SECTION 4 − INSTALLATION

4-1. Serial Number and Rating Label Location


The serial number and rating information for the power source is located on the front of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Specifications

Amperes Input at
Rated Load Output
Output Rated Output Required 50 or 60 Hz, Overall IP
Frequen Reflective Three-Phase Weight
Dimensions Rating
cy Inductance
Single Dual
400 V 460 V 575 V kVA kW
Output Output
35 kW At 35 kW At
100% 100% Length: 36-3/4 in
Duty Duty (993 mm)
5 To 30 Cycle Cycle 2.5 To 50 Width: 21-1/2 in 227 lb
60 A 50 A 40 A 39 37 23CM
kHz 350 A 700 A μh (546 mm) (103 kg)
(RMS), (RMS), Height: 29 in
700 V 700 V (737 mm)
(RMS) (RMS)
Storage Temperature Range −40_ F (−40_ C) to 122_ F (50_ C)
*While idling

4-3. Selecting A Location


1 Lifting Eye
2 Lifting Forks
Use lifting eye or lifting forks to
Movement move unit.
If using lifting forks, extend forks
1 beyond opposite side of unit.
3 Line Disconnect Device
Locate unit near correct input
power supply.
OR ! Special installation may be
2 required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Location And Airflow
3

12 in
(305 mm)

18 in
(460 mm)

12 in
(305 mm)

18 in
(460 mm)
803 992-B

OM-222 166 Page 10