GD-200 SERIES PRESSURE REDUCING VALVES ARE WIDELY USED FOR

CONSTRUCTION EQUIPMENT, AIR CONDITIONING EQUIPMENT, FACTORY


EQUIPMENT, INDUSTRIAL EQUIPMENT, ETC. THEY GUARANTEE BOTH
STABLE REDUCED PRESSURE AND A LARGE FLOW RATE.

• Features
1. Pressure balancing mechanism enables stable reduced pressure
without affecting the inlet pressure.
2. The stainless steel made valve seat enables high resistant to
corrosion.
3. Easy maintenance and inspection. Internal inspection can be easily
done because disassembly is done from the top in only one direction.
4. The main valve features a single seat and disc, thereby eliminating
leakage.
5. Maximum inlet pressure is up to 2.0MPa because of ductile cast iron
body for model GD-200H.

• Specification
Model GD-200 I GD-200H
Application Water,_Oil , Air, Non-corrosive fluids
Connection JIS 10K FF Flanged I JIS 20K RF Flanged
Inlet pressure 1.0MPa {10kgf/cm2G} or less I 2.0MPa {20kgf/cm2G} or less
Reduced I 15A-8OA 0.05-0.25MPa {0.5-2.5kgf/cm2G} 0.26-0.7MPa {2.6-7kgf/cm2G}
pressure I 100A-15OA 0.05-0.25MPa {0.5-2.5kgf/cm2G} 0.26-0.5MPa {2.6-5kgf/cm2G}
M in. differential pressure 0.05MPa {0.5kgf/cm2}
Max. pressure reduction ratio 10: 1
Temperature 5-80'C*
Valve seat leakage None
Body Ductile Cast Iron
Iii
.~ Valve I Diaphragm NBR*
Iii Valve Seat Stainless Steel (SUS304)**
::2: Spindle Stainless Steel (SUS303 or 304)**
e Viscosity: 600 cSt or less
• Rubber parts: FKM is also available (Max. temperature 90°C)
•• Trim (Valve seat, Spindle) material (SUS316) is also available (GD-200HS).

)
• Dimensions and Weights
NominalSize L H H1
(mm)

Weight(kg)
\CJ ::c
15A 145 297 57 8.2
20A 150 297 57 8.2
25A 150 320 67 10.0
32A 195 397 76 17.3 I,
40A 195 397 76 17.3
I
50A 195 415 81 19.2
_, ill ,_
65A 270 555 110 40.0 &-
80A 270 582 125 43.7 I /'l II:f
100A 308 645 143 70.7
125A 380(384) 849 179 144(145)
150A 400(404) 918 204 173(175) L
eL and Weight shown in parenthesis are for GD-200H.

osbitake
• Nominal Size Selection Chart
.For Water .For Air
d.. I II
IJominJr Sir
lS0A-'- 0.7
,0' f- 0.8 0.9
1.o_1.2
10} 12 MH~'~}Ah(~g} 7 8
200I
V II ••~
n, I~
lfU {8} 9}" \ \
E
lS0 I
yv -WA
0.6
l'_o.s
(7) i"-

I"
s 0
:;:,
C>
I '---
V ~ I- ~., {S}
Co

1= <l.i'r+05 "
./ /' 0.5 5
100I
100A
:0
II)
II)
~
:0
80I ~ 0.4
a,
{S}
,... \. 4
II)
II)

1/"/ 1--0.4 ~
c,
60I .~- {4}
80A- '- Qi
0.3 3
II
'S
0
..
<I."R=
0.3
{3}
Qi
'S
40
Lv" .....•
V' 1
6 A
r d::
0.2
0.2
2 0
_
f.
.s 20
30
I.--
t.-
v .......- IsbA_ l-
0.1
0.1 {I}
{2} <,
I'..

r.e0
d::

I.-- V
J!!
e ./ 1 ,,0 I.--M I.-l.--- j::: Vv ~ i--" I---"
I--- V ~
lS 46A f:,00 c-
~ t.-t.- V II32A- § r.e I--NominalSB~ ~ [..... ~ L.--~ o
u; 10
/'" L..- :g
5
v§.)
'00
:-? ~ l..- V [..... ,.;' ....- I---" ~
'000
\000 ~<:
> 20A 0
8I •....
'::-
0

6i 12~A-
l-
~ \00
I-<
~5A
I---" I.; V E:i- ~ ,/-000 n;
V' E 32A
.s= :.,...1--"" ~ J...... :.,... ,,000 E0
g
4
v iJ A s:
,/-00
~
pj...<
~40A
t::j..-~
L.-- v ~000 c
s:
;;;-
V ?P ~ ,,00 SoA
J.....- I,;;;;
J...... •..... '0000 .s
V ~ J......
V
3I

,
1.--]....
-ll A
_
I-
-;;

1§ '000
~OO
~j;~I:::I---"
j;;;. BOA
--- v
[..... I---"l--' '0
000
\0000 ~
s0
2
]....
;:'000 I_,..J......I---"j..-~ L..- V '-"" t::: t::: j..-V
l,....- 00
~ \000 l--- '/-00 u:
1.S;

rr:
~ looA \......
a ~5AJ.,...""" V [..... •..... ,,0000 a I
,/-000 •.... i.--- I,....- j..-•.... ~0000
l::l.---l.---~ •.....
i--"
,,000
p.
L.--
I.;~ V l.---VJ.,...j..-V I---" '-""
O.OS 0.1 0.2 0.4 0.6 0.8 1.0 2.0 ~00°
{O.S} {1} {2} {4} {6} {8}{10} {20} '0000 '000\0000 '2.0000 ,,0000 40000
.6.P : Differential pressure MPa {kgf/cm2}

• Nominal Size Selection Formula


.Calculation formula for Cv value .Viscosity compensation curve
(For gas) First, find viscosity index Iv. ,--,'
In case of P2> i 1
Cv= 2~0
(273+t) G
.6P(Pl+P2) Iv= 72780 (.6PitGt
Mcst G:J
O/(273+t)G Find K from calculated Iv on the viscosity compensation curve.
In case of P2~
- 2
E.L Cv
2550Pl The calculated maximum flow rate (V) devided by K is the value
of the compensatedflow rate.
0.365V/G
(For liquid) Cv
~
2.4 \
p,: Inletpressure(MPa'A) t: Fluidtemperature(C) 2.3
P2:Reducedpressure(MPa'A) V: Maximumflowrateof liquid
Ll.P:P,-P2 (MPa) (m3th) _ 2.2
Compensated ;\
Q: Maximumflow rateof Gas Cv:Cvvalueof specified -§ 2.1
maximumflow rate: .£!! 2.0 \
(m3th,normalcondition) nominalsize
G: Specificgravity(Gas:specific Iv:Viscosityindex V'=V/K (m3/h) c
~ 1.9
gravityto air, Liquid:specific Mcst:Viscosity(cSt) II) 1.8
gravityto water) [ 1.7
g 1.6
o 1.S
~ 1.4 \
\.
1.3
1.2
1.1
"-
1.0
20 3040 6080100 --
200 300 5007001000 2000 3000
Iv: Viscosityindex

• Product lineup for GD·200 series


GD-200C Nylon coated pressure reducing valve (Coated with Nylon both inside and outside of body for superior anti-corrosion)
GD-20R Primary pressure regulating valve (Used in by-pass systems to prevent pump shut-off and to maintain a constant
pressure in the line)
GD-20R Pressure sustaining valve (Used as a pressure sustaining valve to prevent dripping induced by gravitational force when
the pump is turned off)
GD-21 Differential pressure regulating valve (Used as the pump relief valve in closed circuit of air conditioning equipment in
high-rise building) \...,....-

Y/osbltake
~~~~INC.
INTERNATIONAL DEPT.
7-3, Futano-cho, Mizuho-ku, Nagoya, 467-0861, Jap~~ . .
http://www.yoshitake.jp Phone: 81-52-881-7199 Fax: 81-52-881-7201 E-mall:lntntl@yoshitake.co.]p
Yoshitake reserves the right to Change the materials or design of the products shown in this catalogue without prior notice.
PrintedinJapan.34-2-17-08

You might also like