5 Port Solenoid Valve New

Plug-in Type
Thanks to the flow increase, valve size can be reduced!
Saves energy and space .
SY3000 SY5000 SY7000
10 mm 15 mm
18 mm

ø2, ø3.2,
ø4, ø6, ø8
1
fittings are connectable.

1: Type M10/M11 manifold

At 300 mm/s ø4, ø6, ø8


fittings are connectable.
ø32
Current At 300 mm/s
Valve ø6, ø8, ø10, ø12
size fittings are connectable.
ø50 DOWN ø50
Current
Possible to drive cylinders At 300 mm/s
Valve

2
Up to ø 50
(ø80 at 100 mm/s)
ø63
size
DOWN
Current
ø63
Possible to drive cylinders

2

Page
g 32
Up to ø63 ø80
(ø125 at 100 mm/s)
Plug-in Sub-plate newly added!
SY3000/5000
Possible to drive cylinders

2
Up to ø80
(ø160 at 100 mm/s)

2: Values based on comparison with the
current SMC model. For details, refer to
page 11.

Power consumption

: Refer to page 2.

0.1 w (With power saving circuit)

mVacuum Release Valve with Restrictor mDual port EX600 EtherNet/IP™ product
0.35 w (Standard)

mEX500 Gateway Decentralized System 2 Rubber seal (Service life: 70 million cycles)
New mSUP Stop Valve Spacer (With Residual Pressure Release Valve) Metal seal (Service life: 200 million cycles)
mWith Residual Pressure Release Valve (SY7000)
: According to SMC life test conditions

Series SY3000/5000/7000
CAT.ES11-103D
5 Port Solenoid Valve
Plug-in Metal Base [IP40]
Side ported From page 45 Bottom ported From page 45 Top ported From page 65

Plug-in Connector Connecting Base [IP67


1]

1: Refer to page 93 for details on IP67.

Manifold
Side ported From page 97 Bottom ported From page 97 Top ported From page 109

Plug-in Compatible sub-plate type ) Connector


(Only SY3000/5000)
type manifold Plug-in

mIP67 enclosure in standard specifications


mM12 waterproof connector type ensuring
easy attaching/detaching and wiring
mApplicable to the side, top and bottom <Enlarged view
ported. (4A, 2B port) of the connector>
Connector type manifold 32 outputs
Wiring
D-sub Connector Flat Ribbon Cable PC Wiring Terminal Block Box
Lead Wire Circular Connector Serial Transmission
Serial Transmission Variations
Integrated-type (for input/output) Integrated-type
Gateway-type serial transmission system serial transmission (for input/output) serial Integrated-type (for output) serial transmission system
system (Fieldbus system) transmission system
Series EX510 EX500 EX600 EX250 EX260 EX126 EX120

Applicable protocol

DeviceNetTM
PROFIBUS DP
CC-Link
EtherNet/IPTM
EtherCAT®
PROFINET
CANopen
AS-Interface
OMRON CompoBus/S
CompoNetTM
1
Series SY3000/5000/7000
Power Saving
[Electrical power waveform with power saving circuit] Power consumption is
Power Consumption Applied voltage reduced by power
24 V
saving circuit.
0V Power consumption is decreased

0.1 w 0.35 w
by approx. 1/3 by reducing the
Standard wattage required to hold the
0.35 (0.9) W
With power valve in an energized state.
saving circuit (Effective energizing time is over
0.1 (0.4) W 67 ms at 24 VDC.) Refer to the
With power saving circuit Standard
0W electrical power waveform as
67 ms (40 ms) shown on the left.

The value in ( ) are for the quick

Space Saving / Improved Operability response and high pressure types.

Wiring, piping and operation are integrated on one side. 4-position dual 3-port valve available
Multiple layer type is available as an From page 250 (Only rubber seal type)
option. This saves space in Piping s4WO PORTVALVESBUILTINTOONEBODY
the lateral direction.
Wiring Can be operated from the top.

SUP stop valve spacer


with residual pressure
release valve
Individual SUP/EXH
spacer

A side
spool valve B side
Bottom ported is prepared. Space saving spool valve
Top or bottom ported reduces
the footprint.
s PORTVALVESONTHE!AND"SIDESCANOPERATEINDEPENDENTLY
s7HENUSEDASA PORTVALVE ONLYHALFTHENUMBEROFSTATIONS
is required.
s#ANALSOBEUSEDASA POSITION  PORTVALVE
s POSITIONDUAL PORTVALVEWITHBACKPRESSURECHECKVALVEIS
available.
s#OMBINATIONEXAMPLES
Series A side B side
Panel fitting SY:A 03 0 N.C. valve N.C. valve
Installation SY:B 03 0 N.O. valve N.O. valve
SY:C 03 0 N.C. valve N.O. valve

Manifold overall length


Different sizes (SY3000/5000 or SY5000/7000) can be mixed! From page 213
Possible to reduce installation space, the number of serial units and wirings. Approx. 29 %
reduction
For serial transmission SY5000 manifold SY3000 manifold Mixed manifold
EX260 SY5000 3 stations SY3000 4 stations SY5000 3 stations SY3000 4 stations

BA BA BA B A B A B A B A B A B A B A B A B A B A B A

Installation 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A

space
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

12 B 12 B 12 B 12 B 12 B 12 B

136.7 mm 124.7 mm 186.7 mm

2 sets 1 set
Number of
serial units

2
5 Port Solenoid Valve
Improved Safety
Back Pressure Check Valve
This prevents actuator and air operated valve malfunctions caused by the exhaust from other valves.
1
Built-in valve type Back pressure check valve Retrofit or pre-installed type
(Check seal) If the product is affected by back pressure after
(A) (B) installation, the back pressure check
4 2 valve assembly can be added. Page 256

5 1 3
5 4 1 2 3 (EA) (P) (EB)
(EA)(A) (P) (B) (EB)


1: For back pressure check valve precautions,
refer to the Specific Product Precautions on page 267. Back pressure check
valve assembly

With residual pressure release valve (SY5000/7000) Page 23 IP67 compliant


Indicator
For residual pressure release of [When 1(P) port is pressurized] [When 1(P) port is not pressurized]
the 3-position closed center valve When P port is not pressurized
EXH. EXH.
· The pressure of the 4 (A) and 2 (B) ports is al-
EXH. EXH.
so exhausted automatically at the same when When P port is pressurized
the pressure of the 1 (P) port is exhausted. 4 2 4 2
· The pressure can be visualized using the indicator (red).
· Since this valve is not a spacer type, the flow rate is 5 3 5 3
1 1
equivalent to that of the normal closed center valve.

FREE

LOCK
Lever Type SUP Stop Valve Spacer (With residual
ual pressure release valve)) Page 251
Lever type is added to
manual override button!

Solenoid valves can be


replaced individually Easy to visually check
without shutting off the
main pressure!
1

2 action Push
STEP 1 No tools are
required.
STEP 2 Locked
Turn

Air for solenoid valves can be shut off individually! Solenoid valves can be replaced individually!
The operation of an n The solenoid valves
es can
actuator can be be replaced individually
dually
checked by shutting g off
off he
without stopping the
oid
the air for the solenoid equipment during
valves on the base maintenance.
he
individually, while the <Application example>
main air is being Air operated valves,
rial
supplied during a trial such as sanitary valve
operation. and automatic valve
control


1: This product is only for internal pilot specifications, as the external pilot air cannot
ca be shut off.
3
Series SY3000/5000/7000
Improved Safety
Slotted Type Slotted Type
SUP Stop Valve Spacer (With residual pressure release valve) Page 251 Double Check Spacer (With residual pressure release valve) Page 251
Air supply to each valve can be stopped individually. The valve and cylinder Long time of intermediate stop and position holding are possible.
can be replaced without stopping other devices and equipment.
Button for manual release [Intermediate stop] [Drop prevention]
Button for manual release
of residual pressure Double check spacer assembly Double check spacer assembly
of residual pressure
2-position single valve To exhaust residual pressure
To exhaust residual pressure on cylinder side.
on cylinder side. 4(A)
2(B)

SUP stop valve


spacer assembly

4(A) 2(B) 4(A) 2(B)


5(EA) 5(EA) 5(EA)
1(P) 1(P)
1(P) 3(EB) 3(EB)
3(EB)

2-position single valve example Exhaust center 2-position single/double

With slide locking manual override


ON/OFF operation and locking can be performed with the manual slide. ON

ON/B side OFF

Yellow Blue OFF/A side


B side A side

ON/OFF state can be checked at a glance.

With safety slide locking manual override


SY3000/5000/7000-X13 Page 31 SY7000-X13

Double action manual override prevents incorrect operation!


SY5000-X13
SY3000-X13
#Double action operation
The slide manual overrides cannot be turned ON Operates the safety slide The slide manual overrides
Before operation Operation 1 Operation 2
with the safety slide cover. (OFF status: Locked) cover upward. (Unlocked) can be operated.
Safety slide cover Slide manual overrides
<OFF>

<ON>

<Vertical sliding> <Horizontal sliding>



: The safety slide cover cannot be locked when the slide manual override is turned ON.
#Visual check
Red lines in three directions can be Safety slide covers can be checked from their raised and
checked whether the safety slide lowered positions.
cover is unlocked (FREE). Safety slide cover

Valve state
Unlocked (raised/lowered)
Red lines

Locked
4
5 Port Solenoid Valve
Piping Options
To mount the piping on top
Port block assembly One-touch fitting
for A, B port

Thread piping
Body cover assembly

Cover assembly

Port block assembly


for P, E port

Refer to page 271 for how to change piping types.

To mount the piping on the side Mixed mounting of top ported and
side ported is possible.

Top ported

Replace the fitting and


the port plug only.

Side ported

It is possible to detect the output of 4(A) and


2(B) port with a pressure switch by mounting the Pressure switch
top ported valve onto the side ported or bottom
ported manifold.
(Pressure switch etc., needs to be ordered
separately.)

5
Series SY3000/5000/7000
Variation
New Only for External Pilot Vacuum Release Valve with Restrictor Series SY 35 A:R Page 25

Vacuum suction and release can be controlled with a single valve!

Restrictor
PE s Flow rate adjustment of release air
Pilot EXH port s Prevents workpiece blow-off.
<Manual operation>

2(B)
Vacuum pad port
X
External pilot port 1(P)
Release pressure port
3/5(E)
Vacuum pressure port

Can be mounted on the same manifold with Mountable manifolds


the standard valve. 3
Connector connecting base SS5Y5 -10/11/12 type manifold

: When the individual EXH spacer is used. Metal base
3
SS5Y5 -50/52 type manifold

Example D side U side

(Not use) 5(EA) 5(EA)


Release pressure port 1(P) 1(P)
Vacuum pressure port 3(EB) 3(EB)
X X
(SY3A0R) (SY3A0R) (SY3A0R) (SY3A0R) (SY3A0R)
SOL.b

SOL.b

SOL.b

SOL.b

SOL.b
SOL.a

SOL.a

SOL.a

SOL.a

SOL.a

2(B) 2(B) 2(B) 2(B) 2(B)


Vacuum pad port Vacuum pad port Vacuum pad port Vacuum pad port Vacuum pad port

6
5 Port Solenoid Valve
Variations
Wiring A, B
Common
Valve Connection specification
Series Serial transmission

Terminal block box

Circular connector

Negative common
Positive common
Flat ribbon cable
D-sub connector
C2

EX500 (128 points)


M12 connector

EX500 (64 points)


PC wiring

Lead wire
Variations
M5 1/8 1/4 3/8

Straight piping
EX510

EX600
EX250
EX260
EX126
EX120
5 ports

SY3:03 : —
Sub-plate


SY5:03 : — — — — — —
From
Plug-in

page 34 — — — — — — — — — — —
M12 connector SY7:03 : — —
Top ported Bottom ported Side ported

Type
SY3:0: —
50: SY5:0: — — — — — — — — — — — —
From
page 45 P.45 P.45 P.45 P.73 — —
SY7:0: —
Metal Base

Type
SY3:0: —
51: SY5:0: — — — — — — — — — — — —
From
page 45 P.45 P.45 P.45 P.73 — —
SY7:0: —
Plug-in

Type
SY3:3: —

52: SY5:3: — — — — — — — — — — — —
From
page 65 P.65 P.65 P.65 P.83 — —
SY7:3: —
Top ported Bottom ported Side ported
Connector Connecting Base

Type
SY3:0:
10: SY5:0: — — — — — —
From
page 97 P.97 P.97 P.97 P.115 P.125 P.135 P.145 P.151 P.161 P.173 P.181 P.189 P.197 —
SY7:0:

Type
SY5:0:
Manifold

11: — — — — — — —
From
page 97 P.97 P.97 P.97 P.115 P.125 P.135 P.145 P.151 P.161 P.173 P.181 P.189 P.197
SY7:0:

Type
SY3:3: —

12: SY5:3: — — —
Plug-in

From
page 109 P.109 P.109 P.109 P.121 P.131 P.141 P.157 P.159 P.171 P.179 P.187 P.195 P.203 — —
SY7:3: —
Standard D Option  Made-to-Order (Refer to page 31.)

7
Series SY3000/5000/7000

Valves with
Port Size Manifold Options (Pages 250 to 258) Valve Options Function

Individual SUP block assembly


Individual EXH block assembly

With residual pressure release valve


Back pressure check valve assembly (Manifold installed type)

Silencer (One-touch fitting connection type)

Vacuum release valve with restrictor


Vacuum/Low pressure specification
SY3000/5000 mixed mounting
SY5000/7000 mixed mounting
SUP stop valve spacer with residual pressure release valve

Oil resistant (Other than designated turbine oil)


Double check spacer with residual pressure release valve
One-touch fittings

SUP/EXH blocking disk


Label for blocking disk
Individual SUP spacer
Individual EXH spacer

Different pressures
Interface regulator

Mixed fitting sizes


Reverse pressure
Dual flow fitting

Enclosure IP67
Blanking plate
C3 C4 C6 C8 C10 C12

Plug (White)
Name plate
(N1) (N3) (N7) (N9) (N11)
Straight piping
Straight piping

Straight piping

Straight piping

Straight piping

Straight piping
Elbow piping
1

Elbow piping
1

Elbow piping
1

Elbow piping
1

Elbow piping
1


3
— — — — — — — — — — — — — — D D D — — — — — — — — — — —  — — —
External External
Pilot Pilot


— —
3
4
— — — — — D D D D D D — — — — — — — D — — —  D —
— External Individual External
Pilot SUP Pilot


— —
3
— — — — — D D D D D D — — — — — — — D — — —  — D — — —
— Individual
SUP


— —
4
— — — — — D D D D — D — — — — — — — D — — —  D — —
— External Individual External
Pilot SUP Pilot

— —
— — — D —
2
3
4
— D D D D D D D D D D D D D D P.213  D
— External Individual External
Pilot SUP Pilot
— — — — P.217

— — —
2
3
4
— — — — — D D D D D D D D D D D — D D D P.213  D
— External Individual External
Pilot SUP Pilot
— — P.217


— — —
2
4
— — — — — D D D D — D D D D D D — D D — P.225  D —
— External Individual External
Pilot SUP Pilot
— — P.225

1: Elbow piping may specify size only in millimeters, depending on the port size. Refer to How to Order Manifold for details.

2: Refer to Manifold Specifications on page 93 for details on IP67.

3: Only SY5000/7000

4: Only SY3000/5000
)One-touch fittings Straight piping Elbow piping
(Upward)

8
Manifold Variations ·················································· Page 7 Valve Replacement Parts ······································ Page 21

Optimum Actuation Size Chart of Air Cylinder ······· Page 11 With Residual Pressure Release Valve ················· Page 23

Valve Specifications ··············································· Page 13 Vacuum Release Valve with Restrictor ················· Page 25
(Specifications, Response Time, Weight)
Made-to-Order for Valve ········································ Page 31
Valve Construction ················································· Page 17

Sub-plate

Plug-in Sub-plate Page 32


M12 connector

Plug-in Sub-plate Specifications (M12 Connector)··············································· Page 33

Sub-plate Parts No. ································································································ Page 35

Manifold

Plug-in Metal Base Page 42


Type 50/ Type 51/ Type 52/
Side ported Bottom ported Top ported

Type 50/Side Ported, Type 51/Bottom Ported, Type 52/Top Ported


Plug-in Metal Base ······························································································· Page 43
D-sub connector
D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40]
Flat ribbon cable

Type 50/Side Ported ··························································································· Page 45

Type 51/Bottom Ported ······················································································· Page 45


PC wiring
Type 52/Top Ported ···························································································· Page 65

Wiring Specifications ······························································································ Page 70

EX510 Gateway-type Serial Transmission System [IP20]


EX510
Type 50/Side Ported ··························································································· Page 73

Type 51/Bottom Ported ······················································································· Page 73

Type 52/Top Ported ···························································································· Page 83

Manifold Exploded View [Exploded View, Manifold Parts No.] ······························ Page 89

9
Valve
Manifold

Plug-in Connector Page 92 LOCK

Connecting LOCK

FREE

Type 10/ Type 11/


FREE

Type 12/
Base Side ported Bottom ported Top ported

Sub-plate
Type 10/Side Ported, Type 11/Bottom Ported, Type 12/Top Ported

Plug-in
Plug-in Connector Connecting Base ···································································· Page 93
D-sub PC
connector wiring
D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40/67]······················· Page 97
Flat Terminal
ribbon cable block box Terminal Block Box [IP67] ···················································································· Page 115

Metal Base
Lead wire Circular Lead Wire [IP67]··································································································· Page 125
connector

Circular Connector [IP67] ····················································································· Page 135

Plug-in
EX500 Gateway Decentralized System 2 (128 Points) [IP67] ····························· Page 145
EX500
EX500 Gateway Decentralized System (64 Points) [IP67] ·································· Page 151

Manifold Exploded View


Type 50, 51, 52
EX600 Integrated-type (For Input/Output) Serial Transmission System (Fieldbus System) [IP67] ···· Page 161
EX600

EX250 Integrated-type (For Input/Output) Serial Transmission System [IP67]···· Page 173
EX250

EX260 EX260 Integrated type (For Output) Serial Transmission System [IP67] ············· Page 181

Connector Connecting Base


EX126 Integrated-type (For Output) Serial Transmission System [IP67]············· Page 189
EX126

EX120 Integrated-type (For Output) Serial Transmission System [IP20]············· Page 197
EX120
Type 10/Side ported Common Dimensions

Plug-in
(External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override) ·········· Page 205

Type 11/Bottom Ported Common Dimensions ····················································· Page 208

Manifold Exploded View


Type 10, 11, 12
Type 12/Top Ported Common Dimensions ·························································· Page 210

Plug-in Manifold Mixed Mounting Type ······························································ Page 213


Mixed
mounting
Manifold Exploded View [Exploded View, Manifold Parts No.]····························· Page 229
Plug Assembly Part No.
One-touch Fittings/

How to Increase Connector Type Manifold ·························································· Page 243

One-touch Fittings, Plug Assembly/Part No. ············································································································· Page 248


Manifold Options

Manifold Options [ Plug-in Metal Base, Plug-in Connector Connecting Base] ························································ Page 249

Specific Product Precautions ····································································································································· Page 266

10
Optimum Actuation Size Chart of Air Cylinder
Applicable Applicable cylinder
Main valve
cylinder Series
seal type
speed ø6 ø10 ø16 ø20 ø25

SY3000

Rubber seal SY5000

SY7000
100 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
300 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
500 mm/s
or less
SY3000

Metal seal SY5000

SY7000
[Common conditions]
s0RESSURE-0A
s0IPINGLENGTHM
s,OADRATIO
s3TROKEMM
#ONNECTORTYPEMANIFOLDFORSIDEANDBOTTOMPORTEDTYPE

5SEASAGUIDEFORSELECTION
0LEASECHECKTHEACTUALCONDITIONSWITH3-#-ODEL3ELECTION3OFTWARE


ø32
ø40
ø50
ø63
ø80
Applicable cylinder

ø100
ø125
ø140
ø160


One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000
Valve Specifications
Valve Specifications

Valve type Rubber seal Metal seal


Fluid Air
2-position single 0.15 to 0.7
Internal pilot 2-position double 0.1 to 0.7 (High pressure type: 0.1 to 1)
0.1 to 0.7
operating pressure range
[MPa] 3-position 0.2 to 0.7
4-position dual 3-port valve 0.15 to 0.7 —
Operating pressure range –100 kPa to 0.7 (4-position: –100 kPa to 0.6) –100 kPa to 0.7 (High pressure type: –100 kPa to 1)
External pilot 2-position single
operating pressure range Pilot 2-position double 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to 1)
[MPa] pressure
range 3-position
4-position dual 3-port valve Operating pressure + 0.1 or more (Min. 0.25) to 0.7 —
Ambient and fluid temperature [nC] –10 to 50 (No freezing)
2-position single/double
SY3000 5 20
1
4-position dual 3-port valve
SY5000
Max. operating frequency 3-position 3 10
1
[Hz] 2-position single/double 5 10
1
SY7000 4-position dual 3-port valve 3 —
3-position 3 10
1
Non-locking push type
Push-turn locking slotted type
Manual override
Push-turn locking lever type
Slide locking type
Internal pilot Main/Pilot valve common exhaust Main/Pilot valve individual exhaust
Pilot exhaust type
External pilot Pilot valve individual exhaust
Lubrication Not required
Single: Unrestricted
Mounting orientation
2 Unrestricted
Double/3-position: Main valve is horizontal.
Impact/Vibration resistance
2 [m/s2] 150/30
Enclosure IP67 (Based on IEC60529)
3
Coil rated voltage [DC] 24, 12 V
Allowable voltage fluctuation [V] o10% of rated voltage
4
Standard 0.35 (With indicator light: 0.4)
High pressure type, Quick response type 0.9 (With indicator light: 0.95)
Power consumption [W]
Standard: 0.1
5 (With indicator light only) [Inrush 0.35, Holding 0.1],
With power saving circuit
High pressure type: 0.4
5 (With indicator light only) [Inrush 0.9, Holding 0.4]
Surge voltage suppressor Diode (Varistor for non-polar type)
Indicator light LED

1: Use below 5 Hz for with the power saving circuit.

2: Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized
states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Refer to page 271 for the fixation of DIN rail mounting type manifold.

3: In the case of a metal seal, there are restrictions in the operating environment. Refer to the Specific Product Precautions (page 266).

4: Due to voltage drops by the internal circuit in S/Z type and T type (with power saving circuit), use within the allowable voltage fluctuation as follows.
24 VDC: –7% to +10% 24 VDC: –8% to +10%
S/Z type T type
12 VDC: –4% to +10% 12 VDC: –6% to +10%

5: For details, refer to page 268.

13
Valve Specifications Series SY3000/5000/7000

Valve
Response Time

Response time [ms]


Standard Quick response type

Sub-plate
Series Seal type Model Type of actuation Without light/ With light/surge Without light/ With light/surge
surge voltage voltage suppressor surge voltage voltage suppressor
suppressor S/Z type R/U type suppressor S/Z type R/U type
Rubber seal SY31:0 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less

Plug-in
2-position single
Metal seal SY31:1 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
Rubber seal SY32:0 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY3000 Metal seal SY32:1 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY33/4/5:0 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
3-position
Metal seal SY33/4/5:1 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
Rubber seal SY3A/B/C:0 4-position dual 3-port valve 18 or less 22 or less 18 or less 15 or less 19 or less 15 or less
Rubber seal SY51:0 24 or less 31 or less 18 or less

Metal Base
24 or less 25 or less 18 or less
2-position single
Metal seal SY51:1 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
Rubber seal SY52:0 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY5000 Metal seal SY52:1 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY53/4/5:0 30 or less 34 or less 30 or less 24 or less 28 or less 24 or less

Plug-in
3-position
Metal seal SY53/4/5:1 28 or less 30 or less 28 or less 23 or less 25 or less 23 or less
Rubber seal SY5A/B/C:0 4-position dual 3-port valve 35 or less 42 or less 35 or less 28 or less 35 or less 28 or less
Rubber seal SY71:0 47 or less 58 or less 53 or less 42 or less 52 or less 44 or less
2-position single
Metal seal SY71:1 39 or less 48 or less 39 or less 34 or less 43 or less 34 or less

Manifold Exploded View


Rubber seal SY72:0 18 or less 19 or less 19 or less 18 or less 17 or less 17 or less

Type 50, 51, 52


2-position double
SY7000 Metal seal SY72:1 17 or less 17 or less 16 or less 16 or less 16 or less 16 or less
Rubber seal SY73/4/5:0 52 or less 54 or less 47 or less 42 or less 46 or less 40 or less
3-position
Metal seal SY73/4/5:1 38 or less 45 or less 39 or less 33 or less 38 or less 34 or less
Rubber seal SY7A/B/C:0 4-position dual 3-port valve 52 or less 60 or less 54 or less 49 or less 53 or less 48 or less

Connector Connecting Base


Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

14
Series SY3000/5000/7000

Valve Weight
Series SY3000
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed center SY3:01 Metal seal Closed center
SY3:00 Rubber seal
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) [g] type 4, 2 (A, B) [g]
Single 74 Single 76
2-position 2-position
Double 83 Double 86
SY3:30-M5 Closed center
M5 x 0.8
SY3:31-M5 Closed center M5 x 0.8
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83 Single 84
2-position
Single 82 Double C2 94
2-position
Double
C2
91 SY3:31-C2 Closed center ø2 One-touch
Closed center 3-position Exhaust center fitting 98
SY3:30-C2 ø2 One-touch
3-position Exhaust center 95 Pressure center
fitting
Pressure center Single 87
2-position
4-position Dual 3-port valve 91 Double C3 97
Metal
Single 85 SY3:31-C3 seal Closed center ø3.2 One-touch
2-position
Double 94 3-position Exhaust center fitting 101
C3
Rubber Closed center Pressure center
SY3:30-C3 ø3.2 One-touch
seal 3-position Exhaust center 98 Single 79
fitting 2-position
Pressure center Double C4 89
4-position Dual 3-port valve 94 SY3:31-C4 Closed center ø4 One-touch
Single 77 3-position Exhaust center fitting 93
2-position
Double 86 Pressure center
C4
Closed center Single 82
SY3:30-C4 ø4 One-touch 2-position
3-position Exhaust center 90 Double C6 92
fitting
Pressure center SY3:31-C6 Closed center ø6 One-touch
4-position Dual 3-port valve 86 3-position Exhaust center fitting 96
Single 80 Pressure center
2-position
Double 89
C6
Closed center
SY3:30-C6 ø6 One-touch
3-position Exhaust center 93
fitting
Pressure center
4-position Dual 3-port valve 89

Series SY5000
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 82 Single 91
2-position 2-position
Double 90 Double 101
Closed center SY5:01 Metal seal Closed center
SY5:00 Rubber seal
3-position Exhaust center 3-position Exhaust center
100 111
Pressure center Pressure center
4-position Dual 3-port valve 90

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) [g] type 4, 2 (A, B) [g]
Single 102 Single 111
2-position 2-position
Double 110 Double 121
Closed center SY5:31-01 Closed center 1/8
SY5:30-01 3-position Exhaust center
1/8
Exhaust center
120 3-position 131
Pressure center Pressure center
4-position Dual 3-port valve 110 Single 124
2-position
Single 115 Double C4 134
2-position
Double
C4
123 SY5:31-C4 Closed center ø4 One-touch
Closed center 3-position Exhaust center fitting 144
SY5:30-C4 3-position Exhaust center
ø4 One-touch
Metal Pressure center
133
fitting
Pressure center seal Single 120
2-position
Rubber 4-position Dual 3-port valve 123 Double C6 130
seal
2-position
Single 110 SY5:31-C6 Closed center ø6 One-touch
Double 118 3-position Exhaust center fitting 140
C6
Closed center Pressure center
SY5:30-C6 3-position Exhaust center
ø6 One-touch
Single
128 108
fitting 2-position
Pressure center Double C8 118
4-position Dual 3-port valve 118 SY5:31-C8 Closed center ø8 One-touch
Single 99 3-position Exhaust center fitting 128
2-position
Double 107 Pressure center
C8
Closed center
SY5:30-C8 3-position Exhaust center
ø8 One-touch
117
fitting
Pressure center
4-position Dual 3-port valve 107

15
Valve Specifications Series SY3000/5000/7000

Valve
Valve Weight
Series SY7000
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 110 Single 122
2-position 2-position

Sub-plate
Double 118 Double 133
Closed center SY7:01 Metal seal Closed center
SY7:00 Rubber seal
3-position Exhaust center 133 3-position Exhaust center 150
Pressure center Pressure center
4-position Dual 3-port valve 114

Plug-in
Seal Port size Weight Seal Port size Weight
Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) [g] type 4, 2 (A, B) [g]
Single 125 Single 136
2-position 2-position
Double 133 Double 148
SY7:30-02 Closed center
1/4
SY7:31-02 Closed center 1/4
3-position Exhaust center 147 3-position Exhaust center 164
Pressure center Pressure center
4-position Dual 3-port valve 129 Single 174
2-position

Metal Base
Single 163 Double C6 186
2-position
Double
C6
171 SY7:31-C6 Closed center ø6 One-touch
Closed center 3-position Exhaust center fitting 202
SY7:30-C6 ø6 One-touch
3-position Exhaust center 186 Pressure center
fitting
Pressure center Single 162
2-position
4-position Dual 3-port valve 167 Double C8 174

Plug-in
Metal
Single 151 SY7:31-C8 seal
Closed center ø8 One-touch
2-position
Double 159 3-position Exhaust center fitting 190
C8
Rubber Closed center Pressure center
SY7:30-C8 seal ø8 One-touch
3-position Exhaust center 174 Single 148
fitting 2-position
Pressure center Double C10 159
4-position Dual 3-port valve 155 SY7:31-C10 Closed center ø10 One-touch

Manifold Exploded View


Single 136 3-position Exhaust center fitting 176

Type 50, 51, 52


2-position
Double 144 Pressure center
C10
Closed center Single 157
SY7:30-C10 ø10 One-touch 2-position
3-position Exhaust center 159 Double C12 169
fitting
Pressure center SY7:31-C12 Closed center ø12 One-touch
4-position Dual 3-port valve 140 3-position Exhaust center fitting 185
Single 146 Pressure center
2-position
Double 154
C12
Closed center
SY7:30-C12 ø12 One-touch
3-position Exhaust center 169

Connector Connecting Base


fitting
Pressure center
4-position Dual 3-port valve 150

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

16
Series SY3000/5000/7000
Valve Construction
Rubber Seal
2-position single Top ported
(A) (B)
4 2

= . : @ ; = . : @ ;

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
= . : @ ;

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed center/exhaust center/pressure center


= . : @ ; 3-position closed center 3-position exhaust center
(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)

3-position pressure center


(A)4 2(B)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminum die-casted
Special resin/HNBR
2 Spool valve 3-position valve:
(
Aluminum/HNBR )
3 Piston Resin
Body cover assembly Resin For side/bottom ported
SY3000: Resin
4
Port block assembly SY5000: Zinc die-casted For top ported
SY7000: Aluminum die-casted
5 Pilot valve assembly — Refer to page 22.

17
Valve Construction Series SY3000/5000/7000

Valve
Rubber Seal
4-position dual 3-port valve
4-position dual 3-port valve
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
= . : @ ;

Sub-plate
4(A) 2(B) 4(A) 2(B)

Plug-in
5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)
N.C. valve, N.O. valve 1 pc. of each
5 4 1 2 3
(EA) (A) (P) (B) (EB) 4(A) 2(B)

Metal Base
5(EA) 1(P) 3(EB)

Plug-in
2-position double with back pressure check valve (Built-in valve type)

= . : @ ;
2-position double

Manifold Exploded View


with back pressure check valve

Type 50, 51, 52


(A)4 2(B)

(EA)5 1 3(EB)
(P)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

: The built-in valve type back pressure check valve is not available for the SY7000.

Connector Connecting Base


4-position dual 3-port valve with back pressure check valve (Built-in valve type)

4-position dual 3-port valve with back pressure check valve


= . : @ ; N.C. valve x 2 pcs. N.O. valve x 2 pcs.

Plug-in
4(A) 2(B) 4(A) 2(B)

Manifold Exploded View


Type 10, 11, 12

5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)


5 4 1 2 3 N.C. valve, N.O. valve 1 pc. of each
(EA) (A) (P) (B) (EB)
4(A) 2(B)
Plug Assembly Part No.
One-touch Fittings/

5(EA) 1(P) 3(EB)


: The built-in valve type back pressure check valve is not available for the SY7000.
Manifold Options

18
Series SY3000/5000/7000

Metal Seal
2-position single Top ported
(A) (B)
4 2

= . : @ ; = . : @ ;

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
= . : @ ;

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed center/exhaust center/pressure center


= . : @ ;

3-position closed center 3-position exhaust center


(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)
5 4 1 2 3
(EA) (A) (P) (B) (EB) 3-position pressure center
(A)4 2(B)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminum die-casted
2 Spool, Sleeve Stainless steel/HNBR
3 Piston Resin
Body cover assembly Resin For side/bottom ported
SY3000: Resin
4
Port block assembly SY5000: Zinc die-casted For top ported
SY7000: Aluminum die-casted
5 Pilot valve assembly — Refer to page 22.

19
20
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000
Valve Replacement Parts
How to Order Port Block Assembly
Mounting screw

SY 0V 6A One-touch fitting

Series Thread type


3 3000 Nil Rc
5 5000 F G
7 7000 N NPT
T NPTF
Pilot type
: Except M5
Nil Internal pilot
A, B port size
R External pilot Thread piping
Symbol Port size Applicable series
Option for mounting M5 M5 x 0.8 SY3000
Nil Standard (Valve mounting screw “not” falling-out-prevention type) 01 1/8 SY5000
1 Valve mounting screw falling-out-prevention type 02 1/4 SY7000
Metric size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
C2 ø2 ) — —
C3 ø3.2 ) — —
C4 ø4 ) ) —
C6 ø6 ) ) )
C8 ø8 — ) )
C10 ø10 — — )
C12 ø12 — — )
Inch size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
N1 ø1/8" ) — —
N3 ø5/32" ) ) —
N7 ø1/4" ) ) )
N9 ø5/16" — ) )
N11 ø3/8" — — )

# Possible to replace only the One-touch fitting.


Port size SY3000 SY5000 SY7000
ø2 VVQ1000-50A-C2 — —
ø3.2 VVQ1000-50A-C3 — —
ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Metric size ø6 VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
ø10 — — VVQ2000-51A-C10
ø12 — — KQ2H12-17-X899
ø1/8" VVQ1000-50A-N1 — —
ø5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —
Inch size ø1/4" VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
ø5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
ø3/8" — — VVQ2000-51A-N11

Refer to pages 271 and 272 for how to replace


the port block assembly, One-touch fitting and
body cover assembly.

21
Valve Replacement Parts Series SY3000/5000/7000

Valve
Body Cover Assembly

: Used when the top ported is changed to the side or bottom ported.

Mounting screw

Sub-plate
Part no.
Series Standard (Valve mounting screw Valve mounting screw
“not” falling-out-prevention type) falling-out-prevention type

Plug-in
Internal pilot SY30V-16A SY30V-16A-1
SY3000
External pilot SY30V-16AR SY30V-16AR-1
Internal pilot SY50V-16A SY50V-16A-1
SY5000
External pilot SY50V-16AR SY50V-16AR-1
Internal pilot SY70V-16A SY70V-16A-1
SY7000
External pilot SY70V-16AR SY70V-16AR-1

: The part number is not indicated on the product.

Metal Base
Plug-in
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

V112 A

Manifold Exploded View


How to replace pilot valves

Type 50, 51, 52


Pilot valve option Pilot cover assembly Pilot valve assembly
Nil Standard (0.7 MPa) Series Part no.
B Quick response type (0.7 MPa) SY3000 SY30V-25A
SY5000 Gasket
K High pressure type (1.0 MPa)
1 SY50V-25A
SY7000

1: Only metal seal type is available for a-side pilot valve



Pilot cover x 1 + B tight flat

Connector Connecting Base


the high pressure type. (1.0 MPa) head screw x 1

Coil type
@
Nil Standard Pilot cover
T With power saving circuit
Socket
Rated voltage : @
5 24 VDC

Plug-in
b-side pilot valve
6 12 VDC
B tight flat head screw (M1.7)
Tightening torque: 0.12 N·m Pilot valve mounting screw (M2 x 16.5)

Manifold Exploded View


Caution Tightening torque: 0.15 N·m
1. The coil specification and voltage (including
Type 10, 11, 12
light/surge voltage suppressor) cannot be
changed by changing the pilot valve Pilot valve mounting screw (M2 x 25)
assembly. Tightening torque: 0.15 N·m
2. When selecting the coil type with power
saving circuit, it is not possible to change to s,OOSEN"TIGHTFLATHEADSCREWTOREMOVETHEPILOTCOVERINTHEDIRECTION
high pressure/power saving circuit type.
indicated by the arrow :.
s2EMOVETHEPILOTVALVEMOUNTINGSCREWS
Plug Assembly Part No.
One-touch Fittings/

s2EMOVETHEPILOTVALVEINTHEDIRECTIONINDICATEDBYTHEARROW@.

: Assemble by following the removal procedure in reverse.

: Ensure the gasket is mounted, and take care not to bend the socket.

: Be noted for mounting that there are two types of lengths for the pilot valve mounting
screws.
Manifold Options

22
Series SY5000/7000 RoHS
With Residual Pressure Release Valve
Mountable manifold
SS5Y5/7-50/51 type manifold
SS5Y5/7-(M)10/11 type manifold
Sub-plate single unit (Except top ported type) How to Order (With mounting screw)

SY 5 3 0 0 5 U D 1 E
Series / 4 ) 0 1 6 With residual pressure release valve
5 SY5000 E With residual pressure release valve
1
7 SY7000
1: Mounting screw types, hexagon socket head
cap screw B and screw falling-out-prevention
Type of actuation Base mounted type K, H are not available.
3 3-position closed center
1 (Top ported is not available.) Protective class

1: Only closed center type is available. class  (Mark: )

/ Seal type 0 Rated voltage 6 Manual override


0 Rubber seal 5 24 VDC Nil: D:
1 Metal seal 6 12 VDC Non-locking Push-turn

: The applicable rated voltage varies depending push type locking slotted
on the manifold wiring type. Refer to the “How type
4 Pilot valve option to Order Manifold” pages.
Nil Standard (0.7 MPa)
B Quick response type (0.7 MPa)
Light/surge voltage suppressor
K
1 High pressure type (1.0 MPa)
1 and common specification
Surge voltage Common E: F:

1: Only metal seal type is available for the Symbol With light Push-turn Slide locking
suppressor specification
high pressure type. locking lever type
Nil — — type
) Coil type R — Non-polar
Nil Standard U )
T With power saving circuit (Continuous duty type) S — Positive
)

: Be sure to select the power saving circuit type Z ) common



: Refer to page 31 for with the safety slide
when the valve is continuously energized for NS — Negative locking manual override.
long periods of time. NZ ) common
: When ordering a valve individually, the

: Be careful of the energizing time when the base gasket is not included.

: Only “Z” and “NZ” types are available for with
power saving circuit is selected. Refer to page
the power saving circuit. Since the base gasket is attached to the
268 for details.
manifold, please order the base gasket
separately if it is needed for maintenance service.
Refer to page 89 or 244 for part numbers of the
base gasket and mounting screw.

Valve Specifications Symbol


<When 1(P) port is exhausted> <When 1(P) port is pressurized>

Rubber seal Metal seal EXH. EXH.


Valve construction
3-position closed center valve with residual pressure release valve
1 EXH. EXH.
Fluid Air
4 2 4 2
Operating pressure range MPa
2 0.3 to 0.7 0.3 to 0.7 (High pressure: 0.3 to 1)
SY5000 117 128
Weight [g] 5 3 5 3
SY7000 156 177 1 1

1: Rubber seal is used for the residual pressure release valve. A mechanism is used that exhausts the pressure of the

2: Internal pilot type only cylinder port when the P port supply pressure of the 3

: Other specifications are common to the valve specifications on page 13. position closed center valve is exhausted.

23
With Residual Pressure Release Valve Series SY5000/7000

Valve
Dimensions
SY5000

Sub-plate
(Light/surge voltage suppressor)
116.6
Manual override 84.5

12.6
39.8 30.7
( Push-turn locking slotted
)

Plug-in
type: Press, then rotate it.
4(A) port side : Blue
2(B) port side : Yellow
Manual override part 2 x ø3.2
(For manifold mounting)
A side indicator (Red)
1
Exhausted: Concave
Pressurized: End face EXH port
1.3 15
EXH port

Metal Base
B side indicator (Red)
1

47.6
45.1
(For E type: 60.2)
62.3 (For F type)

Exhausted: Concave

30.1
Pressurized: End face

Plug-in
56.6

Manifold Exploded View


Type 50, 51, 52
SY7000

Manual override 133.2


Push-turn locking slotted
( ) 101.1

Connector Connecting Base


type: Press, then rotate it.
47 37.1
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal) 28.4
2(B) port side : Yellow
16.8
BA

(Light/surge voltage suppressor)


3 x ø3.2
Manual override part (For manifold mounting)

Plug-in
EXH port 18 2.2

14 12
EXH port

Manifold Exploded View


A B
Type 10, 11, 12
51.3
(For E type: 60.2)
62.3 (For F type)

45.5

A side indicator (Red)


1 B side indicator (Red)
1
33.3

Exhausted: Concave Exhausted: Concave


56.6

Pressurized: End face Pressurized: End face


Plug Assembly Part No.
One-touch Fittings/


1: The indicator shows the pressurization status.
Do not push it.
Manifold Options

24
Only for External Pilot

Vacuum Release Valve with Restrictor

Series SY3000/5000
Metal base
Mountable
manifolds Type 50 Type 52
[External pilot] SY3000/5000 From P.45 From P.65
Connector connecting base
Type 10/11 Type 12
SY3000/5000 From P.97 From P.109 How to Order (With mounting screw)

Side ported/Bottom ported SY 3 A 0 R 5 1


Top ported SY 3 A 3 R 5 1 C6
/ 4 ) 0 1 6 2 *
/ Series 4 Pilot type 0 Rated voltage 6 Manual override
3 SY3000 R External pilot 5 24 VDC Nil: D:
5 SY5000 6 12 VDC Non-locking Push-turn
push type locking
slotted
) Coil type 1 Light/surge voltage suppressor and common specification type
Nil Standard Surge voltage Common
Symbol With light
With power saving circuit suppressor specification
T (Continuous duty type) E: F:
Nil — —

: Be sure to select “with power R — Non-polar Push-turn Slide locking


saving circuit” when the U ) locking type
solenoid valve will be energized S — lever
) Positive common type
continuously for long period. Z )

: Note the specified energizing time NS — Negative


when power saving circuit is selected. NZ ) common
Refer to the WEB catalog or the Best
: Refer to page 31 for with the safety slide

: Only “Z” and “NZ” types are available for the product with locking manual override.
Pneumatics No. 1 for details.
power saving circuit.

Protective class
class  (Mark: ) 2 B port size
One-touch fitting (Metric size)
Symbol B port SY3000 SY5000
How to Order Manifold Assembly C4 ø4 One-touch fitting ) )
C6 ø6 One-touch fitting ) )
Example (SS5Y3-10F1-::R) C8 ø8 One-touch fitting — )

3-position 3-port valve with restrictor (24 VDC) One-touch fitting (Inch size)
SY3A0R-5U1 Symbol B port SY3000 SY5000
N3 ø5/32" One-touch fitting ) )
N7 ø1/4" One-touch fitting ) )
N9 ø5/16" One-touch fitting — )

: When selecting the port size for each station, specify on a manifold
specification sheet separately.

: When mounting on the manifold base or sub-plate, the A port is plugged.
When a manifold base or sub-plate is ordered separately, mount a plug
ide on the A port.
Us
tions
Sta
Manifold base (5 stations) 1
2
3 * Type of mounting screw
SS5Y3-10F1-05DR-C6 ide Nil Round head combination screw
Ds B Hexagon socket head cap screw

SS5Y3-10F1-05DR-C6···1 set (Type 10 5-station manifold base part no.)



: When ordering a valve individually, the base gasket is not included.
Since the base gasket is attached to the manifold, please order the base

SY3A0R-5U1 (3-position 3-port with restrictor part no.)····5 sets
gasket separately if it is needed for maintenance service.

The asterisk denotes the symbol for assembly. Refer to the WEB catalog or the Best Pneumatics No.1 for part

Prefix it to the part numbers of the valve etc. numbers of the base gasket and mounting screw.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE

: “B” and “H” cannot be selected for the individual SUP/EXH spacer
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDINORDER assembly or interface regulator.
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

25
Only for External Pilot Vacuum Release Valve with Restrictor Series SY3000/5000

Valve
Valve Specifications

Sub-plate
Valve construction 3-position 3-port valve with restrictor
Seal Rubber seal
Fluid Air
Type of actuation Normally closed

Plug-in
Release pressure port 1(P) 0 to 0.6
Operating pressure
Vacuum pressure port 3(EB), 3/5(E) –100 kPa to 0.7
1
range [MPa]
Pilot X port Release pressure + 0.1 or more (Min. 0.25) to 0.7
Restrictor operation Manual

1: Can be used with positive pressure to suit the application.

: Other specifications are common to the valve specifications on page 13.

: Quick response type is not available.

Metal Base
Weight

Plug-in
Valve model Weight [g]
SY3A0R 90
Port size
Valve model Weight [g]
2(B) port
C4 91
SY3A3R

Manifold Exploded View


C6 93

Type 50, 51, 52


Valve model Weight [g]
SY5A0R 94
Port size
Valve model Weight [g]
2(B) port
Symbol
C4 118
2(B)
Vacuum pad port SY5A3R C6 115
C8 121

Connector Connecting Base


SOL.a SOL.b Response Time

Without light/surge With light/surge voltage suppressor


Valve model
1(P) 3(EB) X
voltage suppressor S/Z type R/U type
Release pressure Vacuum pressure SY3A:R 18 26 18
port port SY5A:R 27 32 27

Plug-in

: P = 0.1 MPa X = 0.5 MPa

Manifold Exploded View


Manifold Flow Rate Characteristics
1
Type 10, 11, 12

Flow Rate Characteristics (When restrictor is fully open)


: Plug-in Metal Base
Port size Valve flow rate characteristics
Manifold type 1, 3 2 1l2 (PlB) 2l3 (BlEB)
(P, EB) (B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-50R (Side ported) 1/8 C6 0.7 0.24 1.0 0.16
Plug Assembly Part No.

SS5Y3-52R (Top ported) 1/8 C6 1.0 0.25 1.1 0.25


One-touch Fittings/

SS5Y5-50R (Side ported) 1/4 C8 1.0 0.30 2.3 0.10


SS5Y5-52R (Top ported) 1/4 C8 1.4 0.16 2.4 0.14

@ Plug-in Connector Connecting Base


Port size Valve flow rate characteristics
Manifold Options

Manifold type 1, 3 2 1l2 (PlB) 2l3 (BlEB)


(P, EB) (B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-10R (Side ported) C8 C6 0.7 0.36 1.2 0.22
SS5Y3-12R (Top ported) C8 C6 1.0 0.26 1.2 0.20
SS5Y5-10R (Side ported) C10 C8 1.0 0.20 2.9 0.17
SS5Y5-11R (Bottom ported) C10 C8 1.0 0.30 3.3 0.24
SS5Y5-12R (Top ported) C10 C8 1.4 0.15 2.6 0.24

1: The value is for manifold base with 5 stations.

: Calculation of effective area S and sonic conductance C: S = 5.0 x C


26
Series SY3000/5000

Restrictor Flow Rate Characteristics [Fluid passage: 1(P)l2(B)]


SY3A0R SY5A0R

500 500
Flow rate [L/min(ANR)]

Flow rate [L/min(ANR)]


400 400
0.6 MPa 0.6 MPa
0.45 MPa 0.45 MPa
300 300
0.3 MPa 0.3 MPa
0.15 MPa 0.15 MPa
200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY3A3R-C4 SY5A3R-C4

500 500
Flow rate [L/min(ANR)]

Flow rate [L/min(ANR)]

400 400
0.6 MPa 0.6 MPa
0.45 MPa 0.45 MPa
300 300
0.3 MPa 0.3 MPa
0.15 MPa 0.15 MPa
200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY3A3R-C6 SY5A3R-C6

500 500
Flow rate [L/min(ANR)]

Flow rate [L/min(ANR)]

0.6 MPa 0.6 MPa


400 400 0.45 MPa
0.45 MPa
0.3 MPa 0.3 MPa
300 300
0.15 MPa 0.15 MPa

200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY5A3R-C8

500
Flow rate [L/min(ANR)]

400 0.6 MPa


0.45 MPa
300 0.3 MPa
0.15 MPa
200

100

0
0 1 2 3 4 5 6
Number of restrictor rotations
27
Only for External Pilot Vacuum Release Valve with Restrictor Series SY3000/5000

Valve
Circuit Example
<Example 1: When the 2-position double solenoid valve is combined with the individual EXH spacer.>
Individual EXH spacer
D side U side

Sub-plate
5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X

Plug-in
(SY3200) (SY3200) (SY3A0R) (SY3A0R) (SY3A0R)
Vacuum release valve
with restrictor

2-position double Individual EXH spacer

SOL.b

SOL.b

SOL.b
solenoid valve

Metal Base
SOL.a

SOL.a

SOL.a
4(A) 2(B) 4(A) 2(B) 3/5(E') 3/5(E') 3/5(E')

Plug-in
2(B) Vacuum pressure port 2(B) Vacuum pressure port 2(B) Vacuum pressure port
Vacuum pad port Vacuum pad port Vacuum pad port

<Example 2: When the 2-position double solenoid valve is combined with the individual EXH block and blocking disk.>

Manifold Exploded View


Type 50, 51, 52
D side U side

5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X
(SY3200) (SY3A0R) (SY3A0R) (SY3200)
Vacuum release valve
Individual EXH block with restrictor ( )
Individual

Connector Connecting Base


EXH block
2-position double
2-position double
solenoid valve
solenoid valve
SOL.b

SOL.b
SOL.a

SOL.a

Plug-in
4(A) 2(B) 4(A)2(B) 4(A) 2(B)
3/5(E') 2(B) 2(B)

Manifold Exploded View

: For standard valve to be combined, both the internal Vacuum pressure port Vacuum pad port Vacuum pad port
pilot and external pilot can be selected. If the pres- Type 10, 11, 12
sure drop may occur when the 1(P) port releases the
vacuum, use the external pilot type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

28
Series SY3000/5000

Dimensions: SY3000
Side ported SY3A0R
83.2
51.1
26.8 12.9
31.8

9.4
B
(Light/surge voltage suppressor) 2 x ø2.1
(For manifold mounting)
Manual override

( Push-turn locking slotted type:


Press, then rotate it. )
4(A): Blue Restrictor
2(B): Yellow
( Tightening torque of needle valve lock
nut should not exceed 0.3 N·m. ) 10 1.2

(With needle fully open 55.7)


52.5
(For E type: 60.2)
62.3 (For F type)

30.1
28.4
56.6

Top ported SY3A3R


83.2
51.1
26.8 12.9
11 20.8
A

9.4
B

(Light/surge voltage suppressor) 2 x ø2.1


(For manifold mounting)
Manual override
One-touch fitting
( Push-turn locking slotted type:
Press, then rotate it. ) [2(B) port]
4(A): Blue Applicable tubing O.D.: ø4, ø5/32"
2(B): Yellow : ø6, ø1/4"

Restrictor

( Tightening torque of needle valve lock


) 10 1.2
(3.2)

nut should not exceed 0.3 N·m.


(With needle fully open 55.7)
52.5
43.8
(For E type: 60.2)
62.3 (For F type)

30.1
28.4
56.6

29
Only for External Pilot Vacuum Release Valve with Restrictor Series SY3000/5000

Valve
Dimensions: SY5000
Side ported
SY5A0R
Bottom ported 103.4

Sub-plate
71.3
(Light/surge voltage suppressor) 39.8 17.5
44.7

1.3

Plug-in
12.6
BA

15
Manual override 2 x ø3.2

( Push-turn locking slotted type:


Press, then rotate it. ) (For manifold mounting)

4(A): Blue Restrictor


2(B): Yellow

Metal Base
( Tightening torque of needle valve lock
nut should not exceed 0.3 N·m. ) 1.3 15

(With needle fully open 56.5)

Plug-in
53.3
(For E type: 60.2)
62.3 (For F type)

30.1
27.6

Manifold Exploded View


56.6

Type 50, 51, 52


Connector Connecting Base
Top ported SY5A3R
103.4
71.3
(Light/surge voltage suppressor)
39.8 17.5
14.5 30.2
1.3

Plug-in
12.6
BA

15

Manifold Exploded View


Manual override 2 x ø3.2 Type 10, 11, 12
( Push-turn locking slotted type:
Press, then rotate it. ) (For manifold mounting)
One-touch fitting
4(A): Blue
[2(B) port]
2(B): Yellow
Applicable tubing O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Restrictor

( Tightening torque of needle valve lock


) 1.3 15
Plug Assembly Part No.
(4.9)

nut should not exceed 0.3 N·m.


One-touch Fittings/
(With needle fully open 56.5)
53.3
45.5

Manifold Options
(For E type: 60.2)
62.3 (For F type)

30.1
27.6
56.6

30
Series SY3000/5000/7000
Made to Order
Please contact SMC for detailed dimensions, specifications and lead times.

Symbol
1 Main Valve Fluororubber Specification -X90
Fluororubber is used for rubber parts of the main valve to allow use in applications such as the following.
· When using a lubricant other than the recommended turbine oil, and there is a possibility of malfunction due to swelling of the spool valve seals.

Applicable valves series SY3; 03 0, SY5; 03 0, SY7; 03 0 (Only rubber seal type)

3 0
SY 5 3 0 1 X90
7

Entry is the same as standard products.


Specifications and performance are the same as standard products.

Symbol
2 With Safety Slide Locking Manual Override -X13
A safety lock is added to the slide locking manual override.
(Refer to page 4.)
3 00
SY 5 31 G1 X13
7

Entry is the same as standard products.


Specifications and performance are the same as standard products.

Symbol
3 Metal Seal Valve, Main/Pilot Valve Common Exhaust -X16
This is the type where the exhaust method of the pilot valve is integrated into the exhaust port of the main valve.
3 0
SY 5 3 1 1 X16
7

Entry is the same as standard products.



: Note that the response time of the valve becomes slower than standard products.
Please contact SMC for details.

31
Plug-in
[IP67 Compliant]
Sub-plate Type

32
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) RoHS

Plug-in Sub-plate Specifications


Manifold type Plug-in sub-plate
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Side ported
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Bottom ported
Piping direction
1(P), 5(EA)/3(EB) port Side ported
Top ported
4(A)/2(B) port Top ported
SUP/EXH port type SUP/EXH individual port [5(EA), 3(EB) individual]
Applicable connector M12 waterproof connector
Internal wiring Positive common, Negative common
SY3000 1/8
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port SY5000 1/4
SY7000 3/8
SY3000 1/8
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port SY5000 1/4
Port size
SY7000 3/8
SY3000 1/8
1(P), 5(EA)/3(EB) port SY5000 1/4
Top ported
SY7000 3/8
4(A)/2(B) port Compliant with the valve.
1
Enclosure (Based on IEC60529) IP67
Side ported 99
SY3000 Bottom ported 109
Top ported 104
Side ported 145
Weight: W [g]
2 SY5000 Bottom ported 172
Top ported 159
Side ported 205
SY7000 Bottom ported 232
Top ported 227

1: Refer to page 13 for valve specifications.

2: The valve and cable weights are not included. To obtain the weight with valves attached, add the valve weights given on page 15, and to include the
cable weight, add the connector cable weight on page 35.

Plug-in Sub-plate Flow Rate Characteristics


Rubber Seal Metal Seal
Sub-plate Fitting port size 1  4/2 4/2  5/3 Sub-plate Fitting port size 1  4/2 4/2  5/3
Series Series
piping location (P,E) (A,B) C b C b piping location (P,E) (A,B) C b C b
Side ported 1/8 1/8 1.8 0.27 1.7 0.26 Side ported 1/8 1/8 1.4 0.14 1.3 0.26
SY3000 Bottom ported 1/8 1/8 1.7 0.23 1.4 0.27 SY3000 Bottom ported 1/8 1/8 1.3 0.13 1.3 0.22
Top ported 1/8 C6 1.3 0.34 1.5 0.27 Top ported 1/8 C6 1.2 0.22 1.4 0.29
Side ported 1/4 1/4 4.2 0.21 4.0 0.26 Side ported 1/4 1/4 3.2 0.13 3.5 0.16
SY5000 Bottom ported 1/4 1/4 4.0 0.19 4.0 0.23 SY5000 Bottom ported 1/4 1/4 3.0 0.12 3.2 0.17
Top ported 1/4 C8 2.9 0.29 4.1 0.33 Top ported 1/4 C8 2.6 0.23 3.2 0.19
Side ported 3/8 3/8 6.5 0.24 6.3 0.23 Side ported 3/8 3/8 4.6 0.10 4.9 0.16
SY7000 Bottom ported 3/8 3/8 6.4 0.22 6.3 0.22 SY7000 Bottom ported 3/8 3/8 4.6 0.10 4.9 0.17
Top ported 3/8 C12 5.4 0.30 6.0 0.27 Top ported 3/8 C12 4.0 0.18 4.7 0.16

: Calculation of effective area S and sonic conductance C: S = 5.0 x C

: The value is for individually operated 2-position type.

33
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) Series SY3000/5000/7000

Valve
How to Order
In the case of Valve + Sub-plate (Built-in valve type part no.)

Sub-plate
SY 3 1 0 0 5 U D 1 C6 W1 01
/ 4 ) 0 1 6 2 * -         

Plug-in
/ Series  Light/surge voltage suppressor and common specification  A, B port thread type (Top ported valve only)
3 SY3000 Surge voltage Common Nil Rc
Symbol With light
5 SY5000 suppressor specification F G
7 SY7000 Nil — — N NPT
R — Non-polar T NPTF
4 Type of actuation U )
: Only Nil is available for M5.
1

Metal Base
Single S — Positive
2-position
2 Double Z )
) common  Type of mounting screw
3 Closed center NS — Negative Nil Round head combination screw
4 3-position Exhaust center NZ ) common B Hexagon socket head cap screw
5 Pressure center
: Only “Z” and “NZ” types are available for with K Round head combination screw (Falling-out-prevention type)

Plug-in
A
1 N.C./N.C. the power saving circuit. H Hexagon socket head cap screw (Falling-out-prevention type)
4-position
B
1 dual 3-port N.O./N.O.
: For “K” and “H”, the valve body cover has a
C
1 N.C./N.O.  Manual override drop prevention construction to stop the

1: Only rubber seal type is available for the Nil: D: mounting screws from falling out when the
4-position dual 3-port valve. Non-locking Push-turn valve is removed for maintenance etc.

: Refer to page 35 when the base gaskets and

Manifold Exploded View


push type locking
) Valve piping type slotted mounting screws are required for

Type 50, 51, 52


type maintenance.
0 Base mounted (Port location: Side, Bottom)
: When using an optional spacer assembly,
3 Top ported (4A, 2B port location: Top) “B” and “H” cannot be selected.

0 Seal type
0 Rubber seal E: F:  Wiring specifications
1 Metal seal Push-turn Slide locking WO Without M12 connector cable
locking lever type W1 With M12 connector cable (300 mm)
1 Pilot type type

Connector Connecting Base


W2 With M12 connector cable (500 mm)
Nil Internal pilot W3 With M12 connector cable (1000 mm)
R External pilot W4 With M12 connector cable (2000 mm)
W7 With M12 connector cable (5000 mm)
6 Back pressure check valve (Built-in valve type)
: When ordering a product with M12 connector
Nil None
: Refer to page 31 for with the safety slide cable, the connector cable is included.
H Built-in locking manual override.

: Only rubber seal type  Port location (Sub-plate)

: The built-in valve type back pressure check  A, B port size (


: Top ported valve only) Nil Side ported
valve is not available for the 3-position type

Plug-in
Thread piping B Bottom ported
and the SY7000.
Symbol Port size Applicable series V
1 Top ported (1P, 5EA, 3EB port: Side ported)
M5 M5 x 0.8 SY3000
2 Pilot valve option 01

1: Only available for the valve piping type “3”

Manifold Exploded View


1/8 SY5000 top ported.
Nil Standard (0.7 MPa)
02 1/4 SY7000 Type 10, 11, 12
B
K
1
Quick response type (0.7 MPa)
High pressure type (1.0 MPa) Metric size (One-touch fitting)
 Port size (Sub-plate)
Symbol Port size Applicable series

1: Only metal seal type is available for the Symbol A, B port SY3000 SY5000 SY7000
01 1/8 SY3000
high pressure type. C2 ø2 ) — —
02 1/4 SY5000
C3 ø3.2 ) — —
* Coil type C4 ø4 ) ) —
03 3/8 SY7000
Nil Standard C6 ) ) )
T With power saving circuit (Continuous duty type) C8
ø6
ø8 — ) )
 Sub-plate thread type
Nil Rc
Plug Assembly Part No.

: Be sure to select the power saving circuit C10 ø10 — — )


One-touch Fittings/

type when the valve is continuously F G


C12 ø12 — — )
energized for long periods of time. N NPT

: Be careful of the energizing time when the Inch size (One-touch fitting) T NPTF
power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000 SY7000
268 for details. N1 ø1/8" ) — —
N3 ø5/32" ) ) —
- Rated voltage
Manifold Options

N7 ø1/4" ) ) )
5 24 VDC N9 ø5/16" — ) )
6 12 VDC N11 ø3/8" — — )

: When mounting a special order (including Made-to-Order specification) valve or manifold option (spacer etc.) on the sub-plate, add the valve part number
or spacer part number under the sub-plate part number to place an order. For details, refer to the ordering example on page 35.

34
Series SY3000/5000/7000

How to Order

In the case of Sub-plate (Sub-plate single unit part no.)



: Without valve
SY 3 0M 27 1 W1 01
/ 4 ) 0 1
: Base gasket is included.

: Valve mounting screws are not included.
/ Series ) Port location (Sub-plate) 1 Sub-plate thread type
3 SY3000 Nil Side ported Nil Rc
5 SY5000 B Bottom ported F G
7 SY7000 V Top ported [1(P), 5(EA), 3(EB) port: Side ported] N NPT
T NPTF
4 Wiring specifications 0 Port size
WO Without M12 connector cable Symbol Port size Applicable series
W1 With M12 connector cable (300 mm) 01 1/8 SY3000
W2 With M12 connector cable (500 mm) 02 1/4 SY5000
W3 With M12 connector cable (1000 mm) 03 3/8 SY7000
W4 With M12 connector cable (2000 mm)
W7 With M12 connector cable (5000 mm)

: Refer to the table below for connector cable


How to Order when mounting a special order (including Made-to-Order specification)
part numbers. valve on the sub-plate (Ordering example: X90)

: When ordering a product with M12 connector


cable, the connector cable is included. SY30M-27-1-W1-01······ 1 set (Sub-plate single unit part no.)

SY3200-5U1-X90·········· 1 set (2-position double part no./Main valve fluororubber specification)

Ordering example when mounting a manifold option (spacer etc.)

SY30M-27-1-W1-01······ 1 set (Sub-plate single unit part no.)



SY3400-5U1 ················· 1 set (3-position exhaust center part no.)

SY30M-60-1A ··············· 1 set (Part no. for double check spacer with residual pressure release valve)

Sub-plate Parts No.

: Part no.

: 3 pcs. No. Description Note
SY3000 SY5000 SY7000
for the SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on
Valve combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) the left are for 10 valves
: mounting
screw Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (20 pcs.).
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) (30 pcs. for the SY7000)
Base gasket Part numbers shown on the
@ (for sub-plate) SY30M-11-1A SY50M-11-1A SY70M-11-1A
left are for 10 valves (10 pcs.).
Cable length: 300 mm
@ ZS-37-L
Cable weight: Approx. 18 g
Cable length: 500 mm
ZS-37-M
Cable weight: Approx. 23 g
M12 waterproof Cable length: 1000 mm
. connector cable ZS-37-N
Cable weight: Approx. 36 g
Cable length: 2000 mm
. ZS-37-P
Cable weight: Approx. 62 g
Cable length: 5000 mm
ZS-37-C
Cable weight: Approx. 140 g

Caution
Tightening torque
M2: 0.16 N·m (SY3000)
M3: 0.8 N·m (SY5000/7000)

35
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) Series SY3000/5000/7000

Plug-in Side Ported

Valve
Dimensions: Series SY3000 Single Unit/Sub-plate Top Ported
SY3:0 01 ::::-:::1-W:-01: (Side ported) 14.5 13.3
For "F" marking 1/8
(Thread type) [4(A), 2(B) port]

Sub-plate
12

19
F

Plug-in
Manual override 83.2

(
Push-turn locking slotted type:
Press, then rotate it. ) 51.1
34.5 8.8 2 x ø3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Gray (For metal seal) 4A 2B
2(B) port side: Yellow

35.9

Metal Base
32.9
BA
14 A

12 B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
(42.1)

10.6
52.2 5.8

11.9

Plug-in
67.9 (15.3)
(For 3-position)
1/8
[1(P) port]

(For E type: 62.2)


(For F type: 64.3)
1: Brown (Unused) 3: Blue (COM.)

Manifold Exploded View


58.6

Type 50, 51, 52


2: White (SOL.b) 4: Black (SOL.a)

28
19.5
17.7

20
Sub-plate side pin arrangement

7.4
Triangle mark
(No numeric indication)
M5 x 0.8 M5 x 0.8
COM. (PE: External pilot EXH port) (X: External pilot port)
1/8 11 11 9.5
3
[5(EA), 3(EB) port]

Connector Connecting Base


4 2
28.6 5.2
SOL.a 1 SOL.b
Unused (Without terminal)

: These figures show the “SY3200-5Z1-WO-01F”.

SY3:3 01 ::::-:::1-::-W:-V01: (Top ported)


Plug

Plug-in
F

Manifold Exploded View


Type 10, 11, 12
(Max. 3)

4A 2B
B A
4 A

2B

PE X
(Light/surge voltage suppressor)
Plug Assembly Part No.

5EA 1P 3EB
One-touch Fittings/

11 15 M5 x 0.8 (For threaded type)


One-touch fitting
[4(A), 2(B) port]
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Manifold Options
(M5 threaded type)
(72.8)
58.6


: These figures show the “SY3230-5Z1-C6-WO-V01F”.

: 1(P), 5(EA), 3(EB), X and PE ports are side ported.
36
Series SY3000/5000/7000

Plug-in
Dimensions: Series SY3000 Single Unit/Sub-plate Bottom Ported
SY3:0 01 ::::-:::1-W:-B01: (Bottom ported)
For "F" marking
Plug
(Thread type)

19
F

Manual override 83.2

(Max. 3)
(Push-turn locking slotted type:
Press, then rotate it. ) 51.1
34.5 8.8 2 x ø3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Gray (For metal seal) 4A 2B
2(B) port side: Yellow

35.9
32.9
B A
14 A

12 B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
(42.1)

10.6

(Max. 3)
52.2 5.8

11.9
Sub-plate side pin arrangement 67.9 (15.3)
(No numeric indication) (For 3-position)

COM.

(For E type: 62.2)


1: Brown (Unused) 3: Blue (COM.)

(For F type: 64.3)


3
4 2

2: White (SOL.b) 4: Black (SOL.a) SOL.a 1 SOL.b

58.6
Unused (Without terminal)

28
19.5

20
Panel fitting dimensions
Triangle mark Plug M5 x 0.8
M5 x 0.8 28.6 5.2 (X: External pilot port)
(PE: External pilot EXH port) Plug
32.5
3.7

14.7
8.2

13 13 7.5
3.5

29.5
5 3 1
28.3

34.5 2 x M3
2 x ø3.4 4 2
42.5 1/8
[1(P), 2(A), 4(B), 5(EA), 3(EB) port] Fitting dimensions for panel mounting
14.5 13.3 Refer to panel fitting dimensions
for details.


: These figures show the “SY3200-5Z1-WO-B01F”.

37
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) Series SY3000/5000/7000

Plug-in Side Ported

Valve
Dimensions: Series SY5000 Single Unit/Sub-plate Top Ported
SY5:0 01 ::::-:::1-W:-02: (Side ported)
For "F" marking 1/4
46.4 10.8
(Thread type) [4(A), 2(B) port]

Sub-plate
M5 x 0.8 18 25 M5 x 0.8
(PE: External pilot EXH port) (X: External pilot port)

15.5

13

17.5

Plug-in
F

Manual override 103.4

(
Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3
(For mounting)
71.3
62 7.4
4(A) port side: Blue (For rubber seal)

Metal Base
: Gray (For metal seal) PE 4A 2B X
2(B) port side: Yellow

32

40
B A
14 A

12 B
(Light/surge voltage suppressor) 5EA 1P 3EB

Plug-in
(42.1)

10.6

11.9
74.6 3.4

90.3 (16.6)
(For 3-position)
Sub-plate side pin arrangement 1/4

Manifold Exploded View


(No numeric indication) [1(P) port]

(For E type: 62.2)


(For F type: 64.3)

Type 50, 51, 52


1: Brown (Unused) 3: Blue (COM.) COM.

58.6
2: White (SOL.b) 4: Black (SOL.a)
3
4 2

28
15.5
13
SOL.a 1 SOL.b

Unused (Without terminal) Triangle mark


18 18 16
1/4

Connector Connecting Base


[5(EA), 3(EB) port]


: These figures show the “SY5200-5Z1-WO-02F”.

SY5:3 01 ::::-:::1-::-W:-V02: (Top ported) Plug

Plug-in
F

Manifold Exploded View


Type 10, 11, 12
(Max. 3)

For "F" marking


14.5 26.8
(Thread type)
<For 01> PE 4A 2B X
F
B A
4 A

2 B

5EA 1P 3EB
Plug Assembly Part No.
One-touch Fittings/

One-touch fitting (16.2) 25.9 1/8 (For threaded type)


[4(A), 2(B) port] (For threaded type) (For threaded type) [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
Manifold Options
(For 01 threaded type)
(76.7)
(62.3)


: These figures show the “SY5230-5Z1-C8-WO-V02F”.

: 1(P), 5(EA), 3(EB), X and PE ports are side ported.
38
Series SY3000/5000/7000

Plug-in
Dimensions: Series SY5000 Single Unit/Sub-plate Bottom Ported
SY5:0 01 ::::-:::1-W:-B02: (Bottom ported)
For "F" marking
(Thread type) 46.4 10.8
M5 x 0.8 M5 x 0.8
Plug
(PE: External pilot EXH port) (X: External pilot port)

15.5

17.5
F

103.4
Manual override

(Max. 3)
71.3
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3
(For mounting)
62 7.4
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal) PE 4A 2B X

(Max. 3)
2(B) port side: Yellow

32

40
B A
14 A

12 B
(Light/surge voltage suppressor) 5EA 1P 3EB

4
(42.1)

10.6
74.6 3.4

11.9
90.3 (16.6)
(For 3-position)

Sub-plate side pin arrangement


(No numeric indication)

(For E type: 62.2)


(For F type: 64.3)
1: Brown (Unused) 3: Blue (COM.)

2: White (SOL.b) COM.


4: Black (SOL.a)

58.6
3

28
4 2

15.5
SOL.a 1 SOL.b
Panel fitting dimensions
Triangle mark Plug
2 x M4
Unused (Without terminal)
2 x ø4.5
Fitting dimensions for panel mounting
Refer to panel fitting dimensions
4.5

32
40

for details.
18 18 16

3.5 57
4

30.5
9.5

62 5 1 3
4 2

1/4 18 25
[1(P), 2(A), 4(B), 5(EA), 3(EB) port]


: These figures show the “SY5200-5Z1-WO-B02F”.

39
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) Series SY3000/5000/7000

Plug-in Side Ported

Valve
Dimensions: Series SY7000 Single Unit/Sub-plate Top Ported
SY7:0 01 ::::-:::1-W:-03: (Side ported) For “F” marking 3/8
54.8 12.6
(Thread type) [4(A), 2(B) port]

Sub-plate
22.5 28.8
M5 x 0.8 M5 x 0.8
(PE: External pilot EXH port) (X: External pilot port)

16
22
23

Plug-in
F

Manual override 116.7


84.6
(
Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3
(For mounting) 73 8.1

Metal Base
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal) PE 4A 2B X

2(B) port side: Yellow

38

46
B A
14 A

12 B
5 EA 1P 3 EB
(Light/surge voltage suppressor)

Plug-in
4
(42.1)

15.7
4.1

11.9
87.2
102.9 (20.6)
(For 3-position)
3/8
Sub-plate side pin arrangement

Manifold Exploded View


[1(P) port]
(No numeric indication)

Type 50, 51, 52


(For E type: 67.9)
(For F type: 70)
1: Brown (Unused) 3: Blue (COM.) COM.

64.3
2: White (SOL.b) 4: Black (SOL.a) 3

30.5
4 2

23
16
SOL.a 1 SOL.b

Unused (Without terminal) Triangle mark


22.5 22.5 17.5

Connector Connecting Base


3/8
[5(EA), 3(EB) port]

: These figures show the “SY7200-5Z1-WO-03F”.

SY7:3 01 ::::-:::1-::-W:-V03: (Top ported) Plug

Plug-in
Manifold Exploded View
Type 10, 11, 12
(Max.3)

PE 4A 2B X
B A
4A

2B

Plug Assembly Part No.

5 EA 1P 3 EB
One-touch Fittings/

One-touch fitting 22.6 30.2 1/4 (For threaded type)


[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
Manifold Options
(For C12: 93.8)
(For 02 threaded type)
(84.5)
(73)


: These figures show the “SY7230-5Z1-C10-WO-V03F”.

: 1(P), 5(EA), 3(EB), X and PE ports are side ported.
40
Series SY3000/5000/7000

Plug-in
Dimensions: Series SY7000 Single Unit/Sub-plate Bottom Ported
SY7:0 01 ::::-:::1-W:-B03: (Bottom ported)
For “F” marking
(Thread type)
54.8 12.6
M5 x 0.8 M5 x 0.8
(PE: External pilot EXH port) Plug (X: External pilot port)

22
23
F

116.7
Manual override

(Max.3)
84.6
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3
(For mounting) 73 8.1
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal) PE 4A 2B X

(Max.3)
2(B) port side: Yellow

38

46
B A
14 A

12 B
5 EA 1P 3 EB
(Light/surge voltage suppressor)

4
(42.1)

15.7 87.2 4.1

11.9
102.9 (20.6)
(For 3-position)

Sub-plate side pin arrangement


(No numeric indication)

(For E type: 67.9)


(For F type: 70)
1: Brown (Unused) 3: Blue (COM.) COM.

64.3
2: White (SOL.b) 4: Black (SOL.a)
3

30.5
4 2

23
SOL.a 1 SOL.b
Panel fitting dimensions Unused (Without terminal) Triangle mark Plug

2 x M4
4.5

2 x ø4.5 Fitting dimensions for panel mounting


Refer to panel fitting dimensions
22.5 22.5 17.5
for details.
46.2
38

13

33

5 1 4

69 2 3

73
3/8 22.5 28.8
[1(P), 2(A), 4(B), 5(EA), 3(EB) port]


: These figures show the “SY7200-5Z1-WO-B03F”.

41
Plug-in

Bottom ported
Side ported
Metal Base

Top ported

42
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 50, 51, 52
Plug-in Metal Base
Manifold Specifications

D-sub connector Flat ribbon cable Serial wiring


Model PG type S5 type
F type P type PH type
J type (EX510)
Manifold type Plug-in metal base
SUP/EXH port type Common SUP/EXH
2 to 9 stations
All double wiring 2 to 4 stations 2 to 8 stations
Valve stations 2 to 12 stations (J type: 2 to 8 stations)
All single wiring 2 to 12 stations 2 to 8 stations 2 to 12 stations

Flat ribbon cable connector


D-sub connector with strain relief
Conforming to Conforming to MIL-C-83503
Applicable connector —
MIL-C-24308
JIS-X-5101 Socket: 26 pins Socket: 20 pins Socket: 10 pins
MIL type MIL type MIL type
Internal wiring Positive common, Negative common
SY3000 1/8
1(P), 3/5(E) port SY5000 1/4
SY7000 3/8

M5 x 0.8, 1/8
SY3000 ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
Port size
1/8, 1/4
4(A), 2(B) port SY5000 ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting

1/4
SY7000 ø6 One-touch fitting, ø8 One-touch fitting, ø10 One-touch fitting, ø12 One-touch fitting
ø1/4" One-touch fitting, ø5/16" One-touch fitting, ø3/8" One-touch fitting

Enclosure (Based on IEC60529) IP40 IP20

43
Type 50, 51, 52
Plug-in Metal Base Series SY3000/5000/7000

Valve
Manifold Flow Rate Characteristics
1/Manifold Weight
Valve Seal Type: Rubber Seal
Port size Valve flow rate characteristics Weight: W [g]
2

Sub-plate
Model 1, 5, 3 4, 2 1l4/2 (PlA/B) 4/2l5/3 (A/BlE) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b Fixed: C: Replaceable: KC:
SS5Y3-50 (Side ported) 1/8 C6 1.1 0.19 1.1 0.15 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 41.5n + 251 48.5n + 251

Plug-in
1/8 C6 1.2 0.31 1.2 0.14
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.29 1.2 0.20 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.6 0.28 2.6 0.14 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.7 0.35 2.8 0.20 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.6 0.26 3.1 0.13 103n + 379
SS5Y7-50 (Side ported) 3/8 C10 3.8 0.27 4.0 0.20 144n + 510 158n + 510
SS5Y7-51 (Bottom ported) 3/8 C10 4.1 0.34 4.8 0.20 150n + 549 172n + 549

Metal Base
SS5Y7-52 (Top ported) 3/8 C10 4.5 0.27 4.9 0.24 164n + 510

Valve Seal Type: Metal Seal

Plug-in
Port size Valve flow rate characteristics Weight: W [g]
2
Model 1, 5, 3 4, 2 1l4/2 (PlA/B) 4/2l5/3 (A/BlE) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b Fixed: C: Replaceable: KC:
SS5Y3-50 (Side ported) 1/8 C6 0.9 0.14 1.0 0.12 39n + 247 43.5n + 247

Manifold Exploded View


SS5Y3-51 (Bottom ported) 1.1 0.10 41.5n + 251 48.5n + 251

Type 50, 51, 52


1/8 C6 1.0 0.21
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.15 1.1 0.14 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.2 0.20 2.3 0.13 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.4 0.26 2.5 0.16 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.4 0.18 2.6 0.12 103n + 379
SS5Y7-50 (Side ported) 3/8 C10 3.2 0.23 3.5 0.18 144n + 510 158n + 510

Connector Connecting Base


SS5Y7-51 (Bottom ported) 3/8 C10 3.5 0.25 4.0 0.16 150n + 549 172n + 549
SS5Y7-52 (Top ported) 3/8 C10 3.5 0.21 3.8 0.18 164n + 510

1: The value is for manifold base with 5 stations and individually operated 2-position type.

2: Weight: W is the value for the D-sub connector manifold.


To obtain the weight with valves attached, add the valve weights given on page 15 for the appropriate number of stations.

: Calculation of effective area S and sonic conductance C: S = 5.0 x C

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

44
Plug-in Metal Base
Type 50
Side Ported D-sub Connector Flat Ribbon Cable PC Wiring

Series SY3000/5000/7000
Type 51
Bottom Ported

RoHS
How to Order Manifold

SS5Y 3 50 F 1 05 D C6
/ 4 ) 0 1 6 2 * - 
/ Series 4 Type ) Connector type
3 SY3000 50 Side ported F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 51 Bottom ported (25 pins) (26 pins) (20 pins)
7 SY7000 50R Side ported, External pilot

%XTERNALPILOTISNOTAVAILABLE
for the bottom ported type.

0 Connector entry direction


1: Upward 2: Lateral PH: Flat ribbon cable J: PC wiring
(10 pins) (20 pins)

1 Wiring type
Nil All double wiring
1
S All single wiring
2
How to Order Manifold Assembly
1: All double wiring: 2-position single, double, 3-position and 4-position
VALVESCANBEUSEDONALLMANIFOLDSTATIONS

!LLSINGLEWIRING!VAILABLEONLYFORTHEMANIFOLDWHICHHAS POSITION
Example (SS5Y3-50F2-:) single for all stations.
2-position double (24 VDC) .OTETHAT POSITIONDOUBLE  OR POSITIONVALVESCANNOTBEUSED
2-position single (24 VDC)
SY3200-5U1 (1 set)
)FAMIXOFSINGLEANDDOUBLEWIRINGISREQUIRED ITISSUPPLIEDASA
SY3100-5U1 (3 sets)
3-position closed special order.
center (24 VDC)
SY3300-5U1 (1 set)

6 Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
Symbol Stations Note Symbol Stations Note Symbol Stations Note
ide 02 2 stations All 02 2 stations All 02 2 stations All
Us
double double double
s
n

12 12 stations wiring 12 12 stations wiring 09 9 stations wiring


tio
ta
S

Manifold base 3 02 2 stations All 02 2 stations All 02 2 stations All


(5 stations) 2 single single single
1
SS5Y3-50F2-05D-C6 ide wiring wiring wiring
Ds
12 12 stations 12 12 stations 12 12 stations
PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
SS5Y3-50F2-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.) Symbol Stations Note Symbol Stations Note

SY3100-5U1 ················· 3 sets (2-position single part no.) 02 2 stations All 02 2 stations All

SY3200-5U1 ················· 1 set (2-position double part no.) double double

SY3300-5U1 ················· 1 set (3-position closed center part no.) wiring wiring
04 4 stations 08 8 stations
The asterisk denotes the symbol for assembly. 02 2 stations All 02 2 stations All
Prefix it to the part numbers of the valve etc.
single single
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE 08 8 stations wiring 12 12 stations wiring
s 5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDINORDER

: This also includes the number of blanking plate assembly.
FROMTHESTSTATIONASSHOWNINTHEFIGUREABOVE)FTHEARRANGEMENT
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 66.


)NTHISCASE USECAUTIONASTHEREISALSOOUTPUTONTHE!AND"PORTONBASESIDE
3PECIFYONAMANIFOLDSPECIFICATIONSHEETIFPLUGSAREREQUIREDONTHE!AND"PORT
on base side.
45
Plug-in Metal Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
2 P, E port entry * A, B port size
U U side
1 Thread piping
D D side
1
2 Symbol A, B port SY3000 SY5000 SY7000
B Both sides M5 M5 x 0.8 ) — —

1: Plugs are mounted on the opposite 01 1/8 ) ) —

Metal Base
side of the selected ports. 02 1/4 — ) )

2: Only D side is available for Type 51


(Bottom ported). One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
C2 ø2 ) — —
- Thread type

Plug-in
Nil Rc C3 ø3.2 ) — —
Fixed

F G C4 ø4 ) ) —
N NPT C6 ø6 ) ) —
T NPTF C8 ø8 — ) )

Manifold Exploded View


C10 ø10 — — )

Type 50, 51, 52


 Mounting KC2 ø2 ) — — Type 50 Type 51
Nil Direct mounting KC3 ø3.2 ) — — (Side ported) (Bottom ported)
D DIN rail mounting (With DIN rail) KC4
Replaceable

ø4 ) ) —
D0 DIN rail mounting (Without DIN rail)
KC6 ø6 ) ) )
D3 For 3 stations
Specify a longer rail than KC8 ø8 — ) )
···

···

the standard length.


D12 For 12 stations KC10 ø10 — — )

Connector Connecting Base

: Only direct mounting is available for Type 51 KC12 ø12 — — )


(Bottom ported).

: Refer to page 271 for the fixation of DIN rail


M
1 Mixed sizes ) ) )
mounting type manifold. P, E port size (Thread piping) 1/8 1/4 3/8
One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
N1 ø1/8" ) — —
N3 ø5/32" ) ) —
Fixed

N7 ø1/4" ) ) —

Plug-in
N9 ø5/16" — ) )
N11 ø3/8" — — )

Manifold Exploded View


KN1 ø1/8" ) — — Type 50 Type 51
(Side ported) (Bottom ported) Type 10, 11, 12
KN3
Replaceable

ø5/32" ) ) —
KN7 ø1/4" ) ) )
KN9 ø5/16" — ) )
KN11 ø3/8" — — )
M
1 Mixed sizes ) ) )
P, E port size (Thread piping) 1/8 1/4 3/8

1: When ports are mixed sizes, indicate the piping specifications on the
Plug Assembly Part No.
One-touch Fittings/

manifold specification sheet.


Manifold Options

Protective class
class  (Mark: )
46
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted type
high pressure type.
4 Type of actuation
1
2-position
Single 2 Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center locking lever type

: Be sure to select the power saving circuit
5 Pressure center type
type when the valve is continuously
A
1 N.C./N.C. energized for long periods of time.
4-position
B
1 N.O./N.O.
: Be careful of the energizing time when the
dual 3-port
C
1 N.C./N.O. power saving circuit is selected. Refer to page
268 for details.

1: Only rubber seal type is available for the


4-position dual 3-port valve.
: Refer to page 31 for with the safety slide
locking manual override.
* Rated voltage
5 24 VDC
) Seal type 6 12 VDC  Type of mounting screw
0 Rubber seal
Nil Round head combination screw
1 Metal seal
B Hexagon socket head cap screw
- Light/surge voltage suppressor K Round head combination screw (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw (Falling-out-prevention type)
0 Pilot type Surge voltage Common
: For “K” and “H”, the valve body cover has a
Nil Internal pilot Symbol With light drop prevention construction to stop the
suppressor specification
R External pilot mounting screws from falling out when the
Nil — —
valve is removed for maintenance etc.
R — Non-polar
: When ordering a valve individually, the
U ) base gasket is not included.
1 Back pressure check valve S —
)
Positive Since the base gasket is attached to the
(Built-in valve type) Z ) common manifold, please order the base gasket
NS — Negative separately if it is needed for maintenance
Nil None service.
H Built-in NZ ) common
Refer to page 89 for part numbers of the

: Only rubber seal type


: Only “Z” and “NZ” types are available for with base gasket and mounting screw.

: Back pressure check valve is not available the power saving circuit.
: “B” and “H” cannot be selected for the
for the 3-position type and the SY7000. individual SUP/EXH spacer assembly,
interface regulator or double check spacer
assembly with residual pressure release
valve.

Protective class
class  (Mark: )
47
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY3000 Metal Base D-sub Connector

U M5
SS5Y3-50(R)F 12 - Stations D - KC
C:, N: :(D)
:, KN: B
D side U side
L3

Sub-plate
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
(Pitch)
JIS-X-5101
( ) DIN rail holding screw
(
Push-turn locking slotted type:
)

Plug-in
Applicable connector: D-sub equivalent 45.1 P = 10.5
MIL-C-24308 (For DIN rail mounting) Press, then rotate it.
14 24.1 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw (7.9) voltage 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting) suppressor)

DIN rail

(Connector entry
B A B A B A B A B A
upward direction)

Metal Base
92.7
89
5EA

PE

14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

Plug-in
2 x M2.6 4 x ø4.5
8.6 L2 8
)

(For mounting) 4
Replaceable: 7.7

2 x 4-40 UNC
14.5 [For N or T thread] (L5) L1
22.1
Fixed: 4.1

6.1 (Station 1)---(Station n)


28

Manifold Exploded View


Type 50, 51, 52
1/8

manual override)
(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]
7.1

32
22.6
4A 4A

50RF 12 - Stations UD

(For DIN rail

Connector Connecting Base


mounting)
7.5
C2, C3: 5.4

11.8
3 C4, C6: 6.6
[Plug for external pilot] C2, C3: 42.4 (Pitch)
2B
C4, C6: 41.8 P = 10.5 One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"

: The above drawing shows when P, : ø6, ø1/4"

Plug-in
E port entry is D.

: These figures show the “SS5Y3-50F2-05B-C6”.

Port size M5 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12

2B 2B
7.1

7.1
32

32
22.6

22.6

4A 4A

M5 x 0.8
6.6 (Pitch)
Plug Assembly Part No.

[4(A), 2(B) port]


One-touch Fittings/

(Pitch) 48.4 P = 10.5


41.8 P = 10.5
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

48
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base D-sub Connector

U
SS5Y3-50(R)F 12 - Stations D -01:(D)
B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) DIN rail holding screw 45.1
(Pitch)
P = 12.5 (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) 4(A) port side : Blue (For rubber seal)
(Light/surge
DIN rail bracket mounting screw (7.9) : Gray (For metal seal)
[Pilot EXH port] voltage
suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

(Connector entry B A B A B A B A B A

92.7
upward direction)

89
5EA

14 A 14 A 14 A 14 A 14 A
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

8.6 2 x M2.6 4 x ø4.5 4 L2 8


2 x 4-40 UNC (For mounting)
14.5 [For N or T thread] (L5) L1
22.1
(Station 1)------(Station n)
28 6.1

1/8

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]
7.1

32
22.6
4A 4A

(For DIN rail


mounting)
6.6
50RF 12 - Stations UD (Pitch) 7.5
11.8
41.8 P = 12.5 1/8
[4(A), 2(B) port]

3
[Plug for external pilot]
2B

: These figures show the “SS5Y3-50F2-05B-01”.
4A


: The above drawing shows when P,
E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

49
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY5000 Metal Base D-sub Connector

U 01
SS5Y5-50(R)F 12 - Stations D - KC
C:, N: :(D)
:, KN: B D side U side
L3

Sub-plate
5.3 L4 Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent) DIN rail holding screw
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 50 P = 16 (Light/surge 4(A) port side : Blue (For rubber seal)

Plug-in
M5 x 0.8 (External pilot) 16 24.1 voltage : Gray (For metal seal)
[Pilot EXH port] DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
(7.9)
(For DIN rail mounting)

DIN rail

(Connector entry B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
upward direction)

5.5
23.2

116.6
96.2

35
20

Metal Base
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2

8
X

12 B 12 B 12 B 12 B 12 B

Plug-in
4 x ø4.5
)

12.3 (For mounting) 5 L2


Replaceable: 8.5

2 x M2.6
18 (L5) L1
2 x 4-40 UNC
Fixed: 4.9

28 [For N or T thread]
6.1 (Station 1)----------- (Station n)
34

Manifold Exploded View


Type 50, 51, 52
1/4

manual override)
(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(74.7)

M5 x 0.8 (External pilot)

74.3
68.6
60.7

[External pilot port] 2B 2B

7.8

38
27.3
4A
50RF 12 - Stations UD
4A

10

Connector Connecting Base


(For DIN rail
mounting)
3 8.4 (Pitch)

14.3
[Plug for external pilot] 45.8 P = 16
2B
One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

: The above drawing shows when P,
E port entry is D.
: These figures show the “SS5Y5-50F2-05B-C8”.

Plug-in
Port size 01 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12

2B 2B
9.8
7.8

38

38
27.3

27.3

4A 4A
Plug Assembly Part No.

8.4 (Pitch)
(Pitch)
One-touch Fittings/

51.6 P = 16
45.8 P = 16
One-touch fitting
1/8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

50
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base D-sub Connector

U
SS5Y5-50(R)F 12 - Stations D -02:(D)
B

D side U side
L3
5.3 L4
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (DIN rail mounting hole pitch: 12.5) Manual override
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
M5 x 0.8 (External pilot) (Light/surge 4(A) port side : Blue (For rubber seal)
[Pilot EXH port] DIN rail bracket mounting screw 16 24.1 voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor) 2(B) port side : Yellow

DIN rail

(Connector entry B A B A B A B A B A
upward direction)
PE

14 A 14 A 14 A 14 A 14 A
5EA

106.2
5.5
23.2

116.6
96.2

35
20
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B 8

4 x ø4.5
12.3
(For mounting) 5 L2
18 2 x M2.6 (L5) L1
28 2 x 4-40 UNC
[For N or T thread]
34 6.1 (Station 1) ------------- (Station n)

1/4

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]
(74.7)

74.3
M5 x 0.8 (External pilot)

68.6
60.7

2B 2B
[External pilot port]

9.8

38
27.3
4A 4A

10

(For DIN rail


mounting)
8.4 (Pitch) 1/4

14.3
[4(A), 2(B) port]
50RF 12 - Stations UD 45.8 P = 17.5

3
[Plug for external pilot]
2B

4A


: These figures show the “SS5Y5-50F2-05B-02”.


: The above drawing shows when P,
E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

51
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY7000 Metal Base D-sub Connector

U 02
SS5Y7-50(R)F 12 - Stations D - KC
C:, N: :(D)
:, KN: D side U side
B
L3

Sub-plate
5.3 L4
Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent) (DIN rail mounting hole pitch: 12.5)

(Pitch) ( Push-turn locking slotted type:


)
DIN rail holding screw Press, then rotate it.
52 P = 19
M5 x 0.8 (External pilot) (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)

Plug-in
16 24.1 (Light/surge voltage : Gray (For metal seal)
PE: Pilot EXH port DIN rail bracket mounting screw
(7.9) suppressor) 2(B) port side: Yellow
(For DIN rail mounting)

(DIN rail)

B A B A B A B A B A

5.5
(Connector entry
PE

14 A 14 A 14 A 14 A 14 A
5EA

upward direction)

116.7
23.8
28
102.1

35

133.2

Metal Base
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
44.1

2 x M2.6 8
3EB
X

32.1

2 x 4-40 UNC 12 B 12 B 12 B 12 B 12 B

[For N or T thread]

NC
NC

Plug-in
18.1
(5.4)

4 x ø4.5
20.9 (For mounting) 5 L2
34.5 (L5) L1
M5 x 0.8 (External pilot)
40.5
X: External pilot port

Manifold Exploded View


3/8

Type 50, 51, 52


[1(P), 5(EA), 3(EB) port] 6.1 (Station 1) (Station n)

(Slide locking manual override)


50RF 12 - Stations UD
(81.2)

78.3
84
67.2

2B 2B

44.5
9.4
32.4
3 4A 4A

Connector Connecting Base


[Plug for external pilot]

2B

(For DIN rail


10.8 10

mounting)
(Pitch)
14.3
4A
46.6 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø8, ø5/16"

: The above drawing shows when P, : ø10, ø3/8"
E port entry is D.

Plug-in

: These figures show the “SS5Y7-50F2-05B-C10”.

Port size 02 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12

2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A
Plug Assembly Part No.

(Pitch)
One-touch Fittings/

10.8 (Pitch) 55.7 P = 19


46.6 P = 19 (11)
One-touch fitting
1/4 (22.9) [4(A), 2(B) port]
[4(A), 2(B) port] (For ø12) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
Manifold Options

: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
52
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P
U M5
SS5Y3-50(R) PG 1
PH 2 - Stations D - KC
C:, N:
:, KN:
:(D)
J B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
Applicable connector:
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) DIN rail holding screw 45.1
(Pitch)
P = 10.5
(Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) Triangle mark : Gray (For metal seal)
voltage
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
(Connector entry

92.7
PE
5EA

89
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
upward direction)
64.4

35

56.9
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 M5 x 0.8 (External pilot) L2


)

4 8
Replaceable: 7.7

[External pilot port]


14.5 4 x ø4.5 (L5) L1
1/8 (For mounting)
Fixed: 4.1

22.1
[1(P), 5(EA), 3(EB) port] (Station 1)---(Station n)
28
18
(

manual override)
50PJG (20 pins) 50PH (10 pins)

(Slide locking
(80.6)

Triangle mark

68.3
62.6
56.7

Triangle mark
For PC wiring 2B 2B

7.1

32
22.6
4A 4A

(For DIN rail


mounting)
7.5
C2, C3: 5.4
5EA

5EA
PCW type
PE

PE

11.8
C4, C6: 6.6
1P

1P

C2, C3: 42.4 (Pitch)


X

X
3EB

3EB

C4, C6: 41.8 P = 10.5 One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D.: ø2
Applicable connector: Applicable connector: : ø3.2, ø1/8"
20 pins MIL type with strain relief 10 pins MIL type with strain relief : ø4, ø5/32"
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) : ø6, ø1/4"


: These figures show the
Port size M5 One-touch fitting (Replaceable)
“SS5Y3-50P2-05B-C6”.

: Only connectors are different for
50PG, 50PH and 50J.
L1 to L5 dimensions are the same
as 50P type.

2B 2B
50R PJ: 12 - Stations UD
7.1

7.1
32

32
22.6

22.6

4A 4A

3
6.6 M5 x 0.8 (Pitch) [Plug for external pilot]
[4(A), 2(B) port] 48.4 P = 10.5 2B
(Pitch)
41.8 P = 10.5 One-touch fitting 4A

[4(A), 2(B) port]


Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: The above drawing shows when P,
: ø6, ø1/4" E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

53
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P
U
SS5Y3-50(R) PG 1
PH 2 - Stations D -01:(D)
J B
D side U side

Sub-plate
L3

Applicable connector: 5.3 L4 Manual override


(DIN rail mounting hole pitch: 12.5)
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
DIN rail holding screw 45.1 P = 12.5 4(A) port side : Blue (For rubber seal)
Triangle mark : Gray (For metal seal)
(For DIN rail mounting) 14 24.1 (Light/surge
M5 x 0.8 (External pilot) voltage 2(B) port side : Yellow
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor)
(For DIN rail mounting)
DIN rail

B A B A B A B A B A

92.7

Metal Base
89
5EA

PE

14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

Plug-in
8.6 4 x ø4.5 4 L2 8
(For mounting)
14.5 (L5) L1
22.1 (Connector entry
upward direction) (Station 1) ----- (Station n)
28
18

Manifold Exploded View


Type 50, 51, 52
1/8

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]
(80.6)

68.3
62.6
56.7

M5 x 0.8 (External pilot) 2B 2B


[External pilot port]
7.1

32
22.6
4A 4A

(For DIN rail

Connector Connecting Base


6.6

mounting)
(Pitch)

7.5
50PJG (20 pins)

11.8
50PH (10 pins) 41.8 P = 12.5
1/8
Triangle mark
[4(A), 2(B) port]
For PC wiring Triangle mark


: These figures show the “SS5Y3-50P2-05B-01”.

: Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.
5EA

5EA
PCW type
PE

PE

Plug-in
50R PJ: 12 - Stations UD
1P

1P
X

X
3EB

3EB

Manifold Exploded View


3 Type 10, 11, 12
Applicable connector: Applicable connector: [Plug for external pilot]
2B
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) 4A


: The above drawing shows when P,
E port entry is D.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

54
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P
U 01
SS5Y5-50(R) PG 1
PH 2 - Stations D - KC
C:, N:
:, KN:
:(D) D side U side
J B L3
Applicable connector: 5.3 L4
Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(Conforming to MIL-C-83503)
Triangle mark
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge
M5 x 0.8 (External pilot) 16 24.1 : Gray (For metal seal)
DIN rail bracket mounting screw voltage
[Pilot EXH port] (9.9) suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
PE

14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA

106.2
5.5
23.2

116.6
96.2

35
20

upward direction)
81.6

74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2

8
X

12 B 12 B 12 B 12 B 12 B

12.3
)

5 L2
Replaceable: 8.5

18 4 x ø4.5
(L5) L1
28 (For mounting)
Fixed: 4.9

34 M5 x 0.8 (External pilot)


[External pilot port] (Station 1) ----------- (Station n)
1/4 18
[1(P), 5(EA), 3(EB) port]
(

manual override)
50PJG (20 pins) 50PH (10 pins)

(Slide locking
(86.6)

Triangle mark

74.3
68.6
Triangle mark
62.7

2B 2B
For PC wiring

7.8

38
27.3
4A 4A

10

(For DIN rail


PCW type

mounting)
8.4
PE

PE
5EA

5EA

(Pitch)

14.3
45.8 P = 16
1P

1P

One-touch fitting
[4(A), 2(B) port]
3EB

3EB
X

Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
: ø8, ø5/16"

Applicable connector: Applicable connector:


: These figures show the “SS5Y5-50P2-05B-C8”.
20 pins MIL type with strain relief 10 pins MIL type with strain relief
: Only connectors are different for 50PG, 50PH and 50J.
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) L1 to L5 dimensions are the same as 50P type.

Port size 01 One-touch fitting (Replaceable) 50R PJ: 12 - Stations UD

3
[Plug for external pilot]
2B

2B
2B 4A
9.8

38
27.3
7.8

38
27.3

4A
4A

One-touch fitting
: The above drawing shows when P,
(Pitch) [4(A), 2(B) port] E port entry is D.
8.4 (Pitch)
51.6 P = 16 Applicable tube O.D.: ø4, ø5/32"
45.8 P = 16 : ø6, ø1/4"
1/8 : ø8, ø5/16"
[4(A), 2(B) port]

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

55
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P
U
SS5Y5-50(R) PG 1
PH 2 - Stations D -02:(D) D side U side
J B L3

Sub-plate
Applicable connector: 5.3 L4 Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(Conforming to MIL-C-83503)
Triangle mark
DIN rail holding screw
(For DIN rail mounting)
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
50 4(A) port side : Blue (For rubber seal)

Plug-in
M5 x 0.8 (External pilot) 16 24.1 (Light/surge : Gray (For metal seal)
DIN rail bracket mounting screw
voltage suppressor) 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting) (9.9)

DIN rail

B A B A B A B A B A
PE

14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA

106.2
5.5
23.2

116.6
96.2

35
20

upward direction)
81.6

Metal Base
74.1
20
1P
24.6
20

52.2

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B 8

Plug-in
12.3
5 L2
18
(L5) 4 x ø4.5
M5 x 0.8 (External pilot) L1
28 (For mounting)
[External pilot port]
34
1/4 (Station 1) ------------- (Station n)

Manifold Exploded View


[1(P), 5(EA), 3(EB) port] 18

Type 50, 51, 52


50PJG (20 pins) 50PH (10 pins)

manual override)
(Slide locking
(86.6)

Triangle mark
Triangle mark

74.3
68.6
For PC wiring
62.7

2B 2B

9.8

38
27.3
4A 4A

Connector Connecting Base


10
PCW type
PE

PE
5EA

5EA

(For DIN rail


1/4

mounting)
8.4
(Pitch)

14.3
[4(A), 2(B) port]
45.8 P = 17.5
1P

1P
3EB

3EB
X


: These figures show the “SS5Y5-50P2-05B-02”.

: Only connectors are different for 50PG, 50PH and 50J.
Applicable connector: Applicable connector: L1 to L5 dimensions are the same as 50P type.
20 pins MIL type with strain relief 10 pins MIL type with strain relief

Plug-in
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

50R PJ: 12 - Stations UD

Manifold Exploded View


Type 10, 11, 12
3
[Plug for external pilot]
2B

4A
Plug Assembly Part No.


: The above drawing shows when P,
One-touch Fittings/

E port entry is D.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

56
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY7000 Metal Base Flat Ribbon Cable

P
U 02
SS5Y7-50(R) PG 1
PH 2 - Stations D - KC
C:, N:
:, KN:
:(D) D side U side
J B
L3
Applicable connector: 5.3 L4
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5) Manual override
(Conforming to MIL-C-83503)
Triangle mark DIN rail holding screw 52
(Pitch)
P = 19
( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
M5 x 0.8 (External pilot) 16 24.1 (Light/surge voltage : Gray (For metal seal)
DIN rail bracket mounting screw suppressor)
PE: Pilot EXH port (9.9) 2(B) port side: Yellow
(For DIN rail mounting)
(DIN rail)

B A B A B A B A B A
PE

14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA

116.7
5.5
upward direction)
23.8

35
28
102.1

133.2
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
44.1

8
3EB
X

32.1

12 B 12 B 12 B 12 B 12 B

NC
NC
4 x ø4.5
18.1
(5.4)

(For mounting) 5 L2
20.9
M5 x 0.8 (External pilot) (L5) L1
34.5
40.5 X: External pilot port
(Station 1) (Station n)
3/8 18
[1(P), 5(EA), 3(EB) port]

manual override)
(Slide locking
50PJG (20 pins)
(93.1)

50PH (10 pins)

78.3
84
For PC wiring Triangle mark Triangle mark
69.2

2B 2B

44.5
9.4
32.4
4A 4A
PE

PE
PCW type
5EA

5EA

(For DIN rail


10.8

mounting)
10
(Pitch)

14.3
46.6 P = 19
1P

1P

One-touch fitting
[4(A), 2(B) port]
3EB

3EB
X

Applicable tube O.D.: ø8, ø5/16"


: ø10,ø3/8"


: These figures show the “SS5Y7-50P2-05B-C10”.
Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

Port size 02 One-touch fitting (Replaceable) 50RF12 - Stations UD

3
[Plug for external pilot]

2B 2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A 4A

10.8 55.7 (Pitch) P = 19


(Pitch)
: The above drawing shows when P,
46.6 P = 19 One-touch fitting E port entry is D.
(11)
[4(A), 2(B) port]
1/4 Applicable tube O.D.: ø6 ,ø1/4"
(22.9)
[4(A), 2(B) port] : ø8, ø5/16"
(For ø12) : ø10, ø3/8"
: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
57
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Valve
Dimensions: Series SY3000 Metal Base D-sub Connector

M5, 01
SS5Y3-51F 12- Stations D- CKC::, N, :
KN:
: D side U side
Manual override

(Light/surge voltage suppressor) (Push-turn locking slotted type:


)

Sub-plate
Press, then rotate it.
(Pitch) 4(A) port side : Blue (For rubber seal)
2 x M2.6
45.1 P = 10.5 : Gray (For metal seal)
2 x 4-40 UNC
14 24.1 2(B) port side : Yellow
[For N or T thread]
(7.9)
4 x ø4.5

Plug-in
(For mounting)
B A B A B A B A B A

92.7
16

89
14 A 14 A 14 A 14 A 14 A

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Max. 3) L1

Metal Base
6.1 (Station 1) ---(Station n)

manual override)
(Slide locking
(68.7)

68.3
62.6
54.7
Panel fitting dimensions

Plug-in
32
(For 9 stations or more)

(4.1)
2 x ø4.5
(For 9 stations or more) (Pitch)
4

46.4 P = 10.5 One-touch fitting


40 [4(A), 2(B) port]

Manifold Exploded View


23.6
17.8

(For 9 stations or more) Applicable tube O.D.: ø2

Type 50, 51, 52


4 x M4 x 0.7, thread depth 4
4 x ø4.5 (For mounting) : ø3.2, ø1/8"

21.1
16.8

: ø4, ø5/32"
52.4
56.4
16

: ø6, ø1/4"
29.8

3EB 2B 2B
4 x M4 x 0.7 56.4
4 x ø4.5 4 4
1P

5EA 4A 4A

L3
16.8

Fitting dimensions for panel mounting


L2 1/8
C2, C3, C4 : 16
: 15

Refer to panel fitting dimensions for details.

Connector Connecting Base


[1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3
(For 9 stations or more) L2
C6


: These figures show the “SS5Y3-
Port size M5 Port size 01 One-touch fitting (Replaceable)
51F2-05D-C6”.
32

32

32

Plug-in
)C6: 12.8
N7: 16.6

(Pitch) (Pitch) (Pitch)


P = 12.5 P = 10.5
21.1

46.4 P = 10.5 46.4 46.4

Manifold Exploded View


20.1

20.1

Type 10, 11, 12


(
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Plug Assembly Part No.

Applicable tube O.D.: ø2


One-touch Fittings/

: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

Port Size M5, C:, N:, KC:, KN:


n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

58
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY5000 Metal Base D-sub Connector

01, 02
SS5Y5-51F 12- Stations D- CKC::, N, :
KN:
: D side U side
(Light/surge voltage suppressor) Manual override

50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
2 x M2.6 4(A) port side : Blue (For rubber seal)
16 24.1 : Gray (For metal seal)
2 x 4-40 UNC
2(B) port side : Yellow
[For N or T thread] (7.9)
4 x ø4.5
(For mounting)
B A B A B A B A B A

106.2
14 A 14 A 14 A 14 A 14 A

116.6
81.6

30.2 20
52.2
12 B 12 B 12 B 12 B 12 B

(Max. 3) L1

6.1 (Station 1) ------ (Station n)

manual override)
(Slide locking
(74.7)

74.3
68.6
60.7

38
Panel fitting dimensions

(4.9)
(Pitch)
2 x ø4.5 50 P = 16
25.2

(For 9 stations or more) 24 2 x M4 x 0.7 One-touch fitting


5

4 x M4 x 0.7, thread depth 5 (For 9 stations or more)


4 x ø4.5 [4(A), 2(B) port]
(For mounting)
Applicable tube O.D.: ø4, ø5/32"
61.6
71.6

40.2

3EB 2B 2B : ø6, ø1/4"


20

: ø8, ø5/16"
20 20

71.6
4 x M4 x 0.7 1P

4 x ø4.5
5EA 4A 4A
5 5
Fitting dimensions for panel mounting
L3 1/4
C4, C6 : 14.8
: 17.2

Refer to panel fitting dimensions for details.


L2 [1(P), 5(EA), 3(EB) port]
L3
L2
C8

Port size 01 Port size 02 One-touch fitting (Replaceable)


: These figures show the “SS5Y5-
51F2-05D-C8”.
38

38

38
(15.5)

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5
14.8

14.5

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C:, N:, KC:, KN:


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

59
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Valve
Dimensions: Series SY7000 Metal Base D-sub Connector

02
SS5Y7-51F 12 - Stations D- CKC::, N, :
KN:
:(D) D side U side
Manual override

Sub-plate
(Light/surge voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent 52
(Pitch)
P = 19 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
16 24.1
2(B) port side: Yellow

Plug-in
(23.9)

4 x ø4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
32.1 24
62.6
(Connector entry upward direction)
12 B 12 B 12 B 12 B 12 B

NC
NC
2 x M2.6

Metal Base
2 x 4-40 UNC
[For N or T thread]

6.1 (Station 1) (Station n)

manual override)
(Slide locking

Plug-in
(81.2)

78.3
84
67.2

44.5

(5.4)

Manifold Exploded View


Type 50, 51, 52
(Pitch) 3/8
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]
M4 x 0.7 thread depth 5
4 x M4 x 0.7 thread depth 5
(For 9 stations or more)
(For mounting) 27
Fitting dimensions for
panel mounting
5

Refer to panel fitting

22 33.1
46.1

Connector Connecting Base


Port size 02 One-touch fitting (Replaceable) 3EB 2B 2B
dimensions for details.
23 23
81.1

1P
(For ø12)

5EA 4A 4A
(29.5)

One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : ø8
C10: ø10
5 L2 N9 : ø5/16"
L1 N11: ø3/8"
(17.6)

Plug-in

: These figures show the “SS5Y7-51F2-05D-C10”.

Manifold Exploded View


Type 10, 11, 12
One-touch fitting
[4(A), 2(B) port] Panel fitting dimensions
Applicable tube O.D.: ø6, ø1/4"
1/4" : ø8, ø5/16" 4 x ø4.5 2 x ø4.5
: ø10, ø3/8" (For 9 stations or more)
5

[4(A), 2(B) port]


: ø12
24 27.1
32.8
22 33.1

3EB 2B 3EB 2B
81.1
72.1

Plug Assembly Part No.


One-touch Fittings/

1P 1P

4 x M4 x 0.7
22.6

5EA 4A 5EA 4A 5 5 4 x ø4.5


L3
L2
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
60
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P M5, 01
SS5Y3-51 PG 1
PH 2 - Stations D- C:, N: :
KC:, KN:
D side
Manual override
U side
J
(Light/surge voltage suppressor)
Applicable connector: (Pitch)
Push-turn locking slotted type:
Press, then rotate it. ( )
45.1 P = 10.5 4(A) port side : Blue (For rubber seal)
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) 14 24.1 : Gray (For metal seal)
2(B) port side : Yellow
(9.9)
51PJG (20 pins) 51PH (10 pins) 4 x ø4.5
(For mounting)
Triangle Triangle B A B A B A B A B A

92.7
16

89
14 A 14 A 14 A 14 A 14 A

For PC wiring mark mark

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Connector entry
PCW type

upward direction)
(Max. 3) L1
(Station 1)---(Station n)

manual override)
Applicable connector: Applicable connector: 18

(Slide locking
20 pins MIL type with strain relief 10 pins MIL type with strain relief

(80.6)

68.3
62.6
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

56.7

32
Panel fitting dimensions

(4.1)
(For 9 stations or more)

(Pitch)
46.4 P = 10.5 One-touch fitting
2 x ø4.5 23.6 [4(A), 2(B) port]
4

(For 9 stations or more) Applicable tube O.D.: ø2


4 x M4 x 0.7, thread depth 4
40 : ø3.2, ø1/8"
(For mounting)
17.8

21.1
16.8

(For 9 stations or more) : ø4, ø5/32"


4 x ø4.5 : ø6, ø1/4"
29.8

3EB 2B 2B
52.4
56.4
16

56.4
1P

4 x M4 x 0.7 5EA 4A 4A
16.8

4 x ø4.5
4 4 Fitting dimensions for panel mounting
C2, C3, C4 : 16
: 15
1/8 Refer to panel fitting dimensions for details.
L3 [1(P), 5(EA), 3(EB) port] L3
L2 2 x M4 x 0.7
(For 9 stations or more) L2
C6

Port size M5 Port size 01 One-touch fitting (Replaceable)


: These figures show the “SS5Y3-
51P2-05D-C6”.
32

32

32

(Pitch) (Pitch) (Pitch)


20.1

21.1

20.1
)

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


C6: 12.8
N7: 16.6
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P
(

5EA 4A 5EA 4A 5EA 4A


14

One-touch fitting
M5 x 0.8 1/8
[4(A), 2(B) port]
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

Port Size M5, C:, N:, KC:, KN:


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

61
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Valve
Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P 01, 02
SS5Y5-51 PG 1
PH 2 - Stations D- C:, N: :
KC:, KN:
D side U side
Manual override
J
Applicable connector: (Light/surge voltage suppressor)
(
Push-turn locking slotted type:
)

Sub-plate
26 pins MIL type with strain relief Press, then rotate it.
(Pitch)
(Conforming to MIL-C-83503) 4(A) port side : Blue (For rubber seal)
50 P = 16
: Gray (For metal seal)
Triangle mark 16 24.1 2(B) port side : Yellow
(9.9)

Plug-in
4 x ø4.5
(For mounting)
B A B A B A B A B A

106.2
14 A 14 A 14 A 14 A 14 A

116.6
51PJG (20 pins) 51PH (10 pins)

81.6

30.2 20
52.2
For PC wiring Triangle mark Triangle mark 12 B 12 B 12 B 12 B 12 B

(Max. 3) L1
(Connector entry

Metal Base
PCW type

upward direction) (Station 1) ------ (Station n)


18

manual override)
(Slide locking
(86.6)

74.3
68.6
62.7

Plug-in
Applicable connector: Applicable connector:

38
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

(4.9)
(Pitch)
50 P = 16

Manifold Exploded View


Panel fitting dimensions 2 x M4 x 0.7

Type 50, 51, 52


(For 9 stations or more)
24 One-touch fitting
2 x ø4.5 4 x M4 x 0.7, thread depth 5 [4(A), 2(B) port]
25.2

(For 9 stations or more) (For mounting) Applicable tube O.D.: ø4, ø5/32"
5

4 x ø4.5 : ø6, ø1/4"


40.2

3EB 2B 2B
: ø8, ø5/16"
20 20

71.6
61.6
71.6
20

1P

4 x M4 x 0.7 5EA 4A 4A

4 x ø4.5 Fitting dimensions for panel mounting

Connector Connecting Base


5 5 1/4
C4, C6 : 14.8
L3 : 17.2 Refer to panel fitting dimensions for details.
[1(P), 5(EA), 3(EB) port]
L2 L3
L2
C8

Port size 01 Port size 02 One-touch fitting (Replaceable)



: These figures show the “SS5Y5-
51P2-05D-C8”.

Plug-in
38

38

38

(Pitch) (Pitch) (Pitch)

Manifold Exploded View


(15.5)

50 P = 16 50 P = 17.5 50 P = 16
Type 10, 11, 12
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A
5EA 4A

1/8 1/4 One-touch fitting


Plug Assembly Part No.

[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]


One-touch Fittings/

Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C:, N:, KC:, KN:


n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

62
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY7000 Metal Base Flat Ribbon Cable

P 02
SS5Y7-51 PG 1
PH 2 - Stations D- C:, N: :(D)
KC:, KN:
D side U side
J Manual override
(Light/surge voltage suppressor)
(Pitch)
( Push-turn locking slotted type:
Press, then rotate it. )
52 P = 19 4(A) port side: Blue (For rubber seal)
Applicable connector: : Gray (For metal seal)
16 24.1
Triangle mark 26 pins MIL type with strain relief 2(B) port side: Yellow
(25.9)
(Conforming to MIL-C-83503)

4 x ø4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
32.1 24
62.6
(Connector entry upward direction)
12 B 12 B 12 B 12 B 12 B

NC
NC
18 (Station 1) (Station n)
50PJG (20 pins) 51PH (10 pins)
Triangle mark

manual override)
Triangle mark

(Slide locking
For PC wiring

(93.1)

78.3
84
69.2

44.5
PCW type

(5.4)
4 x M4 x 0.7 thread depth 5
(For mounting) 3/8
(Pitch)
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]

Applicable connector: Applicable connector: M4 x 0.7 thread depth 5


20 pins MIL type with strain relief 10 pins MIL type with strain relief 27 (For 9 stations or more)
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) Fitting dimensions for
panel mounting
5

Refer to panel fitting

22 33.1
dimensions for details.
46.1

2B 2B
Port size 02 One-touch fitting (Replaceable) 3EB
23 23
81.1

1P

5EA 4A 4A
(For ø12)
(29.5)

One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : ø8
C10: ø10
5 L2 N9 : ø5/16"
L1
(17.6)

N11: ø3/8"

One-touch fitting
: These figures show the “SS5Y7-51P2-05D-C10”.
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16" Panel fitting dimensions
: ø10, ø3/8"
: ø12
4 x ø4.5 2 x ø4.5
1/4
(For 9 stations or more)
[4(A), 2(B) port]
5

24 27.1
32.8
22 33.1

3EB 2B 3EB 2B
81.1
72.1

1P 1P

4 x M4 x 0.7
22.6

5EA 4A 5EA 4A
5 5 4 x ø4.5
L3
L2

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136

63
64
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Metal Base
D-sub Connector Flat Ribbon Cable PC Wiring
Type 52
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 52 F 1 05 D
/ 4 ) 0 1 6 2 * -
/ Series 4 Type ) Connector type
3 SY3000 52 Top ported F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 52R Top ported, External pilot (25 pins) (26 pins) (20 pins)
7 SY7000

0 Connector entry direction


1: Upward 2: Lateral

PH: Flat ribbon cable J: PC wiring


(10 pins) (20 pins)

1 Wiring type
Nil All double wiring
1
S All single wiring
2
6 Valve stations

1: All double wiring: 2-position single, double, 3-position and 4-position


valves can be used on all manifold stations. F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)

2: All single wiring: Available only for the manifold which has 2-position Symbol Stations Note Symbol Stations Note Symbol Stations Note
single for all stations. 02 2 stations 02 2 stations 02 2 stations
All All All
Note that 2-position double, 3- or 4-position valves cannot be used.

: If a mix of single and double wiring is required, it is supplied as a double double double
special order. 12 12 stations wiring 12 12 stations wiring 09 9 stations wiring
02 2 stations All 02 2 stations All 02 2 stations All
How to Order Manifold Assembly single single single
12 12 stations wiring 12 12 stations wiring 12 12 stations wiring

Example (SS5Y3-52F2-:) PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
2-position double (24 VDC) Symbol Stations Note Symbol Stations Note
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) SY3230-5U1-C6 (1 set) 02 2 stations All 02 2 stations All
3-position closed double double
center (24 VDC) 04 4 stations wiring 08 8 stations wiring
SY3330-5U1-C6 (1 set) 02 2 stations 02 2 stations
All All
single single
08 8 stations wiring 12 12 stations wiring

: This also includes the number of blanking plate assembly.

Us
ide 2 P, E port entry * Thread type
ions U U side
1 Nil Rc
tat D side
1 00F
S D G
Manifold base 3 B Both sides 00N NPT
2
(5 stations) 1 00T NPTF
ide

1: Plugs are mounted on the opposite
SS5Y3-52F2-05D Ds side of the selected ports.

SS5Y3-52F2-05D ········· 1 set (Type 52 5-station manifold base part no.)



SY3130-5U1-C6 ··········· 3 sets (2-position single part no.)
- Mounting

SY3230-5U1-C6 ··········· 1 set (2-position double part no.) Nil Direct mounting

SY3330-5U1-C6 ··········· 1 set (3-position closed center part no.) D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc. D3 For 3 stations
Specify a longer rail than
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE the standard length.
D12 For 12 stations
sUnder the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
: Refer to page 271 for the fixation of DIN rail
becomes complicated, specify on a manifold specification sheet. mounting type manifold.

65
Plug-in Metal Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 2 Coil type  A, B port size
3 SY3000 Nil Standard Thread piping
5 SY5000 With power saving circuit Symbol Port size Applicable series
T
7 SY7000 (Continuous duty type) M5 M5 x 0.8 SY3000

: Be sure to select the power saving circuit 01 1/8 SY5000
type when a valve is continuously energized 02 1/4 SY7000
4 Type of actuation for long periods of time.

Metal Base
1 Single
: Be careful of the energizing time when the One-touch fitting (Metric)
2-position power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed center 268 for details. C2 ø2 ) — —
4 3-position Exhaust center C3 ø3.2 ) — —
C4 ø4 ) ) —
5 Pressure center * Rated voltage

Plug-in
A
1 4-position N.C./N.C. C6 ø6 ) ) )
5 24 VDC
B
1 dual N.O./N.O. C8 ø8 — ) )
6 12 VDC
C
1 3-port N.C./N.O. C10 ø10 — — )

1: Only rubber seal type is available for


C12 ø12 — — )
the 4-position dual 3-port valve. - Light/surge voltage suppressor One-touch fitting (Inch)

Manifold Exploded View


and common specification Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


) Seal type Surge voltage Common N1 ø1/8" ) — —
Symbol With light
suppressor specification N3 ø5/32" ) ) —
0 Rubber seal
Nil — — N7 ø1/4" ) ) )
1 Metal seal
R — Non-polar N9 ø5/16" — ) )
U ) N11 ø3/8" — — )
0 Pilot type S —
)
Positive
common
Nil Internal pilot Z )
 Thread type

Connector Connecting Base


R External pilot NS — Negative
NZ ) common Nil Rc

: Only “Z” and “NZ” types are available for with F G
1 Back pressure check valve the power saving circuit. N NPT
(Built-in valve type) T NPTF
Nil
: Only Nil is available for M5.
H
None
Built-in
 Manual override
Nil: D:

: Only rubber seal type

: Back pressure check valve is not Non-locking Push-turn  Type of mounting screw
push type locking Nil Round head combination screw

Plug-in
available for the 3-position type and the
SY7000. slotted B Hexagon socket head cap screw
type K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type)

Manifold Exploded View


6 Pilot valve option
: For “K” and “H”, the valve body cover has a Type 10, 11, 12
Nil Standard (0.7 MPa) drop prevention construction to stop the
B Quick response type (0.7 MPa) E: F: mounting screws from falling out when the
Push-turn Slide locking valve is removed for maintenance etc.
K
1 High pressure type (1.0 MPa)
locking lever type
: When ordering a valve individually, the

1: Only metal seal type is available for type base gasket is not included.
the high pressure type. Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service.
Plug Assembly Part No.

Refer to page 89 for part numbers of the


One-touch Fittings/


: Refer to page 31 for with the safety slide
base gasket and mounting screw.
locking manual override.

: “B” and “H” cannot be selected for the individual
SUP/EXH spacer assembly or interface regulator.
Manifold Options

Protective class
class  (Mark: )
66
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY3000 Metal Base D-sub Connector, Flat Ribbon Cable

F
P 1 U
SS5Y3-52(R) PG
PH 2
- Stations D -:(D)
B
J
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (Pitch) Manual override

68.3
DIN rail holding screw
(For DIN rail mounting)
45.1
14 24.1
P = 10.5
(
Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge 4(A) port side : Blue (For rubber seal)
(Slide locking manual override) (7.9) voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting)

DIN rail

5.5
(Connector entry B A B A B A B A B A

upward direction)

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
15.9 16.2
79
64.4

56.9
21.8 16
1P

2 x M2.6

11
32.1
35
29.8

35
X

26.6
2B 2B 2B 2B 2B
3EB

2 x 4-40 UNC
[For N or T thread]
8.6 4 x ø4.5
One-touch fitting
8
14.5 (For mounting) 4 L2
M5 x 0.8 (External pilot) [4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
[External pilot port]
28 : ø3.2, ø1/8"
1/8 M5 x 0.8
: ø4, ø5/32"
[1(P), 5(EA), 3(EB) port] [4(A), 2(B) port] : ø6, ø1/4"
(Station 1)---(Station n)
6.1
F
52R PJ: 12 - Stations U
D

)C6: 76.8
N7: 80.6
(68.7)
62.6
54.7

3
[Plug for external pilot]
(
32

(For DIN rail


7.5

mounting)
11.8


: The above drawing shows when P,
E port entry is D.


: These figures show the “SS5Y3-52F2-05B”.

52P (26 pins) 52PJG (20 pins) 52PH (10 pins)


For PC wiring
Triangle mark Triangle mark Triangle mark
14 (9.9) 14 (9.9) 14 (9.9)

B A B A B A
4A 4A 4A
5EA

5EA

5EA
PE

PE

PE
PCW type
1P

1P

1P
X

2B 2B 2B
3EB

3EB

3EB

Applicable connector: Applicable connector: Applicable connector:


26 pins MIL type with strain relief 20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

67
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Valve
Dimensions: Series SY5000 Metal Base D-sub Connector, Flat Ribbon Cable

F
P 1 U
SS5Y5-52(R) PG
PH 2
- Stations D -:(D) D side U side
B L3
J Manual override

Sub-plate
5.3 L4
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) (DIN rail mounting hole pitch: 12.5) (
Push-turn locking slotted type:
Press, then rotate it. )
74.3 (Pitch) 4(A) port side : Blue (For rubber seal)
DIN rail holding screw 50 P = 16 (Light/surge : Gray (For metal seal)
(Slide locking manual override)
voltage

Plug-in
68.6 (For DIN rail mounting) 16 24.1 2(B) port side : Yellow
M5 x 0.8 (External pilot) suppressor)
DIN rail bracket mounting screw (7.9)
[Pilot EXH port]

01 : 16.2
C:: 14.5
(For DIN rail mounting)
DIN rail
(Connector entry B A B A B A B A B A
4A 4A 4A 4A 4A
PE
5EA

upward direction)

106.2
5.5
23.2

116.6
96.2

20

35
81.6

74.1
20
1P

Metal Base
24.6
20

52.2

43.8
40.2

40.2
2 x M2.6
3EB

30.2 8
X

2B 2B 2B 2B 2B
2 x 4-40 UNC
[For N or T thread]
12.3 1/8

Plug-in
18 M5 x 0.8 (External pilot) 4 x ø4.5 One-touch fitting
[4(A), 2(B) port]
[External pilot port] (For mounting) [4(A), 2(B) port]
28 5 L2
1/4 Applicable tube O.D.: ø4, ø5/32"
34 (L5) L1 : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port]
: ø8, ø5/16"

52P (26 pins) (Station 1)----------- (Station n)

Manifold Exploded View


Type 50, 51, 52
6.1
Triangle mark 16 (9.9)

(86.7)
(74.7)
72.3
60.7

B A
4A
PE
5EA

38

Connector Connecting Base


1P
3EB

(For DIN rail


X

10

mounting)
2B
14.3

Applicable connector:
: These figures show the “SS5Y5-52F2-05B”.
26 pins MIL type with strain relief
(Conforming to MIL-C-83503)

Plug-in
F
52PJG (20 pins) 52PH (10 pins) 52R PJ: 12 - Stations UD
For PC wiring
16 (9.9) Triangle mark 16 (9.9)

Manifold Exploded View


Triangle mark
Type 10, 11, 12
3
[Plug for external pilot]
B A B A
4A 4A
PE

PE
5EA

5EA
PCW type
1P

1P

Plug Assembly Part No.


3EB

3EB
X

One-touch Fittings/

2B 2B

: The above drawing shows when P,
E port entry is D.

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

68
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY7000 Metal Base D-sub Connector, Flat Ribbon Cable
F
1 Stations P U
SS5Y7-52(R) PG
PH 2
- D -:(D) D side
L3 U side
B
J 5.3 L4
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (DIN rail mounting hole pitch: 12.5)
Manual override

84
DIN rail holding screw 52
P = 19
(Pitch)
(Push-turn locking slotted type:
Press, then rotate it. )
(Slide locking manual override) 16 24.1 4(A) port side: Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage
M5 x 0.8 (External pilot) 78.3 suppressor) : Gray (For metal seal)
(7.9) 2(B) port side: Yellow
PE: Pilot EXH port
DIN rail bracket mounting screw
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A

5.5
PE

4A 4A 4A 4A 4A
5EA

116.7
23.8
28

35
102.1

133.2
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
45.6
44.1

22.6
3EB

8
X

32.1
2 x M2.6 2B 2B 2B 2B 2B
2 x 4-40 UNC

NC
NC
[For N or T thread]
18.1 4 x ø4.5 1/4
20.9 (For mounting) [1(A), 2(B) port]
One-touch fitting
34.5 M5 x 0.8 (External pilot) 5 L2
[4(A), 2(B) port]
40.5 X: External pilot port (L5) L1 Applicable tube O.D.: ø6, ø1/4"
3/8
(Connector entry upward direction) : ø8, ø5/16"
[1(P), 5(EA), 3(EB) port] : ø10, ø3/8"
: ø12
(Station 1) (Station n)
52P (26 pins)
Triangle mark 16 (9.9) 6.1

(A, B port: ø12)


(110.3)
(98.4)
B A
(81.2)
87
PE

4A
5EA

67.2

44.5
1P
3EB
X

2B
(For DIN rail
mounting)
10

14.3

Applicable connector:
26 pins MIL type with strain relief
:These figures show the “SS5Y7-52F2-05B”.
(Conforming to MIL-C-83503)
F
52PJG (20 pins) 52PH (10 pins) 52R PJ: 12 - Stations UD
For PC wiring Triangle mark 16 (9.9) Triangle mark 16 (9.9)

3
[Plug for external pilot]
B A B A
PE

PE

4A 4A
PCW type
5EA

5EA
1P

1P
3EB

3EB
X

2B 2B


: The above drawing shows when P,
E port entry is D.
Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
69
Plug-in Metal Base Series SY3000/5000/7000

Valve
Electrical Wiring Specifications Cable Assembly
015
D-sub connector
AXT100-DS25- 030 (N) [IP40 compliant]
050

Sub-plate
Nil: Metric size
Lead wire color for
N: Inch size D-sub connector
1
cable assembly by
14 2 terminal number
15 3 Cable Lead

Plug-in
16 Terminal Dot
4 0.3 mm2 x 25 cores wire
17 no. color marking
5 O.D. ø1.4
18 6 1 Black None
19 Approx. ø10
7 2 Brown None
20 8
21 9 3 Red None
22 Connector terminal no. Seal (Length)
10 015 4 Orange None
23 11
24 5 Yellow None
12

L
25 13 Molded cover 6 Pink None

Metal Base
7 Blue None
2 x M2.6 x 0.45

44
or 2 x 4-40 UNC 8 Purple White
Connector JBZ-25S-3 9 Gray Black
<All single wiring> <All double wiring>

8
made by J.S.T. Mfg. 10 White Black
Terminal no. Terminal no. Polarity Co., Ltd.
11 White Red

(2.4)

Plug-in
SOL.a SOL.a 55 12 Yellow Red
Station 1 1 1 (–) (+) Socket side
SOL.a Station 1 SOL.b 13 Orange Red
Station 2 14 14 (–) (+) 14 25
SOL.a SOL.a 14 Yellow Black
Station 3 2 2 (–) (+) Terminal no.
SOL.a Station 2 SOL.b 16 15 Pink Black
Station 4 15 15 (–) (+)
SOL.a SOL.a 16 Blue White
Station 5 3 3 (–) (+) 1 13

Manifold Exploded View


SOL.a Station 3 SOL.b 47.04 17 Purple None
Station 6 16 16 (–) (+)

Type 50, 51, 52


SOL.a 4 SOL.a 18 Gray None
Station 7 4 (–) (+)
SOL.a Station 4 SOL.b 19 Orange Black
Station 8 17 17 (–) (+)
SOL.a 5 SOL.a 20 Red White
Station 9 5 (–) (+)
SOL.a Station 5 SOL.b 21 Brown White
Station 10 18 18 (–) (+)
SOL.a SOL.a D-sub connector cable assembly 22 Pink Red
Station 11 6 6 (–) (+)
SOL.a Station 6 SOL.b Cable 23 Gray Red
Station 12 19 19 (–) (+) Assembly part no. Note
SOL.a length (L) 24 Black White
7 7 (–) (+)
Station 7 SOL.b 1.5 m AXT100-DS25-015 25 White None
20 20 (–) (+)

Connector Connecting Base


Cable
8 SOL.a 3m AXT100-DS25-030 0.3 mm2 x 25 cores
8 (–) (+)
Station 8 SOL.b 5m AXT100-DS25-050
21 21 (–) (+)
SOL.a
When using a standard commercial
9 9 (–) (+)
Station 9 SOL.b connector, use a 25-pin type female
22 22 (–) (+) connector conforming to MIL-C-24308.
SOL.a
10 10 (–) (+)
Cannot be used for movable wiring.
Station 10 SOL.b
23 23 (–) (+)
Lengths other than the above are also
11 SOL.a available. Please contact SMC for details.
11 (–) (+)
Station 11 SOL.b
24 24 (–) (+)
12 SOL.a Electrical characteristics Connector Manufacturers’ Example

Plug-in
12 (–) (+)
Station 12 SOL.b Item Property
25 25 (–) (+) s&UJITSU,IMITED
Conductor resistance sJapan Aviation Electronics Industry, Limited
7/km, 20nC 65 or less
COM. s*34-FG#O ,TD

Manifold Exploded View


COM. 13 13 (+) (–) s()2/3%%,%#42)##/ ,4$
Voltage limit
Positive Negative V, 1 minute, AC 1000 Type 10, 11, 12
common common
Insulation resistance
M7/km, 20nC 5 or more

: When using a valve with no polarity, either positive common or negative


common can be used.
: The minimum bending
radius of the D-sub
connector cable is 20 mm.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

70
Series SY3000/5000/7000

Electrical Wiring Specifications Cable Assembly


10 1
Flat ribbon cable connector AXT100-FC 20 -2
26 3
26 25
24 23
6 Terminal no. 28AWG
Red
22 21
20 19

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
18 17
16 15
14 13
12 11 Connector terminal no.
10 9

26

25
8 7
Triangle mark indicator position (15.6)
6 5
4 3 L
2 1
Flat ribbon cable connector assembly
Cable Assembly part no.
P: Flat ribbon cable (26 pins) length (L) 26 pins 20 pins 10 pins
<All single wiring> <All double wiring> 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
Terminal no. Terminal no. Polarity 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
SOL.a 1 SOL.a (–) (+) AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
Station 1 1 5m
Station 2
SOL.a 2 Station 1 SOL.b 2 (–) (+)
When using a standard commercial connector, use a 26-pin, 20-pin or
SOL.a 3 SOL.a 3 (–) (+)
Station 3 10-pin type connector conforming to MIL-C-83503 with strain relief.
Station 4
SOL.a 4 Station 2 SOL.b 4 (–) (+)
Cannot be used for movable wiring.
Station 5 SOL.a 5 SOL.a 5 (–) (+)
Lengths other than the above are also available. Please contact SMC
Station 6
SOL.a 6 Station 3 SOL.b 6 (–) (+) for details.
Station 7 SOL.a 7 SOL.a 7 (–) (+)
Station 8 SOL.a 8 Station 4 SOL.b 8 (–) (+) Connector Manufacturers’ Example
Station 9 SOL.a 9 SOL.a 9 (–) (+)
Station 10 SOL.a 10 Station 5 SOL.b 10 (–) (+) sHIROSE ELECTRIC CO., LTD. sJapan Aviation Electronics Industry, Limited
Station 11 SOL.a 11 SOL.a 11 (–) (+) s-*APAN,IMITED s*34-FG#O ,TD
Station 12 SOL.a 12 Station 6 SOL.b 12 (–) (+) s&UJITSU,IMITED s/KI%LECTRIC#ABLE#O ,TD
13 SOL.a 13 (–) (+)
Station 7 SOL.b 14
14 (–) (+)
15 SOL.a 15 (–) (+) PH: Flat ribbon cable (10 pins)
Station 8 SOL.b 16
16 (–) (+) <All single wiring> <All double wiring>
17 SOL.a 17 (–) (+)
Station 9 SOL.b 18 Terminal no. Terminal no. Polarity
18 (–) (+) SOL.a SOL.a
19 SOL.a 19 (–) (+) Station 1 1 1 (–) (+)
Station 10 SOL.a Station 1 SOL.b
SOL.b 20 (–) (+) Station 2 2 2 (–) (+)
20 SOL.a SOL.a
SOL.a 21 (–) (+) Station 3 3 3 (–) (+)
21 SOL.a Station 2 SOL.b
Station 11 SOL.b 22 Station 4 4 4 (–) (+)
22 (–) (+) SOL.a SOL.a
23 SOL.a 23 (–) (+) Station 5 5 5 (–) (+)
Station 12 SOL.a Station 3 SOL.b
24 SOL.b 24 (–) (+) Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
COM. COM. 7
25 25 (+) (–) SOL.a Station 4 SOL.b
COM. 26 COM. Station 8 8 8 (–) (+)
26 (+) (–) COM. COM.
9 9 (+) (–)
Positive Negative COM. 10 COM.
10 (+) (–)
common common
Positive Negative
common common
PG: Flat ribbon cable (20 pins)
<All single wiring> <All double wiring> J: Flat ribbon cable (20 pins) PC wiring
Terminal no. Terminal no. Polarity
SOL.a SOL.a <All single wiring> <All double wiring>
Station 1 1 1 (–) (+)
SOL.a Station 1 SOL.b Terminal no. Terminal no. Polarity
Station 2 2 2 (–) (+)
SOL.a SOL.a (–) (+) SOL.a 20 SOL.a 20 (–) (+)
Station 3 3 3 Station 1
SOL.a Station 2 SOL.b SOL.a Station 1 SOL.b 18
Station 4 4 4 (–) (+) Station 2 18 (–) (+)
Station 5 SOL.a SOL.a 5 (–) (+) SOL.a SOL.a 16 (–) (+)
5 Station 3 16
SOL.a Station 3 SOL.b SOL.a Station 2 SOL.b 14
Station 6 6 6 (–) (+) Station 4 14 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+) Station 5 SOL.a SOL.a 12
7 12 (–) (+)
SOL.a Station 4 SOL.b SOL.a Station 3 SOL.b 10
Station 8 8 8 (–) (+) Station 6 10 (–) (+)
Station 9 SOL.a SOL.a 9 (–) (+) Station 7 SOL.a SOL.a
9 8 8 (–) (+)
SOL.a Station 5 SOL.b 10 SOL.a Station 4 SOL.b
Station 10 10 (–) (+) Station 8 6 6 (–) (+)
Station 11 SOL.a SOL.a 11 (–) (+) Station 9 SOL.a SOL.a
11 19 19 (–) (+)
SOL.a Station 6 SOL.b 12 SOL.a 17 Station 5 SOL.b
Station 12 12 (–) (+) Station 10 17 (–) (+)
SOL.a 13 (–) (+) Station 11 SOL.a 15 SOL.a
13 15 (–) (+)
Station 7 SOL.b 14 SOL.a 13 Station 6 SOL.b
14 (–) (+) Station 12 13 (–) (+)
SOL.a 15 (–) (+) 11 SOL.a
15 11 (–) (+)
Station 8 SOL.b 16 Station 7 SOL.b
16 (–) (+) 9 9 (–) (+)
SOL.a 17 (–) (+) 7 SOL.a
17 7 (–) (+)
Station 9 SOL.b 18 Station 8 SOL.b
18 (–) (+) 5 5 (–) (+)
COM. 19 COM. 4 4
19 (+) (–)
COM. 20 COM. 3 3
20 (+) (–)
COM. 2 COM. 2 (+) (–)
Positive Negative
common common COM. 1 COM. 1 (+) (–)
Positive Negative

: When using a valve with no polarity, either positive common or negative common common
common can be used.

71
72
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 50
Side Ported Plug-in Metal Base EX510

Series SY3000/5000/7000
Type 51
Bottom Ported

How to Order Manifold

SS5Y 3 50 S5 05 D C6
/ 4 ) 0 1 6 2 * -
/ Series 4 Type 1 Valve stations
3 SY3000 50 Side ported Symbol Stations Note Symbol Stations Note
5 SY5000 51 Bottom ported 02 2 stations 02 2 stations
All double All single
7 SY7000 50R Side ported, External pilot
wiring wiring

: External pilot is not available 08 8 stations 12 12 stations
) SI Unit output polarity for the bottom ported type.
: This also includes the number of blanking plate assembly.
Nil Positive common
N Negative common 6 P, E port entry
U U side
1
1: Plugs are mounted on the opposite
side of the selected ports.
D D side
1
2
0 Wiring type B Both sides

2: Only D side is available for Type 51
Nil All double wiring
1 (Bottom ported).
S All single wiring
2 2 A, B port size

1: All double wiring: 2-position single, double, 3-position and 4-position Thread piping
valves can be used on all manifold stations.

2: All single wiring: Available only for the manifold which has 2-position
Symbol A, B port SY3000 SY5000 SY7000
single for all stations. M5 M5 x 0.8 ) — —
Note that 2-position double, 3- or 4-position valves cannot be used. 01 1/8 ) ) —

: If a mix of single and double wiring is required, it is supplied as a 02 1/4 — ) )


special order. One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
C2 ø2 ) — —
C3 ø3.2 ) — —
How to Order Manifold Assembly
Fixed

C4 ø4 ) ) —
C6 ø6 ) ) —
Example (SS5Y3-50S5-:) C8 ø8 — ) )
2-position single (24 VDC) 2-position double (24 VDC)
C10 ø10 — — )
SY3100-5U1 (3 sets) SY3200-5U1 (1 set)
3-position closed KC2 ø2 ) — — Type 50 Type 51
center (24 VDC) (Side ported) (Bottom ported)
KC3 ø3.2 ) — —
SY3300-5U1 (1 set)
KC4
Replaceable

ø4 ) ) —
KC6 ø6 ) ) )
KC8 ø8 — ) )
KC10 ø10 — — )
KC12 ø12 — — )
ide M
1 Mixed sizes ) ) )
Us
P, E port size (Thread piping) 1/8 1/4 3/8
s
n
tio
ta
S

One-touch fitting (Inch)


3
Manifold base 2 Symbol A, B port SY3000 SY5000 SY7000
1
(5 stations) ide
Ds N1 ø1/8" ) — —
SS5Y3-50S5-05D-C6
N3 ø5/32" ) ) —
Fixed

SS5Y3-50S5-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.)


N7 ø1/4" ) ) —

SY3100-5U1 ················· 3 sets (2-position single part no.)

SY3200-5U1 ················· 1 set (2-position double part no.) N9 ø5/16" — ) )

SY3300-5U1 ················· 1 set (3-position closed center part no.) N11 ø3/8" — — )
The asterisk denotes the symbol for assembly. KN1 ø1/8" ) — — Type 50 Type 51
Prefix it to the part numbers of the valve etc. (Side ported) (Bottom ported)
KN3 )
Replaceable

ø5/32" ) —
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
KN7 ø1/4" ) ) )
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement KN9 ø5/16" — ) )
becomes complicated, specify on a manifold specification sheet. KN11 ø3/8" — — )

: When mixing top ported configurations, select from page 84. M


1 Mixed sizes ) ) )
In this case, use caution as there is also output on the A and B port on base side.
P, E port size (Thread piping) 1/8 1/4 3/8
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.
1: When ports are mixed sizes, indicate the piping specifications on the manifold specification sheet.
73
Plug-in Metal Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
* Thread type - Mounting
Nil Rc Nil Direct mounting
F G DIN rail mounting
D (With DIN rail)
N NPT For details about the EX510 Gateway-type
T NPTF DIN rail mounting Serial Transmission System, refer to the
D0

Metal Base
(Without DIN rail) WEB catalog or the Best Pneumatics No. 1
D3 For 3 stations and the Operation Manual. Please download
Specify a longer rail than
the Operation Manual via SMC website,
the standard length.
D12 For 12 stations http://www.smcworld.com

: Only direct mounting is available for Type 51

Plug-in
(Bottom ported).

: Refer to page 271 for the fixation of DIN rail
mounting type manifold.

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

Manifold Exploded View


Type 50, 51, 52
SY 3 1 0 0 5 1
 Manual override
/ 4 ) 0 1 6 2 * -   Nil: D:
Non-locking Push-turn
Base mounted push type locking
slotted

Connector Connecting Base


/ Series 6 Pilot valve option type
3 SY3000 Nil Standard (0.7 MPa)
5 SY5000 B Quick response type (0.7 MPa)
7 SY7000 K
1 High pressure type (1.0 MPa)
E: F:

1: Only metal seal type is available for the
Push-turn Slide locking
high pressure type.
4 Type of actuation locking lever type
1 Single type
2
2-position
Double
2 Coil type

Plug-in
3 Closed center Nil Standard
4 3-position Exhaust center T With power saving circuit (Continuous duty type)
5 Pressure center
: Be sure to select the power saving circuit

: Refer to page 31 for with the safety slide

Manifold Exploded View


A
1 N.C./N.C. type when the valve is continuously
4-position energized for long periods of time. locking manual override. Type 10, 11, 12
B
1 dual 3-port
N.O./N.O.

: Be careful of the energizing time when the
C
1 N.C./N.O.
power saving circuit is selected. Refer to page

1: Only rubber seal type is available for the 268 for details.
 Type of mounting screw
4-position dual 3-port valve. Nil Round head combination screw
B Hexagon socket head cap screw
* Rated voltage K Round head combination screw (Falling-out-prevention type)
) Seal type 5 24 VDC H Hexagon socket head cap screw (Falling-out-prevention type)
0 Rubber seal
1 Metal seal
: For “K” and “H”, the valve body cover has a
- Light/surge voltage suppressor
Plug Assembly Part No.

drop prevention construction to stop the


One-touch Fittings/

and common specification mounting screws from falling out when the
0 Pilot type Surge voltage Common
valve is removed for maintenance etc.

: When ordering a valve individually, the
Nil Internal pilot Symbol With light
suppressor specification base gasket is not included.
R External pilot R — Since the base gasket is attached to the
Non-polar
U ) manifold, please order the base gasket
separately if it is needed for maintenance
1 Back pressure check valve S
Manifold Options


) Positive common service.
(Built-in valve type) Z )
Refer to page 89 for part numbers of the
Nil None NS — base gasket and mounting screw.
Negative common
H Built-in NZ )
: “B” and “H” cannot be selected for the

: Only “Z” and “NZ” types are available for with individual SUP/EXH spacer assembly,

: Only rubber seal type interface regulator or double check spacer

: Back pressure check valve is not available the power saving circuit. Select a valve from
R, U, S or Z when the SI Unit output polarity is assembly with residual pressure release valve.
for the 3-position type and the SY7000.
Nil (positive common).
Select a valve from R, U, NS or NZ when the Protective class
SI Unit output polarity is N (negative common). class  (Mark: )
74
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base EX510

U M5
SS5Y3-50(R)S5:- Stations D - KC
C:, N: :(D)
:, KN: B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override

M5 x 0.8 (External pilot) DIN rail holding screw


45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
18.5 19.6 (Light/surge 4(A) port side : Blue (For rubber seal)
[Pilot EXH port] (For DIN rail mounting)
voltage : Gray (For metal seal)
DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
(For DIN rail mounting)
DIN rail

B A B A B A B A B A

92.7
5EA

14 A 14 A 14 A 14 A 14 A

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 SI Unit 8


)Replaceable: 7.7

14.5 (For mounting)


4 L2
22.1 (L5) L1
Fixed: 4.1

28 M5 x 0.8 (External pilot)


[External pilot port]
1/8 (Station 1)---(Station n)
(

[1(P), 5(EA), 3(EB) port]

manual override)
(Slide locking
50RS5:- Stations UD

68.3
65.6

62.6
2B 2B

7.1

32
22.6
4A 4A

3
[Plug for external pilot]

(For DIN rail


2B

mounting)
C2, C3: 5.4 One-touch fitting

7.5
11.8
4A C4, C6: 6.6 [4(A), 2(B) port]
Applicable tube O.D.: ø2
C2, C3: 42.4 (Pitch) : ø3.2, ø1/8"
C4, C6: 41.8 P = 10.5 : ø4, ø5/32"

: The above drawing shows when P, : ø6, ø1/4"
E port entry is D.

: These figures show the “SS5Y3-50S5-05B-C6”.

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1
7.1

32

32
22.6

22.6

4A 4A

One-touch fitting
M5 x 0.8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø2
6.6 (Pitch)
(Pitch) : ø3.2, ø1/8"
41.8 P = 10.5 : ø4, ø5/32"
48.4 P = 10.5
: ø6, ø1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

75
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY3000 Metal Base EX510

U
SS5Y3-50(R)S5:- Stations D -01:(D)
B
D side U side

Sub-plate
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
M5 x 0.8 (External pilot)
[Pilot EXH port]
(Pitch)
(Push-turn locking slotted type:
)

Plug-in
45.1 P = 12.5 Press, then rotate it.
DIN rail holding screw
18.5 19.6 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage : Gray (For metal seal)
suppressor) 2(B) port side : Yellow
DIN rail bracket mounting screw
(For DIN rail mounting)

DIN rail
B A B A B A B A B A

92.7
5EA

14 A 14 A 14 A 14 A 14 A

89
PE
16.8 17.2
15.9 16.2
79

Metal Base
5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 SI Unit 8

Plug-in
14.5 (For mounting) 4 L2
22.1 M5 x 0.8 (External pilot) (L5) L1
28 [External pilot port]
1/8
[1(P), 5(EA), 3(EB) port]

Manifold Exploded View


(Station 1)------ (Station n)

Type 50, 51, 52


manual override)
(Slide locking
68.3
65.6

62.6
50RS5:- Stations UD 2B 2B 7.1

32
4A 4A
22.6

Connector Connecting Base


3

(For DIN rail


6.6

mounting)
[Plug for external pilot] (Pitch) 1/8
7.5
2B 41.8 P = 12.5 [4(A), 2(B) port] 11.8

4A


: The above drawing shows when P,
E port entry is D.
: These figures show the “SS5Y3-50S5-05B-01”.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

76
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base EX510

U 01
SS5Y5-50(R)S5:- Stations D - KC
C:, N: :(D)
:, KN: B
D side U side
L3
M5 x 0.8 (External pilot) 5.3 L4
Manual override
[Pilot EXH port] (DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail bracket mounting screw 20.5 19.6 (Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor) 2(B) port side : Yellow

DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20
81.6

74.1
20
1P
24.6
20

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B

4 x ø4.5
)
Replaceable: 8.5

12.3 SI Unit
(For mounting)
18 5 L2
Fixed: 4.9

28 (L5) L1
34 M5 x 0.8 (External pilot)
[External pilot port]
(

1/4
[1(P), 5(EA), 3(EB) port]
(Station 1)----------- (Station n)

50RS5:- Stations UD

manual override)
(Slide locking
74.3
71.6

68.6
3 2B 2B
7.8

[Plug for external pilot] 38


27.3

4A 4A
2B

4A
(For DIN rail
8.4
10

(Pitch) One-touch fitting mounting)


14.3

45.8 P = 16 [4(A), 2(B) port]



: The above drawing shows when P, Applicable tube O.D.: ø4, ø5/32"
E port entry is D. : ø6, ø1/4"
: ø8, ø5/16"


: These figures show the “SS5Y5-50S5-05B-C8”.

Port size 01 One-touch fitting (Replaceable)

2B 2B
7.8

9.8
38

38
27.3

27.3

4A 4A

One-touch fitting
8.4 1/8 [4(A), 2(B) port]
(Pitch) Applicable tube O.D.: ø4, ø5/32"
[4(A), 2(B) port]
45.8 P = 16
(Pitch) : ø6, ø1/4"
51.6 P = 16 : ø8, ø5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

77
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Valve
Dimensions: Series SY5000 Metal Base EX510

U
SS5Y5-50(R)S5:- Stations D -02:(D)
B

Sub-plate
D side U side
L3
M5 x 0.8 (External pilot)
5.3 L4
[Pilot EXH port]

Plug-in
(DIN rail mounting hole pitch: 12.5) Manual override
DIN rail holding screw
(For DIN rail mounting)
50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail bracket mounting screw 4(A) port side : Blue (For rubber seal)
20.5 19.6 (Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor)
2(B) port side : Yellow

DIN rail

Metal Base
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20
81.6

74.1
20
1P
24.6
20

Plug-in
43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

12.3 4 x ø4.5 SI Unit


(For mounting)
18 5 L2

Manifold Exploded View


28 (L5) L1

Type 50, 51, 52


34 M5 x 0.8 (External pilot)
[External pilot port]
1/4
[1(P), 5(EA), 3(EB) port] (Station 1) ------------- (Station n)

manual override)
(Slide locking

Connector Connecting Base


50RS5:- Stations UD

74.3
71.6

68.6
2B 2B
9.8

38
27.3

4A 4A
3
[Plug for external pilot]
2B
(For DIN rail
10

8.4
mounting)
(Pitch) 1/4
14.3

4A
45.8 P = 17.5 [4(A), 2(B) port]

Plug-in

: The above drawing shows when P,
E port entry is D.
: These figures show the “SS5Y5-50S5-05B-02”.

Manifold Exploded View


Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

78
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY7000 Metal Base EX510

U 02
SS5Y7-50(R)S5:- Stations D - KC
C:, N: :(D)
:, KN: D side U side
B
L3
5.3 L4 Manual override
(DIN rail mounting hole pitch: 12.5)
(Pitch) (Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 52 P = 19 4(A) port side : Blue (For rubber seal)
M5 x 0.8 (External pilot) (For DIN rail mounting) 20.5 19.6 (Light/surge voltage : Gray (For metal seal)
PE: Pilot EXH port suppressor) 2(B) port side : Yellow
DIN rail bracket mounting screw
(For DIN rail mounting)

(DIN rail)
BA BA BA BA B A

5.5
PE

14 A 14 A 14 A 14 A 14 A
5EA

116.7
23.8
28

35
102.1

133.2
92.1

84.6
24
1P
23.8
28.2

49.7
44.1

3EB

8
X

32.1

12 B 12 B 12 B 12 B 12 B

NC
NC
4 x ø4.5
SI Unit
(5.4)

18.1 (For mounting)


20.9 5 L2
34.5 M5 x 0.8 (External pilot) (L5) L1
40.5 X: External pilot port
3/8 (Station 1) (Station n)
[1(P), 5(EA), 3(EB) port]

(Slide locking manual override)


50RS5:- Stations UD

78.3
78.1

84
2B 2B

44.5
3

9.4
32.4
4A 4A
[Plug for external pilot]

2B

(For DIN rail


10.8

10
(Pitch)

mounting)
4A

14.3
46.6 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø8, ø5/16"

: The above drawing shows when P, : ø10, ø3/8"
E port entry is D.

: These figures show the “SS5Y7-50S5-05B-C10”.

Port size 02 One-touch fitting (Replaceable)

2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A

10.8 (Pitch) (Pitch)


46.6 P = 19 55.7 P = 19
(11)
One-touch fitting
(22.9) [4(A), 2(B) port]
1/4 (For ø12) Applicable tube O.D.: ø6, ø1/4"
[4(A), 2(B) port] : ø8, ø5/16"
: ø10, ø3/8"
: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
79
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Valve
Dimensions: Series SY3000 Metal Base EX510

M5, 01
SS5Y3-51S5:- Stations D- CKC::, N, :
KN:
: D side (Pitch) U side
45.1 P = 10.5 Manual override
18.5 19.6
(Push-turn locking slotted type:
)

Sub-plate
(Light/surge voltage
suppressor) Press, then rotate it.
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

Plug-in
B A B A B A B A B A

92.7
89
14 A 14 A 14 A 14 A 14 A
64.4

56.9
21.8 16
12 B 12 B 12 B 12 B 12 B

4 x ø4.5 SI Unit
(For mounting)
L1

Metal Base
(Max. 3)
(Station 1)---(Station n)

manual override)
(Slide locking

Plug-in
68.3
65.6
Panel fitting dimensions

62.6
16 17.8 (For 9 stations or more)

32
2 x ø4.5
4

(For 9 stations or more)

(4.1)

Manifold Exploded View


40 (Pitch)
One-touch fitting

Type 50, 51, 52


(For 9 stations or more) 4 x M4 x 0.7, thread depth 4 46.4 P = 10.5
[4(A), 2(B) port]
(For mounting) 23.6 Applicable tube O.D.: ø2
4 x ø4.5
: ø3.2, ø1/8"

21.1
29.8

3EB 2B 2B
52.4

: ø4, ø5/32"
56.4

16.8 16.8

: ø6, ø1/4"

56.4
1P
4 x M4 x 0.7
4 x ø4.5 5EA 4A 4A
4 4
Fitting dimensions for panel mounting
L3
C2, C3, C4 : 16
: 15

Connector Connecting Base


1/8
Refer to panel fitting dimensions for details.
L2 [1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3
C6

(For 9 stations or more) L2


: These figures show the
“SS5Y3-51S5-05D-C6”.

Port size M5 Port size 01 One-touch fitting (Replaceable)

Plug-in
Manifold Exploded View
32

32

32

Type 10, 11, 12


)

(Pitch) (Pitch) (Pitch)


C6: 12.8
N7: 16.6

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


17 20.1

17 20.1
14 21.1
29.8

29.8

29.8
(

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
Plug Assembly Part No.
One-touch Fittings/

5EA 4A 5EA 4A 5EA 4A

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
Manifold Options

: ø6, ø1/4"

Port Size M5, C:, N:, KC:, KN: Port Size 01


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5 L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 68.5 73.8 79 84.3 L3 — — — — — — — 77.8 84 90.3 96.5

80
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY5000 Metal Base EX510

01, 02
SS5Y5-51S5- Stations D - CKC::, N, :
KN:
: D side
50
(Pitch)
P = 16
U side

20.5 19.6 (Light/surge Manual override


voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
B A B A B A B A B A 2(B) port side : Yellow
14 A 14 A 14 A 14 A 14 A

106.2
116.6
81.6

74.1
20
30.2
12 B 12 B 12 B 12 B 12 B

4 x ø4.5
SI Unit
(For mounting)
(Max. 3) L1
(Station 1) ----------- (Station n)

manual override)
(Slide locking
74.3
71.6

68.6
38
Panel fitting dimensions
2 x ø4.5

(4.9)
(For 9 stations or more) 4 x M4 x 0.7, thread depth 5
5

(Pitch) 2 x M4 x 0.7
4 x ø4.5 (For mounting) 50 P = 16
20 25.2

(For 9 stations or more)


24
One-touch fitting
61.6
71.6

[4(A), 2(B) port]


3EB 2B 2B
40.2

4 x M4 x 0.7 Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
20

4 x ø4.5
1P 71.6 : ø8, ø5/16"
5 5
20

L3 5EA 4A 4A
L2 Fitting dimensions for panel mounting
Refer to panel fitting dimensions for details.
C4, C6 : 14.8
: 17.2

1/4
[1(P), 5(EA), 3(EB) port]
L3
L2
: These figures show the
C8

“SS5Y5-51S5-05D-C8”.

Port size 01 Port size 02 One-touch fitting (Replaceable)


38

38

38

(Pitch) (Pitch) (Pitch)


(15.5)

50 P = 16 50 P = 17.5 50 P = 16

3EB 2B 3EB 2B
40.2

40.2

40.2

3EB 2B
9.7

17.5

14.5
14.8

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C:, N:, KC:, KN: Port Size 02


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244 L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 74 90 106 122 138 154 170 186 202 218 234 L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 93 101 109 117 L3 — — — — — — — 100.5 109.3 118 126.8

81
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Valve
Dimensions: Series SY7000 Metal Base EX510

02
SS5Y7-51S5:- Stations D- CKC::, N, :
KN:
:(D) D side U side
Manual override

(
Push-turn locking slotted type:
)

Sub-plate
(Light/surge voltage suppressor)
Press, then rotate it.
(Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Gray (For metal seal)
20.5 19.6 2(B) port side : Yellow

Plug-in
4 x ø4.5
B A B A B A B A B A
(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
24
32.1

Metal Base
12 B 12 B 12 B 12 B 12 B

NC
NC
SI Unit

Plug-in
Port size 02 One-touch fitting (Replaceable)

Manifold Exploded View


(For ø12)

(Station 1) (Station n)
(29.5)

Type 50, 51, 52


(Slide locking manual override)
78.3
78.1

84
(17.6)

44.5

Connector Connecting Base


One-touch fitting
(5.4)
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
1/4 : ø8, ø5/16"
[4(A), 2(B) port] : ø10, ø3/8"
: ø12
32.8
33.1

3EB 2B 3EB 2B

4 x M4 x 0.7 thread depth 5

Plug-in
22.6

(For mounting)
22

1P 1P
3/8
[1(P), 5(EA), 3(EB) port]

Manifold Exploded View


5EA 4A 5EA 4A (Pitch) M4 x 0.7 thread depth 5
(Max. 3) 52 P = 19 Type 10, 11, 12
(For 9 stations or more)
27
Fitting dimensions for panel mounting
5

Refer to panel fitting dimensions


for details.
33.1

2B 2B
46.1

3EB
Panel fitting dimensions
23
81.1

22

4 x ø4.5 2 x ø4.5 1P
23

(For 9 stations or more)


5

Plug Assembly Part No.


One-touch Fittings/

5EA 4A 4A
27.1

One-touch fitting
[4(A), 2(B) port]
81.1
72.1

24

Applicable tube O.D. C8 : ø8


L3 C10: ø10
5 L2 N9 : ø5/16"
4 x M4 x 0.7 N11: ø3/8"
L1
Manifold Options

4 x ø4.5
5 5
L3
L2

: These figures show the “SS5Y7-51S5-05D-C10”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
82
Plug-in Metal Base EX510
Type 52
Top Ported
Series SY3000/5000/7000
How to Order Manifold

SS5Y 3 52 S5 05 D
/ 4 ) 0 1 6 2 *
/ Series 0 Wiring type 1 Valve stations
3 SY3000 Nil All double wiring
1 Symbol Stations Note
5 SY5000 S All single wiring
2 02 2 stations
All double
7 SY7000
1: All double wiring: 2-position single, double, wiring
3-position and 4-position valves can be used on 08 8 stations
all manifold stations. 02 2 stations
All single

2: All single wiring: Available only for the manifold
wiring
4 Type which has 2-position single for all stations. 12 12 stations
52 Top ported Note that 2-position double, 3- or 4-position

: This also includes the number of blanking
valves cannot be used.
52R Top ported, External pilot plate assembly.

: If a mix of single and double wiring is required, it is
supplied as a special order.

) SI Unit output polarity 6 P, E port entry


Nil Positive common U U side
1
N Negative common D D side
1
B Both sides

1: Plugs are mounted on the opposite side of
the selected ports.

How to Order Manifold Assembly 2 Thread type


Nil Rc
00F G
Example (SS5Y3-52S5-:)
00N NPT
2-position double (24 VDC)
2-position single (24 VDC) 00T NPTF
SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (3 sets)
3-position closed
center (24 VDC)
SY3330-5U1-C6 (1 set) * Mounting
Nil Direct mounting
DIN rail mounting
D (With DIN rail)
DIN rail mounting
D0 (Without DIN rail)
ide
Us
D3 For 3 stations
Specify a longer rail than
the standard length.
s
n
tio

D12 For 12 stations


ta
S

3
: Refer to page 271 for the fixation of DIN rail
2
1 mounting type manifold.
Manifold base ide
(5 stations) Ds
SS5Y3-52S5-05D

SS5Y3-52S5-05D ······ 1 set (Type 52 5-station manifold base part no.)



SY3130-5U1-C6 ······· 3 sets (2-position single part no.)

SY3230-5U1-C6 ······· 1 set (2-position double part no.)

SY3330-5U1-C6 ······· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc. For details on the EX510 Gateway-type Serial Transmission
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE System, refer to the WEB catalog or the Best Pneumatics No. 1
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDIN and the Operation Manual.
order from the 1st station as shown in the figure above. If the Please download the Operation Manual via SMC website,
arrangement becomes complicated, specify on a manifold specification http://www.smcworld.com
sheet.

83
Plug-in Metal Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 2 Coil type  A, B port size
3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000
: Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type when the valve is continuously 01 1/8 SY5000
energized for long periods of time. 02 1/4 SY7000
4 Type of actuation
: Be careful of the energizing time when the
One-touch fitting (Metric)

Metal Base
1 Single power saving circuit is selected. Refer to page
2-position 268 for details. Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed center C2 ø2 ) — —
4 3-position C3 ø3.2 ) — —
5
Exhaust center
Pressure center
* Rated voltage C4 ø4 ) ) —

Plug-in
5 24 VDC C6 ø6 ) ) )
A
1 4-position N.C./N.C.
B
1 dual N.O./N.O. C8 ø8 — ) )
3-port C10 ø10 — — )
C
1 N.C./N.O. - Light/surge voltage suppressor C12 ø12 — — )

1: Only rubber seal type is available for and common specification


the 4-position dual 3-port valve. One-touch fitting (Inch)

Manifold Exploded View


Symbol Surge voltage Common
With light Symbol A, B port SY3000 SY5000 SY7000
suppressor specification

Type 50, 51, 52


N1 ø1/8" ) — —
) Seal type R —
Non-polar N3 ø5/32" ) ) —
0 Rubber seal
U )
S — Positive N7 ø1/4" ) ) )
1 Metal seal ) N9 ø5/16" — ) )
Z ) common
NS — Negative N11 ø3/8" — — )
0 Pilot type NZ ) common
Nil Internal pilot
: Only “Z” and “NZ” types are available for with  Thread type

Connector Connecting Base


R External pilot the power saving circuit. Select a valve from
R, U, S or Z when the SI Unit polarity is Nil Nil Rc
(positive common). Select a valve from R, U, F G
NS or NZ when the SI Unit output polarity is N NPT
1 Back pressure check valve N (negative common). T NPTF
(Built-in valve type)
Nil None
: Only Nil is available for M5.
H Built-in  Manual override

: Only rubber seal type Nil: D:  Type of mounting screw

: Back pressure check valve is not Non-locking Push-turn Nil Round head combination screw

Plug-in
available for the 3-position type and the push type locking
SY7000.
B Hexagon socket head cap screw
slotted
K Round head combination screw (Falling-out-prevention type)
type
6 Pilot valve option H Hexagon socket head cap screw (Falling-out-prevention type)

Manifold Exploded View


Nil Standard (0.7 MPa)
: For “K” and “H”, the valve body cover has a Type 10, 11, 12
B Quick response type (0.7 MPa) drop prevention construction to stop the
K
1 High pressure type (1.0 MPa) mounting screws from falling out when the
E: F: valve is removed for maintenance etc.

1: Only metal seal type is available for Push-turn Slide locking


: When ordering a valve individually, the
the high pressure type. locking lever type base gasket is not included.
type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
service.
Plug Assembly Part No.

Refer to page 89 for part numbers of the


One-touch Fittings/


: Refer to page 31 for with the safety slide base gasket and mounting screw.
locking manual override.
: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options

Protective class
class  (Mark: )
84
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY3000 Metal Base EX510

U
SS5Y3-52(R)S5:- Stations D -:(D)
B

D side U side

DIN rail holding screw L3


(For DIN rail mounting) 5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
DIN rail bracket mounting screw

68.3
(For DIN rail mounting)
45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
(Slide locking manual override) 18.5 19.6 (Light/surge voltage 4(A) port side : Blue (For rubber seal)
suppressor) : Gray (For metal seal)
M5 x 0.8 (External pilot) 2(B) port side : Yellow
[Pilot EXH port]
DIN rail

B A B A B A B A B A

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
2B 2B 2B 2B 2B
3EB

8.6 4 x ø4.5 SI Unit 8


14.5 (For mounting) One-touch fitting
4 L2
[4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
28 : ø3.2, ø1/8"
M5 x 0.8
: ø4, ø5/32"
1/8 [4(A), 2(B) port] : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port]
(Station 1)---(Station n)
M5 x 0.8 (External pilot)
[External pilot port]
)
C6: 76.8
N7: 80.6
65.6
62.6

(
32

52RS5:- Stations UD
(For DIN rail
mounting)
7.5
11.8

3
[Plug for external pilot]


: These figures show the “SS5Y3-52S5-05B”.


: The above drawing shows when P,
E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

85
Plug-in Metal Base Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Valve
Dimensions: Series SY5000 Metal Base EX510

U
SS5Y5-52(R)S5:- Stations D -:(D)
B

Sub-plate
D side U side
L3
DIN rail holding screw 5.3 L4

Plug-in
(For DIN rail mounting) (DIN rail mounting hole pitch: 12.5) Manual override
DIN rail bracket mounting screw (Pitch)
(For DIN rail mounting) 50 P = 16 (Push-turn locking slotted type:
Press, then rotate it. )
74.3 20.5 19.6 4(A) port side : Blue (For rubber seal)
(Slide locking manual override) (Light/surge voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) 68.6 suppressor) 2(B) port side : Yellow
[Pilot EXH port]

01 : 16.2
C:: 14.5
DIN rail

Metal Base
5.5
B A B A B A B A B A
4A 4A 4A 4A 4A
PE
5EA

106.2
23.2

116.6
35
96.2

20
81.6

74.1
20
1P

Plug-in
24.6
20

43.8
40.2

40.2
3EB

30.2
X

2B 2B 2B 2B 2B 8

12.3 1/8

Manifold Exploded View


18 4 x ø4.5 SI Unit [4(A), 2(B) port]

Type 50, 51, 52


(For mounting) One-touch fitting
28 5 L2
[4(A), 2(B) port]
34 (L5) L1 Applicable tube O.D.: ø4, ø5/32"
1/4 : ø6, ø1/4"
: ø8, ø5/16"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port] (Station 1)----------- (Station n)

Connector Connecting Base


(86.7)
72.3

52RS5:- Stations UD
71.6

38

Plug-in
3
(For DIN rail
10

[Plug for external pilot]


mounting)
14.3

Manifold Exploded View


Type 10, 11, 12


: These figures show the “SS5Y5-52S5-05B”.

: The above drawing shows when P,
E port entry is D.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

86
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY7000 Metal Base EX510

U
SS5Y7-52(R)S5:- Stations D -:(D)
B

D side U side

L3
5.3 L4 Manual override
M5 x 0.8 (External pilot)
PE: Pilot EXH port
(DIN rail mounting hole pitch: 12.5)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (Pitch) 4(A) port side : Blue (For rubber seal)
84 52 P = 19 : Gray (For metal seal)
(For DIN rail mounting)
(Slide locking manual override) 78.3 (Light/surge voltage 2(B) port side : Yellow
20.5 19.6
DIN rail bracket mounting screw suppressor)
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A

5.5
PE

4 A 4 A 4 A 4 A 4 A
5EA

116.7
23.8
28
102.1

35

133.2
92.1

84.6
24
1P
23.8
28.2

49.7
45.6
44.1

22.6
3EB

8
X

32.1

2B 2B 2B 2B 2B

NC
NC
18.1 4 x ø4.5 1/4
20.9 (For mounting) [4(A), 2(B) port]
34.5 5 L2 One-touch fitting
40.5 (L5) L1 [4(A), 2(B) port]
Applicable tube O.D. : ø6, ø1/4"
3/8 : ø8, ø5/16"
[1(P), 5(EA), 3(EB) port] : ø10, ø3/8"
: ø12
M5 x 0.8 (External pilot)
X: External pilot port

(Station 1) (Station n)
52RS5:- Stations UD (A, B port: ø12)

3
(110.3)

[Plug for external pilot]


(98.4)
87
78.1

44.5

(For DIN rail


10

mounting)


: The above drawing shows when P,
14.3

E port entry is D.


: These figures show the “SS5Y7-52S5-05B”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

87
88
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View

Tightening torque: 1.4 N·m

Tightening torque: 1.4 N·m @

Holding screw

. It is mounted only for the DIN rail


mounting type (with DIN rail).

; It is mounted only for the DIN rail mounting type.


(Tightening torque of holding screw: 1.4 N·m)
Caution
: Refer to page 271 for the fixation of DIN rail
mounting type manifold.
Tightening torque
M2: 0.16 N·m (SY3000)
M3: 0.8 N·m (SY5000/7000)

Manifold Parts No.

Part no.
No. Description Note
SY3000 SY5000 SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A
Part numbers shown on the left are
Valve mounting combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
: screw
for 10 valves (20 pcs.).
Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (30 pcs. for the SY7000)
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
Base gasket Part numbers shown on the left are
@ (for plug-in metal base and sub-plate)
SY30M-11-1A SY50M-11-1A SY70M-11-1A for 10 valves (10 pcs.).
. DIN rail VZ1000-11-1-: VZ1000-11-4-: VZ1000-11-4-: Refer to page 249.
Clamp bracket assembly Part numbers shown on the left are for the clamp bracket
; SY30M-15-2A SY50M-15-2A SY70M-15-2A
(for plug-in metal base) assembly for one manifold (two sets of clamp brackets).

89
Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
Blanking plate assembly (With mounting screw)
Used when expecting valve additions, or for maintenance.
A structure to prevent screws falling out is in place on the blanking plate, making it much harder for the mounting screws to fall out.

Sub-plate
Plug-in
Metal Base
SY30M-26-2A (-B) SY50M-26-2A (-B) SY70M-26-2A (-B)

Refer to pages 260, 262, 264 for dimensions.


Refer to pages 250 to 254 for individual SUP/EXH and other options.

Plug-in
How to Order Blanking Plate Assembly

Manifold Exploded View


SY 0M 26 2 A

Type 50, 51, 52


Series
3 SY3000 Option for mounting
5 SY5000 With mounting screw
7 SY7000 Nil (Round head combination screw)
With mounting screw
B (Hexagon socket head cap screw)

Connector Connecting Base


(A) (B)
4 2 Base type
2 For plug-in metal base

5 1 3
(EA) (P) (EB)
Circuit diagram

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

90
91
Plug-in

Bottom ported
Side ported

Top ported
Connector Connecting Base

92
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 10, 11, 12
Plug-in Connector Connecting Base
Manifold Specifications

D-sub Terminal Circular


Flat ribbon cable Lead wire Serial wiring
connector block box connector
SA3 type
Model PG type SA2 type
S6:type (EX500) (EX500) S3:type
F type FW type P type J type PH type T type L type M type S: type
(EX600) S4:type (EX120)
G type (EX250)
(EX126)
(EX260)
Manifold type Plug-in connector connecting base
SUP/EXH port type Common SUP/EXH (Common for 3/5 port)
2 to 18
stations 2 to 8 2 to 20 2 to 16 2 to 24 2 to 16
Valve stations 2 to 24 stations (J/G type: 2 to 24 stations
2 to 16 stations stations stations stations stations
stations)
D-sub Flat ribbon cable connector
connector with strain relief
Dedicated
Conforming to Conforming to MIL-C-83503
connector
Applicable connector MIL-C-24308 (Refer to page 113.) —
(Refer to
JIS-X-5101 Socket: Socket: Socket:
page 111.)
(Refer to 26 pins 20 pins 10 pins
page 111.) MIL type MIL type MIL type
Internal wiring Positive common, Negative common
ø8 One-touch fitting
SY3000
ø5/16" One-touch fitting
1(P), 3/5(E) ø10 One-touch fitting
port SY5000
ø3/8" One-touch fitting
ø12 One-touch fitting
SY7000
Port ø1/2" One-touch fitting
size ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
SY3000
ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
4(A), 2(B) ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
port SY5000
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting
ø6 One-touch fitting, ø8 One-touch fitting, ø10 One-touch fitting, ø12 One-touch fitting
SY7000
ø1/4" One-touch fitting, ø5/16" One-touch fitting, ø3/8" One-touch fitting
IP67
1

) (( )
IP67
1 IP67
1 EX260 D-sub
communication
Enclosure (Based on IEC60529) IP40 IP67
1 IP40 IP67
1
( I/O Unit:
partially
IP40 )( EX500 GW
Unit, Input
Unit: IP65
connector: IP40
EX500 GW
Unit: IP65 )
IP20

1: In the case of a metal seal, there are restrictions in the operating environment. Refer to the Specific Product Precautions (page 266).

93
Type 10, 11, 12
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Manifold Flow Rate Characteristics
1/Manifold Weight
Valve Seal Type: Rubber Seal
Port size Valve flow rate characteristics
Weight: W [g]
2

Sub-plate
Model 1, 3/5 4, 2 1l4/2 (PlA/B) 4/2l5/3 (A/BlE)
(n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-10 (Side ported) C8 C6 1.4 0.30 1.6 0.19 28.9n + 293
SS5Y3-12 (Top ported) 25.1n + 314

Plug-in
C8 C6 1.2 0.29 1.3 0.19
SS5Y5-10 (Side ported) C10 C8 3.3 0.30 3.6 0.17 74.7n + 398
SS5Y5-11 (Bottom ported) C10 C8 3.3 0.29 4.2 0.26 76.8n + 445
SS5Y5-12 (Top ported) C10 C8 2.8 0.27 3.8 0.23 66.3n + 417
SS5Y7-10 (Side ported) C12 C12 6.2 0.23 5.9 0.20 106.6n + 496
SS5Y7-11 (Bottom ported) C12 C12 6.2 0.25 6.6 0.21 117.9n + 532
SS5Y7-12 (Top ported) C12 C12 5.6 0.31 5.7 0.24 84.1n + 519

Metal Base
Valve Seal Type: Metal Seal
Port size Valve flow rate characteristics
Weight: W [g]
2
Model 1, 3/5 4, 2 1l4/2 (PlA/B) 4/2l5/3 (A/BlE)

Plug-in
(n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-10 (Side ported) C8 C6 1.2 0.19 1.3 0.18 28.9n + 293
SS5Y3-12 (Top ported) C8 C6 1.2 0.16 1.3 0.18 25.1n + 314
SS5Y5-10 (Side ported) C10 C8 2.7 0.24 3.1 0.17 74.7n + 398

Manifold Exploded View


SS5Y5-11 (Bottom ported) 0.25 3.5 0.15 76.8n + 445

Type 50, 51, 52


C10 C8 2.8
SS5Y5-12 (Top ported) C10 C8 2.6 0.18 3.0 0.16 66.3n + 417
SS5Y7-10 (Side ported) C12 C12 4.4 0.14 4.4 0.17 106.6n + 496
SS5Y7-11 (Bottom ported) C12 C12 4.6 0.16 4.7 0.18 117.9n + 532
SS5Y7-12 (Top ported) C12 C12 3.9 0.21 4.1 0.14 84.1n + 519

1: The value is for manifold base with 5 stations and individually operated 2-position type.

2: Weight: W is the value of the internal pilot, and D-sub connector manifold with One-touch fitting straight piping type.

Connector Connecting Base


To obtain the weight with valves attached, add the valve weights given on page 15 for the appropriate number of stations.

: Calculation of effective area S and sonic conductance C: S = 5.0 x C

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

94
Series SY3000/5000/7000

Connector Wiring Layout


For both serial and parallel wiring, additional valves are sequentially assigned pins on the connector.
This makes it completely unnecessary to disassemble the connector unit.

Single solenoid valve is installed to all double wiring. (in the case of all double wiring)
(Manifold specification sheet is not necessary.)
Solenoid Connector side
(D-sub connector etc.)

Common (+, –)
SOL.a
Station 1
SOL.b
SOL.a Station 2
Unused terminal
SOL.a Station 3
SOL.b

···
Double solenoid Single solenoid Double solenoid
Station 3 (Double wiring) Station 1
Station 2

Single/double wiring are mixed.


(Manifold specification sheet is necessary.) Connector side
Solenoid
(D-sub connector etc.)

Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
SOL.a
SOL.b Station 3
···

Double solenoid Single solenoid Double solenoid


Station 3 Station 2 Station 1


: These diagrams are for the purpose of explanation, and differ from the connector wiring used for testing.

95
96
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
Type 10
Side Ported D-sub Connector Flat Ribbon Cable PC Wiring

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and SS5Y 3 10 F 1 05 U C6


209 (SY7000) for dimensions
of Type 11/Bottom ported type. / 4 ) 0 1 6 2 * -
/ Series 4 Type ) Connector type
3 SY3000 10 Side ported F: D-sub connector <IP40> FW: D-sub connector <IP67> P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 11 Bottom ported
1 (25 pins) New (25 pins) (26 pins) (20 pins)
7 SY7000
1: The SY5000 manifold base is used for
the bottom ported of the SY3000. When
ordering, refer to “Plug-in Mixed Mounting
Type Manifold” (from page 213).

0 Connector entry direction


1: Upward 2: Lateral
: The connector entry di- PH: Flat ribbon cable J: PC wiring (20 pins) G: PC wiring (20 pins)
rection for connector (10 pins) Yellow ink New with power supply terminal
type "FW" D-sub con- Yellow ink
nector <IP67> can not
be rotated. If it is nec-
essary to change, or-
der connector block
assembly (page 231)
separately.

1 Valve stations
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
How to Order Manifold Assembly 02 2 stations 02 2 stations
Double wiring
1 Double wiring
1
12 12 stations 12 12 stations
Example (SS5Y3-10F1-:) 02 2 stations Specified layout
2 02 2 stations Specified layout
2
2-position double (24 VDC) (Available up to (Available up to
2-position single (24 VDC) SY3200-5U1 (1 set) 24 24 stations 24 solenoids) 24 24 stations 24 solenoids)
SY3100-5U1 (3 sets) 3-position closed
center (24 VDC) PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
SY3300-5U1 (1 set) Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring
1 Double wiring
1
09 9 stations 04 4 stations
LOC 02 2 stations Specified layout
2 02 2 stations Specified layout
2
ide
K
FRE Us (Available up to (Available up to
E s
on 18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
ati
St
Manifold base 3 J/G: PC wiring (20 pins)
1: Double wiring: 2-position single,
2 double, 3-position and 4-position
(5 stations) 1 Symbol Stations Note
e valves can be used on all
SS5Y3-10F1-05D-C6
D sid 02 2 stations
manifold stations.
Double wiring
1
Use of a 2-position single
SS5Y3-10F1-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) 08 8 stations solenoid will result in an unused

SY3100-5U1 ················· 3 sets (2-position single part no.) 02 2 stations Specified layout
2 control signal. If this is not

SY3200-5U1 ················· 1 set (2-position double part no.) (Available up to desired, order with a specified

SY3300-5U1 ················· 1 set (3-position closed center part no.) 16 16 stations 16 solenoids) layout.
The asterisk denotes the symbol for assembly.
2: Specified layout: Indicate the wiring specifications on the manifold
Prefix it to the part numbers of the valve etc. specification sheet. (Note that 2-position double, 3-position and 4-
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE position valves cannot be used where single wiring has been specified.)
s Under the manifold part number, state the valves to be mounted in order
: This also includes the number of blanking plate assembly.
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 110.


In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
97
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
6 P, E port entry 2 SUP/EXH block assembly - Mounting and Option
U U side (2 to 10 stations) Nil Internal pilot Option DIN Rail Option
Symbol Mounting
D D side (2 to 10 stations) Internal pilot, Name plate Station number Nil Direct mounting
S
B Both sides (2 to 24 stations) Built-in silencer Nil — — 0 Without DIN rail (with bracket)
Direct
R External pilot AA mounting ) ) 3 For 3 stations Specify a longer rail

Metal Base

: 3/5(E) port is plugged for the BA ) — than the total length
built-in silencer type. D; — — 24 For 24 stations of specified stations.
DIN rail
A; mounting ) )
B; ) —

: Enter the number of stations inside : when it is larger than the number

Plug-in
of valve stations. (Refer to “DIN Rail Option” above.)

: Only direct mounting is available for Type 11 (Bottom ported).

: Refer to page 271 for the fixation of DIN rail mounting type manifold.

Manifold Exploded View


* A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Type 50, 51, 52


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —
Straight

C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )

Connector Connecting Base


C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —
Upward

CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Plug-in
L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1

Manifold Exploded View


(Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)
Type 10, 11, 12
B10 ø10 — — ) — — P, E port size
ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)
Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
Plug Assembly Part No.
One-touch Fittings/

The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).
Manifold Options

Protective class
class  (Mark: )
98
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type

4 Type of actuation
1 Single E: F:
2-position
2 Double 2 Coil type Push-turn Slide locking
3 Closed center Nil Standard locking lever type
4 3-position Exhaust center T With power saving circuit (Continuous duty type) type
5 Pressure center
: Be sure to select the power saving circuit
A
1 4-position N.C./N.C. type when the valve is continuously
B
1 dual N.O./N.O. energized for long periods of time.
C
1 3-port N.C./N.O.
: Be careful of the energizing time when the
: Refer to page 31 for with the safety slide
power saving circuit is selected. Refer to page locking manual override.

1: Only rubber seal type is available for the 268 for details.
4-position dual 3-port valve.

* Rated voltage  Type of mounting screw


) Seal type 5 24 VDC
Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
6 12 VDC
1 Metal seal K Round head combination screw (Falling-out-prevention type)

: Connector type "G" (PC wiring with power
supply terminal) of the manifold type is only
H Hexagon socket head cap screw (Falling-out-prevention type)
available in 24 VDC.
: For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
0 Pilot type mounting screws from falling out when the
Nil Internal pilot valve is removed for maintenance etc.
R External pilot - Light/surge voltage suppressor
: When ordering a valve individually, the
and common specification base gasket is not included.
Since the base gasket is attached to the
Surge voltage Common
Symbol With light manifold, please order the base gasket
suppressor specification
1 Back pressure check valve (Built-in valve type) Nil — —
separately if it is needed for maintenance
service.
Nil None R — Non-polar Refer to page 244 for part numbers of the
H Built-in U ) base gasket and mounting screw.

: Only rubber seal type. Manifold installed type S — Positive


: “B” and “H” cannot be selected for the
is available if the back pressure check valve ) common individual SUP/EXH spacer assembly,
Z )
is required for a valve with metal seal. Refer interface regulator or double check spacer
to page 256 for Ordering Example. However,
NS — Negative assembly with residual pressure release
NZ ) common valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
: Only “Z” and “NZ” types are available for with
the same time because it will reduce the the power saving circuit.
flow.
: For connector type "G" (PC wiring with power

: The built-in valve type back pressure check supply terminal) of the manifold type, select
valve is not available for the 3-position type non-polar or positive common.
and the SY7000.

Protective class
class  (Mark: )
99
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base D-sub Connector (IP40)

C2
U
SS5Y3-10F 21 - Stations D - C3, N1
C4, N3 (D)
B C6, N7

Sub-plate
D side U side
Manual override
1
DIN rail holding screw (L5)
(For DIN rail mounting) (8)
L1
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
( JIS-X-5101
)

Plug-in
Applicable connector: D-sub equivalent (Light/surge voltage suppressor) : Gray (For metal seal)
MIL-C-24308 2(B) port side : Yellow

(5.5)
(8)
LOCK

B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

70.6
83

60.5
FREE

Metal Base
(40.9)
44.8

4.6
12 B 12 B 12 B 12 B 12 B

2 x M2.6
4.6
9.5

1.7
)
(4.9)

C6: 3.6
N7: 7.4
2 x 4-40 UNC

Plug-in
(Connector entry
[4(A), 2(B) port: 4 x M4 Mounting hole
N (inch size)] upward direction)
19.6 ( L2 1.5
(Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)

Manifold Exploded View


(L3)

Type 50, 51, 52


One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
(Station 1)---(Station n) : ø3.2, ø1/8"
6.1 : ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P

Connector Connecting Base


(62.7)

63.1
13.6
10.6
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
(7.5)

One-touch fitting
(11.8)

(Pitch)
[1(P), 3/5(E) port] 31.4 15.5 P = 10.5 (17.8)
Applicable tube O.D.: ø8, ø5/16"

Plug-in
Manifold Exploded View
Type 10, 11, 12


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10F2-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5

100
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base D-sub Connector (IP40)

U C4, N3
SS5Y5-10F 12 - Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override
1
(L5) L1
DIN rail holding screw
(For DIN rail mounting) (8)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail
(Light/surge voltage suppressor)
: Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
LOCK

BA BA BA BA BA

(35)
70.6 14 A 14 A 14 A 14 A 14 A
97.5

113.4
FREE

81.2
(61.7)
65.6

5.5
12 B 12 B 12 B 12 B 12 B
10.9
30.3

4.7
2 x M2.6 (5.9)
(8.3)

4 x M5 Mounting hole
2 x 4-40 UNC
[4(A), 2(B) port: 21.9 L2 1.5 (Fitting for the type with P/E
N (inch size)] ports on the U and/or D sides)
(5.3) (L4)
(Connector entry upward direction) (DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
6.1
14.1

1 P 1 P

73.2
(62.7)

8.7

2 B2 B2 B2 B2 B
56.6
48.6

12.4
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A

One-touch fitting
(For DIN rail
(7.5)

mounting)

[1(P), 3/5(E) port] (Pitch)


(11.8)

Applicable tube O.D.: ø10, ø3/8" 35.9 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10F2-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22

101
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base D-sub Connector (IP40)

U C6, N7
SS5Y7-10F 12- Stations DB - C8,
C10, N11(D)
N9
C12
D side U side

Sub-plate
Manual override
1
DIN rail holding screw (L5) L1
(For DIN rail mounting)
(8) (Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(
JIS-X-5101
)

Plug-in
Applicable connector: D-sub equivalent (Light/surge voltage suppressor)
MIL-C-24308 : Gray (For metal seal)
2(B) port side : Yellow

(8)
(DIN rail)
LOCK

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

Metal Base
FREE

(5.5)

96.7
(77.1)
79.5

44.2

12 B 12 B 12 B 12 B 12 B

5.5

Plug-in
8.8

3.9
2 x M2.6
(6)
(9.3)

2 x 4-40 UNC
(17.9)

(A, B port: ø12) 4 x M5 Mounting hole


[4(A), 2(B) port: N (inch size)]

Manifold Exploded View


20.7 L2 1.5 (Fitting for the type with P/E

Type 50, 51, 52


(Connector entry upward direction) ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
(Station 1) (Station n)

Connector Connecting Base


: ø8, ø5/16"
: ø10, ø3/8"
: ø12
6.1
2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(62.7)

56.6
48.6

14.2

11.1

3/5 E 3/5 E
35.2

8.7

31.6

4 A4 A4 A4 A4 A

Plug-in
Manifold Exploded View
(For DIN rail

(Pitch)
(10)

One-touch fitting (21.7)


mounting)

Type 10, 11, 12


(14.3)

[1(P), 3/5(E) port] 39.5 20.5 P = 19


Applicable tube O.D.: ø12, ø1/2"


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10F2-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20

102
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base D-sub Connector (IP67)

U C2
SS5Y3-10FW 12 - Stations D - C3, N1
C4, N3 (D)
B C6, N7
D side U side
(L5) Manual override
1
L1
DIN rail holding screw
(15)
( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
(Connector entry upward direction)
2(B) port side : Yellow

DIN rail

(8)

(5.5)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

92.6
83
70.6

60.5
(40.9)
38.7

12 B 12 B 12 B 12 B 12 B

4.6
3.4

4.6
1.7
(4.9)

)
C6: 3.6
N7: 7.4

2 x M2.6
4 x M4 Mounting hole
(
2 x 4-40 UNC
[4(A), 2(B) port: N (inch size)]
36.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Applicable connector: D-sub
( JIS-X-5101
MIL-C-24308 )
equivalent (L3)

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2, ø1/8"
Applicable tube O.D.: ø8, ø5/16" : ø3, ø5/32"
: ø4, ø1/4"
4.5
: ø6

1 P 1 P
(61.1)

63.1
56.6

10.6
13.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
23
18

(For DIN rail

(17.8)
(7.5)

(Pitch)
mounting)
(11.8)

48.3 15.5 P = 10.5


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10FW2-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5 242 252.5 263 273.5 284 294.5 305 315.5 326 336.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 300 312.5 312.5 325 337.5 350 362.5
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5
103
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY5000 Connector Connecting Base D-sub Connector (IP67)

U C4, N3
SS5Y5-10FW 21 - Stations D- C6, N7 (D)
B C8, N9
D side U side

Sub-plate
Manual override
1

DIN rail holding screw


(L5) L1
(
Push-turn locking slotted type:
Press, then rotate it. )
(15) 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage suppressor)
(Connector entry upward direction)

Plug-in
: Gray (For metal seal)
2(B) port side : Yellow
DIN rail
(8)

(5.5)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

97.5
70.6

113.4

Metal Base
81.2
(61.7)
59.5

5.5
12 B 12 B 12 B 12 B 12 B
24.2

Plug-in
10.9
4.7
(5.9)
(8.3)

2 x M2.6
2 x 4-40 UNC 4 x M5 Mounting hole
[4(A), 2(B) port: 36 L2 1.5
(5.3) (Fitting for the type with P/E
N (inch size)] (L4)
ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)

Manifold Exploded View


(
Applicable connector: D-sub JIS-X-5101 equivalent)

Type 50, 51, 52


MIL-C-24308 (L3)

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø10, ø3/8" : ø6, ø1/4"
: ø8, ø5/16"

Connector Connecting Base


4.5
14.1

1 P 1 P
73.2
8.7
(61.1)

2 B2 B2 B2 B2 B
56.6

3/5 3/5
33.4

E E
29.1
23

4 A4 A4 A4 A4 A
12.4

(For DIN rail

(Pitch)
(7.5)

Plug-in
mounting)

(20.5)
(11.8)

50 18 P = 16

Manifold Exploded View


Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10FW2-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 122.5 138.5 154.5 170.5 186.5 202.5 218.5 234.5 250.5 266.5 282.5 298.5 314.5 330.5 346.5 362.5 378.5 394.5 410.5 426.5 442.5 458.5 474.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 237.5 262.5 275 287.5 300 325 337.5 350 375 387.5 400 412.5 437.5 450 462.5 487.5 500
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5

104
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base D-sub Connector (IP67)

U C6, N7
SS5Y7-10FW 12 - Stations D - C8, N9 (D)
B C10, N11
C12
D side U side

Manual override
1
(L5) L1
DIN rail holding screw
(For DIN rail mounting) (15) (Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
(Connector entry upward direction) : Gray (For metal seal)
2(B) port side : Yellow

(8)
(DIN rail)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

(5.5)

96.7
(77.1)
74.9

12 B 12 B 12 B 12 B 12 B

5.5
39.6
8.8

3.9
(6)
(9.3)

2 x M2.6
(17.9)

2 x 4-40 UNC (A, B port: ø12) 4 x M5 Mounting hole


[4(A), 2(B) port: N (inch size)]
36.2 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
Applicable connector: D-sub
( JIS-X-5101
MIL-C-24308 )
equivalent (DIN rail mounting hole pitch: 12.5)
(L3)

(Station 1) (Station n) One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port] : ø10, ø3/8"
Applicable tube O.D.: ø12, ø1/2" : ø12
4.5 2
82.7

1 P 1 P
2 B2 B2 B2 B2 B
(61.1)

56.6
11.1

3/5 E 3/5 E
8.7
35.2

31.6

4 A4 A4 A4 A4 A
23
14.2

(For DIN rail

(Pitch)
(10)

(21.7)
mounting)
(14.3)

55 20.5 P = 19


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10FW2-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 136.7 155.7 174.7 193.7 212.7 231.7 250.7 269.7 288.7 307.7 326.7 345.7 364.7 383.7 402.7 421.7 440.7 459.7 478.7 497.7 516.7 535.7 554.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 223 248 260.5 285.5 298 323 335.5 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 212.5 237.5 250 275 287.5 312.5 325 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5

105
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base Flat Ribbon Cable

P C2
U
SS5Y3-10 PG 1 C3, N1
PH 2 - Stations D - C4, N3 (D) D side U side
J B C6, N7
(L5) L1 Manual override
1

Sub-plate
(Connector entry upward direction)
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
Triangle mark DIN rail (8)
2(B) port side : Yellow

Plug-in
voltage suppressor)

(5.5)
(8)
LOCK

B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

70.6
83

60.5
FREE

(40.9)
44.8

4.6

Metal Base
12 B 12 B 12 B 12 B 12 B
4.6
9.5

N7: 7.4 )

1.7
(4.9)
3.6
(Fitting for the type
Applicable connector:
with P/E ports on the

(C6:
26 pins MIL type with strain relief

Plug-in
U and/or D sides)
(Conforming to MIL-C-83503) 19.6 L2 1.5 4 x M4 Mounting hole
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Manifold Exploded View


For PC wiring with power One-touch fitting

Type 50, 51, 52


supply terminals (Station 1)---(Station n) [4(A), 2(B) port]
Applicable tube O.D.: ø2
18.8
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P 1 P
: ø6, ø1/4"
(75.4)

63.1
10.6
13.6
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

Connector Connecting Base


(Pitch) (For DIN rail
(7.5)

One-touch fitting 7.9 31.4 15.5 P = 10.5 (17.8) mounting)


(11.8)

[1(P), 3/5(E) port]


Applicable tube O.D.: ø8, ø5/16"


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10P2-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.

Plug-in

: Only connectors are different for 10PG, 10PH, 10J and 10G. L1 to L5 dimensions are the same as 10P type.

10PJG (20 pins) 10PH (10 pins) 10G (20 pins)

Manifold Exploded View


For PC wiring Switch for locking a connector Type 10, 11, 12
Triangle mark Triangle mark LED Triangle mark
Power supply terminal
(+COM
24 VDC
)
− (Negative)
LOCK
LOCK

LOCK

+ (Positive)
PCW type

(M3 terminal screw)


FREE

Plug Assembly Part No.


FREE

FREE

44.8

One-touch Fittings/

Applicable connector: Applicable connector: Applicable connector: 20 pins


20 pins MIL type with strain relief 10 pins MIL type with strain relief MIL type with strain relief
Manifold Options

(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5
106
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Flat Ribbon Cable

P
U C4, N3
SS5Y5-10 PG 1
PH 2 - Stations D - C6, N7 (D)
D side U side
J B C8, N9 Manual override
1
(L5) L1

(Connector entry upward direction)


DIN rail holding screw
(For DIN rail mounting)
(8) (Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
Triangle mark DIN rail : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
LOCK

BA BA BA BA BA

(35)
70.6
14 A 14 A 14 A 14 A 14 A

97.5

113.4
FREE

81.2
(61.7)
65.6

5.5
12 B 12 B 12 B 12 B 12 B
30.3
10.9

4 x M5 Mounting hole

4.7
(5.9)
(8.3)
Applicable connector: (Fitting for the type with P/E
26 pins MIL type with strain relief 21.9 L2 1.5
ports on the U and/or D sides)
(Conforming to MIL-C-83503) (5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3) One-touch fitting
For PC wiring with power
supply terminals [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
18.8
(75.4)

14.1
1 P 1 P

73.2
8.7
56.6

2 B2 B2 B2 B2 B
48.6

12.4
33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A

(For DIN rail


One-touch fitting
(7.5)
(Pitch)

mounting)
(11.8)
[1(P), 3/5(E) port] 7.9 35.9 18 P = 16 (20.5)
Applicable tube O.D.: ø10, ø3/8"

10PJG (20 pins) 10PH (10 pins) 10G (20 pins)


For PC wiring Triangle mark Switch for locking a connector

1: Refer to page 206 for LED


dimensions of external pilot, Triangle mark Triangle mark
Power supply terminal
silencer, elbow fittings and
slide locking manual override. ( 24 VDC
+COM )

: These figures show the −(Negative)


LOCK
LOCK

+(Positive)
LOCK

“SS5Y5-10P2-05D-C8”.
PCW type

(M3 terminal screw)

: Refer to page 211 for


dimensions of A or B port
FREE
FREE

top-ported type.
FREE

: Only connectors are different


65.6

for 10PG, 10PH and 10J.


L1 to L5 dimensions are the
same as 10P type.

Applicable connector: Applicable connector: Applicable connector: 20 pins


20 pins MIL type with strain relief 10 pins MIL type with strain relief MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22
107
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base Flat Ribbon Cable
P
PG U C6, N7
SS5Y7-10 PH D 12 - Stations DB - C8, N9
C10, N11 (D)
J C12 D side U side Manual override
1
G
(
Push-turn locking slotted type:
)

Sub-plate
(L5) L1
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) (8) (Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
Triangle mark (Connector entry upward direction) 2(B) port side : Yellow

Plug-in
(8)
(DIN rail)
LOCK

B A B A B A B A B A

(35)
70.6 14 A 14 A 14 A 14 A 14 A

128.8
115
FREE

(5.5)

96.7
(77.1)
79.5

Metal Base
44.2

12 B 12 B 12 B 12 B 12 B

5.5

Plug-in
8.8

3.9
(6)
(9.3)

Applicable connector:
(A, B port: ø12)
(17.9)

26 pins MIL type with strain relief


20.7 L2 1.5 4 x M5 Mounting hole
(Conforming to MIL-C-83503)
(5.3) (L4) (Fitting for the type with P/E
(DIN rail mounting hole pitch: 12.5) ports on the U and/or D sides)

Manifold Exploded View


(L3)

Type 50, 51, 52


One-touch fitting
One-touch fitting (Station 1) (Station n) [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø6, ø1/4"
Applicable tube O.D.: ø12, ø1/2" : ø8, ø5/16"
: ø10, ø3/8"
18.8

2
: ø12

1: Refer to page 207 for dimensions

82.7
1 P 1 P
(75.4)

of external pilot, silencer, elbow 2 B2 B2 B2 B2 B

Connector Connecting Base


56.6
fittings and slide locking manual
48.6

14.2

3/5 E 3/5 E
11.1
8.7
35.2

override.
31.6
4 A4 A4 A4 A4 A

: These figures show the “SS5Y7-


10P2-05D-C8”.

: Refer to page 212 for dimensions


of A or B port top-ported type. (For DIN rail
(Pitch)
(10)

: Only connectors are different for (21.7) mounting)


(14.3)

10PG, 10PH, 10J and 10G. L1 to 39.5 20.5 P = 19


L5 dimensions are the same as
10P type.

Plug-in
10PJG (20 pins) 10PH (10 pins) 10G (20 pins)
For PC wiring LED Switch for locking a connector

Manifold Exploded View


Triangle mark
Triangle mark Power supply terminal Triangle mark Type 10, 11, 12
24 VDC
(
+COM )
–(Negative)
LOCK

LOCK

LOCK

+(Positive)
PCW type

PCW type

(M3 terminal screw)


FREE

FREE

FREE

Plug Assembly Part No.


65.6

One-touch Fittings/

Applicable connector: Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief 20 pins MIL type with strain relief
Manifold Options

(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20
108
Plug-in Connector Connecting Base
D-sub Connector Flat Ribbon Cable PC Wiring
Type 12
Top Ported
Series SY3000/5000/7000 RoHS
How to Order Manifold

SS5Y 3 12 F 1 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top ported type. / 4 ) 0 1 6 2 *
/ Series ) Connector entry direction
3 SY3000 1: Upward 2: Lateral
: The connector entry di-
5 SY5000 rection for connector type
7 SY7000 "FW" D-sub connector
<IP67> can not be ro-
4 Connector type LOC
K
LOC
K
tated. If it is necessary to
F: D-sub connector <IP40> FW: D-sub connector <IP67> P: Flat ribbon cable change, order connector
PG: Flat ribbon cable FRE
E
FRE
E

(25 pins) New (25 pins) (26 pins) block assembly (page
(20 pins)
231) separately.

0 Valve stations
LOC
K
LOC
K
LOC
K
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
FRE
E
FRE
E
FRE
E
Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring
1 Double wiring
1
PH: Flat ribbon cable J: PC wiring (20 pins) G: PC wiring (20 pins) 12 12 stations 12 12 stations
(10 pins) Yellow ink New with power supply terminal 02 2 stations Specified layout
2 02 2 stations Specified layout
2
Yellow ink (Available up to (Available up to
24 24 stations 24 solenoids) 24 24 stations 24 solenoids)

LOC LOC
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
K K
FRE PC FRE
Symbol Stations Note Symbol Stations Note
E W ty E
pe
02 2 stations 02 2 stations
Double wiring
1 Double wiring
1
09 9 stations 04 4 stations
1 P, E port entry
1: 6 For type “S”, supply/exhaust 02 2 stations Specified layout
2 02 2 stations Specified layout
2
U
1 U side (2 to 10 stations) block assembly with built-in (Available up to (Available up to
D
1 D side (2 to 10 stations) silencer, choose U or D for P port 18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
B Both sides (2 to 24 stations) entry.
J/G: PC wiring (20 pins)
1: Double wiring: 2-position
Symbol Stations Note single, double, 3-position and
How to Order Manifold Assembly 02 2 stations 4-position valves can be used
Double wiring
1 on all manifold stations.
Use of a 2-position single
08 8 stations
Example (SS5Y3-12F1-:) 02 2 stations Specified layout
2
solenoid will result in an
2-position double (24 VDC) unused control signal. If this is
2-position single (24 VDC) (Available up to not desired, order with a
SY3230-5U1-C6 (1 set) 16 solenoids)
SY3130-5U1-C6 (3 sets) 16 16 stations specified layout.
3-position closed
2: Specified layout: Indicate the wiring specifications on the manifold
center (24 VDC) specification sheet. (Note that 2-position double, 3-position and
SY3330-5U1-C6 (1 set) 4-position valves cannot be used where single wiring has been
specified.)

: This also includes the number of blanking plate assembly.

6 SUP/EXH block assembly * Mounting


LOC
K Nil Internal pilot Nil Direct mounting
ide
FRE
E Us Internal pilot, D DIN rail mounting (With DIN rail)
S
Built-in silencer
s

D0 DIN rail mounting (Without DIN rail)


n
tio
ta

R
S

External pilot D3 For 3 stations Specify a longer


3

Manifold base
: For built-in silencer type, P and rail than the
2

(5 stations)
1

id e E ports are available on U and D24 For 24 stations standard length.


SS5Y3-12F1-05D Ds D sides. 3/5(E) port is plugged.

: Refer to page 271 for the
The silencer exhaust port is
SS5Y3-12F1-05D ······ 1 set (Type 12 5-station manifold base part no.) located on the opposite side of fixation of DIN rail mounting

SY3130-5U1-C6 ········ 3 sets (2-position single part no.) P, E port entry. (Example: When type manifold.

SY3230-5U1-C6 ········ 1 set (2-position double part no.) the P, E port entry is D side, the

SY3330-5U1-C6 ········ 1 set (3-position closed center part no.) silencer exhaust port is U side.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
2 P, E port size (One-touch fittings)
Symbol SY3000 SY5000 SY7000
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDINORDER Nil ø8 ø10 ø12
from the 1st station as shown in the figure above.
If the arrangement becomes complicated, specify on a manifold N ø5/16" ø3/8" ø1/2"
specification sheet.

: For N, sizes are in inches.
109
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
4 Type of actuation high pressure type. 02 1/4 SY7000
1

Metal Base
Single One-touch fitting (Metric)
2
2-position
Double 2 Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed center Nil Standard
C2 ø2 ) — —
4 3-position Exhaust center T With power saving circuit (Continuous duty type)
C3 ø3.2 ) — —
5 Pressure center
: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
A
1 N.C./N.C. type when the valve is continuously
4-position C6 ø6 ) ) )
energized for long periods of time.
B
1 dual N.O./N.O. C8 ø8 — ) )

: Be careful of the energizing time when the
C
1 3-port N.C./N.O. C10 ø10 — — )
power saving circuit is selected. Refer to page

1: Only rubber seal type is available for the 268 for details. C12 ø12 — — )
4-position dual 3-port valve.
One-touch fitting (Inch)
* Rated voltage

Manifold Exploded View


Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


5 24 VDC N1 ø1/8" ) — —
) Seal type 6 12 VDC N3 ø5/32" ) ) —
0 Rubber seal
: Connector type "G" (PC wiring with power supply terminal) N7 ø1/4" ) ) )
1 Metal seal of the manifold type is only available in 24 VDC. N9 ø5/16" — ) )
N11 ø3/8" — — )
- Light/surge voltage suppressor
and common specification
0 Pilot type  Thread type
Surge voltage Common

Connector Connecting Base


Nil Internal pilot Symbol With light Nil Rc
suppressor specification
R External pilot F G
Nil — —
R — Non-polar N NPT
U ) T NPTF
1 Back pressure check valve S — Positive
Only Nil is available for M5.
(Built-in valve type) ) common
Z )
Nil None NS — Negative
H Built-in NZ ) common  Type of mounting screw

: Only rubber seal type. Manifold installed type

Plug-in

: Only “Z” and “NZ” types are available for with Nil Round head combination screw
is available if the back pressure check valve the power saving circuit. B Hexagon socket head cap screw
is required for a valve with metal seal. Refer
: For connector type "G" (PC wiring with power K Round head combination screw (Falling-out-prevention type)
to page 256 for Ordering Example. However, supply terminal) of the manifold type, select
H

Manifold Exploded View


it is not recommended to use the built-in Hexagon socket head cap screw (Falling-out-prevention type)
non-polar or positive common.
valve type and the manifold installed type at
: For “K” and “H”, the valve body cover has a Type 10, 11, 12
the same time because it will reduce the drop prevention construction to stop the
flow. mounting screws from falling out when the

: The built-in valve type back pressure check  Manual override valve is removed for maintenance etc.
valve is not available for the 3-position type Nil: D:
: When ordering a valve individually, the
and the SY7000. Non-locking Push-turn base gasket is not included.
push type locking Since the base gasket is attached to the
slotted manifold, please order the base gasket
type separately if it is needed for maintenance
service.
Plug Assembly Part No.
One-touch Fittings/

Refer to page 244 for part numbers of the


base gasket and mounting screw.

: “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type
Manifold Options


: Refer to page 31 for with safety slide locking
manual override.

Protective class
class  (Mark: )
110
Series SY3000/5000/7000

Electrical Wiring Specifications Cable Assembly


015 015
D-sub connector
AXT100-DS25- 030 (N) [IP40] SY30M-DS25- 030 (N) [IP67]
050 050
Nil: Metric Nil: Metric
If alignment is not
N: Inch N: Inch
specified, the internal
1
14 2 wiring is double wiring
15 (connected to SOL. a and Cable Cable
3 0.3 mm2 x 25 cores 0.3 mm2 x 25 cores
16 4 SOL. b) regardless of
17 O.D. ø1.4 O.D. ø1.4
5 number of stations, valve
18 6
19 and option types. Approx. ø10
7
20 8
21 Approx. ø8
9 Connector terminal no. Seal (Length)
22 10
23 015
11
24 12
L Molded cover
25 13 2 x M2.6 x 0.45
or Seal (Length)
44

2 x 4 − 40 UNC 015
Connector JBZ-25S-3 Connector hood
Terminal no. Polarity
8

made by J.S.T. Mfg.

L
SOL.a Co.,Ltd.
1 (−) (+)
(2.4)

Station 1 SOL.b 55
14 (−) (+)
SOL.a Socket side 2 x M2.6 x 0.45
2 (−) (+) 14 25

(86.5)
Station 2 SOL.b or
15 (−) (+)
SOL.a Terminal no. 2 x 4 − 40 UNC
16

3 (−) (+)
Station 3 SOL.b
16 (−) (+)
SOL.a 1 13
(−) (+)

8.7
4 47.04
Station 4 SOL.b
17 (−) (+)
SOL.a
5 (−) (+)
Station 5 SOL.b
18 (−) (+) Connector
SOL.a
6 (−) (+) JBZ-25S-3 made by
Station 6 SOL.b
19 (−) (+) J.S.T. Mfg. Co.,Ltd.
SOL.a
7 (−) (+)
Station 7 SOL.b 14…………25 Socket side
20 (−) (+)
SOL.a
8 (−) (+)
22

Station 8 SOL.b
21 (−) (+) Terminal no.
SOL.a
9 (−) (+)
Station 9 SOL.b 1…………13
22 (−) (+) 47.04
SOL.a
10 (−) (+)
Station 10 SOL.b
23 (−) (+)
SOL.a D-sub connector cable assembly [IP40] D-sub connector cable assembly [IP67]
11 (−) (+)
Station 11 SOL.b
24 (−) (+) Cable Cable
SOL.a Assembly part no. Note Assembly part no. Note
12 (−) (+) length (L) length (L)
Station 12 SOL.b
25 (−) (+) 1.5 m AXT100-DS25-015 1.5 m SY30M-DS25-015
Cable Cable
3m AXT100-DS25-030 0.3 mm2 x 25 cores 3m SY30M-DS25-030
0.3 mm2 x 25 cores
COM. 5m AXT100-DS25-050 5m SY30M-DS25-050
13 (+) (−)
Positive Negative
When using a standard commercial
Be sure to use the connector cable
common common connector, use a 25-pin type female assembly in the table, to satisfy enclosure
connector conforming to MIL-C-24308. IP67.

: When using a valve with no polarity, either positive
Cannot be used for movable wiring.
Cannot be used for movable wiring.
common or negative common can be used.
Lengths other than the above are also
available. Please contact SMC for details.

Specified Layout Electrical characteristics Connector Manufacturers’ Example


Item Property s&UJITSU,IMITED
(25 pins) Mixed wiring of single and
Conductor resistance s*APAN!VIATION%LECTRONICS)NDUSTRY ,IMITED
double wiring can be specified >/km, 20nC 65 or less
s*34-FG#O ,TD
on the manifold specification s()2/3%%,%#42)##/ ,4$
Voltage limit
1 sheet. The maximum number V, 1 minute, AC 1000
14 2
15 3
of stations is determined
16 Insulation resistance
17
4 according to the number of M>/km, 20nC 5 or more
5
18 6 solenoids. The total number of
19 7
The minimum bending radius
20 8
solenoids should be 24 or less. of the D-sub connector cable
21
22
9 1 solenoid is required for is 20 mm.
10
23
24
11 2-position single, and 2
25
12
13 solenoids for 2-position double, D-sub connector cable assembly terminal numbers
3-position and 4-position. Terminal
no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
COM.
White
White

White
Brown

Brown
Orange
Yellow

Yellow
Orange
Yellow

Orange
Purple

Purple
Black

Black
Gray

Gray

Gray
Blue

Blue
Pink

Pink

Pink

Lead wire
2ED

2ED

color
White

White

White
White

White
Black
Black

Black
Black

Black
None
None
None
None
None
None
None

None
None

None

Dot
2ED
2ED
2ED

2ED
2ED

marking

111
Plug-in Connector Connecting Base Series SY3000/5000/7000

Electrical Wiring Specifications

Valve
Flat ribbon cable connector
If alignment is not specified, the internal
wiring is double wiring (connected to SOL.
26 25
24 23
a and SOL. b) regardless of number of
22 21 stations, valve and option types.
20 19

Sub-plate
18 17
16 15
14 13
12 11 Connector terminal no.
10 9

Plug-in
8 7
Triangle mark indicator position
6 5
4 3
2 1

P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins) G: Flat ribbon cable (20 pins)
<Double wiring> <Double wiring> PC wiring (with power supply terminal)
Terminal no. Polarity Terminal no. Polarity Terminal no.
SOL.a SOL.a

Metal Base
1 (−) (+) 1 (−) (+) SOL.a 20
Station 1 SOL.b Station 1 SOL.b 20 19
2 (−) (+) 2 (−) (+) Station 1 SOL.b
SOL.a SOL.a 18
3 (−) (+) 3 (−) (+)
Station 2 SOL.b Station 2 SOL.b SOL.a 16
4 (−) (+) 4 (−) (+)
SOL.a SOL.a 18 17 Station 2 SOL.b
5 (−) (+) 5 (−) (+) 14
Station 3 SOL.b Station 3 SOL.b
6 (−) (+) 6 (−) (+) SOL.a

Plug-in
SOL.a SOL.a 12
7 (−) (+) 7 (−) (+) 16 15 Station 3
Station 4 SOL.b Station 4 SOL.b SOL.b 10
8 (−) (+) 8 (−) (+)
SOL.a 9 (−) (+) SOL.a 9 (−) (+) SOL.a 8
Station 5 SOL.b Station 5 SOL.b Station 4
10 (−) (+) 10 (−) (+) 14 13 SOL.b 6
SOL.a 11 (−) (+) SOL.a 11 (−) (+)
Station 6 SOL.b Station 6 SOL.b SOL.a 19
12 (−) (+) 12 (−) (+)

Manifold Exploded View


SOL.a SOL.a Station 5 SOL.b
13 (−) (+) 13 (−) (+) 12 11 17

Type 50, 51, 52


Station 7 SOL.b Station 7 SOL.b SOL.a
14 (−) (+) 14 (−) (+) 15
SOL.a 15 (−) (+) SOL.a 15 (−) (+) Station 6 SOL.b 13
Station 8 SOL.b Station 8 SOL.b 10 9
16 (−) (+) 16 (−) (+)
SOL.a SOL.a SOL.a 11
17 (−) (+) 17 (−) (+)
Station 9 SOL.b Station 9 SOL.b Station 7 SOL.b
18 (−) (+) 18 (−) (+) 8 7 9
SOL.a 19 (−) (+) COM. SOL.a
Station 10 SOL.b 19 (+) (−) 7
20 (−) (+) COM. Station 8 SOL.b
SOL.a 20 (+) (−) 5
21 (−) (+) Positive Negative 6 5
Station 11 SOL.b 22 (−) (+) common common

Connector Connecting Base


SOL.a 23 (−) (+)
Station 12 SOL.b 4 3
24 (−) (+)
COM.
25 (+) (−)
COM. J: Flat ribbon cable (20 pins)
26 (+) (−) 2 1
Positive Negative PC wiring
common common <Double wiring> Triangle mark 3,4
Terminal no. Polarity
SOL.a 20 (−) (+)
Station 1 SOL.b 18 (−) (+)
SOL.a 1,2

Plug-in
16 (−) (+) 24 VDC − +
Station 2 SOL.b 14 (−)
PH: Flat ribbon cable (10 pins) (+)
SOL.a Power supply terminal
12 (−) (+)
<Double wiring> Station 3 SOL.b 10 (−) (+)

Manifold Exploded View


Terminal no. Polarity SOL.a
8 (−) (+)
SOL.a Station 4 SOL.b Type 10, 11, 12
1 (−) (+) 6 (−) (+)
Station 1 SOL.b SOL.a
: This circuits are for the specifications with up to
2 (−) (+) 19 (−) (+)
SOL.a Station 5 SOL.b 8 stations of 2-position double, 3-position and
3 (−) (+) 17 (−) (+)
Station 2 SOL.b SOL.a 4-position dual 3 port valve. There should be
4 (−) (+) 15 (−) (+)
SOL.a Station 6 SOL.b wired in order 20l18l16l14 without skipping
5 (−) (+) 13 (−) (+)
Station 3 SOL.b SOL.a or leaving any connectors remaining.
6 (−) (+) 11 (−) (+)
SOL.a Station 7 SOL.b
: For details on PC wiring system, refer to the
7 (−) (+) 9 (−) (+)
Station 4 SOL.b SOL.a WEB catalog or the Best Pneumatics No. 1.
8 (−) (+) 7 (−) (+)
Station 8 SOL.b
COM. 5 (−) (+)
9 (+) (−)
COM.
Plug Assembly Part No.

10 (+) (−) 4 (−) (+)


One-touch Fittings/

Positive Negative 3 (−) (+)


common common COM. 2 (+) (−)
COM. 1 (+) (−)
Positive Negative
common common

: When using a valve with no polarity,
either positive common or negative
Manifold Options


: This circuits are for the specifications
common can be used.
with up to 8 stations of 2-position
double, 3-position and 4-position dual
3 port valve. There should be wired in
order 20l18l16l14 without skipping
or leaving any connectors remaining.

: For details on PC wiring system, refer
to the WEB catalog or the Best
Pneumatics No. 1.

112
Series SY3000/5000/7000

Flat Ribbon Cable Assembly


10 1
AXT100-FC 20 - 2
26 3

6 Terminal no. 28AWG


2ed

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
26

25
(15.6)
L

Flat ribbon cable connector assembly


Cable Assembly part no. Connector Manufacturers’ Example
length (L) 26 pins 20 pins 10 pins
s()2/3%%,%#42)##/ ,4$
1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
s-*APAN,IMITED
3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2 s&UJITSU,IMITED
5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3 s*APAN!VIATION%LECTRONICS)NDUSTRY ,IMITED
s*34-FG#O ,TD

: When using a standard commercial connector, use a 26-pin, 20-pin or 10-pin
s/KI%LECTRIC#ABLE#O ,TD
TYPECONNECTORCONFORMINGTO-), # WITHSTRAINRELIEF

#ANNOTBEUSEDFORMOVABLEWIRING

,ENGTHSOTHERTHANTHEABOVEAREALSOAVAILABLE0LEASECONTACT3-#FORDETAILS

Specified Layout

C/M. C/M.

26 25
24 23 C/M. C/M.
22 21
20 19 20 19 20 19
18 17 18 17 18 17
16 15 16 15 16 15
14 13 14 13 C/M. C/M. 14 13
12 11 12 11 12 11
10 9 10 9 10 9
10 9
8 7 8 7 8 7
8 7
6 5 6 5 6 5
6 5
4 3 4 3 4 3
4 3
2 1 2 1 2 1
2 1
C/M. C/M.
(P: 26 pins) (PG: 20 pins) (PH: 10 pins) (J,G: 20 pins PC wiring)

Mixed wiring of single and double wiring can be specified on the manifold specification. The maximum number of stations is determined according to the number of
solenoids. The total number of solenoids should be 24 or less for P, 18 or less for PG, 8 or less for PH, and 16 or less for J/G. 1 solenoid is required for 2-position single, and
2 solenoids for 2-position double, 3-position and 4-position.

113
114
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
Type 10
Side Ported Terminal Block Box

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 3 10 T 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type.

/ Series ) Valve stations 0 P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
7 SY7000 Double wiring
1 B Both sides (2 to 20 stations)
10 10 stations
02 2 stations
Specified layout
2
4 Type (Available up to 20 solenoids)
10 Side ported 20 20 stations 1 SUP/EXH block assembly
11 Bottom ported
1
1: Double wiring: 2-position single, double, 3-position and Nil Internal pilot
4-position valves can be used on all manifold stations. S Internal pilot, Built-in silencer

1: The SY5000 manifold base is


Use of a 2-position single solenoid will result in an
used for the bottom ported of
unused control signal. If this is not desired, order with a
R External pilot
the SY3000. When ordering,
: 3/5(E) port is plugged for the built-in silencer
specified layout.
refer to “Plug-in Mixed type.

2: Specified layout: Indicate the wiring specifications with
Mounting Type Manifold”
: When the built-in silencer type is used, keep
the manifold specification sheet. (Note that 2-position
(from page 213). the exhaust port from coming in direct
double, 3-position and 4-position valves cannot be used
where single wiring has been specified.) contact with water or other liquids.

: This also includes the number of blanking plate
assembly.
Refer to the page on the right for .
How to Order Manifold Assembly

Example (SS5Y3-10T-:)
2 Mounting and Option
Option
2-position double (24 VDC) Symbol Mounting
Name plate Station number
2-position single (24 VDC) SY3200-5U1 (1 set) Nil — —
SY3100-5U1 (3 sets) 3-position closed Direct
AA mounting
) )
center (24 VDC)
BA ) —
SY3300-5U1 (1 set)
D: — —
DIN rail
A: mounting
) )
B: ) —

: Enter the number of stations inside : when it
is larger than the number of valve stations.
ide (Refer to “DIN Rail Option” below.)
Us
s
: Only direct mounting is available for Type 11
at ion
St (Bottom ported).
3
: Refer to page 271 for the fixation of DIN rail
2
1 mounting type manifold.
e
D sid
DIN Rail Option
Manifold base Nil Direct mounting
(5 stations)
SS5Y3-10T-05D-C6
0 Without DIN rail (with bracket)
3 For 3 stations
Specify a longer rail than the
SS5Y3-10T-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) total length of specified stations.

SY3100-5U1 ··············· 3 sets (2-position single part no.) 20 For 20 stations

SY3200-5U1 ··············· 1 set (2-position double part no.)

SY3300-5U1 ··············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
sUnder the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 122.


In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
115
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
6 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Metal Base
Straight
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —

Manifold Exploded View


Downward

Type 50, 51, 52


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —
L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class  (Mark: )
116
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the high slotted
pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port N.O./N.O.
C
1 N.C./N.O. power saving circuit is selected. Refer to page
268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC
) Seal type 6 12 VDC
 Type of mounting screw
Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
- Light/surge voltage suppressor H Hexagon socket head cap screw (Falling-out-prevention type)
and common specification
: For “K” and “H”, the valve body cover has a
0 Pilot type Symbol With light
Surge voltage Common drop prevention construction to stop the
mounting screws from falling out when the
Nil Internal pilot suppressor specification
valve is removed for maintenance etc.
R External pilot Nil — —
: When ordering a valve individually, the
R — Non-polar base gasket is not included.
U ) Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
1 Back pressure check valve (Built-in valve type) Z )
) common separately if it is needed for maintenance
Nil None NS — Negative service.
Refer to page 244 for part numbers of the
H Built-in NZ ) common
base gasket and mounting screw.

: Only rubber seal type. Manifold installed type


: Only “Z” and “NZ” types are available for with
: “B” and “H” cannot be selected for the
is available if the back pressure check valve the power saving circuit. individual SUP/EXH spacer assembly,
is required for a valve with metal seal. Refer interface regulator or double check spacer
to page 256 for Ordering Example. However, assembly with residual pressure release
it is not recommended to use the built-in valve.
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
117
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base Terminal Block Box

C2
U
SS5Y3-10T- Stations D - C3, N1
C4, N3 (D)
B C6, N7

Sub-plate
D side U side

(L5) L1

Plug-in
Manual override
1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
(8)
DIN rail 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow
D side

U side

(5.5)

Metal Base
(8)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
126

83

92.6
80

60.5
(40.9)

Plug-in
12 B 12 B 12 B 12 B 12 B

4.6

20.4
4.6
1.7
16

)
(4.9)

1 4 x M4 Mounting hole
C6: 3.6
N7: 7.4

Manifold Exploded View


Type 50, 51, 52
2 x M5 Mounting hole (Fitting for the type with P/E
ports on the U and/or D sides)
(

7.1 88.2 L2 1.5

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


One-touch fitting One-touch fitting
[1(P), 3/5(E) port] [4(A), 2(B) port]
2 x G3/4 Applicable tube O.D.: ø8, ø5/16" Applicable tube O.D.: ø2
Conduit port : ø3.2, ø1/8"
(Station 1)---(Station n) : ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P
77.7

63.1
13.6
10.6

56.6
45.5

3/5 E 2 B 3/5 E

Plug-in
B2 B2 B2 B2
40.2

21.6

4 A4 A4 A4 A4 A
18

13.2

Manifold Exploded View


(For DIN rail
(7.5)

Type 10, 11, 12


mounting)

34.9
(11.8)

(Pitch)
107.1 15.5 P = 10.5 (17.8)


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.
One-touch Fittings/


: These figures show the “SS5Y3-10T-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3 321.8 332.3 342.8 353.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16

118
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Terminal Block Box

U C4, N3
SS5Y5-10T- Stations D - C6, N7 (D)
B C8, N9

D side U side

DIN rail holding screw


(L5) L1 Manual override
1
(For DIN rail mounting) DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail 4(A) port side : Blue (For rubber seal)
(8) : Gray (For metal seal)
(Light/surge
2(B) port side : Yellow
voltage suppressor)
D side

U side

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
126.4

97.5

113.4
80

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
16.4

10.9
1

4.7
(5.9)
(8.3)

2 x M5 Mounting hole
4 x M5 Mounting hole
7.1 87.7 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
2 x G3/4
: ø6, ø1/4"
Conduit port : ø8, ø5/16"
77.7

1 P 1 P
14.1

73.2
8.7

2 B2 B2 B2 B2 B
56.6
45.5

33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
13.2

12.4

(For DIN rail


(7.5)

mounting)

34.9
(11.8)

(Pitch)
108.8 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10T-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 460.5 485.5 498
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425 437.5 450 475 487.5
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5

119
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base Terminal Block Box

C6, N7
U
SS5Y7-10T- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side

(L5) L1 Manual override


1

DIN rail holding screw (


Push-turn locking slotted type:
)

Plug-in
DIN rail holding screw Press, then rotate it.
(8)
(For DIN rail mounting) (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
D side
2(B) port side : Yellow

U side
(8)
(DIN rail)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
141.8
80

128.8
115
(5.5)

96.7
(77.1)

Plug-in
12 B 12 B 12 B 12 B 12 B

5.5
31.8

8.8
3.9
(6)
(9.3)

2 x M5 Mounting hole

Manifold Exploded View


(17.9)

(A, B port: ø12) 4 x M5 Mounting hole

Type 50, 51, 52


7.1 87.9 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting One-touch fitting

Connector Connecting Base


[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø12, ø1/2" Applicable tube O.D.: ø6, ø1/4"
(Station 1) (Station n) : ø8, ø5/16"
2 x G3/4 : ø10, ø3/8"
: ø12
Conduit port 2
82.7

1 P 1 P
77.7

2 B2 B2 B2 B2 B

Plug-in
56.6
45.5

11.1

3/5 E 3/5 E
8.7
35.2

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


14.2
13.2

Type 10, 11, 12


(For DIN rail
(10)

34.9 (21.7)
mounting)

(Pitch)
(14.3)

113.8 20.5 P = 19


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.
One-touch Fittings/


: These figures show the “SS5Y7-10T-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5 480.5 499.5 518.5 537.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 562.5
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12 15 12 15 18

120
Plug-in Connector Connecting Base
Terminal Block Box
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12T 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top ported type. / 4 ) 0 1 6
/ Series 4 Valve stations 0 SUP/EXH block assembly
3 SY3000 Symbol Stations Note Nil Internal pilot
5 SY5000 02 2 stations S Internal pilot, Built-in silencer
7 SY7000 Double wiring
1 R External pilot
10 10 stations
: For built-in silencer type, P and E ports are
02 2 stations available on U and D sides. 3/5(E) port is
Specified layout
2
) P, E port entry (Available up to 20 solenoids)
plugged. The silencer exhaust port is located
on the opposite side of P, E port entry.
U
1 U side (2 to 10 stations) 20 20 stations
(Example: When the P, E port entry is D side,
D
1 D side (2 to 10 stations)
1: Double wiring: 2-position single, double, the silencer exhaust port is U side.)
3-position and 4-position valves can be
: When the built-in silencer type is used, keep
B Both sides (2 to 20 stations)
used on all manifold stations. the exhaust port from coming in direct contact

1: 0For type “S”, supply/exhaust block Use of a 2-position single solenoid will
assembly with built-in silencer, choose U or with water or other liquids.
result in an unused control signal. If this is
D for P port entry. not desired, order with a specified layout.

2: Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be 1 P, E port size
used where single wiring has been (One-touch fittings)
specified.)

: This also includes the number of blanking
Symbol SY3000 SY5000 SY7000
plate assembly. Nil ø8 ø10 ø12
N ø5/16" ø3/8" ø1/2"

: For N, sizes are in inches.
How to Order Manifold Assembly

Example (SS5Y3-12T-:)
2-position double (24 VDC) 6 Mounting
SY3230-5U1-C6 (1 set) Nil Direct mounting
2-position single (24 VDC) 3-position closed DIN rail mounting
SY3130-5U1-C6 (3 sets) center (24 VDC) D
(With DIN rail)
SY3330-5U1-C6 (1 set) DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations
Specify a longer rail than
the standard length.
D20 For 20 stations

: Refer to page 271 for the fixation of DIN rail
ide
Us mounting type manifold.
s
n
tio
ta
S
3
2
1

ide
Ds
Manifold base
(5 stations)
SS5Y3-12T-05D
SS5Y3-12T-05D ············ 1 set (Type 12 5-station manifold base part no.)

SY3130-5U1-C6 ············ 3 sets (2-position single part no.)

SY3230-5U1-C6 ············ 1 set (2-position double part no.)

SY3330-5U1-C6 ············ 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDIN
order from the 1st station as shown in the figure above. If the
arrangement becomes complicated, specify on a manifold specification
sheet.

121
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the high 01 1/8 SY5000
pressure type. 02 1/4 SY7000
4 Type of actuation

Metal Base
1 Single One-touch fitting (Metric)
2-position
2 Double 2 Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed center Nil Standard C2 ø2 ) — —
4 3-position Exhaust center T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
5 Pressure center
: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
A
1 N.C./N.C. type when the valve is continuously C6 ø6 ) ) )
4-position energized for long periods of time. C8 ø8 — ) )
B
1 dual 3-port
N.O./N.O.
C
1 N.C./N.O.
: Be careful of the energizing time when the C10 ø10 — — )
power saving circuit is selected. Refer to page C12 ø12 — — )

1: Only rubber seal type is available for the 268 for details.
4-position dual 3-port valve. One-touch fitting (Inch)

Manifold Exploded View


A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


Symbol
* Rated voltage N1 ø1/8" ) — —
) Seal type 5
6
24 VDC
12 VDC
N3 ø5/32" ) ) —
0 Rubber seal N7 ø1/4" ) ) )
1 Metal seal N9 ø5/16" — ) )
N11 ø3/8" — — )

- Light/surge voltage suppressor


and common specification
0 Pilot type

Connector Connecting Base


Nil Internal pilot Symbol With light
Surge voltage Common  Thread type
suppressor specification Nil Rc
R External pilot
Nil — — F G
R — Non-polar N NPT
U ) T NPTF
1 Back pressure check valve S —
)
Positive
: Only Nil is available for M5.
(Built-in valve type) Z ) common
Nil None NS — Negative

Plug-in
H Built-in NZ ) common

: Only rubber seal type. Manifold installed type


: Only “Z” and “NZ” types are available for with  Type of mounting screw
is available if the back pressure check valve the power saving circuit. Nil Round head combination screw
B Hexagon socket head cap screw

Manifold Exploded View


is required for a valve with metal seal. Refer
to page 256 for Ordering Example. However, K Round head combination screw (Falling-out-prevention type)
Type 10, 11, 12
it is not recommended to use the built-in  Manual override H Hexagon socket head cap screw (Falling-out-prevention type)
valve type and the manifold installed type at Nil: D:
: For “K” and “H”, the valve body cover has a
the same time because it will reduce the flow. Non-locking Push-turn drop prevention construction to stop the

: The built-in valve type back pressure check push type locking mounting screws from falling out when the
valve is not available for the 3-position type slotted type valve is removed for maintenance etc.
and the SY7000.
: When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
Plug Assembly Part No.
One-touch Fittings/

separately if it is needed for maintenance


E: F: service.
Push-turn Slide locking Refer to page 244 for part numbers of the
locking lever type base gasket and mounting screw.
type
: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
122
Series SY3000/5000/7000

Terminal Block Connection


Step 1. Removing the terminal block cover Step 2. The below diagram shows the terminal block wiring.
Loosen the 4 mounting screws (M4) to remove the All stations are provided with double wiring
terminal block cover. regardless of the mounted valves.
Connect each wire to the power supply side, according
Terminal block cover to the markings provided inside the terminal block.
Mounting screw (M4)
M3 screw

'ASKET

m
6m
Electrical entry
X'

Step 3. Mounting the terminal block cover


Securely tighten the screws to the torque shown in the
below table only after confirming that the gasket is
installed correctly.
Proper tightening torque [N·m] s!PPLICABLECRIMPEDTERMINAL 3 9  9 . 9 
0.7 to 1.2
s.AMEPLATE661 . 4
s$RIP PROOFPLUGASSEMBLYFOR' !84 "!

Electrical Wiring Specifications (IP67 compatible)


Standard wiring Specified Layout
Terminal no. Polarity Mixed wiring of single and double wiring can
SOL.a
1A (−) (+) be specified on the manifold specification
Station 1 SOL.b
1B (−) (+) sheet. The maximum number of stations is
1A

1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

SOL.a
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

2A

2A (−) (+) determined according to the number of


2B

Station 2 SOL.b
3A

2B (−) (+) solenoids. The total number of solenoids


3B

SOL.a
4A

3A (−) (+) should be 20 or less. 1 solenoid is required for


4B

Station 3 SOL.b
5A

3B (−) (+) 2-position single, and 2 solenoids for


5B

SOL.a
6A 7A

(−)
6B

4A (+) 2-position double, 3-position and 4-position.


Station 4 SOL.b
7B

4B (−) (+)
8A

SOL.a
8B

5A (−) (+)
9A 10A COM

Station 5 SOL.b
9B 10B

5B (−) (+)
SOL.a
6A (−) (+)
Station 6 SOL.b
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

6B (−) (+)
SOL.a
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7A (−) (+)
Station 7 SOL.b
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7B (−) (+)
SOL.a
8A (−) (+)
If alignment is not specified, the Station 8 SOL.b
8B (−) (+)
internal wiring is double wiring SOL.a
9A (−) (+)
(connected to SOL. a and SOL. b) Station 9 SOL.b
regardless of number of stations, 9B (−) (+)
SOL.a
valve and option types. 10A (−) (+)
Station 10 SOL.b
10B (−) (+)


7HENUSINGAVALVEWITHNO COM. (+) (−)
polarity, either positive Positive Negative
common or negative common common common
can be used.

123
124
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
Type 10
Side Ported Lead Wire

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 3 10 L1 1 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type.

/ Series ) Number of cores 1 Valve stations


3 SY3000 (Lead wire) (L1:) (L3:)
5 SY5000 L1 34 cores Symbol Stations Note Symbol Stations Note
7 SY7000 L2 17 cores 02 2 stations 02 2 stations
L3 9 cores Double wiring
1 Double wiring
1
16 16 stations 04 4 stations
02 2 stations Specified layout
2 02 2 stations Specified layout
2
4 Type (Available up to (Available up to
10 Side ported 0 Lead wire length 24 24 stations 32 solenoids) 08 8 stations 8 solenoids)
11 Bottom ported
1 1 0.6 m

4HE39MANIFOLDBASEIS 2 1.5 m (L2:)


used for the bottom ported of 3 3m Symbol Stations Note
the SY3000. When ordering, 02 2 stations
refer to “Plug-in Mixed Double wiring
1
-OUNTING4YPE-ANIFOLDv
08 8 stations
(from page 213).
02 2 stations Specified layout
2
(Available up to
16 16 stations 16 solenoids)

1: Double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.

2: Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-10L11-:) specification sheet. (Note that 2-position double, 3-position and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
2-position single (24 VDC)
SY3200-5U1 (1 set) specified.)
3-position closed
4HISALSOINCLUDESTHENUMBEROFBLANKINGPLATEASSEMBLY
SY3100-5U1 (3 sets)
center (24 VDC)
SY3300-5U1 (1 set)
6 P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)

e
U sid 2 SUP/EXH block assembly
ions
Stat Nil Internal pilot
3 S Internal pilot, Built-in silencer
2
1 R External pilot
e
D sid

: 3/5(E) port is plugged for the built-in silencer type.
Manifold base
7HENTHEBUILT INSILENCERTYPEISUSED KEEPTHEEXHAUSTPORTFROM
(5 stations) coming in direct contact with water or other liquids.
SS5Y3-10L11-05D-C6
SS5Y3-10L11-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)

SY3100-5U1 ··················· 3 sets (2-position single part no.)

SY3200-5U1 ··················· 1 set (2-position double part no.)

SY3300-5U1 ··················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 132.


In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
125
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
* A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
- Mounting and Option
Option DIN Rail Option
Symbol Mounting

Manifold Exploded View


Name plate Station number Nil Direct mounting
Nil — — 0 Without DIN rail (with bracket) Type 10, 11, 12
Direct
AA mounting
) ) 3 For 3 stations Specify a longer rail than the
···

···

BA ) — total length of specified


D: — — 24 For 24 stations stations.
DIN rail
A: mounting
) )
B: ) —

: Enter the number of stations inside : when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)

: Only direct mounting is available for Type 11 (Bottom ported).


Plug Assembly Part No.
One-touch Fittings/

: Refer to page 271 for the fixation of DIN rail mounting type manifold.
Manifold Options

126
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the high slotted
pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A
1 N.C./N.C. long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C
1 N.C./N.O.
268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal is available for the locking manual override.


4-position dual 3-port valve.
* Rated voltage
5 24 VDC
 Type of mounting screw
) Seal type 6 12 VDC
Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Falling-out-prevention type)
- Light/surge voltage suppressor H Hexagon socket head cap screw (Falling-out-prevention type)
and common specification
: For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
0 Pilot type Symbol With light
Surge voltage Common
suppressor specification mounting screws from falling out when the
Nil Internal pilot valve is removed for maintenance etc.
Nil — —
R External pilot
: When ordering a valve individually, the
R — Non-polar
base gasket is not included.
U ) Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
)
1 Back pressure check valve Z ) common separately if it is needed for maintenance
(Built-in valve type) NS — Negative service.
common Refer to page 244 for part numbers of the
Nil None NZ )
base gasket and mounting screw.
H Built-in
: Only “Z” and “NZ” types are available for with
: “B” and “H” cannot be selected for the

: Only rubber seal type. Manifold installed type the power saving circuit. individual SUP/EXH spacer assembly,
is available if the back pressure check valve interface regulator or double check spacer
is required for a valve with metal seal. Refer assembly with residual pressure release
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
127
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base Lead Wire

C2
1 U
SS5Y3-10L 2 :- Stations D - C3, N1
C4, N3 (D)
3 B C6, N7
D side U side
Manual override
1

Sub-plate
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge : Gray (For metal seal)

Plug-in
2(B) port side : Yellow
voltage suppressor)

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
67.8

60.5
(40.9)

Metal Base
4.6
12 B 12 B 12 B 12 B 12 B
17

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

Plug-in
4 x M4 Mounting hole
18 ( (Fitting for the type with P/E
ports on the U and/or D sides)
43 L2 1.5
(Lead wire length)

(L4)
0.6 m, 1.5 m, 3 m

18 (5.3)

Manifold Exploded View


(DIN rail mounting hole pitch: 12.5)

Type 50, 51, 52


(L3)

One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø2
[1(P), 3/5(E) port] (Station 1)---(Station n) : ø3.2, ø1/8"
Applicable tube O.D.: ø8, ø5/16" : ø4, ø5/32"

Connector Connecting Base


: ø6, ø1/4"
1 P 1 P
13.6
10.6

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


(7.5)

mounting)

(Pitch)
(11.8)

Plug-in
54.8 15.5 P = 10.5 (17.8)

Manifold Exploded View


Type 10, 11, 12


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10L1:-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

128
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Lead Wire

1 U C4, N3
SS5Y5-10L 2 :- Stations D - C6, N7 (D)
3 B C8, N9
D side U side
Manual override
1
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
64.4

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

4 x M5 Mounting hole
18
(Fitting for the type with P/E
18
42.5 L2 1.5
ports on the U and/or D sides)
(Lead wire length)
0.6 m, 1.5 m, 3 m

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"
14.1

1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
8.7
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
12.4

(For DIN rail


(7.5)

mounting)

(Pitch)
(11.8)

56.5 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10L1:-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

129
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base Lead Wire

C6, N7
1 U
SS5Y7-10L 2 :- Stations D - C8, N9
C10, N11 (D)
3 B C12

Sub-plate
D side U side

Manual override
1
(L5) L1
(
Push-turn locking slotted type:
)

Plug-in
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
64.4

128.8
115
(5.5)

96.7
(77.1)

Plug-in
12 B 12 B 12 B 12 B 12 B

5.5
39.6
(Lead wire length)
0.6 m, 1.5 m, 3 m

8.8
3.9
(6)
(9.3)

Manifold Exploded View


(17.9)

18 (A, B port: ø12) 4 x M5 Mounting hole

Type 50, 51, 52


42.7 L2 1.5
(Fitting for the type with P/E
18 (5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

(Station 1) (Station n)

Connector Connecting Base


One-touch fitting
[1(P), 3/5(E) port]
2

Applicable tube O.D.: ø12, ø1/2"


82.7

1 P 1 P
2 B2 B2 B2 B2 B
56.6
11.1

3/5 E 3/5 E
8.7
35.2

31.6

4 A4 A4 A4 A4 A

Plug-in
14.2

(For DIN rail

(Pitch)
(10)

(21.7)
mounting)

Manifold Exploded View


61.5 20.5 P = 19
Type 10, 11, 12
(14.3)

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.
One-touch Fittings/


: These figures show the “SS5Y7-10L1:-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

130
Plug-in Connector Connecting Base
Lead Wire
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12 L1 1 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top
ported type.
/ 4 ) 0 1 6 2 *
/ Series 0 Valve stations
3 SY3000 (L1:) (L3:)
5 SY5000 Symbol Stations Note Symbol Stations Note
7 SY7000 02 2 stations 02 2 stations
Double wiring
1 Double wiring
1
4 Number of cores 16 16 stations 04 4 stations
(Lead wire) ) Lead wire length 02 2 stations Specified layout
2 02 2 stations Specified layout
2
L1 34 cores 1 0.6 m (Available up to (Available up to
L2 17 cores 2 1.5 m 24 24 stations 32 solenoids) 08 8 stations 8 solenoids)
L3 9 cores 3 3m (L2:)
Symbol Stations Note
1 P, E port entry 02 2 stations
U
1 U side (2 to 10 stations) Double wiring
1
D
1 D side (2 to 10 stations) 08 8 stations
B Both sides (2 to 24 stations) 02 2 stations Specified layout
2

1: 6 For type “S”, supply/exhaust block (Available up to


assembly with built-in silencer, choose U or 16 16 stations 16 solenoids)
D for P port entry.
1: Double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an unused control
How to Order Manifold Assembly signal. If this is not desired, order with a specified layout.

2: Specified layout: Indicate the wiring specifications on the manifold
specification sheet. (Note that 2-position double, 3-position and
Example (SS5Y3-12L11-:) 4-position valves cannot be used where single wiring has been
specified.)
2-position double (24 VDC)
: This also includes the number of blanking plate assembly.
SY3230-5U1-C6 (1 set)
2-position single (24 VDC)
3-position closed
6 SUP/EXH block assembly
SY3130-5U1-C6 (3 sets) center (24 VDC) Nil Internal pilot
SY3330-5U1-C6 (1 set) S Internal pilot, Built-in silencer
R External pilot

: For built-in silencer type, P and E ports are available on U and D sides.
3/5(E) port is plugged. The silencer exhaust port is located on the
opposite side of P, E port entry. (Example: When the P, E port entry is
D side, the silencer exhaust port is U side.)

: When the built-in silencer type is used, keep the exhaust port from
e coming in direct contact with water or other liquids.
U sid
ns
a tio
St
3
1
2 2 P, E port size (One-touch fittings)
e
D sid Symbol SY3000 SY5000 SY7000
Manifold base
(5 stations) Nil ø8 ø10 ø12
SS5Y3-12L11-05D
N ø5/16" ø3/8" ø1/2"

: For N, sizes are in inches.
SS5Y3-12L11-05D ··· 1 set (Type 12 5-station manifold base part no.)

SY3130-5U1-C6 ······· 3 sets (2-position single part no.)

SY3230-5U1-C6 ······· 1 set (2-position double part no.) * Mounting

SY3330-5U1-C6 ······· 1 set (3-position closed center part no.) Nil Direct mounting
The asterisk denotes the symbol for assembly. D DIN rail mounting (With DIN rail)
Prefix it to the part numbers of the valve etc. D0 DIN rail mounting (Without DIN rail)
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE D3 For 3 stations
Specify a longer rail than
···

···

sUnder the manifold part number, state the valves to be mounted in order the standard length.
from the 1st station as shown in the figure above. If the arrangement D24 For 24 stations
becomes complicated, specify on a manifold specification sheet.
: Refer to page 271 for the fixation of DIN rail mounting type manifold.

131
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the high 01 1/8 SY5000
pressure type. 02 1/4 SY7000

Metal Base
4 Type of actuation One-touch fitting (Metric)
1
2-position
Single 2 Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double Nil Standard C2 ø2 ) — —
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
4 3-position Exhaust center
: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
5 Pressure center type when the valve is continuously C6 ø6 ) ) )
A
1 N.C./N.C. energized for long periods of time. C8 ø8 — ) )
4-position
: Be careful of the energizing time when the C10 ø10 — — )
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page C12 ø12 — — )
C
1 N.C./N.O.
268 for details.

1: Only rubber seal type is available for the One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve.
* Rated voltage A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


Symbol

5 24 VDC N1 ø1/8" ) — —
6 12 VDC N3 ø5/32" ) ) —
) Seal type N7 ø1/4" ) ) )
0 Rubber seal N9 ø5/16" — ) )
1 Metal seal N11 ø3/8" — — )
- Light/surge voltage suppressor
and common specification

Connector Connecting Base


Surge voltage Common
0 Pilot type Symbol With light
suppressor specification  Thread type
Nil Internal pilot Nil — — Nil Rc
R External pilot R — Non-polar F G
U ) N NPT
S — Positive T NPTF
) common
Z )
: Only Nil is available for M5.
1 Back pressure check valve NS — Negative
(Built-in valve type) NZ ) common

Plug-in
Nil None
H Built-in

: Only “Z” and “NZ” types are available for with
the power saving circuit.
 Type of mounting screw
Nil Round head combination screw

: Only rubber seal type. Manifold installed type


B Hexagon socket head cap screw

Manifold Exploded View


is available if the back pressure check valve
is required for a valve with metal seal. Refer  Manual override K Round head combination screw (Falling-out-prevention type)
Type 10, 11, 12
to page 256 for Ordering Example. However, Nil: D: H Hexagon socket head cap screw (Falling-out-prevention type)
it is not recommended to use the built-in Non-locking Push-turn
: For “K” and “H”, the valve body cover has a
valve type and the manifold installed type at push type locking slotted drop prevention construction to stop the
the same time because it will reduce the flow. type mounting screws from falling out when the

: The built-in valve type back pressure check valve is removed for maintenance etc.
valve is not available for the 3-position type
: When ordering a valve individually, the
and the SY7000. base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
Plug Assembly Part No.

E: F:
One-touch Fittings/

separately if it is needed for maintenance


Push-turn Slide locking service.
locking lever type Refer to page 244 for part numbers of the
type base gasket and mounting screw.

: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
132
Series SY3000/5000/7000

Electrical Wiring Specifications


Lead wire Electrical characteristics
Item Property
If alignment is not specified, the internal Conductor resistance
34 cores Lead wire 143 or less
wiring is double wiring (connected to 7/km, 20nC
2
0.18 mm x 34 cores SOL. a and SOL. b) regardless of
Voltage limit
number of stations, valve and option 2000
34 1 2
V, 1 minute, AC
33 11 3 types.
32 26 12 4 Insulation resistance
25 17 13 10 or more
31 21 18 5 M7/km, 20nC
30 24 14 6
20 19
29 23 15 7

: Cannot be used for movable wiring.
22 16
28 8 The minimum bending radius of the
27 10 9
Sheath O.D. cable is 55 mm.
Approx. ø8.8

Lead Printed mark


wire (Both sides)
Lead wire no. Polarity color Type Color
SOL.a
1 (−) (+) Red
Station 1 SOL.b Orange
2 (−) (+) Black
SOL.a
3 (−) (+) Light Red
Station 2 SOL.b gray
4 (−) (+) Black
SOL.a
5 (−) (+) Red
Station 3 SOL.b White
6 (−) (+) Black
SOL.a
7 (−) (+) Red
Station 4 SOL.b Yellow
8 (−) (+) Black
SOL.a
9 (−) (+) Red
Station 5 SOL.b Pink
10 (−) (+) Black
SOL.a
11 (−) (+) Red
Station 6 SOL.b Orange
12 (−) (+) Black
SOL.a
13 (−) (+) Light Red
Station 7 SOL.b
14 (−) (+) gray Black
SOL.a
15 (−) (+) Red
Station 8 SOL.b White
16 (−) (+) Black
SOL.a
17 (−) (+) Red
Station 9 SOL.b Yellow
18 (−) (+) Black
SOL.a
19 (−) (+) Red
Station 10 SOL.b Pink
20 (−) (+) Black
SOL.a
21 (−) (+) Red
Station 11 SOL.b Orange
22 (−) (+) Black
SOL.a
23 (−) (+) Light Red
Station 12 SOL.b
24 (−) (+) gray Black
SOL.a
25 (−) (+) Red
Station 13 SOL.b White
26 (−) (+) Black
SOL.a
27 (−) (+) Red
Station 14 SOL.b Yellow
28 (−) (+) Black
SOL.a
29 (−) (+) Red
Station 15 SOL.b Pink
30 (−) (+) Black
SOL.a 31 (−) (+) Red
Station 16 SOL.b 32 (−) Orange
(+) Black
COM.
33 (+) (−) Light Red
COM. gray
34 (+) (−) Black
Positive Negative
common common

: For negative common specification, a valve for negative


common or a valve without polarity should be used.

Specified Layout
Mixed wiring of single and double wiring can be specified on the
manifold specification. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 32 or less. 1 solenoid is required for 2-position
single, and 2 solenoids for 2-position double, 3-position and
4-position.

133
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Electrical Wiring Specifications
Lead wire Electrical characteristics
Item Property

Sub-plate
Conductor resistance
143 or less
17 cores Lead wire 9 cores Lead wire 7/km, 20nC
0.18 mm2 x 17 cores 0.18 mm2 x 9 cores
Voltage limit
2000
1 V, 1 minute, AC

Plug-in
17 2
1
16 13 8 9 3 9 2 Insulation resistance
10 or more
15 12 10 4
8 5 3 M7/km, 20nC
11 7 4
14 5 6
7 6
: Cannot be used for movable wiring.
: Cannot be used for movable wiring.
The minimum bending radius of the cable The minimum bending radius of the cable
is 45 mm. is 40 mm.
Sheath O.D. Sheath O.D.
ø6.8 Lead Printed mark ø6.3 Lead Printed mark
wire (Both sides) wire (Both sides)
Lead wire no. Polarity color Lead wire no. Polarity color Type Color
Type Color

Metal Base
SOL.a SOL.a
1 (−) (+) Red 1 (−) (+) Red
Station 1 SOL.b Orange Station 1 SOL.b Orange
2 (−) (+) Black 2 (−) (+) Black
SOL.a SOL.a
3 (−) (+) Light Red 3 (−) (+) Light Red
Station 2 SOL.b Station 2 SOL.b
4 (−) (+) gray Black 4 (−) (+) gray Black

Plug-in
SOL.a SOL.a
5 (−) (+) Red 5 (−) (+) Red
Station 3 SOL.b White Station 3 SOL.b White
6 (−) (+) Black 6 (−) (+) Black
SOL.a SOL.a
7 (−) (+) Red 7 (−) (+) Red
Station 4 SOL.b Yellow Station 4 SOL.b Yellow
8 (−) (+) Black 8 (−) (+) Black
SOL.a COM.
9 (−) (+) Red 9 (+) (−) Pink Red

Manifold Exploded View


Station 5 SOL.b Pink
10 (−) (+) Black Positive Negative

Type 50, 51, 52


SOL.a Red common common
11 (−) (+)
Station 6 SOL.b Orange
12 (−) (+) Black
SOL.a Red
13 (−) (+) Light
Station 7 SOL.b gray
14 (−) (+) Black
SOL.a Red
15 (−) (+)
Station 8 SOL.b White
16 (−) (+) Black
COM. Yellow Red
17 (+) (−)

Connector Connecting Base


Positive Negative
common common


: For negative common specification, a valve for negative
common or a valve without polarity should be used.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

134
Plug-in Connector Connecting Base
Type 10
Side Ported Circular Connector

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 5 10 M 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type. / 4 ) 0 1 6 2
/ Series ) Valve stations 0 P, E port entry
3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring
1
···

7
···

SY7000 B Both sides (2 to 24 stations)


12 12 stations
02 2 stations
4 Type Specified layout
2 1 SUP/EXH block assembly
···

···

Side ported (Available up to 24 solenoids)


10 24 24 stations Nil Internal pilot
11 Bottom ported
1
1: Double wiring: 2-position single, double, 3-position and S Internal pilot, Built-in silencer

1: The SY5000 manifold base is 4-position valves can be used on all manifold stations. R External pilot
used for the bottom ported of Use of a 2-position single solenoid will result in an
: 3/5(E) port is plugged for the built-in silencer
the SY3000. When ordering, unused control signal. If this is not desired, order with type.
refer to “Plug-in Mixed a specified layout.
: When the built-in silencer type is used, keep
Mounting Type Manifold”
2: Specified layout: Indicate the wiring specifications on the exhaust port from coming in direct contact
(from page 213). the manifold specification sheet. (Note that 2-position with water or other liquids.
double, 3-position and 4-position valves cannot be
used where single wiring has been specified.)

: This also includes the number of blanking plate
Refer to the page on the right for .
assembly.

How to Order Manifold Assembly 2 Mounting and Option


Option
Symbol Mounting
Name plate Station number
Example (SS5Y3-10M-:) Nil — —
2-position double (24 VDC) Direct
AA mounting ) )
SY3200-5U1 (1 set) BA ) —
2-position single (24 VDC)
3-position closed D: — —
SY3100-5U1 (3 sets) center (24 VDC) DIN rail
A: mounting ) )
SY3300-5U1 (1 set)
B: ) —

: Enter the number of stations inside : when it
is larger than the number of valve stations.
(Refer to “DIN Rail Option” below.)

: Only direct mounting is available for Type 11
(Bottom ported).
ide
: Refer to page 271 for the fixation of DIN rail
s
Us mounting type manifold.
at ion
St
3
2 DIN Rail Option
1
e Nil Direct mounting
D sid
Manifold base 0 Without DIN rail (with bracket)
(5 stations) 3 For 3 stations
Specify a longer rail than the
···

SS5Y3-10M-05D-C6
···

total length of specified stations.


SS5Y3-10M-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) 24 For 24 stations

SY3100-5U1 ··············· 3 sets (2-position single part no.)

SY3200-5U1 ··············· 1 set (2-position double part no.)

SY3300-5U1 ··············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 142.


In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.

135
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
6 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Metal Base
Straight
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —

Manifold Exploded View


Downward

Type 50, 51, 52


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —
L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class  (Mark: )
136
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the high slotted
pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O.
page 268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC
6 12 VDC
 Type of mounting screw
) Seal type Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal
- Light/surge voltage suppressor K Round head combination screw (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw (Falling-out-prevention type)
Surge voltage Common
: For “K” and “H”, the valve body cover has a
Symbol With light
0 Pilot type suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
Nil Internal pilot Nil — —
valve is removed for maintenance etc.
R External pilot R — Non-polar

: When ordering a valve individually, the
U ) base gasket is not included.
S — Positive Since the base gasket is attached to the
) common
Z ) manifold, please order the base gasket
1 Back pressure check valve NS — Negative separately if it is needed for maintenance
(Built-in valve type) common service.
NZ )
Refer to page 244 for part numbers of the
Nil None
: Only “Z” and “NZ” types are available for with base gasket and mounting screw.
H Built-in the power saving circuit.
: “B” and “H” cannot be selected for the

: Only rubber seal type. Manifold installed type individual SUP/EXH spacer assembly,
is available if the back pressure check valve interface regulator or double check spacer
is required for a valve with metal seal. Refer assembly with residual pressure release
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
137
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base Circular Connector

C2
U
SS5Y3-10M- Stations D - C3, N1
C4, N3 (D)
B C6, N7
D side U side

Sub-plate
(L5) L1 Manual override
1

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)

Plug-in
DIN rail (Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
67.8

60.5

Metal Base
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B
21.9

1.7

4.6
)
(4.9)

C6: 3.6
N7: 7.4

Plug-in
4 x M4 Mounting hole
18 (
18 (Fitting for the type with P/E ports on the U and/or D sides)

43 L2 1.5
(5.3) (L4)

Manifold Exploded View


(DIN rail mounting hole pitch: 12.5)

Type 50, 51, 52


(L3)

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] (Station 1)---(Station n) Applicable tube O.D.: ø2
Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
: ø4, ø5/32"
Circular connector cable assembly : ø6, ø1/4"

Connector Connecting Base


1 P 1 P
AXT100-MC26-015: 1.5 m 63.1
AXT100-MC26-030: 3 m
13.6
10.6

56.6

AXT100-MC26-050: 5 m 3/5 E 2 B2 B2 B2 B2 B 3/5 E


40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail

Circular connector (26 pins)


(7.5)

mounting)

(Pitch)
(11.8)

made by CONINVERS GmbH 54.8 15.5 (17.8)


P = 10.5

Plug-in
Manifold Exploded View

1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10M-05D-C6”. Type 10, 11, 12

: Refer to page 210 for dimensions of A or B port top-ported type. Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

138
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Circular Connector

U C4, N3
SS5Y5-10M- Stations D - C6, N7 (D)
B C8, N9 D side U side
Manual override
1
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
64.4

81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

18

18 4 x M5 Mounting hole
42.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Circular connector cable assembly (L3)
AXT100-MC26-015: 1.5 m
AXT100-MC26-030: 3 m
AXT100-MC26-050: 5 m
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n)
: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

1 P 1 P
14.1

73.2
2 B2 B2 B2 B2 B
56.6
12.4

8.7

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
(For DIN rail
mounting)
(7.5)

Circular connector (26 pins) (Pitch)


(11.8)

made by CONINVERS GmbH 56.5 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10M-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

139
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base Circular Connector

C6, N7
U
SS5Y7-10M- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side

Manual override
1
(L5) L1
(
Push-turn locking slotted type:
)

Plug-in
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor) 2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
64.4

128.8
115
(5.5)

96.7
(77.1)

Plug-in
5.5
12 B 12 B 12 B 12 B 12 B
39.6

8.8
3.9
(6)

18
(9.3)

Manifold Exploded View


(17.9)

(A, B port: ø12) 4 x M5 Mounting hole


18

Type 50, 51, 52


42.7 L2 1.5 (Fitting for the type with P/E ports
(5.3) (L4) on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
Circular connector cable assembly

Connector Connecting Base


[4(A), 2(B) port]
AXT100-MC26-015: 1.5 m
Applicable tube O.D.: ø6, ø1/4"
AXT100-MC26-030: 3 m (Station 1) (Station n)
: ø8, ø5/16"
AXT100-MC26-050: 5 m
: ø10, ø3/8"
: ø12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
2
82.7

1 P 1 P
2 B2 B2 B2 B2 B

Plug-in
56.6

E E
11.1

3/5 3/5
8.7
35.2

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


14.2

Type 10, 11, 12


(For DIN rail

(Pitch)
(10)

(21.7)
mounting)

Circular connector (26 pins) 61.5 20.5 P = 19


Made by CONINVERS GmbH
(14.3)


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.
One-touch Fittings/


: These figures show the “SS5Y7-10M-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

140
Plug-in Connector Connecting Base
Circular Connector
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12M 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top
ported type.
/ 4 ) 0 1 6
/ Series 4 Valve stations ) P, E port entry
3 SY3000 Symbol Stations Note U
1 U side (2 to 10 stations)
5 SY5000 02 2 stations D
1 D side (2 to 10 stations)
Double wiring
1
···

7 B
···

SY7000 Both sides (2 to 24 stations)


12 12 stations
1: 0 For type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U or
Specified layout
2 D for P port entry.
···

···

(Available up to 24 solenoids)
24 24 stations

1: Double wiring: 2-position single, double,
3-position and 4-position valves can be
used on all manifold stations.
Use of a 2-position single solenoid will
0 SUP/EXH block assembly
result in an unused control signal. If this is
Nil Internal pilot
not desired, order with a specified layout. S Internal pilot, Built-in silencer

2: Specified layout: Indicate the wiring R External pilot
specifications on the manifold specification
: For built-in silencer type, P and E ports are
sheet. (Note that 2-position double, available on U and D sides. 3/5(E) port is
3-position and 4-position valves cannot be plugged. The silencer exhaust port is located
used where single wiring has been on the opposite side of P, E port entry.
specified.) (Example: When the P, E port entry is D side,

: This also includes the number of blanking the silencer exhaust port is U side.)
plate assembly.
: When the built-in silencer type is used, keep
the exhaust port from coming in direct contact
with water or other liquids.
How to Order Manifold Assembly

Example (SS5Y3-12M-:)
2-position double (24 VDC)
2-position single (24 VDC) SY3230-5U1-C6 (1 set)
1 P, E port size (One-touch fittings)
SY3130-5U1-C6 (3 sets) Symbol SY3000 SY5000 SY7000
3-position closed
center (24 VDC)
Nil ø8 ø10 ø12
SY3330-5U1-C6 (1 set)
N ø5/16" ø3/8" ø1/2"

: For N, sizes are in inches.

ide
Us 6 Mounting
ns
atio Nil Direct mounting
St
3 DIN rail mounting
2 D (With DIN rail)
1
ide DIN rail mounting
Ds D0 (Without DIN rail)
Manifold base (5 stations)
D3 For 3 stations
SS5Y3-12M-05D Specify a longer rail than
···

···

the standard length.


D24 For 24 stations
SS5Y3-12M-05D ········ 1 set (Type 12 5-station manifold base part no.)

SY3130-5U1-C6 ········ 3 sets (2-position single part no.)

: Refer to page 271 for the fixation of DIN rail
mounting type manifold.

SY3230-5U1-C6 ········ 1 set (2-position double part no.)

SY3330-5U1-C6 ········ 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
sUnder the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

141
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

Metal Base
4 Type of actuation One-touch fitting (Metric)
1
2-position
Single 2 Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double Nil Standard C2 ø2 ) — —
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
4 3-position Exhaust center C4 ø4 ) ) —

Plug-in

: Be sure to select the power saving circuit
5 Pressure center type when the valve is continuously C6 ø6 ) ) )
A
1 N.C./N.C. energized for long periods of time. C8 ø8 — ) )
4-position
: Be careful of the energizing time when the C10 ø10 — — )
B
1 dual 3-port N.O./N.O.
power saving circuit is selected. Refer to C12 ø12 — — )
C
1 N.C./N.O.
page 268 for details.

1: Only rubber seal is available for the One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve. * Rated voltage A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


Symbol
5 24 VDC N1 ø1/8" ) — —
6 12 VDC N3 ø5/32" ) ) —
) Seal type N7 ø1/4" ) ) )
0 Rubber seal
N9 ø5/16" — ) )
N11 ø3/8" — — )
1 Metal seal - Light/surge voltage suppressor
and common specification

Connector Connecting Base


Surge voltage Common
0 Pilot type
Symbol With light
suppressor specification  Thread type
Nil — — Nil Rc
Nil Internal pilot
R — Non-polar F G
R External pilot
U ) N NPT
S — Positive T NPTF
) common
Z )
Only Nil is available for M5.
1 Back pressure check valve NS — Negative
(Built-in valve type) NZ ) common

Plug-in
Nil None
: Only “Z” and “NZ” types are available for with
H Built-in the power saving circuit.
 Type of mounting screw
Nil Round head combination screw

: Only rubber seal type. Manifold installed type


B Hexagon socket head cap screw

Manifold Exploded View


is available if the back pressure check valve
is required for a valve with metal seal. Refer  Manual override K Round head combination screw (Falling-out-prevention type)
Type 10, 11, 12
to page 256 for Ordering Example. However, Nil: D: H Hexagon socket head cap screw (Falling-out-prevention type)
it is not recommended to use the built-in Non-locking Push-turn
: For “K” and “H”, the valve body cover has a
valve type and the manifold installed type at push type locking drop prevention construction to stop the
the same time because it will reduce the flow. slotted mounting screws from falling out when the

: The built-in valve type back pressure check type valve is removed for maintenance etc.
valve is not available for the 3-position type
: When ordering a valve individually, the
and the SY7000. base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
Plug Assembly Part No.

E: F:
One-touch Fittings/

separately if it is needed for maintenance


Push-turn Slide locking service.
locking type Refer to page 244 for part numbers of the
lever base gasket and mounting screw.
type
: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
142
Series SY3000/5000/7000

Electrical Wiring Specifications Cable Assembly


015
Circular connector
AXT100-MC26- 030
If alignment is not specified, the 050
internal wiring is double wiring Cable
 : (connected to SOL. a and SOL. 0.3 mm2 x 26 cores
  @
b) regardless of number of O.D. ø1.4 Lead wire color for circular
   .
stations, valve and option types. connector cable assembly
    ;
Approx. ø10 by terminal number
    = Lead Dot
   B
Terminal wire
Seal (Length) no. marking
color
8 2 >
015 1
2
3
Black
Brown
Red
None
None
None
4 Orange None
Terminal no. Polarity
5 Yellow None
SOL.a
1 (−) (+) 6 Pink None
Station 1 SOL.b
2 (−) (+) 7 Blue None
SOL.a
3 (−) (+)

L
Station 2 8 Purple White
SOL.b
4 (−) (+) 9 Gray Black
SOL.a
5 (−) (+) 10 White Black
Station 3 SOL.b
6 (−) (+)

60
11 White Red
SOL.a
7 (−) (+) 12 Yellow Red
Station 4 SOL.b
8 (−) (+) 13 Orange Red
SOL.a Plug
9 (−) (+) 14 Yellow Black
Station 5 SOL.b
10 (−) (+) 15 Pink Black
SOL.a
11 (−) (+) 16 Blue White
Station 6 SOL.b
12 (−) (+) 17 Purple None
SOL.a
13 (−) (+) 18 Gray None
Station 7 SOL.b
14 (−) (+) 19 Orange Black
SOL.a ø30
15 (−) (+) 20 Red White
Station 8 SOL.b
16 (−) (+) 21 Brown White
SOL.a 1 15
17 (−) (+) 2 14 Terminal no. 22 Pink Red
Station 9 SOL.b 17
16
24
18 (−) (+) 3 13 23 Gray Red
SOL.a 25
19 (−) (+) 18 23
Station 10 4 12 24 Black White
SOL.b
20 (−) (+) 19 26 22 25 White None
SOL.a 5
20 21
11
21 (−) (+) 26 White None
Station 11 SOL.b 6 10
22 (−) (+) 7 9
M27 female
SOL.a 8 thread
23 (−) (+) Electrical characteristics
Station 12 SOL.b
24 (−) (+) Item Property
COM.
25 (+) (−) Conductor
COM. 65 or
26 (+) (−) resistance
less
7/km, 20nC
Positive Negative
Voltage limit
common common 1000
V, 1 minute, AC
Circular connector cable assembly
Insulation
Cable Assembly part no. 5 or
resistance
length (L) 26 pins more
M7/km, 20nC

: When using a valve with no polarity, either positive common or 1.5 m AXT100-MC26-015
negative common can be used.
: The minimum bending
3m AXT100-MC26-030 radius of the circular
5m AXT100-MC26-050 connector cable is 20

Cannot be used for movable wiring. mm.

Lengths other than the above is also
Specified Layout available. Please contact SMC for details.
Mixed wiring of single and double wiring can be specified on the
manifold specification sheet. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 24 or less. 1 solenoid is required for 2-position
single, and 2 solenoids for 2-position double, 3-position and
4-position.

143
144
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralized System 2 (128 Points)

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and SS5Y 3 10 S A3N 05 U C6


209 (SY7000) for dimensions of
Type 11/Bottom ported type.
/ 4 ) 0 1 6 2 *
/ Series ) SI Unit (Number of outputs, Output polarity, 0 Valve stations
3 SY3000 Max. number of valve stations) Stations Note
5 SY5000 0 Without SI Unit 02 2 stations


7 SY7000 32 outputs
1
4, 1 to 16 stations (24 Double wiring
1
A3N stations
3), Negative common
2 16 16 stations

: For mixed mounting, refer to page 213 and


later.
1: 16 outputs can be set by switching the built-in 02 2 stations
Mixed wiring, Specified layout
2


setting switch. (Available up to 32 solenoids)

2: Ensure a match with the common specification 24 24 stations
4 Type of the valve.
1: Double wiring: 2-position single, double,
10 Side ported
3: ( ): Maximum number of stations for mixed 3-position and 4-position valves can be
11 Bottom ported
1 single and double wiring. used on all manifold stations.

1: The SY5000 manifold base is used for the


4: When using the SI Unit with 32 outputs, use Use of a 2-position single solenoid will
bottom ported of the SY3000. When the GW Unit compatible with the EX500 result in an unused control signal.
ordering, refer to “Plug-in Mixed Mounting Gateway Decentralized System 2 (128 points). If this is not desired, order with a specified
Type Manifold” (from page 213). layout.

: When mixing top ported configurations,


2: Specified layout: Indicate the wiring
select from page 158. specifications on the manifold specification
In this case, use caution as there is also sheet. (Note that 2-position double,
output on the A and B port on base side. 3-position and 4-position valves cannot be
Specify on a manifold specification sheet if used where single wiring has been
plugs are required on the A and B port on specified.)
base side.
: When the product without the SI Unit (S0) is
selected, note the maximum number of
solenoids of the SI Unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.

: This also includes the number of blanking
How to Order Manifold Assembly plate assembly.

Example 1 P, E port entry


Manifold base 2-position double U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)

6 SUP/EXH block assembly


Nil Internal pilot
S Internal pilot, Built-in silencer
1
2
R External pilot

1: 3/5(E) port is plugged for the built-in
silencer type.
de
si
U


2: When built-in silencer type is used, keep
ns
tio

the exhaust port from coming in direct


ta
S

contact with water or other liquids.


3
2
1
de
si
D

SS5Y3-10SA3N-05D-C6···1 set (Manifold base part number)



SY3200-5U1···················5 sets (2-position double part number)

: A separate GW Unit and communication cable are required.
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc. For details about the EX500 Gateway-type Serial Transmission
System, refer to the WEB catalog or the Best Pneumatics No.
sThe valve arrangement is numbered as the 1st station from the D side. 1 and the Operation Manual. For details about part numbers of
sUnder the manifold base part number, state the valves to be mounted in SI Units to be mounted, refer to page 235 in this catalog.
order from the 1st station as shown in the figure above. If the arrangement Please download the Operation Manual via SMC website,
becomes complicated, specify on the manifold specification sheet. http://www.smcworld.com

145
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
2 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side Ported Type 11/Bottom Ported Type 10/Side Ported Type 11/Bottom Ported
A, B port A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — —
LM
1 Mixed sizes ) ) ) — —
B8 ø8 — ) ) — —
B10 ø10 — — ) — —
P, E port
3 ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — —

Connector Connecting Base


LM
1 Mixed sizes ) ) ) — —

P, E port
3 ø8 ø10 ø12 ø10 ø12

1: Indicate the sizes on the manifold specification sheet.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

3: The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

Plug-in
* Mounting and Option
Option
Mounting

Manifold Exploded View


Name plate Station number
Nil — — Type 10, 11, 12
Direct
AA mounting
) )
BA ) —
D:
1 — —
DIN rail
A:
1 mounting
) )
B:
1 ) —

1: Refer to “DIN Rail Option” below.

: Select the direct mounting type for Type 11 (Bottom ported).


Plug Assembly Part No.

DIN Rail Option


One-touch Fittings/

Nil With DIN bracket, DIN rail with standard length


0 With DIN bracket, without DIN rail
3
1 With DIN bracket, DIN rail for 3 stations

24
1 With DIN bracket, DIN rail for 24 stations
Manifold Options

1: Specify a longer rail than the length of valve stations.

: If the DIN rail must be mounted without an SI Unit, select “D0” and order
the DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
Refer to page 249 for the DIN rail part number.

: Refer to page 271 for the fixation of DIN rail mounting type manifold.

Protective class
class  (Mark: )

146
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil D
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push locking

1: Select the metal seal type for high pressure (slotted)
type.

4 Type of actuation
1 Single E F
2
2-position
Double 2 Coil type Push-turn Slide locking
3 Closed center Nil Standard locking (manual)
4 3-position Exhaust center
T
With power saving circuit (manual)
5 Pressure center (Continuous duty type)
1
2
A
1 N.C./N.C.
1: Be sure to select the power saving circuit
4-position dual
B
1 3-port valve
N.O./N.O. type when the valve is continuously
C
1 N.C./N.O. energized for long periods of time.

2: Be careful of the energizing time when the
: Refer to page 31 for with the safety slide

1: Select the rubber seal type for the 4-position locking manual override.
dual 3-port valve. power saving circuit is selected. For details,
refer to page 268.

 Type of mounting screw


) Seal type Nil
0 Rubber seal * Rated voltage B
Round head combination screw
Hexagon socket head cap screw
1 Metal seal 5 24 VDC
Round head combination screw
K (Falling-out-prevention type)
1
Hexagon socket head cap screw
H
0 Pilot type - Light/surge voltage suppressor (Falling-out-prevention type)
1

Nil Internal pilot and common specification


1: For “K” and “H”, the valve body cover has a
Surge voltage Common drop prevention construction to stop the
R External pilot With light mounting screws from falling out when the
suppressor specification
valve is removed for maintenance etc.
R —
: When ordering a valve individually, the
Non-polar
U ) base gasket is not included.
1 Back pressure check valve NS —
)
Negative Since the base gasket is attached to the
Nil None NZ ) common manifold, please order the base gasket
H
1 Built-in separately if it is needed for maintenance

: Select “NZ” for with the power saving circuit. service.

1: Select the rubber seal type when the back Refer to page 244 for part numbers of the
pressure check valve is built-in. Manifold base gasket and mounting screw.
installed type is available if the back
: Select “Nil” or “K” for the optional individual
pressure check valve is required for a valve SUP/EXH spacer assembly, interface
with metal seal. For ordering example, refer regulator or double check spacer assembly
to page 256. However, it is not with residual pressure release valve.
recommended to use the built-in valve type
and the manifold installed type at the same
time because it will reduce the flow.

: Select “Nil” for 3-position type and the


SY7000.

Protective class
class  (Mark: )

147
Plug-in Connector Connecting Base Series SY3000/5000/7000

Type 10/Side Ported

Valve
Plug-in
Dimensions: Series SY3000 Connector Connecting Base EX500 (128 Points)

U C2
SS5Y3-10SA3N- Stations DB -C3, N1
C4, N3 (D)
C6, N7

Sub-plate
D side U side

Light/surge voltage suppressor Manual override


1
(L5) L1 4(A) port side: Blue (for rubber seal)

Plug-in
: Gray (for metal seal)
2(B) port side: Yellow

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
80.2

60.5

Metal Base
(40.9)
12 B 12 B 12 B 12 B 12 B
21.2

4.6

4.6
1.7
)
C6: 3.6
N7: 7.4

Plug-in
(4.9)

4 x M4 Mounting hole
SI Unit
(

L2 1.5 (Fitting for the type with P/E ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)

Manifold Exploded View


(L3)

Type 50, 51, 52


One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø8, ø5/16"
[4(A), 2(B) port]
(Station 1) (Station n)
M12 Applicable tube O.D.: ø2
: ø3.2, ø1/8"

Connector Connecting Base


: ø4, ø5/32"
: ø6, ø1/4"
OUT
1 P 1 P
76.7
67.2

10.6
13.6

63.1

IN
56.6
46.2

3/5 E 3/5 E
(11.8)

2 B2 B2 B2 B2 B
40.2
25.6

21.6

4 A4 A4 A4 A4 A
18

Plug-in
M12 11.3 (Pitch)
(7.5)

46.5 15.5 P = 10.5 (17.8)

Manifold Exploded View


Type 10, 11, 12


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10SA3N-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.

L: Dimensions n: Stations
One-touch Fittings/

L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
Manifold Options

L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5

L n 17 18 19 20 21 22 23 24
L1 261.2 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 220.5 231 241.5 252 262.5 273 283.5 294
L3 285.5 298 310.5 323 335.5 348 348 360.5
L4 275 287.5 300 312.5 325 337.5 337.5 350
L5 12 13 14 15 16 17 12 13
148
Series SY3000/5000/7000

Plug-in Type 10/Side Ported


Dimensions: Series SY5000 Connector Connecting Base EX500 (128 Points)

U C4, N3
SS5Y5-10SA3N- Stations DB -C6, N7 (D)
C8, N9

D side U side
Light/surge voltage suppressor Manual override
1
(L5) L1 4(A) port side: Blue (for rubber seal)
: Gray (for metal seal)
2(B) port side: Yellow

(5.5)
(8)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
101

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B

10.9
0.4

4.7
(5.9)
(8.3)

SI Unit
34.2 L2 1.5
(5.3) (L4) 4 x M5 Mounting hole
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E ports on the U and/or D sides)
(L3)

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø10, ø3/8" (Station 1) (Station n) [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
M12
: ø6, ø1/4"
: ø8, ø5/16"

OUT
14.1
76.7

1 P 1 P
73.2
67.2

IN 2 B2 B2 B2 B2 B
56.6
46.2

(11.8)

3/5 3/5
33.4

E E
29.1
25.6

4 A4 A4 A4 A4 A
8.7
12.4

11.3 (Pitch)
(7.5)

M12 48.2 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10SA3N-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14

L n 17 18 19 20 21 22 23 24
L1 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 320 336 352 368 384 400 416 432
L3 385.5 410.5 423 435.5 448 473 485.5 498
L4 375 400 412.5 425 437.5 462.5 475 487.5
L5 12.5 17 15 13.5 11.5 16 14.5 12.5
149
Plug-in Connector Connecting Base Series SY3000/5000/7000

Type 10/Side Ported

Valve
Plug-in
Dimensions: Series SY7000 Connector Connecting Base EX500 (128 Points)

U C6, N7
SS5Y7-10SA3N- Stations DB -C8, N9
C10, N11 (D)
C12

Sub-plate
D side U side

Light/surge voltage suppressor Manual override


1
(L5) L1 4(A) port side: Blue (for rubber seal)

Plug-in
: Gray (for metal seal)
2(B) port side: Yellow

(8)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
101.4

Metal Base
128.8
115
96.7
(5.5)

(77.1)
5.5
12 B 12 B 12 B 12 B 12 B

Plug-in
15

8.8
3.9
(6)
(N13: 20.4)

SI Unit
(9.3)

(17.9)

(A, B port: ø12) 4 x M5 Mounting hole

Manifold Exploded View


34.4 L2 1.5

Type 50, 51, 52


(5.3) (L4) (Fitting for the type with P/E ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]

Connector Connecting Base


Applicable tube O.D.: ø12, ø1/2" (Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
M12 : ø10, ø3/8"
: ø12
2

OUT
11.1

82.7

1 P 1 P
76.7

S
2 B2 B2 B2 B2 B
67.2

IN
56.6
46.2

(14.3)

3/5 E 3/5 E
35.2

31.6

4 A4 A4 A4 A4 A

Plug-in
25.6

8.7
14.2

Manifold Exploded View


11.3 (Pitch)
(10)

M12 53.2 20.5 P = 19 21.7 Type 10, 11, 12


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10SA3N-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Plug Assembly Part No.

L: Dimensions n: Stations
One-touch Fittings/

L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
Manifold Options

L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5

L n 17 18 19 20 21 22 23 24
L1 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 379 398 417 436 455 474 493 512
L3 448 473 485.5 510.5 523 548 560.5 585.5
L4 437.5 462.5 475 500 512.5 537.5 550 575
L5 14 17 14 17 13.5 16.5 13.5 16.5
150
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralized System (64 Points)

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 3 10 S A2 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type. / 4 ) 0 1 6 2 *
/ Series ) SI Unit (Number of outputs, Output polarity, 0 Valve stations
3 SY3000 Max. number of valve stations) Stations Note
5 SY5000 0 Without SI Unit 02 2 stations
Double wiring
1

···
7

···
SY7000 16 outputs,

: For mixed mounting, refer to page 213 and A2 Positive common


1, 08 8 stations
later. 1 to 18 stations (16 stations)
2 02 2 stations
Specified layout
2

···

···
16 outputs, (Available up to 16 solenoids)
A2N Negative common
1, 16 16 stations
4 Type 1 to 18 stations (16 stations)
2
1: Double wiring: 2-position single, double,
10 Side ported
1: Ensure a match with the common 3-position and 4-position valves can be
11 Bottom ported
1 specification of the valve to be used. used on all manifold stations.

1: The SY5000 manifold base is used for the


2: ( ): Maximum number of stations for mixed Use of a 2-position single solenoid will
bottom ported of the SY3000. When single and double wiring. result in an unused control signal. If this is
ordering, refer to “Plug-in Mixed Mounting not desired, order with a specified layout.
Type Manifold” (from page 213).
2: Specified layout: Indicate the wiring

: When mixing top ported configurations, specifications on the manifold specification


select from page 160. In this case, use sheet. (Note that 2-position double,
caution as there is also output on the A and 3-position and 4-position valves cannot be
B port on base side. Specify on a manifold used where single wiring has been
specification sheet if plugs are required on specified.)
the A and B port on base side.
: When the product without the SI Unit (S0) is
selected, note the maximum number of
solenoids of the SI Unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly
: This also includes the number of blanking
plate assembly.

Example (SS5Y3-10SA2-:)
2-position double (24 VDC) 1 P, E port entry
2-position single (24 VDC) SY3200-5U1 (1 set) U U side (2 to 10 stations)
SY3100-5U1 (3 sets) D D side (2 to 10 stations)
3-position closed
center (24 VDC) B Both sides (2 to 16 stations)
SY3300-5U1 (1 set)

6 SUP/EXH block assembly


Nil Internal pilot
S Internal pilot, Built-in silencer
R External pilot
ide
Us
: 3/5(E) port is plugged for the built-in silencer
type.
s
n
tio


: When the built-in silencer type is used, keep
ta
S

3 the exhaust port from coming in direct


2 contact with water or other liquids.
1
ide
Ds
Manifold base (5 stations)
SS5Y3-10SA2-05D-C6

SS5Y3-10SA2-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)



SY3100-5U1···················· 3 sets (2-position single part no.)

SY3200-5U1···················· 1 set (2-position double part no.)

SY3300-5U1···················· 1 set (3-position closed center part no.)
: A separate GW Unit and communication cable are required.
The asterisk denotes the symbol for assembly. For details about the EX500 Gateway-type Serial
Prefix it to the part numbers of the valve etc. Transmission System, refer to the WEB catalog or the
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE Best Pneumatics No. 1 and the Operation Manual. For
s Under the manifold part number, state the valves to be mounted in order details about part numbers of SI Units to be mounted, refer
from the 1st station as shown in the figure above. If the arrangement to page 236 in this catalog. Please download the Operation
becomes complicated, specify on a manifold specification sheet. Manual via SMC website, http://www.smcworld.com

151
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
2 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side Ported Type 11/Bottom Ported Type 10/Side Ported Type 11/Bottom Ported
A, B port A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — —
LM
1 Mixed sizes ) ) ) — —
B8 ø8 — ) ) — —
B10 ø10 — — ) — — P, E port
3
ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


LM
1 Mixed sizes ) ) ) — —

P, E port
3
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

3: The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

Plug-in
* Mounting and Option
Option
Mounting

Manifold Exploded View


Name plate Station number
Nil — — Type 10, 11, 12
Direct
AA mounting
) )
BA ) —
D:
1 — —
DIN rail
A:
1 mounting
) )
B:
1 ) —

1: Refer to “DIN Rail Option” below.

: Select the direct mounting type for Type 11 (Bottom ported).


Plug Assembly Part No.

DIN Rail Option


One-touch Fittings/

Nil With DIN bracket, DIN rail with standard length


0 With DIN bracket, without DIN rail
3
1 With DIN bracket, DIN rail for 3 stations

16
1 With DIN bracket, DIN rail for 16 stations
Manifold Options

1: Specify a longer rail than the length of valve stations.

: If the DIN rail must be mounted without an SI Unit, select “D0” and order
the DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
Refer to page 249 for the DIN rail part number.

: Refer to page 271 for the fixation of DIN rail mounting type manifold.

Protective class
class  (Mark: )

152
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port N.O./N.O.
power saving circuit is selected. Refer to page
C
1 N.C./N.O.
268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC
) Seal type  Type of mounting screw
Nil Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal - Light/surge voltage suppressor K Round head combination screw (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw (Falling-out-prevention type)
Surge voltage Common
: For “K” and “H”, the valve body cover has a
Symbol With light
0 Pilot type suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
Nil Internal pilot R —
Non-polar
U ) valve is removed for maintenance etc.
R External pilot
: When ordering a valve individually, the
S — Positive
base gasket is not included.
)
Z ) common
Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
1 Back pressure check valve NZ ) common separately if it is needed for maintenance
(Built-in valve type)
: Only “Z” and “NZ” are available for with the service.
power saving circuit. Select a valve from R, Refer to page 244 for part numbers of the
Nil None
U, S or Z when the SI Unit specification is A2 base gasket and mounting screw.
H Built-in
: “B” and “H” cannot be selected for the
(positive common). Select a valve from R, U,

: Only rubber seal type. Manifold installed type NS or NZ when the SI Unit specification is individual SUP/EXH spacer assembly,
is available if the back pressure check valve A2N (negative common). interface regulator or double check spacer
is required for a valve with metal seal. Refer assembly with residual pressure release
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
153
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX500 (64 Points)

C2
U
SS5Y3-10SA2- Stations D - C3, N1
C4, N3 (D)
B C6, N7

Sub-plate
D side U side Manual override
1

DIN rail holding screw


(L5) L1
(
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor) 2(B) port side : Yellow
SI Unit

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83

Metal Base
67.8

60.5
(40.9)
12 B 12 B 12 B 12 B 12 B

Plug-in
4.6

4.6
1.7
)
(4.9)
C6: 3.6
N7: 7.4
12.1

4 x M4 Mounting hole
(Fitting for the type with P/E ports on the U and/or D sides)
(

34.5 L2 1.5

Manifold Exploded View


(5.3) (L4)

Type 50, 51, 52


(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
(Station 1)---(Station n) Applicable tube O.D.: ø2
M12 : ø3.2, ø1/8"

Connector Connecting Base


8-pin socket : ø4, ø5/32"
: ø6, ø1/4"
0
1 P 1 P
63.1
10.6
13.6

56.6

1
60
43.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
22.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail

M12
(7.5)

mounting)

17.5

Plug-in
(Pitch)
(11.8)

8-pin plug
46.3 15.5 P = 10.5 (17.8)

Manifold Exploded View


Type 10, 11, 12


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10SA2-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.5 114 124.5 135 145.5 156 166.5 177 187.5 198 208.5 219 229.5 240 250.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5

154
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX500 (64 Points)

U C4, N3
SS5Y5-10SA2- Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override
1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
SI Unit 2(B) port side : Yellow

DIN rail

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
79.9

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B

10.9
8.7

4.7
(5.9)
(8.3)

4 x M5 Mounting hole

34 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø10, ø3/8" (Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
M12
8-pin socket
0
14.1

1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6

1
60
43.2
33.4

3/5 E 3/5 E
29.1
22.2

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


mounting)
(7.5)

17.5
(11.8)

M12 (Pitch)
48 18 P = 16 (20.5)
8-pin plug


: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10SA2-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.5 136.5 152.5 168.5 184.5 200.5 216.5 232.5 248.5 264.5 280.5 296.5 312.5 328.5 344.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 18 16 14.5

155
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX500 (64 Points)

C6, N7
U
SS5Y7-10SA2- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side
(L5) L1 Manual override
1

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
SI Unit (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
128.8
115
79.9

(5.5)

96.7
(77.1)

Plug-in
12 B 12 B 12 B 12 B 12 B

5.5
24.1

8.8
3.9
(6)
(9.3)

(17.9)

Manifold Exploded View


(A, B port: ø12) 4 x M5 Mounting hole

Type 50, 51, 52


34.2 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting

Connector Connecting Base


[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø6, ø1/4"
[1(P), 3/5(E) port] (Station 1) (Station n) : ø8, ø5/16"
Applicable tube O.D.: ø12, ø1/2" : ø10, ø3/8"
M12 : ø12
8-pin socket
2

0
82.7

1 P 1 P
2 B2 B2 B2 B2 B
56.6

1
60
43.2

11.1

3/5 E 3/5 E
35.2

8.7

Plug-in
31.6

4 A4 A4 A4 A4 A
22.2
14.2

Manifold Exploded View


(For DIN rail

Type 10, 11, 12


(10)

17.5 (21.7)
(14.3)

(Pitch)
mounting)

M12
8-pin plug 53 20.5 P = 19


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10SA2-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.7 153.7 172.7 191.7 210.7 229.7 248.7 267.7 286.7 305.7 324.7 343.7 362.7 381.7 400.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5

156
Plug-in Connector Connecting Base
EX500 Gateway Decentralized System 2 (128 Points)

Series SY3000/5000/7000
Type 12
Top Ported

RoHS
How to Order Manifold

SS5Y 3 12S A3N 05 U


Refer to pages 210 to 212
for dimensions of Type / 4 ) 0 1 6 2
12/Top ported type.

/ Series ) Valve stations 0 P, E port entry


3 SY3000 Stations Note U
1 U side (2 to 10 stations)
5 SY5000 02 2 stations D
1 D side (2 to 10 stations)

7 SY7000 Double wiring


1 B Both sides (2 to 24 stations)

: For mixed mounting, refer to page 213 and 16 16 stations


1: For type “S”, supply/exhaust block
later. 02 2 stations assembly with built-in silencer, choose “U”
Specified layout
2

or “D” for P, E port entry.


(Available up to 32 solenoids)
24 24 stations
4 SI Unit (Number of outputs, Output polarity,
1: Double wiring: 2-position single, double,
Max. number of valve stations) 3-position and 4-position valves can be used on
1 SUP/EXH block assembly
0 Without SI Unit all manifold stations. Use of a 2-position single Nil Internal pilot
32 outputs
1
4, 1 to 16 stations (24 solenoid will result in an unused control signal. If S
1 Internal pilot, Built-in silencer
2
A3N stations
3), Negative common
2 this is not desired, order with a specified layout. R External pilot

1: 16 outputs can be set by switching the


2: Specified layout: Indicate the wiring
1: For type “S”, supply/exhaust block
built-in setting switch. specifications on the manifold specification assembly with built-in silencer, choose “U”

2: Ensure a match with the common sheet. (Note that 2-position double, 3-position or “D” for P, E port entry. 3/5(E) port is
specification of the valve. and 4-position valves cannot be used where plugged. The silencer exhaust port is

3: ( ): Maximum number of stations for single wiring has been specified.) located on the opposite side of P, E port
mixed single and double wiring.
: When the product without the SI Unit (S0) is entry. (Example: When the P, E port entry is

4: When using the SI Unit with 32 outputs, selected, note the maximum number of D side, the silencer exhaust port is U side.)
use the GW Unit compatible with the solenoids of the SI Unit that will be mounted.
2: When the built-in silencer type is used,
EX500 Gateway Decentralized System 2 If the layout is specified, indicate it on the keep the exhaust port from coming in direct
(128 points). manifold specification sheet. contact with water or other liquids.

: This also includes the number of blanking
plate assembly.

How to Order Manifold Assembly 6 P, E port size (One-touch fittings)


SY3000 SY5000 SY7000
Example 2-position double Nil ø8 ø10 ø12
N
1 ø5/16" ø3/8" ø1/2"

1: For “N”, sizes are in inches.

2 Mounting
Nil Direct mounting
D With DIN bracket, DIN rail with standard length
D0 With DIN bracket, without DIN rail
D3
1 With DIN bracket, DIN rail for 3 stations
de


si
U

D24
1 With DIN bracket, DIN rail for 24 stations
ns
tio
ta
S


1: Specify a longer rail than the length of valve stations.
3
2


: If the DIN rail must be mounted without an SI Unit, select “D0”.
1
de

Then, refer to L3 of the dimensions for the DIN rail length and
si
D

order separately. Refer to page 249 for the DIN rail part number.
Manifold base
: Refer to page 271 for the fixation of DIN rail mounting type
manifold.
SS5Y3-12SA3N-05D ········1 set (Manifold base part number)

SY3230-5U1-C6 ·············5 sets (2-position double part number)

: A separate GW Unit and communication cable are required.
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc. For details about the EX500 Gateway-type Serial Transmission
System, refer to the WEB catalog or the Best Pneumatics No.
sThe valve arrangement is numbered as the 1st station from the D side. 1 and the Operation Manual. For details about part numbers of
sUnder the manifold base part number, state the valves to be mounted in SI Units to be mounted, refer to page 235 in this catalog.
order from the 1st station as shown in the figure above. If the arrangement Please download the Operation Manual via SMC website,
becomes complicated, specify on the manifold specification sheet. http://www.smcworld.com

157
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Port size SY3000 SY5000 SY7000
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 ) — —

1: Select the metal seal type for high pressure 01 1/8 — ) —
type. 02 1/4 — — )
4 Type of actuation

Metal Base
One-touch fitting (Metric)
1
2-position
Single 2 Coil type A, B port SY3000 SY5000 SY7000
2 Double Nil Standard C2 ø2 ) — —
3 Closed center C3 ø3.2 ) — —
With power saving circuit
4 3-position Exhaust center T (Continuous duty type)
1
2 C4 ø4 ) ) —

Plug-in
5 Pressure center C6 ø6 ) ) )

1: Be sure to select the power saving circuit
A
1 N.C./N.C. C8 ø8 — ) )
4-position dual type when the valve is continuously energized
B
1 N.O./N.O. for long periods of time. C10 ø10 — — )
3-port valve
C
1 N.C./N.O.
2: Be careful of the energizing time when the C12 ø12 — — )

1: Select the rubber seal type for the 4-position power saving circuit is selected. For details, One-touch fitting (Inch)

Manifold Exploded View


dual 3-port valve. refer to page 268. A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


N1 ø1/8" ) — —
* Rated voltage N3 ø5/32" ) ) —
) Seal type 5 24 VDC
N7 ø1/4" ) ) )
0 Rubber seal
N9 ø5/16" — ) )
1 Metal seal N11 ø3/8" — — )
- Light/surge voltage suppressor
and common specification

Connector Connecting Base


0 Pilot type With light
Surge voltage Common  A, B port thread type
suppressor specification
Nil Internal pilot Nil Rc
R — F G
R External pilot Non-polar
U ) N NPT
)
NS — Negative T NPTF
NZ ) common

: Select “Nil” for M5.
1 Back pressure check valve (Built-in valve type)
: Select “NZ” for with the power saving circuit.
Nil None

Plug-in
H
1 Built-in
 Type of mounting screw

1: Select the rubber seal type when the back


 Manual override
Nil D Nil Round head combination screw
pressure check valve is built-in. Manifold
Non-locking Push-turn B Hexagon socket head cap screw
installed type is available if the back

Manifold Exploded View


pressure check valve is required for a valve push locking Round head combination screw
K (Falling-out-prevention type
1) Type 10, 11, 12
with metal seal. For ordering example, refer (slotted)
to page 256. However, it is not Hexagon socket head cap screw
H (Falling-out-prevention type
1)
recommended to use the built-in valve type
and the manifold installed type at the same
1: For “K” and “H”, the valve body cover has a
time because it will reduce the flow. drop prevention construction to stop the

: Select “Nil” for 3-position type and the E F mounting screws from falling out when the
SY7000. Push-turn Slide locking valve is removed for maintenance etc.
locking (manual)
: When ordering a valve individually, the
Plug Assembly Part No.

(manual) base gasket is not included.


One-touch Fittings/

Since the base gasket is attached to the


manifold, please order the base gasket
separately if it is needed for maintenance
service.

: Refer to page 31 for with the safety slide locking Refer to page 244 for part numbers of the
manual override. base gasket and mounting screw.

: Select “Nil” or “K” for the optional individual
Manifold Options

SUP/EXH spacer assembly or interface


regulator.

Protective class
class  (Mark: )

158
Plug-in Connector Connecting Base
EX500 Gateway Decentralized System (64 Points)
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12S A2 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top
ported type.
/ 4 ) 0 1 6 2
/ Series 0 P, E port entry ) Valve stations
3 SY3000 U
1 U side (2 to 10 stations) Symbol Stations Note
5 SY5000 D
1 D side (2 to 10 stations) 02 2 stations
Double wiring
1

···
7 B

···
SY7000 Both sides (2 to 16 stations)

: For mixed mounting, refer to page 213 and


1: 1For type “S”, supply/exhaust block 08 8 stations
later. assembly with built-in silencer, choose U or 02 2 stations
D for P port entry. Specified layout
2

···

···
(Available up to 16 solenoids)
16 16 stations
4 SI Unit (Number of outputs, Output polarity,
1: Double wiring: 2-position single, double,
Max. number of valve stations) 1 SUP/EXH block assembly 3-position and 4-position valves can be
0 Without SI Unit Nil Internal pilot used on all manifold stations.
16 outputs, S Internal pilot/Built-in silencer Use of a 2-position single solenoid will
A2 Positive common
1, R External pilot result in an unused control signal. If this is
1 to 8 stations (16 stations)
2 not desired, order with a specified layout.

: For built-in silencer type, P and E ports are
2: Specified layout: Indicate the wiring
16 outputs, available on U and D sides. 3/5(E) port is specifications on the manifold specification
A2N Negative common
1, plugged. The silencer exhaust port is located sheet. (Note that 2-position double,
1 to 8 stations (16 stations)
2 on the opposite side of P, E port entry. 3-position and 4-position valves cannot be
(Example: When the P, E port entry is D used where single wiring has been

1: Ensure a match with the common side, the silencer exhaust port is U side.)
specification of the valve to be used. specified.)

: When the built-in silencer type is used, keep
: When the product without the SI Unit (S0) is

2: ( ): Maximum number of stations for mixed the exhaust port from coming in direct
single and double wiring. selected, note the maximum number of
contact with water or other liquids. solenoids of the SI Unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly
: This also includes the number of blanking
plate assembly.

Example (SS5Y3-12SA2-:)
2-position double (24 VDC)
6 P, E port size (One-touch fittings)
SY3230-5U1-C6 (1 set) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC)
Nil ø8 ø10 ø12
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC) N ø5/16" ø3/8" ø1/2"
SY3330-5U1-C6 (1 set)

: For N, sizes are in inches.

2 Mounting
Nil Direct mounting
ide D With DIN bracket, DIN rail with standard length
Us D0 With DIN bracket, without DIN rail
s
n

D3
1
tio

With DIN bracket, DIN rail for 3 stations


ta
S

···

···

3
2 D16
1 With DIN bracket, DIN rail for 16 stations
1
ide
Manifold base Ds
1: Specify a longer rail than the length of valve stations.
(5 stations)
: If the DIN rail must be mounted without an SI Unit, select
SS5Y3-12SA2-05D “D0”. Then, refer to L3 of the dimensions for the DIN rail
length and order separately. Refer to page 249 for the DIN
rail part number.
SS5Y3-12SA2-05D ··· 1 set (Type 12 5-station manifold base part no.)

: Refer to page 271 for the fixation of DIN rail mounting type

SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
manifold.

SY3230-5U1-C6 ········ 1 set (2-position double part no.)

SY3330-5U1-C6 ········ 1 set (3-position closed center part no.)
: A separate GW Unit and communication cable are required.
The asterisk denotes the symbol for assembly. For details about the EX500 Gateway-type Serial
Prefix it to the part numbers of the valve etc. Transmission System, refer to the WEB catalog or the
s The valve arrangement is numbered as the 1st station from the D side. Best Pneumatics No. 1 and the Operation Manual. For
sUnder the manifold part number, state the valves to be mounted in order details about part numbers of SI Units to be mounted, refer
from the 1st station as shown in the figure above. If the arrangement to page 236 in this catalog. Please download the Operation
becomes complicated, specify on a manifold specification sheet. Manual via SMC website, http://www.smcworld.com

159
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
4 Type of actuation

Metal Base
One-touch fitting (Metric)
2 Coil type Symbol A, B port SY3000 SY5000 SY7000
1 Single
Nil Standard
2-position C2 ø2 ) — —
2 Double
T With power saving circuit (Continuous duty type)
3 Closed center C3 ø3.2 ) — —

: Be sure to select the power saving circuit
4 3-position Exhaust center C4 ø4 ) ) —

Plug-in
type when the valve is continuously
5 Pressure center energized for long periods of time. C6 ø6 ) ) )
A
1 N.C./N.C.
: Be careful of the energizing time when the C8 ø8 — ) )
4-position power saving circuit is selected. Refer to C10 ø10 — — )
B
1 dual 3-port N.O./N.O.
C
1 N.C./N.O. page 268 for details. C12 ø12 — — )

1: Only rubber seal type is available for the One-touch fitting (Inch)
* Rated voltage

Manifold Exploded View


4-position dual 3-port valve. Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


5 24 VDC N1 ø1/8" ) — —
N3 ø5/32" ) ) —
) Seal type - Light/surge voltage suppressor N7 ø1/4" ) ) )
0 N9 ø5/16" — ) )
Rubber seal and common specification
1 Metal seal
N11 ø3/8" — — )
Surge voltage Common
Symbol With light
suppressor specification
R —

Connector Connecting Base


Non-polar
0 Pilot type U )  Thread type
S — Positive Nil Rc
Nil Internal pilot )
Z ) common F G
R External pilot —
NS Negative N NPT
NZ ) common T NPTF

: Select “Z” or “NZ” for with the power saving
: Only Nil is available for M5.
1 Back pressure check valve circuit. Select a valve from R, U, S or Z when
the SI Unit specification is A2 (positive
(Built-in valve type) common). Select a valve from R, U, NS or

Plug-in
Nil
H
None
Built-in
NZ when the SI Unit specification is A2N
(negative common).
 Type of mounting screw
Nil Round head combination screw

: Only rubber seal type. Manifold installed type Hexagon socket head cap screw
B

Manifold Exploded View


is available if the back pressure check valve
K Round head combination screw (Falling-out-prevention type)
is required for a valve with metal seal. Refer
to page 256 for Ordering Example. However,
 Manual override H Hexagon socket head cap screw (Falling-out-prevention type)
Type 10, 11, 12
it is not recommended to use the built-in Nil: D:
: For “K” and “H”, the valve body cover has a
valve type and the manifold installed type at Non-locking Push-turn drop prevention construction to stop the
the same time because it will reduce the flow. push type locking slotted mounting screws from falling out when the

: The built-in valve type back pressure check type valve is removed for maintenance etc.
valve is not available for the 3-position type
: When ordering a valve individually, the
and the SY7000. base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
Plug Assembly Part No.

separately if it is needed for maintenance


One-touch Fittings/

E: F: service.
Push-turn Slide locking Refer to page 244 for part numbers of the
locking lever type base gasket and mounting screw.
type
: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
160
Plug-in Connector Connecting Base
Type 10
Side Ported EX600

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 3 10 S6 Q 2 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type. / 4 ) 0 1 6 2 * -
/ Series 1 I/O Unit stations - Mounting and Option
3 SY3000 Nil None Option
Symbol Mounting
5 SY5000 1 1 station Name plate Station number
Nil
···

···
7 SY7000 — —
Direct
9 9 stations AA mounting
) )

: Without SI Unit, the symbol is nil. BA ) —

: SI Unit is not included in I/O Unit stations.
4 Type
: When I/O Unit is selected, it is shipped
D:
A:
DIN rail

)

)
10 Side ported separately, and assembled by users. Refer to mounting
B: ) —
11 Bottom ported
1 the attached operation manual for mounting.

: Enter the number of stations inside : when it

1: The SY5000 manifold base is used for the


is larger than the number of valve stations.
bottom ported of the SY3000. When
(Refer to “DIN Rail Option” below.)
ordering, refer to “Plug-in Mixed Mounting

: Only direct mounting is available for Type 11
Type Manifold” (from page 213).
6 Valve stations (Bottom ported).

: Refer to page 271 for the fixation of DIN rail
Symbol Stations Note mounting type manifold.
) SI Unit 02 2 stations DIN Rail Option
0 Without SI Unit Double wiring
1
···

···

Nil Direct mounting


Q DeviceNet™ 16 16 stations
0 Without DIN rail (with bracket)
N PROFIBUS DP 02 2 stations
Specified layout
2 3 For 3 stations
V CC-Link Specify a longer rail than the
···

···

···

···

(Available up to 32 solenoids)
ZE EtherNet/IP™ (1 port) 24 24 stations total length of specified stations.
24 For 24 stations
EA EtherNet/IP™ (2 ports)
1: Double wiring: 2-position single, double,
D EtherCAT ®
: If the DIN rail must be mounted without an SI
3-position and 4-position valves can be
Unit, select D0. Then, refer to L3 of the
F PROFINET used on all manifold stations.
dimensions for the DIN rail length and order

: I/O Unit cannot be mounted without SI Unit. Use of a 2-position single solenoid will
separately. (Refer to page 249 for the DIN

: Valve plate which connects manifold and SI result in an unused control signal. If this is
rail part number.)
Unit is not mounted to a valve without SI not desired, order with a specified layout.
Unit. Refer to the EX600 catalog
2: Specified layout: Indicate the wiring
(CAT.E02-24) for mounting. specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be
used where single wiring has been
specified.)

: This also includes the number of blanking
0 SI Unit output polarity, end plate type plate assembly.
Power supply Power supply
SI Unit output polarity with M12 with 7/8 inch
connector connector
Without SI Unit Nil 2 P, E port entry, SUP/EXH block assembly
SI Unit positive common 2 3 Internal Internal pilot, External
P, E port entry
SI Unit negative common 4 5 pilot Built-in silencer pilot

: Ensure a match with the common U side (2 to 10 stations) U C G


specification of the valve to be used. D side (2 to 10 stations) D E H

: Without SI Unit, the symbol is nil. Both sides (2 to 24 stations) B F J



: 3/5(E) port is plugged for the built-in silencer type.

: When the built-in silencer type is used, keep the exhaust port from
coming in direct contact with water or other liquids.

Refer to the page on the right for *.

For details about the EX600 Integrated-type (For Input/Output) Serial


Transmission System, refer to the WEB catalog or the Best Pneumatics No.
1 and the Operation Manual. For details about part numbers of SI Units to
be mounted, refer to pages 237 and 238 in this catalog. (IP40 specifications
may be required according to the I/O Unit to be selected.) Please download
the Operation Manual via SMC website, http://www.smcworld.com

161
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
* A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
How to Order Manifold Assembly

Manifold Exploded View


Type 10, 11, 12
Example (SS5Y3-10S6:-:) SS5Y3-10S6Q42-05B-C6 ··· 1 set (Type 10 5-station manifold base part no.)

SY3100-5U1 ······················· 3 sets (2-position single part no.)

SY3200-5U1 ······················· 2 sets (2-position double part no.)
Digital Input Unit Digital Output Unit 2-position single
EX600-DXPD ····················· 1 set I/O Unit part number (Station 1)
EX600-DXPD EX600-DYPB SY3100-5U1 (3 sets)
EX600-DYPB ····················· 1 set I/O Unit part number (Station 2)
End plate
1 SI Unit
1 2-position double The asterisk denotes the symbol for assembly.
EX600-ED2 EX600-SDN1 SY3200-5U1 (2 sets) Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
Plug Assembly Part No.

0 1
One-touch Fittings/

s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTED THENTHE


2 3
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A I/O Units in order from the 1st station as shown in the figure above.
D side
PWR
OUT U side If the arrangement becomes complicated, specify on a manifold
0 1
4 5 specification sheet.
2 3 12 B 12 B 12 B 12 B 12 B
PCI
BUS BUS
IN OUT

1: Do not enter the SI Unit part number and the end plate part number
8 7
together.

: When mixing top ported configurations, select from page 172.
Manifold Options

1 2 3 4 5 Valve stations In this case, use caution as there is also output on the A and B port on base
1 2 I/O Unit stations
side.
Specify on a manifold specification sheet if plugs are required on the A and
B port on base side.

Protective class
class  (Mark: )
162
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O.
page 268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC

) Seal type  Type of mounting screw


Nil Round head combination screw
0 Rubber seal
1 Metal seal
- Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification K Round head combination screw (Falling-out-prevention type)
Surge voltage Common H Hexagon socket head cap screw (Falling-out-prevention type)
Symbol With light
suppressor specification
: For “K” and “H”, the valve body cover has a
0 Pilot type R —
Non-polar
drop prevention construction to stop the
mounting screws from falling out when the
Nil Internal pilot U )
valve is removed for maintenance etc.
R External pilot S — Positive
: When ordering a valve individually, the
)
Z ) common base gasket is not included.
NS — Negative Since the base gasket is attached to the
NZ ) common manifold, please order the base gasket
1 Back pressure check valve
: Select a valve from R, U, S or Z when the SI
separately if it is needed for maintenance
(Built-in valve type) service.
Unit polarity is positive common. Select a
Nil None Refer to page 244 for part numbers of the
valve from R, U, NS or NZ when the SI Unit
base gasket and mounting screw.
H Built-in output polarity is negative common.

: “B” and “H” cannot be selected for the

: Only rubber seal type. Manifold installed type


: Only “Z” and “NZ” types are available for with
individual SUP/EXH spacer assembly,
is available if the back pressure check valve the power saving circuit.
interface regulator or double check spacer
is required for a valve with metal seal. Refer assembly with residual pressure release
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
163
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX600 (M12 Connector)

U C2
SS5Y3-10S6: 42 :- Stations D - C3, N1
C4, N3 (D) B C6, N7

Sub-plate
D side U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) Manual override
1
(L5) L1

Plug-in
DIN rail holding screw 5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 47 8 DIN rail holding screw 1.5 4(A) port side
Communication connector
(For DIN rail mounting) : Blue (For rubber seal)
Power connector 2 x M4 Mounting hole : Gray (For metal seal)
85.1 (Light/surge 2(B) port side : Yellow
Marker groove
voltage suppressor)

0 1

(5.5)

Metal Base
B A B A B A B A B A

(35)
2 3

92.6
14 A 14 A 14 A 14 A 14 A

83
106

PWR
90

OUT

60.5
0 1

(40.9)
4 5
2 3

Plug-in
4.6
12 B 12 B 12 B 12 B 12 B
BUS PCI BUS (8)
IN OUT

8 7

1.7
8

4.6
)
(4.9)

C6: 3.6
N7: 7.4
86.6 FE
terminal 5.4 4 x M4 Mounting hole

Manifold Exploded View


(
End plate

Type 50, 51, 52


(Fitting for the type with P/E
Digital Input Unit ports on the U and/or D sides)
Valve plate
Input connector
SI Unit
Output connector One-touch fitting
Digital Output Unit Connector for handheld terminal [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
(Station 1)---(Station n) : ø4, ø5/32"
11.5

Connector Connecting Base


: ø6, ø1/4"
8

1 P 1 P

63.1
56.6

3/5 E 3/5 E
13.2

2 B2 B2 B2 B2 B

40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6

Plug-in
(For DIN rail

(7.5)
mounting)

One-touch fitting
(11.8)

(Pitch)
[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)
Applicable tube O.D.: ø8, ø5/16"

Manifold Exploded View


Type 10, 11, 12
L1 = 10.5 x n1 + 135.5 + 47 x n2
1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 10.5 x n1 + 42
: These figures show the “SS5Y3-10S6Q22-05D-C6”.
L4 = L3 – 10.5
: Refer to page 210 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O Unit stations
Plug Assembly Part No.

L3: DIN Rail Overall Length


One-touch Fittings/

Valve
stations
I/O (n1)
Unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
Manifold Options

1 235.5 248 248 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5
2 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 485.5 485.5 498 510.5
3 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5
4 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 473 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5
5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648
6 473 473 485.5 498 510.5 523 535.5 535.5 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698
7 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748
8 560.5 573 585.5 598 598 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798
9 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748 760.5 760.5 773 785.5 798 810.5 823 835.5 835.5
164
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C2
SS5Y3-10S6: 53 :- Stations D - C3, N1
C4, N3 (D) B C6, N7

D side U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override
1

DIN rail holding screw


5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
Communication connector 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN rail mounting) (For DIN rail mounting) : Blue (For rubber seal)
2 x M4 Mounting hole
(Light/surge : Gray (For metal seal)
Marker groove 2(B) port side : Yellow
voltage suppressor)

0 1

(5.5)
B A B A B A B A B A

(35)
2 3

92.6
14 A 14 A 14 A 14 A 14 A

83
106
90

60.5
0 1

(40.9)
4 5
PWR

2 3

4.6
12 B 12 B 12 B 12 B 12 B
BUS PCI BUS (8)
53

IN OUT

8 7

4.6
1.7
8

)
(4.9)

C6: 3.6
N7: 7.4
36.7 FE
terminal 5.4 4 x M4 Mounting hole

(
Power connector End plate
(Fitting for the type with P/E
Digital Input Unit ports on the U and/or D sides)
Valve plate
Input connector One-touch fitting
Output connector SI Unit [4(A), 2(B) port]
Applicable tube O.D.: ø2
Digital Output Unit Connector for handheld terminal : ø3.2, ø1/8"
: ø4, ø5/32"
11.5

(Station 1)---(Station n)
: ø6, ø1/4"
8

1 P 1 P

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
13.2

40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6
(For DIN rail

(7.5)
mounting)

One-touch fitting (Pitch)


(11.8)

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: ø8, ø5/16"


1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L1 = 10.5 x n1 + 152 + 47 x n2
: These figures show the “SS5Y3-10S6Q32-05D-C6”.
L2 = 10.5 x n1 + 42
: Refer to page 210 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O Unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
Unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5
1 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
2 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 523 523
3 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573
4 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 585.5 585.5 598 610.5 623
5 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673
6 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 648 648 660.5 673 685.5 698 710.5 710.5
7 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5
8 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 710.5 710.5 723 735.5 748 760.5 773 773 785.5 798 810.5
9 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798 798 810.5 823 835.5 848 860.5
165
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY5000 Connector Connecting Base EX600 (M12 Connector)

U C4, N3
SS5Y5-10S6: 42 :- Stations D - C6, N7 (D)
B C8, N9

Sub-plate
D side U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(L5) L1 Manual override
1

Plug-in
(For DIN rail mounting)
Power connector
5.5
Communication connector
L6 L2
(
Push-turn locking slotted type:
Press, then rotate it. )
47 8 DIN rail holding screw 1.5 4(A) port side
DIN rail
2 x M4 Mounting hole (For DIN rail mounting) : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
85.1 Marker groove 2(B) port side : Yellow

0 1

(5.5)

Metal Base
BA BA BA BA BA

(35)
2 3 14 A 14 A 14 A 14 A 14 A

97.5
113.4
90

PWR
OUT
0 1
4 5

81.2

Plug-in
2 3
(8)

(61.7)
PCI
BUS BUS
IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

10.9
15.4

4.7
(5.9)

Manifold Exploded View


(8.3)

86.6 FE terminal 5.4

Type 50, 51, 52


4 x M5 Mounting hole
End plate
(Fitting for the type with P/E
Digital Input Unit
ports on the U and/or D sides)
Valve plate
Input connector
One-touch fitting
SI Unit
Output connector [4(A), 2(B) port]
Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"
Digital Output Unit : ø6, ø1/4"
(Station 1)----------(Station n)

Connector Connecting Base


: ø8, ø5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
12.4
14.1
8.7

Plug-in
(7.5)

One-touch fitting
(For DIN rail
mounting)

[1(P), 3/5(E) port] (Pitch)


(11.8)

Applicable tube O.D.: ø10, ø3/8" 20 18 P = 16 (20.5)

Manifold Exploded View


Type 10, 11, 12
L1 = 16 x n1 + 141.5 + 47 x n2
1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 16 x n1 + 48
: These figures show the “SS5Y5-10S6Q22-05D-C8”.
L4 = L3 – 10.5
: Refer to page 211 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O Unit stations
Plug Assembly Part No.

L3: DIN Rail Overall Length


One-touch Fittings/

Valve
stations
I/O (n1)
Unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
Manifold Options

1 248 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598
2 298 310.5 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648
3 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698
4 385.5 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748
5 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5
6 485.5 498 523 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5
7 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5
8 573 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5
9 623 648 660.5 673 685.5 710.5 723 735.5 748 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973
166
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C4, N3
SS5Y5-10S6: 53 :- Stations D - C6, N7 (D)
B C8, N9
D side U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override
1

5.5 L6 L2 (Push-turn locking slotted type:


Press, then rotate it. )
DIN rail holding screw 16.5 2 x M4 Mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN rail mounting) Communication connector (For DIN rail mounting) : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
DIN rail Marker groove 2(B) port side: Yellow

0 1

(5.5)
BA BA BA BA BA

(35)
2 3 14 A 14 A 14 A 14 A 14 A
90

97.5
113.4
0 1
4 5

81.2
PWR

2 3
(8)

(61.7)
PCI
60.4

BUS BUS
IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

10.9
15.4

4.7
(5.9)
36.7 (8.3)
Power connector FE terminal 5.4 4 x M5 Mounting hole

End plate (Fitting for the type with P/E


ports on the U and/or D sides)
Digital Input Unit
Valve plate
Input connector One-touch fitting
SI Unit
[4(A), 2(B) port]
Output connector Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"
Digital Output Unit (Station 1)----------(Station n) : ø6, ø1/4"
: ø8, ø5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
14.1
12.4
8.7
(For DIN rail

(7.5)
mounting)

One-touch fitting (Pitch)


(11.8)

[1(P), 3/5(E) port] 20 18 P = 16 (20.5)


Applicable tube O.D.: ø10, ø3/8"


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L1 = 16 x n1 + 158 + 47 x n2

: These figures show the “SS5Y5-10S6Q32-05D-C8”.
L2 = 16 x n1 + 48

: Refer to page 211 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O Unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
Unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573
1 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573 585.5 598 623
2 310.5 335.5 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5
3 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5
4 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5 723 748 760.5
5 460.5 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5 810.5
6 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848
7 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848 873 885.5 898
8 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5 948
9 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973 —
167
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX600 (M12 Connector)

U C6, N7
SS5Y7-10S6: 42 :- Stations D - C8, N9
C10, N11 (D) B C12
D side U side

Sub-plate
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Manual override
1
DIN rail holding screw (L5) L1
( )

Plug-in
Push-turn locking slotted
(For DIN rail mounting) 5.5 L6 L2 type: Press, then rotate it.
Power connector 2 x M4 Mounting hole 47 8 1.5 4(A) port side
DIN rail holding screw
(DIN rail) Communication connector (For DIN rail mounting) : Blue (For rubber seal)
: Gray (For metal seal)
Marker groove Valve plate Light/surge voltage suppressor 2(B) port side: Yellow
85.1

0 1

(5.5)

Metal Base
B A B A B A B A B A

(35)
2 3
14 A 14 A 14 A 14 A 14 A
90

PWR

128.8
OUT

115
0 1
4 5
2 3

96.7
PCI
FE BUS BUS (8)

Plug-in
IN OUT

(77.1)
terminal
8 7
12 B 12 B 12 B 12 B 12 B

5.5
30.8
22.8

5.4

8.8

Manifold Exploded View


3.9
(6)
SI Unit
(9.3)

86.6

Type 50, 51, 52


(17.9)
(A, B port: ø12) 4 x M5 Mounting hole
End plate Connector for (Fitting for the type with P/E
handheld terminal ports on the U and/or D sides)
Digital Input Unit Digital Output Unit
One-touch fitting
Input connector Output connector [4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12

Connector Connecting Base


11.5

2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A
11.1
14.2
8.7

Plug-in
(For DIN rail

(Pitch)
(10)
mounting)
(14.3)

One-touch fitting 25 20.5 P = 19 (21.7)


[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"

Manifold Exploded View


Type 10, 11, 12
L1 = 19 x n1 + 149.7 + 47 x n2
1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 19 x n1 + 56
: These figures show the “SS5Y7-10S6Q22-05D-C10”.
L3 = DIN rail dimension
: Refer to page 212 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O Unit stations
Plug Assembly Part No.
One-touch Fittings/

L3: DIN Rail Overall Length


Valve
I/O stations
Unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
Manifold Options

1 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5
2 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723
3 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5 760.5 773
4 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823
5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 648 660.5 685.5 698 723 735.5 760.5 773 798 810.5 835.5 848 873
6 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 923
7 548 560.5 585.5 598 623 635.5 660.5 673 698 723 735.5 760.5 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5
8 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 — —
9 635.5 660.5 673 698 710.5 735.5 748 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5 985.5 — — — —
168
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C6, N7
SS5Y7-10S6: 53 :- Stations D - C8, N9
C10, N11 (D) B C12
D side U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override
1

DIN rail holding screw


5.5
16.5 2 x M4 Mounting hole
L6
47 8 DIN rail holding screw
L2
1.5
( Push-turn locking slotted
type: Press, then rotate it. )
(For DIN rail mounting) 4(A) port side
Communication connector (For DIN rail mounting) : Blue (For rubber seal)
Power connector (DIN rail) Light/surge voltage suppressor : Gray (For metal seal)
Marker groove
2(B) port side: Yellow

0 1

(5.5)
B A B A B A B A B A

(35)
2 3
14 A 14 A 14 A 14 A 14 A
90

128.8
115
0 1
4 5
PWR

2 3

96.7
PCI
FE BUS
IN
BUS
OUT (8)

(77.1)
terminal
75.8

8 7

5.5
12 B 12 B 12 B 12 B 12 B
31
22.8

5.4

8.8
3.9
End plate
(6)
(9.3)
36.7

(17.9)
Digital Input Unit (A, B port: ø12) 4 x M5 Mounting hole

Input connector Valve plate (Fitting for the type with P/E
ports on the U and/or D sides)
Output connector SI Unit

Digital Output Unit Connector for One-touch fitting


handheld terminal [4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
: ø10, ø3/8"
[1(P), 3/5(E) port] : ø12
Applicable tube O.D.: ø12, ø1/2"
11.5

2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

8.7
3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A
11.1
14.2
(For DIN rail

(Pitch)
(10)
mounting)
(14.3)

25 20.5 P = 19 (21.7)

L1 = 19 x n1 + 166.2 + 47 x n2
1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 19 x n1 + 56
: These figures show the “SS5Y7-10S6Q32-05D-C10”.
L4 = L3 – 10.5
: Refer to page 212 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O Unit stations

L3: DIN Rail Overall Length


Valve
I/O stations
Unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 235.5 248 273 285.5 310.5 323 348 360.5 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648
1 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 685.5 698
2 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748
3 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 760.5 773 798
4 423 435.5 460.5 473 498 510.5 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5
5 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 835.5 848 873 885.5
6 510.5 535.5 548 573 585.5 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5
7 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 910.5 923 948 960.5 985.5
8 610.5 623 648 660.5 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 985.5 — —
9 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 898 923 935.5 960.5 985.5 — — — — —
169
170
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
EX600
Type 12
Top Ported
Series SY3000/5000/7000 RoHS
How to Order Manifold

SS5Y 3 12S6 Q 2 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top
ported type. / 4 ) 0 1 6 2 *
/ Series ) SI Unit output polarity, end plate type 1 Valve stations
3 SY3000 Power supply Power supply Symbol Stations Note
SI Unit output polarity with M12 with 7/8 inch
5 SY5000 connector connector 02 2 stations
Double wiring
1

···
7 Nil

···
SY7000 Without SI Unit
SI Unit positive common 2 3 16 16 stations
SI Unit negative common 4 5 02 2 stations
4 SI Unit Specified layout
2

···

···

: Without SI Unit, the symbol is nil. (Available up to 32 solenoids)
0 Without SI Unit

: Ensure a match with the common 24 24 stations
Q DeviceNet™ specification of the valve to be used.
1: Double wiring: 2-position single, double,
N PROFIBUS DP
3-position and 4-position valves can be used
V CC-Link 0 I/O Unit stations on all manifold stations.
ZE EtherNet/IP™ (1 port) Nil None Use of a 2-position single solenoid will result
EA EtherNet/IP™ (2 ports) 1 1 station in an unused control signal. If this is not
D EtherCAT ® desired, order with a specified layout.
···

···

F PROFINET
2: Specified layout: Indicate the wiring
9 9 stations
specifications on the manifold specification

: I/O Unit cannot be mounted without SI Unit.


: Without SI Unit, the symbol is nil. sheet. (Note that 2-position double,

: Valve plate which connects manifold and SI


: SI Unit is not included in I/O Unit stations. 3-position and 4-position valves cannot be
Unit is not mounted to a valve without SI Unit.
: When I/O Unit is selected, it is shipped used where single wiring has been
Refer to the EX600 catalog (CAT.E02-24) for separately, and assembled by users. Refer to specified.)
mounting. the attached operation manual for mounting.
: This also includes the number of blanking
plate assembly.

6 P, E port entry, SUP/EXH block assembly


Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
U side (2 to 10 stations) U C
1 G
How to Order Manifold Assembly D side (2 to 10 stations) D E
1 H
Both sides (2 to 24 stations) B — J

1: For SUP/EXH block assembly specifications, built-in silencer types will
Example (SS5Y3-12S6:-:) have P port entry stipulated.

: For built-in silencer type, P and E ports are available on U and D sides.
Digital Input Unit Digital Output Unit 2-position single 3/5(E) port is plugged. The silencer exhaust port is located on the
EX600-DXPD EX600-DYPB SY3130-5U1-C6 (3 sets) opposite side of P, E port entry. (Example: When the P, E port entry is
End plate
1 SI Unit
1 D side, the silencer exhaust port is U side.)
2-position double

: When the built-in silencer type is used, keep the exhaust port from
EX600-ED2 EX600-SDN1 SY3230-5U1-C6 (2 sets)
coming in direct contact with water or other liquids.

2 P, E port size (One-touch fittings)


0 1

PE PE
X X
3/5E B A B A B A B A B A 3/5E
2 3 4A 4A 4A 4A 4A
Symbol SY3000 SY5000 SY7000
PWR
D side OUT
0 1
U side
4 5
2 3 1P
2B 2B 2B 2B 2B
1P
Nil ø8 ø10 ø12
PCI
BUS BUS
IN OUT

8 7
N ø5/16" ø3/8" ø1/2"

: For N, sizes are in inches.
1 2 3 4 5 Valve stations
1 2 I/O Unit stations * Mounting
Nil Direct mounting
SS5Y3-12S6Q42-05B ·········· 1 set (Type 12 5-station manifold base part no.) D DIN rail mounting (With DIN rail)

SY3130-5U1-C6 ················· 3 sets (2-position single part no.) D0 DIN rail mounting (Without DIN rail)

SY3230-5U1-C6 ················ 2 sets (2-position double part no.) D3 For 3 stations

EX600-DXPD ······················ 1 set I/O Unit part number (Station 1) Specify a longer rail
···

···


EX600-DYPB ······················ 1 set I/O Unit part number (Station 2) than the standard length.
D24 For 24 stations
The asterisk denotes the symbol for assembly.
: When it is necessary to mount a DIN rail without an SI Unit, select D0
Prefix it to the part numbers of the valve etc. and order DIN rail length separately, referring to L3 in the dimensions.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE (Refer to page 249 for part numbers of DIN rail.)
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTED THEN
: Refer to page 271 for the fixation of DIN rail mounting type manifold.
the I/O Units in order from the 1st station as shown in the figure above. For details about the EX600 Integrated-type (For Input/Output) Serial
If the arrangement becomes complicated, specify on a manifold specification Transmission System, refer to the WEB catalog or the Best Pneumatics No.
sheet. 1 and the Operation Manual. For details about part numbers of SI Units to

1: Do not enter the SI Unit part number and the end plate part number be mounted, refer to pages 237 and 238 in this catalog. (IP40 specifications
together. may be required according to the I/O Unit to be selected.) Please download
the Operation Manual via SMC website, http://www.smcworld.com

171
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

Metal Base
One-touch fitting (Metric)
4 Type of actuation 2 Coil type
1 Single
Symbol A, B port SY3000 SY5000 SY7000
2-position Nil Standard C2 ø2 ) — —
2 Double
T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
3 Closed center

: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
4 3-position Exhaust center
type when the valve is continuously C6 ø6 ) ) )
5 Pressure center energized for long periods of time. C8 ø8 — ) )
A
1 N.C./N.C.
: Be careful of the energizing time when the
4-position C10 ø10 — — )
B
1 dual 3-port N.O./N.O. power saving circuit is selected. Refer to page
268 for details. C12 ø12 — — )
C
1 N.C./N.O.

1: Only rubber seal type is available for the One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve. * Rated voltage Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


5 24 VDC N1 ø1/8" ) — —
N3 ø5/32" ) ) —
N7 ø1/4" ) ) )
) Seal type - Light/surge voltage suppressor N9 ø5/16" — ) )
0 Rubber seal N11 ø3/8" — — )
1 Metal seal
and common specification
Surge voltage Common
Symbol With light
suppressor specification

Connector Connecting Base


R —
Non-polar  Thread type
0 Pilot type U )
Nil Rc
S — Positive
Nil Internal pilot ) F G
Z ) common
R External pilot N NPT
NS — Negative T NPTF
NZ ) common

: Only Nil is available for M5.

: Select a valve from R, U, S or Z when the SI
1 Back pressure check valve Unit polarity is positive common. Select a
valve from R, U, NS or NZ when the SI Unit

Plug-in
Nil None output polarity is negative common.
H Built-in
: Only “Z” and “NZ” types are available for with  Type of mounting screw

: Only rubber seal type. Manifold installed type the power saving circuit. Nil Round head combination screw

Manifold Exploded View


is available if the back pressure check valve B Hexagon socket head cap screw
is required for a valve with metal seal. Refer K Round head combination screw (Falling-out-prevention type) Type 10, 11, 12
to page 256 for Ordering Example. However,  Manual override H Hexagon socket head cap screw (Falling-out-prevention type)
it is not recommended to use the built-in
Nil: D:
: For “K” and “H”, the valve body cover has a
valve type and the manifold installed type at
Non-locking Push-turn drop prevention construction to stop the
the same time because it will reduce the flow.
push type locking slotted mounting screws from falling out when the

: The built-in valve type back pressure check


type valve is removed for maintenance etc.
valve is not available for the 3-position type
and the SY7000.
: When ordering a valve individually, the
base gasket is not included.
Since the base gasket is attached to the
Plug Assembly Part No.

manifold, please order the base gasket


One-touch Fittings/

separately if it is needed for maintenance


E: F:
service.
Push-turn Slide locking
Refer to page 244 for part numbers of the
locking lever type
base gasket and mounting screw.
type

: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
172
Plug-in Connector Connecting Base
Type 10
Side Ported EX250

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 208 (SY5000) and


SS5Y 3 10 S Q 05 U C6
209 (SY7000) for dimensions of
Type 11/Bottom ported type. / 4 ) 0 1 6 2 * -
/ Series ) SI Unit 1 Input block type
3 SY3000 0 Without SI Unit PNP input NPN input
5 SY5000 Q DeviceNet™ (Negative common) (Positive common) (Negative common)
7 SY7000 N PROFIBUS DP (Negative common) Without input block Nil
V CC-Link (Positive common) M12, 2 inputs A D
4 Type TA 2 power 8 in/8 out, 31 slave modes
supply
AS-Interface systems
M12, 4 inputs B E
10 Side ported TB 4 in/4 out, 31 slave modes M8, 4 inputs C F
(Negative 1 power
11 Bottom ported
1 TC common) supply
8 in/8 out, 31 slave modes
: Without SI Unit, the symbol is nil.

1: The SY5000 manifold base is used for the


TD systems 4 in/4 out, 31 slave modes
bottom ported of the SY3000. When Y CANopen (Negative common) 6 Valve stations
ordering, refer to “Plug-in Mixed Mounting ZE EtherNet/IP™ (Negative common) Symbol Stations Note
Type Manifold” (from page 213).
: Ensure a match with the common 02 2 stations
specification of the valve to be used.

···
Double wiring
1

···
0 Input block stations
: Input block cannot be mounted without SI 16 16 stations
Nil None Unit.

: The supply current from the SI Unit of 02 2 stations
1 1 station Specified layout
2
···

···
AS-Interface applicable 1 power supply (Available up to 32 solenoids)
···

···

system specification to the input block and 24 24 stations


8 8 stations valve is limited.
1: Double wiring: 2-position single, double,

: Without SI Unit, the symbol is nil. The 3-position and 4-position valves can be
maximum number of stations is limited for used on all manifold stations.
the AS-Interface applicable SI Unit. Use of a 2-position single solenoid will
result in an unused control signal. If this is
not desired, order with a specified layout.
How to Order Manifold Assembly
2: Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position
Example (SS5Y3-10S:-:) 3-position closed and 4-position valves cannot be used where
2-position double (24 VDC) center (24 VDC) single wiring has been specified.)
SY3200-5U1 (1 set) SY3300-5U1 (1 set) When determining the number of valve
stations, note that the maximum number of
solenoids for the AS-Interface applicable SI
2-position single (24 VDC) Unit specification is as follows.
SY3100-5U1 (3 sets) sINOUTSPECIFICATION-AXSOLENOIDS
sINOUTSPECIFICATION-AXSOLENOIDS

: This also includes the number of blanking
ide plate assembly.
Us

: For the product without the SI Unit (S0), note
s
n
tio

the maximum number of solenoids of the SI


ta
S

Unit that will be mounted. If the layout is


23 specified, indicate it on the manifold
1
ide specification sheet.
Ds
Manifold base (5 stations) 2 P, E port entry, SUP/EXH block assembly
SS5Y3-10SQ1C-05D-C6 Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
SS5Y3-10SQ1C-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)

SY3100-5U1 ······················ 3 sets (2-position single part no.)
U side (2 to 10 stations) U C G

SY3200-5U1 ······················ 1 set (2-position double part no.)
D side (2 to 10 stations) D E H

SY3300-5U1 ······················ 1 set (3-position closed center part no.) Both sides (2 to 24 stations) B F J
The asterisk denotes the symbol for assembly.

: 3/5(E) port is plugged for the built-in silencer type.
Prefix it to the part numbers of the valve etc.
: When the built-in silencer type is used, keep the exhaust port from
coming in direct contact with water or other liquids.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement For details about the EX250 Integrated-type (For Input/Output) Serial
becomes complicated, specify on a manifold specification sheet. Transmission System, refer to the WEB catalog or the Best
Pneumatics No. 1 and the Operation Manual. For details about part

: When mixing top ported configurations, select from page 180. numbers of SI Units to be mounted, refer to page 239 in this catalog.
In this case, use caution as there is also output on the A and B port on base side. Please download the Operation Manual via SMC website,
Specify on a manifold specification sheet if plugs are required on the A and B
http://www.smcworld.com
port on base side.
173
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
* A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
- Mounting and Option
Option DIN Rail Option

Manifold Exploded View


Symbol Mounting
Name plate Station number Nil Direct mounting
0 Without DIN rail (with bracket) Type 10, 11, 12
Nil — —
Direct 3 For 3 stations Specify a longer
AA mounting ) )
rail than the total
···

···

BA ) — length of specified
D: — — 24 For 24 stations stations.
DIN rail
A: mounting ) )
B: ) —

: Enter the number of stations inside : when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
Plug Assembly Part No.

: Only direct mounting is available for Type 11 (Bottom ported).


One-touch Fittings/

: Refer to page 271 for the fixation of DIN rail mounting type manifold.

: When it is necessary to mount a DIN rail without an SI Unit, select D0


and order DIN rail length separately, referring to L3 in the dimensions.
(Refer to page 249 for part numbers of DIN rail.)
Manifold Options

Protective class
class  (Mark: )
174
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O.
page 268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC
 Type of mounting screw
) Seal type Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal - Light/surge voltage suppressor K Round head combination screw (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw (Falling-out-prevention type)
Surge voltage Common
: For “K” and “H”, the valve body cover has a
Symbol With light drop prevention construction to stop the
suppressor specification
0 Pilot type R — mounting screws from falling out when the
Nil Internal pilot Non-polar valve is removed for maintenance etc.
U )

: When ordering a valve individually, the
R External pilot
S — Positive base gasket is not included.
)
Z ) common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
1 Back pressure check valve NZ ) common separately if it is needed for maintenance
service.
(Built-in valve type)
: “R" and “U” are applicable for every SI Unit.
Refer to page 244 for part numbers of the
Nil None However, “S” and “Z” can be used only for
base gasket and mounting screw.
CC-Link applicable Unit and “NS” and “NZ”
H Built-in
are for Units which are not CC-Link

: “B” and “H” cannot be selected for the

: Only rubber seal type. Manifold installed type individual SUP/EXH spacer assembly,
applicable.
is available if the back pressure check valve interface regulator or double check spacer

: Only “Z” and “NZ” types are available for with
is required for a valve with metal seal. Refer assembly with residual pressure release
the power saving circuit.
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
175
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX250

C2
U
SS5Y3-10S:::- Stations D - C3, N1
C4, N3 (D)
B C6, N7

Sub-plate
D side U side

(L5) L1 Manual override


1

18 21 63 (
Push-turn locking slotted type:
)

Plug-in
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor)
: Gray (For metal seal)
DIN rail holding screw
DIN rail 2(B) port side : Yellow
(For DIN rail mounting)

(5.5)
(8)
B A B A B A B A B A

Metal Base
(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
0

1
66

60.5
2

(40.9)
3

4.6
12 B 12 B 12 B 12 B 12 B

Plug-in
4.6
2.7

1.7
)
(4.9)

C6: 3.6
N7: 7.4
SI Unit
7.5

2 x M4 Mounting hole Input block 4 x M4 Mounting hole


(
(Fitting for the type with P/E
5.5 L6 L2 1.5 ports on the U and/or D sides)

Manifold Exploded View


Type 50, 51, 52
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting : ø3.2, ø1/8"
[1(P), 3/5(E) port] (Station 1)---(Station n)
: ø4, ø5/32"

Connector Connecting Base


Applicable tube O.D.: ø8, ø5/16" : ø6, ø1/4"

1 P 1 P
0
BUS 63.1
1
10.6

13.6

56.6
60

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

2
PWR
21.6

4 A4 A4 A4 A4 A
3
18

13.2

(For DIN rail


mounting)
(7.5)

Plug-in
M3 (Pitch)
(11.8)

4 x M8 18.3 15.5 P = 10.5 (17.8)


2 x M12
3-pin socket

Manifold Exploded View


Type 10, 11, 12
L1 = 10.5 x n1 + 135.5 + 21 x n2
1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 10.5 x n1 + 42
: These figures show the “SS5Y3-10SQ1A-05D-C6”.
L4 = L3 – 10.5
: Refer to page 210 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 82
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Plug Assembly Part No.
One-touch Fittings/

Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
Manifold Options

1 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5
2 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5
3 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
4 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498
5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523
6 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548
7 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5
8 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5
176
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX250

U C4, N3
SS5Y5-10S:::- Stations D - C6, N7 (D)
B C8, N9

D side U side
(L5) L1
Manual override
1
18 21 63
DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw (Light/surge voltage suppressor) : Gray (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Input block
DIN rail SI Unit

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
0

97.5

113.4
1
66

81.2
3

(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
23.5

10.9
4.7
(5.9)
(8.3)

2 x M4 Mounting hole
4 x M5 Mounting hole
5.5 L6 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
One-touch fitting : ø6, ø1/4"
[1(P), 3/5(E) port] : ø8, ø5/16"
Applicable tube O.D.: ø10, ø3/8"

0
BUS 1 P 1 P

73.2
1 2 B2 B2 B2 B2 B
56.6
60

12.4

13.2

2
33.4

3/5 E 3/5 E
29.1

PWR
3
4 A4 A4 A4 A4 A
14.1
8.7
(For DIN rail

(7.5)
mounting)

M3 (Pitch)
(11.8)

20 18 P = 16 (20.5)
4 x M8 2 x M12
3-pin socket

L1 = 16 x n1 + 141.5 + 21 x n2
1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 16 x n1 + 48
: These figures show the “SS5Y5-10SQ1A-05D-C8”.
L4 = L3 – 10.5
: Refer to page 211 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.5
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498 510.5 523 548 560.5 573
2 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598
3 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623
4 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5
5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 585.5 598 610.5 623 648 660.5
6 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5 685.5
7 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5 648 673 685.5 698
8 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 573 598 610.5 623 648 660.5 673 685.5 710.5 723
177
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX250

C6, N7
U
SS5Y7-10S:::- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side
(L5) L1 Manual override
1

18 21 63 DIN rail holding screw


(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 4(A) port side : Blue (For rubber seal)

Plug-in
(For DIN rail mounting) (Light/surge voltage suppressor) : Gray (For metal seal)
Input 2(B) port side : Yellow
connector
SI Unit
(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
0

1
66

128.8
115

Metal Base
2

(5.5)

96.7
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
38.9

Plug-in
8.8
3.9
(6)

2 x M4 Mounting hole
(9.3)

4 x M5 Mounting hole
(17.9)

(A, B port: ø12)


(Fitting for the type with P/E

Manifold Exploded View


5.5 L6 L2 1.5 ports on the U and/or D sides)

Type 50, 51, 52


(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port ]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"

Connector Connecting Base


[1(P), 3/5(E) port] : ø10, ø3/8"
Applicable tube O.D.: ø12, ø1/2" : ø12

2
82.7
0 1 P 1 P
BUS 2 B2 B2 B2 B2 B
1
56.6
60

13.2
14.2

11.1

2 3/5 E 3/5 E
35.2

8.7

31.6

PWR 4 A4 A4 A4 A4 A
3

Plug-in
(For DIN rail

(10)

M3 (Pitch)
mounting)

25 20.5 P = 19 (21.7)
2 x M12
(14.3)

4 x M8

Manifold Exploded View


3-pin socket Type 10, 11, 12

L1 = 19 x n1 + 149.7 + 21 x n2
1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 19 x n1 + 56
: These figures show the “SS5Y7-10SQ1A-05D-C10”.
L4 = L3 – 10.5
: Refer to page 212 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.7
n1: Valve stations
n2: Input block stations
Plug Assembly Part No.
One-touch Fittings/

L3: DIN Rail Overall Length


Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I/O Unit
stations (n2)
Manifold Options

0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
1 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 548 560.5 585.5 598 623 635.5 660.5
2 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673
3 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698
4 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723
5 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5
6 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 748 760.5
7 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5
8 385.5 398 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798
178
Plug-in Connector Connecting Base
EX250

Series SY3000/5000/7000
Type 12
Top Ported

How to Order Manifold

SS5Y 3 12S Q 05 U
Refer to pages 210 to 212 for
dimensions of Type 12/Top
ported type. / 4 ) 0 1 6 2 *
/ Series 4 SI Unit 1 Valve stations
3 SY3000 0 Without SI Unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Negative common) 02 2 stations

···
7 N

···
SY7000 PROFIBUS DP (Negative common) Double wiring
1
V CC-Link (Positive common) 16 16 stations
TA 2 power 8 in/8 out, 31 slave modes 02 2 stations
AS-Interface supply 4 in/4 out, 31 slave modes Specified layout
2
) Input block stations

···
TB

···
systems
(Negative 1 power (Available up to 32 solenoids)
Nil None TC common) supply
8 in/8 out, 31 slave modes 24 24 stations
1 1 station TD systems 4 in/4 out, 31 slave modes
1: Double wiring: 2-position single, double,
Y CANopen (Negative common) 3-position and 4-position valves can be used
···

···

on all manifold stations.


8 8 stations ZE EtherNet/IP™ (Negative common) Use of a 2-position single solenoid will result in

: Without SI Unit, the symbol is nil. The maximum


: Ensure a match with the common specification an unused control signal. If this is not desired,
number of stations is limited for the AS-Interface of the valve to be used. order with a specified layout.
applicable SI Unit.
: Input block cannot be mounted without SI Unit.
2: Specified layout: Indicate the wiring

: The supply current from the SI Unit of specifications on the manifold specification
AS-Interface applicable 1 power supply system sheet. (Note that 2-position double, 3-position
specification to the input block and valve is and 4-position valves cannot be used where
0 Input block type limited. single wiring has been specified.)
When determining the number of valve
PNP input NPN input stations, note that the maximum number of
(Positive common) (Negative common) solenoids for the AS-Interface applicable SI
Without input block Nil Unit specification is as follows.
sINOUTSPECIFICATION-AXSOLENOIDS
M12, 2 inputs A D sINOUTSPECIFICATION-AXSOLENOIDS
M12, 4 inputs B E
: This also includes the number of blanking plate
M8, 4 inputs C F assembly.

: For the product without the SI Unit (S0), note the

: Without SI Unit, the symbol is nil. maximum number of solenoids of the SI Unit that
will be mounted. If the layout is specified,
indicate it on the manifold specification sheet.

How to Order Manifold Assembly 6 P, E port entry, SUP/EXH block assembly


Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
Example (SS5Y3-12S:-:) U side (2 to 10 stations) U C
1 G
3-position closed
center (24 VDC)
D side (2 to 10 stations) D E
1 H
2-position double (24 VDC) Both sides (2 to 24 stations)
SY3330-5U1-C6 (1 set) B — J
SY3230-5U1-C6 (1 set)

1: For SUP/EXH block assembly specifications, built-in silencer types will have
2-position single (24 VDC) P port entry stipulated.
SY3130-5U1-C6 (3 sets)
: For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is
plugged. The silencer exhaust port is located on the opposite side of P, E port entry.
(Example: When the P, E port entry is D side, the silencer exhaust port is U side.)

: When the built-in silencer type is used, keep the exhaust port from coming in
direct contact with water or other liquids.
ide
Us
2 P, E port size (One-touch fittings)
s
n
tio
ta
S

Symbol SY3000 SY5000 SY7000


2 3
e
1 Nil ø8 ø10 ø12
D sid
N ø5/16" ø3/8" ø1/2"
Manifold base (5 stations)
: For N, sizes are in inches.
SS5Y3-12SQ1C-05D
* Mounting
: If the DIN rail must be mounted
SS5Y3-12SQ1C-05D ··· 1 set (Type 12 5-station manifold base part no.)
Nil Direct mounting without an SI Unit, select D0. Then,

SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) D DIN rail mounting (With DIN rail) refer to L3 of the dimensions for the
D0 DIN rail mounting (Without DIN rail) DIN rail length and order separately.

SY3230-5U1-C6 ··········· 1 set (2-position double part no.) (Refer to page 249 for the DIN rail

SY3330-5U1-C6 ··········· 1 set (3-position closed center part no.) D3 For 3 stations Specify a longer
part number.)
···

···

The asterisk denotes the symbol for assembly. rail than the
: Refer to page 271 for the fixation of
Prefix it to the part numbers of the valve etc. D24 For 24 stations standard length. DIN rail mounting type manifold.

s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE For details about the EX250 Integrated-type (For Input/Output) Serial
sUnder the manifold part number, state the valves to be mounted in order Transmission System, refer to the WEB catalog or the Best Pneumatics No. 1
from the 1st station as shown in the figure above. If the arrangement and the Operation Manual. For details about part numbers of SI Units to be
becomes complicated, specify on a manifold specification sheet. mounted, refer to page 239 in this catalog. Please download the Operation
Manual via SMC website, http://www.smcworld.com

179
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
4 Type of actuation

Metal Base
One-touch fitting (Metric)
1
2-position
Single 2 Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double Nil Standard C2 ø2 ) — —
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
4 3-position Exhaust center
: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
5 Pressure center type when the valve is continuously C6 ø6 ) ) )
A
1 N.C./N.C. energized for long periods of time. C8 ø8 — ) )
4-position
: Be careful of the energizing time when the C10 ø10 — — )
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O. C12 ø12 — — )
page 268 for details.

1: Only rubber seal type is available for the One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve.
* Rated voltage Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


5 24 VDC N1 ø1/8" ) — —
N3 ø5/32" ) ) —
) Seal type N7 ø1/4" ) ) )
N9 ø5/16" — ) )
0 Rubber seal - Light/surge voltage suppressor N11 ø3/8" — — )
1 Metal seal and common specification
Surge voltage Common
Symbol With light
suppressor specification

Connector Connecting Base


0 Pilot type R —
Non-polar
 Thread type
U ) Nil Rc
Nil Internal pilot
S — Positive
) F G
R External pilot
Z ) common N NPT
NS — Negative T NPTF
NZ ) common
: Only Nil is available for M5.
1 Back pressure check valve
: “R" and “U” are applicable for every SI Unit.
(Built-in valve type) However, “S” and “Z” can be used only for
CC-Link applicable Unit and “NS” and “NZ”

Plug-in
Nil None
H Built-in
are for Units which are not CC-Link
applicable.
 Type of mounting screw

: Only “Z” and “NZ” types are available for with
Nil Round head combination screw

: Only rubber seal type. Manifold installed type


B Hexagon socket head cap screw

Manifold Exploded View


is available if the back pressure check valve the power saving circuit.
is required for a valve with metal seal. Refer K Round head combination screw (Falling-out-prevention type) Type 10, 11, 12
to page 256 for Ordering Example. However, H Hexagon socket head cap screw (Falling-out-prevention type)
it is not recommended to use the built-in  Manual override
: For “K” and “H”, the valve body cover has a
valve type and the manifold installed type at Nil: D: drop prevention construction to stop the
the same time because it will reduce the flow. Non-locking Push-turn mounting screws from falling out when the

: The built-in valve type back pressure check push type locking slotted valve is removed for maintenance etc.
valve is not available for the 3-position type type
: When ordering a valve individually, the
and the SY7000. base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
Plug Assembly Part No.
One-touch Fittings/

separately if it is needed for maintenance


service.
E: F: Refer to page 244 for part numbers of the
Push-turn Slide locking base gasket and mounting screw.
locking lever type
: "B" and "H" cannot be selected for the
type individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
180
Plug-in Connector Connecting Base
Type 10
Side Ported EX260

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000)


and 209 (SY7000) for
SS5Y 3 10 S NA N 05 U C6
dimensions of Type
11/Bottom ported type. / 4 ) 0 1 6 2 * -
/ Series 1 Valve stations 6 P, E port entry
3 SY3000 In the case of the 32-output SI Unit U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
···

Double wiring
1
···

16 16 stations
4 Type 02 2 stations 2 SUP/EXH block assembly
10 Side ported Specified layout
2 Nil Internal pilot
···

···

11 Bottom ported
1 (Available up to 32 solenoids)
24 24 stations S Internal pilot, Built-in silencer

1: The SY5000 manifold base is used for the R External pilot


bottom ported of the SY3000. When In the case of the 16-output SI Unit
ordering, refer to “Plug-in Mixed Type Symbol Stations Note
: 3/5(E) port is plugged for the built-in silencer
Manifold” (from page 213). type.
02 2 stations
: When the built-in silencer type is used, keep
···

Double wiring
1
···

the exhaust port from coming in direct contact


08 8 stations
) SI Unit specifications 02 2 stations
with water or other liquids.
Symbol ProtocolNumber of outputs Communication connector Specified layout
2
···

···

0 Without SI Unit (Available up to 16 solenoids)


16 16 stations Refer to the page on the right for *.
QA DeviceNet™
32
M12
1: Double wiring: 2-position single, double,
QB 16
NA 32 3-position and 4-position valves can be
NB PROFIBUS 16
M12 used on all manifold stations. - Mounting and Option
Use of a 2-position single solenoid will Option
NC DP 32
D-sub
1 result in an unused control signal. If this is Symbol Mounting
ND 16 Name plate Station number
not desired, order with a specified layout
VA 32
2: Specified layout: Indicate the wiring
Nil — —
CC-Link M12 Direct
VB 16 specifications on the manifold specification AA mounting
) )
DA 32 sheet. BA ) —
EtherCAT ® M12
DB 16 (Note that 2-position double, 3-position and D: — —
DIN rail
FA 32 4-position valves cannot be used where A: ) )
PROFINET M12 single wiring has been specified.) mounting
FB 16 B: ) —
EA 32
: This also includes the number of blanking
EtherNet/IP™ M12 plate assembly.
: Enter the number of stations inside : when it
EB 16 is larger than the number of valve stations.

: For the model without the SI Unit (S0), note

1: IP40 for the D-sub applicable (Refer to “DIN Rail Option” below.)
the maximum number of solenoids of the SI
communication connector specification.
: Only direct mounting is available for Type 11
Unit that will be mounted. If the layout is
DIN rail cannot be mounted without SI Unit. (Bottom ported).
specified, indicate it on the manifold
specification sheet.
: Refer to page 271 for the fixation of DIN rail
mounting type manifold.

0 SI Unit output polarity DIN Rail Option


Nil Positive common (NPN) Nil Standard length
N Negative common (PNP) 0 Without DIN rail (with bracket)

: Ensure a match with the common 3 For 3 stations


Specify a longer rail than the
···

···

specification of the valve to be used. total length of specified stations.

: Without SI Unit, the symbol is nil. 24 For 24 stations



: When it is necessary to mount a DIN rail
without an SI Unit, select D0 and order DIN
rail length separately, referring to L3 in the
dimensions. (Refer to page 249 for part
numbers of DIN rail.)

For details about the EX260 Integrated-type (For Output)


Serial Transmission System, refer to the WEB catalog or
the Best Pneumatics No. 1 and the Operation Manual. For
details about part numbers of SI Units to be mounted, refer
to page 240 in this catalog. Please download the Operation
Manual via SMC website, http://www.smcworld.com

181
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
* A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
How to Order Manifold Assembly
Manifold Exploded View
Type 10, 11, 12

Example (SS5Y3-10SNAN-:)
SS5Y3-10SNAN-04D-C6···1 set (Type 10 4-station manifold base part no.)
2-position single (24 VDC) 2-position double (24 VDC)
SY3100-5U1·····················2 sets (2-position single part no.)
SY3100-5U1 (2 sets) SY3200-5U1 (1 set)
SY3200-5U1·····················1 set (2-position double part no.)
3-position closed center (24 VDC)
SY3300-5U1·····················1 set (3-position closed center part no.)
SY3300-5U1 (1 set)
The asterisk denotes the symbol for assembly.
Plug Assembly Part No.

Prefix it to the part numbers of the valve etc.


One-touch Fittings/

sThe valve arrangement is numbered as the 1st station from the D side.
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDIN
order from the 1st station as shown in the figure above.
ide If the arrangement becomes complicated, specify on a manifold
Us specification sheet.
s
n
tio

Manifold Options
ta


: When mixing top ported configurations, select from page 188.
S

3 Specify on a manifold specification sheet if plugs are required on the A


2
1 and B port on the manifold.
Manifold base (4 stations) ide
Ds
SS5Y3-10SNAN-04D-C6

Protective class
class  (Mark: )
182
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking slotted

1: Only metal seal type is available for the type
high pressure type.

4 Type of actuation
1
2-position
Single 2 Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center locking lever type

: Be sure to select the power saving circuit
type
5 Pressure center type when a valve is continuously energized
A
1 N.C./N.C. for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
C
1 N.C./N.O. power saving circuit is selected. Refer to
page 268 for details.

1: Only rubber seal type is available for the



: Refer to page 31 for with the safety slide
4-position dual 3-port valve.
locking manual override.
* Rated voltage
5 24 VDC

) Seal type  Type of mounting screw


0 Rubber seal Nil Round head combination screw
1 Metal seal - Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification Round head combination screw
Surge voltage Common K (Falling-out-prevention type)
Symbol With light
suppressor specification
0 Pilot type R — H
Hexagon socket head cap screw
(Falling-out-prevention type)
Nil Internal pilot Non-polar
U )
: For “K” and “H”, the valve body cover has a
R External pilot S — Positive
) drop prevention construction to stop the
Z ) common mounting screws from falling out when the
NS — Negative valve is removed for maintenance etc.
common
: When ordering a valve individually, the
1 Back pressure check valve NZ )
base gasket is not included.
(Built-in valve type)
: Select a valve from R, U, S or Z when the SI
Since the base gasket is attached to the
Unit output polarity is Nil (positive common).
Nil None manifold, please order the base gasket
Select a valve from R, U, NS or NZ when the
H Built-in separately if it is needed for maintenance
SI Unit output polarity is N (negative
service.

: Only rubber seal type. Manifold installed type common).


Refer to page 244 for part numbers of the
is available if the back pressure check valve
: Only “Z” and “NZ” types are available for with
base gasket and mounting screw.
is required for a valve with metal seal. Refer the power saving circuit.

: “B” and “H” cannot be selected for the
to page 256 for details. However, it is not individual SUP/EXH spacer assembly,
recommended to use the built-in valve type interface regulator or double check spacer
and the manifold installed type at the same assembly with residual pressure release
time because it will reduce the flow. valve.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
183
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX260

U C2
D - C3, N1
N3 (D)
B C4,
C6, N7

Sub-plate
D side U side
Manual override
1

(Push-turn locking slotted type:


Press, then rotate it. )

Plug-in
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
: Gray (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
(Light/surge voltage
(DIN rail) suppressor) (8)

(5.5)

Metal Base
B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A

83
80.2
(114.8)

60.5
(40.9)
4.6
12 B 12 B 12 B 12 B

Plug-in
22.2

4.6
1.7
(4.9)

SI Unit 4 x M4 Mounting hole


) C6: 3.6
N7: 7.4

Manifold Exploded View


(Fitting for the type with P/E

Type 50, 51, 52


ports on U and/or D sides)
(

L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting

Connector Connecting Base


One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2
[Communication connector D-sub] Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
(Station 1)----------- (Station n) : ø4, ø5/32"
: ø6, ø1/4"

BUS BUS OUT manual override)


(Slide locking

1 P 1 P 1 P
76.7

76.7

63.1
68.8
10.6
13.6

BUS IN
56.6

3/5 E 2 B2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

Plug-in
PWR 4 A4 PWR
21.6

4 A4 A4 A4 A4 A
18

Manifold Exploded View


46.5 46.5 (17.8)
Type 10, 11, 12
(7.5)
(11.8)

15.5 (Pitch)
P = 10.5

1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10SQA-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.


Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275
Manifold Options

L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

n: Stations 18 19 20 21 22 23 24
L1 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 231 241.5 252 262.5 273 283.5 294
L3 298 310.5 323 335.5 348 348 360.5
L4 287.5 300 312.5 325 337.5 337.5 350
L5 13 14 15 16 17 12 13

184
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX260

U C4, N3
SS5Y5-10S::- D - C6, N7 (D)
B C8, N9

D side U side
Manual override
1

( Push-turn locking slotted type:


Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
(For DIN rail mounting) : Gray (For metal seal)
2(B) port side : Yellow
(Light/surge voltage suppressor)
(DIN rail) (8)

(5.5)
B A B A B A B A

(35)
14 A 14 A 14 A 14 A
(114.8)

97.5
113.4
101

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B

10.9
1.4

4.7
(5.9)
(8.3)

SI Unit
4 x M5 Mounting hole

34.2 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E
(L3) ports on U and/or D sides)

One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.:: ø4, ø5/32"
[Communication connector D-sub] [1(P), 3/5(E) port] : ø6, ø1/4"
Applicable tube O.D.: ø10 (Station 1)----------- (Station n) : ø8, ø5/16"
: ø3/8"

BUS manual override)


(Slide locking

BUS OUT
76.7

1 P
2 B2
78.9
76.7

14.1

1 P 1 P
73.2

3/5 E BUS IN 2 B2 B2 B2 B2 B
56.6

PWR

3/5 3/5
33.4

E E
29.1

4 A4 PWR

4 A4 A4 A4 A4 A

48.2
8.7
12.4

(11.8)

(Pitch) (20.5)
(7.5)

48.2 18 P=16

1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10SQA-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5

n: Stations 18 19 20 21 22 23 24
L1 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 336 352 368 384 400 416 432
L3 410.5 423 435.5 448 473 485.5 498
L4 400 412.5 425 437.5 462.5 475 487.5
L5 17 15 13.5 11.5 16 14.5 12.5

185
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX260

C6, N7
U
SS5Y7-10S::- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side

(L5) L1
DIN rail holding screw Manual override
1
(For DIN rail mounting) Light/surge voltage suppressor
(
Push-turn locking slotted type:
)

Plug-in
Press, then rotate it.
4(A) port side: Blue (For rubber seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
102.3

128.8
115
(5.5)

96.7
(77.1)

Plug-in
12 B 12 B 12 B 12 B 12 B

5.5
14

8.8
3.9
SI Unit
(6)
(9.3)

Manifold Exploded View


(A, B port: ø12) 4 x M5 Mounting hole
(17.9)

Type 50, 51, 52


34.4 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting

Connector Connecting Base


[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
(Station 1) (Station n)
[Communication connector D-sub]
2

BUS OUT
BUS
82.7

1 P 1 P
76.7

1 P 2 B2 B2 B2 B2 B
76.7

BUS IN
2 B2
56.6

Plug-in
11.1

3/5 E 3/5 E
35.2

8.7

31.6

3/5 E PWR 4 A4 A4 A4 A4 A
PWR 4 A4

Manifold Exploded View


14.2

Type 10, 11, 12


(For DIN rail
mounting)
(10)

(21.7)
(14.3)

53.2
(Pitch)
53.2 20.5 P = 19 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
Plug Assembly Part No.
One-touch Fittings/

1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10SQA-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.


Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 550 575
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5
186
Plug-in Connector Connecting Base
EX260
Type 12
Top Ported
Series SY3000/5000/7000 RoHS
How to Order Manifold

Refer to pages 210 to 212


SS5Y 3 12S NA N 05 U
for Type 12/Top ported
dimensions. / 4 ) 0 1 6 2 *
/ Series 0 Valve stations 1 P, E port entry
3 SY3000 In the case of the 32-output SI Unit U
1 U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D
1 D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring
1
···

···


1: 6 For type “S”, supply/exhaust block assembly
4 SI Unit specifications 16 16 stations with built-in silencer, choose U or D for P port
Number of Communication 02 2 stations entry.
Symbol Protocol outputs connector Specified layout
2
···

···

0 Without SI Unit 24 24 stations


(Available up to 32 solenoids) 6 SUP/EXH block assembly
Nil Internal pilot
QA 32 In the case of the 16-output SI Unit
DeviceNet™ M12 S Internal pilot, Built-in silencer
QB 16
Symbol Stations Note
NA 32
R External pilot
M12 02 2 stations
: For built-in silencer type, P and E ports are
NB PROFIBUS 16
Double wiring
1
···

···

available on U and D sides. 3/5(E) port is


NC DP 32 08 8 stations plugged. The silencer exhaust port is located on
D-sub
1
ND 16 02 2 stations the opposite side of P, E port entry. (Example:
VA 32 Specified layout
2 When the P, E port entry is D side, the silencer
···

···

CC-Link M12 exhaust port is U side.)


VB 16 (Available up to 16 solenoids)
16 16 stations
: When the built-in silencer type is used, keep the
DA 32 exhaust port from coming in direct contact with
EtherCAT ® M12
1: Double wiring: 2-position single, double,
DB 16 3-position and 4-position valves can be used water or other liquids.
FA 32 on all manifold stations.
FB
PROFINET
16
M12 Use of a 2-position single solenoid will result in 2 P, E port size (One-touch fittings)
an unused control signal. If this is not desired, Symbol SY3000 SY5000 SY7000
EA 32
EtherNet/IP™ M12 order with a specified layout.
EB 16
2: Specified layout: Indicate the wiring Nil ø8 ø10 ø12

1: IP40 for the D-sub applicable communication specifications on the manifold specification
connector specification. sheet. N ø5/16" ø3/8" ø1/2"
DIN rail cannot be mounted without SI Unit. (Note that 2-position double, 3-position and
: For N, sizes are in inches.
4-position valves cannot be used where single
) SI Unit output polarity wiring has been specified.)

: This also includes the number of blanking plate
* Mounting
Nil Positive common (NPN) assembly. Nil Direct mounting
N Negative common (PNP)
: For the model without the SI Unit (S0), note the D DIN rail mounting (With DIN rail)
maximum number of solenoids of the SI Unit that D0 DIN rail mounting (Without DIN rail)

: Ensure a match with the common specification will be mounted. If the layout is specified,
of the valve to be used. D3 For 3 stations
indicate it on the manifold specification sheet. Specify a longer rail than
···

···

: Without SI Unit, the symbol is nil.


the standard length.
D24 For 24 stations
For details about the EX260 Integrated-type (For Output) Serial Transmission System, refer to the
: When it is necessary to mount a DIN rail without
an SI Unit, select D0 and order DIN rail length
WEB catalog or the Best Pneumatics No. 1 and the Operation Manual. For details about part
separately, referring to L3 in the dimensions.
numbers of SI Units to be mounted, refer to page 240 in this catalog. Please download the Refer to page 249 for part numbers of DIN rail.
Operation Manual via SMC website, http://www.smcworld.com
: Refer to page 271 for the fixation of DIN rail
mounting type manifold.
How to Order Manifold Assembly

Example (SS5Y3-12SNAN-:)
2-position single (24 VDC) 2-position double (24 VDC)
SS5Y3-12SNAN-04D ····· 1 set (Type 12 4-station manifold base part no.)
SY3130-5U1-C6 (2 sets) SY3230-5U1-C6 (1 set)

SY3130-5U1-C6 ············· 2 sets (2-position single part no.)
3-position closed center (24 VDC)
SY3230-5U1-C6 ············· 1 set (2-position double part no.)
SY3330-5U1-C6 (1 set)
SY3330-5U1-C6 ············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.

s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s5NDERTHEMANIFOLDPARTNUMBER STATETHEVALVESTOBEMOUNTEDIN
de
si

order from the 1st station as shown in the figure above.


U
s
n

If the arrangement becomes complicated, specify on a manifold


tio
ta
S

specification sheet.
3
2
1
e

Manifold base (4 stations)


d
si
D

SS5Y3-12SNAN-04D

187
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 2 Coil type  A, B port size
3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000
: Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type when a valve is continuously energized 01 1/8 SY5000
for long periods of time. 02 1/4 SY7000
4 Type of actuation
: Be careful of the energizing time when the

Metal Base
power saving circuit is selected. Refer to One-touch fitting (Metric)
1 Single page 268 for details.
2-position Symbol A, B port SY3000 SY5000 SY7000
2 Double
C2 ø2 ) — —
3 Closed center
4 3-position Exhaust center
* Rated voltage C3 ø3.2 ) — —
5 24 VDC C4 ø4 ) ) —

Plug-in
5 Pressure center
C6 ø6 ) ) )
A
1 N.C./N.C.
4-position C8 ø8 — ) )
B
1 N.O./N.O.
C
1
dual 3-port
N.C./N.O. - Light/surge voltage suppressor C10 ø10 — — )
and common specification C12 ø12 — — )

1: Only rubber seal type is available for the


4-position dual 3-port valve. Surge voltage Common One-touch fitting (Inch)

Manifold Exploded View


Symbol With light
suppressor specification Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


R — N1 ø1/8" ) — —
Non-polar
U )
) Seal type S — Positive
N3
N7
ø5/32" ) ) —
) ø1/4" ) ) )
0 Rubber seal common
Z ) N9 ø5/16" — ) )
1 Metal seal
NS — Negative N11 ø3/8" — — )
NZ ) common

: Select a valve from R, U, S or Z when the SI
0 Pilot type  Thread type

Connector Connecting Base


Unit output polarity is Nil (positive common).
Nil Internal pilot Select a valve from R, U, NS or NZ when the
R External pilot SI Unit output polarity is N (negative Nil Rc
common). F G

: Only “Z” and “NZ” types are available for with N NPT
the power saving circuit. T NPTF
1 Back pressure check valve
: Only Nil is available for M5.
(Built-in valve type)
Nil None  Manual override
H Built-in Nil: D:  Type of mounting screw

Plug-in

: Only rubber seal type. Manifold installed type Non-locking Push-turn


is available if the back pressure check valve push type locking slotted Nil Round head combination screw
is required for a valve with metal seal. Refer type B Hexagon socket head cap screw
to page 256 for details. However, it is not Round head combination screw

Manifold Exploded View


K (Falling-out-prevention type)
recommended to use the built-in valve type
and the manifold installed type at the same Type 10, 11, 12
Hexagon socket head cap screw
time because it will reduce the flow. H (Falling-out-prevention type)

: The built-in valve type back pressure check


valve is not available for the 3-position type E: F:
: For “K” and “H”, the valve body cover has a
and the SY7000. Push-turn Slide locking drop prevention construction to stop the
locking lever type mounting screws from falling out when the
type valve is removed for maintenance etc.
6 Pilot valve option
: When ordering a valve individually, the
base gasket is not included.
Nil Standard (0.7 MPa) Since the base gasket is attached to the
Plug Assembly Part No.

B Quick response type (0.7 MPa)


One-touch Fittings/

manifold, please order the base gasket


K
1 High pressure type (1.0 MPa) separately if it is needed for maintenance

: Refer to page 31 for with the safety slide service.

1: Only metal seal type is available for the locking manual override.
high pressure type. Refer to page 244 for part numbers of the
base gasket and mounting screw.

: “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
Manifold Options

interface regulator.

Protective class
class  (Mark: )
188
Plug-in Connector Connecting Base
Type 10
Side Ported EX126

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000)


and 209 (SY7000) for
SS5Y 3 10 S4 V 05 U C6
dimensions of Type
11/Bottom ported type. / 4 ) 0 1 6 2 *
/ Series 4 Type 0 Valve stations
3 SY3000 10 Side ported Symbol Stations Note
5 SY5000 11 Bottom ported
1 02 2 stations
7 Double wiring
1

···

···
SY7000
1: The SY5000 manifold base is used for the
bottom ported of the SY3000. When 08 8 stations
ordering, refer to “Plug-in Mixed Mounting 02 2 stations
Type Manifold” (from page 213). Specified layout
2

···

···
(Available up to 16 solenoids)
16 16 stations

1: Double wiring: 2-position single, double,
) SI Unit 3-position and 4-position valves can be
0 Without SI Unit used on all manifold stations.
V CC-Link (Positive common NPN) Use of a 2-position single solenoid will
result in an unused control signal. If this is

: Only a terminal block plate is mounted for the
not desired, order with a specified layout.
valve without SI Unit.

2: Specified layout: Indicate the wiring
specifications with the manifold
specification sheet. (Note that 2-position
double, 3-position and 4-position valves
cannot be used where single wiring has
How to Order Manifold Assembly been specified.)

: This also includes the number of blanking
plate assembly.
Example (SS5Y3-10S4V-:-:)
2-position double (24 VDC)
2-position single (24 VDC) SY3200-5U1 (1 set) 1 P, E port entry
SY3100-5U1 (3 sets) U U side (2 to 10 stations)
3-position closed
SI Unit center (24 VDC)
D D side (2 to 10 stations)
SY3300-5U1 (1 set) B Both sides (2 to 16 stations)

6 SUP/EXH block assembly


Nil Internal pilot
ide
Us S Internal pilot, Built-in silencer
s
on R External pilot
ati
St
3
: 3/5(E) port is plugged for the built-in silencer
2 type.
1
ide
: When the built-in silencer type is used, keep
Ds the exhaust port from coming in direct
contact with water or other liquids.
Terminal block plate assembly
Manifold base (5 stations)
SS5Y3-10S4V-05D-C6

SS5Y3-10S4V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)



SY3100-5U1 ··················· 3 sets (2-position single part no.)

SY3200-5U1 ··················· 1 set (2-position double part no.)

SY3300-5U1 ··················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
sUnder the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement For details about the EX126 Integrated-type (For Output)
becomes complicated, specify on a manifold specification sheet. Serial Transmission System, refer to the WEB catalog or

: When mixing top ported configurations, select from page 196. the Best Pneumatics No. 1 and the Operation Manual. For
In this case, use caution as there is also output on the A and B port on base details about part numbers of SI Units to be mounted, refer
side. to page 241 in this catalog. Please download the Operation
Specify on a manifold specification sheet if plugs are required on the A and B
Manual via SMC website, http://www.smcworld.com
port on base side.
189
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
2 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
* Mounting and Option
Option
Symbol Mounting

Manifold Exploded View


Name plate Station number
Nil — — Type 10, 11, 12
Direct
AA mounting
) )
BA ) —
D: — —
DIN rail
A: mounting
) )
B: ) —

: Enter the number of stations inside : when it


is larger than the number of valve stations.
Plug Assembly Part No.

(Refer to “DIN Rail Option” below.)


One-touch Fittings/

: Only direct mounting is available for Type 11


(Bottom ported).

: Refer to page 271 for the fixation of DIN rail


mounting type manifold.

DIN Rail Option


Nil Direct mounting
Manifold Options

0 Without DIN rail (with bracket)


3 For 3 stations Specify a longer rail
···

···

than the total length


16 For 16 stations of specified stations.

Protective class
class  (Mark: )
190
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type

4 Type of actuation
1
2-position
Single 2 Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center
: Be sure to select the power saving circuit lever
5 Pressure center type when the valve is continuously type
A
1 N.C./N.C. energized for long periods of time.
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O.
page 268 for details.
: Refer to page 31 for with the safety slide

1: Only rubber seal type is available for the locking manual override.
4-position dual 3-port valve.
* Rated voltage
5 24 VDC
) Seal type  Type of mounting screw
Nil Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
- Light/surge voltage suppressor K Round head combination screw (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw (Falling-out-prevention type)
Surge voltage Common
: For “K” and “H”, the valve body cover has a
Symbol With light
0 Pilot type suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
Nil Internal pilot R —
Non-polar valve is removed for maintenance etc.
R External pilot U )
: When ordering a valve individually, the
)
S — Positive base gasket is not included.
Z ) common Since the base gasket is attached to the

: Only “Z” type is available for with the power manifold, please order the base gasket
1 Back pressure check valve saving circuit. separately if it is needed for maintenance
(Built-in valve type) service.
Refer to page 244 for part numbers of base
Nil None
gasket and mounting screw.
H Built-in
: “B” and “H” cannot be selected for the

: Only rubber seal type. Manifold installed type individual SUP/EXH spacer assembly,
is available if the back pressure check valve interface regulator or double check spacer
is required for a valve with metal seal. Refer assembly with residual pressure release
to page 256 for Ordering Example. However, valve.
it is not recommended to use the built-in
valve type and the manifold installed type at
the same time because it will reduce the flow.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
191
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX126

U C2
SS5Y3-10S4V- Stations D - C3, N1 ( )
D
B C4, N3 C6, N7

Sub-plate
D side U side
Manual override
1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 4(A) port side : Blue (For rubber seal)

Plug-in
DIN rail : Gray (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
116
42

80

60.5

Metal Base
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B
36.6

4.6
1.7
11

Plug-in
)
(4.9)

15.4
C6: 3.6
N7: 7.4
55.4 4 x M4
Mounting hole
2 x M5 Mounting hole
7.1
1
88.2 ( L2 1.5
(Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)

Manifold Exploded View


(DIN rail mounting hole pitch: 12.5)

Type 50, 51, 52


(L3)

4 x G1/2 One-touch fitting


Signal/Electrical entry [1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
2.6

SI Unit Applicable tube O.D.: ø2


: ø3.2, ø1/8"
(Station 1)---(Station n) : ø4, ø5/32"

Connector Connecting Base


: ø6, ø1/4"
90.7

1 P 1 P
63.1
13.6
10.6

56.6
55.4

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18
13.2

Plug-in
(For DIN rail

33.4
(7.5)

mounting)

(Pitch)
(11.8)

Terminal block plate assembly 107.1 15.5 P = 10.5 (17.8)

Manifold Exploded View


Type 10, 11, 12

1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10S4V-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

192
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX126

U C4, N3
SS5Y5-10S4V - Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override
1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
121.4
116
42

97.5
113.4
80

81.2
(61.7)
5.5
42.4

12 B 12 B 12 B 12 B 12 B

10.9
16.4

4.7
(5.9)
(8.3)

55.4
2 x M5 Mounting hole 4 x M5 Mounting hole

7.1 87.7 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

4 x G1/2 One-touch fitting


Signal/Electrical entry [1(P), 3/5(E) port]
One-touch fitting
Applicable tube O.D.: ø10, ø3/8"
[4(A), 2(B) port]
2.6

SI Unit (Station 1)----------- (Station n) Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
: ø8, ø5/16"
90.7

1 P 1 P
14.1

73.2
8.7

2 B2 B2 B2 B2 B
56.6
55.4

3/5 3/5
33.4

E E
29.1

4 A4 A4 A4 A4 A
13.2
12.4

(For DIN rail

33.4
(7.5)

mounting)

(Pitch)
(20.5)
(11.8)

Terminal block plate assembly 108.8 18 P = 16


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10S4V-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15

193
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX126

U C6, N7
SS5Y7-10S4:- Stations D - C8, N9 ( )
D
B C10, N11 C12
D side U side

Sub-plate
(L5) L1
Manual override
1

DIN rail holding screw DIN rail holding screw (Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
(For DIN rail mounting) (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
116
42

Metal Base
136.8

80

128.8
115
(5.5)

96.7
(77.1)
57.8

12 B 12 B 12 B 12 B 12 B

Plug-in
5.5
31.8

8.8
4 x M5

3.9
(6)
(9.3)

55.4 Mounting hole


2 x M5 Mounting hole (A, B port: ø12)
(17.9)

Manifold Exploded View


1 (Fitting for the type with P/E

Type 50, 51, 52


7.1 87.9 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[1(P), 3/5(E) port]

Connector Connecting Base


Applicable tube O.D.: ø12, ø1/2"

4 x G1/2 SI Unit
(2.6)

(Signal/Electrical entry) (Station 1) (Station n)

2
90.7

82.7

Plug-in
1 P 1 P
2 B2 B2 B2 B2 B
56.6
55.4

11.1

3/5 E 3/5 E
35.2

8.7

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12
13.2
14.2

(For DIN rail


mounting)
(10)

(21.7)
(14.3)

33.4 (Pitch)
Terminal block plate assembly
113.8 20.5 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
Plug Assembly Part No.

: ø10, ø3/8"
One-touch Fittings/

: ø12


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y7-10S4V-05D-C10”.

: Refer to page 212 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

194
Plug-in Connector Connecting Base
EX126
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

Refer to pages 210 to 212


SS5Y 3 12S4 V 05 U
for dimensions of Type
12/Top ported type.
/ 4 ) 0 1 6 2
/ Series ) Valve stations 0 P, E port entry
3 SY3000 Symbol Stations Note U
1 U side (2 to 10 stations)
5 SY5000 02 2 stations D
1 D side (2 to 10 stations)
Double wiring
1
···

···

7 SY7000 B Both sides (2 to 16 stations)


08 8 stations
1: 1 For type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U or
4 SI Unit Specified layout
2 D for P port entry.
···

···

(Available up to 16 solenoids)
0 Without SI Unit 16 16 stations
V CC-Link (Positive common NPN)
1: Double wiring: 2-position single, double,

: Only a terminal block plate is mounted for the 3-position and 4-position valves can be used 1 SUP/EXH block assembly
valve without SI Unit. on all manifold stations. Nil Internal pilot
Use of a 2-position single solenoid will result S Internal pilot, Built-in silencer
in an unused control signal. If this is not External pilot
R
desired, order with a specified layout.

2: Specified layout: Indicate the wiring
: For built-in silencer type, P and E ports are
specifications on the manifold specification available on U and D sides. 3/5(E) port is
sheet. (Note that 2-position double, 3-position plugged. The silencer exhaust port is located
and 4-position valves cannot be used where on the opposite side of P, E port entry.
single wiring has been specified.) (Example: When the P, E port entry is D

: This also includes the number of blanking plate side, the silencer exhaust port is U side.)
assembly.
: When the built-in silencer type is used, keep
the exhaust port from coming in direct
contact with water or other liquids.
How to Order Manifold Assembly

Example (SS5Y3-12S4V-:-:) 6 P, E port size (One-touch fittings)


2-position double (24 VDC) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC) SY3230-5U1-C6 (1 set) Nil ø8 ø10 ø12
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC) N ø5/16" ø3/8" ø1/2"
SI Unit
SY3330-5U1-C6 (1 set)
: For N, sizes are in inches.

2 Mounting
Nil Direct mounting
sid
e D DIN rail mounting (With DIN rail)
U D0 DIN rail mounting (Without DIN rail)
s
at ion
St D3 For 3 stations Specify a longer rail
···

···

2
3 than the standard
1 D16 For 16 stations length.
ide
Ds
: Refer to page 271 for the fixation of DIN rail
mounting type manifold.
Terminal block plate assembly

Manifold base (5 stations)


SS5Y3-12S4V-05D

SS5Y3-12S4V-05D ··· 1 set (Type 12 5-station manifold base part no.)



SY3130-5U1-C6 ········ 3 sets (2-position single part no.)

SY3230-5U1-C6 ········ 1 set (2-position double part no.)

SY3330-5U1-C6 ········ 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
For details about the EX126 Integrated-type (For Output)
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE Serial Transmission System, refer to the WEB catalog or
sUnder the manifold part number, state the valves to be mounted in order the Best Pneumatics No. 1 and the Operation Manual. For
from the 1st station as shown in the figure above. If the arrangement details about part numbers of SI Units to be mounted, refer
becomes complicated, specify on a manifold specification sheet. to page 241 in this catalog. Please download the Operation
Manual via SMC website, http://www.smcworld.com

195
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
4 Type of actuation

Metal Base
One-touch fitting (Metric)
1 Single
2 Coil type Symbol A, B port SY3000 SY5000 SY7000
2-position Nil Standard C2 ø2 ) — —
2 Double
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2 ) — —
4 3-position Exhaust center
: Be sure to select the power saving circuit C4 ø4 ) ) —

Plug-in
type when the valve is continuously C6 ø6 ) ) )
5 Pressure center
energized for long periods of time.
A
1 N.C./N.C. C8 ø8 — ) )
4-position
: Be careful of the energizing time when the
B
1 N.O./N.O. power saving circuit is selected. Refer to C10 ø10 — — )
dual 3-port
C
1 N.C./N.O. page 268 for details. C12 ø12 — — )

1: Only rubber seal type is available for the One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve.
* Rated voltage Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


5 24 VDC N1 ø1/8" ) — —
N3 ø5/32" ) ) —
) Seal type N7 ø1/4" ) ) )
0 N9 ø5/16" — ) )
1
Rubber seal
Metal seal
- Light/surge voltage suppressor N11 ø3/8" — — )
and common specification
Surge voltage Common
Symbol With light

Connector Connecting Base


suppressor specification
0 Pilot type R —  Thread type
Non-polar
Nil Internal pilot U ) Nil Rc
)
R External pilot S — Positive F G
Z ) common N NPT

: Only “Z” type is available for with the power T NPTF
saving circuit.
: Only Nil is available for M5.
1 Back pressure check valve
(Built-in valve type)

Plug-in
Nil None  Manual override
H Built-in
Nil: D:
 Type of mounting screw

: Only rubber seal type. Manifold installed type Non-locking Push-turn Nil Round head combination screw

Manifold Exploded View


is available if the back pressure check valve push type locking slotted B Hexagon socket head cap screw
is required for a valve with metal seal. Refer type Type 10, 11, 12
K Round head combination screw (Falling-out-prevention type)
to page 256 for Ordering Example. However,
it is not recommended to use the built-in H Hexagon socket head cap screw (Falling-out-prevention type)
valve type and the manifold installed type at
: For “K” and “H”, the valve body cover has a
the same time because it will reduce the flow. drop prevention construction to stop the

: The built-in valve type back pressure check mounting screws from falling out when the
valve is not available for the 3-position type E: F: valve is removed for maintenance etc.
and the SY7000. Push-turn Slide locking
: When ordering a valve individually, the
locking lever type base gasket is not included.
type Since the base gasket is attached to the
Plug Assembly Part No.

manifold, please order the base gasket


One-touch Fittings/

separately if it is needed for maintenance


service.
Refer to page 244 for part numbers of base
gasket and mounting screw.

: Refer to page 31 for with the safety slide
: “B” and “H” cannot be selected for the
locking manual override. individual SUP/EXH spacer assembly or
interface regulator.
Manifold Options

Protective class
class  (Mark: )
196
Plug-in Connector Connecting Base
Type 10
Side Ported EX120

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 208 (SY5000)


and 209 (SY7000) for
SS5Y 3 10 S3 R1 05 U C6
dimensions of Type
11/Bottom ported type. / 4 ) 0 1 6 2 *
/ Series ) SI Unit 0 Valve stations
3 SY3000 0 Without SI Unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Positive common NPN) 02 2 stations
Double wiring
1

···

···
7 SY7000 R1 OMRON CompoBus/S 16 outputs
R2 (Positive common NPN) 8 outputs 08 8 stations
V CC-Link (Positive common NPN) 02 2 stations
4 Type Specified layout
2

···

···
ZB
1 Positive common NPN
(Available up to 16 solenoids)
CompoNet™
10 Side ported ZBN
1 Negative common PNP 16 16 stations
11 Bottom ported
1
1: The communication connector (for the
1: Double wiring: 2-position single, double,

1: The SY5000 manifold base is used for the opposite side) is not provided. Please order 3-position and 4-position valves can be
bottom ported of the SY3000. When it separately. used on all manifold stations.
ordering, refer to “Plug-in Mixed Mounting
: Ensure a match with the common Use of a 2-position single solenoid will
Type Manifold” (from page 213). specification of the valve to be used. result in an unused control signal. If this is
not desired, order with a specified layout.

2: Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be
used where single wiring has been
specified.)
How to Order Manifold Assembly
: This also includes the number of blanking
plate assembly.

: Since R2 type SI Unit has 8 outputs, note
Example (SS5Y3-10S3V-:) that up to 8 solenoids can be
accommodated.
2-position double (24 VDC)
2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) 3-position closed 1 P, E port entry
center (24 VDC) U U side (2 to 10 stations)
SY3300-5U1 (1 set) D D side (2 to 10 stations)
B Both sides (2 to 16 stations)

6 SUP/EXH block assembly


Nil Internal pilot
ide S Internal pilot, Built-in silencer
Us
on
s R External pilot
ati
St
: 3/5(E) port is plugged for the built-in silencer
3 type.
2
1
e
D sid
Manifold base (5 stations)
SS5Y3-10S3V-05D-C6

SS5Y3-10S3V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)



SY3100-5U1 ··················· 3 sets (2-position single part no.)

SY3200-5U1 ··················· 1 set (2-position double part no.)

SY3300-5U1 ··················· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
For details about the EX120 Integrated-type (For Output)
Serial Transmission System, refer to the WEB catalog or

: When mixing top ported configurations, select from page 204. the Best Pneumatics No. 1 and the Operation Manual. For
In this case, use caution as there is also output on the A and B port on base details about part numbers of SI Units to be mounted, refer
side.
to page 242 in this catalog. Please download the Operation
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side. Manual via SMC website, http://www.smcworld.com

197
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
Plug-in
2 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2 ) — — — — N1 ø1/8" ) — — — —
C3 ø3.2 ) — — — — N3 ø5/32" ) ) — ) —

Straight

Metal Base
C4 ø4 ) ) — ) — N7 ø1/4" ) ) ) ) )
Straight

C6 ø6 ) ) ) ) ) N9 ø5/16" — ) ) ) )
C8 ø8 — ) ) ) ) N11 ø3/8" — — ) — )
C10 ø10 — — ) — ) CM
1 Straight port, mixed sizes ) ) ) ) )

Plug-in
C12 ø12 — — ) — ) LN3 ø5/32" ) — — — —

Upward
CM
1 Straight port, mixed sizes ) ) ) ) ) LN7 ø1/4" ) ) — — —
L4 ø4 ) ) — — — LN9 ø5/16" — ) — — —
L6 ø6 ) ) ) — — LN11 ø3/8" — — ) — —
Upward

Elbow
2

L8 ø8 — ) ) — — BN3 ø5/32" ) — — — —
Downward

Manifold Exploded View


L10 ø10 — — ) — — BN7 ø1/4" ) ) — — —

Type 50, 51, 52


L12 ø12 — — ) — — BN9 ø5/16" — ) — — —
Elbow
2

B4 ø4 ) ) — — — BN11 ø3/8" — — ) — —
Downward

B6 ø6 ) ) ) — — Elbow port, mixed sizes


LM
1 (Including upward and ) ) ) — —
B8 ø8 — ) ) — — downward piping)

B10 ø10 — — ) — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — — ) — — (One-touch fittings)

Connector Connecting Base


Elbow port, mixed sizes
LM
1 (Including upward and ) ) ) — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

1: Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting
direction.

2: To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 250 to 252).

Plug-in
* Mounting and Option
Option
Symbol Mounting

Manifold Exploded View


Name plate Station number
Nil — — Type 10, 11, 12
Direct
AA mounting
) )
BA ) —
D: — —
DIN rail
A: mounting
) )
B: ) —

: Enter the number of stations inside : when it


is larger than the number of valve stations.
Plug Assembly Part No.

(Refer to “DIN Rail Option” below.)


One-touch Fittings/

: Only direct mounting is available for Type 11


(Bottom ported).

: Refer to page 271 for the fixation of DIN rail


mounting type manifold.

DIN Rail Option


Nil Direct mounting
Manifold Options

0 Without DIN rail (with bracket)


3 For 3 stations Specify a longer rail
···

···

than the total length


16 For 16 stations of specified stations.

: When it is necessary to mount a DIN rail


without an SI Unit, select D0 and order DIN
rail length separately, referring to L3 in the
dimensions. (Refer to page 249 for part Protective class
numbers of DIN rail.) class  (Mark: )
198
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type
4 Type of actuation
1
2-position
Single 2 Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center
: Be sure to select the power saving circuit locking type
5 Pressure center type when the valve is continuously lever
A
1 N.C./N.C. energized for long periods of time. type
4-position
: Be careful of the energizing time when the
B
1 dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to
C
1 N.C./N.O.
page 268 for details.

1: Only rubber seal type is available for the


: Refer to page 31 for with the safety slide
4-position dual 3-port valve. locking manual override.
* Rated voltage
5 24 VDC
) Seal type  Type of mounting screw
0 Rubber seal Nil Round head combination screw
1 Metal seal - Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification K Round head combination screw (Falling-out-prevention type)
Surge voltage Common H Hexagon socket head cap screw (Falling-out-prevention type)
0 Pilot type Symbol With light
suppressor specification

: For “K” and “H”, the valve body cover has a
Nil Internal pilot R — drop prevention construction to stop the
Non-polar
R External pilot U ) mounting screws from falling out when the
S —
)
Positive valve is removed for maintenance etc.
Z ) common
: When ordering a valve individually, the
1 Back pressure check valve NS — Negative base gasket is not included.
(Built-in valve type) common Since the base gasket is attached to the
NZ )
manifold, please order the base gasket
Nil None
: Select a valve from R, U, S or Z when the SI separately if it is needed for maintenance
H Built-in Unit specification is positive common. Select service.

: Only rubber seal type. Manifold installed type a valve from R, U, NS or NZ when the SI Unit Refer to page 244 for part numbers of the
is available if the back pressure check valve specification is ZBN (negative common). base gasket and mounting screw.
is required for a valve with metal seal. Refer
: Only “Z” and “NZ” types are available for with
: “B” and “H” cannot be selected for the
to page 256 for Ordering Example. However, the power saving circuit. individual SUP/EXH spacer assembly,
it is not recommended to use the built-in interface regulator or double check spacer
valve type and the manifold installed type at assembly with residual pressure release
the same time because it will reduce the flow. valve.

: The built-in valve type back pressure check


valve is not available for the 3-position type
and the SY7000.

Protective class
class  (Mark: )
199
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000 Connector Connecting Base EX120

C2
U
SS5Y3-10S3:- Stations D - C3, N1
C4, N3 (D)
B C6, N7

Sub-plate
D side U side
Manual override
1
DIN rail holding screw (L5) L1
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A
64
83
6.2

60.5

Metal Base
(40.9)
12 B 12 B 12 B 12 B 12 B

M3
Terminal screw
16.1

4.6

1.7
4.6

)
(4.9)
C6: 3.6
N7: 7.4

Plug-in
4 x M4 Mounting hole
(
(Fitting for the type with P/E
27.9 L2 1.5
ports on the U and/or D sides)
(5.3) (L4)

Manifold Exploded View


(DIN rail mounting hole pitch: 12.5)

Type 50, 51, 52


(L3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting
(Station 1)---(Station n) : ø3.2, ø1/8"
[1(P), 3/5(E) port]
: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16"
: ø6, ø1/4"

1 P 1 P

Connector Connecting Base


63.1
10.6
13.6

56.6
61

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


(7.5)

mounting)

(Pitch)
(11.8)

39.7 15.5 P = 10.5 (17.8)

Plug-in
Manifold Exploded View
Type 10, 11, 12

1: Refer to page 205 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y3-10S3V-05D-C6”.

: Refer to page 210 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 96.9 107.4 117.9 128.4 138.9 149.4 159.9 170.4 180.9 191.4 201.9 212.4 222.9 233.4 243.9
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 123 135.5 148 160.5 173 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273
L4 112.5 125 137.5 150 162.5 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5
L5 13 14 15 16 17 12 13 14 15 16 17 11.5 12.5 13.5 14.5

200
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX120

U C4, N3
SS5Y5-10S3:- Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override
1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
M3 DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
Terminal screw 2(B) port side : Yellow

(5.5)
(8)
6.2

BA BA BA BA BA

(35)
64

14 A 14 A 14 A 14 A 14 A
97.5

113.4
81.2
(61.7)
36.9

5.5
12 B 12 B 12 B 12 B 12 B
10.9

4.7
(5.9)
(8.3)

4 x M5 Mounting hole

30.2 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
One-touch fitting (Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6
61

14.1
33.4

3/5 E 3/5 E
29.1

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


(7.5)

mounting)

(Pitch)
(11.8)

44.2 18 P = 16 (20.5)


1: Refer to page 206 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

: These figures show the “SS5Y5-10S3V-05D-C8”.

: Refer to page 211 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 116.7 132.7 148.7 164.7 180.7 196.7 212.7 228.7 244.7 260.7 276.7 292.7 308.7 324.7 340.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373
L4 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5
L5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16

201
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base EX120

C6, N7
U
SS5Y7-10S3:- Stations D - C8, N9
C10, N11 (D)
B C12

Sub-plate
D side U side
Manual override
1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting)

Plug-in
4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side: Yellow

(8)
(DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
64
6.2

Metal Base
128.8
115
(5.5)

96.7
(77.1)
50.8

M3 12 B 12 B 12 B 12 B 12 B

5.5

Plug-in
Terminal screw

8.8
3.9
(6)
(9.3)

(17.9)

(A, B port: ø12) 4 x M5 Mounting hole

Manifold Exploded View


Type 50, 51, 52
(Fitting for the type with P/E
28.9 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


(Station 1) (Station n)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
2
82.7

1 P 1 P
2 B2 B2 B2 B2 B
56.6
61

11.1

3/5 E 3/5 E
35.2

8.7

31.6

4 A4 A4 A4 A4 A

Plug-in
14.2

(For DIN rail


(10)

(21.7)
mounting)

Manifold Exploded View


(14.3)

(Pitch)
47.7 20.5 P = 19 Type 10, 11, 12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12


1: Refer to page 207 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.


: These figures show the “SS5Y7-10S3V-05D-C10”.
One-touch Fittings/


: Refer to page 212 for dimensions of A or B port top-ported type.
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 129.4 148.4 167.4 186.4 205.4 224.4 243.4 262.4 281.4 300.4 319.4 338.4 357.4 376.4 395.4
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 335.5 348 373 385.5 410.5 423
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 325 337.5 362.5 375 400 412.5
L5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14

202
Plug-in Connector Connecting Base
EX120
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

Refer to pages 210 to 212


SS5Y 3 12S3 R1 05 U
for dimensions of Type
12/Top ported type.
/ 4 ) 0 1 6 2
/ Series ) Valve stations 0 P, E port entry
3 SY3000 Symbol Stations Note U
1 U side (2 to 10 stations)
5 SY5000 02 2 stations D
1 D side (2 to 10 stations)
Double wiring
1 B
···

···

7 SY7000 Both sides (2 to 16 stations)


08 8 stations
1: 1 For type “S”, supply/exhaust block
02 2 stations assembly with built-in silencer, choose U or
Specified layout
2
4 SI Unit D for P port entry.
···

···

(Available up to 16 solenoids)
0 Without SI Unit 16 16 stations
Q DeviceNet™ (Positive common NPN)
1: Double wiring: 2-position single, double,
R1 OMRON CompoBus/S 16 outputs 3-position and 4-position valves can be used 1 SUP/EXH block assembly
R2 (Positive common NPN) 8 outputs on all manifold stations. Nil Internal pilot
Use of a 2-position single solenoid will result
V CC-Link (Positive common NPN) S Internal pilot, Built-in silencer
in an unused control signal. If this is not
ZB
1 Positive common NPN desired, order with a specified layout. R External pilot
CompoNet™
ZBN
1 Negative common PNP
2: Specified layout: Indicate the wiring
: For built-in silencer type, P and E ports are

1: The communication connector (for the specifications on the manifold specification available on U and D sides. 3/5(E) port is
opposite side) is not provided. Please order sheet. (Note that 2-position double, 3-position plugged. The silencer exhaust port is located
it separately. and 4-position valves cannot be used where on the opposite side of P, E port entry.

: Ensure a match with the common single wiring has been specified.) (Example: When the P, E port entry is D
specification of the valve to be used.
: This also includes the number of blanking plate side, the silencer exhaust port is U side.)
assembly.

: Since R2 type SI Unit has 8 outputs, note that
up to 8 solenoids can be accommodated.

How to Order Manifold Assembly 6 P, E port size (One-touch fittings)


Symbol SY3000 SY5000 SY7000
Example (SS5Y3-12S3V-:) Nil ø8 ø10 ø12
2-position double (24 VDC)
N ø5/16" ø3/8" ø1/2"
SY3230-5U1-C6 (1 set)
2-position single (24 VDC)
: For N, sizes are in inches.
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC)
SY3330-5U1-C6 (1 set)
2 Mounting
Nil Direct mounting
D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a longer rail
ide
···

···

Us than the standard


s
on D16 For 16 stations length.
ati
St
3
: When mounted on the DIN rail without the SI
2 Unit, please select D0 and refer to L3 of the
1
Manifold base e dimensions for the DIN rail length, then order
(5 stations) D sid
separately. (Refer to page 249 for the DIN
SS5Y3-12S3V-05D rail part number.)

: Refer to page 271 for the fixation of DIN rail
SS5Y3-12S3V-05D ··· 1 set (Type 12 5-station manifold base part no.) mounting type manifold.

SY3130-5U1-C6 ······· 3 sets (2-position single part no.)

SY3230-5U1-C6 ······· 1 set (2-position double part no.)

SY3330-5U1-C6 ······· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
For details about the EX120 Integrated-type (For Output)
Prefix it to the part numbers of the valve etc.
Serial Transmission System, refer to the WEB catalog or
s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE the Best Pneumatics No. 1 and the Operation Manual. For
sUnder the manifold part number, state the valves to be mounted in order details about part numbers of SI Units to be mounted, refer
from the 1st station as shown in the figure above. If the arrangement to page 242 in this catalog. Please download the Operation
becomes complicated, specify on a manifold specification sheet. Manual via SMC website, http://www.smcworld.com

203
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 6 Pilot valve option  A, B port size
3 SY3000 Nil Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K
1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000

1: Only metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
4 Type of actuation

Metal Base
One-touch fitting (Metric)
1 Single
2
2-position
Double 2 Coil type Symbol
C2
A, B port
ø2
SY3000 SY5000 SY7000
) — —
3 Closed center Nil Standard
C3 ø3.2 ) — —
4 3-position Exhaust center T With power saving circuit (Continuous duty type)
C4 ø4 ) ) —

Plug-in
5 Pressure center
: Be sure to select the power saving circuit
type when the valve is continuously C6 ø6 ) ) )
A
1 N.C./N.C.
C8 ø8 — ) )
4-position energized for long periods of time.
B
1 dual 3-port
N.O./N.O.
C10 ø10 — — )

: Be careful of the energizing time when the
C
1 N.C./N.O.
power saving circuit is selected. Refer to C12 ø12 — — )

1: Only rubber seal type is available for the page 268 for details.
4-position dual 3-port valve. One-touch fitting (Inch)

Manifold Exploded View


Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


* Rated voltage N1 ø1/8" ) — —
) Seal type 5 24 VDC N3 ø5/32" ) ) —
0 Rubber seal N7 ø1/4" ) ) )
1 Metal seal N9 ø5/16" — ) )
- Light/surge voltage suppressor N11 ø3/8" — — )
and common specification
0 Pilot type Symbol With light
Surge voltage Common
 Thread type

Connector Connecting Base


suppressor specification
Nil Internal pilot
R External pilot R — Nil Rc
Non-polar
U ) F G
S —
)
Positive N NPT
Z ) common
1 Back pressure check valve NS — Negative
T NPTF
(Built-in valve type)
: Only Nil is available for M5.
NZ ) common
Nil None

: Select a valve from R, U, S or Z when the SI
H Built-in
Unit specification is positive common. Select  Type of mounting screw

Plug-in

: Only rubber seal type. Manifold installed type a valve from R, U, NS or NZ when the SI Unit
is available if the back pressure check valve specification is ZBN (negative common). Nil Round head combination screw
is required for a valve with metal seal. Refer
: Only “Z” and “NZ” types are available for with B Hexagon socket head cap screw
to page 256 for Ordering Example. However, the power saving circuit. K Round head combination screw (Falling-out-prevention type)

Manifold Exploded View


it is not recommended to use the built-in Hexagon socket head cap screw (Falling-out-prevention type)
H Type 10, 11, 12
valve type and the manifold installed type at
the same time because it will reduce the flow.  Manual override
: For “K” and “H”, the valve body cover has a
drop prevention construction to stop the

: The built-in valve type back pressure check


valve is not available for the 3-position type Nil: D: mounting screws from falling out when the
and the SY7000. Non-locking Push-turn valve is removed for maintenance etc.
push type locking slotted
: When ordering a valve individually, the
type base gasket is not included.
Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance
Plug Assembly Part No.

service.
One-touch Fittings/

Refer to page 244 for part numbers of the


E: F: base gasket and mounting screw.
Push-turn Slide locking
: “B” and “H” cannot be selected for the
locking lever type individual SUP/EXH spacer assembly or
type interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
204
Series SY3000/5000/7000
Common Dimensions
Plug-in Type 10/Side Ported

Series SY3000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y3-10:- Stations D (S, R)- LB:
B
D side U side
One-touch fitting 7.4 85.5
[PE: Pilot EXH port] (For 5 stations)
[X: External pilot port]
(73.2) (7.4) (11.6)
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

5.3
PE PE
LOCK

X X
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A

(127.8)
58.5
FREE

40.9
1P 1P
12 B 12 B 12 B 12 B 12 B

11.6

6.9
1.7

17.3
27.6
35.2

2(B) port (Fitting for the type with P/E


ports on the U and/or D sides)
70.6 1(P) port 4(A) port
3/5(E) port
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16" : ø6, ø1/4"

(Station 1)---(Station n)
External pilot for straight piping
P, E port entry: D

manual override)
7.4 85.5

(Slide locking
1 P
(For 5 stations)
(65.4)

68.8
63.1
56.6
(43.2)

3/5 E

PE
LOCK

X
B A B A B
14 A 14 A 14
)
)
L6 : 32.4
LN7 : 34.9
L6 : 43.4
LN7 : 45.9
FREE

(Pitch)
(42.8)
(37.5)

1P
12 B 12 B
15.5 P= 10.5 (17.8)
(
(

: These figures show the “SS5Y3-10F2-05DR-L6”.
78.6 One-touch fitting
82.3 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32"

Built-in silencer Downward (Type B)


<Internal pilot>
[SUP/EXH block] [Valve]
P, E port entry: D

Silencer (Exhaust port)


(Built-in silencer specification)
LOCK

LOCK
FREE

FREE
LOCK

B A B A B (11.2)
14 A 14 A 14

4(A) port
3/5(E) port
FREE

12 B 12 B
2(B) port

1(P) port
(0.2)
(7.2) (15)
Plug
3/5(E) port

205
Common Dimensions Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Series SY5000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y5-10:- Stations D (S, R)- LB: One-touch fitting D side U side
B 118.2
[PE: Pilot EXH port]
[X: External pilot port] (For 5 stations)

Sub-plate
(65.4) (12)
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

Plug-in
LOCK

PE PE
3/5 B A B A B A B A B A 3/5

26.9
14 A 14 A 14 A 14 A 14 A

113.4
E E
FREE

X X
1 1

(159.5)

61.7
52.8
P P
12 B 12 B 12 B 12 B 12 B

4.7
12.6
17.9

Metal Base
28.6
36.9

(Fitting for the type with P/E


2(B) port ports on the U and/or D sides)

Plug-in
1(P) port
External pilot for straight piping 4(A) port One-touch fitting
(118.2) 3/5(E) port [4(A), 2(B) port]
P, E port entry: D
(For 5 stations) One-touch fitting Applicable tube O.D.: ø4
(20n) : ø6, ø1/4"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" : ø8, ø5/16"

Manifold Exploded View


(Station 1)----------- (Station n)

Type 50, 51, 52


PE
LOCK

3/5 BA BA
14 A 14 A

E
FREE

X
1

manual override)
(59.8)

(Slide locking
P
(31.7)

12 B 12 B 12 B

78.9
1 P
66.1
(59.8)

(54.3)
(39.3)
(38.8)

3/5 E

Connector Connecting Base


70.8 One-touch fitting
4 A4 A4 A4 A4 A
74.5 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32" (Pitch)
18 P = 16 (20.5)
Built-in silencer
P, E port entry: D
Silencer (Exhaust port)

: These figures show the “SS5Y5-10F2-05DR-L8”.
(Built-in silencer specification)

Plug-in
LOCK

BA BA

Manifold Exploded View


14 A 14 A

Type 10, 11, 12


FREE

12 B 12 B 12 B

Valve/Series SY3000 (Mixed Mounting)


Plug
Downward (Type B) Upward (Type U)
3/5(E) port
Plug Assembly Part No.

Downward (Type B)
One-touch Fittings/

[SUP/EXH block] [Valve]


LOCK

LOCK

One-touch fitting
[4(A), 2(B) port]
FREE

FREE
LOCK

LOCK

Applicable tube O.D.: ø4, ø5/32"


( B6 : 10.7
BN7 : 13.2 ) : ø6, ø1/4"
Manifold Options
FREE

FREE

6.5

16.9

4(A) port

2(B) port ( L6 : 32.9


LN7 : 35.4 )
( B6 : 9.7
BN7 : 7.2 )
(11.1) (3.9)
( L6 : 53.3
LN7 : 55.8 )
(14) (7)

206
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Series SY7000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y7-10:- Stations D (S, R)- LB:
B
One-touch fitting D side U side
[PE: Pilot EXH port] 138.1
[X: External pilot port]
(69.5) (For 5 stations) (10.9)
Applicable tube O.D.: ø6, ø1/4"
(Fitting for the type with P/E
ports on the U and/or D sides)

PE PE
LOCK

3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A

49.4
128.8
FREE

(175.6)
1P 1P

(77.1)
X X

45.4
12 B 12 B 12 B 12 B 12 B

15.6
3.9

34.6
37.6
16.6

(Fitting for the type with P/E


1(P) port ports on the U and/or D sides)
3/5(E) port One-touch fitting
One-touch fitting 4(A) port [4(A), 2(B) port]
Applicable tube O.D.: ø12
[1(P), 3/5(E) port] 2(B) port
External pilot for straight piping Applicable tube O.D.: ø12, ø1/2"
P, E port entry: D One-touch fitting
[4(A), 2(B) port]
(138.1)
Applicable tube O.D.: ø6, ø1/4"
(For 5 stations) : ø8, ø5/16"
(20n) : ø10, ø3/8"

(Slide locking manual override)


(Station 1) (Station n)
PE
LOCK

3/5E B A B A
14 A 14 A

(For ø10, ø3/8")


FREE

85.8
1 P

(For ø12)
69.7

(53.1)

(58)
1P
(For ø10, ø3/8")
(For ø12)
(74.2)
(23.5)

(37.5)
(32.6)

3/5 E

12 B 12 B

(Pitch)
77.7 One-touch fitting 20.5 P = 19 (21.7)
82.7 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø6, ø1/4"

: These figures show the “SS5Y7-10F2-05DR-LM”.
Built-in silencer
P, E port entry: D Downward (Type B)
[SUP/EXH block] [Valve]
Silencer (Exhaust port)
(Built-in silencer specification)
LOCK

LOCK
LOCK

B A B A
FREE

FREE

14 A 14 A
FREE

12 B 12 B

3/5(E) port 4(A) port


Plug 2(B) port
3/5(E) port 1(P) port
(7.3) (13.7) ( ø10: 15.3
ø12: 10.4 ) ( ø10: 5.2
ø12: 10.1 )
207
Common Dimensions Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Valve
Series SY5000 Connector Connecting Base All Wirings

U
SS5Y5-11:- Stations D D side U side
B L2 1.5 Manual override

(
Push-turn locking slotted type:
)

Sub-plate
Press, then rotate it.
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side : Yellow

Plug-in
4 x M5 Mounting hole
LOCK
BA BA BA BA B A
14 A 14 A 14 A 14 A 14 A

97.5
113.4
FREE

5.5

Metal Base
12 B 12 B 12 B 12 B 12 B

10.9
4.7
External pilot
(118.2) (Station 1) ---------- (Station n)

Plug-in
P, E port entry: D
(For 5 stations)
(20n)

manual override)
(Slide locking
78.9
73.2
LOCK

PE

Manifold Exploded View


3/5 B A B A

Type 50, 51, 52


8.7
14 A 14 A

4.7
E
FREE

X
1
(59.8)

(12.9)

(9.5)
P
(Fitting for the type with P/E
(31.7)

12 B 12 B 12 B
ports on the U and/or D sides)

120.5

Connector Connecting Base


70.8 One-touch fitting
(For 5 stations)
74.5 [PE: Pilot EXH port]
[X: External pilot port] (Pitch)
Applicable tube O.D.: ø4, ø5/32" 18 P = 16 (20.5)
4.7

Built-in silencer
31.8

39.7

P, E port entry: D Silencer (Exhaust port) 3/5 E 3/5 E


(Built-in silencer specification) 2 B2 B2 B2 B2 B
18

15

Plug-in
1 P 1 P
4 A4 A4 A4 A4 A
LOCK

Fitting dimensions for panel mounting

Manifold Exploded View


BA BA
14 A 14 A Refer to panel fitting dimensions
for details. Type 10, 11, 12
FREE

One-touch fitting One-touch fitting


12 B 12 B 12 B [1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø10, ø3/8" Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Plug
Plug Assembly Part No.
One-touch Fittings/

Panel fitting dimensions


: These figures show the “SS5Y5-11F2-05D-C8”.

: Refer to the below pages for L2 dimensions and other dimensions that are
not specified in each wiring specification.
7

D-sub connector <IP40> : P. 101


D-sub connector <IP67> : P. 104
Flat ribbon cable : P. 107
60

Manifold Options

Terminal block box : P. 119


97.5

Lead wire : P. 129


Circular connector : P. 139
EX500 (128 points) : P. 149
EX500 (64 points) : P. 155
EX600 : P. 166, 167
L2 EX250 : P. 177
4 x M5 Mounting hole EX260 : P. 185
4 x ø5.5 EX126 : P. 193
EX120 : P. 201
208
Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Series SY7000 Connector Connecting Base All Wirings

U L2
SS5Y7-11:- Stations D D side 1.5 U side
B Manual override

( Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side:
Blue (For rubber seal)
Gray (For metal seal)
2(B) port side : Yellow

LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

115
FREE

12 B 12 B 12 B 12 B 12 B

5.5
8.8
External pilot
P, E port entry: D (138.1) 4 x M5 Mounting hole
(For 5 stations)
40.1 (20n) (Station 1) (Station n)

(Slide locking manual override)


2
PE
LOCK

3/5E B A B A

85.8
82.7
14 A 14 A

56.6
FREE

8.7
1P
(74.2)

12 B 12 B

9.1
(12)
(14.5)
(23.5)

X
(23.9)

(A, B port: ø12) (Fitting for the type with P/E


One-touch fitting ports on the U and/or D sides)
77.7 117
[PE: Pilot EXH port] (For 5 stations)
82.7
[X: External pilot port]
Applicable tube O.D.: ø6, ø1/4" (Pitch)
39.5 20.5 P = 19 (21.7)
3.9

Built-in silencer
P, E port entry: D
Silencer (Exhaust port)
39.9

(Built-in silencer specification)


48.7

3/5 E 3/5 E

2 B2 B2 B2 B2 B
21

19.5
LOCK

B A B A 4 A4 A4 A4 A4 A
14 A 14 A
1 P 1 P
FREE

Fitting dimensions for panel mounting


Refer to panel fitting dimensions
Plug for details.
12 B 12 B

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø12, ø1/2"Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
Panel fitting dimensions : ø12

: These figures show the “SS5Y7-11F2-05D-C10”.

: Refer to the below pages for L2 dimensions and other dimensions
16

that are not specified in each wiring specification.


D-sub connector <IP40>: P. 102
D-sub connector <IP67>: P. 105
Flat ribbon cable : P. 108
60

Terminal block box : P. 120


115

Lead wire : P. 130


Circular connector : P. 140
EX500 (128 points) : P. 150
EX500 (64 points) : P. 156
EX600 : P. 168, 169
EX250 : P. 178
4 x M5 EX260 : P. 186
L2 Mounting hole EX126 : P. 194
4 x ø5.5 EX120 : P. 202
209
Common Dimensions Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Valve
Series SY3000 Connector Connecting Base All Wirings

U
SS5Y3-12:- Stations D (R)
B
D side U side
89.3

Sub-plate
(For 5 stations) Light/surge voltage suppressor

One-touch fitting (External pilot) (Pitch) Manual override


[PE: Pilot EXH port] 16 P = 10.5
(
Push-turn locking slotted type:
)

Plug-in
[X: External pilot port] Press, then rotate it.
7.4 (15.3)
Applicable tube O.D.: ø4, ø5/32" 4(A) port side : Blue (For rubber seal)
(73.2) : Gray (For metal seal)
2(B) port side : Yellow

5.3
PE PE
LOCK

X X
3/5E B A B A B A B A B A 3/5E

92.6
4A 4A 4A 4A 4A

Metal Base
15

11

60.5
58.5
FREE
(40.9)

1P 1P
31.8

30.2
2B 2B 2B 2B 2B

Plug-in
1.7
One-touch fitting

(A/B port, side ported)


[1(P), 3/5(E) port]
(Fitting for the type with P/E
Applicable tube O.D.: ø8, ø5/16"
M5 x 0.8 ) C6: 3.6
N7: 7.4
ports on the U and/or D sides)

[4(A), 2(B) port] One-touch fitting

Manifold Exploded View


(
[4(A), 2(B) port]

Type 50, 51, 52


Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

(Station 1)---(Station n)

Connector Connecting Base


)C6: 77.3
N7: 81.1

1 P 1 P
(73.8)

3/5 E 2 B2 B2 B2 B2 B 3/5 E
(

4 A4 A4 A4 A4 A

Plug-in

: These figures show the “SS5Y3-12F2-05D”.

: For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.

Manifold Exploded View


Refer to page 205 for dimensions of silencer. Type 10, 11, 12

: Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector <IP40>: P. 100
D-sub connector <IP67>: P. 103
Flat ribbon cable : P. 106
Terminal block box : P. 118
Lead wire : P. 128
Circular connector : P. 138
EX500 (128 points) : P. 148
EX500 (64 points) : P. 154
Plug Assembly Part No.
One-touch Fittings/

EX600 : P. 164, 165


EX250 : P. 176
EX260 : P. 184
EX126 : P. 192
EX120 : P. 200
Manifold Options

210
Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Series SY5000 Connector Connecting Base All Wirings

U
SS5Y5-12:- Stations D (R)
B
D side U side
Light/surge voltage suppressor
123.6
(For 5 stations)

(Pitch) Manual override


78.9 (17.4)
(Slide locking
manual override)
5.4
21.1 P = 16
(5.4)
(
Push-turn locking slotted type:
Press, then rotate it. )
One-touch fitting (External pilot) 4(A) port side : Blue (For rubber seal)
(65.4) [PE: Pilot EXH port] : Gray (For metal seal)
[X: External pilot port] 2(B) port side : Yellow
Applicable tube O.D.: ø4, ø5/32"
26.5

PE PE
LOCK

BA BA BA BA B A
3/5 3/5
26.9

4A 4A 4A 4A 4A

113.4
116.7
E E
FREE

X X
1 1

81.2
(61.7)

01 : 16.2
C:: 14.5
52.8

P P

47.3
39.5

2B 2B 2B 2B 2B

One-touch fitting
2.7

(Fitting for the type with P/E


4.7

[1(P), 3/5(E) port] ports on the U and/or D sides)


Applicable tube O.D.: ø10, ø3/8" 1/8
[4(A), 2(B) port] One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

(Station 1)----------- (Station n)


(91.3)
76.9

1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 3/5 E

4 A4 A4 A4 A4 A


: These figures show the “SS5Y5-12F2-05D”.

: For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 206 for dimensions of silencer.

: Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector <IP40>: P. 101
D-sub connector <IP67>: P. 104
Flat ribbon cable : P. 107
Terminal block box : P. 119
Lead wire : P. 129
Circular connector : P. 139
EX500 (128 points) : P. 149
EX500 (64 points) : P. 155
EX600 : P. 166, 167
EX250 : P. 177
EX260 : P. 185
EX126 : P. 193
EX120 : P. 201

211
Common Dimensions Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Valve
Series SY7000 Connector Connecting Base All Wirings

U
SS5Y7-12:- Stations D (R)
B

Sub-plate
One-touch fitting
(External pilot) D side U side
[PE: Pilot EXH port] (Light/surge voltage suppressor)
[X: External pilot port]
144.3 Manual override
Applicable tube O.D.: ø6, ø1/4"

Plug-in
85.8
(Slide locking manual override)
(Pitch)
26.1 P = 19
(For 5 stations)
(17.1)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(69.5) 6.2 (6.2) : Gray (For metal seal)
2(B) port side: Yellow

PE PE
LOCK

3/5E B A B A B A B A B A 3/5E

Metal Base
4A 4A 4A 4A 4A
(49.4)
21

128.8
133.2
FREE

22.6
96.7
1P 1P
(77.1)

Plug-in
X X
59.9
(45.5)

46.4
2B 2B 2B 2B 2B
2.4

One-touch fitting 1/4 4 x M5 Mounting hole


3.9

Manifold Exploded View


[1(P), 3/5(E) port] [4(A), 2(B) port] One-touch fitting

Type 50, 51, 52


Applicable tube O.D.: ø12, ø1/2"
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
(Station 1) (Station n) : ø10, ø3/8"
: ø12
(A, B port: ø12)
(Fitting for the type with P/E
ports on the U and/or D sides)

Connector Connecting Base


(112.1)
(100.3)
88.8

1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

3/5 E 3/5 E
8.7

4 A4 A4 A4 A4 A

Plug-in
Manifold Exploded View
(For DIN rail
(10)

Type 10, 11, 12


mounting)
(14.3)


: These figures show the “SS5Y7-12F2-05D”.

: For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 207 for dimensions of silencer.

: Refer to the below pages for dimensions that are not specified in each wiring specification.
Plug Assembly Part No.
One-touch Fittings/

D-sub connector <IP40>: P. 102


D-sub connector <IP67>: P. 105
Flat ribbon cable : P. 108
Terminal block box : P. 120
Lead wire : P. 130
Circular connector : P. 140
EX500 (128 points) : P. 150
Manifold Options

EX500 (64 points) : P. 156


EX600 : P. 168, 169
EX250 : P. 178
EX260 : P. 186
EX126 : P. 194
EX120 : P. 202

212
0LUG IN #ONNECTOR#ONNECTING"ASE0LUG IN-IXED-OUNTING4YPE-ANIFOLD
$ SUB#ONNECTOR)0 &LAT2IBBON#ABLE 0#7IRING 4ERMINAL"LOCK"OX)0
Type 10 ,EAD7IRE)0 #IRCULAR#ONNECTOR)0 %8)0 %8)0
Side Ported %8)0 %8)0 %8)0 %8

Series SY3000/5000
Type 11
"OTTOM0ORTED

4HE39CANBEMOUNTEDONTOTHE
39SIZEMANIFOLD (OWTO/RDER-ANIFOLD
2EFERTOPAGEFOR
DIMENSIONSOF4YPE
"OTTOMPORTEDTYPE
SS5Y5 M 10 F 1 05 U C 8 6
-IXED-OUNTING4YPE
)TISPOSSIBLETOMOUNTTHE39SIZEVALVESONALLSTATIONS
/ 4 ) 0 1 6 2 * - 
)NTHISCASE THEREISNONEEDTOFILLINPARTINTHEORDERCODE
(OWEVER THEMANIFOLDBLOCKWIDTHSHOULDBEMM

/ Type 0 6ALVESTATIONS 6 350%8(BLOCKASSEMBLY


10 Side ported Symbol Stations Note Nil Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation Internal pilot,
on the number of stations. Refer S Built-in silencer
···

···

to the pages shown in the table


24 24 stations “Connector type” for details. R External pilot
4 Connector type
: 3/5(E) port is plugged for the built-in silencer
Connector
Symbol type Type Page type.
F D-sub connector
(25 pins)
IP40 1 P, E port entry
: Refer to page 161 for the EX600 and 2 on
page 173 for the EX250.
&7 IP67
U U side (2 to 10 stations)
P 26 pins
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins 97
B Both sides (2 to 24 stations)
0( 10 pins

: Refer to page 161 for the EX600 and 2 on
J PC wiring —
page 173 for the EX250.
G (20 pins) With power supply terminal
T Terminal block box 115
L1 34 cores 2 &ITTINGTYPE/NE TOUCHFITTING
L2 Lead wire 17 cores 125 Symbol A, B port
L3 9 cores C Straight
M Circular connector 135 L Metric size Upward
2
Elbow
EX500 Gateway B Downward
2
Decentralized N Straight
S: System 2
145
LN Inch size Upward
2
(128 Points) Elbow
BN Downward
2
EX500 Gateway CM
1 Straight
Mixed sizes
Decentralized LM
1 Elbow (Including upward and downward piping)
2
S: Serial
System
151
transmission
1: Indicate the sizes on the manifold specification sheet in the case of
(64 Points) “CM”, “LM”.
S6: EX600 161 The direction of P, E port fittings is the same as for A, B port. If
S: EX250 173 selecting “LM”, indicate it on the manifold specification sheet for the P,
E port fitting direction.
S: EX260 181
2: To avoid interference with the body or piping, select downward elbow
S4: EX126 189 port when mounting the optional spacer assembly (pages 250 to 252).
S3: EX120 197 Elbow fittings are not available for Type 11 (Bottom ported).

: Refer to the pages shown in the table above


: Elbow fittings: ø2, ø3.2 and ø1.8" are not available for the SY3000
for details. series. ø2, ø3.2, ø1.8" and ø5/32" are not available for the SY5000
series.
)
s7ITH,EADWIRE
Lead wire length
1 0.6 m
2 1.5 m
3 3m

s7ITH$ SUBCONNECTOR)0 &LAT


RIBBONCABLEAND0#WIRING
Connector entry direction
1 Upward
2 Lateral

: It is not necessary to select the items above


for the valve with terminal block box or with
circular connector or the serial transmission
type.
213
Plug-in Connector Connecting Base Series SY3000/5000

Valve
Sub-plate
Plug-in
* SY5000: A, B port size  Mounting
(Metric/One-touch fitting) (Inch/One-touch fitting) Nil Direct mounting
Symbol Port size Symbol Port size D DIN rail mounting (With DIN rail)
4 ø4 3 ø5/32" D0 DIN rail mounting (Without DIN rail)
6 ø6 7 ø1/4" D3 For 3 stations Specify a longer rail than the standard length.

Metal Base
···

···
8 ø8 9 ø5/16" [The SY5000 valve is now at a mountable length
Nil For all stations of SY3000 Nil For all stations of SY3000 D24 For 24 stations (manifold block length of 16 mm).]

: No symbol needs to be specified when fitting type “CM”, “LM” is


: Only direct mounting is available for Type 11 (Bottom ported).
selected.
: Refer to page 220 to determine the L3 using “Calculation formula” for
the DIN rail length.

Plug-in

: Refer to page 271 for the fixation of DIN rail mounting type manifold.
- SY3000: A, B port size
(Metric/One-touch fitting) (Inch/One-touch fitting)
Symbol Port size Symbol Port size
2 ø2 1 ø1/8"
3 ø3.2 3 ø5/32"

Manifold Exploded View


4 ø4 7 ø1/4"

Type 50, 51, 52


6 ø6 9 ø5/16"
1
8 ø8
1

1: The valve pitch is the same as the SY5000.

: No symbol needs to be specified when fitting type “CM”, “LM” is


selected.

Connector Connecting Base


How to Order Manifold Assembly

Example (SS5Y5-M10F1-:)
2-position double

Plug-in
2-position double SY3200-5U1 (2 sets)
SY5200-5U1 (3 sets) Manifold base (5 stations)
SS5Y5-M10F1-05D-C86

Manifold Exploded View


Type 10, 11, 12

ide
Us
o ns
ati
St
3
2
1
e
sid
Plug Assembly Part No.
One-touch Fittings/

SS5Y5-M10F1-05D-C86 ··· 1 set (Type M10 5-station manifold base part no.)

SY5200-5U1 ····················· 3 sets (2-position double part no.)

SY3200-5U1 ····················· 2 sets (2-position double part no.)
The asterisk denotes the symbol for assembly.
Manifold Options

Prefix it to the part numbers of the valve etc.


s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 226.


In this case, use caution as there is also output on the A and B port on base
side.
Protective class
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
class  (Mark: )
214
Series SY3000/5000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


3 SY3000 Nil Standard (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type
4 Type of actuation
1 Single
2
2-position
Double 2 Coil type E: F:
3 Closed center Nil Standard Push-turn Slide locking
4 3-position Exhaust center T With power saving circuit (Continuous duty type) locking type
5 Pressure center
: Be sure to select the power saving circuit lever
A
1 N.C./N.C. type when the valve is continuously type
4-position energized for long periods of time.
B
1 dual 3-port
N.O./N.O.
C
1 N.C./N.O.
: Be careful of the energizing time when the
power saving circuit is selected. Refer to

1: Only rubber seal type is available for the page 268 for details.
: Refer to page 31 for with the safety slide
4-position dual 3-port valve. locking manual override.

* Rated voltage
) Seal type 5 24 VDC  Type of mounting screw
0 Rubber seal 6 12 VDC Nil Round head combination screw
1 Metal seal
: Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type)

0 Pilot type - Light/surge voltage suppressor


: For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
Nil Internal pilot and common specification mounting screws from falling out when the
R External pilot Symbol With light
Surge voltage Common valve is removed for maintenance etc.
suppressor specification
: When ordering a valve individually, the
Nil — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
1 Back pressure check valve U )
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance
S —
)
Positive service.
Nil None Z ) common Refer to page 244 for part numbers of the
H Built-in NS — Negative base gasket and mounting screw.

: Only rubber seal type. Manifold installed type NZ ) common


: “B” and “H” cannot be selected for the
is available if back pressure check valve is
: “Nil” is not available for the SI Unit manifold. individual SUP/EXH spacer assembly,
required for the valve with metal seal. Refer
: Only “Z” and “NZ” types are available for with interface regulator or double check spacer
to page 256 for Ordering Example. However, the power saving circuit. Select a valve which assembly with residual pressure release
it is not recommended to use the built-in is suited to the SI Unit output polarity or SI valve.
valve type and the manifold installed type at Unit specification when the SI Unit is
the same time because it will reduce the flow. selected.

: The built-in valve type back pressure check Refer to the pages below for details.
valve is not available for the 3-position type. EX500: P.147, 153 EX600: P.163
EX250: P.175 EX260: P.183
EX126: P.191 EX120: P.199

Protective class
class  (Mark: )
215
216
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
0LUG IN #ONNECTOR#ONNECTING"ASE0LUG IN-IXED-OUNTING4YPE-ANIFOLD
$ SUB#ONNECTOR)0 &LAT2IBBON#ABLE 0#7IRING 4ERMINAL"LOCK"OX)0
Type 10 ,EAD7IRE)0 #IRCULAR#ONNECTOR)0 %8)0 %8)0
Side Ported %8)0 %8)0 %8)0 %8

Series SY5000/7000
Type 11
"OTTOM0ORTED

4HE39CANBEMOUNTEDONTOTHE
39SIZEMANIFOLD (OWTO/RDER-ANIFOLD
2EFERTOPAGEFOR
DIMENSIONSOF4YPE
"OTTOMPORTEDTYPE
SS5Y7 M 10 F 1 05 U C 10 8
-IXED-OUNTING4YPE
)TISPOSSIBLETOMOUNTTHE39SIZEVALVESONALLSTATIONS
/ 4 ) 0 1 6 2 * - 
)NTHISCASE THEREISNONEEDTOFILLINPARTINTHEORDERCODE
(OWEVER THEMANIFOLDBLOCKWIDTHSHOULDBEMM

/ Type 0 6ALVESTATIONS 6 350%8(BLOCKASSEMBLY


10 Side ported Symbol Stations Note Nil Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation Internal pilot,
on the number of stations. Refer S Built-in silencer
···

···

to the pages shown in the table


24 24 stations “Connector type” for details. R External pilot
4 Connector type
: 3/5(E) port is plugged for the built-in silencer
Connector
Symbol type Type Page type.
F D-sub connector
(25 pins)
IP40 1 P, E port entry
: Refer to page 161 for the EX600 and 2 on
page 173 for the EX250.
&7 IP67
U U side (2 to 10 stations)
P 26 pins
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins 97
B Both sides (2 to 24 stations)
0( 10 pins

: Refer to page 161 for the EX600 and 2 on
J PC wiring —
page 173 for the EX250.
G (20 pins) With power supply terminal
T Terminal block box 115
L1 34 cores 2 &ITTINGTYPE/NE TOUCHFITTING
L2 Lead wire 17 cores 125 Symbol A, B port
L3 9 cores C Straight
M Circular connector 135 L Metric size Upward
2
Elbow
EX500 Gateway B Downward
2
Decentralized N Straight
S: System 2
145
LN Inch size Upward
2
(128 Points) Elbow
BN Downward
2
EX500 Gateway CM
1 Straight
Mixed sizes
Decentralized LM
1 Elbow (Including upward and downward piping)
2
S: Serial
System
151
transmission
1: Indicate the sizes on the manifold specification sheet in the case of
(64 Points) “CM”, “LM”.
3: EX600 161 The direction of P, E port fittings is the same as for A, B port. If
S: EX250 173 selecting “LM”, indicate it on the manifold specification sheet for the P,
E port fitting direction.
S: EX260 181
2: To avoid interference with the body or piping, select downward elbow
S4: EX126 189 port when mounting the optional spacer assembly (pages 250 to 252).
S3: EX120 197 Elbow fittings are not available for Type 11 (Bottom ported).

: Refer to the pages shown in the table above


: Elbow fittings: ø1/4" and ø5/16" are not available.
for details.

)
s7ITH,EADWIRE
Lead wire length
1 0.6 m
2 1.5 m
3 3m

s7ITH$ SUBCONNECTOR)0 &LAT


RIBBONCABLEAND0#WIRING
Connector entry direction
1 Upward
2 Lateral

: It is not necessary to select the items above


for the valve with terminal block box or with
circular connector or the serial transmission
type.
217
Plug-in Connector Connecting Base Series SY5000/7000

Valve
Sub-plate
Plug-in
* SY7000: A, B port size  Mounting and Option
(Metric/One-touch fitting) (Inch/One-touch fitting) Option DIN Rail Option
Symbol Mounting Nil Direct mounting
Symbol Port size Symbol Port size Name plate Station number
6 ø6 7 ø1/4" Nil — — 0 Without DIN rail (with bracket)
Direct 3 For 3 stations Specify a longer rail
8 ø8 9 ø5/16" AA mounting ) )

···

···
than the total length

Metal Base
10 ø10 11 ø3/8" BA ) —
12 ø12 Nil For all stations of SY5000 D: — — 24 For 24 stations of specified stations.
DIN rail
Nil For all stations of SY5000 A: mounting ) )

: No symbol needs to be specified when fitting type “CM”, “LM” is B: ) —


selected.
: Enter the number of stations inside : when it is larger than the number

Plug-in
of valve stations. (Refer to “DIN Rail Option” above.)

: Only direct mounting is available for Type 11 (Bottom ported).
- SY5000: A, B port size
: Refer to page 220 to determine the L3 using “Calculation formula” for
(Metric/One-touch fitting) (Inch/One-touch fitting) the DIN rail length. (For the SY3000 and SY5000 mixed mounting type)
Symbol Port size Symbol Port size
: The manifold block width is 19 mm for both the SY5000 and SY7000
6 ø6 ø1/4" sizes.
7

Manifold Exploded View



: Refer to page 271 for the fixation of DIN rail mounting type manifold.
8 ø8 9 ø5/16"

Type 50, 51, 52


10 ø10 11 ø3/8"
12 ø12

: The valve pitch is 19 mm, the same as the SY7000.

: No symbol needs to be specified when fitting type “CM”, “LM” is


selected.

Connector Connecting Base


How to Order Manifold Assembly

Example (SS5Y7-M10F1-:)
2-position double
SY5200-5U1 (2 sets)

Plug-in
2-position double
SY7200-5U1 (3 sets) Manifold base (5 stations)
SS5Y7-M10F1-05D-C128

Manifold Exploded View


Type 10, 11, 12

ide
Us
s
at ion
St
3
2
1
Plug Assembly Part No.

ide
One-touch Fittings/

Ds

SS5Y7-M10F1-05D-C128 ·· 1 set (Type M10 5-station manifold base part no.)



SY7200-5U1 ····················· 3 sets (2-position double part no.)

SY5200-5U1 ····················· 2 sets (2-position double part no.)
The asterisk denotes the symbol for assembly.
Manifold Options

Prefix it to the part numbers of the valve etc.


s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
s Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

: When mixing top ported configurations, select from page 226.


In this case, use caution as there is also output on the A and B port on base
side.
Protective class
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
class  (Mark: )
218
Series SY5000/7000

How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 7 1 0 0 5 1
/ 4 ) 0 1 6 2 * -  
Base mounted

/ Series 6 Pilot valve option  Manual override


5 SY5000 Nil Standard (0.7 MPa) Nil: D:
7 SY7000 B Quick response type (0.7 MPa) Non-locking Push-turn
K
1 High pressure type (1.0 MPa) push type locking

1: Only metal seal type is available for the slotted
high pressure type. type
4 Type of actuation
1 Single
2
2-position
Double 2 Coil type E: F:
3 Closed center Nil Standard Push-turn Slide locking
4 3-position Exhaust center T With power saving circuit (Continuous duty type) locking type
5 Pressure center
: Be sure to select the power saving circuit lever
A
1 N.C./N.C. type when the valve is continuously type
4-position energized for long periods of time.
B
1 dual 3-port
N.O./N.O.
C
1 N.C./N.O.
: Be careful of the energizing time when the
power saving circuit is selected. Refer to

1: Only rubber seal type is available for the page 268 for details.
: Refer to page 31 for with the safety slide
4-position dual 3-port valve. locking manual override.

* Rated voltage
) Seal type 5 24 VDC  Type of mounting screw
0 Rubber seal 6 12 VDC Nil Round head combination screw
1 Metal seal
: Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type)

0 Pilot type - Light/surge voltage suppressor


: For “K” and “H”, the valve body cover has a
drop prevention construction to stop the
Nil Internal pilot and common specification mounting screws from falling out when the
R External pilot Symbol With light
Surge voltage Common valve is removed for maintenance etc.
suppressor specification
: When ordering a valve individually, the
Nil — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
1 Back pressure check valve U )
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance
S —
)
Positive service.
Nil None Z ) common Refer to page 244 for part numbers of the
H Built-in NS — Negative base gasket and mounting screw.

: Only rubber seal type. Manifold installed type NZ ) common


: “B” and “H” cannot be selected for the
is available if back pressure check valve is
: “Nil” is not available for the SI Unit manifold. individual SUP/EXH spacer assembly,
required for the valve with metal seal. Refer
: Only “Z” and “NZ” types are available for with interface regulator or double check spacer
to page 256 for Ordering Example. However, the power saving circuit. Select a valve which assembly with residual pressure release
it is not recommended to use the built-in is suited to the SI Unit output polarity or SI valve.
valve type and the manifold installed type at Unit specification when the SI Unit is
the same time because it will reduce the flow. selected.

: The built-in valve type back pressure check Refer to the pages below for details.
valve is not available for the 3-position type EX500: P.147, 153 EX600: P.163
and the SY7000. EX250: P.175 EX260: P.183
EX126: P.191 EX120: P.199

Protective class
class  (Mark: )
219
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Valve
Dimensions: Series SY3000/5000 Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M10:- Stations D D side U side
B Manual override
(L5) L1
(
Push-turn locking slotted type:
)

Sub-plate
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Gray (For metal seal)
2(B) port side : Yellow

Plug-in
8

5.5
LOCK

B A B A B A B A B A

35
14 A 14 A 14 A 14 A 14 A

97.5

113.4
FREE

81.2
12 B 12 B
(61.7)

61.7

Metal Base
5.5
12 B 12 B
10.9

4 x M5

4.7
(5.9)
(8.3)
Mounting hole

Plug-in
21.9 L2 1.5 (Fitting for the type with P
and E ports on both sides)
5.3 (L4)
(DIN rail mounting hole pitch: 12.5)
(L3) One-touch fitting
(Station 1)--------- (Station n) [4(A), 2(B) port]

Manifold Exploded View


One-touch fitting
Applicable tube O.D.: ø2

Type 50, 51, 52


[4(A), 2(B) port] Compatible with mixed : ø3.2, ø1/8"
Applicable tube O.D.: ø4, ø5/32" mounting type: ø8, ø5/16" : ø4, ø5/32"
: ø6, ø1/4"

(Slide locking manual override)


SY3000 : ø6, ø1/4"
: ø8, ø5/16"

(SY3000)

(SY3000)
11.1

31.5

78.9
1 P 1 P

73.2
2 B2 B2 B2 B2 B

Connector Connecting Base


8.7

3/5 3/5
33.4

E 4 A4 A4 A E
4 A4 A
12.4

14.1
(SY5000 and SY3000: ø8, ø5/16")
29.1
(SY5000 and SY3000: ø8, ø5/16")
(11.8)
(For DIN rail mounting)
(7.5)

One-touch fitting 35.9 18 (20.5)


[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" ( Pitch of
SY5000 ) ( Pitch of
SY3000 )
P = 16 P = 12.5
Calculation formula for dimensions with

Plug-in
D-sub connector <IP40>, Flat ribbon cable
and PC wiring ( Pitch of SY3000: ø8,
ø5/16" ) One-touch fitting
[4(A), 2(B)port]
P = 16 Applicable tube O.D.: ø8, ø5/16"
L1 = 12.5 x n1 + 16 x n2 + 76.4

Manifold Exploded View


L2 = 12.5 x n1 + 16 x n2 + 48
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated. Type 10, 11, 12
L3 = 12.5 x M + 23
L4 = L3 – 10.5
L5 = (L3 – L1 + 6.1)/2
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000
: Refer to pages 205 and 206 for
(Including the stations of the SY3000: ø8, ø5/16") dimensions of external pilot,
built-in silencer and elbow fittings.
Calculation formula for dimensions with D-sub
connector <IP67>, Terminal block box, Lead
Plug Assembly Part No.

wire, Circular connector,


One-touch Fittings/

EX500/600/250/260/126/120 serial transmission


L1 = 12.5 x n1 + 16 x n2 + a + b x n3
L2 = 12.5 x n1 + 16 x n2 x 48 Coefficient a b c
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 D-sub connector <IP67> 90.5 — —
L4 = L3 – 10.5 Terminal block box or Serial transmission: EX126 149.3 — —
L5 = (L3 – L1)/2
Manifold Options

Lead wire or Circular connector 97 — —


L6 = b x n3 + c
EX500 Gateway Decentralized System 2 (128 Points) 88.7 — —
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 EX500 Gateway Decentralized System (64 Points) 88.5 — —
(Including the stations of the SY3000: ø8, ø5/16") Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O Units or input block stations
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5

: Refer to pages 166 and 167 for dimensions of the
EX600 serial transmission with I/O Unit and page Serial transmission: EX250 141.5 21 81.5
177 for the EX250 serial Serial transmission: EX260 88.7 — —
transmission with input block when L6, b and
c are used for the calculation formula. Serial transmission: EX120 84.7 — —
220
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000/7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M10:- Stations D
B
D side U side Manual override

(L5) L1 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw : Gray (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Light/surge voltage suppressor (8)

(DIN rail)
LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

128.8
115

SY5000: 95.7
SY7000: 96.7
FREE

(5.5)
(35)
(77.1)

12 B 12 B 12 B

12 B 12 B

5.5
8.8

3.9
(6)
(9.3)

(17.9)

(A, B port: ø12)


4 x M5 Mounting hole

(Fitting for the type with P/E


20.7 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting (For SY5000)
[4(A), 2(B) port]
Applicable tube O.D.: ø6 ,ø1/4"
(Station 1) (Station n)
: ø8 ,ø5/16"
: ø10,ø3/8"
: ø12
manual override)
(Slide locking
85.8
82.7

1 P 1 P
2 B2 B2 B2 B2 B
11.1

3/5 E 3/5 E
8.7
35.2

31.6

4 A4 A4 A4 A4 A
14.2

(10)

(For DIN rail


mounting)

(21.7)
(14.3)

One-touch fitting 39.5 20.5


[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2" (Pitch) (Pitch)
P = 19 P = 19

One-touch fitting (For SY7000)


[4(A),2(B) port]
Applicable tube O.D.: ø6 ,ø1/4"
: ø8 ,ø5/16"
: ø10,ø3/8"
: ø12

: Refer to page 207 for dimensions of external pilots and built-in silencers.

: Refer to the below pages for L1, L2, L3, L4 dimensions and other dimensions that are not specified in each wiring specification.
D-sub connector <IP40>: P. 102
D-sub connector <IP67>: P. 105
Flat ribbon cable : P. 108
Terminal block box : P. 120
Lead wire : P. 130
Circular connector : P. 140
EX500 (128 points) : P. 150
EX500 (64 points) : P. 156
EX600 : P. 168, 169
EX250 : P. 178
EX260 : P. 186
EX126 : P. 194
EX120 : P. 202

221
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Valve
Dimensions: Series SY3000/5000 Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M11:- Stations D D side U side
B L1
Manual override

Sub-plate
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal) 4 x M5 Mounting hole
: Gray (For metal seal)

Plug-in
2(B) port side : Yellow

LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

97.5
113.4
FREE

81.2

Metal Base
12 B 12 B

5.5
12 B 12 B

10.9

Plug-in
21.9 L2 1.5
(Station 1)--------- (Station n)
Compatible with mixed
mounting type: ø8, ø5/16"
Panel fitting dimensions
SY3000

Manifold Exploded View


manual override)

Type 50, 51, 52


(Slide locking
7

78.9
73.2
60

97.5

4.7

(SY3000)
(12.9)

(SY5000)

(Fitting for the type with P

(7.3)

Connector Connecting Base


(9.5)

and E ports on both sides)


L2 4 x M5 Mounting hole (Pitch of SY3000: ø8, ø5/16")
4 x ø5.5 P=16
(Pitch of SY5000) (Pitch of SY3000)
P=16 P=12.5
4.7

35.9 18 (20.5)
)
SY5000 and

Calculation formula for dimensions


ø8, ø5/16"
31.8

SY3000:

(SY3000)

Plug-in
39.7

49.6

3/5
L1 = 12.5 x n1 + 16 x n2 + a + b x n3 3/5 E E
2 B2 B2 B
L2 = 12.5 x n1 + 16 x n2 + 48
) (
18

L6 = b x n3 + c 2 B2 B

Manifold Exploded View


Fitting dimensions for panel mounting
n1: Number of valve stations of the SY3000 Refer to panel fitting dimensions 1 P
4 A4 A4 A
1 P Type 10, 11, 12
(SY3000)

4 A4 A
SY5000 and

n2: Number of valve stations of the SY5000 for details.


ø8, ø5/16"
SY3000:

11

(Including the stations of the SY3000:


15

ø8, ø5/16")
n3: Number of I/O Units or input block stations One-touch fitting
(


: Refer to pages 166 and 167 for dimen- [1(P), 3/5(E) port]
sions of the EX600 serial transmission with Applicable tube O.D.: ø10, ø3/8" One-touch fitting
I/O Unit and page 177 for the EX250 serial One-touch fitting [4(A), 2(B) port]
transmission with input block when L6, b [4(A), 2(B) port] Applicable tube O.D.: ø2
Plug Assembly Part No.
One-touch Fittings/

and c are used for the calculation formula. Applicable tube O.D.: ø4, ø5/32" : ø3.2, ø1/8"
: ø6, ø1/4" : ø4, ø5/32"
: ø8, ø5/16" One-touch fitting : ø6, ø1/4"
[4(A), 2(B) port]
Coefficient a b c Applicable tube O.D.: ø8, ø5/16"
D-sub connector <IP40>, Flat ribbon cable or PC wiring 76.4 — —
D-sub connector <IP67> 90.5 — —
Manifold Options

Terminal block box or Serial transmission: EX126 149.3 — —


Lead wire or Circular connector 97 — —
EX500 Gateway Decentralized System 2 (128 Points) 88.7 — —
: Refer to page 208 for dimensions of external pilots
EX500 Gateway Decentralized System (64 Points) 88.5 — — and built-in silencers.
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
222
Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Dimensions: Series SY5000/7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M11:- Stations D D side U side
B
L1
Manual override

(Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor)
: Gray (For metal seal)
2(B) port side: Yellow

LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

128.8
115

SY5000: 95.7
SY7000: 96.7
FREE

12 B 12 B 12 B

12 B 12 B

5.5
8.8

20.7 L2 1.5 4 x M5 Mounting hole

(Station 1) (Station n)

(Slide locking manual override)


Panel fitting dimensions

2
16

85.8
82.7
56.6
9.1
60

115

(12)
(14.5)
(23.9)

(Fitting for the type with P/E


(A, B port: ø12) ports on the U and/or D sides)

L2 4 x M5 Mounting hole
4 x ø5.5 (Pitch) (Pitch)
39.5 20.5 P = 19 P = 19 (21.7)
3.9
39.9

48.7

3/5 E 3/5 E

2 B2 B2 B2 B2 B
21

19.5

4 A4 A4 A4 A4 A

1 P 1 P

Fitting dimensions for panel


One-touch fitting mounting
[1(P), 3/5(E) port] Refer to panel fitting
Applicable tube O.D.: ø12,ø1/2" dimensions for details.

: Refer to page 209 for dimensions of external pilots and built-in silencers. One-touch fitting (For SY7000) One-touch fitting (For SY5000)

: Refer to the below pages for L1, L2 dimensions and other dimensions [4(A), 2(B) port] [4(A), 2(B) port]
that are not specified in each wiring specification. Applicable tube O.D.: ø6 ,ø1/4" Applicable tube O.D.: ø6 ,ø1/4"
: ø8 ,ø5/16" : ø8 ,ø5/16"
Dimensions of Type 11/Bottom ported: P. 209
: ø10,ø3/8" : ø10,ø3/8"
D-sub connector <IP40> : P. 102 : ø12 : ø12
D-sub connector <IP67> : P. 105
Flat ribbon cable : P. 108
Terminal block box : P. 120
Lead wire : P. 130
Circular connector : P. 140
EX500 (128 points) : P. 150
EX500 (64 points) : P. 156
EX600 : P. 168, 169
EX250 : P. 178
EX260 : P. 186
EX126 : P. 194
EX120 : P. 202
223
224
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
D-sub Connector (IP40/67) Flat Ribbon Cable PC Wiring Terminal Block Box (IP67)
Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67) EX600 (IP67)
EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

Type 12
Top Ported
Series SY3000/5000/7000
For the SY5000 series, the SY5000 and the SY3000
can be mounted on the same manifold.
For the SY7000 series, the SY7000 and the SY5000
can be mounted on the same manifold. How to Order Manifold
Refer to pages 211 and
212 for dimensions of
Type 12/Top ported type.
SS5Y 5 M 12 F 1 05 U
/ 4 ) 0 1 6 2 *
Mixed Mounting Type
For the SY5000 series, it is possible to mount the SY3000 size valves on all
stations. However, the SY3000 manifold block width should be 12.5 mm.
(16 mm for ø8 or ø5/16" One-touch fitting)
Also, for the SY7000 series, it is possible to mount the SY5000 size valves on 1 P, E port entry
all stations. However, the SY3000 cannot be mounted onto the SY7000 series. U
1 U side (2 to 10 stations)
D
1 D side (2 to 10 stations)
B Both sides (2 to 24 stations)
/ Series 4 Connector type
1: For type “S”, supply/exhaust block
5 SY5000 Symbol Type Page
assembly with built-in silencer, choose U or
7 SY7000 F D-sub connector IP40 D for P port entry.
FW (25 pins) IP67
: Refer to page 171 for the EX600 and 6 on
) P 26 pins page 179 for the EX250.
PG Flat ribbon cable 20 pins 109
s7ITH,EADWIRE
PH 10 pins 6 SUP/EXH block assembly
Lead wire length J PC wiring — Nil Internal pilot
1 0.6 m G (20 pins) With power supply terminal S Internal pilot, Built-in silencer
2 1.5 m T Terminal block box 121 R External pilot
3 3m L1 34 cores
: For built-in silencer type, P and E ports are
L2 Lead wire 17 cores 131 available on U and D sides. 3/5(E) port is
L3 9 cores plugged. The silencer exhaust port is located
s7ITH$ SUBCONNECTOR)0 &LAT
on the opposite side of P, E port entry.
ribbon cable and PC wiring M Circular connector 141
(Example: When the P, E port entry is D
Connector entry direction EX500 Gateway side, the silencer exhaust port is U side.)
Decentralized
: Refer to page 171 for the EX600 and 6 on
1 Upward S: 157
System 2 page 179 for the EX250.
2 Lateral (128 Points)

: It is not necessary to select the items above for EX500 Gateway * Mounting
the valve with terminal block box or with circular Decentralized Nil Direct mounting
connector or the serial transmission type. S: Serial
System
159
transmission D DIN rail mounting (With DIN rail)
(64 Points) D0 DIN rail mounting (Without DIN rail)
0 Valve stations S6: EX600 171 For 3 Specify a longer rail than the
Symbol Stations Note D3 stations standard length.
S: EX250 179
02 2 stations Some connectors have a limitation [For the SS5Y5-M12, the SY5000
S:
···

···

EX260 187
on the number of stations. Refer valve is now at a mountable
···

···

to the pages shown in the table S4: EX126 195 For 24 length (manifold block length of
D24 stations 16 mm).]
24 24 stations “Connector type” for details. S3: EX120 203

: Refer to the pages shown in the table above
: Refer to page 227 to determine the L3 using
2 P, E port size (One-touch fittings) for details. “Calculation formula” for the DIN rail length.
(For the SY3000 and SY5000 mixed
Symbol SY5000 SY7000 Note
mounting type)
Nil ø10 ø12 Metric size
: Refer to page 271 for the fixation of DIN rail
N ø3/8" ø1/2" Inch size mounting type manifold.

How to Order Manifold Assembly

Example (SS5Y5-M12F1-:) 2-position double


2-position double SY3230-5U1-C6 (2 sets)
SY5230-5U1-C8 (3 sets)
Manifold base (5 stations)
SS5Y5-M12F1-05D

SS5Y5-M12F1-05D ··· 1 set (Type M12 5-station manifold base part no.)

SY5230-5U1-C8 ········ 3 sets (2-position double part no.)

SY3230-5U1-C6 ········ 2 sets (2-position double part no.)
ide The asterisk denotes the symbol for assembly.
Us Prefix it to the part numbers of the valve etc.
ns
a tio
St s4HEVALVEARRANGEMENTISNUMBEREDASTHESTSTATIONFROMTHE$SIDE
3
2 sUnder the manifold part number, state the valves to be mounted in order
1 from the 1st station as shown in the figure above. If the arrangement
ide
Ds
becomes complicated, specify on a manifold specification sheet.

225
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 13 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
/ 4 ) 0 1 6 2 * -    
Top ported

Plug-in
/ Series 2 Coil type  A, B port size
3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000
: Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type when a valve is continuously energized 01 1/8 SY5000
for long periods of time. 02 1/4 SY7000

: Be careful of the energizing time when the
4 Type of actuation

Metal Base
power saving circuit is selected. Refer to One-touch fitting (Metric)
1 Single page 268 for details. Symbol A, B port SY3000 SY5000 SY7000
2-position
2 Double C2 ø2 ) — —
3 Closed center
4 3-position Exhaust center
* Rated voltage C3 ø3.2 ) — —
C4 ø4 ) ) —

Plug-in
5 24 VDC
5 Pressure center C6 ø6 ) ) )
6 12 VDC
A
1 N.C./N.C. C8 ø8 — ) )
4-position
: Only 24 VDC is available for the serial
B
1 dual 3-port
N.O./N.O. C10 ø10 — — )
transmission type.
C
1 N.C./N.O. C12 ø12 — — )

1: Only rubber seal type is available for the


- Light/surge voltage suppressor One-touch fitting (Inch)

Manifold Exploded View


4-position dual 3-port valve.
Symbol A, B port SY3000 SY5000 SY7000

Type 50, 51, 52


and common specification
Surge voltage Common N1 ø1/8" ) — —
Symbol With light N3 ø5/32" ) ) —
suppressor specification
) Seal type Nil — — N7 ø1/4" ) ) )
0 Rubber seal N9 ø5/16" — ) )
R — Non-polar
1 Metal seal N11 ø3/8" — — )
U )
S — Positive
)
Z ) common

Connector Connecting Base


0 Pilot type NS — Negative  Thread type
Nil Internal pilot NZ ) common Nil Rc
R External pilot
: “Nil” is not available for the SI Unit manifold. F G

: Only “Z” and “NZ” types are available for with N NPT
the power saving circuit. Select a valve which T NPTF
is suited to the SI Unit output polarity or SI
1 Back pressure check valve Unit specification when the SI Unit is
: Only Nil is available for M5.
(Built-in valve type) selected.
Nil None Refer to the pages below for details.
EX500: P.158, 160 EX600: P.172
H  Type of mounting screw

Plug-in
Built-in
EX250: P.180 EX260: P.188

: Only rubber seal type. Manifold installed type EX126: P.196 EX120: P.204 Nil Round head combination screw
is available if the back pressure check valve
is required for a valve with metal seal. Refer
B Hexagon socket head cap screw

Manifold Exploded View


to page 256 for Ordering Example. However, K Round head combination screw (Falling-out-prevention type)
H Hexagon socket head cap screw (Falling-out-prevention type) Type 10, 11, 12
it is not recommended to use the built-in
valve type and the manifold installed type at
 Manual override
: For “K” and “H”, the valve body cover has a
the same time because it will reduce the flow. Nil: D: drop prevention construction to stop the

: The built-in valve type back pressure check Non-locking Push-turn mounting screws from falling out when the
valve is not available for the 3-position type push type locking valve is removed for maintenance etc.
and the SY7000. slotted
: When ordering a valve individually, the
type base gasket is not included.
6 Pilot valve option Since the base gasket is attached to the
manifold, please order the base gasket
Nil Standard (0.7 MPa)
Plug Assembly Part No.

separately if it is needed for maintenance


One-touch Fittings/

B Quick response type (0.7 MPa) service.


K
1 High pressure type (1.0 MPa) E: F: Refer to page 244 for part numbers of the
Push-turn Slide locking base gasket and mounting screw.

1: Only metal seal type is available for the locking type


high pressure type.
: “B” and “H” cannot be selected for the
lever individual SUP/EXH spacer assembly or
type interface regulator.
Manifold Options


: Refer to page 31 for with the safety slide
locking manual override.

Protective class
class  (Mark: )
226
Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Dimensions: Series SY5000 Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M12:- Stations D D side U side
B
(L5) L1

( Pitch of
SY5000 ) Manual override
32.8 21.1 P = 16
Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
78.9
(Slide locking manual override)
( Pitch of
SY3000 ) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
P = 12.5
2(B) port side : Yellow

(8)
LOCK

PE
3/5 B A B A B A B A B A

(5.5)

(35)
4A 4A
4A 4A 4A

113.4
26.5
E
FREE

X
1

(SY3000)

81.2
(SY3000)
2B 2B
(61.7)

(SY5000)
01 : 16.2
C:: 14.5

11
(SY5000)

56.4
P

47.3
39.5

2B 2B 2B

2.7
4.7

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø2
: ø6, ø1/4" : ø3.2, ø1/8"
: ø8, ø5/16" : ø4, ø5/32"
5.3 L4 : ø6, ø1/4"
(DIN rail mounting hole pitch: 12.5)
L3

(Station 1)--------- (Station n)


(SY5000)

(SY3000)
(91.3)

(87.4)
1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 4 A4 A4 A 3/5 E
4 A4 A

Calculation formula for dimensions with


D-sub connector <IP40>, Flat ribbon cable
(For DIN rail

and PC wiring
(7.5)

mounting)
(11.8)

L1 = 12.5 x n1 + 16 x n2 + 76.4
L2 = 12.5 x n1 + 16 x n2 + 48
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23
L4 = L3 – 10.5
: Refer to page 206 for dimensions of
L5 = (L3 – L1 + 6.1)/2 external pilot and elbow fittings.
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000

Calculation formula for dimensions with D-sub


connector <IP67>, Terminal block box, Lead wire,
Circular connector, EX500/600/250/260/126/120
serial transmission
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
L2 = 12.5 x n1 + 16 x n2 x 48
Coefficient a b c
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 D-sub connector <IP67> 90.5 — —
L4 = L3 – 10.5 Terminal block box or Serial transmission: EX126 149.3 — —
L5 = (L3 – L1)/2 Lead wire or Circular connector 97 — —
L6 = b x n3 + c EX500 Gateway Decentralized System 2 (128 Points) 88.7 — —
n1: Number of valve stations of the SY3000 EX500 Gateway Decentralized System (64 Points) 88.5 — —
n2: Number of valve stations of the SY5000 Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O Units or input block stations
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5

: Refer to pages 166 and 167 for dimensions of the EX600
Serial transmission: EX250 141.5 21 81.5
serial transmission with I/O Unit and page 177 for the
EX250 serial transmission with input block when L6, b Serial transmission: EX260 88.7 — —
and c are used for the calculation formula. Serial transmission: EX120 84.7 — —
227
Plug-in Connector Connecting Base Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Valve
Dimensions: Series SY7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M12:- Stations D
B
D side U side

Sub-plate
L1

(Light/surge voltage suppressor)


Manual override
One-touch fitting
[1(P), 3/5(E) port] (Pitch) (Pitch)
(
Push-turn locking slotted type:
)

Plug-in
33.9 26.1 P = 19 P = 19 42.2 Press, then rotate it.
Applicable tube O.D.: ø12, ø1/2"
4(A) port side: Blue (For rubber seal)
85.8 : Gray (For metal seal)
(Slide locking manual override) 2(B) port side: Yellow

PE
LOCK

3/5E B A B A B A B A B A

Metal Base
4A 4A 4A 4A 4A
21

128.8
FREE

SY5000: 95.7
SY7000: 96.7
(SY5000)
C:: 14.5
01: 16.2
1P

(SY5000)
77.1

(SY7000)

(SY7000)

Plug-in
X 2B 2B 2B
22.6

61.8
59.9

57.7

2B 2B
2.4

1/8
3.9

4 x M5 Mounting hole

Manifold Exploded View


1/4 [A(A), 2(B) port]

Type 50, 51, 52


[A(A), 2(B) port]
20.7 L2 1.5
(DIN rail mounting hole pitch: 12.5) One-touch fitting (For SY5000)
One-touch fitting (For SY7000) [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø6 , ø1/4" : ø6, ø1/4"
: ø8 , ø5/16" (Station 1) (Station n) : ø8, ø5/16"
: ø10, ø 3/8"
: ø12

Connector Connecting Base


(A, B port: ø12)
(SY7000)
(112.1)

(SY7000)

(SY5000)
(100.3)

(SY7000)

(98.2)
(SY5000)
88.8

83.8

1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

Plug-in
3/5 E 3/5 E
4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12

: Refer to page 207 for dimensions of external pilot and elbow fittings.

: Refer to the below pages for L1, L2, L3, L4 dimensions and other
Plug Assembly Part No.
One-touch Fittings/

dimensions that are not specified in each wiring specification.


Dimensions of Type 12/Top ported: P. 212
D-sub connector <IP40> : P. 102
D-sub connector <IP67> : P. 105
Flat ribbon cable : P. 108
Terminal block box : P. 120
Lead wire : P. 130
Manifold Options

Circular connector : P. 140


EX500 (128 points) : P. 150
EX500 (64 points) : P. 156
EX600 : P. 168, 169
EX250 : P. 178
EX260 : P. 186
EX126 : P. 194
EX120 : P. 202

228
Series SY3000/5000/7000 Type 10, 11, 12
Connector Connecting Base Manifold Exploded View
Manifold Exploded View Page 243 U side

D side

LOC
K
FRE
E


: The figures show the SY3000 series.

Wiring
D-sub Connector <IP40> D-sub Connector <IP67> Terminal Block Box Lead Wire
/Flat Ribbon Cable Page 231 Page 232 Page 233
Page 230

Circular Connector EX500 Gateway Decentralized EX500 Gateway Decentralized EX600


Page 234 System 2 (128 Points) System (64 Points) Page 237
Page 235 Page 236

EX250 EX260 EX126 EX120


Page 239 Page 240 Page 241 Page 242

229
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
D-sub Connector <IP40>/Flat Ribbon Cable Manifold exploded view

:
U side
Locking bracket
(For D-sub connector)

Sub-plate
LOC
Cover assembly K

Silencer cover assembly FRE


E
Port block assembly &
Refer to page 247.

Plug-in
Tension
bolt

Holding screw
D side

Metal Base
@ Clamp bracket assembly
It is mounted only for the DIN rail mounting type. Refer to pages 243 to 246
The holding screw of the clamping bracket is for details about common parts.
tightened at one point.
(Tightening torque of holding screw: 1.4 N·m)

Plug-in
Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
: SUP/EXH block assembly
Mounting
SY 3 0M 1 11 A 1 C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Note
Connector entry direction Symbol P, E port SY3000 SY5000 SY7000

Connector Connecting Base


C8 ø8 ) — — Side/Bottom/
1 Upward
SUP/EXH block assembly C10 ø10 — ) — Top ported
2 Lateral
11 D-sub connector <IP40> C12 ø12 — — ) Metric size
12 Flat ribbon cable (26 pins) N9 ø5/16" ) — — Side/Bottom/
13 Flat ribbon cable (20 pins) Pilot, Silencer/Piping type N11 ø3/8" — ) — Top ported
14 Flat ribbon cable (10 pins) Pilot type Built-in Piping N13 ø1/2" — — ) Inch size
Symbol Internal External silencer direction ø8
L8 ) — —
Downward elbow Upward elbow

15 PC wiring (20 pins) Side ported


PC wiring (20 pins) Nil ) — — L10 ø10 — ) — Metric size
35 with power supply terminal S ) — ) Side L12 ø12 — — )
R — ) — LN9 ø5/16" ) — —
Side ported
V ) — — LN11 ø3/8" — ) —

Plug-in
Inch size
RV — ) — Top LN13 ø1/2" — — )
VP ) — )
1 B8 ø8 ) — —
Side ported
B ) — — B10 ø10 — ) — Metric size

Manifold Exploded View


BS ) — ) Bottom B12 ø12 — — )
BR — ) — BN9 ø5/16" ) — —
Side ported Type 10, 11, 12

1: For silencer (supply side). E port is BN11 ø3/8" — ) — Inch size
plugged. BN13 ø1/2" — — )

: “B” for bottom ported can be selected 00
1 Plug ) ) ) P/E port entry on one
for the SY5000/7000 series. 00U
2 Plug ) ) ) side or Top ported

1: It can be selected only if no symbol or “S” or “V” or “B” is
SUP/EXH block assembly (D side) selected for the pilot and the piping.

2: “00U” is available only for the D-sub connector type and it
accessories and the number of accessories
has an inch size locking bracket.
SY3000 SY5000
Plug Assembly Part No.

Accessories
SY7000
One-touch Fittings/

& Tension bolt None


1 3 pcs.

1: Since the nuts are embedded in the SUP/EXH block.

@ Clamp bracket assembly


Series Part no.
Manifold Options

SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.

230
Series SY3000/5000/7000
Wiring
D-sub Connector <IP67> Manifold exploded view

:
U side

Locking &
bracket Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)

D side
Holding screw
Refer to pages 243 to 246
. Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
C8 ø8 ) — — Side/Bottom/
C10 ø10 — ) — Top ported
C12 ø12 — — ) Metric size
N9 ø5/16" ) — — Side/Bottom/
Pilot, Silencer/Piping type N11 ø3/8" — ) — Top ported
Pilot type Built-in Piping N13 ø1/2" — — ) Inch size
Symbol Internal External silencer direction
L8 ø8 ) — —
Downward elbow Upward elbow

Nil ) — — Side ported


L10 ø10 — ) — Metric size
S ) — ) Side L12 ø12 — — )
R — ) — LN9 ø5/16" ) — —
V ) — — Side ported
LN11 ø3/8" — ) — Inch size
RV — ) — Top LN13 ø1/2" — — )
VP ) — )
1 B8 ø8 ) — —
B ) — — Side ported
B10 ø10 — ) — Metric size
BS ) — ) Bottom B12 ø12 — — )
BR — ) — BN9 ø5/16" ) — —
Side ported

1: For silencer (supply side). E port is BN11 ø3/8" — ) — Inch size
plugged. BN13 ø1/2" — — )

: “B” for bottom ported can be selected 00
1 Plug ) ) ) P/E port entry on one
for the SY5000/7000 series. 00U
2 Plug ) ) ) side or Top ported

1: It can be selected only if no symbol or “S” or “V” or “B” is
SUP/EXH block assembly (D side) selected for the pilot and the piping.

2: “00U” has an inch size locking bracket.
accessories and the number of accessories
Accessories SY3000 SY5000
SY7000
& Tension bolt None
1 3 pcs.

1: Since the nuts are embedded in the SUP/EXH block.

@ D-sub connector block assembly <IP67> . Clamp bracket assembly


Part no. Connector direction Locking bracket Series Part no.
SY30M-14-9A1 Top SY3000 SY30M-15-1A
Metric size
SY30M-14-9A2 Side SY5000/7000 SY50M-15-1A
SY30M-14-9A1U Top
: Part number is for one assembly.
Inch size
SY30M-14-9A2U Side

231
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
Terminal Block Box Manifold exploded view
Mounting screw :
(Tightening torque: 0.8 N·m)
U side
@

Sub-plate
&

Plug-in
Tension
bolt

Mounting screw for


Holding D side

Metal Base
connecting parts
(Tightening torque: screw
0.8 N·m) Refer to pages 243 to 246
for details about common parts.
.
; Clamp bracket assembly

Plug-in
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Mounting screw
DIN rail holding screw (Tightening torque: 1.4 N·m)

Manifold Exploded View


(Tightening torque: 1.4 N·m)

Type 50, 51, 52


Manifold Parts No.
: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting

Connector Connecting Base


D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size

Plug-in
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —

Manifold Exploded View


LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) — Inch size Type 10, 11, 12
BR — ) —
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) —

: “B” for bottom ported can be selected Metric size
B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — —
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
SY3000 SY5000
Plug Assembly Part No.

Accessories
One-touch Fittings/

SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.

@ Terminal block box housing assembly


Manifold Options

VVQC1000 T0 1
; Clamp bracket assembly
. Clamp bracket assembly for terminal block box Series Part no.
SY3000 SY30M-15-1A
SY30M 15 4A SY5000/7000 SY50M-15-1A

: Part number is for one assembly.



: Part number is for one assembly.

232
Series SY3000/5000/7000
Wiring
Lead Wire Manifold exploded view

:
U side

@
&
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)
D side

Refer to pages 243 to 246 for


Holding screw details about common parts.
. Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —
LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) —

: “B” for bottom ported can be selected Metric size
B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — —
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
Accessories SY3000 SY5000
SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.

@ Lead wire connector block assembly


SY30M 14 4A
Number of cores Lead wire length [m]
1 34 1 0.6
2 17 2 1.5
3 9 3 3

. Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.


233
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
Circular Connector Manifold exploded view

:
U side

Sub-plate
@

&

Plug-in
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)
D side

Metal Base
Holding Refer to pages 243 to 246
screw
. Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is

Plug-in
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type

Connector Connecting Base


C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —
LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —

Plug-in
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) — Metric size

Manifold Exploded View



: “B” for bottom ported can be selected B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — — Type 10, 11, 12
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
Accessories SY3000 SY5000
SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.


Plug Assembly Part No.
One-touch Fittings/

@ Circular connector block assembly


SY30M 14 5A

: 26 pins
Manifold Options

. Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.

234
Series SY3000/5000/7000
Wiring
EX500: Gateway Decentralized System 2 (128 Points) Manifold exploded view

:
U side
@

&
Tension
bolt

D side

Holding screw Refer to pages 243 to 246


. Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —
LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) —

: “B” for bottom ported can be selected Metric size
B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — —
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
Accessories SY3000 SY5000
SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.

@ EX500 SI Unit
EX500 S103
. Clamp bracket assembly
Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.

235
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
EX500: Gateway Decentralized System (64 Points) Manifold exploded view

:
U side

Sub-plate
&

Plug-in
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)

D side

Metal Base
Holding screw Refer to pages 243 to 246
. Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is

Plug-in
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type

Connector Connecting Base


C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —
LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —

Plug-in
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) — Metric size

Manifold Exploded View



: “B” for bottom ported can be selected B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — — Type 10, 11, 12
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
Accessories SY3000 SY5000
SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.


Plug Assembly Part No.
One-touch Fittings/

@ EX500 SI Unit
EX500 Q 0 01
Output specifications
0 NPN (Positive common)
Manifold Options

1 PNP (Negative common)

. Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.

236
Series SY3000/5000/7000
Wiring
EX600 Manifold exploded view

Mounting screw :
(Tightening torque: 0.8 N·m) U side
@

.
&
Tension
= bolt

D side

Refer to pages 243 to 246


for details about common parts.
>

Holding screw

; Clamp bracket assembly


It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 ø8 ) — — Side/Bottom/
Built-in Piping
Symbol Internal External silencer direction C10 ø10 — ) — Top ported
C12 ø12 — — ) Metric size
Nil ) — —
ø5/16"
S ) — ) Side N9 ) — — Side/Bottom/
N11 ø3/8" — ) — Top ported
R — ) —
ø1/2" Inch size
V ) — — N13 — — )
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top
ø10
Side ported
VP ) — )
1 L10 — ) — Metric size
L12 ø12 — — )
B ) — —
ø5/16"
BS ) — ) Bottom LN9 ) — —
Side ported
LN11 ø3/8" — ) —
BR — ) —
ø1/2"
Inch size
LN13 — — )

1: For silencer (supply side). E port is plugged. B8 ø8 ) — —

: “B” for bottom ported can be selected for the Side ported
B10 ø10 — ) —
SY5000/7000 series. Metric size
B12 ø12 — — )
SUP/EXH block assembly (D side) BN9 ø5/16" ) — —
accessories and the number of accessories Side ported
BN11 ø3/8" — ) — Inch size
BN13 ø1/2" — — )
Accessories SY3000 SY5000
SY7000 P/E port entry on one
None
1 3 pcs.
00
1 Plug ) ) )
side or Top ported
& Tension bolt

1: Since the nuts are embedded in the SUP/EXH block.


1: It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.

@ Valve plate . EX600 SI Unit Version


EX600 ZMV2 EX600 S PR 1 Symbol
Nil
Description
When MJ, EN, EC or

: With mounting screws PN is selected


(2 pcs. of M4 x 6 and 2 pcs. of M3 x 8) Protocol A When PR or DN is selected
Symbol Description
PR PROFIBUS DP Output type
DN DeviceNet™ Symbol Description Condition
; Clamp bracket assembly MJ CC-Link 1 PNP (Negative common) Can be selected by all protocols.
EN EtherNet/IP™
1 2 NPN (Positive common) Can be selected by all protocols.
Series Part no.
EC EtherCAT®
1 PNP (Negative common) Can be selected in
SY3000 SY30M-15-1A PN PROFINET
1 3 EtherNet/IP (2 ports) the case of EN.
SY5000/7000 SY50M-15-1A
1: Cannot be communicated NPN (Positive common) Can be selected in

: Part number is for one assembly. with the EX600-HT1-:. 4 EtherNet/IP (2 ports) the case of EN.
237
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
= EX600 Digital Input Unit
EX600 DX P B

Sub-plate
Input type Number of inputs, open circuit detection, and connector
Symbol Description Symbol Number of inputs Open circuit detection Connector
P PNP B 8 No M12 connector (5 pins) 4 pcs.
N NPN C 8 No M8 connector (3 pins) 8 pcs.

Plug-in
C1 8 Yes M8 connector (3 pins) 8 pcs.
D 16 No M12 connector (5 pins) 8 pcs.
E 16 No D-sub connector (25 pins)
1
2
F 16 No Spring type terminal block (32 pins)
1
2

= EX600 Digital Output Unit


EX600 DY P B

Metal Base
Output type Number of outputs and connector
Symbol Description Symbol Number of outputs Connector
P PNP B 8 M12 connector (5 pins) 4 pcs.
N NPN E 16 D-sub connector (25 pins)
1
2
F 16 Spring type terminal block (32 pins)
1
2

Plug-in
= EX600 Digital Input/Output Unit
EX600 DM P E

Manifold Exploded View


Input/Output type Number of inputs/outputs and connector

Type 50, 51, 52


Symbol Description Symbol Number of inputs Number of outputs Connector
P PNP E 8 8 D-sub connector (25 pins)
1
2
N NPN F 8 8 Spring type terminal block (32 pins)
1
2

= EX600 Analog Input/Output Unit


EX600 AX A

Connector Connecting Base


Analog input/output Number of input channels and connector
Symbol Description Symbol Number of input channels Connector
AX Analog input A 2 channels M12 connector (5 pins) 2 pcs.
3
AY Analog output
3: Refer to
1 and
2 below for AY.

= EX600 Analog Input/Output Unit


EX600 AM B

Plug-in
Analog input/output Number of input/output channels and connector
Symbol Number of input channels Number of output channels Connector

Manifold Exploded View


M12 connector (5 pins)
B 2 channels 2 channels 4 pcs.
1
2 Type 10, 11, 12

B EX600 end plate


EX600 ED 2
Power connector Mounting
Symbol Connector Symbol Description
2 M12 (5 pins) Nil Without DIN rail mounting bracket
Plug Assembly Part No.
One-touch Fittings/

3 7/8 inch (5 pins) 3 With DIN rail mounting bracket

> Clamp bracket for EX600


EX600 ZMA3
Manifold Options

Enclosed parts
Round head screw with washer (M4 x 20) 1 pc.
P-tight screw (4 x 14) 2 pcs.


1: Cannot be communicated with the EX600-HT1-: (Old version of the Handheld Terminal).

2: Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2.

238
Series SY3000/5000/7000
Wiring
EX250 Manifold exploded view

:
U side

@
; &
Tension
= bolt

B
Holding screw D side

. Clamp bracket assembly Refer to pages 243 to 246


It is mounted only for the DIN rail for details about common parts.
mounting type.
The holding screws of the clamping
bracket is tightened at two points.
(Tightening torque of holding
screw: 1.4 N·m)
Manifold Parts No.
: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping
Symbol Internal External silencer direction C10 ø10 — ) — Top ported
C12 ø12 — — ) Metric size
Nil ) — —
ø5/16"
S ) — ) Side
N9 ) — — Side/Bottom/
N11 ø3/8" — ) — Top ported
R — ) —
ø1/2" Inch size
V ) — — N13 — — )
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top
ø10
Side ported
VP ) — )
1 L10 — ) — Metric size
L12 ø12 — — )
B ) — —
ø5/16"
BS ) — ) Bottom
LN9 ) — —
Side ported
LN11 ø3/8" — ) —
BR — ) —
ø1/2"
Inch size
LN13 — — )

1: For silencer (supply side). E port is plugged. B8 ø8 ) — —

: “B” for bottom ported can be selected for the Side ported
B10 ø10 — ) —
SY5000/7000 series. Metric size
B12 ø12 — — )
SUP/EXH block assembly (D side)
BN9 ø5/16" ) — —
accessories and the number of accessories ø3/8"
Side ported
BN11 — ) — Inch size
Accessories SY3000 SY5000
SY7000
BN13 ø1/2" — — )
P/E port entry on one
& Tension bolt None
1 3 pcs. 00
1 Plug ) ) )
side or Top ported

1: Since the nuts are embedded in the SUP/EXH block.


1: It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.
@ EX250 SI Unit
; Input block
EX250 S DN1
EX250 IE 1
Communication protocol
DeviceNet™ (Negative common) Block type
DN1
PR1 PROFIBUS DP (Negative common) 1 M12 connector, 2 inputs
MJ2 CC-Link (Positive common) 2 M12 connector, 4 inputs
AS3 AS-Interface (8 in/8 out, 31 slave modes, 2 isolated common type) (Negative common) 3 M8 connector, 4 inputs
AS5 AS-Interface (4 in/4 out, 31 slave modes, 2 isolated common type) (Negative common)
AS7 AS-Interface (8 in/8 out, 31 slave modes, 1 common type) (Negative common) = EX250 end plate assembly
AS9 AS-Interface (4 in/4 out, 31 slave modes, 1 common type) (Negative common)
CA1A
EN1
CANopen (Negative common)
EtherNet/IP™ (Negative common) EX250 EA1

: With mounting screws (2 pcs. of M3 x 10)

. Clamp bracket assembly


Series Part no. B Clamp bracket assembly for EX250 SI Unit
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A SY30M 15 3A

: Part number is for one assembly.


: Part number is for one assembly.
239
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
EX260 Manifold exploded view
: U side

Sub-plate
&
Tension
bolt

Plug-in
Holding screw
. Clamp bracket assembly
It is mounted only for the DIN rail mounting type. D side Refer to pages 243 to 246
The holding screws of the clamping bracket is tightened for details about common parts.

Metal Base
at two points. (Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly

Plug-in
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000

Manifold Exploded View


5 SY5000 P, E port size (One-touch fittings)

Type 50, 51, 52


7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type ø8
C8 ) — — Side/Bottom/
Pilot type Built-in Piping ø10 Top ported
Symbol Internal External silencer direction C10 — ) —
C12 ø12 — — ) Metric size
Nil ) — — N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) — N13 ø1/2" — — ) Inch size
V ) — — L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —

Connector Connecting Base


VP ) — )
1 Metric size
L12 ø12 — — )
B ) — — LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
SUP/EXH block assembly (D side) LN11 ø3/8" — ) —
BR — ) — Inch size
accessories and the number of accessories LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
SY3000 SY5000 plugged. Side ported
Accessories B10 ø10 — ) —
SY7000
: “B” for bottom ported can be selected ø12
Metric size
& Tension bolt None
1 3 pcs. B12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — —

1: Since the nuts are embedded in the Side ported


BN11 ø3/8" — ) —
SUP/EXH block. Inch size
BN13 ø1/2" — — )

Plug-in
P/E port entry on one
00
1 Plug ) )
side or Top ported )
@ EX260 SI Unit

1: It can be selected only if no symbol or “S” or “V” or “B” is
EX260 S PR1 selected for the pilot and the piping.

Manifold Exploded View


Type 10, 11, 12
Communication protocol
Number of Number of
Symbol Protocol SI Unit output polarity Communication
outputs connector Manifold symbol Symbol Protocol outputs SI Unit output polarity Communication
connector Manifold symbol
DN1 Source/PNP (Negative common) QAN EC1 Source/PNP (Negative common) DAN
32 Sink/NPN (Positive common) 32 Sink/NPN (Positive common)
DN2 DeviceNet™ M12
QA EC2 EtherCAT ® M12
DA
DN3 Source/PNP (Negative common) QBN EC3 Source/PNP (Negative common) DBN
16 Sink/NPN (Positive common) 16 Sink/NPN (Positive common)
DN4 QB EC4 DB
PR1 Source/PNP (Negative common) NAN PN1 Source/PNP (Negative common) FAN
32 Sink/NPN (Positive common) 32 Sink/NPN (Positive common)
PR2 M12
NA PN2 PROFINET M12
FA
Plug Assembly Part No.

PR3 Source/PNP (Negative common) NBN PN3 Source/PNP (Negative common) FBN
One-touch Fittings/

16 Sink/NPN (Positive common) 16 Sink/NPN (Positive common)


PR4 PROFIBUS DP NB PN4 FB
PR5 Source/PNP (Negative common) NCN EN1 Source/PNP (Negative common) EAN
32 Sink/NPN (Positive common) 32 Sink/NPN (Positive common)
PR6
1 NC EN2 EtherNet/IP™ EA
PR7 Source/PNP (Negative common) D-sub NDN EN3 Source/PNP (Negative common) M12
EBN
16 Sink/NPN (Positive common) 16 Sink/NPN (Positive common)
PR8 ND EN4 EB
MJ1 Source/PNP (Negative common) VAN
32 Sink/NPN (Positive common)
MJ2 CC-Link VA
Manifold Options

Source/PNP (Negative common) M12


MJ3 16 Sink/NPN (Positive common)
VBN
MJ4 VB

1: Enclosure is IP40 when the communication connector is D-sub.

. Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.


240
Series SY3000/5000/7000
Wiring
EX126 Manifold exploded view

:
U side
@

&
Tension
bolt
.

Mounting screw for D side


connecting parts
(Tightening torque: Refer to pages 243 to 246
Holding screw
0.8 N·m) for details about common parts.
; = Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


: SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type ø8
C8 ) — — Side/Bottom/
Pilot type Built-in Piping ø10 Top ported
Symbol Internal External silencer direction C10 — ) —
C12 ø12 — — ) Metric size
Nil ) — — N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) — N13 ø1/2" — — ) Inch size
V ) — — L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — — LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is B8 ø8 ) — —
plugged. Side ported
B10 ø10 — ) —

: “B” for bottom ported can be selected Metric size
B12 ø12 — — )
for the SY5000/7000 series. BN9 ø5/16" ) — —
Side ported
BN11 ø3/8" — ) — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — )
accessories and the number of accessories P/E port entry on one
00
1 Plug ) ) )
side or Top ported
Accessories SY3000 SY5000
SY7000
1: It can be selected only if no symbol or “S” or “V” or “B” is
& Tension bolt None
1 3 pcs. selected for the pilot and the piping.

1: Since the nuts are embedded in the SUP/EXH block.

@ EX126 SI Unit ; Clamp bracket assembly for EX126 SI Unit


EX126D SMJ1 SY30M 15 4A

: CC-Link (Positive common)


: Part number is for one assembly.

. Terminal block plate assembly = Clamp bracket assembly


Series Part no.
VVQC1000 74A 2 SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.
241
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000
Wiring

Valve
EX120 Manifold exploded view

:
U side

Sub-plate
&

Plug-in
Tension
bolt

D side

Metal Base
Holding screw Refer to pages 243 to 246
. Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screw of the clamping bracket is

Plug-in
tightened at one point.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
: SUP/EXH block assembly
Mounting
SY 3 0M 1 16A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series

: For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type

Connector Connecting Base


C8 ø8 ) — — Side/Bottom/
Pilot type Built-in Piping Top ported
Symbol Internal External silencer direction C10 ø10 — ) —
C12 ø12 — — ) Metric size
Nil ) — —
N9 ø5/16" ) — — Side/Bottom/
S ) — ) Side N11 ø3/8" — ) — Top ported
R — ) —
N13 ø1/2" — — ) Inch size
V ) — —
L8 ø8 ) — —
Downward elbow Upward elbow

RV — ) — Top Side ported


L10 ø10 — ) —
VP ) — )
1 Metric size
L12 ø12 — — )
B ) — —
LN9 ø5/16" ) — —
BS ) — ) Bottom Side ported
LN11 ø3/8" — ) —

Plug-in
BR — ) — Inch size
LN13 ø1/2" — — )

1: For silencer (supply side). E port is plugged. B8 ø8 ) — —

: “B” for bottom ported can be selected for the Side ported
B10 ø10 — ) — Metric size

Manifold Exploded View


SY5000/7000 series. B12 ø12 — — )
BN9 ø5/16" ) — —
Side ported Type 10, 11, 12
SUP/EXH block assembly (D side) BN11 ø3/8" — ) —
accessories and the number of accessories Inch size
BN13 ø1/2" — — )
P/E port entry on one
Accessories SY3000 SY5000
SY7000 00
1 Plug ) ) )
side or Top ported
& Tension bolt None
1 3 pcs.
1: It can be selected only if no symbol or “S” or “V” or “B” is

1: Since the nuts are embedded in the SUP/EXH block. selected for the pilot and the piping.

@ EX120 SI Unit
Plug Assembly Part No.
One-touch Fittings/

EX120 S DN1
Communication protocol
DN1 DeviceNet™ (Positive common)
CS1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common)
CS2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common)
Manifold Options

MJ1 CC-Link (Positive common)


CM1 CompoNet™ NPN (Positive common)
CM3 CompoNet™ PNP (Negative common)

. Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A

: Part number is for one assembly.


242
Series SY3000/5000/7000

Manifold Exploded View (Common Parts)


B Valve mounting screw SUP/EXH end block assembly
Caution (SY7000: 3 pcs.) (Includes &.)
Tightening torque Details Page 246 U side

M2: 0.16 N·m (SY3000)


M3: 0.8 N·m (SY5000/7000)


: Refer to page 244 for order numbers.
& Tension bolt

SUP blocking disk assembly


Refer to “Manifold Options” A-@
A-: ( Tightening torque: 0.8 N·m
SY3000: 2 pcs.
SY5000/7000: 3 pcs.
)
on page 255.
A-.
A-;

> DIN rail


It is mounted only for
the DIN rail mounting
type (with DIN rail.)

Manifold block
assembly
D side Details Page 245
EXH blocking disk assembly
= Refer to “Manifold Options”
Tie-rod on page 255. Holding screw 2 Clamp bracket assembly
(SY5000/7000: 3 pcs.) It is mounted only for the DIN
rail mounting type. (Tightening
torque of holding screw: 1.4 N·m)

: The figures show the SY3000 series.

Type 10, 11, 12: How to Increase Connector Type Manifold


1 Loosen the U-side tension bolt &, and remove <For SY3000>
the SUP/EXH end block assembly.

2 Screw in ; tie-rods for additional stations to


the = tie-rod of the manifold.
Screw them in until there is no gap
between the tie-rods. Manifold block assembly
1

: Base gasket
3 Connect the manifold block assembly and
SUP/EXH end block assembly to be added, and
tighten the tension bolt &.
@ Connector
gasket

; Tie-rod for
Tightening torque for tension bolt & (M3): 0.8 N·m additional
. Manifold stations
block gasket
Caution
1. Be sure to shut off the power and air supplies before
disassembly.
Furthermore, since air may remain inside the actuator, Gaskets are mounted.
piping and manifold, confirm that the air is completely
exhausted before performing any work.
1: Manifold block assembly
2. When disassembly and assembly are performed, air No. Description Quantity Note
leakage may result if the tightening of the tension bolt is
For base, connector
inadequate. :@. Gasket 3 and manifold block

Tie-rod for SY3000 2 pcs.


; additional stations SY5000 3 pcs.
SY7000 3 pcs.
Refer to page 244 for ordering single unit.

243
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
For SS5Y3-10/11/12, SS5Y5-(M)10/11/12, SS5Y7-(M)10/11/12
No. Description SY3000 SY5000 SY7000 Note
Base gasket Part numbers shown on the left are
A-: SY30M-9-1A SY50M-9-1A SY70M-9-1A

Sub-plate
Manifold block assembly

(for connector connecting base) for 10 valves. (10 pcs.)


A-@ Connector gasket SX3000-146-2 Supplied individually.
A-. Manifold block gasket SY30M-9-2 SY50M-9-2 SY70M-9-2 Supplied individually.
SY30M-49-2-A SV2000-55-2A-A SY70M-49-2-A
2 2 pcs. supplied (SY3000),

Plug-in
SY3000/5000/7000 3 pcs. supplied (SY5000/7000)
(10.5 mm pitch) (16 mm pitch) (19 mm pitch)
Tie-rod for
additional
stations
1

A-;
For mixed mounting of SY3000/5000: SV2000-55-2A-A
SY3000 A, B port size ø8, ø5/16" — 3 pcs. supplied.
(16 mm pitch)
For mixed mounting of SY3000/5000: SY50M-49-2-A
SY3000 except A, B port size ø8, ø5/16"
4 — 3 pcs. supplied.
(12.5 mm pitch)

2
:: Manifold stations (2 stations to 24
VVQC1000-TR-: SV2000-55-1-1-:-A SY70M-49-1-:-A stations) 2 pcs. supplied (SY3000),
SY3000/5000/7000

Metal Base
(10.5 mm pitch) (16 mm pitch) (19 mm pitch) 3 pcs. supplied (SY5000/7000)

3
4
SY50M-49-1-;-A

= Tie-rod (12.5 mm pitch)

SS5Y5-M ;: Manifold stations


Mixed mounting SV2000-55-1-;-A
5

Plug-in
type manifold — (2 stations to 24 stations)
(16 mm pitch) 3 pcs. supplied.
SY70M-49-1-;-A
2
SS5Y7-M


(19 mm pitch)

Round head combination screw


SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on the left are as follows.
Valve SY3000/5000:

Manifold Exploded View


(M2 x 32) (M3 x 32.5) (M3 x 36.5)
B mounting for 10 valves (20 pcs. included)

Type 50, 51, 52


screw Hexagon socket head cap screw
SY3000-222-1A SY5000-222-1A SY7000-222-1A SY7000:
(M2 x 32) (M3 x 32.5) (M3 x 36.5) for 10 valves (30 pcs. included)
> DIN rail VZ1000-11-1-: VZ1000-11-4-: Refer to page 249.
2 Clamp bracket assembly (for connector connecting base) SY30M-15-1A SY50M-15-1A Supplied individually.

1: The manifold of the SY3000 (SS5Y3-10/11/12) can be assembled by connecting the tie-rods for additional stations for the number of manifold stations.
However, the manifold of the SY5000 or SY7000 (SS5Y5/7-10/11/12 including mixed mounting) cannot be assembled by connecting the tie-rods for
additional stations for the number of manifold stations.

2: When mounting with the SY5000.

Connector Connecting Base

3: When mounting only the SY3000 (12.5 mm pitch except A, B port size ø8, ø5/16").

4: The port sizes except A, B port size ø8, ø5/16" are the following: ø2, ø3.2, ø4, ø6, ø1/8", ø5/32", ø1/4".

5: When mounting only the SY3000 (16 mm pitch A, B port size ø8, ø5/16").

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

244
Series SY3000/5000/7000

Manifold Parts No.


Manifold block assembly
SY 3 0M 2 1 D A C6
Series A, B port size (One-touch fittings)
3 SY3000 Symbol A, B port SY3000 SY5000 SY7000 Note Symbol A, B port SY3000 SY5000 SY7000 Note
5 SY5000 C2 ø2 ) — — L4 ø4 ) ) —
Side
7 SY7000 C3 ø3.2 ) — — Side/ L6 ø6 ) ) )
ported

Upward elbow
C4 ø4 ) ) — Bottom L8 ø8 —
1 ) ) Metric
Piping direction C6 ø6 ) ) ) ported L10 ø10 — — ) size
Side/Top ported C8 ø8 —
1 ) ) Metric L12 ø12 — — )
1 size
2 Bottom ported C10 ø10 — — ) LN3 ø5/32" ) — — Side
C12 ø12 — — ) LN7 ø1/4" ) ) — ported

: “2” for bottom ported can
N1 ø1/8" ) — — Side/ LN9 ø5/16" —
1 ) — Inch
be selected for the size
N3 ø5/32" ) ) — Bottom LN11 ø3/8" — — )
SY5000/7000 series.
N7 ø1/4" ) ) ) ported B4 ø4 ) ) —
N9 ø5/16" —
1 Inch B6 Side

Downward elbow
) ) ø6 ) ) )
size ported
N11 ø3/8" — — ) B8 ø8 —
1 ) )
Metric

1: Refer to mixed mounting type for ø8, ø5/16". B10 ø10 — — ) size
Single wiring B12 ø12 — — )
Marked with N BN3 ø5/32" ) — — Side
BN7 ø1/4" ) ) — ported
BN9 ø5/16" —
1 ) — Inch
Wiring type BN11 ø3/8" — — ) size
S Single wiring 00 Plug ) ) ) Top ported
D Double wiring

Manifold (All parts inside are included.)


block assembly
Mixed mounting of the SY3000/5000 : Base gasket
Manifold block assembly for mounting the SY3000 @ Connector
gasket ; Tie-rod for
SY50M 2 3 D A C6 additional
stations
Piping direction A, B port size (One-touch fittings)
3 Side/Top ported Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C2 L4
Downward elbow Upward elbow

ø2 ø4 Side ported
Side/Bottom Metric size
C3 ø3.2
ported L6 ø6
Wiring type C4 ø4 Metric size LN3 ø5/32" Side ported
Single wiring C6 ø6 LN7 ø1/4" Inch size
S
D Double wiring N1 ø1/8" Side/Bottom B4 ø4 Side ported
N3 ø5/32" ported B6 ø6 Metric size
N7 ø1/4" Inch size BN3 ø5/32" Side ported
BN7 ø1/4" Inch size
00 Plug Top ported

Gaskets are mounted.


Mixed mounting of the SY3000/5000
Manifold block assembly for mounting the SY3000 for ø8, ø5/16" . Manifold block gasket
(A manifold block assembly for mounting the SY3000 valves on the
SY5000 manifolds at A, B port size: ø8, ø5/16")
Manifold block assembly accessories and
SY50M 2 5 D A C8 the number of accessories
Piping direction A, B port size (One-touch fittings) Accessories SY3000 SY5000
SY7000
1
5 Side ported Symbol A, B port Note : Base gasket 1 pc.
6 Bottom ported C8 ø8 Side/Bottom ported Metric size @ Connector gasket 1 pc.
N9 ø5/16" Side/Bottom ported Inch size . Manifold block gasket 1 pc.
Wiring type L8 Upward ø8 Side ported Metric size ; Tie-rod assembly for additional stations 2 pcs. 3 pcs.
Single wiring LN9 elbow ø5/16" Side ported Inch size
1: Including mixed mounting type
S
D Double wiring B8 Downward ø8 Side ported Metric size
BN9 elbow ø5/16" Side ported Inch size

Mixed mounting of the SY5000/7000


Manifold block assembly for mounting the SY5000
SY70M 2 3 D A C10
Piping direction A, B port size (One-touch fittings)
3 Side/Bottom ported Symbol A, B port Note Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C6 L6 B6
Downward elbow

ø6 ø6 ø6
Upward elbow

Side/Bottom
C8 ø8
ported L8 ø8 Side ported B8 ø8 Side ported
Wiring type C10 ø10 Metric size L10 ø10 Metric size B10 ø10 Metric size
S Single wiring C12 ø12 L12 ø12 B12 ø12
D Double wiring N7 ø1/4" Side/Bottom Side ported Side ported
N9 ø5/16" ported LN11 ø3/8"
Inch size BN11 ø3/8"
Inch size
N11 ø3/8" Inch size 00 Plug Top ported
245
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
SUP/EXH end block assembly
SY 3 0M 3 1A C8

Sub-plate
Series Mounting
3 SY3000 Nil Direct mounting

Plug-in
5 SY5000 D0 DIN rail mounting (Without DIN rail)
7 SY7000
: For bottom ported, the symbol is nil.

Pilot, Silencer/Piping type


Pilot type Built-in Piping
Symbol
Internal External silencer direction
Nil ) — — SUP/EXH end block assembly

Metal Base
(Includes &.)
S ) — ) Side
R — ) —
V ) — —
RV — ) — Top
VP ) — )
1

Plug-in
B ) — —
BS ) — ) Bottom
BR — ) —
A-.

1: For silencer (supply side). E port is plugged.


& Tension bolt

: “B” for bottom ported can be selected for the


SY5000/7000 series. ( Tightening torque: 0.8 N·m
SY3000: 2 pcs.
SY5000/7000: 3 pcs.
)

Manifold Exploded View


Type 50, 51, 52
P, E port size (One-touch fittings)
Symbol P, E port SY3000 SY5000 SY7000 Note
C8 ø8 ) — —
Side/Bottom/Top ported
C10 ø10 — ) — Metric size
C12 ø12 — — ) SUP/EXH end block assembly accessories and the number of accessories
N9 ø5/16" ) — —
Side/Bottom/Top ported
Accessories SY3000 SY5000/7000
N11 ø3/8" — ) — Inch size & Tension bolt 2 pcs. 3 pcs.

Connector Connecting Base


N13 ø1/2" — — ) A-. Manifold block gasket 1 pc.
L8 ) — —
Downward elbow Upward elbow

ø8
Side ported Gasket is mounted.
L10 ø10 — ) — Metric size
L12 ø12 — — )
LN9 ø5/16" ) — —
Side ported
LN11 ø3/8" — ) — Inch size
LN13 ø1/2" — — )
B8 ø8 ) — —
Side ported
B10 ø10 — ) — Metric size
B12 ø12 — — )
BN9 ø5/16" ) — —

Plug-in
Side ported
BN11 ø3/8" — ) — Inch size
BN13 ø1/2" — — )
P/E port entry on one side
00
1 Plug ) ) )

Manifold Exploded View


or Top ported

1: It can be selected only if no symbol or “S” or “V” or “B” is selected for Type 10, 11, 12
the pilot and the piping. Plug Assembly Part No.
One-touch Fittings/
Manifold Options

246
Series SY3000/5000/7000

Manifold Parts No.


 Cover assembly/Silencer cover assembly/Port block assembly for SUP/EXH (end) block assembly
Mounting screw (M3)

Cover assembly
(Internal pilot) SY 3 0M 4 1A
Dent for positioning

Silencer cover assembly


(Internal pilot, Built-in silencer) SY 3 0M 5 1A

X, PE port

Port block assembly


(Side/Bottom ported, External pilot) SY 3 0M 6 1AR 00
X, PE port One-touch fitting type
Symbol X, PE port SY3000 SY5000 SY7000
ø4 ) ) —
Nil Metric size
ø6 — — )
ø5/32" ) ) —
P port U Inch size
ø1/4" — — )
E port

Port block assembly


(Top ported, Internal pilot, for silencer SY 3 0M 6 3AV C8
(supply side))
P port
E port
X, PE port
Port block assembly
(Top ported, Internal/External pilot) SY 3 0M 6 1A V C8
Series Pilot type
3 SY3000 Nil Internal pilot
5 SY5000 R External pilot

: Cover assembly, silencer cover assembly 7 SY7000


and port block assembly are included in
the SUP/EXH (end) block assembly, but P, E port size (One-touch fittings)
they need to be ordered for piping Symbol P, E port SY3000 SY5000 SY7000
direction change. C8 ø8 ) — —
C10 ø10 — ) —
Tightening torque for mounting screw
C12 ø12 — — )
SY3000/5000 (M3): 0.8 N·m
N9 ø5/16" ) — —
SY7000 (M4): 1.4 N·m N11 ø3/8" — ) —
N13 ø1/2" — — )
00
1 Plug ) ) )
Caution
1: Cannot be selected for the SY:0M-6-3AV-:
1. Be sure to shut off the power and air supplies before and SY:0M-6-1ARV-:.
disassembly.
Furthermore, since air may remain inside the actuator,
piping and manifold, confirm that the air is completely
exhausted before performing any work.
2. When disassembly and assembly are performed, air
leakage may result if the tightening of the cover and port
block assemblies are inadequate.

247
Series SY3000/5000/7000
One-touch Fittings and Plug Assembly/Part No.

Valve
Refer to “Changing One-touch Fittings” on page 272 for replacement method.

 One-touch fittings

Sub-plate
Port size SY3000 SY5000 SY7000
ø2 VVQ1000-50A-C2 — —
ø3.2 VVQ1000-50A-C3 — —
ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —

Plug-in
ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
ø10 — — VVQ2000-51A-C10
ø12 — — KQ2H12-17-X224
Metric size

ø4 SZ3000-73-1A-L4 SZ3000-74-1A-L4 —
ø6 SZ3000-73-1A-L6 SZ3000-74-1A-L6 SZ3000-83-1A-L6
ø8 Elbow type — SZ3000-74-1A-L8 SZ3000-83-1A-L8

Metal Base
ø10 — — SZ3000-83-1A-L10
ø12 — — KQ2L12-17N-X224
ø4 SZ3000-73-2A-L4 SZ3000-74-2A-L4 —
ø6 SZ3000-73-2A-L6 SZ3000-74-2A-L6 SZ3000-83-2A-L6
A, B port
1

Plug-in
ø8 Long elbow type — SZ3000-74-2A-L8 SZ3000-83-2A-L8
ø10 — — SZ3000-83-2A-L10
ø12 — — KQ2W12-17N-X224
ø1/8" VVQ1000-50A-N1 — —

Manifold Exploded View


ø5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —

Type 50, 51, 52


ø1/4" Straight type VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
ø5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
ø3/8" — — VVQ2000-51A-N11
Inch size

ø5/32" KJL03-95-X224 — —
ø1/4" KJL07-95-X224 KQ2L07-14-X224 —
Elbow type
ø5/16" — KQ2L09-14-X224 —
ø3/8" — — KQ2L11-14-X224

Connector Connecting Base


ø5/32" KJL03-95-X225 — —
ø1/4" KJL07-95-X225 KQ2L07-14-X225 —
Long elbow type
ø5/16" — KQ2L09-14-X225 —
ø3/8" — — KQ2L11-14-X225
ø8 VVQ1000-51A-C8 — —
ø10 Straight type — VVQ2000-51A-C10 —
ø12 — — VVQ4000-50B-C12
Metric size

ø8 SZ3000-74-1A-L8 — —

Plug-in
ø10 Elbow type — SZ3000-83-1A-L10 —
ø12 — KQ2L12-19N-X224

Manifold Exploded View


ø8 SZ3000-74-2A-L8 — —
ø10 Long elbow type — SZ3000-83-2A-L10 — Type 10, 11, 12
P, E port

ø12 — — KQ2W12-19N-X224
ø5/16" VVQ1000-51A-N9 — —
ø3/8" Straight type — VVQ2000-51A-N11 —
ø1/2" — — VVQ4000-50B-N13
Inch size

ø5/16" KQ2L09-14-X224 — —
ø3/8" Elbow type — KQ2L11-14-X224 —
Plug Assembly Part No.

ø1/2" — — KQ2L13-19N-X224
One-touch Fittings/

ø5/16" KQ2L09-14-X225 — —
ø3/8" Long elbow type — KQ2L11-14-X225 —
ø1/2" — — KQ2W13-19N-X224

1: A and B ports (ø8 and ø5/16") of the SY3000 and 5000 mixed mounting type are the same as those of the SY5000.

: Purchasing order is available in units of 10 pieces. Additionally, when performing the piping in the same orientation using the elbow type, please order
“elbow type” or “long elbow type” appropriately.
Manifold Options

 Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
P, E port VVQ1000-58A VVQ2000-58A SY9000-62-1A

: Purchasing order is available in units of 10 pieces.

248
Series SY3000/5000/7000
Manifold Options
 DIN rail dimensions/weight for the SY3000 Plug-in metal base and
the SY3000/5000 Plug-in connector connecting base
VZ1000-11-1-:

: After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box :.
L
8 (7.5)
5.5

(35)
(25)
Rail mounting hole pitch 12.5

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4

 DIN rail dimensions/weight for the SY5000/7000 Plug-in metal base and
the SY7000 Plug-in connector connecting base
VZ1000-11-4-:

: After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box :.
L
8
5.5

(35)
(25)

Rail mounting hole pitch 12.5 (10)

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3

249
Manifold Options Series SY3000/5000/7000
Caution
Tightening torque for mounting screw

Valve
M2: 0.16 N·m (SY3000)
Manifold Options
: Refer to pages 260, 262, 264 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Blanking plate assembly How to Order Blanking Plate Assembly


[With two mounting screws (3 pcs. for the SY7000)]
Used when valve additions are expected or for maintenance. A SY 3 0M 26 1 A

Sub-plate
structure is in place on the blanking plate to prevent the mounting
screws from sliding. Mounting Series Option for mounting
Mounting screw
Mounting screw (3 pcs.)
3 SY3000 With mounting screw
screw 5 SY5000
Nil (Round head combination screw)
(2 pcs.)

Plug-in
(2 pcs.)
7 SY7000 With mounting screw
B (Hexagon socket head cap screw)
(A) (B)
4 2 Base type
1 For plug-in connector connecting base
2 For plug-in metal base
5 1 3
(EA) (P) (EB)
SY30M-26-;A (-B) SY50M-26-;A (-B) SY70M-26-;A (-B) Circuit diagram

Metal Base
 Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting screws One-touch fitting
(3 pcs. for the SY7000)] Straight type SY 3 0M 38 1 A C6

Plug-in
When the same manifold is used for different pressures, an individual
SUP spacer assembly is used as a supply port for different pressures. One-touch fitting

: When selecting a One-touch fitting elbow type for a spacer assembly, Elbow type SY 3 0M 38 2 A L6
use it faced upward, since it interferes with A and B port piping in
Series
Type 50 and Type 10 manifolds.
3 SY3000

Manifold Exploded View


5 SY5000

Type 50, 51, 52


4(A)
2-position single valve 2(B) 7 SY7000
Individual SUP spacer
assembly Spacer type
Mounting 1(P') 38 Individual SUP spacer
screw 39 Individual EXH spacer
5(EA)
1(P)
3(EB) Individual SUP/EXH spacer assembly
Circuit diagram
2 Short elbow type

Connector Connecting Base


(Mounting example of a
2-position single valve) 3 Long elbow type
Base gasket Part numbers of mounting
: Select the long elbow type for a 3-position
screw (For repairs) valve when using Type 11 and Type 12
SY3000: SY3000-23-12A (2 pcs.) downward. However,
SY5000: SY5000-221-2A (2 pcs.) Type 11 of the SY3000 series for the mixed
SY7000: SY7000-221-2A (3 pcs.) mounting of connector connecting bases
cannot be used downward.

Port size (Metric/One-touch fittings)


Connector gasket
Symbol P, E port SY3000 SY5000 SY7000

Plug-in
L4 ø4 ) ) —
 Individual EXH spacer assembly L6 ø6 ) ) )
[With a connector gasket, a base gasket, and two mounting screws L8 ø8 — ) )

Manifold Exploded View


(3 pcs. for the SY7000)] L10 ø10 — — )
L12 ø12 — — ) Type 10, 11, 12
When valve exhaust affects other stations due to the circuit
configuration, this spacer assembly is used for individual valve exhaust. Port size (Inch/One-touch fittings)

: When selecting a One-touch fitting elbow type for a spacer assembly, Symbol P, E port SY3000 SY5000 SY7000
use it faced upward, since it interferes with A and B port piping in LN3 ø5/32" ) — —
Type 50 and Type 10 manifolds. LN7 ø1/4" ) ) —
LN9 ø5/16" — ) —
2-position single valve 4(A) LN11 ø3/8" — — )
2(B)
Individual EXH spacer
Plug Assembly Part No.

Port size (Metric/One-touch fittings)


One-touch Fittings/

assembly
3/5(E') Symbol P, E port SY3000 SY5000 SY7000
Mounting
screw C2 ø2 ) — —
5(EA)
1(P) C3 ø3 ) — —
3(EB) C4 ø4 ) ) —
Circuit diagram
C6 ø6 ) ) )
(Mounting example of a
2-position single valve) C8 ø8 — ) )
Manifold Options

Part numbers of mounting


C10 ø10 — — )
Base gasket screw (For repairs) C12 ø12 — — )
SY3000: SY3000-23-12A (2 pcs.)
SY5000: SY5000-221-2A (2 pcs.) Port size (Inch/One-touch fittings)
SY7000: SY7000-221-2A (3 pcs.) Symbol P, E port SY3000 SY5000 SY7000
N1 ø1/8" ) — —
N3 ø5/32" ) ) —
N7 ø1/4" ) ) )
Connector gasket N9 ø5/16" — ) )
N11 ø3/8" — — )
250
Series SY3000/5000/7000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options
: Refer to pages 260 to 265 for dimensions. M3: 0.8 N·m (SY5000/7000)

 SUP stop valve spacer assembly with residual


: For lever type
pressure release valve When locking the lever type
[With a connector gasket, a base gasket, and two mounting manual override, push the lever
down in the PUSH position with
screws (3 pcs. for the SY7000)]
your fingers until it stops, then
It is used to shut off the supply air to valves individually. turn the lever 90° clockwise.

: Cannot be selected when the elbows are facing upward in A (PUSH  LOCK)
and B ports in Type 10 manifolds, since they will interfere with Turning the lever without
the piping for the spacer assembly. pushing it down until it stops can
2-position single valve cause damage to the manual
SY 3 0M 50 1A E 4(A)
2(B)
override and other problems
such as air leakages.
To unlock the manual override,
Series Manual override Base gasket
turn the lever counterclockwise.
3 SY3000 Push-turn (LOCK  PUSH) Mounting screw
Connector gasket
5 SY5000 Nil locking EXH.
5(EA)
7 SY7000 slotted type 1(P) Part numbers of mounting
3(EB) screw (For repairs)
Push-turn SUP stop valve spacer assembly SY3000: SY30M-56-1A (2 pcs.)
E locking with residual pressure release valve SY5000: SY50M-56-1A (2 pcs.)
lever type Circuit diagram SY7000: SY70M-56-1A (3 pcs.)
(Mounting example of a 2-position single valve)
Valve mounting screw
[How to mount SUP stop valve spacer assembly with residual pressure release valve] Tightening torque:
Series SY3000: 0.16 N·m
Insert the SUP stop valve mounting screw from the side of the spacer assembly, Series SY5000/7000: 0.8 N·m
and mount it to the manifold. For Hexagon socket head cap screws
Tighten the SUP stop valve mounting screw to the specified tightening torque. Nominal wrench size:
Mount the valve and tighten the valve mounting screws to the specified Series SY3000: 1.5
tightening torque after mounting the SUP stop valve spacer assembly with Series SY5000/7000: 2.5
Valve
residual pressure exhaust valve.
SUP stop valve spacer

: Install the plate type nut to the spacer assembly as shown in the figure if it assembly with residual pressure
comes off. The SUP stop valve mounting screws can be tightened with a
hexagon wrench without removing the plate type nut. Plate type nut Hexagon wrench

: When the elbows are facing upward in A and B ports in Type 10 manifolds, Nominal wrench size:
Series SY3000: 1.3
they will interfere with the piping for the spacer assembly. Therefore, combine SUP stop valve mounting screw Series SY5000/7000: 2
the A and B ports with straight types or elbows facing downward. Tightening torque:

: This product is only for internal pilot specifications, as the external pilot air Series SY3000: 0.16 N·m
cannot be shut off. Series SY5000/7000: 0.8 N·m

Double check spacer assembly with residual pressure release valve (Side/Bottom ported) <Example>
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)] Double check spacer assembly with residual pressure release valve
It is used to hold the intermediate position of the cylinder for a long period of 3-position exhaust center valve
time. Use a 3-position exhaust center valve when the double check spacer
assembly with residual exhaust valve is used.
It can also be used for drop prevention at the cylinder stroke end when supply
residual pressure is released by using a 2-position single/double valve.
Operating pressure range: 0.1 to 1.0 MPa

: When the elbows are facing upward in A and B ports in Type 10 manifolds,
they will interfere with the piping for the spacer assembly. Therefore,
combine the A and B ports with straight types or elbows facing downward.
Series Part no. 4(A) 2(B) EXH.
5(EA)
SY3000 SY30M-60-1A 1(P)
3(EB)
SY5000 SY50M-60-1A Circuit diagram
SY7000 SY70M-60-1A (Intermediate stop: When 3-position exhaust center valve is mounted)
Mounting screw
Intermediate stop Drop prevention
3 31
Double check spacer assembly with residual pressure release valve
0 0
Applicable valve SY 5 40 1 SY 57 2 0 1 2-position single valve
7

Caution
s!IRLEAKAGEFROMTHEPIPEBETWEENTHEVALVEAND
cylinder or from the fittings will prevent the cylinder
from stopping for a long period of time. Check the
Base gasket leakage using neutral household detergent, such as
dish washing soap. Also, check the cylinder’s tube
gasket, piston packing and rod packing for air
leakage. 4(A) 2(B) EXH.
5(EA)
s#OMBININGWITH POSITIONCLOSEDCENTERORPRESSURE 1(P)
center valve will not work. 3(EB)
Circuit diagram
s)FTHEEXHAUSTOFTHEDOUBLECHECKSPACERISRESTRICTED
Connector gasket (Drop prevention: When 2-position single valve is mounted)
too much, the cylinder may not operate properly and
Part numbers of mounting screw (For repairs) may not stop intermediately.
SY3000: SY3000-23-27A (2 pcs.) s3ETTHECYLINDERLOADSOTHATTHECYLINDERPRESSUREWILL
SY5000: SY5000-221-4A (2 pcs.) be within two times that of the supply pressure.
SY7000: SY7000-221-4A (3 pcs.)
251
Manifold Options Series SY3000/5000/7000
Caution
Tightening torque for mounting screw

Valve
M2: 0.16 N·m (SY3000)
Manifold Options
: Refer to pages 261, 263, 265 for dimensions. M3: 0.8 N·m (SY5000/7000)

Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure).

Sub-plate
How to Order

SY 3 0M 05 P

Plug-in
Series Applicable valve
3
3 SY3000 Nil For single, double, and 4-position
3 For 3-position
Pressure gauge option
1
1: In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 No pressure gauge caution that the part numbers are different between the odd no. stations and the even no. stations
05 Pressure gauge with MPa display (For odd number station) to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) If using a connector connecting base M10/11/12 (mixed mounting type) or laminating two or more

Metal Base
types of spacer type manifold options for the neighboring stations, you can use only the model
N5 Pressure gauge with psi display (For odd number station)
2
without a pressure gauge (M1).
N6 Pressure gauge with psi display (For even number station)
2
2: As per the new Measurement Law, gauges with a psi display will only be sold to overseas
customers.

3: In the case of the SY3000 series, use caution that the part numbers will differ depending on the
SY 5 0M 00 P

Plug-in
one for single/double and 4- and 3-position due to the different length of solenoid valves. Also, if
you have selected a model with a pressure gauge, and if at least the one for 3-position is included
in the same manifold, use all the ones for 3-position to prevent the pressure gauges from
Series interfering with each other.
5 SY5000
7 SY7000 Regulating port

Manifold Exploded View


Part numbers of mounting screw (For repairs)
P 1(P) port

Type 50, 51, 52


Pressure gauge option SY3000: SY3000-23-12A (2 pcs.)
A1 4(A) port (P controlled type, A port regulation) SY5000: SY5000-221-6A (2 pcs.)
M1 No pressure gauge B1 2(B) port (P controlled type, B port regulation) SY7000: SY7000-221-6A (3 pcs.)
00 Pressure gauge with MPa display
N0 Pressure gauge with psi display
2

Mounting screw

Connector Connecting Base


Base gasket

Connector gasket

Plug-in
SY30M-05/N5-; SY30M-06/N6-; SY30M-M1-; SY50M-00/N0-; SY50M-M1-; SY70M-00/N0-; SY70M-M1-;
(With pressure gauge/ (With pressure gauge/ (Without pressure gauge) (With pressure gauge) (Without pressure gauge) (With pressure gauge) (Without pressure gauge)

Manifold Exploded View


For odd number station) For even number station)
Type 10, 11, 12
Specifications

Interface regulator model SY30M-;-;-; SY50M-;-; SY70M-;-;


1: 3-position closed center and pressure center, and 4-position
Applicable valve model
1 SY3; 03 ;(R) SY5; 03 ;(R) SY7; 03 ;(R) dual 3-port valves are only available for 1(P) port pressure
regulation.
Regulating port 1(P), 4(A), 2(B)

2: Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa
3: ( ): Denotes the values of SY30M-;-;-3.
Maximum operating pressure 1.0 MPa
: Always apply pressure from 1(P) port in the base for interface
Plug Assembly Part No.

Fluid Air regulator.


One-touch Fittings/

Ambient and fluid temperature –10 to 50nC (No freezing)


With pressure gauge 33(35)
3 75 93
Weight [g]
2
Without pressure gauge 27(29)
3 69 87

Symbol (A)4 2(B)


(A)4 2(B)
2(B)
Manifold Options

(A)4

(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)

1 4(A) port regulation 2(B) port regulation


1(P) port regulation (P) 1 1
(P controlled type, A port regulation) (P) (P controlled type, B port regulation) (P)

252
Series SY3000/5000/7000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Spacer Combinations and Screw List : M3: 0.8 N·m (SY5000/7000)

: SY3000 (M2) @ SY5000 (M3) . SY7000 (M3)


Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
:: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
@: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
.: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A :: SY3000-222-1A spacer assembly
@: SY5000-222-1A B with residual
B .: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
:: SY30M-56-2A
(2 pcs.) (2 pcs.) (3 pcs.)
C @: SY50M-56-2A Individual
.: SY70M-56-2A SUP (EXH)
C spacer
assembly

A Valve
<Round head combination screw>
:: SY3000-23-33A
@: SY5000-221-5A Double check
A .: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C spacer
assembly

A Valve
<Round head combination screw>
:: SY3000-23-32A
@: SY5000-221-3A
A Individual
.: SY7000-221-3A SUP (EXH)
SY3000- SY5000- SY7000-
B B spacer 23-32A — 221-3A — 221-3A —
assembly (2 pcs.) (2 pcs.) (3 pcs.)

C Individual
EXH (SUP)
C spacer
assembly

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
A Valve
<Round head combination screw> [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
:: SY3000-23-24A
@: SY5000-221-1A SUP stop valve
.: SY7000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A :: SY3000-222-1A pressure
@: SY5000-222-1A release valve
B .: SY7000-222-1A
Individual
C SUP (EXH) SY30M-56-4A SY50M-56-4A SY70M-56-4A
C spacer
(2 pcs.) (2 pcs.) (3 pcs.)
:: SY30M-56-4A
D assembly
@: SY50M-56-4A
.: SY70M-56-4A
Individual
EXH (SUP)
D spacer
assembly

: Mounting onto a manifold follows the order explained above.

: The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.

253
Manifold Options Series SY3000/5000/7000
Caution
Tightening torque for mounting screw

Valve
M2: 0.16 N·m (SY3000)
Spacer Combinations and Screw List @ M3: 0.8 N·m (SY5000/7000)

: SY3000 (M2) @ SY5000 (M3) . SY7000 (M3)


Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

Sub-plate
<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
:: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
@: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
.: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]

Plug-in
<Hexagon socket head cap screw> SUP stop valve
:: SY3000-222-1A spacer assembly
A
@: SY5000-222-1A B with residual
.: SY7000-222-1A pressure
B release valve SY30M-56-3A SY50M-56-3A SY70M-56-3A
:: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C @: SY50M-56-3A spacer

Metal Base
.: SY70M-56-3A C assembly with
residual pressure
release valve

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


23-24A 222-1A 221-1A 222-1A 221-1A 222-1A

Plug-in
<Round head combination screw> A Valve
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
:: SY3000-23-24A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
@: SY5000-221-1A
.: SY7000-221-1A SUP stop valve
spacer assembly
<Hexagon socket head cap screw>

Manifold Exploded View


:: SY3000-222-1A B with residual

Type 50, 51, 52


A @: SY5000-222-1A pressure
.: SY7000-222-1A release valve
B
Double check
:: SY30M-56-5A spacer assembly
C SY30M-56-5A SY50M-56-5A SY70M-56-5A
@: SY50M-56-5A C with residual
(2 pcs.) (2 pcs.) (3 pcs.)
.: SY70M-56-5A pressure release
D valve

Connector Connecting Base


Individual
D EXH (SUP)
spacer
assembly

A Valve
<Round head combination screw>
:: SY3000-23-32A

Plug-in
A @: SY5000-221-7A
.: SY7000-221-7A SY3000- SY5000- SY7000-
Interface
B
regulator
23-32A — 221-7A — 221-7A —

Manifold Exploded View


B (2 pcs.) (2 pcs.) (3 pcs.)
Type 10, 11, 12
C
Individual
C SUP (EXH)
spacer
assembly

: Mounting onto a manifold follows the order explained above.

: The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.
Plug Assembly Part No.

: When laminating an interface regulator with other options, only the combinations in the table above are possible.
One-touch Fittings/
Manifold Options

254
Series SY3000/5000/7000
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options
: Refer to pages 261, 263, 265 for dimensions. M3: 0.8 N·m (SY5000/7000)

Individual SUP block assembly Mounting screw How to Order Individual SUP/EXH Block Assembly
On the circuit of the plug-in connector One-touch fitting
connection base, an individual SUP Straight type SY 3 0M 78 1 A C6
block assembly can be used to supply
air to a series of valves if a separate One-touch fitting
air supply is required, or if addition air Elbow type SY 3 0M 78 2 A L6
is required for additional air flow. Series
Individual SUP block assembly 3 SY3000
occupies 1 station. 5 SY5000
Blocking disks also supplied (2 Block type
7 SY7000
78 Individual SUP block
pieces). Can be used to block both SUP blocking disk
sides of the number of stations being assembly 79 Individual EXH block
isolated for individual air supply (as
shown in example). <Example> Individual SUP/EXH block assembly

: Specify the mounting position of the D side U side
2 Short elbow type (Type 12)
block as well as the position where 3 Long elbow type (Type 11)
5(EA) 5(EA)
the SUP passage is to be blocked 1(P) X X 1(P)
: Long elbow type is for the
3(EB) 3(EB) SY5000/7000 only.
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 SUP blocking Port size (Metric/One-touch fittings)
disks to block SUP is attached to Symbol P, E port SY3000 SY5000 SY7000
individual SUP block.) L4 ø4 ) ) —

: Electrical wiring is connected to a L6 ø6 ) ) )
1(P)
number of stations in the individual (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) L8 ø8 — ) )
SUP block manifold. L10 ø10 — — )

: When used in M10/11/12 (mixed L12 ø12 — — )
mounting type), select the SY50M Port size (Inch/One-touch fittings)
type for SS5Y5 and the SY70M Symbol P, E port SY3000 SY5000 SY7000
type for SS5Y7. LN3 ø5/32" ) — —

: A structure to prevent screws falling LN7 ø1/4" ) ) —
out is in place on the individual SUP LN9 ø5/16" — ) —
block, making it much harder for the LN11 ø3/8" — — )
mounting screws to fall out.
Port size (Metric/One-touch fittings)
Individual EXH block assembly Mounting screw Symbol P, E port SY3000 SY5000 SY7000
On the circuit of the plug-in connector C2 ø2 ) — —
connection base, individual EXH C3 ø3 ) — —
block assembly can be used to C4 ø4 ) ) —
individually exhaust series of valves C6 ø6 ) ) )
when the exhaust from the valves C8 ø8 — ) )
would affect a number of other C10 ø10 — — )
stations. C12 ø12 — — )
Individual EXH block assembly
Port size (Inch/One-touch fittings)
occupies 1 station.
Symbol P, E port SY3000 SY5000 SY7000
Blocking disks also supplied (4 EXH blocking disk
assembly N1 ø1/8" ) — —
pieces). Can be used to block both
N3 ø5/32" ) ) —
sides of the number of stations being
<Example> N7 ø1/4" ) ) )
isolated for individual exhaust. (as
D side U side N9 ø5/16" — ) )
shown in example).
5(EA) X X 5(EA) N11 ø3/8" — — )

: Specify the mounting position of the 1(P) 1(P)
X X
block as well as the position where 3(EB) 3(EB)
the EXH passage is to be blocked
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 sets of EXH
blocking disks (4 pcs.) to block EXH
3(R)
is attached to individual EXH block.) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B)

: Electrical wiring is connected to a
number of stations in the individual
EXH block manifold.

: When used in M10/11/12 (mixed
mounting type), select the SY50M
type for SS5Y5 and the SY70M
type for SS5Y7.

: A structure to prevent screws falling
out is in place on the individual EXH
block, making it much harder for the
mounting screws to fall out.
255
Manifold Options Series SY3000/5000/7000

Valve
Manifold Options

SUP/EXH blocking disk assembly (for connector type manifold, Type 10, 11, 12)
[SUP blocking disk]

Sub-plate
By inserting the SUP blocking disk in the pressure supply passage of the
manifold valve, can provide two different high and low pressure in one
manifold.
[EXH blocking disk]

Plug-in
By inserting the EXH blocking disk in the exhaust passage of the manifold valve, SUP blocking EXH blocking
Series
can separate the exhaust from the valve so it does not affect the other valves. It disk assembly disk assembly
can also be used for the manifold for the positive pressure and vacuum mixed SY3000 SY30M-40-1A SY30M-40-2A
manifold. (2 pcs. are required to block FA/EB both sides of the EXH.) SY5000 SY50M-40-1A SY50M-40-1A
SY7000 SY70M-40-1A SY70M-40-1A

Label for blocking disk


If the blocking disk assembly is ordered using

Metal Base
Label to indicate and confirm on the manifold where the SUP/EXH the manifold specification sheet and ordered
blocking disk assemblies were inserted. (3 sheets each) at the same time as the manifold, the position
where the blocking disk assembly is inserted
SUP/EXH blocking SUP blocking EXH blocking will be labeled and shipped out.
disk label disk label disk label

Plug-in
Manifold Exploded View
Series Part no.

Type 50, 51, 52


SY3000
SY5000 SJ3000-155-1A
SY7000

Back pressure check valve assembly (Retrofit or pre-installed type)


For SY3000

Connector Connecting Base


It prevents cylinder malfunction caused by other valve exhaust entry. Insert
it into EA/EB port (valve mounting side) on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is used. EA port

When ordering assemblies incorporated with a manifold, refer to the Ordering Example below EB port
Back pressure check valve assembly
(when installed in all stations.)
2 pcs. in 1 set

When a check valve for back pressure prevention is desired and is to be
installed only in certain manifold stations, clearly indicate the part number
and specify the mounting position on the manifold specification sheet.
<Precautions> For SY5000/7000

Plug-in
1. The manifold installed type back pressure check valve assembly is
assembly parts with a check valve structure. However, since slight air EA port
leakage against the back pressure is allowed due to its structure, adverse

Manifold Exploded View


effects of the back pressure due to increase in exhaust resistance cannot EB port
be prevented if the manifold exhaust port and other exhaust ports are put Type 10, 11, 12
together for piping or if the piping diameter is narrowed. As a result, this
may cause the actuator and air operated equipment to malfunction. So, be
Mount the back pressure check valve
careful not to restrict the exhaust air. If the exhaust resistance becomes
assemblies on the EA and EB ports in
large, select a built-in valve type with rubber seal. the order shown in the figure above.
2. When the back pressure check valve assembly is mounted, please contact
SMC for valve flow rate characteristics. Series Part no.
SY3000 SY30M-24-1A
Ordering Example SY5000 SY50M-24-1A
Plug Assembly Part No.

SS5Y3-10F1-05B-C6·····1 set (Type 10 5-station manifold base part no.) SY7000 SY70M-24-1A
One-touch Fittings/


SY3201-5U1·················· 5 sets (2-position double part no.)

SY30M-24-1A················5 sets (Back pressure check valve assembly part no.)
The asterisk denotes the symbol for assembly.
Manifold Options

256
Series SY3000/5000/7000

Manifold Options
Dual flow fitting (for connector connecting base, Type 10, side ported)
This is a fitting for cylinder ports which enables simultaneous actuation and increase in flow rate of valves for 2 stations.

: When ordering assemblies incorporated into a manifold, refer to the Ordering Example below and specify on the manifold specification sheet.

How to Order Dual Flow Fitting

SY 3 0M 120 1A C8
Series A, B port size (One-touch fittings) Clip
3 SY3000 Symbol A, B port SY3000 SY5000
5 SY5000 C8 ø8 ) —
Metric size
C10 ø10 — )
Dual flow fitting
N9 Inch size
ø5/16" ) —
N11 ø3/8" — )
Ordering Example
SS5Y3-10F1-08B-CM

SY3100-5U1

SY30M-120-1A-C8
The asterisk denotes the symbol for assembly.

: Specifically for side porting for a connector
SY3000 SY5000 connecting base. Cannot be attached to bottom or
(22.8) (24.1)
top ported, or mixed mounting types that are metal or
connector connecting bases.

: When adding or changing clips, push them into the
very end of the manifold for each station. Also, make
13.6
11.1

sure to use the clip that was packed together, as the


32.1
26.3

clip and the fitting for one station differ among


products that can be used with the SY5000.

: Not available for the SY7000 series.

Silencer A
C
(One-touch fitting connection type)
This silencer can be mounted to the 3/5 Series Model Effective area A B C
øB
ød

(E: EXH) port of the manifold in one step. For SY3000 (ø8) AN15-C08 20 mm2 45 13 20
For SY5000 (ø10) AN20-C10 30 mm2 57.5 16.5 30.5
Body Sound absorbing material For SY7000 (ø12) AN30-C12 41 mm2 71.5 20 43.5

: Shipped together with the product. (Resin) (Resin sintered body)

Plug (White) Dimensions


These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Model A L øD Model A L øD
ports and P, E ports. ød (Metric size) ød (Inch size)
ød

2 KJP-02 8.2 17 3 1/8" KQ2P-01 16 31.5 5


3.2 KQ2P-23 16 31.5 5 5/32" KQ2P-03 16 32 6
øD

4 KQ2P-04 16 32 6 1/4" KQ2P-07 18 35 8.5


A 6 KQ2P-06 18 35 8 5/16" KQ2P-09 20.5 39 10
L 8 KQ2P-08 20.5 39 10 3/8" KQ2P-11 22 43 11.5
10 KQ2P-10 22 43 12 1/2" KQ2P-13 24 46 15
12 KQ2P-12 24 45.5 14

: Shipped together with the product.

257
Manifold Options Series SY3000/5000/7000

Valve
Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve.

Name plate (For connector connecting base)

SY3000: For SS5Y3-10 (Side ported)

Sub-plate
SY5000: For SS5Y5-10/11 (Side/Bottom ported)
SY7000: For SS5Y7-(M)10/11 (Side/Bottom ported)
SS5Y3-10
Name plate bracket assembly and name plate mounting instructions

Plug-in
Insert it into the groove on the name plate bracket onto which a SS5Y5- 10
11
SUP/EXH (end) block is mounted, as shown in Figure 2.

When ordering assemblies incorporated with a manifold, refer to the SS5Y7-(M) 10


11
Ordering Example below.

Mounting and Option


Mounting option
Symbol Printing DIN rail Direct

Metal Base
Yes No With Without Specified length mounting
AA ) — — — — )
A ) — ) — — —
A0 ) — — ) — —

Plug-in
A3 ) — — — For 3 stations —

A24 ) — — — For 24 stations —
BA — ) — — — )
B — ) ) — — —

Manifold Exploded View


B0 — ) — ) — —

Type 50, 51, 52


B3 — ) — — For 3 stations —

B24 — ) — — For 24 stations —
Ordering Example
: Name plates cannot be mounted onto Type 12 (Top ported) and Type
SS5Y3-10F1-05UR-C6AA······································· 1 set 10 (Side ported) mixed mounting types with top ported valves, nor onto

SY3200R-5U1·························································· 5 sets manifolds with optional laminated spacers.

: No name plate settings are available for the SY3000/SY5000 mixed
The asterisk denotes the symbol for assembly. mounting types. However, they are available for the SY5000/SY7000

Connector Connecting Base


mixed mounting types.

<SY3000> <SY5000/7000>
n = 1 to 3 n = 4 to 24 n = 1 to 3 n = 4 to 24
42.3

62.5

3 1 2 3 4 5 n: Number
of stations
1 3 1 2 3 4 5 n: Number
Pitch

Plug-in
Pitch of stations
10.5
P = 16 (SY5000)
P = 19 (SY7000)
Make sure to mount

Manifold Exploded View


Make sure to mount
in the right direction. (20°)
in the right direction. Type 10, 11, 12
SY5000: SY50M-86-;(N)
Tightening torque for mounting screw (M3): 0.8 N·m Tightening torque for mounting screw (M3): 0.8 N·m SY7000: SY70M-86-;(N)
SY30M-86-;(N) Name plate
Mounting screw Mounting screw
Name plate bracket Name plate Name plate bracket ; is the number of stations (1 to 24).
(M3) ;is the number of stations (1 to 24). (M3)
SY30M-85-1A
Name plate bracket assembly
(Supplied individually) SY50M-85-1A
Plug Assembly Part No.

(For SY5000 only) Align this line along


One-touch Fittings/

Align this line along


Name plate insertion hole the end of the Name plate bracket assembly the end of the
Port block 2-position valve. (Supplied individually) 2-position valve.

Valve end Valve end


SUP/EXH end block SUP/EXH
(External pilot type) end block
Manifold Options

SUP/EXH
SUP/EXH block
Figure 1 Figure 2
block
Figure 1 Figure 2
Insertion hole

258
Series SY3000/5000/7000

Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve.

If adding a name plate


If adding a name plate to a manifold in use, order a name plate bracket assembly, in addition to ordering a name plate.
Refer to the table below for the part number and the amount.

Name plate part number


Model SS5Y3-10 SS5Y5-10/11 SS5Y7-(M)10/11 Note
Name Printed SY30M-86-:N SY50M-86-:N SY70M-86-:N ;:Number of stations
plate No printing SY30M-86-: SY50M-86-: SY70M-86-: (1 to 24)

Name plate bracket assembly part number and number of items ordered
Model SS5Y3-10 SS5Y5-10/11
Name plate assembly part number SY30M-85-1A SY50M-85-1A
Internal pilot
2 pcs.
Manifold SUP/EXH U/D piping
block assembly Internal pilot
2 pcs.
Pilot type
double sided piping
2 pcs. Caution
External pilot
and 1 pc.
1 1. Be sure to shut off the power and air supplies before
U/D piping
P, E port entry mounting the name plate bracket assembly.
External pilot
Not required
1 Furthermore, since air may remain inside the
double sided piping
actuator, piping and manifold, confirm that the air is

1: If the manifold is an external pilot, an insertion slot for name plates is on the port block completely exhausted before performing any work.
of the SUP/EXH block assembly. Thus, a bracket assembly is no longer required on the 2. When disassembly and assembly are performed, air
port piping side. leakage may result if the tightening of the bracket

: Name plate bracket assembly is not required for the SY7000. mounting screws is inadequate.

259
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY3000
 Blanking plate assembly  Individual SUP/EXH spacer assembly
(Top/Bottom ported)

Sub-plate
B A B A B A B A B A B A 3/5E

92.6

92.6
92.7
14 A 14 A 4A 4A 4A 4A
89

89
101.2

101.2

Plug-in
111.6

111.6
1P
12 B 12 B 2B 2B 2B 2B

3.6

14
7.2

13.9
One-touch fitting

Metal Base
(SUP port, EXH port)
One-touch fitting Applicable tube O.D.: ø4, ø5/32"
1 P
(SUP port, EXH port) : ø6, ø1/4"
Applicable tube O.D.: ø4, ø5/32"
62.6

63.1

: ø6, ø1/4"
2B 2 B2 B 3/5 E

Plug-in
4 A4 A
4A

<Type 50, 51, 52> <Type 10, 12>

C6: 92.3
N7: 96.1
C6: 91.8
N7: 95.6
1 P

LN7: 63.8
L6 : 61.3
LN7: 63.3
L6 : 60.8

Manifold Exploded View


Type 50, 51, 52
2 B2 B 3/5 E

4 A4 A

<Type 51, 52> <Type 12>

Connector Connecting Base


 Individual SUP/EXH spacer assembly  SUP stop valve spacer assembly
(Side ported) with residual pressure release valve

B A B A B A B A B A B A B A B A
92.6

92.6

14 A 14 A 14 A 14 A
89

14 A 14 A 14 A 14 A
89
101.2

101.2

Plug-in
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

Manifold Exploded View


LOCK

PUSH
LOCK

PUSH
Type 10, 11, 12
(3.9)

(2)

(2)

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø2 Applicable tube O.D.: ø2
: ø3.2, ø1/8" : ø3.2, ø1/8"
: ø4, ø5/32" : ø4, ø5/32"
Plug Assembly Part No.

: ø6, ø1/4" : ø6, ø1/4"


One-touch Fittings/

1 P 1 P
1 P 1 P
78.1
77.6

77.6

78.1
(58.7)

(59.2)

2B 2 B2 B 3/5 E 2B B 3/5
39.5

2 B2 E
39

Manifold Options

4 A4 A
4 A4 A
4A 4A

<Type 50> <Type 10> <Type 50, 51, 52> <Type 10, 12>

: The dimensions within ( ) applies to the SY30-50-1AE.

260
Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY3000


Double check spacer assembly with residual Individual SUP/EXH block assembly
pressure release valve (Top ported)

B A B A B A B A B A 3/5E

92.6

92.6
14 A 14 A 14 A 14 A 4 A
89

101.2
112.8

112.8
SUP
1P
12 B 12 B 12 B 12 B 2 B

LOCK LOCK

3.6
PUSH PUSH

One-touch fitting
(SUP port, EXH port)
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"

LN7: 72.3
1 P

L6 : 69.8
83.6

1 P
84.1

2B 2 B2 B 3/5 E 2 B2 B 3/5 E

4 A4 A 4 A4 A
4A

<Type 50, 51> <Type 10> <Type 12>

Interface regulator Individual SUP/EXH block assembly


(Side ported)

B A B A B A B A B A B A B A B A B A
(100.7)

(100.7)

92.6
92.2

92.2
92.6
89

14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
(111.7)
103.2

103.2
(118.3)

(111.7)
109.8

109.8
(118.3)

SUP

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B
Max. 14

Max. 14

05
SY30M- N5 -;-;
06
SY30M- N6 -;-; One-touch fitting
SY30M-M1-;-; (SUP port, EXH port)
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P
: ø6, ø1/4"
1 P 1 P
77.6
76.9

78.1
77.4
62.1

62.6

2 B2 B 3/5 E
48

2B 2 B2 B2 B2 B 3/5 E
39.9

40.4

4 A4 A
4 A4 A4 A4 A
4A

<Type 50, 51, 52> <Type 10, 12> <Type 10>


: The dimensions within ( ) applies to the SY30M-;-;-3.

261
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY5000
 Blanking plate assembly  Individual SUP/EXH spacer assembly
(Top/Bottom ported)

Sub-plate
BA BA BA BA BA BA 3/5
14 A 14 A 4A 4A 4A 4A

106.2
113.4

113.4

116.7
116.6

Plug-in
126.5
126.4
E
81.6

142.5
142.4
1

P
12 B 12 B 2B 2B 2B 2B

12.6

5.5

18.2
18.2

Metal Base
One-touch fitting One-touch fitting
73.2

1 P
68.6

2B
2 B2 B (SUP port, EXH port) (SUP port, EXH port)
3/5 E
Applicable tube O.D.: ø4 Applicable tube O.D.: ø4,
: ø6, ø1/4" : ø6, ø1/4"

Plug-in
4A
4 A4 A
: ø8, ø5/16" : ø8, ø5/16"

<Type 50, 51, 52> <Type 10, 11, 12>

Manifold Exploded View


(108.8)
(104.2)

Type 50, 51, 52


(76.8)
(72.2)
1 P
2 B2 B

3/5 E

4 A4 A

<Type 51, 52> <Type 11, 12>

Connector Connecting Base


 Individual SUP/EXH spacer assembly  SUP stop valve spacer assembly
(Side ported) with residual pressure release valve

Plug-in
BA BA BA BA B A B A B A B A
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
106.2

106.2
113.4

113.4
127.7

127.9

Manifold Exploded View


12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B
Type 10, 11, 12

LOCK LOCK
(6.1)

PUSH PUSH
(3)

(3)

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø4, ø5/32"
Plug Assembly Part No.

: ø6, ø1/4" : ø6, ø1/4"


One-touch Fittings/

: ø8, ø5/16" : ø8, ø5/16"


90.7
86.1

(78.2)
(73.6)

1 P
2 B2 B
2B
3/5 E
1 P
1 P 4A
90.7
86.1

4 A4 A
1 P
2 B2 B
Manifold Options

2B
51.6
47

3/5 E <Type 50, 51, 52> <Type 10, 11, 12>


4A
4 A4 A

: The dimensions within ( ) applies to the SY50-50-1AE.

<Type 50> <Type 10>

262
Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY5000


Double check spacer assembly with residual Individual SUP/EXH block Individual SUP/EXH block
pressure release valve assembly (Top ported) assembly (Side ported)

B A B A B A B A
14 A 14 A 14 A 14 A B A 3/5 B A
106.2

4 A

113.4
14 A

113.4
113.4
138.6

138.7

126.7
E
1

12 B 12 B 12 B 12 B SUP SUP
P
2 B 12 B

LOCK LOCK
PUSH PUSH

5.7
One-touch fitting
(SUP port, EXH port) One-touch fitting
Applicable tube O.D.: ø4 (SUP port, EXH port)
: ø6, ø1/4" Applicable tube O.D.: ø4, ø5/32"
101.2

: ø8, ø5/16" : ø6, ø1/4"


96.6

1 P : ø8, ø5/16"
2 B2 B
2B

3/5 E P
4A
4 A4 A 1 1

(88.9)
1 P 1 P
<Type 50, 51> <Type 10, 11>

63.7
2 B2 B 2 B2 B

3/5 E 3/5 E

4 A4 A 4 A4 A

<Type 12> <Type 10>

Interface regulator Individual SUP/EXH block assembly


(Bottom ported)

BA BA BA BA BA BA
14 A 14 A 14 A 14 A B A
106.2

14 A 14 A
113.4

14 A
113.4
127.5

127.6
145.5

145.6

142.7

12 B 12 B 12 B 12 B 12 B 12 B SUP

12 B
21.7
Max. 21

Max. 21

00 One-touch fitting
SY50M- N0 -;
(SUP port, EXH port)
SY50M-M1-; Applicable tube O.D.: ø4,
: ø6, ø1/4"
P : ø8, ø5/16"
96.2
92.4
91.6

1 P
87.8

(38.5)
74.5

79.1

2 B2 B2 B
54.6

2B
50

3/5 E
4A
4 A4 A4 A

<Type 50, 51, 52> <Type 10, 11, 12> <Type 11>

263
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY7000
Blanking plate assembly Individual SUP/EXH spacer assembly
(Top/Bottom ported)

Sub-plate
B A B A B A B A B A B A
14 A 14 A 4A 4A 4A 4A

116.7

116.7
128.8

Plug-in
128.8

133.2
145.1

145.1
92.1

164.1

164.1
12 B 12 B 2B 2B 2B 2B

19.2

38.2

21.7
7.1

Metal Base
One-touch fitting One-touch fitting
(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø6, ø3/8" Applicable tube O.D.: ø6, ø3/8"
80.1
78.3

1 P
2B 2 B2 B : ø8 : ø8

Plug-in
3/5 E : ø10 : ø10
4 A4 A
4A : ø12 : ø12

<Type 50, 51, 52> <Type 10, 11, 12>

Manifold Exploded View


Type 50, 51, 52
(121.1)
(119.3)

(83.2)
(81.4)
1 P
2 B2 B

3/5 E
4 A4 A

<Type 51, 52> <Type 11, 12>

Connector Connecting Base


Individual SUP/EXH spacer assembly SUP stop valve spacer assembly with residual
(Side ported) pressure release valve

B A B A B A B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
116.7

116.7

Plug-in
(126.3)

(For ø12)

128.8
(138.2)

148.7

148.7

Manifold Exploded View


(9.6)

Type 10, 11, 12


12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

PUSH LOCK PUSH LOCK


(For ø12)
(21.5)

(2)

(2)

Plug Assembly Part No.

One-touch fitting One-touch fitting


One-touch Fittings/

(SUP port, EXH port) (SUP port, EXH port)


100.9
99.1

Applicable tube O.D.: ø6, ø1/4" Applicable tube O.D.: ø6, ø1/4"
(86.8)
(85)

1 P
: ø8, ø5/16" : ø8, ø5/16" 2B 2 B2 B
: ø10, ø3/8" : ø10, ø3/8" 3/5 E
: ø12 : ø12 4A
4 A4 A
Manifold Options

<Type 50, 51, 52> <Type 10, 11, 12>


1 P
100.9
99.1


: The dimensions within ( ) applies to the SY70-50-1AE.
1 P
2B 2 B2 B
56.8
55

3/5 E
4 A4 A
4A

<Type 50> <Type 10>


264
Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY7000


Double check spacer assembly with residual Individual SUP/EXH block Individual SUP/EXH block
pressure release valve assembly (Top ported) assembly (Side ported)

B A B A B A B A B A B A
14 A 14 A 14 A 14 A 4A 14 A
116.7

(126.3)

(For ø12)
128.8

128.8

(138.2)
145.1
167.1

167.1
SUP SUP

12 B 12 B 12 B 12 B 2B 12 B

7.1
PUSH LOCK PUSH LOCK

One-touch fitting
(SUP port, EXH port)
One-touch fitting
Applicable tube O.D.: ø6, ø3/8"
: ø8 (SUP port, EXH port)
: ø10 Applicable tube O.D.: ø6, ø3/8"
: ø12 : ø8
: ø10
: ø12
113.1

114.9

P
1 P
2B 2 B2 B
1 1

(95.2)
3/5 E
4 A4 A 1 P 1 P
4A

68.8
2 B2 B 2 B2 B

3/5 E 3/5 E
4 A4 A 4 A4 A
<Type 50, 51> <Type 10, 11>

<Type 12> <Type 10>

Interface regulator Individual SUP/EXH block assembly


(Bottom ported)

B A
B A B A B A B A B A B A
14 A
14 A 14 A 14 A 14 A 14 A 14 A
116.7

128.8
143.8

143.8

154.9

164.1
161.8

161.8

SUP

12 B
12 B 12 B 12 B 12 B 12 B 12 B
Max. 21

Max. 21

00
SY70M- N0 -: P

SY70M-M1-:

1 P
(42.4)

3/5 E

One-touch fitting
(SUP port, EXH port)
101.3

103.1
96.1
94.3

<Type 11> Applicable tube O.D.: ø8, ø3/8"


82.8

1 P
81

2B 2 B2 B2 B : ø10
58.3
56.5

3/5 E
: ø12
4 A4 A4 A
4A

<Type 50, 51, 52> <Type 10, 11, 12>

265
Series SY3000/5000/7000
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Environment Manual Override

Warning Warning
1. Do not use valves in atmospheres of corrosive gases, chemi-  Push-turn locking lever type [Type E]
cals, sea water, water, water vapor, or where there is direct Push down on the manual override by finger until it stops, and
contact with any of these. then turn it 60° clockwise. The manual override is then locked.
2. Products compliant with IP67 enclosures (based on IEC60529) To release it, turn it counterclockwise. If it is not turned, it can
are protected against dust and water, however, these products be operated the same way as the non-locking type.
cannot be used in water. If using in an environment that is
exposed to water and dust splashes, take measures such as
Locked
using a protective cover.
position
3. When using built-in silencer type manifold with an IP67 enclo-
sure, keep the exhaust port of the silencer from coming in
direct contact with water or other liquids.
4. The metal seal valve is provided with a hole to discharge the OFF
pilot EXH. When using in atmospheres containing water and
dust, mount it horizontally. ON
B

Valve Mounting
Carefully check the manual override
Caution projection amount.

(3.7)
Mount it so that there is no Max. (at OFF): 3.7 mm
Series Thread size Tightening torque
slippage or deformation in SY3000 M2 0.16 N·m
gaskets, and tighten with SY5000/7000 M3 0.8 N·m
the tightening torque as
shown below.

Manual Override Caution


Do not apply excessive torque when turning the manual
Warning override. [0.1 N·m]
When locking the manual override, be sure to push it down
Regardless of an electric signal for the valve, the manual override
before turning. Turning without first pushing it down can cause
is used for switching the main valve. Connected actuator is
damage to the manual override and other trouble such as air
started by manual operation. Use the manual override after
leakage etc.
confirming that there is no danger.
 Slide locking type (Manual)
 Non-locking push type
It is locked by sliding the manual override all the way in the
Push down on the manual
direction indicated by the arrow (ON side) with a small flat
override button until it stops.
head screwdriver or with your fingers. Slide it in the direction
indicated by the arrow (OFF side) to release it.

OFF Locked
position
ON

 Push-turn locking slotted type [Type D]


OFF
Push down on the manual override with a small flat head
screwdriver until it stops, and then turn it 90n clockwise. The B
manual override is then locked. To release it, turn it counter- ON
clockwise. A
If it is not turned, it can be operated the same way as the
non-locking type.
Locked
position

PUSH
TURN

B A

266
Series SY3000/5000/7000
Specific Product Precautions 2
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Back Pressure Check Valve Valve and Manifold Combination


The SY series plug-in valve has the common configuration of the
Caution valve mounting surface between base mounted type (SY 57 :0:)
3
3

"There are two types of back pressure check valves; the one and top ported type (SY 7 :3:), therefore, it can be mounted to
5

which is built into a valve (with rubber seal type only) and the all manifolds of the side ported type (Type 50 and Type 10), the
one which is built in on the manifold side with connector bottom ported type (Type 51 and Type 11) and the top ported type
connection. Both of them have a check valve built-in to prevent (Type 52 and Type 12). For example, air output can be obtained
back pressure. For this reason, use caution that the valves with from both sides of the A and B ports of the manifold and the
external pilot specification cannot be pressurized from exhaust valve by mounting a top ported valve to a side ported or bottom
port [3/5(E)]. As compared with the types which do not integrate ported manifold, and a pressure switch can be connected to the
the back pressure check valve, C value of the flow rate output port on one side. However, when selecting valves and
characteristics goes down. Please contact SMC for details. manifolds, note that when a base mounted valve is mounted to a
"The manifold installed type back pressure check valve top ported manifold, there will be no output from the A and B port.
assembly is assembly parts with a check valve structure.
However, since slight air leakage against the back pressure is
allowed due to its structure, adverse effects of the back
pressure due to increase in exhaust resistance cannot be
prevented if the manifold exhaust port and other exhaust ports
are put together for piping or if the piping diameter is narrowed.
As a result, this may cause the actuator and air operated
equipment to malfunction. So, be careful not to restrict the
exhaust air. If the exhaust resistance becomes large, select a
built-in valve type with rubber seal.
"Do not switch valves when A or B port is open to the
atmosphere, or while the actuators and air operated equipment
are in operation. For built-in valve type with rubber seal, the
back pressure prevention seal may be peeled off, which may
cause air leakage or malfunctions. Use caution especially when
performing a trial operation or maintenance work.

Exhaust Throttle

Caution
The SY series pilot valve and main valve share a common
exhaust inside the valve. Therefore, do not block the exhaust port
when arranging the piping.

Used as a 3-Port Valve

Caution
 In case of using a 5-port valve as a 3-port valve
The SY3000/5000/7000 series can be used as normally closed
(N.C.) or normally open (N.O.) 3-port port valves by closing
one of the cylinder ports 4(A) or 2(B) with a plug. However,
they should be used with the exhaust ports kept open. They
are convenient at times when a double solenoid type 3-port
valve is required.

Plug position B port A port


Type of actuation N.C. N.O.
(A)4 2(B) (A)4 2(B)
Number of solenoids

Single
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

(A)4 2(B) (A)4 2(B)


Double
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

267
Series SY3000/5000/7000
Specific Product Precautions 3
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Light/Surge Voltage Suppressor

Caution
 Polar type  With power saving circuit
Positive common Negative common Power consumption is decreased by approx. 1/3 by reducing
Single solenoid Single solenoid the wattage required to hold the valve in an energized state.
(Effective energizing time is over 67 ms at 24 VDC.)
Light/surge voltage suppressor (:Z) Light/surge voltage suppressor (:NZ)
: Be careful of the energizing time, as quick response and high pressure
Polarity protection diode Polarity protection diode types will become operational when the energizing time is over 40 ms.
COM COM
(+) (−) <Standard> <High pressure>
LED Electric circuit diagram
Coil

Coil
LED
(With power saving circuit) Polarity protection diode
[SOL.a] [SOL.a] (Orange) In the case of single solenoid
(−) (+)
(+) (+)

Timer circuit
Diode

Diode
Surge voltage suppressor (:S) Surge voltage suppressor (:NS)

PWM circuit
Coil

Coil
LED
Polarity protection diode Polarity protection diode
COM COM i2 i1
(+) (−) (−)
(−)
Coil
Coil

[SOL.a] [SOL.a] i1: Starting current, i2: Holding current


(−) (+) Polarity protection diode
Not available for the 12 VDC
Positive common Negative common specification.

Double solenoid, Double solenoid, The above circuit reduces the power consumption for holding in
3-position, 4-position 3-position, 4-position order to save energy. Refer to the electrical power waveform as
Light/surge voltage suppressor (:Z) Light/surge voltage suppressor (:NZ) shown below.
[SOL.b] [SOL.b] <Electrical power waveform with power saving circuit>
(−) (+) LED
LED
Coil

Coil

(Green) (Green) Applied voltage


COM COM 24 V
(+) (−)
LED
Coil

Coil

LED (Orange)
[SOL.a] (Orange) [SOL.a] 0V
(−) (+)
Polarity protection diode Polarity protection diode

Surge voltage suppressor (:S) Surge voltage suppressor (:NS)


Standard
[SOL.b] [SOL.b] 0.35 (0.9) W
(−) (+) With power saving
circuit
Coil

Coil

0.1 (0.4) W
COM COM
(+) (−)
0W
Coil

Coil

67 ms (40 ms)
[SOL.a] [SOL.a]
(−) (+) The values in ( ) are for the high pressure and quick response types.
Polarity protection diode Polarity protection diode

s4HE6$#SPECIFICATIONWITHPOWERSAVINGCIRCUITSTANDARD
 Non-polar type specification) does not have the polarity protection diode. Do
With surge voltage suppressor (:R) not make a mistake with the polarity.
Single solenoid Double solenoid s 3INCE THE VOLTAGE WILL DROP BY APPROX  6 DUE TO THE
SOL.b transistor, pay attention to the allowable voltage fluctuation.
(−,+) (For details, refer to the solenoid specifications of each type
COM
Coil

(+,−) Varistor of valve.)


COM
Coil

Varistor
(+,−)
SOL.a Residual voltage of the surge voltage suppressor
Coil

(−,+) Varistor
SOL.a
: If a varistor or diode surge voltage suppressor is used, there is
(−,+) some residual voltage to the protection element and rated
voltage. Therefore, refer to the below table and pay attention to
With light/surge voltage suppressor (:U) the surge voltage protection on the controller side. Also, since
the response time does change, refer to the valve
Single solenoid Double solenoid
specifications on page 14.
SOL.b LED
(−,+)
COM Residual Voltage
Coil

(+,−) Varistor
COM Surge voltage DC
Coil

Varistor (+,−) suppressor 24 V 12 V


SOL.a
Coil

(−,+) Varistor S, Z Approx. 1 V


LED
SOL.a R, U Approx. 47 V Approx. 32 V
(−,+) LED

268
Series SY3000/5000/7000
Specific Product Precautions 4
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Continuous Duty Countermeasure for Surge Voltage Intrusion


 Sneak-in of surge voltage
Caution With non-polar type valves, at times of sudden interruption of
If a valve is energized continuously for a long period of time, the the loading power supply, such as emergency shutdown,
rise in temperature due to heat-up of the coil assembly may surge voltage intrusion may be generated from loading
cause a decline in solenoid valve performance, reduce service equipment with a large capacity (power consumption), and the
life, or have adverse effects on peripheral equipment. If the valve valve in a de-energized state may switch over (see Figure 1).
is energized continuously for a long period of time, be sure to use When installing a breaker circuit for the loading power supply,
a valve with power saving circuit. In particular, if three or more consider using a valve with polarity (with polarity protection
adjacent stations on the manifold are energized simultaneously diode), or install a surge absorption diode between the loading
for extended periods of time or if the valves on A side and B side equipment COM line and the output equipment COM line (see
are energized simultaneously for a long period of time, take Figure 2).
special care as the temperature rise will be greater.

Output circuit

Surge voltage
24 V
sol.1: Energized
0V

R −60 V
Surge voltage
Internal circuit

24 V
0V
sol.2: De-energized
R −60 V
Surge voltage
24 V
0V
Large capacity
R load: Energized −60 V

Relay
Power supply circuit breaker

24 VDC

Figure 1. Surge intrusion circuit example (NPN outlet example) (24 VDC)

Output circuit

Surge voltage
24 V
0V
sol.1: Energized
−2 V
R
Surge voltage
Internal circuit

24 V
0V
sol.2: De-energized
−2 V
R
Surge voltage
24 V
0V
Large capacity −2 V
R load: Energized

Countermeasure
Diode parts

– (Anode) + (Cathode)

Relay
Power supply circuit breaker

24 VDC

Figure 2. Surge intrusion circuit example (NPN outlet example) (24 VDC)

269
Series SY3000/5000/7000
Specific Product Precautions 5
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Light Indication Type 1: (Connector Connecting Base) Changing Connector Entry Direction
When equipped with indicator light and surge voltage suppressor,
the light window turns orange when solenoid a is energized, and it Caution
turns green when solenoid b is energized.
Connector direction for electrical entry of D-sub connector
Light
<IP40>, flat ribbon cable and PC wiring can be changed. If the
A side: Orange directional change is required, slide the lever on the side of the
B side: Green connector block to the FREE position, and then change the
direction as shown in the figure. Also, before connecting the
connector, be sure to return the lever to the LOCK position. (If
the lever is difficult to slide, move the connector a little bit to
make it easier to slide the lever.)
If an excessive force is applied on the connector in the LOCK
Solenoid a position, the connector block may be damaged. Also, using in
such a way that the connector floats in the FREE position, it may
cause the lead wire etc., to break. Thus, refrain from using in
Solenoid b these ways.

Type 5: (Metal Base) Changing Connector Entry Direction

Caution
E
Connector direction for electrical entry of D-sub connector, flat FRE
ribbon cable and PC wiring can be changed. If the directional LOCK
change is required, push the lever on both sides to remove the
connector and change the connector direction for electrical entry
as shown in the figure. Since lead wire assemblies are attached
to the connector, excessive pulling or twisting can cause broken
wires or other trouble. Also, take precautions so that lead wires
are not caught and pinched when installing the connector.
How to Order Manifold

Caution
The letter “s” is indicated on manifold blocks for the SY series
Type 1: (connector connecting base) as shown below. This
indication refers to the type of substrate assembly (single wiring)
inside the manifold blocks. When there is no symbol, double
wiring is used.
When the manifold specification sheet does not include a wiring
specification, all stations will be double wiring specification. In this
case, single and double solenoid valves can be mounted in any
position, but when a single valve is used, there will be an unused
control signal. To avoid this, indicate positions of manifold blocks
for single wiring specification and double wiring specification on a
manifold specification sheet. (Note that double, 3-or 4-position
valves cannot be used for manifolds blocks with single wiring
specification s.)

Single wiring
marked with s

270
Series SY3000/5000/7000
Specific Product Precautions 6
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Substrate Assemblies inside Manifolds Port Block Assembly and How to Change Piping Types between Top and Side

Caution Caution
Substrate assemblies inside of manifolds cannot be taken apart. For top ported type, the port size of A and B ports can be
Attempting to do so may damage parts. changed by switching the port block assemblies which are
mounted on the body. The piping method can also be changed by
switching the top ported type port block assembly with the side
ported type cover assembly. Also, it may cause air leakage if the
Fixation of DIN Rail Mounting Type Manifold mounting screws are not tightened securely enough when they
are switched. Take care to tighten to the correct tightening torque.
Caution Refer to page 247 for part numbers of port block assembly and
1. When the manifold is fixed with bolts on a mounting surface body cover assembly.
etc., it can be operated just by fixing on both ends of the DIN When switching them while valves are mounted on a manifold,
rail if the bottom surface of the DIN rail is entirely in contact remove the clip with a flat head screwdriver before switching the
with the mounting surface when mounted horizontally. port plugs and the One-touch fittings. It may cause air leakage if
However, if it is used with other mounting or with side or the mounting screws are not tightened or the clip is not inserted
reverse mounting, fix the DIN rail with bolts at regular intervals. securely enough when they are switched. Take care to tighten to
As a guide, insert bolts in 2 locations for 2-5 stations, 3 the correct tightening torque.
locations for 6-10 stations, 4 locations for 11-15 stations, 5
locations for 16-20 stations and 6 locations for 21-24 stations. Caution
2. When using the manifold with DIN rail in an environment where Tightening torque Mounting screw

any vibration or impact is applied to it, the DIN rail itself may be M2: 0.16 N·m (SY3000)
broken. In particular, if the installation surface vibrates when M3: 0.8 N·m (SY5000/7000)
mounting the manifold on the wall or if a load is directly applied Port block assembly
to the manifold, the DIN rail may be broken, causing the Thread piping
manifold to drop. When any vibration, impact, or load is applied
to the manifold, be sure to use the direct mounting manifold. Mounting screw

Port block assembly


One-touch fitting


: Part number is not shown on
Body cover assembly the body cover assembly.

 How to change while mounted on a manifold


Port block assembly
Refer to page 247.

Exchange the One-touch


fittings with the port plugs.
Clip
Tension bolt &
Refer to page 246.

Plate

Plug assembly
For SY3000
Removable by screwing an
M3 screw into the center hole.
Plug assembly
Plate Refer to page 248.
271
Series SY3000/5000/7000
Specific Product Precautions 7
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

Changing One-touch Fittings Changing One-touch Fittings

Caution Caution
By replacing One-touch fittings of valve or manifold base, it is "Bottom ported (Type 11)
possible to change the connection diameter of the 4(A), 2(B), Secure enough space between
1(P), 3/5(E) ports. the manifold blocks when the
When replacing the One-touch fittings, remove the clip or the plate is detached and attached.
plate and the plate mounting screws with a screwdriver before Plate part no. (10 pcs. included)
pulling the One-touch fittings off. Mount the One-touch fittings by Plate Series Part no.
following the removal procedure in reverse. SY5000
1 SY50M-10-4A
It may cause air leakage if the mounting screws are not tightened SY3000/5000 SY50M-10-5A
or the clip and the clip plate are not inserted securely enough Mixed mounting type
when they are switched. Take care to tighten to the correct SY7000 SY70M-10-4A
tightening torque. Refer to page 248 for part numbers of
1: A and B ports (ø8 and ø5/16") of
One-touch fittings for valve or manifold. the SY3000/5000 mixed mounting
Manifold block type are those for the SY5000.
 Valve

Other Tube Brands


One-touch fitting

Caution
1. When using other than SMC brand tube, confirm
Port plate that the following specifications are satisfied with
Caution respect to the tube outside diameter tolerance.
Tightening torque 1) Nylon tube within o0.1 mm
2) Soft nylon tube within o0.1 mm
M2: 0.16 N·m 3) Polyurethane tube within +0.15 mm
(SY3000) –0.2 mm
M3: 0.8 N·m Do not use tube which do not meet these outside diameter
(SY5000/7000) tolerances. It may not be possible to connect them, or they
 Plug-in metal base may cause other trouble, such as air leakage or the tube
"Side ported (Type 50) "Bottom ported (Type 51) pulling out after connection.
Clip

One-touch One-touch Fittings


fitting
 Tube attachment/detachment for One-touch fittings
Plate 1) Tube attachment
1. Take a tube having no flaws on its periphery and cut it off
Plate mounting at a right angle. When cutting the tube, use tube cutters
screw TK-1, 2 or 3. Do not use pinchers, nippers or scissors,
etc. If cutting is done with tools other than tube cutters,
Plate assembly part no. the tube may be cut diagonally or become flattened, etc.,
Clip part no. (10 pcs. included) (10 pcs. included) making a secure installation impossible, and causing
Series Part no. Series Part no. problems such as the tube pulling out after installation or
SY3000 SY30M-19-2A SY3000 SY30M-10-3A air leakage. Allow some extra length in the tube.
SY5000 SY50M-19-2A SY5000 SY50M-10-6A 2. Grasp the tube and push it in slowly, inserting it securely
SY7000 SY70M-19-2A SY7000 SY70M-10-7A all the way into the fitting.

: Including mounting screw 3. After inserting the tube, pull on it lightly to confirm that it
 Plug-in connector connecting base will not come out. If it is not installed securely all the way
into the fitting, this can cause problems such as air
"Side ported (Type 10) leakage or the tube pulling out.
Port plate SUP/EXH block Clip part no. (10 pcs. included) 2) Tube detachment
Clip Series Part no.
1. Push in the release button sufficiently, pushing its collar
One-touch SY3000 SY30M-19-1A
fitting equally around the circumference.
SY5000
1 SY50M-19-6A
2. Pull out the tube while holding down the release button
SY3000/5000 SY50M-19-1A so that it does not come out. If the release button is not
Mixed mounting type
pressed down sufficiently, there will be increased bite on
SY7000 SV3000-70-1A
the tube and it will become more difficult to pull it out.

1: A and B ports (ø8 and ø5/16") of 3. When the removed tube is to be used again, cut off the
the SY3000/5000 mixed mounting portion which has been chewed before reusing it. If the
type are those for the SY5000. chewed portion of the tube is used as is, this can cause

: If the port plate for the SUP/EXH block
trouble such as air leakage or difficulty in removing the
is required, please contact SMC.
Manifold block tube.
272
Series SY3000/5000/7000
Specific Product Precautions 8
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

One-touch Fittings

Caution
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings
to be used should first be confirmed in their respective catalogs.
Fittings whose compliance with the SY series is already confirmed are stated below. If the fitting within the applicable range is selected,
there will not be any interference.

Applicable Fittings: Series KQ2H, KQ2S


Port Applicable tube O.D.
Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY3:30-::-M5 4A, 2B M5
KQ2S
KQ2H
1P, 5EA, 3EB 1/8
KQ2S
KQ2H
SY3000 X, PE M5
SS5Y3-50/51/52 (R) KQ2S
Manifold base KQ2H
1/8
KQ2S
4A, 2B
KQ2H
M5
KQ2S

Port Applicable tube O.D.


Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY5:30-::-01 4A, 2B 1/8
KQ2S
KQ2H
1P, 5EA, 3EB 1/4
KQ2S
SY5000 KQ2H
X, PE M5
SS5Y5-50/51/52 (R) KQ2S
Manifold base KQ2H
1/4
KQ2S
4A, 2B
KQ2H
1/8
KQ2S

Port Applicable tube O.D.


Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY7:30-::-02 4A, 2B 1/4
KQ2S
KQ2H
1P, 5EA, 3EB 3/8
KQ2S
SY7000
SS5Y7-50/51/52 (R) KQ2H
X, PE M5
Manifold base KQ2S
KQ2H
4A, 2B 1/4
KQ2S
 Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
CompoNet™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

273
Revision history
Edition B * Added the EX260 Integrated-type (For Output) Serial Transmission System.
* Added EtherNet/IP™ and EtherCAT to the EX600 Integrated-type (For Input/Output)
Serial Transmission System (Fieldbus System).
* Additional Options:
· Interface regulator assembly · Dual flow fitting
· Individual SUP block assembly · Name plate for manifolds
· Individual EXH block assembly
* Changed the part numbers for A, B port mixed sizes for plug-in connector connecting
bases for Type 10 (Side ported), Type 11 (Bottom ported), Type 12 (Top ported).
* Deleted the mixed specification for A, B port piping specification for plug-in connector
connecting base for Type 12 (Top ported).
* Number of pages from 148 to 164 PY
Edition C * Added the SY7000.
* Added plug-in sub-plate (SY3000/5000).
* Added with residual pressure release valve (SY5000).
* Added with safety slide locking manual override.
* Added D-sub connector [IP67] manifold.
* Added PC wiring (with power supply terminal) manifold.
* Number of pages from 164 to 260 SO
Edition D * Added vacuum release valve with restrictor.
* Added the dual port EX600 EtherNet/IP™ product.
* Added the products for the EX500 Gateway Decentralized System 2.
* Added SUP stop valve spacer (with residual pressure release valve).
* Added with residual pressure release valve (SY7000).
* Number of pages from 260 to 276 UQ
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
http://www.smcworld.com
© 2016 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice D-G 1st printing NY printing UQ 11030KS Printed in Japan.
and any obligation on the part of the manufacturer.

You might also like