Be Sure 9T5364 Relief Valve (Part Of 9T4789 Counterbalance


Valve Group) Is Correctly Adjusted{4340}
SMCS - 4340 

D6H, D7H, D8N Tractors Equipped With Differential Steering  

Some replacement 9T5364 Relief Valve Groups have been received from the Parts Department with 
loose locknuts and questionable adjustment. The 9T5364 Relief Valve Group is part of the 9T4789 
Counterbalance Valve Group in the differential steering system. See Illustrations 1 and 2.)  

 
 
Illustration 1. Location of 9T5364 Relief Valve Groups on 9T4789 Counterbalance Valve Group.   

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/s... 2/3/2012
D7H & D7H LGP TRACTOR / POWERSHIFT / 3XG00001-UP (MACHINE) POWERE... Page 2 of 3

 
 
Illustration 2. Location of cap (1), locknut (2), and adjustment screw (3) in 9T5364 Relief Valve Group.  

If a 9T5364 Relief Valve Group is received with a loose locknut, use one of the following methods to 
adjust the valve group. Either of the methods will set the valve group near the specified 42 000 kPa 
(6100 psi) at 5 L/min (1.3 U.S. gpm).  

Adjusting The 9T5364 Valve Group On The Machine


1. Install a 52 000 kPa (7500 psi) gauge in the circuit.  

2. Start the engine and go to stall steer (at low idle) toward the side in which the new valve was 
installed.  

3. Remove cap (1), loosen locknut (2), and back out (turn counterclockwise) adjustment screw (3) until 
the gauge reading is below the 38 000 kPa (5500 psi) pump cut-in pressure.  

4. Turn adjustment screw (3) in until the pressure gets to 38 000 kPa (5500 psi). Do not go above 38 000 
kPa (5500 psi).  

5. Turn adjustment screw (3) in another one-quarter turn and tighten locknut (2). Install cap (1).  

Adjusting The 9T5364 Relief Valve Group On A Test Bench


1. Install a 1U7770 Manifold Test Block on the test bench.  

2. With the oil flow set at 1.5 to 1.9 L/min (0.4 to 0.5 U.S. gpm), turn adjustment screw (3) to set the 
valve to approximately 41 200 ± 400 kPa (5975 ± 58 psi).  

3. Tighten locknut (2) and replace cap (1).   

Copyright 1993 - 2012 Caterpillar Inc.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/s... 2/3/2012
D7H & D7H LGP TRACTOR / POWERSHIFT / 3XG00001-UP (MACHINE) POWERE... Page 3 of 3

All Rights Reserved.   Fri Feb 3 15:29:08 UTC+0400 2012


Private Network For SIS Licensees.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/s... 2/3/2012

You might also like