Functions, Measurement and control relays -

schemes Zelio Control


Industrial relays
Plug-in liquid level control relays RM 84 870

b Controlling the levels of conductive liquids Operating principle


b Regulation of two thresholds: Control of maximum and/or minimum levels of conductive liquids (tap water, sea
v
1 v
minimum,
maximum.
water, waste water, chemical solutions, coffee ...).
b Emptying function. The operating principle is based on measurement of the apparent resistance of the
b Plug-in, 8 or 11-pin. liquid between two submerged probes. When this value is less than the threshold
b Sensitivity adjustable from 5 kΩ to 100 kΩ. setting on the front panel of the device, the output relay changes state. To avoid
electrolytic phenomena, an a.c. current runs across the probes.

2 Applications in the food-processing, chemical industries, etc.


Regulation of two levels, minimum/maximum
The output relay changes state when the level of the liquid reaches the maximum
level probe, with the minimum level probe submerged. It returns to its initial state
when the minimum level probe is no longer in contact with the liquid.

3 Emptying control

Un

Energisation of the
device
T
Max. level

4 Min. level Level being controlled

Output relay Down


Emptying function

Connection scheme
5 R S T
11-pin 8-pin

5 6 4 5
7
4
6 3 8
9
3

2
6
7
2 10
1 11 1 8

c b a

7 Input

a - Maximum
b - Minimum
a
c - Common
b
M P c

8 For RM 84 870 807 (special 11-pin base fitting), pin 5 must be connected to “a”
(maximum) and pin 7 must be connected to “c” (common).

10

2 28546-EN_Ver5.1
References, Measurement and control relays -
characteristics, Zelio Control
dimensions Industrial relays
Plug-in liquid level control relays RM 84 870

References
Liquid level control relays
Number of pins Voltage Reference Weight
kg
1
8-pin a 24 V RM 84 870 301 0.140

a 120 V RM 84 870 303 0.140

a 230 V RM 84 870 304 0.140

11-pin a 24 V RM 84 870 306 0.140


2
a 120 V RM 84 870 308 0.140

RM 84 870 303 a 230 V RM 84 870 309 0.140

Special 11-pin base fitting a 230 V RM 84 870 807 0.190

Accessories
3
Description Sold in lots of Unit reference Weight
kg
11-pin socket 10 RUZ 1A 0.067

Note: The probe cable, with a maximum length of 100 metres (recommended probes,
see page 28550/2) need not be screened, but it is inadvisable to fit it in parallel with the power
supply cables.
4
Screened cable may be used, with the screening connected to the common.

10

28546-EN_Ver5.1 3