You are on page 1of 36

A-7139780

09 | 02.2013 | | Printed in Germany

Automatic entrance systems

GS - 100

GB Automatic sliding door


Installation Manual
Translation of the original Instructions
Installation Manual

GS - 100
Automatic sliding door

Table of contents
1. Tools, screws, and nuts................................................................ Page 4

2. General safety instructions and definitions............................... Page 6


2.1 Explanation of symbols.................................................................................................Page 6
2.2 Instructions.....................................................................................................................Page 6
2.2.1 Emergency escape doors .............................................................................................Page 6

3. Technical Data.............................................................................. Page 7


3.1 Ambient conditions........................................................................................................Page 7

4. Installation................................................................................... Page 8
4.1 Special safety instructions............................................................................................Page 8
4.2 Electrical connections...................................................................................................Page 8
4.3 Explanation of the terms and abbreviations:.............................................................Page 8
4.4 Installation preparation.................................................................................................Page 8
4.5 Applicable Documents..................................................................................................Page 8
4.6 Position of the single components..............................................................................Page 9

5. Mounting..................................................................................... Page 10
5.1 Mounting height.............................................................................................................Page 10
5.2 Track profile.....................................................................................................................Page 11
5.3 Wall connection profile.................................................................................................Page 12
5.4 Drilling holes for light barrier wiring to the track profile........................................Page 12
5.5 Wiring of the light barriers...........................................................................................Page 13
5.6 Leaves...............................................................................................................................Page 14
5.7 Fixing the floor guide, height and depth adjustment of the leaves.......................Page 16
5.8 Drive unit.........................................................................................................................Page 18
5.9 Pulley................................................................................................................................Page 19
5.10 Belt....................................................................................................................................Page 20
5.11 End buffer........................................................................................................................Page 23
5.12 Feeder clamp...................................................................................................................Page 24
5.13 Battery pack (option).....................................................................................................Page 25
5.14 Cover support (option)..................................................................................................Page 26
5.15 Lock (option)...................................................................................................................Page 27
5.16 Cover (option).................................................................................................................Page 29
5.17 Infrared field....................................................................................................................Page 31
5.18 Single leaf door installation..........................................................................................Page 32

6. Guidelines and test marks........................................................... Page 34


6.1 Certificates......................................................................................................................Page 34

2 GB 02.2013 | A-7139780 | Printed in Germany


3
Installation Manual

GS - 100
Automatic sliding door

1. Tools, screws, and nuts

Water level

Drilling machine

Cross head screwdriver medium sized

Tape measure

Allen key 2,5; 3; 4; 5;

HSS drill bits

Stone drill bits

Combination spanner for hexagon head bolts


SW10; SW13; SW17; SW19

4 GB 02.2013 | A-7139780 | Printed in Germany


Self-tapping screw zinced Hexagon nut zinced
A DIN 7981-4,2x131 F DIN 934-M5

Hexagon socket head capscrew


B zinced DIN 912-M4x12
Hexagon nut zinced
G DIN 934-M6

Hexagon socket head capscrew


C zinced DIN 912-M5x10

Hexagon socket head capscrew


Washer zinced
D zinced DIN 912-M6x10
H DIN 125-5,3

Hexagon bolt zinced


E DIN 933-M8x14
Washer zinced
I DIN 125-6,4

Washer zinced
K DIN 125-8,4

5
Installation Manual

GS - 100
Automatic sliding door

2. General safety instructions and definitions

2.1 Explanation of symbols


These safety instructions are indicated with special symbols:

Caution: Danger of injury! This symbol points to the possibility of endangering people.

Attention: General danger! This symbol indicates an operation that could cause a damage to
the sliding door or the operating controls.

Caution: Direct or indirect danger for life and health caused by electrical energy. Special work
only for electricians.

Attention: Special indication to regulation on emergency escape doors.

Note: This symbol indicates important instructions..

This symbol calls on for operation.

2.2 Instructions
Please observe all national guidelines and standards on automatic sliding doors.

The intended use includes the operating and commissioning conditions instructed by the
manufacturer.

Commissioning, maintenance and servicing should only be carried out by specialised personnel that
has been authorised by the manufacturer or by trained people who are aware of any possible danger
that may occur.
The operating service and maintenance conditions specified by the manufacturer are to be observed.

The manufacturer is exempted from any liability for damages caused by unauthorised alterations of
the system.
After professional installation the sliding doors are only to be used for sliding operations. Any other
use is not allowed and excludes the liability of the manufacturer.

The manufacturer has to be informed if constructional alterations (floor, conditions for air current
etc.) at the sliding door area influencing the function of the construction.

2.2.1 Emergency escape doors

Attention! For emergency escape doors respect national laws and normatives!

Please observe all safety instructions and warnings.

6 GB 02.2013 | A-7139780 | Printed in Germany


3. Technical Data

Rated voltage ~230 V AC; ±10% 50 Hz

Rated current 3A

Control voltage 24 V DC

Opening speed max. 0,9 m/s

Closing speed max. 0,7 m/s

Hold open time max. 99 seconds

Maximum opening width single leaf 700-1800 mm

Maximum opening width double leaf 900-2800 mm

Maximum weight door leaf 100 kg/leaf

Other dimensions on request

Protection class class I

Environmental temperature -15° - + 50° Celsius

3.1 Ambient conditions


Dry rooms: Ingress Protection Rating IP 20

7
Installation Manual

GS - 100
Automatic sliding door

4. Installation

4.1 Special safety instructions


Before starting installation, please read all the installation instructions.

4.2 Electrical connections


For mounting the drive there must be earth contact connection on building site.

If there is no earth contact connection, the connection must be secured in accordance with national
directives against accidental switching on. The installation has only be carried out by specialised
personnel.

During working on the construction make sure that the power supply is disconnected.

It must be protected against mistaken switch-on. The cut-off of the construction must be inspected.

If there is any damage at the main connection the power plug must be disconnected. Specialists
must change the main connection.

Optional the construction is equipped with a lead gel battery. Please note that the battery is not
shorted.

4.3 Explanation of the terms and abbreviations:


DL Door Leaf (FF) PH Passage height (LDH) FFL Finish floor level (OKFF)

Devices which do not belong to the


h Height l Length option basic version

Height of leaf
DLH lmin Minimum length Deburring

hMont Mounting height lR Whole length of the belt


OW Opening width (LDB) VE Packaging unit

All measures are in millimetre (mm).

4.4 Installation preparation


ZZ
Please observe the national regulations for automatic doors and electric security carefully.

ZZ
Check the structure for:

„„
odd corners „„
sufficient strength of the subsoil

„„
evenness of the installation surface and the „„
manner of fixation.
floor

ZZ
Choose type of fitting in accordance with the general technical regulations (e.g. for aluminium
profiles, concrete, timber).

ZZ
Check whether the available drive and door components comply with the installation
requirements on site.

ZZ
Check the available components for damage.

ZZ
Determine the correct mounting height for the installation dimensions and the centre of the
door (see page 10).

4.5 Applicable Documents


For this door construction also see
Electrical Documentation, Wiring diagrams and Commissioning GS-100 A-7151390.

8 GB 02.2013 | A-7139780 | Printed in Germany


4.6
Drive unit GS-100

Carriage
Position of the single components

Carriage
Cover support
(option)

Endbuffer

Battery pack
Feeder clamp (option)
Belt connection
Lock Pulley
(option) Endbuffer

Cover fixing
(option)

9
Installation Manual

GS - 100
Automatic sliding door

5. Mounting

5.1 Mounting height

202

130
28
95

40

12

Mounting height:
hMount= DLH + 7mm + 28mm
Mounting height hMount

DLH
PH

6-8

FFL
60
7

10 GB 02.2013 | A-7139780 | Printed in Germany


5.2 Track profile

1.1 ... 2

1.1. Length of slide track profile


double leaf installations: lmin= 2 x OW + 100vw

XX
Different installation
for single leaf doors;
see "Single leaf door installation".
Ø8,5
50

≤400

≤400

1.2.

Type of fixing in accordance to the wall

XX
Clean slide track profile before continuing.

11
Installation Manual

GS - 100
Automatic sliding door

5.3 Wall connection profile

Only with GU Automatic


1.1
G30 profile system.

Connection profile A-7027650

1.1.

ZZ
Type of fixing in accordance to the wall

5.4 Drilling holes for light barrier wiring to the track profile

1 XX
Alternative infrared field q.v. p. 34.

1.1
Only with GU Automatic
light barrier.
1.1

12 GB 02.2013 | A-7139780 | Printed in Germany


1.1.

Bottom view

10,5

Ø9
10,5

ZZ
Remove any drilling chips before continuing.

ZZ
Additionally use the protective sleeve for the
light-barrier cables.

5.5 Wiring of the light barriers

Transmitter
5.1 Receiver
5.1
*
1000*
200

*
1000

* 200

* based on national standards

13
Installation Manual

GS - 100
Automatic sliding door

5.6 Leaves

1.1 ... 2

1.1 ... 2
1.1 ... 2

1.2. Positioning and fixing the carriage onto the leaf

46 46

1.3. 2
1 1
1. Loosen the screws.

2. Push down upper roll.

ZZ
Height adjustment of the carrige in middle position

14 GB 02.2013 | A-7139780 | Printed in Germany


1.4. Adjustment of the upper roll

1.4.1 1.4.2
1. Adjust the upper roll.

2. Fasten the screws.

2
2

1.4.3
1

15
Installation Manual

GS - 100
Automatic sliding door

5.7 Fixing the floor guide, height and depth adjustment of the leaves

1.2.1 ... 2
1.2.1 ... 2
1.2.1 ... 2

1.1

1.1

1.1.

ZZ
Type of fixing in accordance to the surface.

Only with GU Automatic G30 profile system.

16 GB 02.2013 | A-7139780 | Printed in Germany


1.2. Height adjustment:
1. Loosen the screws.

2. Adjust the hight.


2 3. Fasten the screws.

3
1
3
1

1.3. Depth adjustment

ZZ
Align the carriage parallel to the track profile.

1. Loosen the screws.

1 3 2. Adjust the depth.

3. Fasten the screws.

1 3
2

17
Installation Manual

GS - 100
Automatic sliding door

5.8 Drive unit

1.1 ... 2

1.1.

1.2.
255
200 Opening width

ZZ
Different installation
for single leaf doors;
see “Single leaf door installation”.

18 GB 02.2013 | A-7139780 | Printed in Germany


5.9 Pulley

1.1 ... 3

1.1. 1.2.
ZZ
Remove the tension at the pulley

1.3.
Opening width 180

ZZ
Different installation
for single leaf doors;
see “Single leaf door installation”.

19
Installation Manual

GS - 100
Automatic sliding door

5.10 Belt

1 Belt calculation

Length of the belt lbelt:

Double leaf: lbelt = 2 x OW + 950 ZZ


Different calculation
for single leaf doors;
see “Single leaf door installation”.

2 Mounting of the belt

2.1.

2.2.

20 GB 02.2013 | A-7139780 | Printed in Germany


3 Clamping of the belt

3.1.

Right leaf, left carriage

ZZ
Different installation
for single leaf doors;
see “Single leaf door
installation”.

3.2.

Right leaf, left carriage

3.3.

Centric alignment

21
Installation Manual

GS - 100
Automatic sliding door

3.4.

Left leaf, right carriage

ZZ
Different installation
for single leaf doors;
see “Single leaf door
installation”.

3.5.

4 Tightening of the belt

4.1. 4.2.

2
1
3

22 GB 02.2013 | A-7139780 | Printed in Germany


5.11 End buffer

1.1 ... 3

1.1 ... 3

1.1. 1.2.

OW

1.3. 5

23
Installation Manual

GS - 100
Automatic sliding door

5.12 Feeder clamp

1.1 ... 2

1.1.

1.2. 45

24 GB 02.2013 | A-7139780 | Printed in Germany


5.13 Battery pack (option)

1
1.1 ... 2

1.1.

1.2. max. 70

25
Installation Manual

GS - 100
Automatic sliding door

5.14 Cover support (option)

1.1 ... 2

1.1 ... 2

1.1.

1.2. approx.
ca. 50-100 approx.
ca. 50-100

26 GB 02.2013 | A-7139780 | Printed in Germany


5.15 Lock (option)

1.1 ... 4

1.1.

27
Installation Manual

GS - 100
Automatic sliding door

1.2.
Right leaf,
right carriage

Latch

ZZ
Different installation
for single leaf doors;
see “Single leaf door
installation”.

1.3. Horizontal positioning of lock 1

2
Lock

1.4.

28 GB 02.2013 | A-7139780 | Printed in Germany


5.16 Cover (option)

1.2 ... 6 1.1

1.2 ... 6

1.1.
ZZ
Measure the position of the lock pin.

ZZ
Drill the hole with Ø 10 mm.

1.2.

Cover end cap

29
Installation Manual

GS - 100
Automatic sliding door

1.3. Earth contact connection

1.4. Mounting the cover 1.5.

1.6.

30 GB 02.2013 | A-7139780 | Printed in Germany


5.17 Infrared field

Alternative, depending on specifications of the construction on building site

ZZ
Mount the safety devices in accordance to the installation instructions of the
manufacturer.

ZZ
Deburr the drill holes.

ZZ
Remove any drilling chips before continuing.

50 50 Maximal distance

31
Installation Manual

GS - 100
Automatic sliding door

5.18 Single leaf door installation

Left-hand opening Right-hand opening

Slide track profile: Slide track profile:

lmin = 2 x OW + 100 lmin = 2 x OW + 100

Length of the belt: Length of the belt:

lR = 2 x OW + 700 lR = 2 x OW + 700

32 GB 02.2013 | A-7139780 | Printed in Germany


Left-hand opening Belt connection Left-hand opening, right carriage

OW + 365

OW + 275

OW - 65

Lock (option) Main closure edge

Right-hand opening Belt connection Right-hand opening, right carriage

OW - 300 OW + 275
100

Lock (option)
Main closure edge

33
Installation Manual

GS - 100
Automatic sliding door

6. Guidelines and test marks

The product described conforms to the regulations according to the following European guidelines:

2006/95/EC Low Voltage Directive.


Directive of the European Parliament and of the Council of 12 December 2006 on the harmonisation
of the laws of Member States with relating to electrical equipment designed for use within certain
voltage limits.

2004/108/EC EMC-Directive
Directive of the European Parliament and of the Council of 15 December 2004 on the approximation
of the laws of the Member States relating to electromagnetic compatibility and repealing Directive
89/336/EEC.

GU Automatic manufactured and commissioned the sliding door according to the guidelines.
Subsequent changes and alterations of the system should only be carried out by specialist personnel
with authorization of GU Automatic.

As a member in a German Association of Door Automation („Fachverband Türautomation“) we offer


Fachverband
competent consultation and highest quality.
Türautomation

6.1 Certificates
The certificate is renewed every year and available on GU Automatic homepage.

34 GB 02.2013 | A-7139780 | Printed in Germany


Blank due to typography

35
Editor:
GU Automatic GmbH
Stahlstraße 8
D-33378 Rheda-Wiedenbrück
Tel. + 49 (0) 5242924-0
Fax + 49 (0) 5242924-100

www.g-u.com
Errors and omissions reserved. Subject to technical modifications.