Ekinops PM C1001HC(-ETR) documentation


1 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Product Features

Introduction
Product Features

 One 10GbELAN or SMT64/OC192 client port interface

 Proprietary line format, 11.09 Gb/s bite rate

 SFP+ module for client port physical interface

 OTX module 40, 60 and 80 kms B&W or DWDM for line interface

 DDM from SFP+ and OTX

Ekinops PM C1001HC(-ETR) documentation


2 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Product Features

___________________________________________________________________________
! Warning. PM-C1001HC(-ETR) can be plugged and installed into a C600 chassis with
the following restriction: a PM-FILLER8 must be placed in the slot right after the PM-
C1001HC(-ETR).
PM-C1001HC(-ETR) will be irretrievably damaged if the above condition of use is not
applied
___________________________________________________________________________

___________________________________________________________________________
! Avertissement. Le module PM-C1001HC(-ETR) peut être inséré et installé dans un
châssis C600 sous la condition suivante : un PM-FILLER8 doit être installé dans le slot
suivant immédiatement le PM-C1001HC(-ETR).
Le PM-C1001HC(-ETR) sera endommagé de manière irreversible si la condition
d’utilisation ci-dessus n’est pas respectée.
___________________________________________________________________________

Ekinops PM C1001HC(-ETR) documentation


3 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Contents

Contents
Introduction ......................................................................................................................................... 2
Product Features ......................................................................................................................................... 2
Contents ....................................................................................................................................................... 4
Figures .......................................................................................................................................................... 6
Tables ........................................................................................................................................................... 6
History .......................................................................................................................................................... 7
References .................................................................................................................................................... 7
Document ..................................................................................................................................................... 7
Description ................................................................................................................................................... 8
Chapter A Technical Specification ............................................................................................... 9
A.1 Functional Description................................................................................................................. 10
A.1.1 General ...................................................................................................................................................... 10
A.1.2 Upstream section....................................................................................................................................... 12
A.1.2.1 Input Ports interfacing ..................................................................................................................... 12
A.1.2.2 Justification and Mapper ................................................................................................................. 13
A.1.2.3 Framer ............................................................................................................................................. 14
A.1.2.4 Line Optical Interfacing .................................................................................................................. 14
A.1.3 DownStream Section ................................................................................................................................ 16
A.1.3.1 Line Optical Interfacing .................................................................................................................. 16
A.1.3.2 De-Framer ....................................................................................................................................... 16
A.1.3.3 De-Mapper ...................................................................................................................................... 17
A.1.3.4 64B/66B encoder and output port interfacing ................................................................................. 18
A.1.4 Maintenance Loop backs .......................................................................................................................... 20
A.1.4.1 OTX XFI loop back ......................................................................................................................... 20
A.1.4.2 OTX Line loop back ........................................................................................................................ 20
A.1.5 Clock Generation Unit .............................................................................................................................. 24
A.1.5.1 UpStream Clock Generation Unit ................................................................................................... 24
A.1.5.2 DownStream Clock Generation Unit ............................................................................................... 24
A.1.6 Controller Block ....................................................................................................................................... 24
A.1.7 Out of Service and In Service states ......................................................................................................... 25
A.1.7.1 Client port........................................................................................................................................ 25
A.1.7.2 Line port .......................................................................................................................................... 25
A.1.7.3 PM C1001HC(-ETR) ...................................................................................................................... 25
A.1.8 Power Supplies ......................................................................................................................................... 26
A.2 FEC performance ......................................................................................................................... 26
A.3 Interface Specifications................................................................................................................ 27
A.3.1 Client Interfaces Optical Characteristics ................................................................................................... 27
A.3.2 PM C1001HC(-ETR)-XO Line Interface characteristics .......................................................................... 28
A.3.2.1 OTX-VLH (Tunable) Line Interface characteristics ....................................................................... 28
A.4 Electrical and Environmental conditions ................................................................................... 29
A.4.1 Power Consumption .................................................................................................................................. 29
A.4.2 Ambient operating Temperature ............................................................................................................... 29
A.4.3 Storage Temperature ................................................................................................................................. 29
A.5 PM C1001HC(-ETR) Front Panel Layout ................................................................................. 30
A.5.1 PM C1001HC ........................................................................................................................................... 30
A.5.2 PM C1001HC-ETR................................................................................................................................... 31
Chapter B SNMP User Manual.................................................................................................. 33
Ekinops PM C1001HC(-ETR) documentation
4 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Contents

B.1 General .......................................................................................................................................... 34


B.2 Configuration ............................................................................................................................... 34
B.2.1 Access Configuration ................................................................................................................................ 34
B.2.1.1 Client Port Configuration ................................................................................................................ 34
B.2.1.2 Line Configuration .......................................................................................................................... 36
B.2.1.3 Line Optical Interface Configuration .............................................................................................. 37
B.2.2 How to modify the Configuration ............................................................................................................. 39
B.3 Monitoring .................................................................................................................................... 41
B.3.1 Counters .................................................................................................................................................... 41
B.3.2 Remote Monitoring Counters.................................................................................................................... 43
B.3.3 Performance Monitoring ........................................................................................................................... 45
B.3.3.1 Performance Monitoring Synchronization ...................................................................................... 45
B.3.3.2 Performance Monitoring Time Stamp ............................................................................................. 45
B.3.3.3 Performance Monitoring Statistics .................................................................................................. 46
B.3.4 Measures ................................................................................................................................................... 47
B.3.4.1 Temperature .................................................................................................................................... 47
B.3.4.2 Bias .................................................................................................................................................. 48
B.3.4.3 Transmit Power ............................................................................................................................... 49
B.3.4.4 Receive Power ................................................................................................................................. 50
Appendixes......................................................................................................................................... 51
Appendix A: Laser Class .......................................................................................................................... 52
Appendix B: PM C1001HC(-ETR)Leds description.............................................................................. 53
Appendix C: PM C1001HC MIB description ......................................................................................... 54

Ekinops PM C1001HC(-ETR) documentation


5 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Contents

Figures
Figure 1 PM C1001HC(-ETR) Block diagram ............................................................................................................. 11
Figure 2 Upstream Client Signal Fail assertion principle ........................................................................................... 14
Figure 3 Downstream CSF detection mechanism ........................................................................................................ 18
Figure 4 Downstream CAIS mechanism ...................................................................................................................... 18
Figure 5 Signal data path in OTX XFI loop-back operation ........................................................................................ 22
Figure 6 Signal data path in OTX line loop-back operation ........................................................................................ 23
Figure 7 PM C1001HC-O front panel layout............................................................................................................... 30
Figure 8 PM C1001HC-X front panel layout ............................................................................................................... 30
Figure 9 PM C1001HC-O front panel layout (new!) ................................................................................................... 30
Figure 10 PM C1001HC-X front panel layout (new!) ............................................................................................... 30
Figure 11 PM C1001HC-ETR-O front panel layout ................................................................................................. 31

Tables
Table 1 PM C1001HC(-ETR) range description .......................................................................................................... 8
Table 2 FEC Performance .......................................................................................................................................... 26
Table 3 OTX-VLH Optical Characteristics ................................................................................................................ 28

Ekinops PM C1001HC(-ETR) documentation


6 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Document Description

History
No. Date Status
th
Rev 2.11 August 16 2016 Minor correction
th
Rev 2.10 March 26 2014 Added PM C1001HC-ETR description
th Updated ekinops Logo
Rev 2.00 July 5 2013
Updated Front panel
th
Rev 1.30 March 7 2012 Updated warning notice on page 3
th
Rev 1.22 November 15 2011 Removed client loopback function
th
Rev 1.21 October 18 2011 Minor correction
nd
Rev 1.20 Sept 2 2010 Added a Warning on PM-C1001HC use in C600HC and C200 only
Updated SNMP User Guide
th
Rev 1.10 August 11 2010 Added RMON description in Technical Description
Added RMON and Performance Monitoring description in SNMP User Guide
th
Rev 1.00 June 4 2010 Document creation

References
[1] GR-253, issue 3, September 2000
[2] ITU-T G.707/Y.1322 – 12/2003 edition
[3] ITU-T G.7041/Y.1303 – 12/2003 edition
[4] IEC 60825-1
[5] IEEE 802.3ae 2002 Edition
[6] SFP+ MSA - August 30th 2007
[7] SFF 8472 – Rev10.4 – January 30th 2009
[8] XFP MSA – Rev4.0 – Apr 13th 2004

Document
The object of this document is to provide you with information to operate the
modules in the PM C1001HC(-ETR) range via the on-board SNMP agent.

Ekinops PM C1001HC(-ETR) documentation


7 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Document Description

Description
The PM C1001HC(-ETR) range is a HW platform allowing transport of one client
port 10GbE LAN/STM-64/OC192 over one 10G line port with OTX transceiver.

The following table gives the different modules in this range:

Client
Reference Version Available options

PM C1001HC Standard 10GbE LAN All

PM C1001HC-ETR Extendre Temperature Range 10GbE LAN All


Table 1 PM C1001HC(-ETR) range description

The following options are available for the PM C1001HC(-ETR) family:


 Option 245: 10G Client SFP+ 850nm
 Option 256: 10G Client SFP+ 1310nm
 Option 280: 10G Client SFP+ 1550nm (40km)
 Option 315: OTX-VLH Tunable OTX
 Option 505: RMON and Performance Monitoring
 Option 900: 10M Ethernet DCC

Ekinops PM C1001HC(-ETR) documentation


8 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification

Chapter A Technical Specification

Ekinops PM C1001HC(-ETR) documentation


9 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1 Functional Description


A.1.1 General

The block diagram for the PM C1001HC(-ETR) is given in Figure 1.

The PM C1001HC(-ETR) is a bi-directional device. It therefore has different sections:

 Upstream Section: from one 10GbELAN/STM-64/OC192 optical input to 10 Gb/s


Ekinops wrapper optical output

 Downstream Section: from 10 Gb/s Ekinops wrapper optical input to one


10GbELAN/STM-64/OC192 optical output

 Common sections composed of :


 Controller block, providing interfacing to the C600HC/C200 chassis controller
board hosting the SNMP Agent.
 Power supplies: generates different internal power supplies from the -48V of the
C600HC/C200 chassis backplane
 Front panel LEDs indicating the status of the client and line ports, and the PM
C1001HC(-ETR) common functions

Ekinops PM C1001HC(-ETR) documentation


10 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

Data
Data Data Data Line
10GbELAN Loss Justification Framer Clock 10 Gb/s OTX
SFP+ 10 Gb/s 10GOUT
STM64/OC192
Clock of Sync WR Clock
and RD Clock
Serializer E/O
O/E Deserializer
Detection Mapper FEC Clock
encoder

loopback
TX Clocks Up REF Clock
Generation
Unit
Control Controller Block

Client
Bus (µProc, RAM
and Flash) Internal
Ref.
Clock

XFI Line Loopback

XFP Line Loopback


DCC OUT
10M Ethernet Ethernet
Switch
DCC IN

Dwn Ref Clock


-48 Volts A
GND A PWR RX Clock
Supply Generation
-48 Volts B Generation Unit
GND B
Ref Clock OC192 Ref Clock 10GbELAN

FEC Data
10GbELAN
Data 64B/66B Data Data
Decoder
SFP+ 10Gb/s Encoder De-Mapper 10 Gb/s OTX 10GIN
STM64/OC192 Clock
(10GbELAN
Clock Clock
O/E Serializer De-justification Clock Deserializer E/O
Line
Only)
De-Framer

Figure 1 PM C1001HC(-ETR) Block diagram

Ekinops PM C1001HC(-ETR) documentation


11 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.2 Upstream section


A.1.2.1 Input Ports interfacing
The upstream section has a configurable datacom (10GbE LAN) or telecom (OC192/STM-
64) client input.
Client physical interfacing is done through standard SFP+ modules.
When datacom protocol is selected, the upstream client port is 66B to 64B decoded. If
invalid 66B blocks are received, they are replaced by the /E/ control code.
The port configuration information (datacom or telecom protocol) is provided by the
controller block on a per port basis.
The following information is provided to the controller:
 SFP+ absence

 Loss of optical input signal

 Loss of synchronization on incoming signal:


 10 GbE LAN: Loss of 66B/64B decoder sync
 OC192/STM64: Loss of Frame

 Counting of incoming errors:


 10GbE LAN: MAC frames FCS errors counting
 OC192/STM64: B1 errors counting

 DDM information complying with document [7]

The following information is received from the controller block:


 OC192/STM64 mode or 10GbELAN mode

RMON (Remote Network Monitoring, option 505)


Remote Network Monitoring functionality is provided on the 10GbE incoming client port.
The following statistics are made available on a per port basis:

 Bytes counter:
Total number of octets of data (including those in bad packets) received on the
network (excluding framing bits but including FCS octets).

 Packet counters:
Total number of packets (including bad packets, broadcast packets, and multicast
packets) received

 CRC errors counter


Total number of packets received that had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad

Ekinops PM C1001HC(-ETR) documentation


12 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a
bad FCS with a non-integral number of octets (Alignment Error).

 Unicast packet counter


Total number of good packets received that were directed to a unicast address (LSB
of most significant byte of the destination MAC address equal to 0).

 Not-unicast packet counter


Total number of good packets received that were directed to the broadcast address
(MAC address equal to FF:FF:FF:FF:FF:FF:FF) or multicast address (LSB of most
significant byte of the destination MAC address equal to 1)

 Multicast packet counter


Total number of good packets received that were directed to a multicast address
(LSB of most significant byte of the destination MAC address equal to 1). Note that
this number does not include packets directed to the broadcast address

 Broadcast packet counter


Total number of good packets received that were directed to the broadcast address
(MAC address equal to FF:FF:FF:FF:FF:FF:FF). Note that this does not include
multicast packets

In the previous counters definitions,


Good packets are error-free packets that have a valid frame length. For example, on
Ethernet, good packets are error-free packets that are between 64 octets long and 1518
octets long. They follow the form defined in IEEE 802.3 section 3.2.all
Bad packets are packets that have proper framing and are therefore recognized as
packets, but contain errors within the packet or have an invalid length. For example, on
Ethernet, bad packets have a valid preamble and SFD, but have a bad CRC, or are either
shorter than 64 octets or longer than 1518 octets

A.1.2.2 Justification and Mapper


Incoming signals must be synchronized to the local clock prior of adaptation to long
distance transport.
Synchronisation is performed thanks to a justification process which can tolerate:
 on datacom input, ±100 ppm frequency deviation to the nominal 10 GbE LAN bit rate
 on telecom input, ±20 ppm frequency deviation to the nominal OC192/STM64 bit
rate

The mapper inserts an additional information: the Client Signal Fail indication
Client Signal Fail is a bit set in case one of the following conditions is present on the
incoming signal (see Figure 2)

 SFP+ not present


Ekinops PM C1001HC(-ETR) documentation
13 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

 Loss of incoming signal.


 Loss of synchronization on incoming signal
 Justification buffer overflow

All these contributors to client signal fail are configurable through the SNMP agent of
the C600HC/C200 chassis.

The following information is provided to the controller on a per port basis:


 Client Signal Fail asserted
 Justification buffer overload

Data
Line Data
Data Data
10GbELAN Loss of Justification Framer 10 Gb/s OTX
SFP+ 10 Gb/s Clock
10GOUT
STM64/OC192
Clock Sync WR Clock and RD Clock
Serializer E/O
O/E Deser
Detection Mapper FEC Clock

encoder

Alarms
reporting

Alarms Mask

Port 1 O CSF1
Client Signal Fail R
SW Command

Figure 2 Upstream Client Signal Fail assertion principle

A.1.2.3 Framer
The 10GbELAN or STM64/OC192 mapped client signals is inserted in an Ekinops
proprietary frame having a bit rate of 11.09 Gb/s.
BIP8 Monitoring parity is calculated over the entire frame and inserted in its corresponding
location in the outgoing signal.
The following information is provided to the controller on a per port basis:
 AIS inserted (test purposes)
 RDI inserted

Out of Band FEC encoding is performed and inserted in the Ekinops wrapper proprietary
frame. The line bit rate is 11.09 Gb/s.

10M DCC (option 900)


Option 900 allows inserting a 10Mb/s Ethernet data communication channel coming from
the Ethernet switch and transported in the proprietary Ekinops wrapper frame.

A.1.2.4 Line Optical Interfacing


Line optical interfacing is performed through OTX-VLH or XFP modules.

Ekinops PM C1001HC(-ETR) documentation


14 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

OTX-VLH modules are Ekinops designed optical interfaces which present the same optical
connector, as well as same management information as an XFP.
OTX-VLH module provides 80 kms DWDM tunable interface. Details on optical
characteristics can be found in section 0.
As opposed to XFP, OTX-VLH units are integrated in the PM C1001HC(-ETR) and
therefore can not be removed separately.

The following alarms can be read from the Line Optical Interface:
 Transmitter fault
 Transmitter CDR not locked
 Transmitter not ready
 DDM information complying with document [8]

The following controls can be sent to the OTX-VLH:

 Shut down optical transmitter


 OTX loop-back
 OTX Line loop-back

Ekinops PM C1001HC(-ETR) documentation


15 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.3 DownStream Section


A.1.3.1 Line Optical Interfacing
Line optical interfacing is performed through OTX-VLH or XFP modules.
OTX-VLH modules are Ekinops designed optical interfaces which present the same optical
connector, as well as same management information as an XFP.
OTX-VLH DWDM interface. Details be found in section 0.
As opposed to XFP, OTX-VLH units are not hot pluggable into the PM C1001HC(-ETR).

The following alarms can be read from the Line Optical Interface:
Loss of input signal
 Receiver CDR not locked
 Receiver not ready
 DDM information complying with document [8]

A.1.3.2 De-Framer
Line Ekinops wrapped signal is received from the line optical interface
Line Ekinops wrapped signal frame alignment is performed.
BIP8 Section Monitoring parity calculation is computed. When an FEC decoder is
provided, BIP8 parity calculation is the result of errors counted after correction. In that
case a counter is provided for indicating the number of errors before correction.
The payload containing 10GbELAN or STM64/OC192 is extracted and passed to the de-
mapper/de-justification block.
The following information is provided to the controller:
 Loss Of Frame on incoming signal
 AIS received
 RDI received
 BIP8 Monitoring errors counting

In Band FEC decoding is performed.


The following information is provided to the controller for the Ekinops wrapper incoming
signal:
 Number of errors counted before correction
 Status indicating if there are uncorrected errors

Ekinops PM C1001HC(-ETR) documentation


16 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.3.3 De-Mapper
The de-mapper extracts STM64/OC192 or 10 GbELAN data from the proprietary mapping
frame.
The de-justification process allows recovering the STM64/OC192 or 10GbELAN data
stream mapped at the far end.
The de-mapper has an associated PLL for each mode (OC192/STM64 or 10GbELAN) for
regenerating the far end incoming clock frequency, based on the information received from
the de-justification mechanism.

Client Signal Fail information is also extracted and reported to the controller block (see
Figure 3).
Error counting is performed on the de-mapped signals:
 10GbE LAN: MAC frames FCS errors counting
 OC192/STM64: B1 errors counting
And the result is reported to the controller block.
Under failure conditions, an output client AIS (CAIS) signal is inserted on the outgoing
client port.
The alarms leading to assertion of client AIS are:
 Loss of optical input signal
 Loss of Frame Ekinops wrapper input.
 AIS received on the Ekinops wrapper input.
 Incoming CSF detected on de-mapped client channel
 De-justification buffer overflow

The client AIS signal when asserted shuts down the client optical output.
The CAIS mechanism is described in Figure 4.
The following information is received from the control block:
 10GbELAN or STM64/OC192 configuration

The following information is provided to the control block on a per port basis:
 CSF received
 Client errors counting
 CAIS asserted

Ekinops PM C1001HC(-ETR) documentation


17 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

De FEC
64B/66B Data
10GbELAN Data Data
Mapper Data
Decoder
XFP 10Gb/s Encoder 10 Gb/s OTX 10GIN
STM64/OC192 Clock Clock & Clock
O/E Serializer (10GbELAN Clock
Deserializer E/O
De Line
Only)
justification De-Framer

CSF bit

3 f rames
conf irmation

CSF Alarm

Figure 3 Downstream CSF detection mechanism

De FEC
64B/66B Data
10GbELAN Data Data
Mapper Data
Decoder
XFP 10Gb/s Encoder 10 Gb/s OTX 10GIN
STM64/OC192 Clock Clock & Clock
O/E Serializer (10GbELAN Clock
Deserializer E/O
De Line
Only)
justification De-Framer
Alarms Mask

reporting
Alarms
OR

Client AIS
command

Figure 4 Downstream CAIS mechanism

A.1.3.4 64B/66B encoder and output port interfacing


64B/66B encoder is provided only when 10GbELAN client mode is selected. Errors which
can have happened on the transmission line may lead to words which are not recognized
by the encoder. Under such condition, they are replaced by the /E/ error code.

The data is serialized and converted to an optical signal by an SFP+ Transceiver.

The following information is provided to the control block:


 Optical transmitter failure
 DDM information complying with document [7].

The following configuration information is received from the control block on a per port
basis:
 Optical output shut-down
 10GbELAN or STM64/OC192 configuration

RMON (Remote Network Monitoring, option 505)


Remote Network Monitoring functionality is provided on the 10GbE outgoing client port.
The following statistics are made available on a per port basis:
Ekinops PM C1001HC(-ETR) documentation
18 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

 Bytes counter:
Total number of octets of data (including those in bad packets) received on the
network (excluding framing bits but including FCS octets).

 Packet counters:
Total number of packets (including bad packets, broadcast packets, and multicast
packets) received

 Unicast packet counter


Total number of good packets received that were directed to a unicast address (LSB
of most significant byte of the destination MAC address equal to 0).

 Not-unicast packet counter


Total number of good packets received that were directed to the broadcast address
(MAC address equal to FF:FF:FF:FF:FF:FF:FF) or multicast address (LSB of most
significant byte of the destination MAC address equal to 1)

 Multicast packet counter


Total number of good packets received that were directed to a multicast address
(LSB of most significant byte of the destination MAC address equal to 1). Note that
this number does not include packets directed to the broadcast address

 Broadcast packet counter


Total number of good packets received that were directed to the broadcast address
(MAC address equal to FF:FF:FF:FF:FF:FF:FF). Note that this does not include
multicast packets

In the previous counters definitions,


Good packets are error-free packets that have a valid frame length. For example, on
Ethernet, good packets are error-free packets that are between 64 octets long and 1518
octets long. They follow the form defined in IEEE 802.3 section 3.2.all
Bad packets are packets that have proper framing and are therefore recognized as
packets, but contain errors within the packet or have an invalid length. For example, on
Ethernet, bad packets have a valid preamble and SFD, but have a bad CRC, or are either
shorter than 64 octets or longer than 1518 octets

Ekinops PM C1001HC(-ETR) documentation


19 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.4 Maintenance Loop backs


A.1.4.1 OTX XFI loop back
As a test feature, an XFI loop back can be performed for maintenance operations, allowing
looping back the transmitted 10Gb/s signal on the downstream section. The description of
the data path in case of XFI loop back is found on Figure 5.

A.1.4.2 OTX Line loop back


As a test feature, a line loop back can be performed for maintenance operation, allowing
looping back the received 10 Gb/s signal on the upstream section. The clock and data
path in case of XFP line loop back is described on Figure 6

Warning
This loop back also loops the Ethernet traffic transported by the
DCC as is. This may cause troubles on the Ethernet network to
which DCC is connected

Ekinops PM C1001HC(-ETR) documentation


20 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

Ekinops PM C1001HC(-ETR) documentation


21 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

Data
Data Data Data Line
10GbELAN Loss Justification Framer Clock 10 Gb/s OTX
SFP+ 10 Gb/s 10GOUT
STM64/OC192
Clock of Sync WR Clock
and RD Clock
Serializer E/O
O/E Deserializer
Detection Mapper FEC Clock
encoder

loopback
TX Clocks Up REF Clock
Generation
Unit
Control Controller Block

Client
Bus (µProc, RAM
and Flash) Internal
Ref.
Clock

XFP Line Loopback


XFI Line Loopback
DCC OUT
10M Ethernet Ethernet
Switch
DCC IN

Dwn Ref Clock


-48 Volts A
GND A PWR RX Clock
Supply Generation
-48 Volts B Generation Unit
GND B
Ref Clock OC192 Ref Clock 10GbELAN

FEC Data
10GbELAN
Data 64B/66B Data Data
Decoder
SFP+ 10Gb/s Encoder De-Mapper 10 Gb/s OTX 10GIN
STM64/OC192 Clock
(10GbELAN
Clock Clock
O/E Serializer De-justification Clock Deserializer E/O
Line
Only)
De-Framer

Figure 5 Signal data path in OTX XFI loop-back operation

Ekinops PM C1001HC(-ETR) documentation


22 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

Data
Data Data Data Line
10GbELAN Loss Justification Framer Clock 10 Gb/s OTX
SFP+ 10 Gb/s 10GOUT
STM64/OC192
Clock of Sync WR Clock
and RD Clock
Serializer E/O
O/E Deserializer
Detection Mapper FEC Clock
encoder

loopback
TX Clocks Up REF Clock
Generation
Unit
Control Controller Block

Client
Bus (µProc, RAM
and Flash) Internal
Ref.
Clock

XFP Line Loopback


XFI Line Loopback
DCC OUT
10M Ethernet Ethernet
Switch
DCC IN

Dwn Ref Clock


-48 Volts A
GND A PWR RX Clock
Supply Generation
-48 Volts B Generation Unit
GND B
Ref Clock OC192 Ref Clock 10GbELAN

FEC Data
10GbELAN
Data 64B/66B Data Data
Decoder
SFP+ 10Gb/s Encoder De-Mapper 10 Gb/s OTX 10GIN
STM64/OC192 Clock
(10GbELAN
Clock Clock
O/E Serializer De-justification Clock Deserializer E/O
Line
Only)
De-Framer

Figure 6 Signal data path in OTX line loop-back operation

Ekinops PM C1001HC(-ETR) documentation


23 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.5 Clock Generation Unit


A.1.5.1 UpStream Clock Generation Unit
The UpStream Clock generation unit generates all internal clock signals required by the
upstream part of the PM C1001HC(-ETR). The reference clock is internal to the PM
C1001HC(-ETR) and has a stability of +/- 20 ppm.

The following information is made available to the controller block:


 Upstream clock multiplier unit not locked

A.1.5.2 DownStream Clock Generation Unit


The DownStream Clock generation unit generates all internal clock signals required by the
downstream part of the PM C1001HC(-ETR).
It generates in particular the 10GbELAN reference clocks which are fed to the de-mapper.
Under normal operation, this block is driven by the clock extracted from the de-justification
function. In case of failure of the incoming signal, this block is driven by the PM
C1001HC(-ETR) upstream reference clock.
The following information is made available to the controller block:

 DownStream clock recovery unit not locked

A.1.6 Controller Block


The controller block is composed of a microprocessor associated with Flash and RAM
memories.
The controller block collects information from different functional blocks and configures the
HW according to a configuration file received.
The raw information (alarms, monitoring, inventory …) generated by the HW are
processed by the microprocessor and delivered to the PM-MGNT as high level
consolidated data.
For the operation of the PM C1001HC(-ETR), refer to the Chapter B of the present
document

Ekinops PM C1001HC(-ETR) documentation


24 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.7 Out of Service and In Service states


A.1.7.1 Client port
An individual command is accessible to set the client port Out of Service.

When the client port is Out of Service, an Out of Service information is sent over the line
interface to inform the far end client port that the local client port is Out of Service. So each
client port provides the following additional information:
1. Local OS: The local client port is Out of Service
2. Distant OS: The far end client port is Out of Service.

An Out of Service client port has the following behaviour


3. The SFP+ Laser is be shut down
4. All the alarms of this client port are masked (except Local OS and Distant
OS).
5. All the counters of this client port are disabled (the invalid bit is set).
6. All the SFP+ measures of this client port are disabled (the value is set to 0).

When the client port is In Service, all the disabled features previously named are enabled
again. The alarms are unmasked and the Out of Service information is not sent anymore
over the line interface.

A.1.7.2 Line port


An individual command is accessible to set the line port Out of Service

Linked to the Out of Service state, the line port has the following additional information:
7. Local OS: The local line port is Out of Service.

An Out of Service line port has the following behaviour:


8. The OTX Laser is shut down
9. All the alarms of the line port are masked (except Local OS).
10. All the counters of the line port are disabled (the invalid bit is set).
11. All the OTX measures of the line port are disabled (the value is set to 0).
12. All the performance features of the line port are disabled (the invalid bit is set
to 0).

When the line port is In Service, all the disabled features previously named are enabled
again and the alarms are unmasked.

A.1.7.3 PM C1001HC(-ETR)
A command is accessible to set the complete PM C1001HC(-ETR) Out of Service. In that
case, all the client ports and the line port are set Out of Service as described in sections
A.1.7.1 and A.1.7.2.
Ekinops PM C1001HC(-ETR) documentation
25 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Functional Description)

A.1.8 Power Supplies


The power supply block generates from the received external -48 volts (PM C1001HC
version) or +24 volts (PM C1001HC-ETR version), the different internal supplies needed.

A.2 FEC performance


The following table gives the performance of the PM C1001HC(-ETR) FEC coupled to an
OTX-VLH.

PM C1001HC(-ETR)
OSNR @ 10-12 12 dB0.1nm
Table 2 FEC Performance

The OSNR values expressed in the above table corresponds to a residual Bit Error Rate of
10-12 after FEC correction.

Ekinops PM C1001HC(-ETR) documentation


26 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Interface Specifications)

A.3 Interface Specifications


A.3.1 Client Interfaces Optical Characteristics
Client interfacing is provided by SFP+ transceivers. The optical characteristics are
therefore given in the data sheet of the SFP+ plugged into the PM C1001HC(-ETR)
module.
SFP+ plugged in the PM C1001HC(-ETR) shall comply with the documents [6] and [7].

Ekinops PM C1001HC(-ETR) documentation


27 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Interface Specifications)

A.3.2 PM C1001HC(-ETR)-XO Line Interface characteristics


A.3.2.1 OTX-VLH (Tunable) Line Interface characteristics
The PM C1001HC(-ETR)-XO equipped with option 315 provides DWDM tunable optical
interfaces through the Ekinops Tunable OTX-VLH modules.
The optical characteristics for this interface are given in the following table:

Value
General Unit
Min Typ Max
Bit Rate nominal 9.95308 11.09 GHz
Line Coding NRZ
Optical path max attenuation
- - 26 dB
(@2000ps/nm)
Optical path min attenuation - 8 - dB
Max path penalty @2000ps/nm - - 2 dB
Max path penalty @-500ps/nm - - 3 dB
Transmitter Value
1528.77 - 1565.59 nm
DWDM Wavelength range (50 GHz grid)
191.5 - 196.1 THz
- 25 - + 25 pm
Centre wavelength tolerance (EOL)
- 2.5 - + 2.5 GHz
Pout (average value) +3 - +5 dBm
Extinction Ratio 10 - - dB
Receiver Value
Wavelength Range 1525 - 1570 nm
-12
Pinmax (BER @ 10 , average value, ER=10dB) - - -5 dBm
-12
Pinmin (sensitivity for BER @ 10 , average
- -27 -25 dBm
value, ER=10dB)
Receiver Reflectance -27 dB
Table 3 OTX-VLH Optical Characteristics

Ekinops PM C1001HC(-ETR) documentation


28 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Electrical and Environmental conditions)

A.4 Electrical and Environmental conditions


A.4.1 Power Consumption
PM C1001HC(-ETR) equipped with SFP+ complying to document [6] and OTX-VLH:
27 W typical

A.4.2 Ambient operating Temperature


The PM C1001HC is designed for operating in a chassis operated in an ambient
temperature range of 0°C to 50°C.

The PM C1001HC-ETR is designed for operating in a chassis operated in an ambient


temperature range of -40°C to 65°C.

A.4.3 Storage Temperature


In the storage temperature range of –40 to +85°C, the PM C1001HC(-ETR) has no
reliability deficiency.

Ekinops PM C1001HC(-ETR) documentation


29 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Front Panel Layout)

A.5 PM C1001HC(-ETR) Front Panel Layout


A.5.1 PM C1001HC
The PM C1001HC occupies one slot.
Client interface is an SFP+ cage capable of hosting standard SFP+ modules

PM C1001
Los
HC

SW
Fail
HW
S1 X1

Figure 7 PM C1001HC-O front panel layout

PM C1001
Los
HC

SW
Fail
HW
S1 X1

Figure 8 PM C1001HC-X front panel layout

PM C1001

Los Los
HC

SW
HW Fail Fail
S1 X1

Figure 9 PM C1001HC-O front panel layout (new!)


PM C1001

Los Los
HC

SW
HW Fail Fail
S1 X1

Figure 10 PM C1001HC-X front panel layout (new!)

Ekinops PM C1001HC(-ETR) documentation


30 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Technical Specification (Front Panel Layout)

A.5.2 PM C1001HC-ETR
The PM C1001HC-ETR occupies two slots.
Client interface is an SFP+ cage capable of hosting standard SFP+ modules

PM C1001
HC-ETR

SW Los Los

HW Fail Fail
S1 X1

Figure 11 PM C1001HC-ETR-O front panel layout

Ekinops PM C1001HC(-ETR) documentation


31 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual

Chapter B SNMP User Manual

Ekinops PM C1001HC(-ETR) documentation


33 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

B.1 General
PM-C1001HC(-ETR) is managed with the same standard mib as PM1001LH
Therefore the mib naming in this document is pm1001lh

B.2 Configuration
B.2.1 Access Configuration
Certain aspects of the line and client ports are user modifiable.
In the following procedures the modifications are indicated at bit level.
Take note of your SNMP manager’s requirements.

For example setting the bits 6, 3, 2 and 0 to 1 will yield the following values:

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Number
0 0 0 0 0 0 0 0 0 1 0 0 1 1 0 1 Binary
4D Hexadecimal
77 Decimal

B.2.1.1 Client Port Configuration


The table: pm1001lhCfgStartupTable

Location: \ekinops\modulePm1001lh\pm1001lhConfig\pm1001lhCfgStartup\

contains two objects for each client port:

pm1001lhCfgSystConfPortPortn
This allows the configuring of the initialisation of the ports.

and

pm1001lhCfgNetConfPortPortn
This allows the configuring of the protocol of the port.

Ekinops PM C1001HC(-ETR) documentation


34 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

The following table details the meaning of each bit as well as the default values:
pm1001lhCfgSystConfPortPortn
Bit Default value Bit Name Description
Bit 1-0 00 Reserved Set to Default value
Bit 2 0 Client_OOS “Client Port Out of Service” control start up value
Bit 3 0 Reserved Set to Default value
Bit 4 0 XFP_On_Off "SFP+ On OFF" control start up value
Bit 7-5 000 Reserved Set to Default value
Bit 15-8 00000000 Reserved Set to Default value
pm1001lhCfgNetConfPortPortn
Bit Default value Bit Name Description
Protocol Selection.
0111 : 10GbE LAN
Bit 3-0 0111 Protocol
1000 : OC192/STM64/10GBEWAN
other : Reserved
Bit 15-4 0x000 Reserved Set to Default value

Ekinops PM C1001HC(-ETR) documentation


35 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

B.2.1.2 Line Configuration


The object: pm1001lhCfgsynthTransLine,

Location: ...\ekinops\modulePm1001lh\pm1001lhConfig\pm1001lhCfgStartup\
pm1001lhtableLineStartup\

Allows to select the start-up service state of the line interface.

The following table details the meaning of each bit as well as the default values:
pm1001lhCfgsynthTransLine
Bit Default value Bit Name Description
Bit 5-0 000000 Reserved Set to Default value
Bit 6 0 Line_OOS “Line Port Out of Service” control start up value
Bit 15-7 0x0 Reserved Set to Default value

The object: pm1001lhCfglineOptions1,

Location: ...\ekinops\modulePm1001lh\pm1001lhConfig\pm1001lhCfgStartup\
pm1001lhtableLine\

Allows to enable/disable the Data Communication Channel interface.

The following table details the meaning of each bit as well as the default values:
pm1001lhCfglineOptions1
Bit Default value Bit Name Description
Bit 1-0 00 Reserved Set to Default value
Data Communication Channel interface:
Bit 2 1 DCC Enable 0: Disable
1: Enable
Bit 15-3 0x0 Reserved Set to Default value

Note
The object pm1001lhCfglineOptions1 is module type dependant.
Consult the table in the Description section to determine if it is
applicable or not.

Ekinops PM C1001HC(-ETR) documentation


36 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

B.2.1.3 Line Optical Interface Configuration


The table: pm1001lhCfgXfpTable

Location: \ekinops\modulePm1001lh\pm1001lhConfig\pm1001lhCfgStartup\

contains one object for each Line XFP/OTX interface:

pm1001lhCfgSystConfXfpPortn,
Allows the reconfiguring of the Line Optical Interface, XFP or OTX,
initialisation settings.

The following table details the meaning of each bit as well as the default values:

pm1001lhCfgSystConfXfpPortn
Bit Default value Bit Name Description
Bit 0 - 9 0000000000 Reserved Set to Default value
Bit 10 0 XFP/OTX on/off XFP/OTX on/off on initialisation
Bit 15 - 11 000000 Reserved Set to Default value

The table: pm1001lhCfgOtxtlhTable

Location: \ekinops\modulePm1001lh\pm1001lhConfig\pm1001lhCfgStartup\

contains two objects for each Line equipped with OTX TLH interface:

pm1001lhCfgLinePwrLaserPortn,
Allows the reconfiguring of the Line Optical output power (only with OTX
TLH).
and
pm1001lhCfgLineFCurrentPortn,
Allows the reconfiguring of the Line Optical wavelength (only with OTX TLH).

Ekinops PM C1001HC(-ETR) documentation


37 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

The following table details the meaning of each bit as well as the default values:

pm1001lhCfgLinePwrLaserPortn
Bit Default value Bit Name Description
Apply the following formula to define the value of this
parameter
Bit 15 - 0 0xC8 OTX TLH/VLH Output Power X  158
OutputPowerdBm 
10
Where X stands for the parameter value
pm1001lhCfgLineFCurrentPortn
Bit Default value Bit Name Description
Apply the following formula to define the value of this
parameter
299792458
Bit 15 - 0 0x1 OTX TLH/VLH wavelenght Wavelenghtnm 
193.1   X  32768   12.5 10 3 
Where X stands for the parameter value

Ekinops PM C1001HC(-ETR) documentation


38 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

B.2.2 How to modify the Configuration


The following procedure outlines how to modify any configuration. This can be
performed at any time, keeping in mind that the cold reset will affect the traffic.

Note
This is module type dependant. Consult the table in the
Description section to determine if it is applicable or not.

The following modifications may be achieved by using control


objects in:
...\ekinops\modulePm1001lh\pm1001lhcontrolsWrite\
However modifications made in this way are lost following a reset

The Line and Client configuration modification can be performed at


the same time and applied at the same time with one reset.

Traffic implications will depend on your choice of reset.

Procedure

- Ensure that the correct module is selected for management. Consult the object:
mgnt2GigmSelectedBoard

Location:…\ekinops\mgnt2\mgnt2SNMPAgentData\
mgnt2ModulesManagement\

-Change if necessary.

-Determine a value corresponding to the configuration profile you require.

-Perform an SNMP SET to write the value corresponding to the required


configuration profile into the SNMP agent.

-Perform a SET to “on” the object:


pm1001lhCfgWriteConfiguration.

Location: ...\ekinops\modulePm1001lh\pm1001lhConfig\

This will load the new configuration from the SNMP agent to the modules RAM.

-Transfer the new configuration into the module using the object:
pm1001lhCtrlConf2Flash1

Ekinops PM C1001HC(-ETR) documentation


39 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Software Management)

Location:
...\ekinops\modulePm1001lh\pm1001lhcontrolsWrite\pm1001lhCtrlOther\
pm1001lhCtrlconfMgnt1\

This saves the configuration of the module as user configuration in the flash
memory.

-Restart the module using a cold reset or by powering down/up to apply the
configuration modification. Reset information can be found in the Software
management section.

Note
At that point, user configuration becomes the start-up configuration
of the PM.

End

Ekinops PM C1001HC(-ETR) documentation


40 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3 Monitoring
B.3.1 Counters
There are a number of counters available to assist in the gathering of statistics.

Associated with each counter are an overload bit and an error bit.

The overload bit is set to “on” in the event of an overload of the counter and the
error bit is set to “on” in the event of an overload or error detected in a lower level.

If either is set (to “on”) the associated counter value is invalid. It is therefore
necessary that a method of polling is put in place at the manager in order to
manage the various counters efficiently.

In the event of the counter value becoming invalid, through overload or error,
control over the counters can be achieved with the objects:

pm1001lhCntCountersReset
Setting this object to “on” resets and restarts the counters.

pm1001lhCntCountersStop
Setting this object to “on” stops the counters.

Location: ...\ekinops\modulePm1001lh\pm1001lhcounters\

The following table gives the time to overload (in seconds) of the counters.
A full description of the available counters can be found in Appendix B.

Counter

pm1001lhCntupErrCntValuePortn

Client Incoming Error counter:


- 10 GbELAN: this counter is incremented each time an FCS error is detected on incoming client signal
- STM64/OC192: this counter is incremented each time a B1 error is detected on incoming client signal

Ekinops PM C1001HC(-ETR) documentation


41 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

Counter

pm1001lhCntdwErrCntValuePortn

Client Out going Error counter:


- 10 GbELAN: this counter is incremented each time an FCS error is detected on outgoing client signal
- STM64/OC192: this counter is incremented each time a B1 error is detected on outgoing client signal

pm1001lhCntdfrmErrCntValue

Line BIP error counter: This counter is incremented each time a line BIP error is detected on the ekinops wrapper input stream.

pm1001lhCntlineDfrmPrimErrCntValue

Line FEC error counter: This counter is incremented each time an error is corrected by the Forward Error Correction decoder.

pm1001lhCntdfrmTimCntValue

Line timer counter: This is the timing counter dedicated to the downstream deframer counters. It is incremented
every 121.9214 us

pm1001lhCntupTimCntValuePortn

Port upstream timer counter: This is the timing counter dedicated to the upstream access counters #n. It is
incremented every 121.9214 us

pm1001lhCntdwTimCntValuePortn

Port downstream timer counter: This is the timing counter dedicated to the downstream access counters. It is
incremented every 121.9214 us

Ekinops PM C1001HC(-ETR) documentation


42 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.2 Remote Monitoring Counters


There are 13 remote monitoring counters available to assist in the gathering of
statistics.

Associated with each counter are an overload bit and an error bit.

The overload bit is set to “on” in the event of an overload of the counter and the
error bit is set to “on” in the event of an overload or error detected in a lower level.

If either is set (to “on”) the associated counter value is invalid. It is therefore
necessary that a method of polling is put in place at the manager in order to
manage the various counters efficiently.

In the event of the counter value becoming invalid, through overload or error,
control over the counters can be achieved with the objects:

pm1001lhMonCountersReset
Setting this object to “on” resets and restarts the counters.

pm1001lhMonCountersStop
Setting this object to “on” stops the counters.

Location: ...\ekinops\modulePm1001lh\ pm1001lhMonitoring\pm1001lhRmon\


pm1001lhRmonOther\

The following table gives the time to overload (in seconds) of the counters.
A full description of the available counters can be found in Appendix B.

Counter
pm1001lhMonupRmonByteCntValuePortn
Bytes counter on Client input: This counter is increased each time a data byte is received on the client port

pm1001lhMonupRmonCrcErrorCntValuePortn
CRC Errors counter on Client input: This counter is increased each time a CRC error is detected on the client port

pm1001lhMonupRmonPacketsCntValuePortn
Packets counter on Client input: This counter is increased each time a packet is received on the client port

pm1001lhMonupRmonBroadcastCntValuePortn
Broadcast counter on Client input: This counter is increased each time a broadcast packet is received on the client port

pm1001lhMonupRmonMulticastCntValuePortn
Multicast counter on Client input: This counter is increased each time a Multicast packet is received on the client port

pm1001lhMonupRmonUnicastCntValuePortn
Unicast counter on Client input :This counter is increased each time a Unicast packet is received on client input

Ekinops PM C1001HC(-ETR) documentation


43 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

Counter
pm1001lhMonupRmonNonUnicastCntValuePortn
Non Unicast counter on Client Input :This counter is increased each time a Non Unicast packet is received on client
input

pm1001lhMondwRmonByteCntValuePortn
Bytes counter on Client output: This counter is increased each time a data byte is transmitted on the client port

pm1001lhMondwRmonPacketsCntValuePortn
Packets counter on Client output: This counter is increased each time a packet is transmitted on the client port

pm1001lhMondwRmonBroadcastCntValuePortn
Broadcast counter on Client output: This counter is increased each time a broadcast packet is transmitted on the client
port

pm1001lhMondwRmonMulticastCntValuePortn
Multicast counter on Client output: This counter is increased each time a Multicast packet is transmitted on the client
port

pm1001lhMondwRmonUnicastCntValuePortn
Unicast counter on Client output:This counter is increased each time a Unicast packet is transmitted on client input

pm1001lhMondwRmonNonUnicastCntValuePortn
Non Unicast counter on Client output:This counter is increased each time a Non Unicast packet is transmitted on client
input

Ekinops PM C1001HC(-ETR) documentation


44 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.3 Performance Monitoring


B.3.3.1 Performance Monitoring Synchronization
There are two objects dedicated to the synchronization of the Performance
Monitoring feature:

pm1001lhPerf15minSync
This object must be set every 15 minutes.

pm1001lhPerf24hSync
This object must be set every 24 hours.

Location: ...\ekinops\modulePm1001lh\ pm1001lhMonitoring\pm1001lhMonOther\


pm1001lhMonSync\

B.3.3.2 Performance Monitoring Time Stamp


There are six objects used to give the status of the performance synchronization:

pm1001lhPerfCurrent15MinElapsedTime
, gives the number seconds elapsed in the current 15-minutes period.

pm1001lhPerfCurrent24HoursElapsedTime
, gives the number seconds elapsed in the current 24-hours period.

pm1001lhPerf15MinShort
, indicates that the previous 15-minutes period lasts less than 890 seconds.

pm1001lhPerf15MinLong
, indicates that the previous 15-minutes period lasts more than 910 seconds.

pm1001lhPerf24HoursShort
, indicates that the previous 24-hours period lasts less than 86390seconds.

pm1001lhPerf24HoursLong
, indicates that the previous 24-hours period lasts more than 86410 seconds.

Location: ...\ekinops\modulePm1001lh\ pm1001lhMonitoring\pm1001lhMonOther\


pm1001lhMonTimeStamp\

Ekinops PM C1001HC(-ETR) documentation


45 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.3.3 Performance Monitoring Statistics


The performance monitoring feature of the PM C1001HC(-ETR) is available on client and
line interface.
The Line and the client port configured in STM64/OC192 performance monitoring statistics
are based on:
- Coding Violation
- Errored Seconds
- Severly Errored Seconds
- Severly Errored Framing Seconds
- Unavaible Seconds.

The client port configured in 10GbE LAN performance monitoring statistics are based on
RMON counter (see B.3.2 for details)

These parameters are provided for client and line port interface for the following periods:
- current 15-minutes
- previous 15-minutes
- current 24-hours
- previous 24-hours

The following table gives the root SNMP OID of each period for the line interface:
Period Root SNMP OID name
Current 15-minutes pm1001lhPerfTelecomLineCurrent15StatTable
Previous 15-minutes pm1001lhPerfTelecomLinePast15StatHistoryPort1Table
Current 24-hours pm1001lhPerfTelecomLineCurrent24StatTable
Previous 24-hours pm1001lhPerfTelecomLinePast24StatHistoryPort1Table

The following table gives the root SNMP OID of each period for the client interface
(OC192/STM64)
Period Root SNMP OID name
Current 15-minutes pm1001lhPerfTelecomClientCurrent15StatTable
Previous 15-minutes pm1001lhPerfTelecomClientPast15StatHistoryPort1Table
Current 24-hours pm1004PerfUpCurrent24CntTable
Previous 24-hours pm1001lhPerfTelecomClientPast24StatHistoryPort1Table

The following table gives the root SNMP OID of each period for the client interface (10GbE
LAN)
Period Root SNMP OID name
Current 15-minutes pm1001lhPerfDatacomClientCurrent15StatTable
Previous 15-minutes pm1001lhPerfDatacomClientPast15StatHistoryPort1Table
Current 24-hours pm1001lhPerfDatacomClientCurrent24StatTable
Previous 24-hours pm1001lhPerfDatacomClientPast24StatHistoryPort1Table

These OID are defining tables which contains a counter for each parameter.
Moreover, each parameter is linked to a Boolean object that indicates whether the
parameter is valid or not. (For instance, the invalid Boolean linked to the current 15-
minutes Errored Seconds parameter is pm1004PerfUpCurrent15CntInvEsPort)
Ekinops PM C1001HC(-ETR) documentation
46 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.4 Measures
In order to manage the various measurements available a polling mechanism is
required, thereby allowing the uploading of several physical parameters such as
optical transceiver temperature, optical input power, etc. provided by the DDM.

The DDM or Digital Diagnostic Monitoring in the SFP+ and OTX-VLH provides real-
time monitoring of voltage and temperature readings of each optical component,
together with thresholds and alarms.

A description of all the available measurements can be found in Appendix C: PM


C1001HC MIB description

The following describes the method of interpretation of the different types of


measurements:

B.3.4.1 Temperature
The object:
pm1001lhMesrclientModTempMeas,

Location:..\ekinops\modulePm1001lh\pm1001lhmeasures\pm1001lh8MesrClient\

This object gives the temperature value of the SFP+ plugged into client port, read
from the DDM (Digital Diagnostic Monitoring) (Unit = °C).

The following formula must be applied to the returned value in order to obtain the
actual temperature:

T (°C) = AV/256

Parameter Meaning Format


AV Article Value Unsigned word (16 bits)

For example:
The object pm1001lhMesrclientModTempMeas outputs the following:

1: pm1001lhMesrlineModTempMeas.0 (gauge) 11066

So applying the formula: T = 11066/256

Gives an actual temperature of: + 43.23°C

Ekinops PM C1001HC(-ETR) documentation


47 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.4.2 Bias
The object:
pm1001lhMesrclientBiasCurrentMeas,

Location:..\ekinops\modulePm1001lh\pm1001lhmeasures\pm1001lh8MesrClient\

This object gives the bias value of the SFP+ plugged into client port, read from the
DDM (Digital Diagnostic Monitoring) (Unit = mA).

The following formula must be applied to the returned value in order to obtain the
bias:

Bias(mA) = AV/500

Parameter Meaning Format


AV Article Value Unsigned word (16 bits)

For example:
The object pm1001lhMesrclientBiasCurrentMeas outputs the following:

1: pm1001lhMesrclientBiasCurrentMeas.0 (gauge) 17348

So applying the formula: Bias(mA) = 17348/500

Gives an actual value of: 34.696mA

Ekinops PM C1001HC(-ETR) documentation


48 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.4.3 Transmit Power


The object:
pm1001lhMesrclientTxPowerMeas,

Location:..\ekinops\modulePm1001lh\pm1001lhmeasures\pm1001lh8MesrClient\

This article gives the transmit power value of the SFP+ plugged into client port, read
from the DDM (Digital Diagnostic Monitoring) (Unit = dBm).

The actual Transmit Power in dBm or mW can be obtained by applying the following
formula to the returned value:

Tx_Pwr(mW) = AV/10000

Tx_Pwr(dBm) = 10xlog(AV/10000)

Parameter Meaning Format


AV Article Value Unsigned word (16 bits)
For example:
The object pm1001lhMesrclientTxPowerMeas outputs the following:

1: pm1001lhMesrlientTxPowerMeas.0 (gauge) 6293

So applying the formula: Tx_Pwr(mW) = 6293/10000

Gives an actual value of: 0.63mW

And applying the formula: Tx_Pwr(dBm) = 10xlog(6293/10000)

Gives an actual value of: -2.01dBm

Ekinops PM C1001HC(-ETR) documentation


49 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
SNMP User Manual (Monitoring)

B.3.4.4 Receive Power


The object:
pm1001lhMesrclientRxPowerMeas,

Location:..\ekinops\modulePm1001lh\pm1001lhmeasures\pm1001lh8MesrClient\

This article gives the receive power value of the SFP+ plugged into client port, read
from the DDM (Digital Diagnostic Monitoring) (Unit = dBm).

The actual Receive Power in dBm or mW can be obtained by applying the following
formula to the returned value:

Rx_Pwr(mW) = AV/10000

Rx_Pwr(dBm) = 10xlog(AV/10000)

Parameter Meaning Format


AV Article Value Unsigned word (16 bits)

For example:
The object pm1001lhMesrclientRxPowerMeas outputs the following:

1: pm1001lhMesrlientTxPowerMeas.0 (gauge) 30

So applying the formula: Rx_Pwr(mW) = 30/10000

Gives an actual value of: 0.003mW

And applying the formula: Rx_Pwr(dBm) = 10xlog(30/10000)

Gives an actual value of: -25.2dBm

Ekinops PM C1001HC(-ETR) documentation


50 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendixes

Appendixes

Ekinops PM C1001HC(-ETR) documentation


51 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix A : Laser Class

Appendix A: Laser Class


Laser Class Risks General Requirements

● Protective housing: may be


Considered safe to eye and Skin under all required.
1
reasonably foreseeable conditions of operation.

Ekinops PM C1001HC(-ETR) documentation


52 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
AppendixB : PM C1001HC Leds description

Appendix B: PM C1001HC(-ETR)Leds description

LED Status Condition


Green On Normal
Green Flashing Downloading
SW Red On Init.
Red Flashing Reboot
Orange Flashing PM s/w non operational
Green On Normal
HW
Red On Init./Reboot
Green Normal
Los
Red Loss of Frame
Green Normal
Fail
Red Line Failure
Green Normal
Access
Red Line fault

Ekinops PM C1001HC(-ETR) documentation


53 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Appendix C: PM C1001HC MIB description

OID Name Access Description


1.3.6.1.4.1.20044.10.2 pm1001lhalarms
1.3.6.1.4.1.20044.10.2.1 pm1001lhAlmOther
1.3.6.1.4.1.20044.10.2.1.1 pm1001lhAlmOtherNurg
1.3.6.1.4.1.20044.10.2.1.1.2 pm1001lhAlmsynthAlm2

PM configuration Save :This OID is


at 1 during the saving of a new
configuration table in the module
1.3.6.1.4.1.20044.10.2.1.1.2.1 pm1001lhAlmConfTableSave r
Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause>
<Alarmtype> <Polarity> (2)

Inventory Upload :This OID is at 1


during the uploading of PM inventory
1.3.6.1.4.1.20044.10.2.1.1.2.2 pm1001lhAlmInvUpload r information. <Condtype>
INV_UPLOAD <Probcause>
<Alarmtype> <Polarity> (2)

PM configuration Load :This OID is


at 1 during the loading of
configuration tables in the modules
1.3.6.1.4.1.20044.10.2.1.1.2.3 pm1001lhAlmConfTableLoad r
RAM. <Condtype>
CONF_TABLE_LOAD <Probcause>
<Alarmtype> <Polarity> (2)

Not used :This OID, when set,


indicates that alarm correlation is not
1.3.6.1.4.1.20044.10.2.1.1.2.4 pm1001lhAlmCorrelatOff r being performed. <Condtype>
CORRELAT_OFF <Probcause>
<Alarmtype> <Polarity> (2)

Maintenance Mode :This OID


indicates that the PM is in
maintenance mode. <Help> This
alarm indicates that the maintenance
1.3.6.1.4.1.20044.10.2.1.1.2.5 pm1001lhAlmMaintenanceOn r
mode is enabled on the PM
<Condtype> MAINTENANCE_ON
<Probcause> <Alarmtype>
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.1.2 pm1001lhAlmOtherUrg
1.3.6.1.4.1.20044.10.2.1.2.194 pm1001lhAlmmodInitFailLevel2

Led Fail :This OID indicates that Led


register has not been correctly
initalized <Help> This alarm
indicates if the module LEDs are
1.3.6.1.4.1.20044.10.2.1.2.194.1 pm1001lhAlmLedFail r correctly initialized <Condtype>
LED_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

Ekinops PM C1001HC(-ETR) documentation


54 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Next Cold Boot Forced :This OID


indicates that the next Reset will be
forced Cold <Help> This alarm
indicates that the next reset of the
module will be forced to cold reset
1.3.6.1.4.1.20044.10.2.1.2.194.2 pm1001lhAlmNextColdBootForced r
<Condtype>
NEXT_COLD_BOOT_FORCED
<Probcause>
informationalStatus(1000)
<Alarmtype> other (1) <Polarity> (2)

Boot Undone :This OID indicates


that the boot has not been correctly
achieved <Help> This alarm
indicates if the module has correctly
1.3.6.1.4.1.20044.10.2.1.2.194.3 pm1001lhAlmBootUndone r
boot <Condtype> BOOT_UNDONE
<Probcause> softwareError (47)
<Alarmtype> processingErrorAlarm
(4) <Polarity> (2)

Reset HW Init Fail :This OID


indicates that the HW intialization
has caused unknown intial
conditions <Help> This alarm
indicates if the HW has been
1.3.6.1.4.1.20044.10.2.1.2.194.4 pm1001lhAlmResetHwInitFail r
correctly initialized <Condtype>
RESET_HW_INIT_FAIL
<Probcause> softwareError (47)
<Alarmtype> processingErrorAlarm
(4) <Polarity> (2)

SW Init Fail :This OID indicates that


the SW intialization has caused
unknown intial conditions <Help>
This alarm indicates if the SW
1.3.6.1.4.1.20044.10.2.1.2.194.5 pm1001lhAlmSwInitFail r module is correctly initialized
<Condtype> SW_INIT_FAIL
<Probcause> softwareError (47)
<Alarmtype> processingErrorAlarm
(4) <Polarity> (2)

1.3.6.1.4.1.20044.10.2.1.2.195 pm1001lhAlmmodInitFailLevel3

GW Ident Fail :This OID indicates


that GW identification has not been
read <Help> This alarm indicates if
the GW has been correctly identified
1.3.6.1.4.1.20044.10.2.1.2.195.1 pm1001lhAlmGwIdentFail r
<Condtype> GW_IDENT_FAIL
<Probcause> softwareError (47)
<Alarmtype> processingErrorAlarm
(4) <Polarity> (2)

OBM Type Read Fail :This OID


indicates that OBM type has not
been recognized <Help> This alarm
indicates if the OBM board has been
1.3.6.1.4.1.20044.10.2.1.2.195.2 pm1001lhAlmObmTypeReadFail r correctly identified <Condtype>
OBM_TYPE_READ_FAIL
<Probcause> softwareError (47)
<Alarmtype> processingErrorAlarm
(4) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


55 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Init Module Fail :This OID indicates


that the Module has not been
correctly initialized <Help> This
alarm indicates if the SW module is
1.3.6.1.4.1.20044.10.2.1.2.195.3 pm1001lhAlmInitModuleFail r correctly initialized <Condtype>
INIT_MODULE_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

XFP1 Init Fail :This OID indicates


that the XFP has not been correctly
initialized <Help> This alarm
indicates if the line transceiver 1 is
1.3.6.1.4.1.20044.10.2.1.2.195.5 pm1001lhAlmXfp1InitFail r correctly initialized <Condtype>
XFP1_INIT_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

XFP2 Init Fail :This OID indicates


that the XFP has not been correctly
initialized <Help> This alarm
indicates if the line transceiver 2 is
1.3.6.1.4.1.20044.10.2.1.2.195.6 pm1001lhAlmXfp2InitFail r correctly initialized <Condtype>
XFP2_INIT_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

Line1 Init Fail :This OID indicates


that the Line registersvsubset has
not been correctly initialized <Help>
This alarm indicates if the line port is
1.3.6.1.4.1.20044.10.2.1.2.195.7 pm1001lhAlmLine1InitFail r correctly initialized <Condtype>
LINE1_INIT_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

Client1 Init Fail :This OID indicates


that Client 1 registers subset has not
been correctly initialized <Help>
This alarm indicates if the client port
1.3.6.1.4.1.20044.10.2.1.2.195.9 pm1001lhAlmClient1InitFail r is correctly initialized <Condtype>
CLIENT1_INIT_FAIL <Probcause>
softwareError (47) <Alarmtype>
processingErrorAlarm (4) <Polarity>
(2)

1.3.6.1.4.1.20044.10.2.1.3 pm1001lhAlmOtherCrit
1.3.6.1.4.1.20044.10.2.1.3.0 pm1001lhAlmsynthAlm0

Module Failure :This OID is set on


detection of a failure originating from
1.3.6.1.4.1.20044.10.2.1.3.0.9 pm1001lhAlmModGlobFail r the PM <Condtype>
MOD_GLOB_FAIL <Probcause>
<Alarmtype> <Polarity> (2)

Fuse A fail :This OID indicates that


the fuse of the power input A is in fail
condition <Help> Status of the
1.3.6.1.4.1.20044.10.2.1.3.0.15 pm1001lhAlmDefFuseA r Fuse A <Condtype> DEF_FUSE_A
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


56 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Fuse B Fail :This OID indicates that


the fuse of the power input B is in fail
condition <Help> Status of the
1.3.6.1.4.1.20044.10.2.1.3.0.16 pm1001lhAlmDefFuseB r Fuse B <Condtype> DEF_FUSE_B
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.2 pm1001lhAlmClient
1.3.6.1.4.1.20044.10.2.2.1 pm1001lhAlmClientNurg
1.3.6.1.4.1.20044.10.2.2.1.48 pm1001lhAlmclientXfpWarnings

Client Optical Tx Pwr Low warning


:Warning indicating that the
XFP/OTX transmitter transmitter
output power is lower than the
threshold value written in the
1.3.6.1.4.1.20044.10.2.2.1.48.1 pm1001lhAlmClientTxPowerLowWarning r
XFP/OTX EEPROM <Condtype>
CLIENT_TX_POWER_LOW_WARN
ING <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Optical Tx Pwr High warning


:Warning indicating that the
XFP/OTX transmitter transmitter
output power is higher than the
threshold value written in the XFP
1.3.6.1.4.1.20044.10.2.2.1.48.2 pm1001lhAlmClientTxPowerHighWarning r
EEPROM <Condtype>
CLIENT_TX_POWER_HIGH_WARN
ING <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Transceiver Bias Low warning


:Warning indicating that the
XFP/OTX transmitter laser bias
current is lower than the threshold
value written in the XFP/OTX
1.3.6.1.4.1.20044.10.2.2.1.48.3 pm1001lhAlmClientTxBiasLowWarning r
EEPROM <Condtype>
CLIENT_TX_BIAS_LOW_WARNIN
G <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Transceiver Bias High warning


:Warning indicating that the
XFP/OTX transmitter laser bias
current is higher than the threshold
value written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.2.1.48.4 pm1001lhAlmClientTxBiasHighWarning r
<Condtype>
CLIENT_TX_BIAS_HIGH_WARNIN
G <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Transceiver Temp Low


warning :Warning indicating that the
XFP/OTX temperature is lower than
the threshold value written in the
XFP/OTX EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.1.48.7 pm1001lhAlmClientTempLowWarning r
CLIENT_TEMP_LOW_WARNING
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


57 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Transceiver Temp High


warning :Warning indicating that the
XFP/OTX temperature is higher than
the threshold value written in the
XFP EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.1.48.8 pm1001lhAlmClientTempHighWarning r
CLIENT_TEMP_HIGH_WARNING
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Optical Rx Pwr Low warning


:Warning indicating that the XFP
received optical power is lower than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.2.1.48.15 pm1001lhAlmClientRxPowerLowWarning r XFP EEPROM <Condtype>
CLIENT_RX_POWER_LOW_WARN
ING <Probcause> receiveFailure
(41) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Optical Rx Pwr High warning


:Warning indicating that the XFP
received optical power is higher than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.2.1.48.16 pm1001lhAlmClientRxPowerHighWarning r XFP EEPROM <Condtype>
CLIENT_RX_POWER_HIGH_WAR
NING <Probcause> receiveFailure
(41) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.2 pm1001lhAlmClientUrg
1.3.6.1.4.1.20044.10.2.2.2.32 pm1001lhAlmclientXfpAlarm1

Client Optical Tx Power Low :Alarm


indicating that the XFP/OTX
transmitter transmitter output power
is lower than the threshold value
written in the XFP/OTX EEPROM
1.3.6.1.4.1.20044.10.2.2.2.32.1 pm1001lhAlmClientTxPowerLowAlarm r
<Condtype>
CLIENT_TX_POWER_LOW_ALAR
M <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Optical Tx Power High :Alarm


indicating that the XFP/OTX
transmitter transmitter output power
is higher than the threshold value
written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.2.2.32.2 pm1001lhAlmClientTxPowerHighAlarm r
<Condtype>
CLIENT_TX_POWER_HIGH_ALAR
M <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Transceiver Bias Low :Alarm


indicating that the XFP/OTX
transmitter laser bias current is lower
than the threshold value written in
1.3.6.1.4.1.20044.10.2.2.2.32.3 pm1001lhAlmClientTxBiasLowAlarm r the XFP/OTX EEPROM <Condtype>
CLIENT_TX_BIAS_LOW_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


58 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Transceiver Bias High :Alarm


indicating that the XFP/OTX
transmitter laser bias current is
higher than the threshold value
written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.2.2.32.4 pm1001lhAlmClientTxBiasHighAlarm r
<Condtype>
CLIENT_TX_BIAS_HIGH_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Transceiver Temp Low :Alarm


indicating that the XFP/OTX
temperature is lower than the
threshold value written in the
XFP/OTX EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.32.7 pm1001lhAlmClientTempLowAlarm r
CLIENT_TEMP_LOW_ALARM
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Transceiver Temp High :Alarm


indicating that the XFP/OTX
temperature is higher than the
threshold value written in the XFP
EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.32.8 pm1001lhAlmClientTempHighAlarm r
CLIENT_TEMP_HIGH_ALARM
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Optical Rx Power Low :Alarm


indicating that the XFP received
optical power is lower than the
threshold value written in the XFP
1.3.6.1.4.1.20044.10.2.2.2.32.15 pm1001lhAlmClientRxPowerLowAlarm r EEPROM <Condtype>
CLIENT_RX_POWER_LOW_ALAR
M <Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Optical Rx Power High :Alarm


indicating that the XFP received
optical power is higher than the
threshold value written in the XFP
1.3.6.1.4.1.20044.10.2.2.2.32.16 pm1001lhAlmClientRxPowerHighAlarm r EEPROM <Condtype>
CLIENT_RX_POWER_HIGH_ALAR
M <Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.2.64 pm1001lhAlmclientXfpSupplyAlarm

VEE5 Power Supply Low :Alarm


indicating the XFP/OTX VEE5 power
supply is lower than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.1 pm1001lhAlmClientVee5LowAlarm r
CLIENT_VEE5_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


59 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VEE5 Power Supply High :Alarm


indicating the XFP/OTX VEE5 power
supply is higher than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.2 pm1001lhAlmClientVee5HighAlarm r
CLIENT_VEE5_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply Low :Alarm


indicating the XFP/OTX VCC2 power
supply is lower than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.3 pm1001lhAlmClientVcc2LowAlarm r
CLIENT_VCC2_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply High :Alarm


indicating the XFP/OTX VCC2 power
supply is higher than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.4 pm1001lhAlmClientVcc2HighAlarm r
CLIENT_VCC2_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply Low :Alarm


indicating the XFP/OTX VCC3 power
supply is lower than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.5 pm1001lhAlmClientVcc3LowAlarm r
CLIENT_VCC3_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply High :Alarm


indicating the XFP/OTX VCC3 power
supply is higher than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.6 pm1001lhAlmClientVcc3HighAlarm r
CLIENT_VCC3_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply Low :Alarm


indicating the XFP/OTX VCC5 power
supply is lower than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.7 pm1001lhAlmClientVcc5LowAlarm r
CLIENT_VCC5_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply High :Alarm


indicating the XFP/OTX VCC5 power
supply is higher than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.2.2.64.8 pm1001lhAlmClientVcc5HighAlarm r
CLIENT_VCC5_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


60 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VEE5 Power Supply Low Warning


:Warning indicating the XFP/OTX
VEE5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.9 pm1001lhAlmClientVee5LowWarning r <Condtype>
CLIENT_VEE5_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VEE5 Power Supply High Warning


:Warning indicating the XFP/OTX
VEE5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.10 pm1001lhAlmClientVee5HighWarning r <Condtype>
CLIENT_VEE5_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC2 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.11 pm1001lhAlmClientVcc2LowWarning r <Condtype>
CLIENT_VCC2_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC2 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.12 pm1001lhAlmClientVcc2HighWarning r <Condtype>
CLIENT_VCC2_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC3 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.13 pm1001lhAlmClientVcc3LowWarning r <Condtype>
CLIENT_VCC3_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC3 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.14 pm1001lhAlmClientVcc3HighWarning r <Condtype>
CLIENT_VCC3_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


61 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VCC5 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.15 pm1001lhAlmClientVcc5LowWarning r <Condtype>
CLIENT_VCC5_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.2.2.64.16 pm1001lhAlmClientVcc5HighWarning r <Condtype>
CLIENT_VCC5_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.3 pm1001lhAlmClientCrit
1.3.6.1.4.1.20044.10.2.2.3.8 pm1001lhAlmsynthAlmPort

Client XFP not plugged :This OID


indicates that the XFP module is not
present in the client port. <Help>
This alarm indicates if the client
transceiver is present. <Condtype>
1.3.6.1.4.1.20044.10.2.2.3.8.1 pm1001lhAlmClientXfpAbsent r
CLIENT_XFP_ABSENT
<Probcause>
inputOutputDeviceError (24)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2) <Event> ObjectCDINV

Client Optical Module ready :This


OID indicates that the client optical
interface (XFP or OTX) is not
operational. <Help> This status
indicates if the client transceiver has
1.3.6.1.4.1.20044.10.2.2.3.8.2 pm1001lhAlmClientDdmAbsent r
been correctly initialized <Condtype>
CLIENT_DDM_ABSENT
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client HW Fail :This OID indicates a


failure on client port, most probably
1.3.6.1.4.1.20044.10.2.2.3.8.4 pm1001lhAlmClientHwFail r caused by a HW issue. <Condtype>
CLIENT_HW_FAIL <Probcause>
<Alarmtype> <Polarity> (2)

Client XFP optical TX ON :This OID


indicates the Client XFP transmitter
output is ON. <Help> This status
indicates if the client transceiver
1.3.6.1.4.1.20044.10.2.2.3.8.5 pm1001lhAlmClientDwLsd r
laser is ON or OFF <Condtype>
CLIENT_DW_LSD <Probcause>
other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


62 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Local Client port In Service :This


OID indicates that the local Client
port is In Service (1) or Out of
Service (2) <Help> This status
1.3.6.1.4.1.20044.10.2.2.3.8.6 pm1001lhAlmClientLocalOos r indicates if the local client port is in
service <Condtype>
CLIENT_LOCAL_OOS <Probcause>
informationalStatus(1000)
<Alarmtype> other (1) <Polarity> (2)

Client AIS inserted :This OID


indicates a CAIS has been inserted
on the output client port. <Help>
This status indicates if a Client Alarm
1.3.6.1.4.1.20044.10.2.2.3.8.8 pm1001lhAlmClientDwCais r Indication Signal is currently inserted
on the client interface <Condtype>
CLIENT_DW_CAIS <Probcause>
informationalStatus(1000)
<Alarmtype> other (1) <Polarity> (2)

Warning on Client XFP DDM :This


OID indicates a warning is being
received from the Client XFP DDM
<Help> This alarm indicates if a
1.3.6.1.4.1.20044.10.2.2.3.8.9 pm1001lhAlmClientXfpDdmWarning r DDM Warning has been detected on
the client transceiver <Condtype>
CLIENT_XFP_DDM_WARNING
<Probcause> <Alarmtype>
<Polarity> (2)

Alarm on Client XFP DDM :This OID


indicates an alarm is being received
from the Client XFP DDM <Help>
This alarm indicates if a DDM Alarm
1.3.6.1.4.1.20044.10.2.2.3.8.10 pm1001lhAlmClientXfpDdmAlm r has been detected on the client
transceiver <Condtype>
CLIENT_XFP_DDM_ALM
<Probcause> <Alarmtype>
<Polarity> (2)

Client Access Fail :This OID


indicates a failure on the Client port
1.3.6.1.4.1.20044.10.2.2.3.8.12 pm1001lhAlmClientFail r <Condtype> CLIENT_FAIL
<Probcause> <Alarmtype>
<Polarity> (2)

Client Signal Fail inserted :This OID


indicates a CSF has been inserted in
the upstream client port. <Help>
This status indicates if a Client
1.3.6.1.4.1.20044.10.2.2.3.8.16 pm1001lhAlmClientUpCsf r Signal Fail is currently inserted on
the line signal for this client port
<Condtype> CLIENT_UP_CSF
<Probcause> <Alarmtype>
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.3.16 pm1001lhAlmclientAccessioAlm

Ekinops PM C1001HC(-ETR) documentation


63 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client XFP Tx Failed :This OID


indicates that the transmitter fails for
the XFP plugged into the client port
(this alarm reports the transmitter
1.3.6.1.4.1.20044.10.2.2.3.16.1 pm1001lhAlmClientDwLasFail r failure alarm generated by the XFPs)
<Condtype>
CLIENT_DW_LAS_FAIL
<Probcause> <Alarmtype>
<Polarity> (2)

Loss of Optical signal on Client :This


OID indicates that no signal is
present on the XFP of the client port
<Help> This alarm indicates if an
1.3.6.1.4.1.20044.10.2.2.3.16.4 pm1001lhAlmClientUpLos r optical signal is detected on the
client transceiver input <Condtype>
CLIENT_UP_LOS <Probcause>
receiveFailure (41) <Alarmtype>
physicalViolation (9) <Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.3.40 pm1001lhAlmclientXfpAlarm2

Client Optical Module not ready :This


OID indicates that the module is
unable to determine correct data.
<Help> This alarm indicates if the
1.3.6.1.4.1.20044.10.2.2.3.40.2 pm1001lhAlmClientModNr r
Client transceiver is ready
<Condtype> CLIENT_MOD_NR
<Probcause> <Alarmtype>
<Polarity> (2)

Client Optical Rx CDR unlocked


:This OID indicates that a loss of
lock on the receiving side CDR has
been detected <Help> This alarm
indicates if the Rx CDR is locked in
1.3.6.1.4.1.20044.10.2.2.3.40.3 pm1001lhAlmClientRxCdrNotLocked1 r
the Client transceiver <Condtype>
CLIENT_RX_CDR_NOT_LOCKED1
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Optical Rx not ready :This OID


indicates that a condition has arisen
leading to invalid data on the
receiving side. <Help> This alarm
1.3.6.1.4.1.20044.10.2.2.3.40.5 pm1001lhAlmClientRxNr r
indicates if the Rx part of the Client
transceiver is ready <Condtype>
CLIENT_RX_NR <Probcause>
<Alarmtype> <Polarity> (2)

Client Optical Tx CDR unlocked


:This OID indicates a loss of lock on
the transmitting side CDR has been
detected. <Help> This alarm
indicates if the Tx CDR is locked in
1.3.6.1.4.1.20044.10.2.2.3.40.6 pm1001lhAlmClientTxCdrNotLocked1 r
the Client transceiver <Condtype>
CLIENT_TX_CDR_NOT_LOCKED1
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


64 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Optical Tx Failure :This OID


indicates a fault condition on the
laser detected by the safety syste
<Help> This alarm indicates if the
1.3.6.1.4.1.20044.10.2.2.3.40.7 pm1001lhAlmClientTxFault r laser of the Client transceiver is in
fail condition <Condtype>
CLIENT_TX_FAULT <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Client Optical Tx not ready :This OID


indicates a condition has arisen
leading to invalid data on the
transmitting side <Help> This alarm
1.3.6.1.4.1.20044.10.2.2.3.40.8 pm1001lhAlmClientTxNr r
indicates if the Tx part of the Client
transceiver is ready <Condtype>
CLIENT_TX_NR <Probcause>
<Alarmtype> <Polarity> (2)

Client Optical Tx Wavelength


unlocked :This OID indicates that the
wavelength error is exceeding the
manufacturer tolerance <Help>
This alarm indicates if the
1.3.6.1.4.1.20044.10.2.2.3.40.14 pm1001lhAlmClientWavelengthUnlocked r wavelenght of the Client transceiver
is locked <Condtype>
CLIENT_WAVELENGTH_UNLOCK
ED <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Client Optical Tx Temp Regul. Failed


:This OID indicates a failure on the
TEC module <Help> This alarm
indicates if the TEC of the Client
1.3.6.1.4.1.20044.10.2.2.3.40.15 pm1001lhAlmClientTecFault r transceiver is in fail condition
<Condtype> CLIENT_TEC_FAULT
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Client Rx Photodiode Power Failed


:This OID indicates a failure on the
APD power supply <Help> This
alarm indicates if the APD power
supply is in fail condition
1.3.6.1.4.1.20044.10.2.2.3.40.16 pm1001lhAlmClientApdSupplyFault r
<Condtype>
CLIENT_APD_SUPPLY_FAULT
<Probcause> receiverFailure (42)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.2.3.72 pm1001lhAlmclientMapperDeAlm

Client Loss of Synchronisation :This


OID indicates the upstream client
input port is in Loss of
Synchronization <Help> This
alarms indicates if the input client
1.3.6.1.4.1.20044.10.2.2.3.72.1 pm1001lhAlmClientUpAccOos r signal is correctly synchronized with
the decoder <Condtype>
CLIENT_UP_ACC_OOS
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation (7)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


65 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Upstream buffer overload


:This OID indicates that the rate
adaptation buffer for client port is in
overload. <Condtype>
1.3.6.1.4.1.20044.10.2.2.3.72.10 pm1001lhAlmClientUpBufferOvl r
CLIENT_UP_BUFFER_OVL
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation (7)
<Polarity> (2)

Client Signal Fail detected :This OID


indicates that a CSF has been
detected on client port in the
downstream direction <Help> This
alarm indicates if a Client Signal Fail
1.3.6.1.4.1.20044.10.2.2.3.72.11 pm1001lhAlmClientDwCsfDet r has been detected in the incoming
line frame for this client port
<Condtype>
CLIENT_DW_CSF_DET
<Probcause> <Alarmtype>
<Polarity> (2)

Client Downstream buffer overload


:This OID indicates that the de-
mapper buffer for client port is in
overload. <Condtype>
1.3.6.1.4.1.20044.10.2.2.3.72.14 pm1001lhAlmClientDwBufferOvl r
CLIENT_DW_BUFFER_OVL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

1.3.6.1.4.1.20044.10.2.3 pm1001lhAlmLine
1.3.6.1.4.1.20044.10.2.3.1 pm1001lhAlmLineNurg

Line S1 Extracted Value :This OID


gives the value of S1 extracted from
the overhead of the line received
1.3.6.1.4.1.20044.10.2.3.1.130 pm1001lhAlmdownS1Line r
signal <Condtype> DW_S1_8
<Probcause> <Alarmtype>
<Polarity> (2)

Line K1 Extracted Value :This OID


gives the value of K1 extracted from
the overhead of the line received
1.3.6.1.4.1.20044.10.2.3.1.131 pm1001lhAlmdownK1Line r
signal <Condtype> DW_K1_8
<Probcause> <Alarmtype>
<Polarity> (2)

Line K2 Extracted Value :This OID


gives the value of K2 extracted from
the overhead of the line received
1.3.6.1.4.1.20044.10.2.3.1.132 pm1001lhAlmdownK2Line r
signal <Condtype> DW_K2_8
<Probcause> <Alarmtype>
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.1.209 pm1001lhAlmlineXfpWarnings

Line Optical Tx Power Low warning


:Warning indicating that the
XFP/OTX transmitter transmitter
output power is lower than the
threshold value written in the
1.3.6.1.4.1.20044.10.2.3.1.209.1 pm1001lhAlmLineTxPowerLowWarning r
XFP/OTX EEPROM <Condtype>
LINE_TX_POWER_LOW_WARNIN
G <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


66 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Optical Tx Power High warning


:Warning indicating that the
XFP/OTX transmitter transmitter
output power is higher than the
threshold value written in the XFP
1.3.6.1.4.1.20044.10.2.3.1.209.2 pm1001lhAlmLineTxPowerHighWarning r
EEPROM <Condtype>
LINE_TX_POWER_HIGH_WARNIN
G <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Line Transceiver Bias Low warning


:Warning indicating that the
XFP/OTX transmitter laser bias
current is lower than the threshold
value written in the XFP/OTX
1.3.6.1.4.1.20044.10.2.3.1.209.3 pm1001lhAlmLineTxBiasLowWarning r
EEPROM <Condtype>
LINE_TX_BIAS_LOW_WARNING
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Bias High warning


:Warning indicating that the
XFP/OTX transmitter laser bias
current is higher than the threshold
value written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.3.1.209.4 pm1001lhAlmLineTxBiasHighWarning r
<Condtype>
LINE_TX_BIAS_HIGH_WARNING
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Temp Low warning


:Warning indicating that the
XFP/OTX temperature is lower than
the threshold value written in the
XFP/OTX EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.3.1.209.7 pm1001lhAlmLineTempLowWarning r
LINE_TEMP_LOW_WARNING
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Temp High warning


:Warning indicating that the
XFP/OTX temperature is higher than
the threshold value written in the
XFP EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.3.1.209.8 pm1001lhAlmLineTempHighWarning r
LINE_TEMP_HIGH_WARNING
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Optical Rx Power Low warning


:Warning indicating that the XFP
received optical power is lower than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.3.1.209.15 pm1001lhAlmLineRxPowerLowWarning r XFP EEPROM <Condtype>
LINE_RX_POWER_LOW_WARNIN
G <Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


67 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Optical Rx Power High warning


:Warning indicating that the XFP
received optical power is higher than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.3.1.209.16 pm1001lhAlmLineRxPowerHighWarning r XFP EEPROM <Condtype>
LINE_RX_POWER_HIGH_WARNIN
G <Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.1.225 pm1001lhAlmlineOtxTlhWarnings

Line modulator aging high warning


:Warning indicating the Line OTX
TLH modulator aging is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.1.225.5 pm1001lhAlmLineModulatorAgingHighWarning r <Condtype>
LINE_MODULATOR_AGING_HIGH
_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Line OTX TLH aging high warning


:Warning indicating the Line OTX
TLH aging is higher than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.1.225.6 pm1001lhAlmLineAgingHighWarning r <Condtype>
LINE_AGING_HIGH_WARNING
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Freq. deviation high warning


:Warning indicating the Line OTX
TLH frequency deviation is higher
than the threshold written in the
1.3.6.1.4.1.20044.10.2.3.1.225.12 pm1001lhAlmLineFreqDevHighWarning r EEPROM <Condtype>
LINE_FREQ_DEV_HIGH_WARNIN
G <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Line Laser Temp. High warning


:Warning indicating the Line OTX
TLH laser temperature is higher than
the threshold written in the EEPROM
<Condtype>
1.3.6.1.4.1.20044.10.2.3.1.225.14 pm1001lhAlmLineLaserTempHighWarning r
LINE_LASER_TEMP_HIGH_WARNI
NG <Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.2 pm1001lhAlmLineUrg
1.3.6.1.4.1.20044.10.2.3.2.129 pm1001lhAlmdfrmBer

Custom Line Signal Degrade :This


OID indicates that the line input
signal is DEGRADE. The assertion
hysteresis can customized by the
1.3.6.1.4.1.20044.10.2.3.2.129.1 pm1001lhAlmLineSignalDegrade r host <Condtype>
LINE_SIGNAL_DEGRADE
<Probcause> degradedSignal (13)
<Alarmtype> qualityOfServiceAlarm
(3) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


68 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Custom Line Signal Fail :This OID


indicates that the line input signal is
FAIL. The assertion hysteresis can
be customized by the host
1.3.6.1.4.1.20044.10.2.3.2.129.2 pm1001lhAlmLineSignalFail r
<Condtype> LINE_SIGNAL_FAIL
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation (7)
<Polarity> (2)

Fixed Line Signal Degrade :This OID


indicates that the line input signal is
DEGRADE. The assetion hysteresis
is fixed to 10-8 (assertion) and 10-9
1.3.6.1.4.1.20044.10.2.3.2.129.5 pm1001lhAlmLineDegrade r (de-assertion) <Condtype>
LINE_DEGRADE <Probcause>
degradedSignal (13) <Alarmtype>
qualityOfServiceAlarm (3) <Polarity>
(2)

1.3.6.1.4.1.20044.10.2.3.2.208 pm1001lhAlmlineXfpAlarm1

Line Optical Tx Power Low Alarm


:Alarm indicating that the XFP/OTX
transmitter transmitter output power
is lower than the threshold value
written in the XFP/OTX EEPROM
1.3.6.1.4.1.20044.10.2.3.2.208.1 pm1001lhAlmLineTxPowerLowAlarm r
<Condtype>
LINE_TX_POWER_LOW_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Optical Tx Power High Alarm


:Alarm indicating that the XFP/OTX
transmitter transmitter output power
is higher than the threshold value
written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.3.2.208.2 pm1001lhAlmLineTxPowerHighAlarm r
<Condtype>
LINE_TX_POWER_HIGH_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Bias Low Alarm


:Alarm indicating that the XFP/OTX
transmitter laser bias current is lower
than the threshold value written in
1.3.6.1.4.1.20044.10.2.3.2.208.3 pm1001lhAlmLineTxBiasLowAlarm r the XFP/OTX EEPROM <Condtype>
LINE_TX_BIAS_LOW_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Bias High Alarm


:Alarm indicating that the XFP/OTX
transmitter laser bias current is
higher than the threshold value
written in the XFP EEPROM
1.3.6.1.4.1.20044.10.2.3.2.208.4 pm1001lhAlmLineTxBiasHighAlarm r
<Condtype>
LINE_TX_BIAS_HIGH_ALARM
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


69 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Transceiver Temp Low Alarm


:Alarm indicating that the XFP/OTX
temperature is lower than the
threshold value written in the
XFP/OTX EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.3.2.208.7 pm1001lhAlmLineTempLowAlarm r
LINE_TEMP_LOW_ALARM
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Transceiver Temp High Alarm


:Alarm indicating that the XFP/OTX
temperature is higher than the
threshold value written in the XFP
EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.3.2.208.8 pm1001lhAlmLineTempHighAlarm r
LINE_TEMP_HIGH_ALARM
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Optical Rx Power Low Alarm


:Alarm indicating that the XFP
received optical power is lower than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.3.2.208.15 pm1001lhAlmLineRxPowerLowAlarm r XFP EEPROM <Condtype>
LINE_RX_POWER_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Optical Rx Power High Alarm


:Alarm indicating that the XFP
received optical power is higher than
the threshold value written in the
1.3.6.1.4.1.20044.10.2.3.2.208.16 pm1001lhAlmLineRxPowerHighAlarm r XFP EEPROM <Condtype>
LINE_RX_POWER_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.2.212 pm1001lhAlmlineXfpSupplyAlarm

VEE5 Power Supply Low Alarm


:Alarm indicating the XFP/OTX
VEE5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.1 pm1001lhAlmLineVee5LowAlarm r <Condtype>
LINE_VEE5_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VEE5 Power Supply High Alarm


:Alarm indicating the XFP/OTX
VEE5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.2 pm1001lhAlmLineVee5HighAlarm r <Condtype>
LINE_VEE5_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


70 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VCC2 Power Supply Low Alarm


:Alarm indicating the XFP/OTX
VCC2 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.3 pm1001lhAlmLineVcc2LowAlarm r <Condtype>
LINE_VCC2_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply High Alarm


:Alarm indicating the XFP/OTX
VCC2 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.4 pm1001lhAlmLineVcc2HighAlarm r <Condtype>
LINE_VCC2_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply Low Alarm


:Alarm indicating the XFP/OTX
VCC3 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.5 pm1001lhAlmLineVcc3LowAlarm r <Condtype>
LINE_VCC3_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply High Alarm


:Alarm indicating the XFP/OTX
VCC3 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.6 pm1001lhAlmLineVcc3HighAlarm r <Condtype>
LINE_VCC3_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply Low Alarm


:Alarm indicating the XFP/OTX
VCC5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.7 pm1001lhAlmLineVcc5LowAlarm r <Condtype>
LINE_VCC5_LOW_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply High Alarm


:Alarm indicating the XFP/OTX
VCC5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.8 pm1001lhAlmLineVcc5HighAlarm r <Condtype>
LINE_VCC5_HIGH_ALARM
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


71 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VEE5 Power Supply Low Warning


:Warning indicating the XFP/OTX
VEE5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.9 pm1001lhAlmLineVee5LowLineWarning r <Condtype>
LINE_VEE5_LOW_LINE_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VEE5 Power Supply High Warning


:Warning indicating the XFP/OTX
VEE5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.10 pm1001lhAlmLineVee5HighWarning r <Condtype>
LINE_VEE5_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC2 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.11 pm1001lhAlmLineVcc2LowWarning r <Condtype>
LINE_VCC2_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC2 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC2 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.12 pm1001lhAlmLineVcc2HighWarning r <Condtype>
LINE_VCC2_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC3 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.13 pm1001lhAlmLineVcc3LowWarning r <Condtype>
LINE_VCC3_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC3 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC3 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.14 pm1001lhAlmLineVcc3HighWarning r <Condtype>
LINE_VCC3_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


72 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

VCC5 Power Supply Low Warning


:Warning indicating the XFP/OTX
VCC5 power supply is lower than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.15 pm1001lhAlmLineVcc5LowWarning r <Condtype>
LINE_VCC5_LOW_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

VCC5 Power Supply High Warning


:Warning indicating the XFP/OTX
VCC5 power supply is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.212.16 pm1001lhAlmLineVcc5HighWarning r <Condtype>
LINE_VCC5_HIGH_WARNING
<Probcause> powerProblem (36)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.2.224 pm1001lhAlmlineOtxTlhAlarms3

Line modulator aging high alarm


:Alarm indicating the Line OTX TLH
modulator aging is higher than the
threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.224.5 pm1001lhAlmLineModulatorAgingHighAla r <Condtype>
LINE_MODULATOR_AGING_HIGH
_ALA <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Line OTX TLH aging high alarm


:Alarm indicating the Line OTX TLH
aging is higher than the threshold
written in the EEPROM <Condtype>
1.3.6.1.4.1.20044.10.2.3.2.224.6 pm1001lhAlmLineAgingHighAla r
LINE_AGING_HIGH_ALA
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

CDR not Ready :This OID indicates


the Clock Data Recovery unit is not
yet initialized <Help> This alarm
indicates the Clock Data Recovery
1.3.6.1.4.1.20044.10.2.3.2.224.9 pm1001lhAlmLineCdrNotReady r
unit is not yet initialized. <Condtype>
LINE_CDR_NOT_READY
<Probcause> <Alarmtype>
<Polarity> (2)

Line Freq. deviation high alarm


:Alarm indicating the Line OTX TLH
frequency deviation is higher than
the threshold written in the EEPROM
1.3.6.1.4.1.20044.10.2.3.2.224.12 pm1001lhAlmLineFreqDevHighAla r <Condtype>
LINE_FREQ_DEV_HIGH_ALA
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


73 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Laser Temp. High alarm :Alarm


indicating the Line OTX TLH laser
temperature is higher than the
threshold written in the EEPROM
<Condtype>
1.3.6.1.4.1.20044.10.2.3.2.224.14 pm1001lhAlmLineLaserTempHighAla r
LINE_LASER_TEMP_HIGH_ALA
<Probcause>
temperatureUnacceptable (51)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.3 pm1001lhAlmLineCrit
1.3.6.1.4.1.20044.10.2.3.3.7 pm1001lhAlmsynthAlmLine

Line Optical Module present :This


OID indicates that the line optical
interface (XFP or OTX) is not
plugged in. <Help> This alarm
indicates if the line transceiver is
1.3.6.1.4.1.20044.10.2.3.3.7.1 pm1001lhAlmLineXfpAbsent r
present. <Condtype>
LINE_XFP_ABSENT <Probcause>
inputOutputDeviceError (24)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2) <Event> ObjectCDINV

Line Optical Module ready :This OID


indicates that the line optical
interface (XFP or OTX) is not
operational. <Help> This status
indicates if the line transceiver has
1.3.6.1.4.1.20044.10.2.3.3.7.2 pm1001lhAlmLineXfpInitNotCompl r
been correctly initialized <Condtype>
LINE_XFP_INIT_NOT_COMPL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)

Line Port HW Failure :This OID


indicates a failure on line port, most
probably caused by a HW issue
1.3.6.1.4.1.20044.10.2.3.3.7.4 pm1001lhAlmLineHwFail r
<Condtype> LINE_HW_FAIL
<Probcause> <Alarmtype>
<Polarity> (2)

Line optical TX ON :This OID


indicates the line optical output
power is on <Help> This status
indicates if the line transceiver laser
1.3.6.1.4.1.20044.10.2.3.3.7.5 pm1001lhAlmLineXfpTxOff r
is ON or OFF <Condtype>
LINE_XFP_TX_OFF <Probcause>
other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Line port In Service :This OID


indicates that the Line port is In
Service (1) of Out or Service (2)
<Help> This status indicates if the
1.3.6.1.4.1.20044.10.2.3.3.7.6 pm1001lhAlmLineLocalOos r
line port is in service <Condtype>
LINE_LOCAL_OOS <Probcause>
informationalStatus(1000)
<Alarmtype> other (1) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


74 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

MS-RDI/L-RDI inserted on Line :This


OID indicates an upstream RDI has
been inserted in the outgoing 10
Gb/s signal. <Help> This status
indicates if a MS-RDI/L-RDI is
1.3.6.1.4.1.20044.10.2.3.3.7.8 pm1001lhAlmLineUpRdiIns r
currently inserted on the line
interface. <Condtype>
LINE_UP_RDI_INS <Probcause>
informationalStatus(1000)
<Alarmtype> other (1) <Polarity> (2)

Warning on Line Optical Module


DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Help> This alarm
1.3.6.1.4.1.20044.10.2.3.3.7.9 pm1001lhAlmLineDdmWarning r indicates if a DDM Warning has
been detected on the line transceiver
<Condtype> LINE_DDM_WARNING
<Probcause> <Alarmtype>
<Polarity> (2)

Alarm on Line Optical Module DDM


:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Help> This alarm
1.3.6.1.4.1.20044.10.2.3.3.7.10 pm1001lhAlmLineDdmAlm r indicates if a DDM Alarm has been
detected on the line transceiver
<Condtype> LINE_DDM_ALM
<Probcause> <Alarmtype>
<Polarity> (2)

Line Port Failure :This OID indicates


a failure on the line port <Condtype>
1.3.6.1.4.1.20044.10.2.3.3.7.12 pm1001lhAlmLineFail r
LINE_FAIL <Probcause>
<Alarmtype> <Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.3.128 pm1001lhAlmdfrmAlm

MS-AIS/L-AIS detected on line input


:This OID indicates that an MS-AIS
has been detected on line input
signal <Help> This alarm indicates
if there is a MS-AIS/L-AIS is
1.3.6.1.4.1.20044.10.2.3.3.128.1 pm1001lhAlmLineDwAisDet r
detected on the line input signal
<Condtype> LINE_DW_AIS_DET
<Probcause> receiveFailure (41)
<Alarmtype> operationalViolation (8)
<Polarity> (2)

MS-RDI/L-RDI detected on line input


:This OID indicates that an MS-RDI
has been detected on line input
signal <Help> This alarm indicates
if there is a MS-RDI/L-RDI is
1.3.6.1.4.1.20044.10.2.3.3.128.2 pm1001lhAlmLineDwRdiDet r
detected on the line input signal
<Condtype> LINE_DW_RDI_DET
<Probcause>
remoteNodeTransmissionError (43)
<Alarmtype> other (1) <Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


75 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

SONET/SDH Line Loss Of Frame


:This OID indicates that a Loss Of
Frame has been detected on line
input signal <Help> This alarm
indicates if there is a Loss of Frame
1.3.6.1.4.1.20044.10.2.3.3.128.4 pm1001lhAlmLineDwLof r
is detected on the line input signal
<Condtype> LINE_DW_LOF
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation (7)
<Polarity> (2)

FEC Decoding Fail :This OID


indicates that the FEC decoder is in
an overcapacity mode and not able
to correct errors <Help> This alarm
1.3.6.1.4.1.20044.10.2.3.3.128.5 pm1001lhAlmLineFecFail r
indicates if the FEC decoder is in an
over capacity mode <Condtype>
LINE_FEC_FAIL <Probcause>
<Alarmtype>

1.3.6.1.4.1.20044.10.2.3.3.133 pm1001lhAlmlineSyncAlarms

Downstream Clock Lock Error :This


OID indicates that the deserializer
input 10 Gb/s clock recovery is not
1.3.6.1.4.1.20044.10.2.3.3.133.12 pm1001lhAlmLineDwLockerr r
locked. <Condtype>
LINE_DW_LOCKERR <Probcause>
<Alarmtype> <Polarity> (2)

Upstream Clock Lock Error :This


OID indicates that the serializer
output 10 Gb/s clock multiplier unit is
1.3.6.1.4.1.20044.10.2.3.3.133.13 pm1001lhAlmLineUpLockerr r
not locked. <Condtype>
LINE_UP_LOCKERR <Probcause>
<Alarmtype> <Polarity> (2)

Line input Loss of Signal :This OID


indicates a loss of signal on the 10
Gb/s input. <Help> This alarm
indicates if an optical signal is
1.3.6.1.4.1.20044.10.2.3.3.133.16 pm1001lhAlmLineDwLos r detected on the line transceiver input
<Condtype> LINE_DW_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)

1.3.6.1.4.1.20044.10.2.3.3.211 pm1001lhAlmlineXfpAlarms2

Line Optical Module not ready :This


OID indicates that the module is
unable to determine correct data.
1.3.6.1.4.1.20044.10.2.3.3.211.2 pm1001lhAlmLineModNr r <Help> This alarm indicates if the
line transceiver is ready <Condtype>
LINE_MOD_NR <Probcause>
<Alarmtype> <Polarity> (2)

Line Optical Rx CDR unlocked :This


OID indicates that a loss of lock on
the receiving side CDR has been
detected <Help> This alarm
indicates if the Rx CDR is locked in
1.3.6.1.4.1.20044.10.2.3.3.211.3 pm1001lhAlmLineRxCdrNotLocked1 r
the line transceiver <Condtype>
LINE_RX_CDR_NOT_LOCKED1
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


76 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Optical Rx not ready :This OID


indicates that a condition has arisen
leading to invalid data on the
receiving side. <Help> This alarm
1.3.6.1.4.1.20044.10.2.3.3.211.5 pm1001lhAlmLineRxNr r
indicates if the Rx part of the line
transceiver is ready <Condtype>
LINE_RX_NR <Probcause>
<Alarmtype> <Polarity> (2)

Line Optical Tx CDR unlocked :This


OID indicates a loss of lock on the
transmitting side CDR has been
detected. <Help> This alarm
indicates if the Tx CDR is locked in
1.3.6.1.4.1.20044.10.2.3.3.211.6 pm1001lhAlmLineTxCdrNotLocked1 r
the line transceiver <Condtype>
LINE_TX_CDR_NOT_LOCKED1
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Optical Tx Failure :This OID


indicates a fault condition on the
laser detected by the safety syste
<Help> This alarm indicates if the
1.3.6.1.4.1.20044.10.2.3.3.211.7 pm1001lhAlmLineTxFault r laser of the line transceiver is in fail
condition <Condtype>
LINE_TX_FAULT <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)

Line Optical Tx not ready :This OID


indicates a condition has arisen
leading to invalid data on the
transmitting side <Help> This alarm
1.3.6.1.4.1.20044.10.2.3.3.211.8 pm1001lhAlmLineTxNr r
indicates if the Tx part of the line
transceiver is ready <Condtype>
LINE_TX_NR <Probcause>
<Alarmtype> <Polarity> (2)

DWDM Channel Not Acquired :This


OID indicates the transceiver didn't
tune the DWDM Channel
succesfully. <Help> This status
indicates the transceiver has not
1.3.6.1.4.1.20044.10.2.3.3.211.10 pm1001lhAlmLineChannelNotAcquired r
tuned the DWDM Channel
succesfully. <Condtype>
LINE_CHANNEL_NOT_ACQUIRED
<Probcause> <Alarmtype>
<Polarity> (2)

Line Optical Tx Wavelength unlock


:This OID indicates that the
wavelength error is exceeding the
manufacturer tolerance <Help>
This alarm indicates if the
1.3.6.1.4.1.20044.10.2.3.3.211.14 pm1001lhAlmLineWavelengthUnlocked r wavelenght of the line transceiver is
locked <Condtype>
LINE_WAVELENGTH_UNLOCKED
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Ekinops PM C1001HC(-ETR) documentation


77 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line Optical Tx Temp Regul. Failed


:This OID indicates a failure on the
TEC module <Help> This alarm
indicates if the TEC of the line
1.3.6.1.4.1.20044.10.2.3.3.211.15 pm1001lhAlmLineTecFault r transceiver is in fail condition
<Condtype> LINE_TEC_FAULT
<Probcause> transmitterFailure (56)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

Line Rx Photodiode Power Failed


:This OID indicates a failure on the
APD power supply <Help> This
alarm indicates if the APD power
supply is in fail condition
1.3.6.1.4.1.20044.10.2.3.3.211.16 pm1001lhAlmLineApdSupplyFault r
<Condtype>
LINE_APD_SUPPLY_FAULT
<Probcause> receiverFailure (42)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)

1.3.6.1.4.1.20044.10.3 pm1001lhmeasures
1.3.6.1.4.1.20044.10.3.1 pm1001lhMesrOther
1.3.6.1.4.1.20044.10.3.2 pm1001lhMesrClient

Client XFP Temperature :This OID


gives the temperature value of the
XFP plugged in port, read from the
1.3.6.1.4.1.20044.10.3.2.16 pm1001lhMesrclientModTempMeas r DDM (Digital Diagnostic Monitoring)
(Unit = C) <Help> This measure
gives the temperature of the client
transceiver

Client XFP Laser Bias :This OID


gives the bias value of the XFP
plugged into port, read from the
1.3.6.1.4.1.20044.10.3.2.32 pm1001lhMesrclientBiasCurrentMeas r DDM (Digital Diagnostic Monitoring)
(Unit = mA) <Help> This measure
gives the bias of the client
transceiver

Client XFP Transmitted Power :This


OID gives the transmit power value
of the XFP plugged into port, read
1.3.6.1.4.1.20044.10.3.2.40 pm1001lhMesrclientTxPowerMeas r from the DDM (Digital Diagnostic
Monitoring) (Unit = dBm) <Help>
This measure gives the Tx optical
power of the client transceiver

Client XFP Received Power :This


OID gives the receive power value of
the XFP plugged into port, read in
1.3.6.1.4.1.20044.10.3.2.48 pm1001lhMesrclientRxPowerMeas r the DDM (Digital Diagnostic
Monitoring) (Unit = dBm) <Help>
This measure gives the Rx optical
power of the client transceiver

1.3.6.1.4.1.20044.10.3.3 pm1001lhMesrLine

XFP or OTX Temperature :This OID


gives the temperature of the XFP or
OTX plugged in line#1, read from the
1.3.6.1.4.1.20044.10.3.3.208 pm1001lhMesrlineModTempMeas r DDM (Digital Diagnostic Monitoring)
(Unit = C) <Help> This measure
gives the temperature of the line
transceiver

Ekinops PM C1001HC(-ETR) documentation


78 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

XFP or OTX transmitter bias current


:This OID gives the bias value of the
XFP or OTX plugged in line #1, read
1.3.6.1.4.1.20044.10.3.3.210 pm1001lhMesrlineBiasCurrentMeas r from the DDM (Digital Diagnostic
Monitoring) (Unit = mA) <Help>
This measure gives the bias of the
line transceiver

XFP or OTX Transmitted power


:This OID gives the transmit power
value of the XFP or OTX plugged in
1.3.6.1.4.1.20044.10.3.3.211 pm1001lhMesrlineTxPowerMeas r line #1, read from the DDM (Digital
Diagnostic Monitoring) (Unit = dBm)
<Help> This measure gives the Tx
optical power of the line transceiver

XFP or OTX Received power :This


OID gives the receive power value of
the XFP or OTX plugged in line #1,
1.3.6.1.4.1.20044.10.3.3.212 pm1001lhMesrlineRxPowerMeas r read from the DDM (Digital
Diagnostic Monitoring) (Unit = dBm)
<Help> This measure gives the Rx
optical power of the line transceiver

Line OTX TLH aging :This OID gives


the aging of the Line OTX TLH, read
from the DDM (Digital Diagnostic
1.3.6.1.4.1.20044.10.3.3.224 pm1001lhMesrlineAging r
Monitoring) (Unit = %) <Help> This
measure gives the aging of the Line
OTX TLH

Line OTX TLH Frequency deviation


:This OID gives the frequency
deviation of the Line OTX TLH, read
1.3.6.1.4.1.20044.10.3.3.226 pm1001lhMesrlineFreqDeviation r from the DDM (Digital Diagnostic
Monitoring) (Unit = MHz) <Help>
This measure gives the frequency
deviation of the Line OTX TLH

Line OTX TLH Laser wavelength


:This OID gives the laser wavelength
of the Line OTX TLH, read from the
1.3.6.1.4.1.20044.10.3.3.227 pm1001lhMesrlineLaserWvlength r DDM (Digital Diagnostic Monitoring)
(Unit = nm) <Help> This measure
gives the laser wavelength of the
Line OTX TLH

1.3.6.1.4.1.20044.10.4 pm1001lhcounters
1.3.6.1.4.1.20044.10.4.1 pm1001lhCntOther
1.3.6.1.4.1.20044.10.4.2 pm1001lhCntClient
List of pm1001lhCntclientUpErrCnt
1.3.6.1.4.1.20044.10.4.2.32 pm1001lhCntclientUpErrCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.2.32.1 pm1001lhCntclientUpErrCntEntry n/a
pm1001lhCntclientUpErrCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.2.32.1.1 pm1001lhCntclientUpErrCntIndex r
pm1001lhCntclientUpErrCnt table

Client input counter :This counter is


increased each time a FCS error is
detected in 10GbE mode or a B1
error is detected in OC-192/STM-64
1.3.6.1.4.1.20044.10.4.2.32.1.2 pm1001lhCntclientUpErrCntValuePortn r
mode on the client input stream
<Help> This counter gives the
number of FCS errors or B1 errors
on the client input port

Ekinops PM C1001HC(-ETR) documentation


79 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client counter error :This OID when


1.3.6.1.4.1.20044.10.4.2.32.1.3 pm1001lhCntclientUpErrCntErrorPortn r set indicates the FCS error counter
value is invalid on input Port
Client counter overload :This OID
1.3.6.1.4.1.20044.10.4.2.32.1.4 pm1001lhCntclientUpErrCntOverloadPortn r when set indicates a FCS error
counter overload on input Port
List of pm1001lhCntclientUpTimCnt
1.3.6.1.4.1.20044.10.4.2.40 pm1001lhCntclientUpTimCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.2.40.1 pm1001lhCntclientUpTimCntEntry n/a
pm1001lhCntclientUpTimCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.2.40.1.1 pm1001lhCntclientUpTimCntIndex r
pm1001lhCntclientUpTimCnt table
Client upstream timer counter :This
is the timing counter dedicated to the
1.3.6.1.4.1.20044.10.4.2.40.1.2 pm1001lhCntclientUpTimCntValuePortn r
upstream access counters. It is
incremented every 125 us.

Client counter error :This OID when


1.3.6.1.4.1.20044.10.4.2.40.1.3 pm1001lhCntclientUpTimCntErrorPortn r set indicates the upstream timing
counter value is invalid on Port
Client counter overload :This OID
1.3.6.1.4.1.20044.10.4.2.40.1.4 pm1001lhCntclientUpTimCntOverloadPortn r when set indicates a upstream
timing counter overload on Port
List of pm1001lhCntclientDwErrCnt
1.3.6.1.4.1.20044.10.4.2.64 pm1001lhCntclientDwErrCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.2.64.1 pm1001lhCntclientDwErrCntEntry n/a
pm1001lhCntclientDwErrCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.2.64.1.1 pm1001lhCntclientDwErrCntIndex r
pm1001lhCntclientDwErrCnt table

Client output counter :This counter is


increased each time a B1/FCS error
is detected on the client output
1.3.6.1.4.1.20044.10.4.2.64.1.2 pm1001lhCntclientDwErrCntValuePortn r
stream <Help> This counter gives
the number of FCS errors or B1
errors on the client output port

Client counter error :This OID when


1.3.6.1.4.1.20044.10.4.2.64.1.3 pm1001lhCntclientDwErrCntErrorPortn r set indicates the FCS error counter
value is invalid on output Port
Client counter overload :This OID
1.3.6.1.4.1.20044.10.4.2.64.1.4 pm1001lhCntclientDwErrCntOverloadPortn r when set indicates a FCS error
counter overload on output Port
List of pm1001lhCntclientDwTimCnt
1.3.6.1.4.1.20044.10.4.2.72 pm1001lhCntclientDwTimCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.2.72.1 pm1001lhCntclientDwTimCntEntry n/a
pm1001lhCntclientDwTimCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.2.72.1.1 pm1001lhCntclientDwTimCntIndex r
pm1001lhCntclientDwTimCnt table

Client downstream timer counter


:This is the timing counter dedicated
1.3.6.1.4.1.20044.10.4.2.72.1.2 pm1001lhCntclientDwTimCntValuePortn r
to the downstream access counters.
It is incremented every 125 us.

Client counter error :This OID when


1.3.6.1.4.1.20044.10.4.2.72.1.3 pm1001lhCntclientDwTimCntErrorPortn r set indicates the downstream timer
counter value is invalid on Port
Client counter overload :This OID
1.3.6.1.4.1.20044.10.4.2.72.1.4 pm1001lhCntclientDwTimCntOverloadPortn r when set indicates a downstream
timer counter overload on Port
1.3.6.1.4.1.20044.10.4.3 pm1001lhCntLine
List of pm1001lhCntlineDfrmErrCnt
1.3.6.1.4.1.20044.10.4.3.152 pm1001lhCntlineDfrmErrCntTable n/a
Article
Ekinops PM C1001HC(-ETR) documentation
80 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Row definition for the


1.3.6.1.4.1.20044.10.4.3.152.1 pm1001lhCntlineDfrmErrCntEntry n/a
pm1001lhCntlineDfrmErrCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.3.152.1.1 pm1001lhCntlineDfrmErrCntIndex r
pm1001lhCntlineDfrmErrCnt table

Line B1 error counter :This counter


is incremented each time a B1 error
is detected on the Deframer input
1.3.6.1.4.1.20044.10.4.3.152.1.2 pm1001lhCntlineDfrmErrCntValuePortn r
stream. <Help> This counter gives
the number of B1 errors on the line
port

Line counter error :This OID when


1.3.6.1.4.1.20044.10.4.3.152.1.3 pm1001lhCntlineDfrmErrCntErrorPortn r set indicates the B1 error counter
value is invalid on Port
Line counter overload :This OID
1.3.6.1.4.1.20044.10.4.3.152.1.4 pm1001lhCntlineDfrmErrCntOverloadPortn r when set indicates a B1 error
counter overload on Port
List of pm1001lhCntlineDfrmTimCnt
1.3.6.1.4.1.20044.10.4.3.153 pm1001lhCntlineDfrmTimCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.3.153.1 pm1001lhCntlineDfrmTimCntEntry n/a
pm1001lhCntlineDfrmTimCnt table
Index definition for the
1.3.6.1.4.1.20044.10.4.3.153.1.1 pm1001lhCntlineDfrmTimCntIndex r
pm1001lhCntlineDfrmTimCnt table
Line timer counter :This is the timing
counter dedicated to the
1.3.6.1.4.1.20044.10.4.3.153.1.2 pm1001lhCntlineDfrmTimCntValuePortn r
downstream deframer counters. It is
incremented every 125 us.

Line counter error :This OID when


1.3.6.1.4.1.20044.10.4.3.153.1.3 pm1001lhCntlineDfrmTimCntErrorPortn r set indicates the deframer timer
counter value is invalid on Port
Line counter overload :This OID
1.3.6.1.4.1.20044.10.4.3.153.1.4 pm1001lhCntlineDfrmTimCntOverloadPortn r when set indicates a deframer timer
counter overload on Port
List of
1.3.6.1.4.1.20044.10.4.3.154 pm1001lhCntlineDfrmPrimErrCntTable n/a pm1001lhCntlineDfrmPrimErrCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.3.154.1 pm1001lhCntlineDfrmPrimErrCntEntry n/a pm1001lhCntlineDfrmPrimErrCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.4.3.154.1.1 pm1001lhCntlineDfrmPrimErrCntIndex r pm1001lhCntlineDfrmPrimErrCnt
table

FEC Corrected Errors counter :This


counter is incremented each time an
error is corrected by the Forward
1.3.6.1.4.1.20044.10.4.3.154.1.2 pm1001lhCntlineDfrmPrimErrCntValuePortn r Error Correction decoder <Help>
This counter gives the number of
errors corrected by the FEC on the
line port

Line FEC counter error :This bit


1.3.6.1.4.1.20044.10.4.3.154.1.3 pm1001lhCntlineDfrmPrimErrCntErrorPortn r when set indicates the FEC counter
value is invalid on Port
Line FEC counter overload :This bit
1.3.6.1.4.1.20044.10.4.3.154.1.4 pm1001lhCntlineDfrmPrimErrCntOverloadPortn r when set indicates a FEC counter
overload on Port
List of pm1001lhCntlineDfrmErrCntS
1.3.6.1.4.1.20044.10.4.3.1160 pm1001lhCntlineDfrmErrCntSTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.4.3.1160.1 pm1001lhCntlineDfrmErrCntSEntry n/a
pm1001lhCntlineDfrmErrCntS table
Index definition for the
1.3.6.1.4.1.20044.10.4.3.1160.1.1 pm1001lhCntlineDfrmErrCntSIndex r
pm1001lhCntlineDfrmErrCntS table

Ekinops PM C1001HC(-ETR) documentation


81 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line B1 error rate (/s) :This OID


gives the number of B1 errors per
1.3.6.1.4.1.20044.10.4.3.1160.1.2 pm1001lhCntlineDfrmErrCntSValuePortn r
second that are detected on the
Deframer input stream.

1.3.6.1.4.1.20044.10.4.3.1160.1.3 pm1001lhCntlineDfrmErrCntSErrorPortn r
1.3.6.1.4.1.20044.10.4.3.1160.1.4 pm1001lhCntlineDfrmErrCntSOverloadPortn r
Counters Reset:This OID resets and
1.3.6.1.4.1.20044.10.4.259 pm1001lhCntCountersReset r/w
restarts all the counters
Counters stop:This OID stops all the
1.3.6.1.4.1.20044.10.4.260 pm1001lhCntCountersStop r/w
counters
1.3.6.1.4.1.20044.10.6 pm1001lhcontrolsWrite
1.3.6.1.4.1.20044.10.6.1 pm1001lhCtrlOther
1.3.6.1.4.1.20044.10.6.1.1 pm1001lhCtrlconfMgnt1

Load Configuration Tables set nb 1


:When set this OID enables loading
1.3.6.1.4.1.20044.10.6.1.1.1 pm1001lhCtrlConf1Load1 r/w
from flash configuration1 into the
PM.

Load Configuration Tables set nb 2


:When set this OID enables loading
1.3.6.1.4.1.20044.10.6.1.1.2 pm1001lhCtrlConf2Load1 r/w
from flash configuration2 into the
PM.

Write Configuration Tables :This OID


saves the current configuration of
the PM as configuration2 in the
1.3.6.1.4.1.20044.10.6.1.1.10 pm1001lhCtrlConf2Flash1 r/w
flash. <Help> This control saves
the customer configuration on the
module

Clear Configuration Tables :This OID


clears the configuration tables from
1.3.6.1.4.1.20044.10.6.1.1.14 pm1001lhCtrlConf2Clear1 r/w configuration2 in the flash. <Help>
This control restores the default
configuration of the module

1.3.6.1.4.1.20044.10.6.1.4 pm1001lhCtrlsynth4
Enable Alarm Correlation :This OID
1.3.6.1.4.1.20044.10.6.1.4.1 pm1001lhCtrlCorrelatOn r/w enables the alarm correlation in the
PM.
Disable Alarm Correlation :This OID
1.3.6.1.4.1.20044.10.6.1.4.2 pm1001lhCtrlCorrelatOff r/w disables the alarm correlation in the
PM.
1.3.6.1.4.1.20044.10.6.1.5 pm1001lhCtrlswMgnt

PM Cold Reset :This OID, when set,


causes a cold reset of the PM. This
reset is traffic affecting, and the
1.3.6.1.4.1.20044.10.6.1.5.2 pm1001lhCtrlColdReset r/w
configuration of PM is reloaded on
start-up. <Help> This control
initiates a cold reset of the module.

PM Warm Reset :This OID, when


set, causes a warm reset of the PM.
This reset is not traffic affecting, and
1.3.6.1.4.1.20044.10.6.1.5.3 pm1001lhCtrlWarmReset r/w
the configuration of PM remains
unchanged. <Help> This control
initiates a warm reset of the module.

Ekinops PM C1001HC(-ETR) documentation


82 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Set Software nb 1 as active :This


OID, when set, loads the SW from
bank1 into the PM. It must be
1.3.6.1.4.1.20044.10.6.1.5.5 pm1001lhCtrlLoadSwBank1 r/w followed by a reset. <Help> This
controls selects the first SW bank as
the active bank for the next module
reset

Set Software nb 2 as active :This


OID, when set, loads the SW from
bank2 into the PM. It must be
1.3.6.1.4.1.20044.10.6.1.5.6 pm1001lhCtrlLoadSwBank2 r/w followed by a reset. <Help> This
controls selects the second SW bank
as the active bank for the next
module reset

1.3.6.1.4.1.20044.10.6.1.6 pm1001lhCtrlgwMgnt
Active Gateware Reset :This OID,
1.3.6.1.4.1.20044.10.6.1.6.1 pm1001lhCtrlCurrentGwReset r/w when set, resets the active
gateware. It is traffic affecting.

Set Gateware nb 1 as active :This


OID, when set, loads the GW from
bank1 (Flash) into the PM. It is
followed by an automatic gateware
1.3.6.1.4.1.20044.10.6.1.6.5 pm1001lhCtrlLoadGwBank1 r/w
cold reset. <Help> This controls
initiates a cold reset of the module
and select the first GW bank as the
active bank

Set Gateware nb 2 as active :This


OID, when set, loads the GW from
1.3.6.1.4.1.20044.10.6.1.6.6 pm1001lhCtrlLoadGwBank2 r/w bank2 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.

Set Gateware nb 3 as active :This


OID, when set, loads the GW from
bank3 (Flash) into the PM. It is
followed by an automatic gateware
1.3.6.1.4.1.20044.10.6.1.6.7 pm1001lhCtrlLoadGwBank3 r/w
cold reset. <Help> This controls
initiates a cold reset of the module
and select the third GW bank as the
active bank

Set Gateware nb 4 as active :This


OID, when set, loads the GW from
1.3.6.1.4.1.20044.10.6.1.6.8 pm1001lhCtrlLoadGwBank4 r/w bank4 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.

1.3.6.1.4.1.20044.10.6.1.192 pm1001lhCtrlledTest

Green Leds Test :This OID switches


on all the green Leds as a test
1.3.6.1.4.1.20044.10.6.1.192.1 pm1001lhCtrlGreenLed r/w feature. <Help> This control
initiates a test leds turning all the
LEDs to green

Red Leds Test :This OID switches


on all the red Leds as a test feature.
1.3.6.1.4.1.20044.10.6.1.192.2 pm1001lhCtrlRedLed r/w
<Help> This control initiates a test
leds turning all the LEDs to red

Leds Off :This OID switches off all


the Leds as a test feature. <Help>
1.3.6.1.4.1.20044.10.6.1.192.3 pm1001lhCtrlLedOff r/w
This control initiates a test leds
turning all the LEDs to OFF

1.3.6.1.4.1.20044.10.6.1.193 pm1001lhCtrlmoduleOosMode

Ekinops PM C1001HC(-ETR) documentation


83 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

PM Out Of Service :This OID sets


the PM1008 Out Of Service <Help>
1.3.6.1.4.1.20044.10.6.1.193.1 pm1001lhCtrlModuleOosMode r/w
This control defines the service state
of the complete module

1.3.6.1.4.1.20044.10.6.1.197 pm1001lhCtrlmaintenanceMode

Enable Maintenance :This OID


enables the maintenance mode on
1.3.6.1.4.1.20044.10.6.1.197.1 pm1001lhCtrlMaintenanceMode r/w the PM. <Help> This control
enables the maintenance mode on
the PM.

1.3.6.1.4.1.20044.10.6.1.198 pm1001lhCtrldccEnable

DCC Mode :This OID enables the


DCC mode on the PM <Help>
1.3.6.1.4.1.20044.10.6.1.198.1 pm1001lhCtrlDccEnable r/w
This control enables the DCC mode
on the PM

1.3.6.1.4.1.20044.10.6.2 pm1001lhCtrlClient
List of pm1001lhCtrlaccessLoop
1.3.6.1.4.1.20044.10.6.2.16 pm1001lhCtrlaccessLoopTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.2.16.1 pm1001lhCtrlaccessLoopEntry n/a
pm1001lhCtrlaccessLoop table
Index definition for the
1.3.6.1.4.1.20044.10.6.2.16.1.1 pm1001lhCtrlaccessLoopIndex r
pm1001lhCtrlaccessLoop table
Client Access Loop Back :This OID
1.3.6.1.4.1.20044.10.6.2.16.1.2 pm1001lhCtrlaccessLoopPortn r/w operates an access loopback on the
Client port.
List of pm1001lhCtrlportOosMode
1.3.6.1.4.1.20044.10.6.2.18 pm1001lhCtrlportOosModeTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.2.18.1 pm1001lhCtrlportOosModeEntry n/a
pm1001lhCtrlportOosMode table
Index definition for the
1.3.6.1.4.1.20044.10.6.2.18.1.1 pm1001lhCtrlportOosModeIndex r
pm1001lhCtrlportOosMode table
Client port Out of Service :This OID
sets the client port Out Of Service
1.3.6.1.4.1.20044.10.6.2.18.1.2 pm1001lhCtrlportOosModePortn r/w
<Help> This controls defines the
service state of the client port

1.3.6.1.4.1.20044.10.6.2.20 pm1001lhCtrlxfpOffCtrlTable n/a List of pm1001lhCtrlxfpOffCtrl Article

Row definition for the


1.3.6.1.4.1.20044.10.6.2.20.1 pm1001lhCtrlxfpOffCtrlEntry n/a
pm1001lhCtrlxfpOffCtrl table
Index definition for the
1.3.6.1.4.1.20044.10.6.2.20.1.1 pm1001lhCtrlxfpOffCtrlIndex r
pm1001lhCtrlxfpOffCtrl table
Client XFP Optical Laser OFF :This
OID switches off the XFP. <Help>
1.3.6.1.4.1.20044.10.6.2.20.1.2 pm1001lhCtrlxfpOffCtrlPortn r/w
This control defines the laser state of
the client transceiver

1.3.6.1.4.1.20044.10.6.2.21 pm1001lhCtrlcsfUpInsTable n/a List of pm1001lhCtrlcsfUpIns Article


Row definition for the
1.3.6.1.4.1.20044.10.6.2.21.1 pm1001lhCtrlcsfUpInsEntry n/a
pm1001lhCtrlcsfUpIns table
Index definition for the
1.3.6.1.4.1.20044.10.6.2.21.1.1 pm1001lhCtrlcsfUpInsIndex r
pm1001lhCtrlcsfUpIns table

Client Signal Fail Insertion :This OID,


when set, inserts a client signal fail
1.3.6.1.4.1.20044.10.6.2.21.1.2 pm1001lhCtrlcsfUpInsPortn r/w in the upstream client Port. <Help>
This control inserts a Client Signal
Fail for the client port

List of pm1001lhCtrlcaisDwIns
1.3.6.1.4.1.20044.10.6.2.22 pm1001lhCtrlcaisDwInsTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.2.22.1 pm1001lhCtrlcaisDwInsEntry n/a
pm1001lhCtrlcaisDwIns table
Ekinops PM C1001HC(-ETR) documentation
84 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Index definition for the


1.3.6.1.4.1.20044.10.6.2.22.1.1 pm1001lhCtrlcaisDwInsIndex r
pm1001lhCtrlcaisDwIns table

Client AIS Insertion :This OID, when


set, inserts a client AIS on the
1.3.6.1.4.1.20044.10.6.2.22.1.2 pm1001lhCtrlcaisDwInsPortn r/w downstream client Port. <Help>
This control inserts a Client AIS for
the client port

Protocol used for client port :This


1.3.6.1.4.1.20044.10.6.2.52 pm1001lhCtrlprotocol r/w OID sets the protocol of the Client
port
List of
1.3.6.1.4.1.20044.10.6.2.271 pm1001lhCtrlclientResetAllCountTable n/a pm1001lhCtrlclientResetAllCount
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.2.271.1 pm1001lhCtrlclientResetAllCountEntry n/a pm1001lhCtrlclientResetAllCount
table
Index definition for the
1.3.6.1.4.1.20044.10.6.2.271.1.1 pm1001lhCtrlclientResetAllCountIndex r pm1001lhCtrlclientResetAllCount
table

Client Counters Reset :This OID


resets every counter on the client
port <Help> This control operates
1.3.6.1.4.1.20044.10.6.2.271.1.2 pm1001lhCtrlclientResetAllCountsPortn r/w
a reset on the statistics current
,previous and history client port
counters

1.3.6.1.4.1.20044.10.6.3 pm1001lhCtrlLine
1.3.6.1.4.1.20044.10.6.3.64 pm1001lhCtrlcommAccessLoop
1.3.6.1.4.1.20044.10.6.3.66 pm1001lhCtrllineLoop
1.3.6.1.4.1.20044.10.6.3.67 pm1001lhCtrlmsAis

Insert MS-AIS/L-AIS on Line output


:This OID, when set, inserts an MS-
1.3.6.1.4.1.20044.10.6.3.67.1 pm1001lhCtrlMsAis r/w
AIS/L-AIS in the outgoing STM-
64/OC-192 signal.

1.3.6.1.4.1.20044.10.6.3.69 pm1001lhCtrlfecDisable

FEC Disable :This OID disable the


Forward Error Correction decoder on
1.3.6.1.4.1.20044.10.6.3.69.1 pm1001lhCtrlFecInhibition r/w the line receive side <Help> This
control disables the Forward Error
Correction on the line input signal.

S1 value inserted on line output :The


value to be written in the upstream
1.3.6.1.4.1.20044.10.6.3.70 pm1001lhCtrlupS1 r/w S1 byte of the OC-192c/STM-64c
signal is accessible through the
present element.

K1 value inserted on line output :The


value to be written in the upstream
1.3.6.1.4.1.20044.10.6.3.71 pm1001lhCtrlupK1 r/w K1 byte of the OC-192c/STM-64c
signal is accessible through the
present element.

K2 value inserted on line output :The


value to be written in the upstream
1.3.6.1.4.1.20044.10.6.3.72 pm1001lhCtrlupK2 r/w K2 byte of the OC-192c/STM-64c
signal is accessible through the
present element.

1.3.6.1.4.1.20044.10.6.3.74 pm1001lhCtrllineOosMode

Ekinops PM C1001HC(-ETR) documentation


85 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Line port Out of Service :This OID


sets the line port Out Of Service
1.3.6.1.4.1.20044.10.6.3.74.1 pm1001lhCtrlLineOosMode r/w
<Help> This control defines the
service state of the line port

1.3.6.1.4.1.20044.10.6.3.208 pm1001lhCtrlxfpOnoffTable n/a List of pm1001lhCtrlxfpOnoff Article


Row definition for the
1.3.6.1.4.1.20044.10.6.3.208.1 pm1001lhCtrlxfpOnoffEntry n/a
pm1001lhCtrlxfpOnoff table
Index definition for the
1.3.6.1.4.1.20044.10.6.3.208.1.1 pm1001lhCtrlxfpOnoffIndex r
pm1001lhCtrlxfpOnoff table

XFP/OTX Optical Laser OFF :This


OID switches off the XFP or the OTX
1.3.6.1.4.1.20044.10.6.3.208.1.2 pm1001lhCtrlxfpOnoffPortn r/w
<Help> This control defines the
laser state of the line transceiver

List of pm1001lhCtrlxfpLineLoop
1.3.6.1.4.1.20044.10.6.3.209 pm1001lhCtrlxfpLineLoopTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.3.209.1 pm1001lhCtrlxfpLineLoopEntry n/a
pm1001lhCtrlxfpLineLoop table
Index definition for the
1.3.6.1.4.1.20044.10.6.3.209.1.1 pm1001lhCtrlxfpLineLoopIndex r
pm1001lhCtrlxfpLineLoop table

Line XFP/OTX Loop :This OID


operates a line loopback on the line
1.3.6.1.4.1.20044.10.6.3.209.1.2 pm1001lhCtrlxfpLineLoopPortn r/w XFP or the OTX <Help> This
control defines the line loop back of
the line transceiver

List of pm1001lhCtrlxfpLineXfiLoop
1.3.6.1.4.1.20044.10.6.3.210 pm1001lhCtrlxfpLineXfiLoopTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.3.210.1 pm1001lhCtrlxfpLineXfiLoopEntry n/a
pm1001lhCtrlxfpLineXfiLoop table
Index definition for the
1.3.6.1.4.1.20044.10.6.3.210.1.1 pm1001lhCtrlxfpLineXfiLoopIndex r
pm1001lhCtrlxfpLineXfiLoop table

Line XFP/OTX XFI Loop :This OID


operates a XFI loopback on the line
1.3.6.1.4.1.20044.10.6.3.210.1.2 pm1001lhCtrlxfpLineXfiLoopPortn r/w XFP or the OTX <Help> This
control defines the XFI loop back of
the line transceiver

ITU Channel :This OID selects the


ITU channel of the Line OTX TLH
1.3.6.1.4.1.20044.10.6.3.212 pm1001lhCtrllineTunableChannel r/w Laser <Help> This control defines
the ITU channel of the Line OTX
TLH Laser

OTX TLH Rx sens. mode :This OID


defines the Rx sensiblity mode of the
Line OTX TLH <Help> This control
1.3.6.1.4.1.20044.10.6.3.213 pm1001lhCtrllinePhotodiodeMode r/w
defines the receiver sensibility mode
of the Line OTX TLH Laser (OTX60,
OTX80 or Custom)

OTX TLH Rx sensibility :This OID


sets the Rx sensibility of the Line
OTX TLH (custom mode only)
1.3.6.1.4.1.20044.10.6.3.214 pm1001lhCtrllinePhotodiodeValue r/w <Help> This control defines the
receiver sensibility value (only in
Custom mode) of the Line OTX TLH
Laser

Ekinops PM C1001HC(-ETR) documentation


86 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Laser Output power [3-5] :This OID


sets the output power value on the
laser of the Line OTX TLH (Unit =
1.3.6.1.4.1.20044.10.6.3.215 pm1001lhCtrllinePowerLaser r/w
dBm) <Help> This control defines
the start-up output power of the Line
OTX TLH

1.3.6.1.4.1.20044.10.6.3.216 pm1001lhCtrlotxVlhReset

OTX-VLH Reset :This OID resets


the OTX-VLH module <Help> This
1.3.6.1.4.1.20044.10.6.3.216.1 pm1001lhCtrlOtxVlhReset r/w
control resets the OTX-VLH and its
parameters

List of
1.3.6.1.4.1.20044.10.6.3.335 pm1001lhCtrllineResetAllCountTable n/a pm1001lhCtrllineResetAllCount
Article
Row definition for the
1.3.6.1.4.1.20044.10.6.3.335.1 pm1001lhCtrllineResetAllCountEntry n/a
pm1001lhCtrllineResetAllCount table
Index definition for the
1.3.6.1.4.1.20044.10.6.3.335.1.1 pm1001lhCtrllineResetAllCountIndex r
pm1001lhCtrllineResetAllCount table

Line Counters Reset :This OID


resets every counter on the line port
<Help> This control operates a
1.3.6.1.4.1.20044.10.6.3.335.1.2 pm1001lhCtrllineResetAllCountsPortn r/w
reset on the statistics current
,previous and history line port
counters

1.3.6.1.4.1.20044.10.7 pm1001lhri
1.3.6.1.4.1.20044.10.7.1 pm1001lhriTable
Reload the inventory: This OID
1.3.6.1.4.1.20044.10.7.2 pm1001lhRinvReloadInventory r/w
triggers an inventory reload.
HW platform description: This OID
1.3.6.1.4.1.20044.10.7.3 pm1001lhRinvHwPlatform r contains the description of the
Hardware platform.
Module platform description: This
1.3.6.1.4.1.20044.10.7.4 pm1001lhRinvModulePlatform r OID contains the description of the
Module.
SW platform description: This OID
1.3.6.1.4.1.20044.10.7.5 pm1001lhRinvSwPlatform r contains the description of the
Software platform.
GW platform desciption: This OID
1.3.6.1.4.1.20044.10.7.6 pm1001lhRinvGwPlatform r contains the description of the
Gateware platform.
Inventory for the Client port: This
1.3.6.1.4.1.20044.10.7.7 pm1001lhRinvClient r OID contains the inventory for the
Client port.
Inventory for the Line: This OID
1.3.6.1.4.1.20044.10.7.8 pm1001lhRinvLine r
contains the inventory for the Line.
1.3.6.1.4.1.20044.10.8 pm1001lhdownload
1.3.6.1.4.1.20044.10.8.1 pm1001lhDwlOther
1.3.6.1.4.1.20044.10.8.1.0 pm1001lhDwlrestartProcess
Warm Restart :This OID indicates
1.3.6.1.4.1.20044.10.8.1.0.1 pm1001lhDwlWarmRestartProcessed r that the module last restart was a
Warm RESTART
Cold Restart :This OID indicates that
1.3.6.1.4.1.20044.10.8.1.0.2 pm1001lhDwlColdRestartProcessed r the module last restart was a Cold
RESTART
1.3.6.1.4.1.20044.10.8.1.1 pm1001lhDwlswBanksUsed

Ekinops PM C1001HC(-ETR) documentation


87 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

SW bank 1 active :This OID


indicates the module is working on
1.3.6.1.4.1.20044.10.8.1.1.1 pm1001lhDwlSwBank1Used r SW bank 1 <Help> This status
indicates if the SW bank 1 is active
or standby

SW bank 2 active :This OID


indicates the module is working on
1.3.6.1.4.1.20044.10.8.1.1.2 pm1001lhDwlSwBank2Used r SW bank 2 <Help> This status
indicates if the SW bank 2 is active
or standby

SW bank 1 loaded :This OID


indicates a software is loaded in SW
1.3.6.1.4.1.20044.10.8.1.1.5 pm1001lhDwlSwBank1Notempty r bank 1 <Help> This status indicates
if the SW bank 1 contains SW
package

SW bank 2 loaded :This OID


indicates a software is loaded in SW
1.3.6.1.4.1.20044.10.8.1.1.6 pm1001lhDwlSwBank2Notempty r bank 2 <Help> This status indicates
if the SW bank 2 contains SW
package

1.3.6.1.4.1.20044.10.8.1.2 pm1001lhDwlgwBanksUsed

GW bank 1 active :This OID


indicates the module is working on
1.3.6.1.4.1.20044.10.8.1.2.1 pm1001lhDwlGwBank1Used r GW bank 1 <Help> This status
indicates if the GW bank 1 is active
or standby

GW bank 3 active :This OID


indicates the module is working on
1.3.6.1.4.1.20044.10.8.1.2.3 pm1001lhDwlGwBank3Used r GW bank 3 <Help> This status
indicates if the GW bank 3 is active
or standby

GW bank 1 loaded :This OID


indicates a gateware is loaded in
1.3.6.1.4.1.20044.10.8.1.2.5 pm1001lhDwlGwBank1Notempty r GW bank 1 <Help> This status
indicates if the GW bank 1 contains
GW package

GW bank 3 loaded :This OID


indicates a gateware is loaded in
1.3.6.1.4.1.20044.10.8.1.2.7 pm1001lhDwlGwBank3Notempty r GW bank 3 <Help> This status
indicates if the GW bank 3 contains
GW package

1.3.6.1.4.1.20044.10.8.2 pm1001lhDwlClient
1.3.6.1.4.1.20044.10.8.3 pm1001lhDwlLine
1.3.6.1.4.1.20044.10.10 pm1001lhConfig
1.3.6.1.4.1.20044.10.10.1 pm1001lhCfgAccessCAisCsf
1.3.6.1.4.1.20044.10.10.1.1 pm1001lhCfgClientcaiscsfTable n/a List of Article
Row definition for the accessCAisCsf
1.3.6.1.4.1.20044.10.10.1.1.1 pm1001lhCfgClientcaiscsfEntry n/a
table
Index definition for the clientcaiscsf
1.3.6.1.4.1.20044.10.10.1.1.1.1 pm1001lhCfgClientcaiscsfIndex r
table
CAIS mode on Client Port :This
register enables/disables port laser
1.3.6.1.4.1.20044.10.10.1.1.1.3 pm1001lhCfgCAisModePortn r/w
shutdown on CAIS insertion
condition

CSF contributors on Client Port :This


register configures the contributors
1.3.6.1.4.1.20044.10.10.1.1.1.9 pm1001lhCfgUpAccessioAlmPortn r/w
to upstream CSF insertion on the
port.

Ekinops PM C1001HC(-ETR) documentation


88 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

CSF contributors on Client Port :This


register configures the contributors
1.3.6.1.4.1.20044.10.10.1.1.1.10 pm1001lhCfgUpMapperDeAlmPortn r/w
to upstream CSF insertion on the
port.

CAIS contributors on Client Port


:This register configures the
1.3.6.1.4.1.20044.10.10.1.1.1.17 pm1001lhCfgDownAccessioAlmPortn r/w
contributors to downstream CAIS
insertion on port.

CAIS contributors on Client Port


:This register configures the
1.3.6.1.4.1.20044.10.10.1.1.1.18 pm1001lhCfgDownMapperDeAlmPortn r/w
contributors to downstream CAIS
insertion on port.

CAIS contributors on Client Port


:This register configures the
1.3.6.1.4.1.20044.10.10.1.1.1.19 pm1001lhCfgDownDfrmAlmPortn r/w
contributors to downstream CAIS
insertion on port.

1.3.6.1.4.1.20044.10.10.2 pm1001lhCfgStartup
1.3.6.1.4.1.20044.10.10.2.1 pm1001lhCfgClientStartupTable n/a List of Article
1.3.6.1.4.1.20044.10.10.2.1.1 pm1001lhCfgClientStartupEntry n/a Row definition for the startup table
Index definition for the clientStartup
1.3.6.1.4.1.20044.10.10.2.1.1.1 pm1001lhCfgClientStartupIndex r
table
Default Settings on Client Port :This
1.3.6.1.4.1.20044.10.10.2.1.1.3 pm1001lhCfgSystConfPortPortn r/w register configures the default
initialisation settings on the port.
Default Protocol on Client Port :This
1.3.6.1.4.1.20044.10.10.2.1.1.4 pm1001lhCfgNetConfPortPortn r/w register configures the default
initialisation protocol on the port.
Default Options on Client Port :This
1.3.6.1.4.1.20044.10.10.2.1.1.6 pm1001lhCfgPortsOptionsPortn r/w register configures the default
options on the client port
1.3.6.1.4.1.20044.10.10.2.2 pm1001lhtablelineStartup
Default Settings on Line 1 :This
1.3.6.1.4.1.20044.10.10.2.2.2 pm1001lhCfgsynthTransLine r/w register configures the default
initialisation settings on Line port 1.
Default Options on Active Line Port
1.3.6.1.4.1.20044.10.10.2.2.5 pm1001lhCfglineOptions1 r/w :This register configures the default
options on the active line port
1.3.6.1.4.1.20044.10.10.2.3 pm1001lhCfgXfpTable n/a List of Article
1.3.6.1.4.1.20044.10.10.2.3.1 pm1001lhCfgXfpEntry n/a Row definition for the startup table
1.3.6.1.4.1.20044.10.10.2.3.1.1 pm1001lhCfgXfpIndex r Index definition for the xfp table
Default settings on XFP Port :This
1.3.6.1.4.1.20044.10.10.2.3.1.3 pm1001lhCfgSystConfXfpPortn r/w register configures the default
initialisation settings on XFP port.
1.3.6.1.4.1.20044.10.10.2.4 pm1001lhCfgOtxtlhTable n/a List of Article
1.3.6.1.4.1.20044.10.10.2.4.1 pm1001lhCfgOtxtlhEntry n/a Row definition for the startup table
1.3.6.1.4.1.20044.10.10.2.4.1.1 pm1001lhCfgOtxtlhIndex r Index definition for the otxtlh table

Default Line OTX TLH FM amplitude


:This register configures the start-up
1.3.6.1.4.1.20044.10.10.2.4.1.4 pm1001lhCfgLineDitherRatePortn r/w
width of the frequency modulation of
the Line OTX TLH

Default Line OTX TLH FM frequency


:This register configures the start-up
1.3.6.1.4.1.20044.10.10.2.4.1.5 pm1001lhCfgLineDitherFhzPortn r/w
frequency of the frequency
modulation of the Line OTX TLH

Ekinops PM C1001HC(-ETR) documentation


89 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Defaut Line OTX TLH output Power


:This register configures the start-up
1.3.6.1.4.1.20044.10.10.2.4.1.6 pm1001lhCfgLinePwrLaserPortn r/w
output power of the Line OTX TLH
(Unit = dBm)

Default Line OTX TLH Channel :This


1.3.6.1.4.1.20044.10.10.2.4.1.7 pm1001lhCfgLineFCurrentPortn r/w register configures the start-up laser
channel of the Line OTX TLH
Default Line OTX TLH Grid :This
1.3.6.1.4.1.20044.10.10.2.4.1.8 pm1001lhCfgLineGridCurrentPortn r/w register configures the start-up laser
grid of the Line OTX TLH

Default Line OTX TLH lowest Freq


:This register configures the start-up
1.3.6.1.4.1.20044.10.10.2.4.1.9 pm1001lhCfgFPortn r/w
lowest frequency supported on the
Line OTX TLH

Default Line OTX TLH APD mode


1.3.6.1.4.1.20044.10.10.2.4.1.11 pm1001lhCfgLinePhotodiodeModePortn r/w :This register configures the start-up
APD mode of the Line OTX TLH

Default Line OTX TLH APD atten.


:This register configures the start-up
1.3.6.1.4.1.20044.10.10.2.4.1.12 pm1001lhCfgLinePhotodiodeValuePortn r/w
APD attenuation on the Line OTX
TLH

1.3.6.1.4.1.20044.10.10.3 pm1001lhCfgLabels
1.3.6.1.4.1.20044.10.10.3.1 pm1001lhCfgLabelclientTable n/a List of Article
1.3.6.1.4.1.20044.10.10.3.1.1 pm1001lhCfgLabelclientEntry n/a Row definition for the labels table
Index definition for the labelclient
1.3.6.1.4.1.20044.10.10.3.1.1.1 pm1001lhCfgLabelclientIndex r
table
Default settings on the label of the
Ports :These registers configures the
1.3.6.1.4.1.20044.10.10.3.1.1.3 pm1001lhCfgLabelclientPortn r/w
default initialisation settings of the
labels of the ports.

1.3.6.1.4.1.20044.10.10.3.2 pm1001lhCfgLabellineTable n/a List of Article


1.3.6.1.4.1.20044.10.10.3.2.1 pm1001lhCfgLabellineEntry n/a Row definition for the labels table
1.3.6.1.4.1.20044.10.10.3.2.1.1 pm1001lhCfgLabellineIndex r Index definition for the labelline table

Default settings on the label of the


lines :These registers configures the
1.3.6.1.4.1.20044.10.10.3.2.1.3 pm1001lhCfgLabellinePortn r/w
default initialisation settings of the
labels of the lines.

Write configuration to module:This


1.3.6.1.4.1.20044.10.10.257 pm1001lhCfgWriteConfiguration r/w OID writes the complete
configuration to the module
1.3.6.1.4.1.20044.10.11 pm1001lhtraps
1.3.6.1.4.1.20044.10.11.1 pm1001lhtrapBoardNumber r Last module which generates a trap
1.3.6.1.4.1.20044.10.12 pm1001lhMonitoring
1.3.6.1.4.1.20044.10.12.1 pm1001lhMonOther
1.3.6.1.4.1.20044.10.12.1.1 pm1001lhMonSync

Perf. Mon. 15-min sync. :This OID


must be used in external
1.3.6.1.4.1.20044.10.12.1.1.259 pm1001lhPerf15minSync r/w
synchronisation mode only to send a
15-min synchronisation command

Perf. Mon. 24-hours sync. :This OID


must be used in external
1.3.6.1.4.1.20044.10.12.1.1.260 pm1001lhPerf24hSync r/w
synchronisation mode only to send a
24-hours synchronisation command

1.3.6.1.4.1.20044.10.12.1.2 pm1001lhMonTimeStamp

Ekinops PM C1001HC(-ETR) documentation


90 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

15-min period is short :This OID


1.3.6.1.4.1.20044.10.12.1.2.1 pm1001lhPerf15MinShort r/w indicates that the 15-min period lasts
less than 890 seconds
15-min period is long :This OID
1.3.6.1.4.1.20044.10.12.1.2.2 pm1001lhPerf15MinLong r/w indicates that the 15-min period lasts
more than 910 seconds
24-hours period is short :This OID
1.3.6.1.4.1.20044.10.12.1.2.5 pm1001lhPerf24HoursShort r/w indicates that 24-hours period lasts
less than 86390 seconds
24-hours period is long :This OID
1.3.6.1.4.1.20044.10.12.1.2.6 pm1001lhPerf24HoursLong r/w indicates that 24-hours period lasts
more than 86410 seconds

Current 15min period Elapsed Time


:This OID gives the number of
1.3.6.1.4.1.20044.10.12.1.2.7 pm1001lhPerfCurrent15MinElapsedTime r/w
seconds elapsed in the current 15-
minutes period

Current 24hours period Elapsed


Time :This OID gives the number of
1.3.6.1.4.1.20044.10.12.1.2.8 pm1001lhPerfCurrent24HoursElapsedTime r/w
seconds elapsed in the current 24-
hours period

1.3.6.1.4.1.20044.10.12.2 pm1001lhMonClient
List of
1.3.6.1.4.1.20044.10.12.2.16 pm1001lhPerfTelecomClientCurrent15StatTable n/a pm1001lhPerfTelecomClientCurrent
15Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.2.16.1 pm1001lhPerfTelecomClientCurrent15StatEntry n/a pm1001lhPerfTelecomClientCurrent
15Stat table
Index definition for the
1.3.6.1.4.1.20044.10.12.2.16.1.1 pm1001lhPerfTelecomClientCurrent15StatIndex r pm1001lhPerfTelecomClientCurrent
15Stat table
Current 15-min CV counter inv. :This
1.3.6.1.4.1.20044.10.12.2.16.1.2 pm1001lhPerfTelecomClientCurrent15StatInvCvPortn r OID indicates that the current 15-min
Coding Violation counter is invalid
Current 15-min CV counter :This
1.3.6.1.4.1.20044.10.12.2.16.1.3 pm1001lhPerfTelecomClientCurrent15StatCvValuePortn r OID gives the current 15-min Coding
Violation counter value
Current 15-min ES counter inv. :This
1.3.6.1.4.1.20044.10.12.2.16.1.4 pm1001lhPerfTelecomClientCurrent15StatInvEsPortn r OID indicates that the current 15-min
Errored Second counter is invalid
Current 15-min ES counter :This OID
1.3.6.1.4.1.20044.10.12.2.16.1.5 pm1001lhPerfTelecomClientCurrent15StatEsValuePortn r gives the current 15-min Errored
Second counter value

Current 15-min SES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.16.1.6 pm1001lhPerfTelecomClientCurrent15StatInvSesPortn r
15-min severely Errored Second
counter is invalid

Current 15-min SES counter :This


pm1001lhPerfTelecomClientCurrent15StatSesValuePort OID gives the current 15-min
1.3.6.1.4.1.20044.10.12.2.16.1.7 r
n severely Errored Second counter
value

Current 15-min SEFS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.16.1.8 pm1001lhPerfTelecomClientCurrent15StatInvSefsPortn r
15-min severely Errored Framing
Second counter is invalid

Current 15-min SEFS counter :This


pm1001lhPerfTelecomClientCurrent15StatSefsValuePort OID gives the current 15-min
1.3.6.1.4.1.20044.10.12.2.16.1.9 r
n severely Errored Framing Second
counter value

Ekinops PM C1001HC(-ETR) documentation


91 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Current 15-min UAS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.16.1.10 pm1001lhPerfTelecomClientCurrent15StatInvUasPortn r
15-min UnAvailable Second counter
is invalid

Current 15-min UAS counter :This


pm1001lhPerfTelecomClientCurrent15StatUasValuePort
1.3.6.1.4.1.20044.10.12.2.16.1.11 r OID gives the current 15-min
n
UnAvailable Second counter value
List of
pm1001lhPerfTelecomClientPast15StatHistoryPort1Tabl
1.3.6.1.4.1.20044.10.12.2.24 n/a pm1001lhPerfTelecomClientPast15S
e
tatHistory Article
Row definition for the
pm1001lhPerfTelecomClientPast15StatHistoryPort1Entr
1.3.6.1.4.1.20044.10.12.2.24.1 n/a pm1001lhPerfTelecomClientPast15S
y
tatHistory table
Index definition for the
pm1001lhPerfTelecomClientPast15StatHistoryPort1Inde
1.3.6.1.4.1.20044.10.12.2.24.1.1 r pm1001lhPerfTelecomClientPast15S
x
tatHistory table

Previous 15-min CV counter inv.


pm1001lhPerfTelecomClientPast15StatHistoryInvCvPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.24.1.2 r
1 15-min Coding Violation counter is
invalid

Previous 15-min CV counter :This


pm1001lhPerfTelecomClientPast15StatHistoryCvValueP
1.3.6.1.4.1.20044.10.12.2.24.1.3 r OID gives the previous 15-min
ort1
Coding Violation counter value

Previous 15-min ES counter inv.


pm1001lhPerfTelecomClientPast15StatHistoryInvEsPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.24.1.4 r
1 15-min Errored Second counter is
invalid

Previous 15-min ES counter :This


pm1001lhPerfTelecomClientPast15StatHistoryEsValueP
1.3.6.1.4.1.20044.10.12.2.24.1.5 r OID gives the previous 15-min
ort1
Errored Second counter value

Previous 15-min SES counter inv.


pm1001lhPerfTelecomClientPast15StatHistoryInvSesPor :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.24.1.6 r
t1 15-min severely Errored Second
counter is invalid

Previous 15-min SES counter :This


pm1001lhPerfTelecomClientPast15StatHistorySesValue OID gives the previous 15-min
1.3.6.1.4.1.20044.10.12.2.24.1.7 r
Port1 severely Errored Second counter
value

Previous 15-min SEFS counter inv.


pm1001lhPerfTelecomClientPast15StatHistoryInvSefsPo :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.24.1.8 r
rt1 15-min severely Errored Framing
Second counter is invalid

Previous 15-min SEFS counter :This


pm1001lhPerfTelecomClientPast15StatHistorySefsValue OID gives the previous 15-min
1.3.6.1.4.1.20044.10.12.2.24.1.9 r
Port1 severely Errored Framing Second
counter value

Previous 15-min UAS counter inv.


pm1001lhPerfTelecomClientPast15StatHistoryInvUasPo :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.24.1.10 r
rt1 15-min UnAvailable Second counter
is invalid

Previous 15-min UAS counter :This


pm1001lhPerfTelecomClientPast15StatHistoryUasValue
1.3.6.1.4.1.20044.10.12.2.24.1.11 r OID gives the previous 15-min
Port1
UnAvailable Second counter value
List of
1.3.6.1.4.1.20044.10.12.2.32 pm1001lhPerfTelecomClientCurrent24StatTable n/a pm1001lhPerfTelecomClientCurrent
24Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.2.32.1 pm1001lhPerfTelecomClientCurrent24StatEntry n/a pm1001lhPerfTelecomClientCurrent
24Stat table

Ekinops PM C1001HC(-ETR) documentation


92 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Index definition for the


1.3.6.1.4.1.20044.10.12.2.32.1.1 pm1001lhPerfTelecomClientCurrent24StatIndex r pm1001lhPerfTelecomClientCurrent
24Stat table

Current 24-hours CV counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.32.1.2 pm1001lhPerfTelecomClientCurrent24StatInvCvPortn r
24-hours Coding Violation counter is
invalid

Current 24-hours CV counter :This


1.3.6.1.4.1.20044.10.12.2.32.1.3 pm1001lhPerfTelecomClientCurrent24StatCvValuePortn r OID gives the current 24-hours
Coding Violation counter value

Current 24-hours ES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.32.1.4 pm1001lhPerfTelecomClientCurrent24StatInvEsPortn r
24-hours Errored Second counter is
invalid

Current 24-hours ES counter :This


1.3.6.1.4.1.20044.10.12.2.32.1.5 pm1001lhPerfTelecomClientCurrent24StatEsValuePortn r OID gives the current 24-hours
Errored Second counter value

Current 24-hours SES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.32.1.6 pm1001lhPerfTelecomClientCurrent24StatInvSesPortn r
24-hours severely Errored Second
counter is invalid

Current 24-hours SES counter :This


pm1001lhPerfTelecomClientCurrent24StatSesValuePort OID gives the current 24-hours
1.3.6.1.4.1.20044.10.12.2.32.1.7 r
n severely Errored Second counter
value

Current 24-hours SEFS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.32.1.8 pm1001lhPerfTelecomClientCurrent24StatInvSefsPortn r
24-hours severely Errored Framing
Second counter is invalid

Current 24-hours SEFS counter


pm1001lhPerfTelecomClientCurrent24StatSefsValuePort :This OID gives the current 24-hours
1.3.6.1.4.1.20044.10.12.2.32.1.9 r
n severely Errored Framing Second
counter value

Current 24-hours UAS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.2.32.1.10 pm1001lhPerfTelecomClientCurrent24StatInvUasPortn r
24-hours UnAvailable Second
counter is invalid

Current 24-hours UAS counter :This


pm1001lhPerfTelecomClientCurrent24StatUasValuePort
1.3.6.1.4.1.20044.10.12.2.32.1.11 r OID gives the current 24-hours
n
UnAvailable Second counter value
List of
pm1001lhPerfTelecomClientPast24StatHistoryPort1Tabl
1.3.6.1.4.1.20044.10.12.2.40 n/a pm1001lhPerfTelecomClientPast24S
e
tatHistory Article
Row definition for the
pm1001lhPerfTelecomClientPast24StatHistoryPort1Entr
1.3.6.1.4.1.20044.10.12.2.40.1 n/a pm1001lhPerfTelecomClientPast24S
y
tatHistory table
Index definition for the
pm1001lhPerfTelecomClientPast24StatHistoryPort1Inde
1.3.6.1.4.1.20044.10.12.2.40.1.1 r pm1001lhPerfTelecomClientPast24S
x
tatHistory table

Previous 24-hours CV counter inv.


pm1001lhPerfTelecomClientPast24StatHistoryInvCvPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.40.1.2 r
1 24-hours Coding Violation counter is
invalid

Previous 24-hours CV counter :This


pm1001lhPerfTelecomClientPast24StatHistoryCvValueP
1.3.6.1.4.1.20044.10.12.2.40.1.3 r OID gives the previous 24-hours
ort1
Coding Violation counter value

Previous 24-hours ES counter inv.


pm1001lhPerfTelecomClientPast24StatHistoryInvEsPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.40.1.4 r
1 24-hours Errored Second counter is
invalid

Ekinops PM C1001HC(-ETR) documentation


93 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Previous 24-hours ES counter :This


pm1001lhPerfTelecomClientPast24StatHistoryEsValueP
1.3.6.1.4.1.20044.10.12.2.40.1.5 r OID gives the previous 24-hours
ort1
Errored Second counter value

Previous 24-hours SES counter inv.


pm1001lhPerfTelecomClientPast24StatHistoryInvSesPor :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.40.1.6 r
t1 24-hours severely Errored Second
counter is invalid

Previous 24-hours SES counter


pm1001lhPerfTelecomClientPast24StatHistorySesValue :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.2.40.1.7 r
Port1 hours severely Errored Second
counter value

Previous 24-hours SEFS counter


pm1001lhPerfTelecomClientPast24StatHistoryInvSefsPo inv. :This OID indicates that the
1.3.6.1.4.1.20044.10.12.2.40.1.8 r
rt1 previous 24-hours severely Errored
Framing Second counter is invalid

Previous 24-hours SEFS counter


pm1001lhPerfTelecomClientPast24StatHistorySefsValue :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.2.40.1.9 r
Port1 hours severely Errored Framing
Second counter value

Previous 24-hours UAS counter inv.


pm1001lhPerfTelecomClientPast24StatHistoryInvUasPo :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.2.40.1.10 r
rt1 24-hours UnAvailable Second
counter is invalid

Previous 24-hours UAS counter


pm1001lhPerfTelecomClientPast24StatHistoryUasValue :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.2.40.1.11 r
Port1 hours UnAvailable Second counter
value

List of
1.3.6.1.4.1.20044.10.12.2.256 pm1001lhPerfDatacomClientCurrent15StatTable n/a pm1001lhPerfDatacomClientCurrent
15Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.2.256.1 pm1001lhPerfDatacomClientCurrent15StatEntry n/a pm1001lhPerfDatacomClientCurrent
15Stat table
Index definition for the
1.3.6.1.4.1.20044.10.12.2.256.1.1 pm1001lhPerfDatacomClientCurrent15StatIndex r pm1001lhPerfDatacomClientCurrent
15Stat table

Client Current 15-min Input Bytes


pm1001lhperfdatacomclientCurrent15StatInBytesCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.2 r
nvPortn the current 15-min Bytes counter is
invalid

Client Current 15-min Input Bytes


pm1001lhperfdatacomclientCurrent15StatInBytesCountP
1.3.6.1.4.1.20044.10.12.2.256.1.3 r counter :This OID gives the current
ortn
15-min Bytes counter value

Client Current 15-min Input CRC


pm1001lhperfdatacomclientCurrent15StatInCrcCountInv counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.4 r
Portn the current 15-min CRC counter is
invalid

Client Current 15-min Input CRC


pm1001lhperfdatacomclientCurrent15StatInCrcCountPor
1.3.6.1.4.1.20044.10.12.2.256.1.5 r counter :This OID gives the current
tn
15-min CRC counter value

Client Current 15-min Input


pm1001lhperfdatacomclientCurrent15StatInBroadcastCo Broadcast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.256.1.8 r
untInvPortn indicates that the current 15-min
Broadcast counter is invalid

Client Current 15-min Input


pm1001lhperfdatacomclientCurrent15StatInBroadcastCo Broadcast counter :This OID gives
1.3.6.1.4.1.20044.10.12.2.256.1.9 r
untPortn the current 15-min Broadcast
counter value

Ekinops PM C1001HC(-ETR) documentation


94 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Current 15-min Input Multicast


pm1001lhperfdatacomclientCurrent15StatInMulticastCou counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.10 r
ntInvPortn the current 15-min Multicast counter
is invalid

Client Current 15-min Input Multicast


pm1001lhperfdatacomclientCurrent15StatInMulticastCou
1.3.6.1.4.1.20044.10.12.2.256.1.11 r counter :This OID gives the current
ntPortn
15-min Multicast counter value

Client Current 15-min Input Unicast


pm1001lhperfdatacomclientCurrent15StatInUnicastCoun counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.20 r
tInvPortn the current 15-min Unicast counter is
invalid

Client Current 15-min Input Unicast


pm1001lhperfdatacomclientCurrent15StatInUnicastCoun
1.3.6.1.4.1.20044.10.12.2.256.1.21 r counter :This OID gives the current
tPortn
15-min Unicast counter value

Client Current 15-min Input Non


pm1001lhperfdatacomclientCurrent15StatInNonunicastC Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.256.1.22 r
ountInvPortn indicates that the current 15-min Non
unicast counter is invalid

Client Current 15-min Input Non


pm1001lhperfdatacomclientCurrent15StatInNonunicastC Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.256.1.23 r
ountPortn current 15-min Non Unicast counter
value

Client Current 15-min Output Bytes


pm1001lhperfdatacomclientCurrent15StatOutBytesCoun counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.26 r
tInvPortn the current 15-min Bytes counter is
invalid

Client Current 15-min Output Bytes


pm1001lhperfdatacomclientCurrent15StatOutBytesCoun
1.3.6.1.4.1.20044.10.12.2.256.1.27 r counter :This OID gives the current
tPortn
15-min Bytes counter value

Client Current 15-min Output


pm1001lhperfdatacomclientCurrent15StatOutBroadcast Broadcast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.256.1.32 r
CountInvPortn indicates that the current 15-min
Broadcast counter is invalid

Client Current 15-min Output


pm1001lhperfdatacomclientCurrent15StatOutBroadcast Broadcast counter :This OID gives
1.3.6.1.4.1.20044.10.12.2.256.1.33 r
CountPortn the current 15-min Broadcast
counter value

Client Current 15-min Output


pm1001lhperfdatacomclientCurrent15StatOutMulticastC Multicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.256.1.34 r
ountInvPortn indicates that the current 15-min
Multicast counter is invalid

Client Current 15-min Output


pm1001lhperfdatacomclientCurrent15StatOutMulticastC Multicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.256.1.35 r
ountPortn current 15-min Multicast counter
value

Client Current 15-min Output Unicast


pm1001lhperfdatacomclientCurrent15StatOutUnicastCo counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.256.1.42 r
untInvPortn the current 15-min Unicast counter is
invalid

Client Current 15-min Output Unicast


pm1001lhperfdatacomclientCurrent15StatOutUnicastCo
1.3.6.1.4.1.20044.10.12.2.256.1.43 r counter :This OID gives the current
untPortn
15-min Unicast counter value

Client Current 15-min Output Non


pm1001lhperfdatacomclientCurrent15StatOutNonunicast Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.256.1.44 r
CountInvPortn indicates that the current 15-min Non
Unicast counter is invalid

Client Current 15-min Output Non


pm1001lhperfdatacomclientCurrent15StatOutNonunicast Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.256.1.45 r
CountPortn current 15-min Non Unicast counter
value

Ekinops PM C1001HC(-ETR) documentation


95 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

List of
pm1001lhPerfDatacomClientPast15StatHistoryPort1Tabl
1.3.6.1.4.1.20044.10.12.2.264 n/a pm1001lhPerfDatacomClientPast15
e
StatHistory Article
Row definition for the
pm1001lhPerfDatacomClientPast15StatHistoryPort1Entr
1.3.6.1.4.1.20044.10.12.2.264.1 n/a pm1001lhPerfDatacomClientPast15
y
StatHistory table
Index definition for the
pm1001lhPerfDatacomClientPast15StatHistoryPort1Inde
1.3.6.1.4.1.20044.10.12.2.264.1.1 r pm1001lhPerfDatacomClientPast15
x
StatHistory table

Client Past 15-min Input Bytes


pm1001lhperfdatacomclientPast15StatInBytesCountInvP counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.2 r
ort1 the past 15-min Bytes counter is
invalid

Client Past 15-min Input Bytes


pm1001lhperfdatacomclientPast15StatInBytesCountPort
1.3.6.1.4.1.20044.10.12.2.264.1.3 r counter :This OID gives the past 15-
1
min Bytes counter value
Client Past 15-min Input CRC
pm1001lhperfdatacomclientPast15StatInCrcCountInvPor counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.4 r
t1 the past 15-min CRC counter is
invalid
Client Past 15-min Input CRC
1.3.6.1.4.1.20044.10.12.2.264.1.5 pm1001lhperfdatacomclientPast15StatInCrcCountPort1 r counter :This OID gives the past 15-
min CRC counter value

Client Past 15-min Input Broadcast


pm1001lhperfdatacomclientPast15StatInBroadcastCount counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.8 r
InvPort1 the past 15-min Broadcast counter is
invalid

Client Past 15-min Input Broadcast


pm1001lhperfdatacomclientPast15StatInBroadcastCount
1.3.6.1.4.1.20044.10.12.2.264.1.9 r counter :This OID gives the past 15-
Port1
min Broadcast counter value

Client Past 15-min Input Multicast


pm1001lhperfdatacomclientPast15StatInMulticastCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.10 r
nvPort1 the past 15-min Multicast counter is
invalid

Client Past 15-min Input Multicast


pm1001lhperfdatacomclientPast15StatInMulticastCount
1.3.6.1.4.1.20044.10.12.2.264.1.11 r counter :This OID gives the past 15-
Port1
min Multicast counter value

Client Past 15-min Input Unicast


pm1001lhperfdatacomclientPast15StatInUnicastCountIn counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.20 r
vPort1 the past 15-min Unicast counter is
invalid

Client Past 15-min Input Unicast


pm1001lhperfdatacomclientPast15StatInUnicastCountPo
1.3.6.1.4.1.20044.10.12.2.264.1.21 r counter :This OID gives the past 15-
rt1
min Unicast counter value

Client Past 15-min Input Non Unicast


pm1001lhperfdatacomclientPast15StatInNonunicastCou counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.22 r
ntInvPort1 the past 15-min Non unicast counter
is invalid

Client Past 15-min Input Non Unicast


pm1001lhperfdatacomclientPast15StatInNonunicastCou
1.3.6.1.4.1.20044.10.12.2.264.1.23 r counter :This OID gives the past 15-
ntPort1
min Non Unicast counter value

Client Past 15-min Output Bytes


pm1001lhperfdatacomclientPast15StatOutBytesCountIn counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.26 r
vPort1 the past 15-min Bytes counter is
invalid

Client Past 15-min Output Bytes


pm1001lhperfdatacomclientPast15StatOutBytesCountPo
1.3.6.1.4.1.20044.10.12.2.264.1.27 r counter :This OID gives the past 15-
rt1
min Bytes counter value

Ekinops PM C1001HC(-ETR) documentation


96 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Past 15-min Output Broadcast


pm1001lhperfdatacomclientPast15StatOutBroadcastCou counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.32 r
ntInvPort1 the past 15-min Broadcast counter is
invalid

Client Past 15-min Output Broadcast


pm1001lhperfdatacomclientPast15StatOutBroadcastCou
1.3.6.1.4.1.20044.10.12.2.264.1.33 r counter :This OID gives the past 15-
ntPort1
min Broadcast counter value

Client Past 15-min Output Multicast


pm1001lhperfdatacomclientPast15StatOutMulticastCoun counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.34 r
tInvPort1 the past 15-min Multicast counter is
invalid

Client Past 15-min Output Multicast


pm1001lhperfdatacomclientPast15StatOutMulticastCoun
1.3.6.1.4.1.20044.10.12.2.264.1.35 r counter :This OID gives the past 15-
tPort1
min Multicast counter value

Client Past 15-min Output Unicast


pm1001lhperfdatacomclientPast15StatOutUnicastCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.264.1.42 r
nvPort1 the past 15-min Unicast counter is
invalid

Client Past 15-min Output Unicast


pm1001lhperfdatacomclientPast15StatOutUnicastCount
1.3.6.1.4.1.20044.10.12.2.264.1.43 r counter :This OID gives the past 15-
Port1
min Unicast counter value

Client Past 15-min Output Non


pm1001lhperfdatacomclientPast15StatOutNonunicastCo Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.264.1.44 r
untInvPort1 indicates that the past 15-min Non
Unicast counter is invalid

Client Past 15-min Output Non


pm1001lhperfdatacomclientPast15StatOutNonunicastCo Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.264.1.45 r
untPort1 past 15-min Non Unicast counter
value

List of
1.3.6.1.4.1.20044.10.12.2.272 pm1001lhPerfDatacomClientCurrent24StatTable n/a pm1001lhPerfDatacomClientCurrent
24Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.2.272.1 pm1001lhPerfDatacomClientCurrent24StatEntry n/a pm1001lhPerfDatacomClientCurrent
24Stat table
Index definition for the
1.3.6.1.4.1.20044.10.12.2.272.1.1 pm1001lhPerfDatacomClientCurrent24StatIndex r pm1001lhPerfDatacomClientCurrent
24Stat table

Client Current 24-hours Input Bytes


pm1001lhperfdatacomclientCurrent24StatInBytesCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.272.1.2 r
nvPortn the current 24-hours Bytes counter is
invalid

Client Current 24-hours Input Bytes


pm1001lhperfdatacomclientCurrent24StatInBytesCountP
1.3.6.1.4.1.20044.10.12.2.272.1.3 r counter :This OID gives the current
ortn
24-hours Bytes counter value

Client Current 24-hours Input CRC


pm1001lhperfdatacomclientCurrent24StatInCrcCountInv counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.272.1.4 r
Portn the current 24-hours CRC counter is
invalid

Client Current 24-hours Input CRC


pm1001lhperfdatacomclientCurrent24StatInCrcCountPor
1.3.6.1.4.1.20044.10.12.2.272.1.5 r counter :This OID gives the current
tn
24-hours CRC counter value

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInBroadcastCo Broadcast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.8 r
untInvPortn indicates that the current 24-hours
Broadcast counter is invalid

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInBroadcastCo Broadcast counter :This OID gives
1.3.6.1.4.1.20044.10.12.2.272.1.9 r
untPortn the current 24-hours Broadcast
counter value

Ekinops PM C1001HC(-ETR) documentation


97 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInMulticastCou Multicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.10 r
ntInvPortn indicates that the current 24-hours
Multicast counter is invalid

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInMulticastCou Multicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.11 r
ntPortn current 24-hours Multicast counter
value

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInUnicastCoun Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.20 r
tInvPortn indicates that the current 24-hours
Unicast counter is invalid

Client Current 24-hours Input


pm1001lhperfdatacomclientCurrent24StatInUnicastCoun Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.21 r
tPortn current 24-hours Unicast counter
value

Client Current 24-hours Input Non


pm1001lhperfdatacomclientCurrent24StatInNonunicastC Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.22 r
ountInvPortn indicates that the current 24-hours
Non unicast counter is invalid

Client Current 24-hours Input Non


pm1001lhperfdatacomclientCurrent24StatInNonunicastC Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.23 r
ountPortn current 24-hours Non Unicast
counter value

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutBytesCoun Bytes counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.26 r
tInvPortn indicates that the current 24-hours
Bytes counter is invalid

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutBytesCoun
1.3.6.1.4.1.20044.10.12.2.272.1.27 r Bytes counter :This OID gives the
tPortn
current 24-hours Bytes counter value

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutBroadcast Broadcast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.32 r
CountInvPortn indicates that the current 24-hours
Broadcast counter is invalid

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutBroadcast Broadcast counter :This OID gives
1.3.6.1.4.1.20044.10.12.2.272.1.33 r
CountPortn the current 24-hours Broadcast
counter value

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutMulticastC Multicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.34 r
ountInvPortn indicates that the current 24-hours
Multicast counter is invalid

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutMulticastC Multicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.35 r
ountPortn current 24-hours Multicast counter
value

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutUnicastCo Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.42 r
untInvPortn indicates that the current 24-hours
Unicast counter is invalid

Client Current 24-hours Output


pm1001lhperfdatacomclientCurrent24StatOutUnicastCo Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.43 r
untPortn current 24-hours Unicast counter
value

Client Current 24-hours Output Non


pm1001lhperfdatacomclientCurrent24StatOutNonunicast Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.272.1.44 r
CountInvPortn indicates that the current 24-hours
Non Unicast counter is invalid

Ekinops PM C1001HC(-ETR) documentation


98 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Current 24-hours Output Non


pm1001lhperfdatacomclientCurrent24StatOutNonunicast Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.272.1.45 r
CountPortn current 24-hours Non Unicast
counter value

List of
pm1001lhPerfDatacomClientPast24StatHistoryPort1Tabl
1.3.6.1.4.1.20044.10.12.2.280 n/a pm1001lhPerfDatacomClientPast24
e
StatHistory Article
Row definition for the
pm1001lhPerfDatacomClientPast24StatHistoryPort1Entr
1.3.6.1.4.1.20044.10.12.2.280.1 n/a pm1001lhPerfDatacomClientPast24
y
StatHistory table
Index definition for the
pm1001lhPerfDatacomClientPast24StatHistoryPort1Inde
1.3.6.1.4.1.20044.10.12.2.280.1.1 r pm1001lhPerfDatacomClientPast24
x
StatHistory table

Client Past 24-hours Input Bytes


pm1001lhperfdatacomclientPast24StatInBytesCountInvP counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.2 r
ort1 the past 24-hours Bytes counter is
invalid

Client Past 24-hours Input Bytes


pm1001lhperfdatacomclientPast24StatInBytesCountPort
1.3.6.1.4.1.20044.10.12.2.280.1.3 r counter :This OID gives the past 24-
1
hours Bytes counter value

Client Past 24-hours Input CRC


pm1001lhperfdatacomclientPast24StatInCrcCountInvPor counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.4 r
t1 the past 24-hours CRC counter is
invalid

Client Past 24-hours Input CRC


1.3.6.1.4.1.20044.10.12.2.280.1.5 pm1001lhperfdatacomclientPast24StatInCrcCountPort1 r counter :This OID gives the past 24-
hours CRC counter value

Client Past 24-hours Input Broadcast


pm1001lhperfdatacomclientPast24StatInBroadcastCount counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.8 r
InvPort1 the past 24-hours Broadcast counter
is invalid

Client Past 24-hours Input Broadcast


pm1001lhperfdatacomclientPast24StatInBroadcastCount
1.3.6.1.4.1.20044.10.12.2.280.1.9 r counter :This OID gives the past 24-
Port1
hours Broadcast counter value

Client Past 24-hours Input Multicast


pm1001lhperfdatacomclientPast24StatInMulticastCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.10 r
nvPort1 the past 24-hours Multicast counter
is invalid

Client Past 24-hours Input Multicast


pm1001lhperfdatacomclientPast24StatInMulticastCount
1.3.6.1.4.1.20044.10.12.2.280.1.11 r counter :This OID gives the past 24-
Port1
hours Multicast counter value

Client Past 24-hours Input Unicast


pm1001lhperfdatacomclientPast24StatInUnicastCountIn counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.20 r
vPort1 the past 24-hours Unicast counter is
invalid

Client Past 24-hours Input Unicast


pm1001lhperfdatacomclientPast24StatInUnicastCountPo
1.3.6.1.4.1.20044.10.12.2.280.1.21 r counter :This OID gives the past 24-
rt1
hours Unicast counter value

Client Past 24-hours Input Non


pm1001lhperfdatacomclientPast24StatInNonunicastCou Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.280.1.22 r
ntInvPort1 indicates that the past 24-hours Non
unicast counter is invalid

Client Past 24-hours Input Non


pm1001lhperfdatacomclientPast24StatInNonunicastCou Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.280.1.23 r
ntPort1 past 24-hours Non Unicast counter
value

Ekinops PM C1001HC(-ETR) documentation


99 / 111
Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Client Past 24-hours Output Bytes


pm1001lhperfdatacomclientPast24StatOutBytesCountIn counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.26 r
vPort1 the past 24-hours Bytes counter is
invalid

Client Past 24-hours Output Bytes


pm1001lhperfdatacomclientPast24StatOutBytesCountPo
1.3.6.1.4.1.20044.10.12.2.280.1.27 r counter :This OID gives the past 24-
rt1
hours Bytes counter value

Client Past 24-hours Output


pm1001lhperfdatacomclientPast24StatOutBroadcastCou Broadcast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.280.1.32 r
ntInvPort1 indicates that the past 24-hours
Broadcast counter is invalid

Client Past 24-hours Output


pm1001lhperfdatacomclientPast24StatOutBroadcastCou Broadcast counter :This OID gives
1.3.6.1.4.1.20044.10.12.2.280.1.33 r
ntPort1 the past 24-hours Broadcast counter
value

Client Past 24-hours Output


pm1001lhperfdatacomclientPast24StatOutMulticastCoun Multicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.280.1.34 r
tInvPort1 indicates that the past 24-hours
Multicast counter is invalid

Client Past 24-hours Output


pm1001lhperfdatacomclientPast24StatOutMulticastCoun Multicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.280.1.35 r
tPort1 past 24-hours Multicast counter
value

Client Past 24-hours Output Unicast


pm1001lhperfdatacomclientPast24StatOutUnicastCountI counter inv. :This OID indicates that
1.3.6.1.4.1.20044.10.12.2.280.1.42 r
nvPort1 the past 24-hours Unicast counter is
invalid

Client Past 24-hours Output Unicast


pm1001lhperfdatacomclientPast24StatOutUnicastCount
1.3.6.1.4.1.20044.10.12.2.280.1.43 r counter :This OID gives the past 24-
Port1
hours Unicast counter value

Client Past 24-hours Output Non


pm1001lhperfdatacomclientPast24StatOutNonunicastCo Unicast counter inv. :This OID
1.3.6.1.4.1.20044.10.12.2.280.1.44 r
untInvPort1 indicates that the past 24-hours Non
Unicast counter is invalid

Client Past 24-hours Output Non


pm1001lhperfdatacomclientPast24StatOutNonunicastCo Unicast counter :This OID gives the
1.3.6.1.4.1.20044.10.12.2.280.1.45 r
untPort1 past 24-hours Non Unicast counter
value

1.3.6.1.4.1.20044.10.12.3 pm1001lhMonLine
List of
1.3.6.1.4.1.20044.10.12.3.128 pm1001lhPerfTelecomLineCurrent15StatTable n/a pm1001lhPerfTelecomLineCurrent15
Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.3.128.1 pm1001lhPerfTelecomLineCurrent15StatEntry n/a pm1001lhPerfTelecomLineCurrent15
Stat table
Index definition for the
1.3.6.1.4.1.20044.10.12.3.128.1.1 pm1001lhPerfTelecomLineCurrent15StatIndex r pm1001lhPerfTelecomLineCurrent15
Stat table
Current 15-min CV counter inv. :This
1.3.6.1.4.1.20044.10.12.3.128.1.2 pm1001lhPerfTelecomLineCurrent15StatInvCvPortn r OID indicates that the current 15-min
Coding Violation counter is invalid
Current 15-min CV counter :This
1.3.6.1.4.1.20044.10.12.3.128.1.3 pm1001lhPerfTelecomLineCurrent15StatCvValuePortn r OID gives the current 15-min Coding
Violation counter value
Current 15-min ES counter inv. :This
1.3.6.1.4.1.20044.10.12.3.128.1.4 pm1001lhPerfTelecomLineCurrent15StatInvEsPortn r OID indicates that the current 15-min
Errored Second counter is invalid
Current 15-min ES counter :This OID
1.3.6.1.4.1.20044.10.12.3.128.1.5 pm1001lhPerfTelecomLineCurrent15StatEsValuePortn r gives the current 15-min Errored
Second counter value

Ekinops PM C1001HC(-ETR) documentation 100 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Current 15-min SES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.128.1.6 pm1001lhPerfTelecomLineCurrent15StatInvSesPortn r
15-min severely Errored Second
counter is invalid

Current 15-min SES counter :This


OID gives the current 15-min
1.3.6.1.4.1.20044.10.12.3.128.1.7 pm1001lhPerfTelecomLineCurrent15StatSesValuePortn r
severely Errored Second counter
value

Current 15-min SEFS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.128.1.8 pm1001lhPerfTelecomLineCurrent15StatInvSefsPortn r
15-min severely Errored Framing
Second counter is invalid

Current 15-min SEFS counter :This


OID gives the current 15-min
1.3.6.1.4.1.20044.10.12.3.128.1.9 pm1001lhPerfTelecomLineCurrent15StatSefsValuePortn r
severely Errored Framing Second
counter value

Current 15-min UAS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.128.1.10 pm1001lhPerfTelecomLineCurrent15StatInvUasPortn r
15-min UnAvailable Second counter
is invalid

Current 15-min UAS counter :This


1.3.6.1.4.1.20044.10.12.3.128.1.11 pm1001lhPerfTelecomLineCurrent15StatUasValuePortn r OID gives the current 15-min
UnAvailable Second counter value
List of
1.3.6.1.4.1.20044.10.12.3.129 pm1001lhPerfTelecomLinePast15StatHistoryPort1Table n/a pm1001lhPerfTelecomLinePast15St
atHistory Article
Row definition for the
1.3.6.1.4.1.20044.10.12.3.129.1 pm1001lhPerfTelecomLinePast15StatHistoryPort1Entry n/a pm1001lhPerfTelecomLinePast15St
atHistory table
Index definition for the
1.3.6.1.4.1.20044.10.12.3.129.1.1 pm1001lhPerfTelecomLinePast15StatHistoryPort1Index r pm1001lhPerfTelecomLinePast15St
atHistory table

Previous 15-min CV counter inv.


:This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.129.1.2 pm1001lhPerfTelecomLinePast15StatHistoryInvCvPort1 r
15-min Coding Violation counter is
invalid

Previous 15-min CV counter :This


pm1001lhPerfTelecomLinePast15StatHistoryCvValuePo
1.3.6.1.4.1.20044.10.12.3.129.1.3 r OID gives the previous 15-min
rt1
Coding Violation counter value

Previous 15-min ES counter inv.


:This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.129.1.4 pm1001lhPerfTelecomLinePast15StatHistoryInvEsPort1 r
15-min Errored Second counter is
invalid

Previous 15-min ES counter :This


pm1001lhPerfTelecomLinePast15StatHistoryEsValuePor
1.3.6.1.4.1.20044.10.12.3.129.1.5 r OID gives the previous 15-min
t1
Errored Second counter value

Previous 15-min SES counter inv.


pm1001lhPerfTelecomLinePast15StatHistoryInvSesPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.129.1.6 r
1 15-min severely Errored Second
counter is invalid

Previous 15-min SES counter :This


pm1001lhPerfTelecomLinePast15StatHistorySesValueP OID gives the previous 15-min
1.3.6.1.4.1.20044.10.12.3.129.1.7 r
ort1 severely Errored Second counter
value

Previous 15-min SEFS counter inv.


pm1001lhPerfTelecomLinePast15StatHistoryInvSefsPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.129.1.8 r
1 15-min severely Errored Framing
Second counter is invalid

Ekinops PM C1001HC(-ETR) documentation 101 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Previous 15-min SEFS counter :This


pm1001lhPerfTelecomLinePast15StatHistorySefsValueP OID gives the previous 15-min
1.3.6.1.4.1.20044.10.12.3.129.1.9 r
ort1 severely Errored Framing Second
counter value

Previous 15-min UAS counter inv.


pm1001lhPerfTelecomLinePast15StatHistoryInvUasPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.129.1.10 r
1 15-min UnAvailable Second counter
is invalid

Previous 15-min UAS counter :This


pm1001lhPerfTelecomLinePast15StatHistoryUasValueP
1.3.6.1.4.1.20044.10.12.3.129.1.11 r OID gives the previous 15-min
ort1
UnAvailable Second counter value
List of
1.3.6.1.4.1.20044.10.12.3.130 pm1001lhPerfTelecomLineCurrent24StatTable n/a pm1001lhPerfTelecomLineCurrent24
Stat Article
Row definition for the
1.3.6.1.4.1.20044.10.12.3.130.1 pm1001lhPerfTelecomLineCurrent24StatEntry n/a pm1001lhPerfTelecomLineCurrent24
Stat table
Index definition for the
1.3.6.1.4.1.20044.10.12.3.130.1.1 pm1001lhPerfTelecomLineCurrent24StatIndex r pm1001lhPerfTelecomLineCurrent24
Stat table

Current 24-hours CV counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.130.1.2 pm1001lhPerfTelecomLineCurrent24StatInvCvPortn r
24-hours Coding Violation counter is
invalid

Current 24-hours CV counter :This


1.3.6.1.4.1.20044.10.12.3.130.1.3 pm1001lhPerfTelecomLineCurrent24StatCvValuePortn r OID gives the current 24-hours
Coding Violation counter value

Current 24-hours ES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.130.1.4 pm1001lhPerfTelecomLineCurrent24StatInvEsPortn r
24-hours Errored Second counter is
invalid

Current 24-hours ES counter :This


1.3.6.1.4.1.20044.10.12.3.130.1.5 pm1001lhPerfTelecomLineCurrent24StatEsValuePortn r OID gives the current 24-hours
Errored Second counter value

Current 24-hours SES counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.130.1.6 pm1001lhPerfTelecomLineCurrent24StatInvSesPortn r
24-hours severely Errored Second
counter is invalid

Current 24-hours SES counter :This


OID gives the current 24-hours
1.3.6.1.4.1.20044.10.12.3.130.1.7 pm1001lhPerfTelecomLineCurrent24StatSesValuePortn r
severely Errored Second counter
value

Current 24-hours SEFS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.130.1.8 pm1001lhPerfTelecomLineCurrent24StatInvSefsPortn r
24-hours severely Errored Framing
Second counter is invalid

Current 24-hours SEFS counter


:This OID gives the current 24-hours
1.3.6.1.4.1.20044.10.12.3.130.1.9 pm1001lhPerfTelecomLineCurrent24StatSefsValuePortn r
severely Errored Framing Second
counter value

Current 24-hours UAS counter inv.


:This OID indicates that the current
1.3.6.1.4.1.20044.10.12.3.130.1.10 pm1001lhPerfTelecomLineCurrent24StatInvUasPortn r
24-hours UnAvailable Second
counter is invalid

Current 24-hours UAS counter :This


1.3.6.1.4.1.20044.10.12.3.130.1.11 pm1001lhPerfTelecomLineCurrent24StatUasValuePortn r OID gives the current 24-hours
UnAvailable Second counter value
List of
1.3.6.1.4.1.20044.10.12.3.131 pm1001lhPerfTelecomLinePast24StatHistoryPort1Table n/a pm1001lhPerfTelecomLinePast24St
atHistory Article

Ekinops PM C1001HC(-ETR) documentation 102 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Row definition for the


1.3.6.1.4.1.20044.10.12.3.131.1 pm1001lhPerfTelecomLinePast24StatHistoryPort1Entry n/a pm1001lhPerfTelecomLinePast24St
atHistory table
Index definition for the
1.3.6.1.4.1.20044.10.12.3.131.1.1 pm1001lhPerfTelecomLinePast24StatHistoryPort1Index r pm1001lhPerfTelecomLinePast24St
atHistory table

Previous 24-hours CV counter inv.


:This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.131.1.2 pm1001lhPerfTelecomLinePast24StatHistoryInvCvPort1 r
24-hours Coding Violation counter is
invalid

Previous 24-hours CV counter :This


pm1001lhPerfTelecomLinePast24StatHistoryCvValuePo
1.3.6.1.4.1.20044.10.12.3.131.1.3 r OID gives the previous 24-hours
rt1
Coding Violation counter value

Previous 24-hours ES counter inv.


:This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.131.1.4 pm1001lhPerfTelecomLinePast24StatHistoryInvEsPort1 r
24-hours Errored Second counter is
invalid

Previous 24-hours ES counter :This


pm1001lhPerfTelecomLinePast24StatHistoryEsValuePor
1.3.6.1.4.1.20044.10.12.3.131.1.5 r OID gives the previous 24-hours
t1
Errored Second counter value

Previous 24-hours SES counter inv.


pm1001lhPerfTelecomLinePast24StatHistoryInvSesPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.131.1.6 r
1 24-hours severely Errored Second
counter is invalid

Previous 24-hours SES counter


pm1001lhPerfTelecomLinePast24StatHistorySesValueP :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.3.131.1.7 r
ort1 hours severely Errored Second
counter value

Previous 24-hours SEFS counter


pm1001lhPerfTelecomLinePast24StatHistoryInvSefsPort inv. :This OID indicates that the
1.3.6.1.4.1.20044.10.12.3.131.1.8 r
1 previous 24-hours severely Errored
Framing Second counter is invalid

Previous 24-hours SEFS counter


pm1001lhPerfTelecomLinePast24StatHistorySefsValueP :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.3.131.1.9 r
ort1 hours severely Errored Framing
Second counter value

Previous 24-hours UAS counter inv.


pm1001lhPerfTelecomLinePast24StatHistoryInvUasPort :This OID indicates that the previous
1.3.6.1.4.1.20044.10.12.3.131.1.10 r
1 24-hours UnAvailable Second
counter is invalid

Previous 24-hours UAS counter


pm1001lhPerfTelecomLinePast24StatHistoryUasValueP :This OID gives the previous 24-
1.3.6.1.4.1.20044.10.12.3.131.1.11 r
ort1 hours UnAvailable Second counter
value

1.3.6.1.4.1.20044.10.12.4 pm1001lhRmon
1.3.6.1.4.1.20044.10.12.4.1 pm1001lhRmonClient
List of
1.3.6.1.4.1.20044.10.12.4.1.16 pm1001lhMonupRmonByteCntTable n/a pm1001lhMonupRmonByteCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.16.1 pm1001lhMonupRmonByteCntEntry n/a
pm1001lhMonupRmonByteCnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.16.1.1 pm1001lhMonupRmonByteCntIndex r
pm1001lhMonupRmonByteCnt table

Bytes counter on Client input :This


counter is increased each time a
data byte is received on the client
1.3.6.1.4.1.20044.10.12.4.1.16.1.2 pm1001lhMonupRmonByteCntValuePortn r
port <Help> This counter gives the
number of bytes received on the
client port

Ekinops PM C1001HC(-ETR) documentation 103 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Input Bytes counter error :This OID


1.3.6.1.4.1.20044.10.12.4.1.16.1.3 pm1001lhMonupRmonByteCntErrorPortn r when set indicates the input Bytes
counter value is invalid on client port

Input Bytes counter overload :This


1.3.6.1.4.1.20044.10.12.4.1.16.1.4 pm1001lhMonupRmonByteCntOverloadPortn r OID when set indicates an input
Bytes counter overload on client port

List of
1.3.6.1.4.1.20044.10.12.4.1.24 pm1001lhMonupRmonCrcErrorCntTable n/a pm1001lhMonupRmonCrcErrorCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.24.1 pm1001lhMonupRmonCrcErrorCntEntry n/a pm1001lhMonupRmonCrcErrorCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.24.1.1 pm1001lhMonupRmonCrcErrorCntIndex r pm1001lhMonupRmonCrcErrorCnt
table

CRC Errors counter on Client input


:This counter is increased each time
a CRC error is detected on the client
1.3.6.1.4.1.20044.10.12.4.1.24.1.2 pm1001lhMonupRmonCrcErrorCntValuePortn r
port. <Help> This counter gives the
number of CRC Errors received on
the client port

Input CRC Errors counter error :This


OID when set indicates the input
1.3.6.1.4.1.20044.10.12.4.1.24.1.3 pm1001lhMonupRmonCrcErrorCntErrorPortn r
CRC Errors counter value is invalid
on client port

Input CRC Errors counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.24.1.4 pm1001lhMonupRmonCrcErrorCntOverloadPortn r
input CRC Errors counter overload
on client port

List of
1.3.6.1.4.1.20044.10.12.4.1.32 pm1001lhMonupRmonPacketsCntTable n/a pm1001lhMonupRmonPacketsCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.32.1 pm1001lhMonupRmonPacketsCntEntry n/a pm1001lhMonupRmonPacketsCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.32.1.1 pm1001lhMonupRmonPacketsCntIndex r pm1001lhMonupRmonPacketsCnt
table

Packets counter on Client input :This


counter is increased each time a
packet is received on the client port
1.3.6.1.4.1.20044.10.12.4.1.32.1.2 pm1001lhMonupRmonPacketsCntValuePortn r
<Help> This counter gives the
number of packets received on the
client port

Input Packets counter error :This


OID when set indicates the input
1.3.6.1.4.1.20044.10.12.4.1.32.1.3 pm1001lhMonupRmonPacketsCntErrorPortn r
Packets counter value is invalid on
client port

Input Packets counter overload :This


OID when set indicates an input
1.3.6.1.4.1.20044.10.12.4.1.32.1.4 pm1001lhMonupRmonPacketsCntOverloadPortn r
Packets counter overload on client
port

List of
1.3.6.1.4.1.20044.10.12.4.1.40 pm1001lhMonupRmonBroadcastCntTable n/a pm1001lhMonupRmonBroadcastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.40.1 pm1001lhMonupRmonBroadcastCntEntry n/a pm1001lhMonupRmonBroadcastCnt
table

Ekinops PM C1001HC(-ETR) documentation 104 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Index definition for the


1.3.6.1.4.1.20044.10.12.4.1.40.1.1 pm1001lhMonupRmonBroadcastCntIndex r pm1001lhMonupRmonBroadcastCnt
table

Broadcast counter on Client input


:This counter is increased each time
a broadcast packet is received on
1.3.6.1.4.1.20044.10.12.4.1.40.1.2 pm1001lhMonupRmonBroadcastCntValuePortn r
the client port. <Help> This counter
gives the number of Broadcast
packets received on the client port

Input Broadcast counter error :This


OID when set indicates the input
1.3.6.1.4.1.20044.10.12.4.1.40.1.3 pm1001lhMonupRmonBroadcastCntErrorPortn r
Broadcast counter value is invalid on
client port

Input Broadcast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.40.1.4 pm1001lhMonupRmonBroadcastCntOverloadPortn r
input Broadcast counter overload on
client port

List of
1.3.6.1.4.1.20044.10.12.4.1.48 pm1001lhMonupRmonMulticastCntTable n/a pm1001lhMonupRmonMulticastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.48.1 pm1001lhMonupRmonMulticastCntEntry n/a pm1001lhMonupRmonMulticastCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.48.1.1 pm1001lhMonupRmonMulticastCntIndex r pm1001lhMonupRmonMulticastCnt
table

Multicast counter on Client input


:This counter is increased each time
a Multicast packet is received on the
1.3.6.1.4.1.20044.10.12.4.1.48.1.2 pm1001lhMonupRmonMulticastCntValuePortn r
client port. <Help> This counter
gives the number of Multicast
packets received on the client port

Input Multicast counter error :This


OID when set indicates the input
1.3.6.1.4.1.20044.10.12.4.1.48.1.3 pm1001lhMonupRmonMulticastCntErrorPortn r
Multicast counter value is invalid on
client port

Input Multicast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.48.1.4 pm1001lhMonupRmonMulticastCntOverloadPortn r
input Multicast counter overload on
client port

List of
1.3.6.1.4.1.20044.10.12.4.1.56 pm1001lhMonupRmonTimerCntTable n/a pm1001lhMonupRmonTimerCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.56.1 pm1001lhMonupRmonTimerCntEntry n/a pm1001lhMonupRmonTimerCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.56.1.1 pm1001lhMonupRmonTimerCntIndex r pm1001lhMonupRmonTimerCnt
table
RMON Timer on client input :This is
the timing counter dedicated to the
1.3.6.1.4.1.20044.10.12.4.1.56.1.2 pm1001lhMonupRmonTimerCntValuePortn r
upstream RMON counters. It is
incremented every 125 us.

Input RMON Timer error :This OID


1.3.6.1.4.1.20044.10.12.4.1.56.1.3 pm1001lhMonupRmonTimerCntErrorPortn r when set indicates the input RMON
timer is invalid on client port
Input RMON Timer overload :This
1.3.6.1.4.1.20044.10.12.4.1.56.1.4 pm1001lhMonupRmonTimerCntOverloadPortn r OID when set indicates an input
RMON timer overload on client port

Ekinops PM C1001HC(-ETR) documentation 105 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

List of
1.3.6.1.4.1.20044.10.12.4.1.64 pm1001lhMonupRmonPauseFrameCntTable n/a pm1001lhMonupRmonPauseFrame
Cnt Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.64.1 pm1001lhMonupRmonPauseFrameCntEntry n/a pm1001lhMonupRmonPauseFrame
Cnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.64.1.1 pm1001lhMonupRmonPauseFrameCntIndex r pm1001lhMonupRmonPauseFrame
Cnt table

Pause counter on Client input :This


counter is increased each time a
1.3.6.1.4.1.20044.10.12.4.1.64.1.2 pm1001lhMonupRmonPauseFrameCntValuePortn r
Pause frame is received on the client
port

Input Pause counter error :This OID


1.3.6.1.4.1.20044.10.12.4.1.64.1.3 pm1001lhMonupRmonPauseFrameCntErrorPortn r when set indicates the input Pause
counter value is invalid on client port

Input Pause counter overload :This


OID when set indicates an input
1.3.6.1.4.1.20044.10.12.4.1.64.1.4 pm1001lhMonupRmonPauseFrameCntOverloadPortn r
Pause counter overload on client
port

List of
1.3.6.1.4.1.20044.10.12.4.1.72 pm1001lhMonupRmonDropFrameCntTable n/a pm1001lhMonupRmonDropFrameC
nt Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.72.1 pm1001lhMonupRmonDropFrameCntEntry n/a pm1001lhMonupRmonDropFrameC
nt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.72.1.1 pm1001lhMonupRmonDropFrameCntIndex r pm1001lhMonupRmonDropFrameC
nt table

Drop counter on Client input :This


counter is increased each time a
1.3.6.1.4.1.20044.10.12.4.1.72.1.2 pm1001lhMonupRmonDropFrameCntValuePortn r
Frame is dropped on the input client
port

Input Drop counter error :This OID


1.3.6.1.4.1.20044.10.12.4.1.72.1.3 pm1001lhMonupRmonDropFrameCntErrorPortn r when set indicates the input Drop
counter value is invalid on client port
Input Drop counter overload :This
1.3.6.1.4.1.20044.10.12.4.1.72.1.4 pm1001lhMonupRmonDropFrameCntOverloadPortn r OID when set indicates an input
Drop counter overload on client port
List of pm1001lhMonupRmonBitsCnt
1.3.6.1.4.1.20044.10.12.4.1.80 pm1001lhMonupRmonBitsCntTable n/a
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.80.1 pm1001lhMonupRmonBitsCntEntry n/a
pm1001lhMonupRmonBitsCnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.80.1.1 pm1001lhMonupRmonBitsCntIndex r
pm1001lhMonupRmonBitsCnt table
Bits counter on Client Input :This
1.3.6.1.4.1.20044.10.12.4.1.80.1.2 pm1001lhMonupRmonBitsCntValuePortn r counter is increased each time a bit
is received on the input client port
Input Bits counter error :This OID
1.3.6.1.4.1.20044.10.12.4.1.80.1.3 pm1001lhMonupRmonBitsCntErrorPortn r when set indicates the input Bits
counter value is invalid on client port
Input Bits counter overload :This OID
1.3.6.1.4.1.20044.10.12.4.1.80.1.4 pm1001lhMonupRmonBitsCntOverloadPortn r when set indicates an input Bits
counter overload on client port
List of
1.3.6.1.4.1.20044.10.12.4.1.88 pm1001lhMonupRmonUnicastCntTable n/a pm1001lhMonupRmonUnicastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.88.1 pm1001lhMonupRmonUnicastCntEntry n/a pm1001lhMonupRmonUnicastCnt
table

Ekinops PM C1001HC(-ETR) documentation 106 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Index definition for the


1.3.6.1.4.1.20044.10.12.4.1.88.1.1 pm1001lhMonupRmonUnicastCntIndex r pm1001lhMonupRmonUnicastCnt
table

Unicast counter on Client input :This


counter is increased each time a
Unicast packet is received on client
1.3.6.1.4.1.20044.10.12.4.1.88.1.2 pm1001lhMonupRmonUnicastCntValuePortn r
input <Help> This counter gives the
number of Unicast packets received
on the client input port

Input Unicast counter error :This OID


1.3.6.1.4.1.20044.10.12.4.1.88.1.3 pm1001lhMonupRmonUnicastCntErrorPortn r when set indicates the input Drop
counter value is invalid on client port
Input Unicast counter overload :This
1.3.6.1.4.1.20044.10.12.4.1.88.1.4 pm1001lhMonupRmonUnicastCntOverloadPortn r OID when set indicates an input
Drop counter overload on client port
List of
1.3.6.1.4.1.20044.10.12.4.1.96 pm1001lhMonupRmonNonUnicastCntTable n/a pm1001lhMonupRmonNonUnicastC
nt Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.96.1 pm1001lhMonupRmonNonUnicastCntEntry n/a pm1001lhMonupRmonNonUnicastC
nt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.96.1.1 pm1001lhMonupRmonNonUnicastCntIndex r pm1001lhMonupRmonNonUnicastC
nt table

Non Unicast counter on Client Input


:This counter is increased each time
a Non Unicast packet is received on
1.3.6.1.4.1.20044.10.12.4.1.96.1.2 pm1001lhMonupRmonNonUnicastCntValuePortn r client input <Help> This counter
gives the number of Non Unicast
packets received on the client input
port

Input Non Unicast counter error :This


1.3.6.1.4.1.20044.10.12.4.1.96.1.3 pm1001lhMonupRmonNonUnicastCntErrorPortn r OID when set indicates the input Bits
counter value is invalid on client port

Input Non Unicast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.96.1.4 pm1001lhMonupRmonNonUnicastCntOverloadPortn r
input Bits counter overload on client
port

List of
1.3.6.1.4.1.20044.10.12.4.1.112 pm1001lhMondwRmonByteCntTable n/a pm1001lhMondwRmonByteCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.112.1 pm1001lhMondwRmonByteCntEntry n/a
pm1001lhMondwRmonByteCnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.112.1.1 pm1001lhMondwRmonByteCntIndex r
pm1001lhMondwRmonByteCnt table

Bytes counter on Client output :This


counter is increased each time a
data byte is transmitted on the client
1.3.6.1.4.1.20044.10.12.4.1.112.1.2 pm1001lhMondwRmonByteCntValuePortn r
port. <Help> This counter gives the
number of bytes transmitted on the
client port

Output Bytes counter error :This OID


1.3.6.1.4.1.20044.10.12.4.1.112.1.3 pm1001lhMondwRmonByteCntErrorPortn r when set indicates the output Bytes
counter value is invalid on client port

Output Bytes counter overload :This


1.3.6.1.4.1.20044.10.12.4.1.112.1.4 pm1001lhMondwRmonByteCntOverloadPortn r OID when set indicates an output
Bytes counter overload on client port

Ekinops PM C1001HC(-ETR) documentation 107 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

List of
1.3.6.1.4.1.20044.10.12.4.1.120 pm1001lhMondwRmonCrcErrorCntTable n/a pm1001lhMondwRmonCrcErrorCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.120.1 pm1001lhMondwRmonCrcErrorCntEntry n/a pm1001lhMondwRmonCrcErrorCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.120.1.1 pm1001lhMondwRmonCrcErrorCntIndex r pm1001lhMondwRmonCrcErrorCnt
table

CRC Errors counter on Client output


:This counter is increased each time
a CRC error is detected on the
1.3.6.1.4.1.20044.10.12.4.1.120.1.2 pm1001lhMondwRmonCrcErrorCntValuePortn r
output client port <Help> This
counter gives the number of CRC
Errors transmitted on the client port

Output CRC Errors counter error


:This OID when set indicates the
1.3.6.1.4.1.20044.10.12.4.1.120.1.3 pm1001lhMondwRmonCrcErrorCntErrorPortn r
output CRC Errors counter value is
invalid on client port

Output CRC Errors counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.120.1.4 pm1001lhMondwRmonCrcErrorCntOverloadPortn r
output CRC Errors counter overload
on client port

List of
1.3.6.1.4.1.20044.10.12.4.1.128 pm1001lhMondwRmonPacketsCntTable n/a pm1001lhMondwRmonPacketsCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.128.1 pm1001lhMondwRmonPacketsCntEntry n/a pm1001lhMondwRmonPacketsCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.128.1.1 pm1001lhMondwRmonPacketsCntIndex r pm1001lhMondwRmonPacketsCnt
table

Packets counter on Client output


:This counter is increased each time
a packet is transmitted on the client
1.3.6.1.4.1.20044.10.12.4.1.128.1.2 pm1001lhMondwRmonPacketsCntValuePortn r
port. <Help> This counter gives the
number of packets transmitted on
the client port

Output Packets counter error :This


OID when set indicates the output
1.3.6.1.4.1.20044.10.12.4.1.128.1.3 pm1001lhMondwRmonPacketsCntErrorPortn r
Packets counter value is invalid on
client port

Output Packets counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.128.1.4 pm1001lhMondwRmonPacketsCntOverloadPortn r
output Packets counter overload on
client port

List of
1.3.6.1.4.1.20044.10.12.4.1.136 pm1001lhMondwRmonBroadcastCntTable n/a pm1001lhMondwRmonBroadcastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.136.1 pm1001lhMondwRmonBroadcastCntEntry n/a pm1001lhMondwRmonBroadcastCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.136.1.1 pm1001lhMondwRmonBroadcastCntIndex r pm1001lhMondwRmonBroadcastCnt
table

Ekinops PM C1001HC(-ETR) documentation 108 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

Broadcast counter on Client output


:This counter is increased each time
a broadcast packet is transmitted on
1.3.6.1.4.1.20044.10.12.4.1.136.1.2 pm1001lhMondwRmonBroadcastCntValuePortn r
the client port. <Help> This counter
gives the number of Broadcast
packets transmitted on the client port

Output Broadcast counter error :This


OID when set indicates the output
1.3.6.1.4.1.20044.10.12.4.1.136.1.3 pm1001lhMondwRmonBroadcastCntErrorPortn r
Broadcast counter value is invalid on
client port

Output Broadcast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.136.1.4 pm1001lhMondwRmonBroadcastCntOverloadPortn r
output Broadcast counter overload
on client port

List of
1.3.6.1.4.1.20044.10.12.4.1.144 pm1001lhMondwRmonMulticastCntTable n/a pm1001lhMondwRmonMulticastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.144.1 pm1001lhMondwRmonMulticastCntEntry n/a pm1001lhMondwRmonMulticastCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.144.1.1 pm1001lhMondwRmonMulticastCntIndex r pm1001lhMondwRmonMulticastCnt
table

Multicast counter on Client output


:This counter is increased each time
a Multicast packet is tra,smitted on
1.3.6.1.4.1.20044.10.12.4.1.144.1.2 pm1001lhMondwRmonMulticastCntValuePortn r
the client port. <Help> This counter
gives the number of Multicast
packets transmitted on the client port

Output Multicast counter error :This


OID when set indicates the output
1.3.6.1.4.1.20044.10.12.4.1.144.1.3 pm1001lhMondwRmonMulticastCntErrorPortn r
Multicast counter value is invalid on
client port

Output Multicast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.144.1.4 pm1001lhMondwRmonMulticastCntOverloadPortn r
output Multicast counter overload on
client port

List of
1.3.6.1.4.1.20044.10.12.4.1.152 pm1001lhMondwRmonPauseFrameCntTable n/a pm1001lhMondwRmonPauseFrame
Cnt Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.152.1 pm1001lhMondwRmonPauseFrameCntEntry n/a pm1001lhMondwRmonPauseFrame
Cnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.152.1.1 pm1001lhMondwRmonPauseFrameCntIndex r pm1001lhMondwRmonPauseFrame
Cnt table

Pause counter on Client output :This


counter is increased each time a
1.3.6.1.4.1.20044.10.12.4.1.152.1.2 pm1001lhMondwRmonPauseFrameCntValuePortn r
Pause frame is generated by the PM
on the client port

Output Pause counter error :This


OID when set indicates the output
1.3.6.1.4.1.20044.10.12.4.1.152.1.3 pm1001lhMondwRmonPauseFrameCntErrorPortn r
Pause counter value is invalid on
client port

Output Pause counter overload :This


OID when set indicates an output
1.3.6.1.4.1.20044.10.12.4.1.152.1.4 pm1001lhMondwRmonPauseFrameCntOverloadPortn r
Pause counter overload on client
port

Ekinops PM C1001HC(-ETR) documentation 109 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

List of
1.3.6.1.4.1.20044.10.12.4.1.160 pm1001lhMondwRmonTimerCntTable n/a pm1001lhMondwRmonTimerCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.160.1 pm1001lhMondwRmonTimerCntEntry n/a pm1001lhMondwRmonTimerCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.160.1.1 pm1001lhMondwRmonTimerCntIndex r pm1001lhMondwRmonTimerCnt
table

RMON Timer on client output :This is


the timing counter dedicated to the
1.3.6.1.4.1.20044.10.12.4.1.160.1.2 pm1001lhMondwRmonTimerCntValuePortn r
downstream RMON counters. It is
incremented every 125 us.

Output RMON Timer error :This OID


1.3.6.1.4.1.20044.10.12.4.1.160.1.3 pm1001lhMondwRmonTimerCntErrorPortn r when set indicates the output RMON
timer is invalid on client port
Output RMON Timer overload :This
1.3.6.1.4.1.20044.10.12.4.1.160.1.4 pm1001lhMondwRmonTimerCntOverloadPortn r OID when set indicates an output
RMON timer overload on client port
List of
1.3.6.1.4.1.20044.10.12.4.1.168 pm1001lhMondwRmonBitsCntTable n/a pm1001lhMondwRmonBitsCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.168.1 pm1001lhMondwRmonBitsCntEntry n/a
pm1001lhMondwRmonBitsCnt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.168.1.1 pm1001lhMondwRmonBitsCntIndex r
pm1001lhMondwRmonBitsCnt table
Bits counter on Client Output :This
1.3.6.1.4.1.20044.10.12.4.1.168.1.2 pm1001lhMondwRmonBitsCntValuePortn r counter is increased each time a bit
is received on the Output client port
Output Bits counter error :This OID
1.3.6.1.4.1.20044.10.12.4.1.168.1.3 pm1001lhMondwRmonBitsCntErrorPortn r when set indicates the output Bits
counter value is invalid on client port
Output Bits counter overload :This
1.3.6.1.4.1.20044.10.12.4.1.168.1.4 pm1001lhMondwRmonBitsCntOverloadPortn r OID when set indicates an output
Bits counter overload on client port
List of
1.3.6.1.4.1.20044.10.12.4.1.176 pm1001lhMondwRmonUnicastCntTable n/a pm1001lhMondwRmonUnicastCnt
Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.176.1 pm1001lhMondwRmonUnicastCntEntry n/a pm1001lhMondwRmonUnicastCnt
table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.176.1.1 pm1001lhMondwRmonUnicastCntIndex r pm1001lhMondwRmonUnicastCnt
table

Unicast counter on Client output


:This counter is increased each time
a Unicast packet is transmitted on
1.3.6.1.4.1.20044.10.12.4.1.176.1.2 pm1001lhMondwRmonUnicastCntValuePortn r
client port <Help> This counter
gives the number of Unicast packets
transmitted on the client output port

Output Unicast counter error :This


1.3.6.1.4.1.20044.10.12.4.1.176.1.3 pm1001lhMondwRmonUnicastCntErrorPortn r OID when set indicates the output
RMON timer is invalid on client port

Output Unicast counter overload


:This OID when set indicates an
1.3.6.1.4.1.20044.10.12.4.1.176.1.4 pm1001lhMondwRmonUnicastCntOverloadPortn r
output RMON timer overload on
client port

Ekinops PM C1001HC(-ETR) documentation 110 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.
Appendix C : PM C1001HC MIB description

List of
1.3.6.1.4.1.20044.10.12.4.1.184 pm1001lhMondwRmonNonUnicastCntTable n/a pm1001lhMondwRmonNonUnicastC
nt Article
Row definition for the
1.3.6.1.4.1.20044.10.12.4.1.184.1 pm1001lhMondwRmonNonUnicastCntEntry n/a pm1001lhMondwRmonNonUnicastC
nt table
Index definition for the
1.3.6.1.4.1.20044.10.12.4.1.184.1.1 pm1001lhMondwRmonNonUnicastCntIndex r pm1001lhMondwRmonNonUnicastC
nt table

Non Unicast counter on Client output


:This counter is increased each time
a Non Unicast packet is transmitted
1.3.6.1.4.1.20044.10.12.4.1.184.1.2 pm1001lhMondwRmonNonUnicastCntValuePortn r on client port <Help> This counter
gives the number of Non Unicast
packets transmitted on the client
output port

Output Non Unicast counter error


:This OID when set indicates the
1.3.6.1.4.1.20044.10.12.4.1.184.1.3 pm1001lhMondwRmonNonUnicastCntErrorPortn r
output Bits counter value is invalid
on client port

Output Non Unicast counter


overload :This OID when set
1.3.6.1.4.1.20044.10.12.4.1.184.1.4 pm1001lhMondwRmonNonUnicastCntOverloadPortn r
indicates an output Bits counter
overload on client port

1.3.6.1.4.1.20044.10.12.4.2 pm1001lhRmonLine
1.3.6.1.4.1.20044.10.12.4.3 pm1001lhRmonOther
RMON Counters Reset:This OID
1.3.6.1.4.1.20044.10.12.4.3.359 pm1001lhMonCountersReset r/w resets and restarts all the RMON
counters
RMON Counters stop:This OID
1.3.6.1.4.1.20044.10.12.4.3.360 pm1001lhMonCountersStop r/w
stops all the RMON counters
1.3.6.1.4.1.20044.10.11.30 pm1001lhLineTrapNotUrgentGoesOn n/a Not urgent Line default is activated
1.3.6.1.4.1.20044.10.11.31 pm1001lhLineTrapNotUrgentGoesOff n/a Not urgent Line default disappeared
1.3.6.1.4.1.20044.10.11.32 pm1001lhLineTrapUrgentGoesOn n/a Urgent Line default is activated
1.3.6.1.4.1.20044.10.11.33 pm1001lhLineTrapUrgentGoesOff n/a Urgent Line default disappeared
1.3.6.1.4.1.20044.10.11.34 pm1001lhLineTrapCritGoesOn n/a Critical Line default is activated
1.3.6.1.4.1.20044.10.11.35 pm1001lhLineTrapCritGoesOff n/a Critical Line default disappeared
1.3.6.1.4.1.20044.10.11.40 pm1001lhClientTrapNotUrgentGoesOn n/a Not urgent client default is activated

1.3.6.1.4.1.20044.10.11.41 pm1001lhClientTrapNotUrgentGoesOff n/a Not urgent client default disappeared

1.3.6.1.4.1.20044.10.11.42 pm1001lhClientTrapUrgentGoesOn n/a Urgent client default is activated


1.3.6.1.4.1.20044.10.11.43 pm1001lhClientTrapUrgentGoesOff n/a Urgent client default disappeared
1.3.6.1.4.1.20044.10.11.44 pm1001lhClientTrapCritGoesOn n/a Critical client default is activated
1.3.6.1.4.1.20044.10.11.45 pm1001lhClientTrapCritGoesOff n/a Critical client default disappeared
Urgent power supply default is
1.3.6.1.4.1.20044.10.11.50 pm1001lhPowerTrapUrgentGoesOn n/a
activated
Urgent power supply default
1.3.6.1.4.1.20044.10.11.51 pm1001lhPowerTrapUrgentGoesOff n/a
disappeared

Ekinops PM C1001HC(-ETR) documentation 111 /


Date: August 16th 2016 Rev 2.11 4DP 1140 0000 UMEN 111
Duplication or communication of this document is prohibited without prior written authorisation from EKINOPS
Subject to change without prior notice.