You are on page 1of 1

A1 A B C D E F G H I J K L M N

Notes

10/12/2014 17:14:30
1.This drawing is to be read in conjunction with the
relevant Architectural drawings and specifications,
and relevant documents by others.
1
2.For building setting out refer to Architects
drawings.

3.All levels are in metres above ordnance datum


Column above shown (AOD), unless noted otherwise.
indicatively Column above shown
indicatively
4.All dimensions are in millimetres unless noted
otherwise.

5. Confirmed dimensions are noted. Do not scale


from drawing
SSL +15.000 m SSL +15.000 m
Level 0 Level 0
2

Pile cap Thickness


Pile cap thickness
Top of pile 75mm Top of pile (TBC 150 150
into pile cap
+12.575 m by conctractor)
+12.500 m
75

3
150 150 Concrete 'plinth' required where top of pile
level is less than underside of pilecap
50mm Blinding

Piles shown as 900dia CFA, pile 50mm Blinding


reinforcement shown indicatively,
design by Contractor
Piles shown as 900dia CFA, pile
reinforcement shown indicatively,
design by Contractor

CFA pile limited to 29m CFA pile limited to 29m


4
maximum length. I.e maximum length. I.e Toe
Toe depth: -16moD. depth: -16moD. (Actual
(Actual toe level TBC toe level TBC by
-5.575 m Design)
by Contractor -4.875
Contractor m
Design)

3 x pile dia typically spacing. UNO 3 x pile dia typically spacing. UNO 3 x pile dia typically spacing. UNO
TBC by contractor design TBC by contractor design TBC by contractor design

5
1 Typical Pile - Pile Cap Detail: Pile cut off within pile cap 2 Typical Pile - Pile Cap Detail: Pile cut-off below pile cap
1 : 50 1 : 50

P2 10/12/14 JS SC DE
Issued for inclusion in planning submission
P1 09/12/14 JS SC DE
Issued for information in pile tender package
Rev Date By Chkd Appd

8 Fitzroy Street
London W1T 4BQ
Tel +44(0)20 7636 1531 Fax +44(0)20 7580 3924
www.arup.com

Client

STRATFORD CITY BUSINESS


9
DISTRICT LTD

Project Title

THE INTERNATIONAL QUARTER


PLOT S5

Drawing Title
10 PILE CAP DETAILS

Scale at A1
1 : 50
Role
STRUCTURAL
Suitability
PLANNING
Arup Job No Rev
11
237038 P2
Name

S-160-DE-PF-001

Do not scale © Arup

You might also like