You are on page 1of 3

QT Systems

PO Box 6249 Acacia Ridge DC Q 4110 Australia


Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Rebated Slab
30 Wall
(AS4.1.C) Nom. Panel

Render

Panel Fixing
Vapour Permeable Sarking
Panel

Steel or Timber
Batten
Steel or Timber Stud
Damp Proof Membrane
below bottom plate and
fixed to studs with class
3 fixings.

Weepholes
Slab-on-ground

Sealant
50

Ground Level
150 Min. To
Paved Level

175 Min. To
15

Visual Termite
75 Min.

Barrier

Min 1:20 Fall away


from building
15 Nom.
Min.
50

Exterior Grade Weatherproof Sealant

Backing Rod

Damp Proof Membrane

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT®Buttons at 225mm centres
as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.
QT Systems
PO Box 6249 Acacia Ridge DC Q 4110 Australia
Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Suspended Floor
(AS-4.3.B) 30 Wall
Nom. Panel

Vapour Permeable Sarking

Render
Steel or Timber Stud

Panel Fixing
Floor Framing

Flooring

Panel

Steel or Timber
Batten

Provide blocking member


between joists to maintain a
continuous sealed cavity

Weepholes (Optional)
50

Steel or Timber Bearer 2 Part Panel Boot to


finish off base of Panel

Under Batten

Termite Barrier

Support Post

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT®Buttons at 225mm centres
as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.
QT Systems
PO Box 6249 Acacia Ridge DC Q 4110 Australia
Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Flush Slab
(AS-4.2.B) 30 Wall
Nom. Panel

Render

Vapour Permeable Sarking Panel

Panel Fixing

Steel or Timber Stud


Steel or Timber
Batten

Slab-on-ground Damp Proof Membrane


below bottom plate and
fixed to studs with class
3 fixings.

Weepholes (Optional)

FINISHED FLOOR LEVEL


Min.
50

Ground Level
125 Min. To
Paved Level

150 Min. To
Visual Termite
75 Min.

Barrier

Min 1:20 Fall away


from building

2 Part Panel Boot to


finish base of Panel.

Note
All panel fixings to be 10g x 75mm class 3 screws or 75 x 3.15 ø or 3.75 ø class 3 ring shank nails with QT®Buttons at 225mm centres
as per technical manual section 2. Batten fixings should be class 3 and as section 2 of the technical manual.