to operate the equipment. The correction   Provide floor coverings and environmental systems that limit or control 
of interference caused by such unauthorized modifications,  NCR staff will be available to answer questions relating to the contents of this  static electricity build‐up and discharge.
substitutions, or attachments will be the responsibility of the user. document but, except where:  Install the product at a height which meets the accessibility regulations 
of the relevant country.
a. the customer has been notified that a full or partial consultancy service 
is available and/or that NCR will be willing to undertake a preliminary or   Ensure that any cladding, such as wallboards, are watertight and sealed 
final site survey and with an appropriate sealant where it meets both the wall and the ATM, 
to avoid water ingress to the ATM and surround. The sealant should be 
b. the customer shall have entered into a formal contract with NCR for 
a low modulus, one‐part silicone sealant suitable for both porous and 
provision of the same
non‐porous surfaces. It should conform to ISO 11600‐25LM and also 
no comment, suggestion or advice offered or not offered about preparation of  meet ISO specification 9047 class 50.
the site nor any inspection of the site whether before or after preparation is to 
be taken as approval of the location of the site and equipment or of its 
preparation and NCR will not be liable in respect of any comment, suggestion or 
advice given by its staff or in respect of any failure to give advice.
Finally, only the customer can know the full extent of damage which may be 
caused to his business by reason of failure of the equipment which is to be 
installed. For this reason it is the customer’s responsibility to ascertain the 
extent of any such possible damage to his existing or planned business, and to 
effect, full insurance in respect of it.

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Standards Compliance 3 ‐ 1
RADIO FREQUENCY INTERFERENCE ELECTROMAGNETIC COMPATIBILITY (EMC) ACCESSIBILITY
It is the responsibility of the owning institution to ensure that the heights from 
FCC Radio Frequency Interference Statement Immunity Standards the sidewalk level to the facia items comply with any local regulations.
This equipment has been tested and found to comply with the limits for a Class  The ATM complies with the following requirements for radiated and conducted 
A digital device, pursuant to Part 15 of the Federal Communications  immunity:  Highest Operable Point
Commission (FCC) Rules. These limits are designed to provide reasonable 
 EN 55024 The highest operable point (HOP) is the top of the touchscreen.
protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate  As per the requirements of EN55024 (2010), the ATM complies with the 
radio frequency energy and, if not installed and used in accordance with the  requirements of the following normative Immunity Standard: 
instruction manual, may cause harmful interference to radio communications.   EN 61000‐4‐2 Electrostatic Discharge
Operation of this equipment in a residential area is likely to cause harmful   EN 61000‐4‐3 Radiated RF
interference in which case you, the customer, will be required to correct the 
 EN 61000‐4‐4 Electrical Fast Transient/Burst
interference at your own expense.
 EN 61000‐4‐5 Surge
 EN 61000‐4‐6 Conducted RF
Canadian Class A Device Declaration  EN 61000‐4‐8 Power Frequency Magnetic Field
This digital apparatus does not exceed the Class A limits for radio noise   EN 61000‐4‐11 Voltage Dips/Short Interruption.
emissions from digital apparatus set out in the Radio Interference Regulations 
of the Canadian Department of Communications.
EU EMC Directive 2014/30/EU
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant 
les limites applicables aux appareils numériques de la classe A prescrites dans le  This equipment has been found to comply with the essential requirements of 
Réglement sur le brouillage radioélectrique édicté par le ministère des  EMC Directive 2014/30/EU, by testing to harmonized standards EN55032, 
Communications du Canada. EN55024, EN61000‐3‐2, and EN61000‐3. The equipment complies with the 
limits for a Class A digital device, pursuant to EN55032.
 Warning: This equipment is compliant with Class A of CISPR 32. In a 
SAFETY residential environment this equipment may cause radio interference.

Safety Directive Emission Standards
 2014/35/EU ‘Low Voltage Directive and Amendment’. The ATM complies with the following requirements for radiated and conducted 
emissions:

Harmonised Safety Standard  EN 55032 Class A
 FCC 47CFR Part 15. Class A
 EN 60950‐1: ‘Information Technology Equipment ‐ Safety’
 CISPR 22 Class A
 AS/NZS 3548 Class A
 GB 9254 Class A
 CNS 13438 Class A.

Additional Requirements for 220V ‐ 240V Units
The ATM complies with the following requirements for conducted emissions: 
 EN 61000‐3‐2: Mains harmonics, Class A
 EN 61000‐3‐3: Mains flicker.

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Product Overview 4 ‐ 1
GENERAL DESCRIPTION ACOUSTICS PRODUCT IDENTIFICATION
The NCR SelfServ 6687 is a ‘through the wall’ ATM which may be installed  For most variants the acoustics sound power does not exceed: The illustration below is typical of the layout of the product identification label 
through any suitable exterior wall or in a vestibule location.  which is fixed inside the ATM.
 65 dB(A) when idle
 68 dB(A) when operating.

NCR SelfServ™ 87
HEAT DISSIPATION NCR Global Solutions Ltd. Class: 6687 Model: 6687-XXXX-YYYY

The NCR SelfServ product range is a flexible hardware platform. NCR  Made in UK Tracer: XX - XX Serial: XX - XXXXXXXX


Manufactured: Xxxxxx XXXX Vãc: XXX - XXXv Hz: 50/60 A: X.X
recommends that actual power measurements are taken and used to establish 
the heat dissipation for specific hardware configurations. These measurements 
should include any custom or third party features.
Safety logos here
Where specific measurements are not available then, as a guide, 760 KJ/hour 
can be used as an indicative heating load. This figure is based on an ATM in idle 
mode, with a medium to high feature functionality configuration. Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
Heat dissipation figures are largely unaffected by transactional rates. (2) this device must accept any interference received, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le
ministère des Communications du Canada

Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J

The product is identified by a class and a 4 digit model number. The serial 
number is unique to each ATM. The tracer number is used to identify where the 
ATM was built. 
Please quote all of the serial and tracer numbers, including the prefix, when 
making reference to the ATM.
Options Electrical rating information is also shown on the product label.

Standard Security Enclosure
 CEN I

 CEN III

Gas and Solid Explosion Resistant (EX GAS) Security Enclosure
 CEN III

 CEN IV

Sleeve
 Slim Sleeve
 Short Sleeve
 Standard Sleeve

Collar
 Standard
 Advert

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Site Requirements 5 ‐ 1
POSITIONING THE ATM WALL Collar Tolerance
The ATM may be installed through any suitable exterior wall or vestibule  A 25 mm (1.0 in.) wide smooth surface is required around the edge of the wall  The collar has a tolerance of +/‐ 4 mm (0.16 in.) or +/‐ 0.5° at the top and 
location. opening to enable a good weather seal. bottom, with 0 mm (0.00 in.) or 0°at its centre. 

The ATM must be positioned away from heat sources or any air conditioning  The collar cannot accommodate large dips or depressions in the wall. Make 
equipment and within easy reach of power outlets. Wall Cavity sure the wall is smooth and even.

Bright lights or windows behind the user may degrade camera performance.  Any cavity in the wall must be sealed at installation time to provide a flush 
Position the ATM away from direct sunlight. surface that does not extend into the wall opening. Leave the gap between the 
Allow sufficient room for installation and servicing requirements. ATM sleeve and the wall opening clear to allow air at room temperature to 
circulate.

FLOOR Seal any cavity


Do not block air gaps
The ATM must be installed on a level, even, concrete or other noncombustible 
surface. In locations where the floor may be uneven, it is recommended that a 
steel plate is used under the ATM.
An antistatic floor covering should be used and must be of a type that will not 
generate dust or fluff. 
The ATM must be installed on a floor capable of supporting the maximum 
weight including media. Only the maximum weight should be considered as 
additional options may be added after installation. Floor loading is calculated by 
dividing the maximum weight of the ATM by the surface area of the ATM base 
in contact with the floor.
Service areas, ATM weights and floor loading can be found in the Variant Details 
section for your ATM.

DOORWAYS AND CORRIDORS
Make sure that doorways and corridors leading to your point of installation are 
wide enough to allow the package to pass through, or make arrangements to  Installing Through a Glass Wall
unpack the ATM and remove it from the pallet in an area with sufficient access  If you are installing your ATM through a glass wall you may require a suitable 
then move it to the installation site.  glass support (normally a steel collar) to sit between the ATM collar and the 
Make sure that any corridors can support the weight of the ATM, including all  glass. The requirement for this support should be determined by the architect. 
packaging and the pallet. If required, any such support should be sourced locally.
Corridor sizes and ATM weights can be found in the Variant Details section for 
your ATM.

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Site Requirements 5 ‐ 2
AMBIENT LIGHTING TEMPERATURE AND HUMIDITY  BAROMETRIC PRESSURE 
If the ATM is fitted with a camera, it is strongly recommended that there is a  Continuous operating at or near the range limits, or in a location where the   Operating/Transit Limits: 105 kPa (15.2 lbf/in2) to 70 kPa (10.2 lbf/in2) 
minimum of 50 lux lighting at floor level within the area illustrated below. temperature and humidity change beyond the specification, should be avoided.  Equivalent Altitude: Up to a maximum of 3000 m (9842.52 ft)
If installing though an exterior wall, the site must meet the requirements of 
both the Interior and Exterior environments.
Note: For exterior through the wall ATMs the humidity inside the building is 
restricted to a maximum of 30% at an outside temperature of 
‐35°C(‐31°F), with a linear relationship between temperature and 
humidity to a maximum humidity at 0°C (32°F).

Normal Operating Range (Interior Environment)
 Temperature: 0oC to 40oC (32oF to 104oF)
 Relative Humidity: 20% to 80%
 Dew Point Temperature Restriction: 26oC (79oF) maximum

Normal Operating Range (Exterior Environment)
 Temperature: ‐35oC to 50oC (‐31oF to 122oF)
1000 mm  Relative Humidity: 10% to 100%
(39.37 in.)  Dew Point Temperature Restriction: 26oC (79oF) maximum

Storage Range (Up To Three Months)
 Temperature: ‐10oC to 50oC (14oF to 122oF) 
1500 mm  Relative Humidity: 10% to 90%
(59.06 in.)

Transit Range (Up To One Week)
 Temperature: ‐40oC to 60oC (‐40oF to 140oF) 
TASK LIGHTING  Relative Humidity: 5% to 95%
A minimum of 200 lux is required for task lighting.
Extreme Power On Range (Up To One Hour)
 Temperature: 0oC to 45oC (32oF to 113oF) 
 Relative Humidity: 10% to 95%

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Power Requirements 6 ‐ 1
AC POWER REQUIREMENTS GROUNDING TRANSIENT PROTECTION
The maximum current requirements are: The ATM operates from a single phase, 3 wire supply: live, neutral and ground. In the process of power distribution, transient electrical energy (including, but 
not limited to, lightning strikes, intermittent short circuits, and switching 
 10A at 120V The ATM power requirements will normally permit it to operate within existing 
transients) can be introduced on to power lines. Such transient energy can be 
 4.5A at 230V. wiring configurations and from existing mains outlets provided that:
very damaging to electronic hardware and can also cause data corruption. 
The maximum inrush current is 100A.  the branch circuit of the distribution panel supporting the ATM is not  Under these circumstances, NCR recommends the use of AC power transient 
also used to support equipment with heavy inductive loads such as air  suppressors and data (communication) line transient suppressors. Such 
NCR does not recommend running an ATM with deposit devices without an  conditioners or AC motors. protective devices are intended to guard against power and data line transients 
Uninterruptible Power Supply (UPS). Without a UPS, there is the potential for 
 other branch circuits on the same distribution panel do not support  that can result in hardware damage and various system or program errors.
customer’s cash to be retained in the device if there is a power failure.
such equipment. Improvement of any deficiencies in power quality is a customer responsibility. 
 the installation meets or exceeds the regulatory and local guidelines  Malfunction and/or component failure as a result of power quality problems 
INPUT VOLTAGE with regard to electrical safety and all conductor sizing. are/is not covered by NCR Corporation Maintenance Agreement. NCR accepts 
The normal and safe operation of this ATM is dependant on the above. Only  no liability for any such occurrence nor for its consequences.
The ATM can operate from the following input mains voltages:
qualified personnel that meet local certification standards should be permitted  When power transient suppression is required, the suppressors used should 
 90V to 136V at 50/60Hz to ensure compliance. meet the following minimum requirements:
 180V to 264V at 50/60Hz. Note that the building ground point can also affect data integrity. For additional   Dissipate energy to match the appropriate application categories as 
information refer to Data Line Transient Protection in the Cable Requirements  defined by ANSI/IEEE Standard C62.41, Guide on Surge Voltages in Low‐
section. Voltage AC Power Circuits.
 Be of the voltage limiting (clipping), or tracking filter type. The 
suppressor must not ‘clamp’ the voltage to zero, and must self‐recover 
after the passage of the transient. The suppressor may be of the hybrid 
type construction that makes use of various technologies in order to 
meet speed and dissipation requirements.
 Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive 
indication of its failure such as a blown fuse or tripped breaker
 Be listed by the accepted safety organization for the country involved 
(e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, 
state, and national electrical codes and regulations.

Comparable to IEC
Location Category Transient
No 664 Category
Waveform Amplitudes
Volts = 1.2 x 50  s 6kV
Current = 8 x 20  s 3kA
B = Major feeders, short branch
III and
circuits, and load centres
0.5  Rise - 100 kHz 6kV
Ringwave 500A
C = Service Entrance and run to Volts = 1.2 x 50  s 10kV or more
IV
load centre Current = 8 x 20  s 10kA or more

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Cable Requirements 7 ‐ 1
CABLE PREPARATION RS‐232 CABLE (9 PIN)
NCR supply a power cable for the ATM. Other external cables are not supplied.  The ATM can have up to two RS‐232 (9 pin) outlets. The cable for each outlet 
Specifications for these cables are given in this section. should not exceed 12.24 m (40.16 ft) and must conform to the following 
specification:
It is the customer’s responsibility to have any required external cables installed 
1, 2 4
and to make sure that all cable preparations comply with NCR specifications as  3
well as with all national, state or local telephone and telegraph regulations and 
laws.
When producing cables allow for 2.2 m (7.22 ft) of cable within the ATM.

DATA LINE TRANSIENT PROTECTION 1. Connector, 9 way (NCR part no. 006-0010488).


2. Terminal wire, female (NCR part no. 009-0002640).
Voltage transients, line noise, surges, sags, impulses, and spikes may be  3. Cable, shielded multiconductor (NCR part no. 007-8907033).
experienced routinely or sporadically. When such phenomena occur the use of  4. Connector (determined by remote device).

protective devices may be required to ensure proper operation of the 
equipment. DCD
1
It is the responsibility of the customer to install and connect a data line  RXD
2
TXD
transient suppression system to correct or prevent any deficiencies. Such  3
DTR
systems must meet the following minimum requirements: 4
S-GND
5
DSR
 Be of the self‐recovering voltage limiting type. Exhibit a ‘short circuit’  6
RTS
mode upon its failure to ensure a positive indication of its failure. Insert  7
CTS
8
minimum inductive and capacity loading at the operating frequency. Be  RI
9
installed in accordance with all applicable local, state, and national 
electrical codes and regulations.
 Protect the data port from damage in the presence of a data line  Remove a 30 mm (1.18 in.) section of the outer sleeve, 2.2 m (7.22 ft.) from the 
transient event as defined in IEC Standard 1000‐4‐5 (formerly IEC 801‐ ATM end of the cable. 
5).
Take care not to cut through the cable shielding.
30 mm
(1.18 in.)

2.2 m
(7.22 ft.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Cable Requirements 7 ‐ 2
ALARM INTERFACE CABLES Basic Alarm Cable Enhanced Alarm Cable
The ATM may optionally be configured to provide an alarm interface which 
enables the ATM to be connected to an external local alarm system. The  1, 2, 5, 6 4 1, 2, 5, 6 4
interface may take the form of one of two options; a basic alarm system or an 
enhanced alarm system. 3 3

A stabilised, non‐interruptible power supply must be provided through the 
external alarm system. The alarm interface cable wiring must conform to the 
following specification:
 12V +/‐ 2V dc
 200mA maximum 1. Connector, 25 Way (NCR part no. 006-0005896) 1. Connector, 25 Way (NCR part no. 006-0005896)
 Ripple, 5% maximum. 2. Terminal, wire, female (NCR part no. 009-0002640) 2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed). 3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device). 4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038). 5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584). 6. Screw retainer (NCR part no. 601-0101584).

Chassis GND Chassis GND


1 1
Not connected Not connected
2 2
Not connected Test Transmitter A
3 3
Not connected Not connected
4 4
Not connected Tamper Alarm N.O.
5 5
Not connected Tamper Alarm N.C
6 6
Silent Alarm Common * Silent Alarm Common *
7 7
Door Alarm N.O. Door Alarm N.O.
8 8
Door Alarm N.C. Door Alarm N.C.
9 9
Vibration/Heat Common Composite Attack Common
10 10
Not connected Not connected
11 11
+12V +12V
12 12
Not connected Not connected
13 13
Not connected Not connected
14 14
Not connected Not connected
15 15
Not connected Test Transmitter B
16 16
Not connected Not connected
17 17
Not connected Tamper Alarm Common
18 18
Silent Alarm N.O. * Silent Alarm N.O. *
19 19
Silent Alarm N.C. * Silent Alarm N.C. *
20 20
Door Alarm Common Door Alarm Common
21 21
Vibration/Heat N.O. Composite Attack N.O.
22 22
Vibration/Heat N.C Composite Attack N.C
23 23
Not connected Not connected
24 24
+12V Return +12V Return
25 25

* Optional * Optional

Remove a 30 mm (1.18 in.) section of the outer sleeve, 85 mm (3.35 in.) from  Remove a 30 mm (1.18 in.) section of the outer sleeve, 85 mm (3.35 in.) from 
the ATM end of the cable.  the ATM end of the cable. 
Take care not to cut through the cable shielding. Take care not to cut through the cable shielding.
30 mm 30 mm
(1.18 in.) (1.18 in.)

85 mm 85 mm
(3.35 in.) (3.35 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Cable Requirements 7 ‐ 3
ETHERNET STANDARD CABLE POWER CABLE 
The ethernet standard cable must be fully shielded, 8 pin, category 5 compliant  The ATM is supplied either as a 120V or a 220‐240V unit. 120V ATMs are 
and must not exceed 97 m (318.20 ft) in length.  supplied with a power cable fitted with a NEMA type 5‐15P power source 
connector. 220‐240V ATMs are supplied with an unterminated power cable. 
Remove a 30 mm (1.18 in.) section of the outer sleeve, 1.8 m (5.91 ft.) from the 
Information about suitable power connectors is supplied with the accessories.
ATM end of the cable. 
The power cable supplied is 3 m (9.84 ft) in length. If it is necessary to increase 
Take care not to cut through the cable shielding.
this length to meet site requirements, then the extension must satisfy local or 
30 mm country regulations. 
(1.18 in.)

WARNING This equipment must be earthed.

1.8 m
(5.91ft.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Decals 8 ‐ 1
DECAL DESIGN AND MATERIAL DECAL PLACEMENT
Decals should be a maximum of 0.5 mm (0.02 in.) thick. NCR recommends they  NCR recommends placing entry/exit decals above or below the entry/exit slots, 
be made from textured polycarbonate with 3M 467 High Performance MP  determined by the space available near the slot.
adhesive.
Decals should provide good contrast, at least 70%, between foreground (text/ Receipt Cash
Dispense/Deposit
icon) and background.
A sans serif typeface should be used (Tiresias is recommended). The text size 
should be at least 14 point, and larger where possible. Where tactile decals are 
required they should be designed in line with specific country requirements.

SUGGESTED DESIGNS

Card Reader
53.5 mm
(2.10 in.)

85 mm
(3.35 in.)

1.5 mm Motorised DIP Skimming Protection


(0.06 in.) Solution
Radius in
four corners

Device Identification Decals

12 mm 70 mm
(0.47 in.) (2.76 in.)

Receipt Cash
Dispense/Deposit ADVERT PANEL

68 mm 2.5 mm 483 mm
(2.68 in.) (0.09 in.) (19.02 in.)
4 mm Radius in
(0.16 in.) four corners
Radius in
20 mm
four corners
(0.79 in.)
168 mm
(6.61 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 1
PACKAGE DIMENSIONS ATM DIMENSIONS COLLAR DIMENSIONS

Standard

597 mm 656 mm
(23.50 in.) (25.83 in.)

1146 mm
1858 mm (45.12 in.) 642 mm
(73.15 in.) (25.28 in.)
549 mm
(21.61 in.) 1101 mm
(43.35 in.)

1652 mm
610 mm (65.04 in.)
(24.02 in.)

466 mm 77 mm
24 mm
(18.35 in.) (3.03 in.)
120 mm 551 mm (0.94 in.)
(4.72 in.) (21.69 in.)
1527 mm
560 mm
(60.12 in.)
(22.05 in.)
800 mm 1031 mm 415 mm 86 mm 480 mm 86 mm 125 mm
(31.50 in.) (40.59 in.) (16.34 in.) (3.39 in.) (18.90 in.) (3.39 in.) (4.92 in.)
120 mm
(4.72 in.)
1612 mm
246 mm
(63.46 in.)
(9.69 in.)
Advert

508 mm 581 mm 630 mm 267 mm 656 mm 30 mm


(20.00 in.) (22.87 in.) (24.80 in.) (10.51 in.) (25.83 in.) (1.18 in.)
1533 mm
(60.35 in.)

28 mm 480 mm
128 mm 955 mm 63 mm
(1.10 in.) (18.90 in.)
(5.04 in.) (37.60 in.) (2.48 in.)
with optional 530 mm
extended (20.87 in.)
cable cover with optional UPS

1101 mm
1971 mm (43.35 in.)
1919 mm
(77.60 in.)
801 mm (75.55 in.)
(31.54 in.)

24 mm
551 mm (0.94 in.)
(21.69 in.)

120 mm
(4.72 in.) 86 mm 480 mm 86 mm 125 mm
(3.39 in.) (18.90 in.) (3.39 in.) (4.92 in.)
1527 mm
560 mm
(60.12 in.)
(22.05 in.)
800 mm
(31.50 in.)
120 mm
(4.72 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 2
WEIGHT AND FLOOR LOADING

Standard Security Enclosures

CEN I CEN III


635 kg 670 kg
Maximum weight
(1399.94 lb.) (1477.10 lb.)
1385 kg/m2 1462 kg/m2
Floor loading
(283.70 lb./ft2) (299.34 lb./ft2)

Gas and Solid Explosion Resistant (EX GAS) Security Enclosures

CEN III CEN IV


725 kg 775 kg
Maximum weight
(1598.35 lb.) (1708.58 lb.)
1582 kg/m2 1691 kg/m2
Floor loading
(323.91 lb./ft2) (346.25 lb./ft2)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 3
SECURITY BOLTS BOLT HOLES CABLE ENTRY
Bolts and anchors must be supplied by the owning organisation. The ATM must be bolted to the floor or plinth, through all the holes marked ‘A’,  480 mm
using four bolts with anchor washers. (18.9 in.)
To meet security standards the ATM must be bolted to the floor, through all of 
the bolt holes, using bolts with anchor washers as specified below. Bolts and  480 mm 265 mm 108 mm
anchor washers are to be supplied by the owning organisation. (18.9 in.) (10.43 in.) (4.25 in.)

Make sure that the floor or plinth is capable of withstanding the loading  265 mm 108 mm


imposed by the anchor points for these bolts. (10.43 in.) (4.25 in.)
149 mm
If an adjustable plinth is used, it must be bolted to the floor to the same  (5.87 in.)
specification as the ATM. 149 mm 149 mm
(5.87 in.) (5.87 in.)
The minimum specification for bolts and washers to secure the ATM to a 
A B A
concrete floor is:
 Bolts
 Type ‐ either resin anchor or shield anchor bolts 108 mm 410 mm
 Size ‐ M16 (5/8 in.) (4.25 in.) (16.14 in.)
 Minimum Length ‐ 150 mm (5.9 in.)  410 mm
(16.14 in.) 955 mm
 Strength ‐ high tensile (minimum ISO property class 8,8).
(37.6 in.)
 Washers 955 mm
 Type ‐ flat, steel (as per DIN7349 or equivalent) (37.6 in.)

 Size ‐ M16 (5/8 in.) 

 Outer diameter ‐ no greater than 40 mm (1.58 in.)
A A 296 mm
 Minimum thickness ‐ 6 mm (0.2 in.).
(11.65 in.)

65 mm 65 mm
(2.56 in.) (2.56 in.)
55 mm 55 mm
521 mm (2.17 in.) (2.17 in.)
(20.51 in.)

100 mm
Hole in the wall
(3.94 in.)

Centre-line
security enclosure
Hole A Bolt Holes Hole B (Alarm Hole)
21.5 mm 32.5 mm
(0.85 in.) (1.28 in.)

21 mm 25 mm
(0.83 in.) 40 mm (0.98 in.) 40 mm
(1.57 in.) (1.57 in.)

13 mm 14 mm
(0.51 in.) (0.55 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 4
HOLE IN THE WALL

Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from 
the sidewalk level to the facia items comply with any local regulations. Where 
no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height 
between the sidewalk and the interior floor. If there is no difference then the 
plinth must have the height specified in the illustrations below.
620 mm
(24.41 in.)

1069 mm
Hole in Wall
(42.09 in.)

750 mm 184 mm
(29.53 in.) (7.24 in.)
Security Enclosure

Sidewalk Plinth

100 mm (3.94 in.) View from Inside Building


Maximum

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 5
FACIA ITEMS Heights and Depths Distance for Voice Guidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
5
JKL
Touchscreen 1216 mm 366 mm 9 3 No. 5 Key
Top
381 mm (15.0 in.) (47.87 in.) (14.41 in.) 8
7 6 5
4

Display with FDKs 1140 mm 309 mm


Top FDK
381 mm (15 in.) (44.88 in.) (12.17 in.)
168 mm
Card Reader 2
963 mm 245 mm (6.61 in.)
Card Reader
(37.91 in.) (9.65 in.)
156 mm
Contactless Card Reader (behind Facia) 3
963 mm 245 mm (6.14 in.)
Receipt
S (37.91 in.) (9.65 in.)
183 mm
Private Audio 4
913 mm 205 mm (7.20 in.)
5
JKL
PIN Pad Number 5 key
(35.94 in.) (8.07 in.)
125 mm
S Cash Exit/Entry 6
909 mm 196 mm (4.92 in.)
Contactless Card Reader (behind Facia)
(35.79 in.) (7.72 in.)
265 mm
Barcode Reader 7
909 mm 196 mm (10.43 in.)
Biometric Reader
(35.79 in.) (7.72 in.)
111 mm
Biometric Reader 9
Topmost Viewable Facia Item 882 mm 138 mm (4.37 in.)
Private Audio
(34.72 in.) (5.43 in.)
The topmost viewable facia item is the 15 in. touchscreen. 125 mm
Receipt 10
838 mm 104 mm (4.92 in.)
S Cash Exit/Entry
(32.99 in.) (4.09 in.)
Display with FDKs Top Left 291 mm
11
616 mm 0 mm 381 mm (15 in.) FDK (11.46 in.)
Barcode Reader Activation Point
(24.25 in) (0 in.)
239 mm
Touchscreen Middle 12
(9.41 in.)
28°

381 mm (15 in.) Touchscreen

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 6
SERVICING AREAS ‐ OPTIMUM Side By Side
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks. Optimum Service Area

Wherever possible the ATM should be installed within the optimum servicing area.
2460 mm
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the  (96.85 in.)

minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area. 500 mm 480 mm 500 mm 480 mm 500 mm


(19.69 in.) (18.90 in.) (19.69 in.) (18.90 in.) (19.69 in.)
If you install in the minimum area then note that doors may open, and devices rack out, beyond the area shown. Always 
Width of
leave as much space as possible around the ATM to facilitate safe operation and servicing. Security
Enclosure 500 mm
(19.69 in.)

Single ATM

Optimum Service Area

500 mm 480 mm 500 mm


(19.69 in.) (18.90 in.) (19.69 in.) 1018 mm
(40.08 in.)
Width of
Security
Enclosure Rear of
2598 mm
(102.28 in.) Security Enclosure
(With Door Open)
500 mm
(19.69 in.)

1080 mm
(42.52 in.)

1018 mm
(40.08 in.)

Rear of
2598 mm
Security Enclosure Maximum
(102.28 in.)
(With Door Open) 100 mm
(3.94 in.) 750 mm
(29.53 in.)

1080 mm
(42.52 in.)

Maximum
100 mm
(3.94 in.) 750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 7
SERVICING AREAS ‐ MINIMUM Side By Side
This is the minimum area required for operating and servicing the ATM.
Common Minimum Service Area
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum  Additional areas, at least 1 required:
servicing area may increase the servicing and/or upgrading time.  1 Back OR
If the minimum area is not available then consult your local service representative. Every site is different and you may still  2 Left hand side
be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always  2310 mm
leave as much space as possible around the ATM to facilitate safe operation and servicing. (90.94 in.)
450 mm 480 mm 450 mm 480 mm 450 mm 300 mm
(17.72 in.) (18.90 in.) (17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.)
Single ATM 300 mm
Width of
(11.81 in.)
1 Security
Enclosure
Common Minimum Service Area
Additional areas, at least 1 required:
1 Back OR
Left hand side 1018 mm
2 2 (40.08 in.)

Width of Rear of
Security Security Enclosure
Enclosure (With Door Open)
450 mm 480 mm 450 mm 300 mm
(17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.) 2098 mm
(82.60 in.)
300 mm
(11.81 in.)
1
1080 mm
(42.52 in.)

1018 mm
2 (40.08 in.)
Maximum
100 mm
Rear of (3.94 in.)
Security Enclosure 750 mm
(With Door Open) (29.53 in.)
2098 mm
(82.60 in.)

1080 mm
(42.52 in.)

Maximum
100 mm
(3.94 in.) 750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Slim Sleeve 9 ‐ 8
CLEARANCES ‐ TOP BOX OPENING CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL
The dimensions shown assume the ATM is being moved using equipment that 
does not extend beyond the ATM or packaging. Standard Collar
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
10 mm
(0.39 in.)

A B

1730 mm
(68.11 in.)

C
45 mm
(1.77 in.)
Packaged ATM Packaged ATM
Unpackaged
(pallet, carton (pallet and
ATM
and lid) carton)
30 mm 30 mm
813 mm 812 mm 668 mm (1.18 in.) (1.18 in.)
A Doorway or straight corridor
(32.01 in.) (31.97 in.) (26.30 in.)
1120 mm 1118 mm 892 mm
B Corridor with corner
(44.09 in.) (44.02 in.) (35.12 in.) Advert Collar
1742 mm 1736 mm 1356 mm
C Rotation about centre
(68.58 in.) (68.35 in.) (53.39 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 1
PACKAGE DIMENSIONS ATM DIMENSIONS COLLAR DIMENSIONS

Standard
531 mm 656 mm
(20.91 in.) (25.83 in.)

1858 mm 1306 mm 642 mm


(73.15 in.) (51.42 in.) (25.28 in.)

775 mm
(30.51 in.) 1101 mm
(43.35 in.)

1652 mm
(65.04 in.)
610 mm
(24.02 in.)

120 mm 551 mm 24 mm
(4.72 in.) (21.69 in.) (0.94 in.)
399 mm 77 mm
1527 mm (15.71 in.) (3.03 in.)
560 mm
(60.12 in.)
(22.05 in.)
800 mm 86 mm 480 mm 86 mm
(31.50 in.) (3.39 in.) (18.90 in.) (3.39 in.)
120 mm 1031 mm 415 mm 285 mm
(4.72 in.) (40.59 in.) (16.34 in.) (11.22 in.)

1612 mm
(63.46 in.) 246 mm
(9.69 in.)
Advert

1533 mm 508 mm 581 mm 630 mm


(24.80 in.) 267 mm 656 mm 30 mm
(60.35 in.) (20.00 in.) (22.87 in.) (10.51 in.) (25.83 in.) (1.18 in.)

28 mm 480 mm 288 mm 955 mm 63 mm


(1.10 in.) (18.90 in.) (11.34 in.) (37.60 in.) (2.48 in.)
with optional 530 mm
extended (20.87 in.)
cable cover with optional UPS
1971 mm
(77.60 in.) 1101 mm
801 mm (43.35 in.)
(31.54 in.) 1919 mm
(75.55 in.)

551 mm 24 mm
(21.69 in.) (0.94 in.)
120 mm
(4.72 in.)
1527 mm 86 mm 480 mm 86 mm
560 mm
(60.12 in.) (3.39 in.) (18.90 in.) (3.39 in.)
(22.05 in.) 285 mm
800 mm
(31.50 in.) (11.22 in.)
120 mm
(4.72 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 2
WEIGHT AND FLOOR LOADING

Standard Security Enclosures

CEN I CEN III


635 kg 670 kg
Maximum weight
(1399.94 lb.) (1477.10 lb.)
1385 kg/m2 1462 kg/m2
Floor loading
(283.70 lb./ft2) (299.34 lb./ft2)

Gas and Solid Explosion Resistant (EX GAS) Security Enclosures

CEN III CEN IV


725 kg 775 kg
Maximum weight
(1598.35 lb.) (1708.58 lb.)
1582 kg/m2 1691 kg/m2
Floor loading
(323.91 lb./ft2) (346.25 lb./ft2)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 3
SECURITY BOLTS BOLT HOLES CABLE ENTRY
Bolts and anchors must be supplied by the owning organisation. The ATM must be bolted to the floor or plinth, through all the holes marked ‘A’,  480 mm
using four bolts with anchor washers. (18.9 in.)
To meet security standards the ATM must be bolted to the floor, through all of 
the bolt holes, using bolts with anchor washers as specified below. Bolts and  480 mm 265 mm 108 mm
anchor washers are to be supplied by the owning organisation. (18.9 in.) (10.43 in.) (4.25 in.)

Make sure that the floor or plinth is capable of withstanding the loading  265 mm 108 mm


imposed by the anchor points for these bolts. (10.43 in.) (4.25 in.)
149 mm
If an adjustable plinth is used, it must be bolted to the floor to the same  (5.87 in.)
specification as the ATM. 149 mm 149 mm
(5.87 in.) (5.87 in.)
The minimum specification for bolts and washers to secure the ATM to a 
A B A
concrete floor is:
 Bolts
 Type ‐ either resin anchor or shield anchor bolts 108 mm 410 mm
(4.25 in.)
 Size ‐ M16 (5/8 in.) (16.14 in.)
 Minimum Length ‐ 150 mm (5.9 in.)  410 mm
(16.14 in.) 955 mm
 Strength ‐ high tensile (minimum ISO property class 8,8).
(37.6 in.)
 Washers 955 mm
 Type ‐ flat, steel (as per DIN7349 or equivalent) (37.6 in.)

 Size ‐ M16 (5/8 in.) 

 Outer diameter ‐ no greater than 40 mm (1.58 in.)
A A 296 mm
 Minimum thickness ‐ 6 mm (0.2 in.).
(11.65 in.)

65 mm 65 mm
(2.56 in.) (2.56 in.)
55 mm 55 mm
(2.17 in.) (2.17 in.)

681 mm
(26.81 in.)

260 mm
Hole in the wall
(10.24 in.)

Centre-line
security enclosure

Hole A Bolt Holes Hole B (Alarm Hole)


21.5 mm 32.5 mm
(0.85 in.) (1.28 in.)

21 mm 25 mm
(0.83 in.) 40 mm (0.98 in.) 40 mm
(1.57 in.) (1.57 in.)

13 mm 14 mm
(0.51 in.) (0.55 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 4
HOLE IN THE WALL

Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from 
the sidewalk level to the facia items comply with any local regulations. Where 
no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height 
between the sidewalk and the interior floor. If there is no difference then the 
plinth must have the height specified in the illustrations below.
620 mm
(24.41 in.)

1069 mm
Hole in Wall
(42.09 in.)

750 mm 184 mm
(29.53 in.) (7.24 in.)
Security Enclosure

Sidewalk Plinth

260 mm (10.24 in.) View from Inside Building


Maximum

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 5
FACIA ITEMS Heights and Depths Distance for Voice Guidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
JKL
Touchscreen 1216 mm 527 mm 9 3 No. 5 Key
5 Top
381 mm (15.0 in.) (47.87 in.) (20.75 in.) 8
7 6 5
4

Display with FDKs 1140 mm 470 mm


Top FDK
381 mm (15 in.) (44.88 in.) (18.50 in.)
168 mm
Card Reader 2
963 mm 406 mm (6.61 in.)
Card Reader
(37.91 in.) (15.98 in.)
156 mm
Contactless Card Reader (behind Facia) 3
963 mm 406 mm (6.14 in.)
Receipt
S
(37.91 in.) (15.98 in.)
183 mm
Private Audio 4
913 mm 366 mm (7.20 in.)
5
JKL
PIN Pad Number 5 key
(35.94 in.) (14.41 in.)
125 mm
S Cash Exit/Entry 6
909 mm 357 mm (4.92 in.)
Contactless Card Reader (behind Facia)
(35.79 in.) (14.06 in.)
265 mm
Barcode Reader 7
909 mm 357 mm (10.43 in.)
Biometric Reader
(35.79 in.) (14.06 in.)
111 mm
Biometric Reader 9
Topmost Viewable Facia Item 882 mm 299 mm (4.37 in.)
Private Audio
(34.72 in.) (11.77 in.)
The topmost viewable facia item is the 15 in. touchscreen. 125 mm
Receipt 10
838 mm 265 mm (4.92 in.)
S Cash Exit/Entry
(32.99 in.) (10.43 in.)
Display with FDKs Top Left 291 mm
11
616 mm 76 mm 381 mm (15 in.) FDK (11.46 in.)
Barcode Reader Activation Point
(24.25 in) (2.99 in.)
239 mm
Touchscreen Middle 12
(9.41 in.)

19°

381 mm (15 in.) Touchscreen

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 6
SERVICING AREAS ‐ OPTIMUM Side By Side
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks. Optimum Service Area

Wherever possible the ATM should be installed within the optimum servicing area.
2460 mm
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the  (96.85 in.)
minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area. 500 mm 480 mm 500 mm 480 mm 500 mm
(19.69 in.) (18.90 in.) (19.69 in.) (18.90 in.) (19.69 in.)
If you install in the minimum area then note that doors may open, and devices rack out, beyond the area shown. Always 
Width of
leave as much space as possible around the ATM to facilitate safe operation and servicing. Security
Enclosure 500 mm
(19.69 in.)
Single ATM

Optimum Service Area

500 mm 480 mm 500 mm


(19.69 in.) (18.90 in.) (19.69 in.) 1018 mm
(40.08 in.)
Width of
Security
Enclosure Rear of
2758 mm
(108.58 in.) Security Enclosure
(With Door Open)
500 mm
(19.69 in.)

1240 mm
(48.82 in.)

1018 mm
(40.08 in.)

Rear of
2758 mm
Security Enclosure
(108.58 in.)
(With Door Open)
Maximum
260 mm
(10.24 in.)
750 mm
(29.53 in.)

1240 mm
(48.82 in.)

Maximum
260 mm
(10.24 in.)
750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 7
SERVICING AREAS ‐ MINIMUM Side By Side
This is the minimum area required for operating and servicing the ATM. Common Minimum Service Area
Additional areas, at least 1 required:
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum 
1 Back OR
servicing area may increase the servicing and/or upgrading time. 
2 Left hand side
If the minimum area is not available then consult your local service representative. Every site is different and you may still 
be able to install the ATM but with further increases to servicing and/or upgrading time.
2310 mm
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always  (90.94 in.)
leave as much space as possible around the ATM to facilitate safe operation and servicing. 450 mm 480 mm 450 mm 480 mm 450 mm 300 mm
(17.72 in.) (18.90 in.) (17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.)
300 mm
Single ATM (11.81 in.) Width of
1 Security
Enclosure
Common Minimum Service Area
Additional areas, at least 1 required:
1 Back OR

2 Left hand side 1018 mm


2 (40.08 in.)

Width of Rear of
Security Security Enclosure
Enclosure (With Door Open)
450 mm 480 mm 450 mm 300 mm
(17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.) 2258 mm
300 mm (88.90 in.)
(11.81 in.)
1
1240 mm
(48.82 in.)

1018 mm
2 (40.08 in.)

Rear of Maximum
Security Enclosure 260 mm
(With Door Open) (10.24 in.)
750 mm
2258 mm
(29.53 in.)
(88.90 in.)

1240 mm
(48.82 in.)

Maximum
260 mm
(10.24 in.)
750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Short Sleeve 10 ‐ 8
CLEARANCES ‐ TOP BOX OPENING CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL
The dimensions shown assume the ATM is being moved using equipment that 
does not extend beyond the ATM or packaging. Standard Collar
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
10 mm
(0.39 in.)

A B

1730 mm
(68.11 in.)

C
45 mm
(1.77 in.)
Packaged ATM Packaged ATM
Unpackaged
(pallet, carton (pallet and
ATM
and lid) carton)
30 mm 30 mm
813 mm 812 mm 668 mm (1.18 in.) (1.18 in.)
A Doorway or straight corridor
(32.01 in.) (31.97 in.) (26.30 in.)
1120 mm 1118 mm 948 mm
B Corridor with corner
(44.09 in.) (44.02 in.) (37.32 in.) Advert Collar
1742 mm 1736 mm 1499 mm
C Rotation about centre
(68.58 in.) (68.35 in.) (59.02 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 1
PACKAGE DIMENSIONS ATM DIMENSIONS COLLAR DIMENSIONS

Standard
601 mm
(23.66 in.)
656 mm
(25.83 in.)

1376 mm 642 mm
(54.17 in.) (25.28 in.)
1858 mm
(73.15 in.)
775 mm
(30.51 in.) 1101 mm
(43.35 in.)

1652 mm
(65.04 in.)
610 mm
(24.02 in.)

120 mm 469 mm 77 mm
(18.46 in.) (3.03 in.) 551 mm 24 mm
(4.72 in.)
(21.69 in.) (0.94 in.)
1527 mm
560 mm
(60.12 in.)
(22.05 in.)
800 mm 86 mm 480 mm 86 mm 355 mm
(31.50 in.) 1029 mm 415 mm
(40.51 in.) (3.39 in.) (18.90 in.) (3.39 in.) (13.98 in.)
120 mm (16.34 in.)
(4.72 in.)
1612 mm
(63.46 in.) 246 mm
(9.69 in.)
Advert

508 mm 583 mm 630 mm 267 mm 656 mm 30 mm


1533 mm (20.00 in.) (22.95 in.) (24.80 in.) (10.51 in.) (25.83 in.) (1.18 in.)
(60.35 in.)

28 mm 480 mm 358 mm 955 mm 63 mm


(1.10 in.) (18.90 in.) (14.09 in.) (37.60 in.) (2.48 in.)
with optional 530 mm
extended (20.87 in.)
cable cover with UPS 1101 mm
(43.35 in.)
1971 mm
(77.60 in.) 1919 mm
801 mm (75.55 in.)
(31.54 in.)

551 mm 24 mm
(21.69 in.) (0.94 in.)

120 mm
(4.72 in.) 86 mm 480 mm 86 mm 355 mm
1527 mm (3.39 in.) (19.90 in.) (3.39 in.) (13.98 in.)
560 mm
(60.12 in.)
(22.05 in.)
800 mm
(31.50 in.)
120 mm
(4.72 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 2
WEIGHT AND FLOOR LOADING

Standard Security Enclosures

CEN I CEN III


635 kg 670 kg
Maximum weight
(1399.94 lb.) (1477.10 lb.)
1385 kg/m2 1462 kg/m2
Floor loading
(283.70 lb./ft2) (299.34 lb./ft2)

Gas and Solid Explosion Resistant (EX GAS) Security Enclosures

CEN III CEN IV


725 kg 775 kg
Maximum weight
(1598.35 lb.) (1708.58 lb.)
1582 kg/m2 1691 kg/m2
Floor loading
(323.91 lb./ft2) (346.25 lb./ft2)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 3
SECURITY BOLTS BOLT HOLES CABLE ENTRY
Bolts and anchors must be supplied by the owning organisation. The ATM must be bolted to the floor or plinth, through all the holes marked ‘A’, 
using four bolts with anchor washers. 480 mm
To meet security standards the ATM must be bolted to the floor, through all of 
(18.9 in.)
the bolt holes, using bolts with anchor washers as specified below. Bolts and  480 mm
anchor washers are to be supplied by the owning organisation. (18.9 in.)
265 mm 108 mm
Make sure that the floor or plinth is capable of withstanding the loading  (10.43 in.) (4.25 in.)
265 mm 108 mm
imposed by the anchor points for these bolts. (10.43 in.) (4.25 in.)

If an adjustable plinth is used, it must be bolted to the floor to the same  149 mm
specification as the ATM. 149 mm 149 mm (5.87 in.)
(5.87 in.) (5.87 in.)
The minimum specification for bolts and washers to secure the ATM to a  A B A
concrete floor is:
 Bolts
 Type ‐ either resin anchor or shield anchor bolts 108 mm
(4.25 in.)
 Size ‐ M16 (5/8 in.)
410 mm
 Minimum Length ‐ 150 mm (5.9 in.)  410 mm (16.14 in.)
(16.14 in.)
 Strength ‐ high tensile (minimum ISO property class 8,8).

 Washers 955 mm 955 mm


(37.6 in.) (37.6 in.)
 Type ‐ flat, steel (as per DIN7349 or equivalent)

 Size ‐ M16 (5/8 in.) 

 Outer diameter ‐ no greater than 40 mm (1.58 in.)
A A
 Minimum thickness ‐ 6 mm (0.2 in.).
296 mm
(11.65 in.)

65 mm 65 mm
(2.56 in.) (2.56 in.)
55 mm 55 mm
(2.17 in.) (2.17 in.)

751 mm
(29.57 in.)

330 mm
Hole in the wall
(12.99 in.)

Centre-line
security enclosure

Hole A Bolt Holes Hole B (Alarm Hole)


21.5 mm 32.5 mm
(0.85 in.) (1.28 in.)

21 mm 25 mm
(0.83 in.) 40 mm (0.98 in.) 40 mm
(1.57 in.) (1.57 in.)

13 mm 14 mm
(0.51 in.) (0.55 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 4
HOLE IN THE WALL

Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from 
the sidewalk level to the facia items comply with any local regulations. Where 
no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height 
between the sidewalk and the interior floor. If there is no difference then the 
plinth must have the height specified in the illustrations below.
620 mm
(24.41 in.)

1069 mm
Hole in Wall
(42.09 in.)

750 mm 184 mm
(29.53 in.) (7.24 in.)
Security Enclosure

Sidewalk Plinth

330 mm (12.99 in.) View from Inside Building


Maximum

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 5
FACIA ITEMS Heights and Depths Distance for Voice Guidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
JKL Touchscreen 1216 mm 597 mm 9 3 No. 5 Key
5 Top
381 mm (15.0 in.) (47.87 in.) (23.50 in.) 8
7 6 5
4

Display with FDKs 1140 mm 540 mm


Top FDK
381 mm (15 in.) (44.88 in.) (21.26 in.)
168 mm
Card Reader 2
963 mm 476 mm (6.61 in.)
Card Reader
(37.91 in.) (18.74 in.)
156 mm
Contactless Card Reader (behind Facia) 3
963 mm 476 mm (6.14 in.)
Receipt
S
(37.91 in.) (18.74 in.)
183 mm
Private Audio 4
913 mm 436 mm (7.20 in.)
5
JKL
PIN Pad Number 5 key
(35.94 in.) (17.17 in.)
125 mm
S Cash Exit/Entry 6
909 mm 427 mm (4.92 in.)
Contactless Card Reader (behind Facia)
(35.79 in.) (16.81 in.)
265 mm
Barcode Reader 7
909mm 427 mm (10.43 in.)
Biometric Reader
(35.79 in.) (16.81 in.)
111 mm
Biometric Reader 9
Topmost Viewable Facia Item 882 mm 369 mm (4.37 in.)
Private Audio
(34.72 in.) (14.53 in.)
The topmost viewable facia item is the 15 in. touchscreen. 125 mm
Receipt 10
838 mm 335 mm (4.92 in.)
S Cash Exit/Entry
(32.99 in.) (13.19 in.)
Display with FDKs Top Left 291 mm
11
616 mm 146 mm 381 mm (15 in.) FDK (11.46 in.)
Barcode Reader Activation Point
(24.25 in) (5.75 in.)
239 mm
Touchscreen Middle 12
(9.41 in.)

19°

381 mm (15 in.) Touchscreen

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 6
SERVICING AREAS ‐ OPTIMUM Side By Side
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks. Optimum Service Area
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the  2460 mm
(96.85 in.)
minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
500 mm 480 mm 500 mm 480 mm 500 mm
If you install in the minimum area then note that doors may open, and devices rack out, beyond the area shown. Always  (19.69 in.) (18.90 in.) (19.69 in.) (18.90 in.) (19.69 in.)
leave as much space as possible around the ATM to facilitate safe operation and servicing.
Width of
Security
500 mm
Enclosure
(19.69 in.)
Single ATM

Optimum Service Area

500 mm 480 mm 500 mm


(19.69 in.) (18.90 in.) (19.69 in.) 1018 mm
Width of (40.08 in.)
Security
Enclosure
Rear of
2828 mm Security Enclosure
(111.34 in.) (With Door Open)
500 mm
(19.69 in.)

1310 mm
(51.57 in.)
1018 mm
(40.08 in.)

Rear of
2828 mm Security Enclosure
(111.34 in.) (With Door Open)

Maximum
330 mm
(12.99 in.) 750 mm
(29.53 in.)

1310 mm
(51.57 in.)

Maximum
330 mm
(12.99 in.)
750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 7
SERVICING AREAS ‐ MINIMUM Side By Side
This is the minimum area required for operating and servicing the ATM. Common Minimum Service Area
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum  Additional areas, at least 1 required:
servicing area may increase the servicing and/or upgrading time.  1 Back OR
2 Left hand side
If the minimum area is not available then consult your local service representative. Every site is different and you may still 
be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always  2310 mm
leave as much space as possible around the ATM to facilitate safe operation and servicing. (90.94 in.)
450 mm 480 mm 450 mm 480 mm 450 mm 300 mm
(17.72 in.) (18.90 in.) (17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.)
Single ATM 300 mm
Width of
(11.81 in.)
1 Security
Common Minimum Service Area Enclosure

Additional areas, at least 1 required:


1 Back OR

2 Left hand side


1018 mm
2 (40.08 in.)
Width of
Security Rear of
Enclosure Security Enclosure
450 mm 480 mm 450 mm 300 mm (With Door Open)
(17.72 in.) (18.90 in.) (17.72 in.) (11.81 in.)
2328 mm
300 mm
(91.65 in.)
(11.81 in.)
1

1310 mm
(51.57 in.)

1018 mm
2 (40.08 in.)

Rear of
Security Enclosure
(With Door Open) Maximum
2328 mm
(91.65 in.) 330 mm
(12.99 in.)
750 mm
(29.53 in.)

1310 mm
(51.57 in.)

Maximum
330 mm
(12.99 in.)
750 mm
(29.53 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000
 NCR SelfServ™ 87 ATM Site Preparation Guide
Variant Details ‐ Standard Sleeve 11 ‐ 8
CLEARANCES ‐ TOP BOX OPENING CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL
The dimensions shown assume the ATM is being moved using equipment that 
does not extend beyond the ATM or packaging. Standard Collar
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
10 mm
(0.39 in.)

A B

1730 mm
(68.11 in.)

C
45 mm
(1.77 in.)
Packaged ATM Packaged ATM
Unpackaged
(pallet, carton (pallet and
ATM
and lid) carton)
30 mm 30 mm
813 mm 812 mm 668 mm (1.18 in.) (1.18 in.)
A Doorway or straight corridor
(32.01 in.) (31.97 in.) (26.30 in.)
1120 mm 1118 mm 973 mm
B Corridor with corner
(44.09 in.) (44.02 in.) (38.31 in.) Advert Collar
1742 mm 1736 mm 1562 mm
C Rotation about centre
(68.58 in.) (68.35 in.) (61.50 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2015–2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7345‐E000