X-FLOW SEAFLEX 64

ULTRAFILTRATION MEMBRANE
MEMBRANE ELEMENT DATASHEET

SEAFLEX HP
ARTICLE CODE: 22F1FL895H

GENERAL INFORMATION CLEANING CHEMICAL RESISTANCE

Seaflex 64 is used as pre-treatment for Sodium Hypochlorite As a good working practice and in order to
seawater reverse osmosis. Mode of operation - Typical 200 ppm, at ≤ 40 ºC at ≥ pH 10 maximise the lifetime of the membrane it is
is feed-and-bleed with a minor crossflow - Maximum 500 ppm advised to reduce the membrane exposure
or dead-end mode with regular backwash - 250.000 ppm hours cumulative; ≥ pH 10 to oxidising agents to a minimum. Exposure
(permeate only) and chemically enhanced limits are also affected by temperature,
Chlorine Dioxide
backwash. The Seaflex 64 module is used in pH and the presence of metals. In order
- Typical 1 ppm, at ≤ 40 ºC
applications for standard seawater with low to not to exceed maximum exposure limits,
- Maximum 2 ppm
moderate TSS and/or organic load. membranes must be preserved free of any
- 90.000 ppm hours cumulative; pH 11
oxidising agent when the plant is stopped.
Hydrogen Peroxide
GENERAL SOLVENT RESISTANCE Acids
- Typical 200 ppm, at ≤ 40 ºC
Hydrochloric Acid ++
- Maximum 500 ppm
Nitric Acid ++
Since the resistance of the membrane to - 350.000 ppm hours cumulative
Sulphuric Acid ++
solvents strongly depends on the actual
Note: Phosphoric Acid ++
process conditions, the indications given
The above figures for oxidant contact Acetic Acid ++
below should only be considered as
represent the membrane resistance to Citric Acid ++
guideline.
each individual oxidizing agent. The total
pH > 2 during filtration
Acids ++ combined exposure for Sodium Hypochlorite
pH > 1 during cleaning
Bases ++ and Chlorine Dioxide will be calculated as
Organic esters, ketones, follows: Bases
ethers - Sodium Hydroxide (<4%) ++
Aliphatic alcohols + Combined exposure (NaOCl + ClO2) = 2.6 x
Potassium Hydroxide (<4%) + +
Aliphatic hydrocarbons + Exposure to ClO2 (in ppm hours)+ Exposure
Halogenated hydrocarbons -- to NaOCl (in ppm hours) < 250.000 ppm pH < 12 during filtration
Aromatic hydrocarbons -- hours pH < 13 during cleaning
Polar organic solvents --
Oils ++

MEMBRANE CHARACTERISTICS ELEMENT SPECIFICATIONS

• Hydrophilic membrane composed of


Membrane Effective Feed Module Permeate
a blend of polyvinylpyrrolidone and connection D0 length L0 connection d0
diameter membrane
polyethersulfone [mm/mil] area [m²/ft²] [mm/Inch] [mm/Inch] [mm/Inch]
• A nominal pore size of 20 nm
0.83 [32.7] 64 [687] 220.0 [8.66] 1537.5 [60.51] 42.6 [1.68]
• Structure asymmetric/microporous
• High performance and a very good anti-
fouling behaviour
• Typical permeate quality SDI<3, turbidity
<0,1 NTU

ADVANCED FILTRATION SEAFLEX 64


X-FLOW SEAFLEX 64
ULTRAFILTRATION MEMBRANE
MEMBRANE ELEMENT DATASHEET

OPERATING SPECIFICATIONS

• Backwash water should be free of element to sudden temperature changes,


Max. Max. trans- Max.
Temp. particulates and should be of UF permeate particularly decreasings. Bring the module
system membrane backflush
range quality or better or element back to ambient operating
pressure pressure pressure
temperature slowly (max. value 3 °C/min).
• Backwash pumps should preferably be Failure to adhere to this guideline can
[kPa/psi] [kPa/psi] [kPa/psi] [°C/°F] made of non-corroding materials, e.g., result in irreparable damage
300 300 300 0-40 plastic or stainless steel. If compressed
[43] [43] [43] [32-104] air is used to pressurize the backwash Operation of membrane modules at any
water, do not allow a two-phase air/water combination of maximum limits of pH,
mixture to enter the element concentration, pressure or temperature,
during cleaning or production, will influence
• To avoid mechanical damage, do not the membrane lifetime.
subject the membrane module or
TECHNICAL SPECIFICATIONS

Weight Specifications Process Characteristics (Water, 20 ºC)


Dry weight of membrane element
ca. 34 kg [75 lbs] Hydraulic Crossflow Pressure-drop Pressure-drop
membrane flow rate across module across module
Membrane element filled with water diameter (*) at 1 m/s at 2 m/s
ca. 66 kg [145 lbs]
[mm/mil] [m3/h/gpm] [kPa/psi] [kPa/psi]
Materials of Construction
Housing PVC white 0.83 [32.7] 26.9*v [36*v] 64 [9] 136 [20]
Flow distributor PVC/PP
Potting PU resin (*) superficial velocity (v) in m/s [ft/s]
Membrane PES/PVP

STORAGE

New membrane modules can be stored Storage temperature should be between


as supplied in the original packaging. The 0 and 40 °C. Pentair instructions for
membrane modules contain an aqueous transport and storage are to be followed
preservation solution of glycerine (20wt%) at all times and available upon request. It
and sodium metabisulfite (1wt%) to prevent is recommended to have the membrane
dehydration and control bacterial growth. modules installed into the UF skids and
The membrane modules are packed in commissioned as soon as possible. The
plastic bags which are vacuum sealed to membrane shelf life is maximum 6 months
keep the moisture in the module. Membrane from the date the modules are announced
modules should be stored in a dry, normally ready for delivery ex works Pentair
ventilated place, away from sources of heat warehouse. After expiry of the shelf life all
ignition and direct sunlight. warrantees are null and void.

X-FLOW BV
P.O. BOX 739, 7500 AS ENSCHEDE, NETHERLANDS WWW.X-FLOW.COM
Note: The information and data contained in this document are based on our general experience and are believed to be correct. They are given in good faith
and are intended to provide a guideline for the selection and use of our products. Since the conditions under which our products may be used are beyond our
control, this information does not imply any guarantee of final product performance and we cannot accept any liability with respect to the use of our products.
The quality of our products is guaranteed under our conditions of sale. Existing industrial property rights must be observed.
DS SEAFLEX 64 EN 4016 © 2016 Pentair. All Rights Reserved. ISO 9001