You are on page 1of 78

Publication 25182

(Revision R, 8/2015)
RESTRICTED—NOT FOR GENERAL DISTRIBUTION

Energy Controls Standard Products


Product Information

Updated to 7 July 2015


Contents
1—All Electric Governors ............................................................................................................... 5
1. ProAct ISC (Integrated Speed Control) Actuators/Throttle Bodies ................................... 5
2. ProAct Accessories .......................................................................................................... 5
3. Flo-Tech Speed Controls/Actuators/Throttle Bodies ........................................................ 5
4. EPG .................................................................................................................................. 6
5. R-Series Electric Actuators............................................................................................. 76

2—APECS Products ........................................................................................................................ 8


1. APECS Linear Actuators .................................................................................................. 8
2. APECS Rotary Actuators.................................................................................................. 9
3. APECS Controllers ......................................................................................................... 11
4. APECS Speed Switches and Sensors ........................................................................... 13
5. APECS Accessories ....................................................................................................... 15

3—Electronic Controls .................................................................................................................. 16


1. 2301A Controls............................................................................................................... 16
2. 2301E Electronic Load Sharing and Speed Controls ..................................................... 16
3. 2300E Electronic Load Sharing and Speed Controls ..................................................... 16
4. 723 Controls ................................................................................................................... 16
5. 723PLUS Controls .......................................................................................................... 17
6. 828 Control (723PLUS) Hardware Platform for Distributors ........................................... 17
7. Custom Control Platforms (AtlasSC / Atlas-II) ................................................................ 17
8. Engine System Custom Controls (733, 766, In-Pulse 2, ECM3) .................................... 18

4—Turbine Controls and Associated Devices ............................................................................ 19


1. 2301E-ST Steam Turbine Controls ................................................................................ 19
2. Peak 150 Steam Turbine Controls ................................................................................. 19
3. 505 Steam Turbine Controls........................................................................................... 19
4. 5009FT Steam Turbine Controls .................................................................................... 20
5. Standard MicroNet Turbine Control Kits ......................................................................... 20
6. GTC Gas Turbine Controls ............................................................................................. 20
7. Servo Position Controllers (replace Digital Remote Final Drivers) ................................. 20
8. ProTech Overspeed Protection Devices ........................................................................ 21
9. MicroNet System Modules, Cables, & Accessories ........................................................ 22
10. DVP Digital Valve Positioner .......................................................................................... 30
11. Magnetic Pickups ........................................................................................................... 31
12. Active Proximity Probes.................................................................................................. 31

5—Software Licenses ................................................................................................................... 32

6—Power Generation Products .................................................................................................... 37


1. easYgen Stand-alone Genset Controls .......................................................................... 37
2. easYgen Paralleling Genset Controls ............................................................................. 38
3. EGCP-2 Generator Controls........................................................................................... 42
4. Switchgear Controls ....................................................................................................... 43
5. Synchronizers ................................................................................................................. 44
6. Load Share Controls ...................................................................................................... 45
7. Digital Multi-Function Relays .......................................................................................... 46
8. Expansion Modules ........................................................................................................ 47
9. Accessories and Spare Parts ......................................................................................... 47

7—Power Distribution Products................................................................................................... 49


1. HighPROTEC Ordering Code......................................................................................... 49
2. HighPROTEC Services .................................................................................................. 58
3. HighPROTEC Accessories ............................................................................................. 58

Woodward reserves the right to update any portion of this publication at any time. Information provided by
Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless
otherwise expressly undertaken.
Manual 25182
Copyright © Woodward 1998–2015
All Rights Reserved
Energy Controls Product Information Manual 25182

Contents
8—Electro-Hydraulic Governors & Actuators............................................................................. 59
1. TG Turbine Governors ................................................................................................... 59
2. TGE Turbine Actuators .................................................................................................. 60
3. VariStroke Actuators ...................................................................................................... 61
4. Servo Boosters .............................................................................................................. 69
5. CPC Current-to-Pressure Converter .............................................................................. 69
6. EM Electric Actuators ..................................................................................................... 69
7. TM Actuators (Linear) .................................................................................................... 69
8. Turbine Shutdown Trip Block Assemblies ...................................................................... 69

9—Ignition Products ..................................................................................................................... 70


1. Coils ............................................................................................................................... 70
2. Shielded Harnesses ....................................................................................................... 70
3. Ignition Controllers ......................................................................................................... 70

10—L-Series Actuators and Integrated Speed Controls ............................................................ 71


1. L-Series Speed Control–Actuator Only .......................................................................... 71
2. L-Series Speed Control–Actuator with ITB..................................................................... 71
3. L-Series Process Control ITB (AFR Control).................................................................. 71
4. L-Series Speed Control–Actuator with ITB & Venturi Mixer (MAS) ................................ 71
5. L-Series Diesel Engine Applications .............................................................................. 71
6. L-Series Speed Control with ITB & Trim Valve .............................................................. 71
7. L-Series Positioner with ITB ........................................................................................... 72
8. L-Series Accessories ..................................................................................................... 72

11—F-Series Actuators and Actuator with ITB ........................................................................... 73


1. F-Series Positioners ....................................................................................................... 73
2. Accessories.................................................................................................................... 73

12—R-Series Actuators ................................................................................................................ 73

13—TecJet Fuel Control Valves ................................................................................................... 73

14—Gas Turbine Valves ............................................................................................................... 74


1. GS6 Gas Fuel Valve Actuator w/ On-board Driver ......................................................... 74
2. GS16 Gas Fuel Valve Actuator w/ On-board Driver ....................................................... 74
3. GSOV25HT Gas Fuel Shutoff Valve .............................................................................. 74
4. LQ6 Liquid Fuel Valve Actuator w/ On-board Driver ...................................................... 74
5. LQ25 Standard Valves ................................................................................................... 74
6. LSOV25 Liquid Fuel Shutoff Valve................................................................................. 74
7. Electric Actuator/Driver .................................................................................................. 74

15—Air/Fuel Ratio Controls.......................................................................................................... 75


1. E3 (All Encompassing Engine and Emission Control) .................................................... 75
2. Accessories.................................................................................................................... 75

16—Electronic Accessories ......................................................................................................... 76


1. Miscellaneous Accessories ............................................................................................ 76
2. Potentiometers ............................................................................................................... 76
3. Digital Reference Units .................................................................................................. 76
4. PM Motor Controls ......................................................................................................... 76
5. Swift Driver..................................................................................................................... 76

17—Mechanical-Hydraulic Controls ............................................................................................ 77

18—Woodward Authorized Facilities .......................................................................................... 77

19—Repair and Remanufacturing Services ................................................................................ 77

4 Woodward
Manual 25182 Energy Controls Product Information

1—All Electric Governors


All electric governor systems consist of five major components, one from each of the
following categories: Actuator, Speed Control, Magnetic Pickup, Wiring Harness, and
Installation Kit. The EPG systems may be expanded by including one or more items from
the Electronic Accessories Category.
Steady State Torque Output:
Model I—1.3 N·m / 11.5 lb-in
Model II—2.6 N·m / 23 lb-in
Model III—5.2 N·m / 46 lb-in
Model IV—10.4 N·m / 92 lb-in
Part
Number
1. ProAct™ ISC (Integrated Speed Control) Actuators/Throttle Bodies
A. PISC Speed Control
Model I 8404-203
Model II 8404-204
Model III 8404-213
Model IV 8404-214
B. PISC Integrated Throttle Bodies
PISC II, 137 mm, 85 °C flow medium max. temp. 8235-198
PISC II, 137 mm, 205 °C flow medium max. temp. 8235-361
PISC II, 139 mm, 85 °C flow medium max. temp. 8235-305
PISC II, 152 mm, 205 °C flow medium max. temp. 8235-339
PISC II, 154 mm, 205 °C flow medium max. temp. 8235-337
PISC III, 169 mm, 100 °C flow medium max. temp. 8235-351
PISC III, 178 mm, 85 °C flow medium max. temp. 8235-360
PISC III, 180 mm, 85 °C flow medium max. temp. 8235-350

2. ProAct™ Accessories
Connector ProAct ISC 1635-1113
Lever Kit .625-36 5394-181

3. Flo-Tech™ Speed Controls/Actuators/Throttle Bodies


A. Flo-Tech Speed Controls
12 Vdc Speed Control 8290-196
24 Vdc Speed Control 8290-195
Contact channel partner or sales support engineer for throttle body sizing or for other applications.

B. Flo-Tech Actuators with Integral Throttle Bodies


Preferred:
33 mm bore, Packard Connector, PWM 8235-132
75 mm bore, Deutsch Connector, PWM 8235-147
Non-Preferred:
33 mm bore, Packard Connector, 4-20 mA 8235-163
60 mm bore, Deutsch Connector, 0-200 mA 8235-166
68 mm bore, Deutsch Connector, 0-200 mA 8235-145
68 mm bore, Packard Connector, 0-200 mA 8235-152
68 mm bore, Bendix Connector, 0-200 mA 8235-153
75 mm bore, Deutsch Connector, 0-200 mA 8235-146

Woodward 5
Energy Controls Product Information Manual 25182

4. EPG
A. Actuator
Model 512, 12 Vdc 8256-022
Model 524, 24 Vdc 8256-021
Model 1712, 12 Vdc 8256-017
Model 1724, 24 Vdc 8256-016

Part
Number
B. Speed Control (Isochronous)
The following part numbers represent a 3000–6000 Hz range; contact Woodward for part numbers
of different speed ranges. All have Start Fuel Limit.
12 Vdc, 512 or 1712 SC for Diesel or Turbine 8290-186
12 Vdc, 512 or 1712 SC for Natural Gas or Gasoline 8290-187
24 Vdc, 524 or 1724 SC for Diesel or Turbine 8290-184
24 Vdc, 524 or 1724 SC for Natural Gas or Gasoline 8290-185
24 Vdc, 4024 Speed Control for Diesel or Turbine 8290-148
24 Vdc, 4024 Speed Control for Natural Gas or Gasoline 8290-147

C. Speed Control (Droop) For 512/524 and 1712/1724 Series Systems


The following part numbers represent a 3000–6000 Hz range; contact Woodward for part numbers
of different speed ranges.
12 Vdc, Diesel or Turbine 8290-192
24 Vdc, Diesel or Turbine 8290-191
24 Vdc, Natural Gas or Turbine 8290-045

D. Wiring Harness
10 ft.–MPU, 15 ft.-Actuator, 15 ft.–Battery 8924-621
15 ft.–MPU, 25 ft.-Actuator, 25 ft.–Battery 8924-620
25 ft.–MPU, 30 ft.-Actuator, 30 ft.–Battery 8924-645

E. Linkage Kit (EPG Actuators)


General Linkage Kit, (1712/1724) 1 Lever, (3960-059)
2 Rod Ends, 16” .250 Rod 8924-414
General Linkage Kit, (1712/1724) 1 Lever, (3979-007)
2 Rod Ends, 16” .312 Rod 8924-370
General Linkage Kit, (4024) 1 Lever, (3699-027)
2 Rod Ends, 16" .312 Rod 8923-093
Lever 4024, EG-10P (.5x36 Serrations) 3699-027

F. Installation Kits (Kits do not include actuator, speed control, MPU or wiring harness.)
ENGINES EQUIPPED WITH ROBERT BOSCH FUEL PUMPS
Bosch RS/RSV Governor on LH side of engine 8924-595
CATERPILLAR ENGINES (1712, 1724, OR 4024 ONLY)
D3304, 3306 CAT Mechanical Governor (before 1982) 8924-601
3208, CAT Mechanical Governor 8924-608
3406, B Series Fuel System (after 1982) 8924-782
3306, B Series Fuel System (after 1982) 8924-642
3408B, 3412B (4024) Speed Setting Lever 8924-743
CUMMINS ENGINES (1712, 1724 UNLESS OTHERWISE NOTED)
N/NT/NTA-855 8924-604
KT/KTA-38 GS & KTA-50 GS 8924-607
DETROIT DIESEL ENGINES (1712, 1724 UNLESS OTHERWISE NOTED)
V71 (12 cyl. max) or V92 (8 cyl. max) 8924-863
V71 16 cylinder or V92 12 or 16 cylinder(4024) 8923-072
V149 (4024) 8923-071
3, 4-71 (Exhaust on Left,512/524) 8924-862
3, 4, 6-71 Inline, (Exhaust on Right, 1712/1724) 8924-584
3, 4, 6-71 Inline, (Exhaust on Left, 1712/1724) 8924-591

6 Woodward
Manual 25182 Energy Controls Product Information

5. R-Series Electric Actuators


A. Release 1
R-11 8410-001
R-30 8410-002

B. Release 2
Never released

C. Release 3
R-11 8410-007
R-30 8410-008

Woodward 7
Energy Controls Product Information Manual 25182

2—APECS™ Products
Old Part WISE Part
Number Number
1. APECS™ Linear Actuators
DYNA 2000 (work capacity 0.25 ft-lb, standard shaft seal & linear ball bushings, output travel
0.775–0.825”/19.68–20.95 mm)
12 Vdc DYNC-10202-000-0-12 DC10202-000-012
24 Vdc DYNC-10202-000-0-24 DC10202-000-024
DYNA 2500 (work capacity 0.50 ft-lb, standard shaft seal & linear ball bushings, output travel
0.775–0.825”/19.68–20.95 mm)
12 Vdc DYNC-10502-000-0-12 DC10502-000-012
24 Vdc DYNC-10502-000-0-24 DC10502-000-024

Voltage Mount Plunger Spring (lbf) Description Part Number


APECS 0175P Series, Push Type
12 Flange 1/4-28 0.25-6.0 0175P-12A2LS2 8175-1013
12 Flange M6 0.5-5.25 0175P-12A3LS1 8175-1014
12 Flange 1/4-28 0.5-5.25 0175P-12A2LS1 8175-1017
24 Flange M6 0.25-6.0 0175P-24A3LS2 8175-1026
APECS 0175 Series, Pull Type
12 Flange 1/4-28 0.5-5.25 0175-12A2LS1 8175-1001
12 Flange M6 0.5-5.25 0175-12A3LS1 8175-1002
24 Base 1/4-28 0.25-6.0 0175-24E2LS2 8175-1003
12 Base 1/4-28 0.5-5.25 0175-12E2LS1 8175-1004
24 Flange M6 0.5-5.25 0175-24A3LS1 8175-1009
APECS 0250P Series, Push Type
12 Base M6 1.6-11.4 0250P-12E3LS1 8250-1000
12 Base 1/4-28 1.6-11.4 0250P-12E2LS1 8250-1005
24 Flange M6 1.6-11.4 0250P-24A3LS1 8250-1010
12 Flange M6 1.6-11.4 0250P-12A3LS1 8250-1011
24 Base M6 1.6-11.4 0250P-24E3LS1 8250-1012
12 Flange 1/4-28 0.75-14 0250P-12A2LS2 8250-1014
12 Flange 1/4-28 1.6-11.4 0250P-12A2LS1 8250-1017
24 Base 1/4-28 1.6-11.4 0250P-24E2LS1 8250-1023
24 Flange 1/4-28 1.6-11.4 0250P-24A2LS1 8250-1026
APECS 0250 Series, Pull Type
12 Base 1/4-28 1.6-11.4 0250-12E2LS1 8250-1001
24 Flange 1/4-28 1.6-11.4 0250-24A2LS1 8250-1003
12 Base M6 1.6-11.4 0250-12E3LS1 8250-1004
24 Flange M6 1.6-11.4 0250-24A3LS1 8250-1006
24 Base M6 1.6-11.4 0250-24E3LS1 8250-1008
12 Flange 1/4-28 1.6-11.4 0250-12A2LS1 8250-1009
12 Flange M6 0.75-8.8 0250-12A3LS3 8250-1013
12 Base M6 0.75-8.8 0250-12E3LS3 8250-1015
12 Base 1/4-28 0.75-8.8 0250-12E2LS3 8250-1016
12 Flange 1/4-28 0.75-14 0250-12A2LS2 8250-1018
12 Flange 1/4-28 0.75-8.8 0250-12A2LS3 8250-1019
12 Flange M6 1.6-11.4 0250-12A3LS1 8250-1020
24 Base 1/4-28 1.6-11.4 0250-24E2LS1 8250-1021

8 Woodward
Manual 25182 Energy Controls Product Information

Voltage Mount Plunger Spring (lbf) Description Part Number


APECS 0300P Series, Push Type
12 Flange 1/4-28 1.0-22.0 0300P-12A2LS2 8300-1509
24 Flange 1/4-28 1.0-22.0 0300P-24A2LS2 8300-1511
12 Flange M6 4.25-19.5 0300P-12A3LS1 8300-1512
24 Flange M6 4.25-19.5 0300P-24A3LS1 8300-1513
24 Base M6 4.25-19.5 0300P-24E3LS1 8300-1514
APECS 0300 Series, Pull Type
12 Base 1/4-28 4.25-19.5 0300-12E2LS1 8300-1500
12 Base 1/4-28 2.13-9.75 0300-12E2LS3 8300-1501
24 Flange 1/4-28 4.25-19.5 0300-24A2LS1 8300-1502
24 Base M6 2.13-9.75 0300-24E3LS3 8300-1503
24 Flange M6 4.25-19.5 0300-24A3LS1 8300-1504
12 Base M6 4.25-19.5 0300-12E3LS1 8300-1507
12 Flange 1/4-28 1.0-22.0 0300-12A2LS2 8300-1508
24 Base M6 4.25-19.5 0300-24E3LS1 8300-1510
12 Base M6 2.13-9.75 0300-12E3LS3 8300-1518
24 Base 1/4-28 4.25-19.5 0300-24E2LS1 8300-1520
12 Flange 1/4-28 4.25-19.5 0300-12A2LS1 8300-1521

Old WISE Suggested User


Part Number Part Number Net Price
Linkage-free Integral Actuators
Kubota Super 5, 12 Vdc SA-4573-12
Kubota 3300, 12 Vdc SA-4828-12
Yanmar TNE, 12 Vdc SA-4574-12
Perkins 700, 12 Vdc SA-4777-12
Mitsubishi, SL&L, 12 Vdc, w/ locknut SA-4837-12
Kubota Super 5, 24 Vdc SA-4573-24
Kubota 3300, 24 Vdc SA-4828-24
Yanmar TNE, 24 Vdc SA-4574-24
Perkins 700, 24 Vdc SA-4777-24
Mitsubishi SL&L, 24 Vdc, w/ locknut SA-4837-24
Actuators with Mounting Hardware & Linkage
Daihatsu DM950, 12 Vdc SA-4779-12

2. APECS™ Rotary Actuators


Plus 1 (work capacity 1 ft-lb, contactless potentiometer feedback, output shaft rotates 45
degrees)
CW to increase fuel, standard head position,
12 Vdc DYNC-11000-004-0-12 DC11000-004-012
CW to increase fuel, standard head position,
24 Vdc DYNC-11000-004-0-24 DC11000-004-024
CW to incr fuel, std hd pos, 24 Vdc, side-mount
actuator w/ high vib head DYNC-11000-304-0-24 DC11000-304-024
CW to incr fuel, act head positioned 180° from
std DYNC-11000, 24 Vdc DYNC-11001-004-0-24 DC11001-004-024
CW to incr fuel, act head positioned 90° CCW from
std DYNC-11000, 24 Vdc DYNC-11002-004-0-24 DC11002-004-024

Woodward 9
Energy Controls Product Information Manual 25182
Old Part WISE Part
Number Number
CCW to increase fuel, standard head position,
24 Vdc DYNC-11004-004-0-24 DC11004-004-024
CCW to incr fuel, act head positioned 180° from std DYNC-11004, 24 Vdc, side-mount
actuator w/ high vib head DYNC-11006-304-0-24 DC11006-304-024
DYNA 8000 (work capacity 1.0 ft-lb, current feedback 12 or 24 Vdc, terminal strip
connection)
Output shaft rotates 35°, CW to incr fuel, std
head pos, 12 Vdc DYNC-11020-000-0-12 DC11020-000-012
Output shaft rotates 35°, CW to incr fuel, std
head pos, 24 Vdc DYNC-11020-000-0-24 DC11020-000-024
CW to incr fuel, std head pos, side-mounted
actuator, 12 Vdc DYNC-11020-300-0-12 DC11020-300-012
CW to incr fuel, std head pos, side-mounted
actuator, 24 Vdc DYNC-11020-300-0-24 DC11020-300-024
CW to incr fuel, act head pos 180° from std
DYNC-11020, 12 Vdc DYNC-11021-000-0-12 DC11021-000-012
CW to incr fuel, act head pos 180° from std
DYNC-11020, 24 Vdc DYNC-11021-000-0-24 DC11021-000-024
CW to incr fuel, side-mounted actuator, act head pos 180° from std
DYNC-11020, 12 Vdc DYNC-11021-300-0-12 DC11021-300-012
CW to incr fuel, side-mounted actuator, act head pos 180° from std
DYNC-11020, 24 Vdc DYNC-11021-300-0-24 DC11021-300-024
CW to incr fuel, act head pos 90° CCW from std
DYNC-11020, 12 Vdc DYNC-11022-000-0-12 DC11022-000-012
CW to incr fuel, act head pos 90° CCW from std
DYNC-11020, 24 Vdc DYNC-11022-000-0-24 DC11022-000-024
CW to incr fuel, act head pos 90° CW from std
DYNC-11020, 24 Vdc DYNC-11023-000-0-24 DC11023-000-024
CW to incr fuel, side-mounted actuator, act head pos 90° CW from std
DYNC-11020, 24 Vdc DYNC-11023-300-0-24 DC11023-300-024
Output shaft rotates 35°, CCW to incr fuel, std
head pos, 12 Vdc DYNC-11024-000-0-12 DC11024-000-012
Output shaft rotates 35°, CCW to incr fuel, std
head pos, 24 Vdc DYNC-11024-000-0-24 DC11024-000-024
CCW to incr fuel, std head pos, side-mounted
actuator, 12 Vdc DYNC-11024-300-0-12 DC11024-300-012
CCW to incr fuel, std head pos, side-mounted
actuator, 24 Vdc DYNC-11024-300-0-24 DC11024-300-024
CCW to incr fuel, act head pos 90° CW from std
DYNC-11024, 24 Vdc DYNC-11025-000-0-24 DC11025-000-024
CCW to incr fuel, side-mounted actuator, act head pos 180° from std
DYNC-11024, 24 Vdc DYNC-11026-300-0-24 DC11026-300-024
DYNA 8200 (work capacity 2.1 ft-lb, output shaft rotates 45 degrees, dual output shafts)
Std head rotation, 12 Vdc DYNC-12000-000-0-12 DC12000-000-012
Std head rotation, 24 Vdc DYNC-12000-000-0-24 DC12000-000-024
Hd rot 180° from std, 12 Vdc DYNC-12001-000-0-12 DC12001-000-012
Hd rot 180° from std, 24 Vdc DYNC-12001-000-0-24 DC12001-000-024
Hd rot 90° CCW from std, 12 Vdc DYNC-12002-000-0-12 DC12002-000-012
Plus 4 (work capacity 4 ft-lb, contactless potentiometer feedback, output shaft rotates 45
degrees, 24 Vdc)
CW & CCW via through-shaft DYNC-14000-001-0-24 DC14000-001-024
Stanadyne (Stanadyne integrated governors for Stanadyne “D” series injection pumps)
Standard, 12 Vdc DYNC-70025-002-0-12 DC70025-002-012
Standard, 24 Vdc DYNC-70025-002-0-24 DC70025-002-024
Int gov sealed unit, 12 Vdc DYNC-70025-003-0-12 DC70025-003-012
Int gov sealed unit, 24 Vdc DYNC-70025-003-0-24 DC70025-003-024

APECS 0200R
12 Vdc SA-4928-12
24 Vdc SA-4928-24

10 Woodward
Manual 25182 Energy Controls Product Information
Old Part WISE Part
Number Number

3. APECS™ Controllers
APECS 500 Controller (manually adjusted, computer calibrated)
APECS 500 SA-4492
APECS 2000 Controller (manually adjusted, PID controller)
APECS 2000 SA-4389
APECS 3000 Controller (computer calibrated)
APECS 3000 SA-4450
APECS 3100 SA-4451
APECS 3200 SA-4452
APECS 3400 SA-4471
APECS 4500 Controller (computer calibrated)
APECS 4500 SA-4489
APECS 4500 with CAN 8800-1006
APECS Calibration Tool & Kits (for controllers 2000, 3000, 4000, 4500, 5000)
For all series 500 controllers SA-5206
For all series 3000 controllers SA-4455
For all series 4000 controllers SA-4475
For all series 4500 & 5000 controllers SA-4488
Connector kit for all series 4000 controllers SA-4473
Connector kit for all series 4500 & 5000 cont. SA-4490
DPG 2100 Series (low-cost, digital programmable control w/ single gain potentiometer;
frequency range 1000 to 11000 Hz, 9 to 30 Vdc)
For all DYNA non position feedback actuators on either diesel or gas engine applications,
fully programmable DPG-2101-002
For DYNA 2000/2500 actuators on natural gas or gasoline engine applications,
overall gain adj only; works with all DYNA non-position feedback actuators;
diesel or gas engine applications DPG-2102
For DYNC-60010/60020 gas valves (Phase II gas valves),
overall gain adj only DPG-2103
Replaces DYN1-1078x Stanadyne
series controls DPG-2104
For Power Flow integrated throttle body (Phase III gas valves),
overall gain adj only DPG-2105
12-pin Molex connector, ignition speed sensing, 2 speed set points, idle speed
& remote incr./decr. DPG-2145-002
12-pin Molex connector, magnetic pickup speed input, 2 speed set points, idle speed
& remote incr./decr. DPG-2155-002
DPG 2200 Series (digital programmable control, full PID configuration, start-up smoke
control, DYNA II compatibility, remote speed, idle/run, single-point torque limiting,
pushbutton selection, parameter setup & serial port interface; frequency range 1000 to
11000 Hz, 9 to 30 Vdc)
Replaces DYN1-1065x, DYN1-1068x, DYN1-1069x, DYN1-1075x,
DYN1-1079x series controls DPG-2201-002
Same as DPG 2201 except remote speed input
from potentiometer DPG-2223-002
DPG 2300 Series (for both diesel and gas engines used in off-highway mobile applications;
automatic food pedal calibration, adjustable acceleration/deceleration, adjustable
ramps, start-up routines, & torque limits)
13-wire Euro connector & MPU for
speed input DPG-2302-002
13-wire Euro connector & ignition for
speed input DPG-2345-002
Same as DPG 2223-001 except tuned for
Cummins EFC valve DPG-2401-002

Woodward 11
Energy Controls Product Information Manual 25182
Old Part WISE Part
Number Number
Actuator Mounted Controller (engine rpm/speed controller for use with +1, +4, +6, +8/16
actuators, 24 Vdc)
Pickup signal frequency operating range at maximum engine
rpm 2500 to 5000 Hz DYN1-10004-002-0-24 8270-1059
Pickup signal frequency operating range at maximum engine
rpm 5000 to 9500 Hz DYN1-10006-002-0-24 8270-1068
Panel Mounted Controller (engine rpm/speed controller for use with +1, +4, +6, +8/16
actuators, 24 Vdc; basic circuit same as actuator mounted controller)
Pickup signal frequency operating range at maximum engine rpm 2500 to 5000 Hz,
CE Rated, 12 Vdc DYN1-10504-004-0-12 8270-1078
Pickup signal frequency operating range at maximum engine rpm 2500 to 5000 Hz,
CE Rated, 24 Vdc DYN1-10504-004-0-24 8270-1060
Pickup signal frequency operating range at maximum engine rpm 5000 to 9500 Hz,
CE Rated, 24 Vdc DYN1-10504-004-0-24 8270-1082
Panel Mounted Controller/DYNA 8000/8200/8400 (engine rpm/speed controller used with
DYNA 8000, 8200, & 8400 actuators; adjustment for GAIN, INTEGRAL, DERIVATIVE, &
DROOP; can be used with ILS, load pulse, auto synch, etc)
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc, CE Rated DYN1-10654-000-0-12 8270-1021
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
24 Vdc, CE Rated DYN1-10654-000-0-24 8270-1004
Replaced by DPG-2201-001 or DPG-2223-001.
DYN1-10654-001-0-24 8270-1072
Panel Mounted Controller/DYNA 2000/2500 (for small linear actuators)
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc DYN1-10704-000-0-12 8270-1008
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc DYN1-10704-000-0-24 8270-1050
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc, CE Rated DYN1-10704-002-0-12 8270-1048
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc, CE Rated DYN1-10704-002-0-24 8270-1055
Pickup frequency operating range at maximum engine rpm 5000 to 9500 Hz,
12 Vdc DYN1-10716-000-0-12 DI10716-000-012
Pickup frequency operating range at maximum engine rpm 5000 to 9500 Hz,
12 Vdc DYN1-10716-000-0-24 8270-1087
PC Board Controller/DYNA 2000/2500 (linear actuator w/ low gain circuit for cold engine
starting; gas engine applications, no enclosure, 12 Vdc)
Pickup frequency operating range at maximum engine
rpm 2500 to 5000 Hz DYN1-10744-000-0-12 8270-1027
Panel Mounted Controller/DYNA 2000/2500 (can be used w/ ILS, load pulse, auto
synchronizer, etc)
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 12 Vdc DYN1-10754-000-0-12 8270-1015
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 24 Vdc DYN1-10754-000-0-24 8270-1038
Pickup frequency operating range at maximum engine rpm
5000 to 9500 Hz, 12 Vdc DYN1-10756-000-0-12 8270-1051
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz, CE Rated,
suggested replacement DPG-2201-001 or DPG-2223-001
DYN1-10754-001-0-12 8270-1018
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz, CE Rated,
suggested replacement DPG-2201-001 or DPG-2223-001
DYN1-10754-001-0-24 8270-1036

12 Woodward
Manual 25182 Energy Controls Product Information
Old Part WISE Part
Number Number
Panel Mounted Controller/Stanadyne “D” Series ()
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 12 Vdc DYN1-10784-000-0-12 8270-1058
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 24 Vdc DYN1-10784-000-0-24 8270-1074
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz, CE Rated,
suggested replacement DPG-2104 or DPG-2101-001
12 Vdc DYN1-10784-003-0-12 8270-1035
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz, CE Rated,
suggested replacement DPG-2104 or DPG-2101-001
24 Vdc DYN1-10784-003-0-24 8270-1075
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 12 Vdc DYN1-10794-000-0-12 8270-1013
Pickup frequency operating range at maximum engine rpm
2500 to 5000 Hz, 24 Vdc DYN1-10794-000-0-24 8270-1014
Pickup frequency operating range at maximum engine rpm 2500 to 5000 Hz,
12 Vdc, CE Rated DYN1-10794-002-0-012 8270-1033

4. APECS™ Speed Switches and Sensors


EPS 1000 Engine Protection System
EPS 100 Module SA-4478
EPS 100 Calibration Tool Kit SA-4479
DSS-2 Electronic Speed Switch
DSS-2 Digital Speed Switch, 2-channel 8800-1001
Magnetic Pickup SAE (5/8-18 UNF-2A)
2-1/8” (54 mm) insertion depth DYNT-10100
3-5/8” (92 mm) insertion depth DYNT-10200
3/4" (19 mm) insertion depth DYNT-10300
2-5/8” (66 mm) insertion depth DYNT-10400
5-5/8” (142 mm) insertion depth DYNT-10500
4-5/8” (117 mm) insertion depth DYNT-10600
5/8-18 UNF thread, 2 open leads SA-4424
5/8-18 UNF thrd, chisel tip, req. SA-1707-010 SA-2170
5/8-18 UNF thread, req. SA-1707-010 conn. SA-2171-A
Connector & shielded cable assy, 10 ft (3 m) SA-1707-010
Magnetic Pickup Metric (M16 x 1.5-6g)
2-1/8” (54 mm) insertion depth DYNT-11100
3-5/8” (92 mm) insertion depth DYNT-11200
3/4” (19 mm) insertion depth DYNT-11300
2-5/8” (66 mm) insertion depth DYNT-11400
5-5/8” (142 mm) insertion depth DYNT-11500
4-5/8” (117 mm) insertion depth DYNT-11600
Magnetic Pickup SAE (3/4-16, 2 unshielded 36” 16 AWG leads)
2.36” (59.94 mm) insertion depth DYNT-13200
3.30” (83.80 mm) insertion depth DYNT-13300
Magnetic Pickup UNF (3/4-16)
2 open leads SA-4423
Magnetic Pickup SAE High Output (5/8-18 UNF-2A)
4.0” (100.0 mm) insertion depth DYNT-15200
3.0” (75.0 mm) insertion depth DYNT-15400
5.0” (126.0 mm) insertion depth DYNT-15600
Magnetic Pickup SAE (3/8-24 UNF-2A, includes 6’ shielded harness, -.78” insertion)
0.78” insertion depth DYNT-17100
1.65” insertion depth DYNT-17150
2.05” insertion depth DYNT-17200 DT17200-001-000
3.78” insertion depth DYNT-17400
Magnetic Pickup SAE (3/4-16, includes 6’ shielded harness)
2.1” insertion depth DYNT-19200
Magnetic Pickup Fittings
3/4-16 to 5/8-18 DYNC-600-1 DC600-001-0-00
3/4-16 to 3/8-24 DYNC-600-2 DC600-002-0-00
5/8-18 to 3/8-24 DYNC-600-3 DC600-003-0-00

Woodward 13
Energy Controls Product Information Manual 25182
Old Part WISE Part
Number Number
Mini-Gen Signal Generator
MGJ Metric thread mount M22 E1 DIN 75 532 (includes drive shaft)
MGJ-1 Metric thread mount E1 DIN 75 532 (includes drive shaft)
MGO SAE tach mount (less drive shaft)
MGO-1 SAE mount 7/8-18 thread w/ 7/8-18 male feed-through (less drive shaft,ESS1)
MGW DDAD blower accessory drive (includes drive shaft)
MGY-1 DDAD accessory drive mount w/ SAE 7/8-18 male feed-through (less female output
drive shaft)
MGJ w/ M22 ADPT & 37 SA-2685-A
MGO #37 13.4” leads WPC PACCAR SA-4139
MGO #37 30” leads WEA conn. IH SA-3926
MGO Volvo 37 WPC SA-3648
MGO w/37 coil SA-2650-A
MGO w/37 coil & 0.187DR SA-2900-A
MGO w/ 2-pin conn./sleeve Bendix SA-2768-A
MGO w/ 8” leads & trailer conn. SA-2693-A
MGO #37 w/ 8” leads Volvo SA-3146-A
MGO #37 coil/dbl circ. SA-3176-D
MGO-1 30” leads conn. 0.187M.203F SA-3614
MGO-1 #37 SA-3937
MGO-1 #37 Eaton SA-3451
MGO-1 w/37 coil SA-2652-A
MGO-1 w/44 coil SA-2653-A
MGO-1 #44 wiring term. SA-2712-A
MGO-1 w/37 Freightliner SA-3391
MGO-1 37 WPC.203/M22 hub 30”CA SA-4103
MGW #37 LG RG SA-2772-A
Male Drive Shaft for SAE
0.104 square SA-2676
0.150 square SA-2633
0.152 round SA-2677
0.187 round SA-2678
0.193 square SA-2634
0.203 round SA-2679
Female Drive Shaft for SAE
0.104 square SA-2635
0.187 round SA-2637
0.203 round SA-2638

14 Woodward
Manual 25182 Energy Controls Product Information
Old Part WISE Part
Number Number
5. APECS™ Accessories
Remote Speed Controllers & Accessories
Lock for DYNS-10000 DYNS-1
Remote speed-setting pot (5 k, 10-turn) w/ 499 k resistor
& lock nut for pot DYNS-10000
Installation Kits
General purpose kit for DYNA-8000 governor,
no bracket in kit DYNK-10206
General purpose kit for DYNA-2000/2500
linear governor DYNK-10249
Detroit Diesel 16V71, 12V92, & 16V92, using
DYNA-8200 actuator DYNK-10355
Cummins “C” Bosch P3000 “A” pump DYNK-10393
Harness Magnetic Pickup (2-conductor shielded cable w/ 90-degree 2-pin connector)
Length 12’ (3.6 m) DYNK-44-2 DK44-002-0-00
Harness for Plus 1, Plus 4 (wiring for +1 or +4 actuator when using a panel-mounted
DYN1-10504 controller)
Length 12’ (3.6 m) DYNK-123-1 DK123-001-0-00
Connectors (mating electrical connectors, with cable clamp)
Straight, mates w/ DYN1 control box DYNZ-46-01 DZ46-001-0-00
90 degrees, mates w/ DYN1 control box DYNZ-46-02 DZ46-002-0-00
Straight, mates with MPU DYNZ-46-13 DZ46-013-0-00
90 degrees, mates with MPU DYNZ-46-14 DZ46-014-0-00
APECS Actuator Mounting Hardware Only (kits are boxed, not assembled)
Cummins C w/ Bosch A, MW, or P fuel pump and RSV governor; recommended actuator
is SA-4506 w/ SA-4684 (S1 spring); Cummins bracket must be
purchased from Cummins SA-4598
Kubota V2203-E; recommended actuator is SA-4502
w/ SA-4684 (S1 spring) SA-4457
APECS Actuator Accessories, Linkage (kits are bagged, not assembled)
Long linkage kit, center to center 3.3 to 7.9” SA-4661
Short linkage kit, center to center 2.2 to 2.6” SA-4742
Clevis, fits actuators w/ 1/4-28 or M6 threads
to rod ends below SA-4599
Spherical rod end, female, 1/4-28 SA-4619
Spherical rod end, male, 1/4-28 SA-4600
Threaded rod, 1/4-28 or M6 by 6” SA-4602

Woodward 15
Energy Controls Product Information Manual 25182

3—Electronic Controls
Part
Number
1. 2301A Controls
SPEED CONTROL (DIESEL OR GAS ENGINES)
2301A Speed Control 10–40 Vdc (Forward Acting) 9907-014
2301A Speed Control 10–40 Vdc (Reverse Acting) 9907-016

SPEED CONTROLS WITH REMOTE SPEED SETTING INPUT


2301A Speed Control with 4–20 mA input, 10–40 Vdc,
(Forward Acting) 9905-144
2301A Speed Control with 4–20 mA input, 10–40 Vdc,
(Reverse Acting) 9905-146
2301A Speed Control with 4–20 mA input, 90–150 Vdc,
88–132 Vac (Forward Acting) 9905-145
2301A Speed Control with 1–5 Vdc input, 10–40 Vdc
(Forward Acting) 9905-148

LOAD SHARING AND SPEED CONTROL (DIESEL OR GAS ENGINES)


2301A 20–40 Vdc (Forward Acting) 9907-018
2301A 20–40 Vdc (Reverse Acting) 9907-019

2. 2301E Electronic Load Sharing and Speed Controls


2301E – Engine LSSC, 24 Vdc Input, Ordinary Locations 8273-1011
2301E – Engine LSSC, 24 Vdc Input, Hazardous Locations 8273-1012

3. 2300E Electronic Load Sharing and Speed Controls


2300E – Hardware Only, Ordinary Locations 8273-1017
2300E – Hardware Only, Hazardous Locations 8273-1018

4. 723 Controls
DIGITAL SPEED CONTROL W/ LOAD SHARING
723 Speed Control/Power Generation
Low Voltage, DSLC load sharing 9907-031
High Voltage, DSLC load sharing 9907-032
Low Voltage, DSLC load sharing, torsional filter 9907-033
High Voltage, DSLC load sharing, torsional filter 9907-034
Low Voltage, DSLC/MSLC Gateway 8280-206
High Voltage, DSLC/MSLC Gateway 8280-207

723 Speed Control/Marine


Low Voltage, PG replacement 8280-219
This control controls speed and load of medium and high speed diesels in dual-engine marine
applications requiring mechanical load sharing.

*Contact your regional Distributor for current pricing and delivery information.

16 Woodward
Manual 25182 Energy Controls Product Information
Part
Number
5. 723PLUS Controls
723PLUS Control/Power Generation:
DSLC load sharing, high voltage/low speed 8280-467
DSLC load sharing, low voltage 8280-412
DSLC load sharing, high voltage 8280-413
Analog load sharing, low voltage 8280-414
Analog load sharing, high voltage 8280-415
Analog load sharing, low voltage/low speed 8280-480
Analog load sharing, high voltage/low speed 8280-481
DSLC/MSLC Gateway w/ CMNDS, low voltage 8280-416
DSLC/MSLC Gateway w/ CMNDS, high voltage 8280-417

723PLUS Control/Marine:
Single engine marine propulsion, low voltage/low speed 8280-418
Single engine marine propulsion, low voltage 8280-419
Dual engine marine load sharing, low voltage 8280-423

723PLUS Control/Industrial:
Variable speed/process control, low voltage 8280-464
Variable speed control, low voltage 8280-410

723PLUS Position Control:


20–160 mA actuator 8262-092

Handheld Programmer for 723PLUS 9907-205

6. 828 Control (723PLUS) Hardware Platform for Distributors


828 Low Voltage, Hardware Only 9907-247
828 High Voltage, Hardware Only 9907-248

7. Custom Control Platforms


AtlasSC 8273-040
AtlasSC - 1 Analog I/O Module 8273-041
AtlasSC - PowerSense 8273-042
AtlasSC - 1 Analog I/O Module, PowerSense 8273-043
Atlas-II 8273-584
Atlas-II - PowerSense 8273-586
Atlas-II - 1 Analog I/O Module 8273-565
Atlas-II - 1 Analog I/O Module, Profibus 8273-570
Atlas-II - 1 Analog I/O Module, DLE 8273-553
Atlas-II - 1 Analog I/O Module, PowerSense 8273-556
Atlas-II - 2 Analog I/O Modules 8273-571
Atlas-II - 2 Analog I/O Modules, Profibus 8273-552
Atlas-II - 2 Analog I/O Modules, Power Sense 8273-557
Atlas-II - 2 Analog I/O Modules, Power Sense, Profibus 8273-562
Atlas-II - 3 Analog I/O Modules 8273-555
Atlas-II - 3 Analog I/O Modules, Profibus 8273-560

Optional Atlas Accessories


AtlasSC or AtlasPC Relay Kit – 12 channel w/ cable 8928-459

Flex500 Controls 
Flex500 - Panel Mount, LVDC, OCP 8200-1340
Flex500 - Panel Mount, HVAC/DC, OCP 8200-1341
Flex500 - Panel Mount, LVDC, Zone-2, OCP 8200-XXXX

Woodward 17
Energy Controls Product Information Manual 25182

8. Engine System Custom Controls (733, 766, In-Pulse™ 2, ECM3)


733 Custom Control 8237-1177
766 Custom Control 8237-1179
In-Pulse 2 (110 V) 8237-1178
In-Pulse 2 (110 V) Universal Multipoint Driver (pattern #2) 8280-1121
In-Pulse 2 (110 V) Universal Multipoint Driver (pattern #3) 8280-1122
In-Pulse 2 (24 V) 8237-1180
Certification Adder
ECM3 8402-319
ECM3 Universal Multipoint Driver (pattern #2) 8280-1119
ECM3 Universal Multipoint Driver (pattern #3) 8280-1120

Auxiliaries for Marine Listing:


Filter 5466-1026
Bracket Kit 8928-7225
Connector 8928-7229

18 Woodward
Manual 25182 Energy Controls Product Information

4—Turbine Controls and Associated Devices


Part
Number
1. 2301E-ST Steam Turbine Controls
2301E-ST – Steam Turbine Control 8273-1013
2301E-ST – Steam Turbine Control, CSA Hazardous Loc 8273-1014

2. Peak® 150 Steam Turbine Controls


110 Vac/125 Vdc/NEMA 4/ without Modbus 9905-858
110 Vac/125 Vdc/NEMA 4X/ without Modbus 9905-864
110 Vac/125 Vdc/NEMA 4/ with Modbus 9905-861
110 Vac/125 Vdc/NEMA 4X/ with Modbus 9905-867
24 Vdc/NEMA 4/ without Modbus 9905-857
24 Vdc/NEMA 4X/ without Modbus 9905-863
24 Vdc/NEMA 4/ with Modbus 9905-860
24 Vdc/NEMA 4X/ with Modbus 9905-866

Hand Held Programmer 9907-205


Panel Mount Kit 8923-248

3. 505 Steam Turbine Controls


505 - LVDC, Ordinary Location 8200-1300  
505 - HVAC/DC, Ordinary Location 8200-1301
505 - LVDC, Zone-2 Hazardous Location 8200-1302

505-XT - LVDC, Ordinary Location 8200-1310 (To be released Nov. 2015)


505-XT - HVAC/DC, Ordinary Location 8200-1311 (To be released Nov. 2015)
505-XT - LVDC, Zone-2 Hazardous Location 8200-1312 (To be released Nov. 2015)

505-Enhanced flush mount, HVAC 9907-1181


505-Enhanced flush mount, AC/DC 9907-1182
505-Enhanced flush mount, LVDC 9907-1183
505 Marine Certified 8923-1704

RemoteView - Software License 8928-5311


Old 505 to New 505 Retrofit Wiring Kit 5404-1801
Vibration Sensor - 4-20mA Accelerometer, 16' cable 8928-7482
Vibration Sensors - 4-20mA Proximity SEC of America

505CC-2 Compressor or ITCC Controller


505CC-2 Controller, Atlas-II, 18-32 Vdc 8301-1258
505CC-2 Configuration Support (site/application review) xxxx-xxxx
Includes the following:
 3 days of engineering support (at site or at Woodward)
 the creation of a site-specific configuration file ready to be uploaded into the control
NOTES: Travel & Living expenses, if required, are not included.
Customer must supply applicable turbine & compressor performance information.

Woodward 19
Energy Controls Product Information Manual 25182
Part
Number
4. 5009FT Steam Turbine Controls
5009FT w/ 2 24 VDC PS 8262-1068

5009FT w/ 2 120 V AC/DC PS 8262-1070


5009FT w/ 2 120 V AC/DC PS, Integ-Act 8262-1071
5009FT w/ 2 120 V AC/DC PS, CCT 8262-1049
5009FT w/ 2 120 V AC/DC PS, CCT, Integ-Act 8262-1050
5009FT w/ 2 120 V AC/DC PS, CCT, Extra Analog I/O 8262-1051
5009FT w/ 2 120 V AC/DC PS, CCT, Integ-Act, Extra Analog I/O 8262-1052
5009FT Cabinet, w/ 2 120 V AC/DC PS, CCT 8262-1155
5009FT Cabinet, w/ 2 120 V AC/DC PS, CCT + Integ Act kit 8262-1156
5009FT Cabinet, w/ 2 120 V AC/DC PS, CCT + Extra Analog I/O 8262-1157

5009FT w/ 2 220 VAC PS 8262-1072


5009FT w/ 2 220 VAC PS, Integ-Act 8262-1073
5009FT w/ 2 220 VAC PS, CCT 8262-1053
5009FT w/ 2 220 VAC PS, CCT, Integ-Act 8262-1054
5009FT w/ 2 220 VAC PS, CCT, Extra Analog I/O 8262-1055
5009FT w/ 2 220 VAC PS, CCT, Integ-Act, Extra Analog I/O 8262-1056
5009FT Cabinet, w/ 2 220 VAC PS, CCT 8262-1159
5009FT Cabinet, w/ 2 220 VAC PS, CCT, Integ-Act 8262-1160
5009FT Cabinet, w/ 2 220 VAC PS, CCT, Extra Analog I/O 8262-1161
5009FT Cabinet, w/ 2 220 VAC PS, CCT, Integ-Act, Ex. Anal. I/O 8262-1162

5009FT Computer-Configuration & Commissioning Tool (CCT) 8269-1011


5009FT Computer-Optional IFix Operator Interface (HMI) 8269-1012

5. Standard MicroNet Turbine Control Kits


Standard MicroNet Turbine Kit, 8-Slot, 2 AC/DC Power Supplies 8262-1093
Standard MicroNet Turbine Kit, 8-Slot, 2 HVAC Power Supplies 8262-1094
Standard MicroNet Turbine Kit, 8-Slot, 2 LVDC Power Supplies 8262-1095
Global Steam Turbine Control Core Software License, GAP 5418-3915
For single valve & single extraction steam turbines only
Single application license only

Included within Standard MicroNet Turbine Control Kits


Chassis – MicroNet-Plus, 8-Slot (QTY = 1) 5453-829
Module – Power Supply (QTY = 2) Kit Dependent
Module – CPU5200 processor (QTY = 2) 5466-1245
Module – Analog Combo (QTY = 2) 5466-316
Module – Discrete Combo, (48) Inputs, (24) Outputs (QTY = 2) 5466-1158
FTM – Analog Combo (QTY = 2) 5501-371
FTM – Discrete Combo, (24) Inputs, (12) Outputs (QTY = 4) 5441-694
Cable – Analog, 10ft (QTY = 4) 5417-028
Cable – Discrete, 10ft (QTY = 4) 5417-173
Notes:
System I/O can be expanded with the use of Woodward’s RTCnet or LinkNet-HT distributed
I/O modules.
Cyber security can be enabled with purchase of license 8928-5222

6. GTC Gas Turbine Controls


GTC100–1 Shaft GT, Dual Fuel 8262-1003
GTC100–1 Shaft GT, Dual Fuel, PwrSns 8262-1001
GTC200–2 Shaft GT, Dual Fuel, 1-Analog Module 8262-1002
GTC200–2 Shaft GT, Dual Fuel, 1-Analog Module, PwrSns 8262-1022
GTC250A–2 Shaft Aero, Dual Fuel, Atlas-II, w/ Profibus 8262-1031
GTC250A-FC – 2 Shaft Aero Type Gas Turbine Fuel Control 8262-1036

7. Servo Position Controllers (replace Digital Remote Final Drivers)


SPC - Configurable Servo/Actuator Driver, Marine Certified 8200-226
Optional Mounting Bracket – Vertical 8928-7334  

20 Woodward
Manual 25182 Energy Controls Product Information
Part
Number
8. ProTech® Overspeed Protection Devices
ProTech-SX
ProTech-SX - Panel Mount, HV/LV 8237-1242
ProTech-SX - Panel Mount, HV/HV 8237-1243

ProTech-GII
ProTech-GII - Bulkhead Mount, HV/LV, Ind relay 8237-1594
ProTech-GII - Bulkhead Mount, HV/HV, Ind relay 8237-1595
ProTech-GII - Bulkhead Mount, HV/LV, voted relays 8237-1596
ProTech-GII - Bulkhead Mount, HV/HV, voted relays 8237-1597
ProTech-GII - Panel Mount, HV/LV, Ind relay 8237-1598
ProTech-GII - Panel Mount, HV/HV, Ind relay 8237-1599
ProTech-GII - Panel Mount, HV/LV, voted relays 8237-1600
ProTech-GII - Panel Mount, HV/HV, voted relays 8237-1601

ProTechTPS
ProTechTPS - Bulkhead Mount, HV/LV, Ind relay 8237-1602
ProTechTPS - Bulkhead Mount, HV/HV, Ind relay 8237-1603
ProTechTPS - Bulkhead Mount, HV/LV, voted relays 8237-1604
ProTechTPS - Bulkhead Mount, HV/HV, voted relays 8237-1605
ProTechTPS - Panel Mount, HV/LV, Ind relay 8237-1606
ProTechTPS - Panel Mount, HV/HV, Ind relay 8237-1607
ProTechTPS - Panel Mount, HV/LV, voted relays 8237-1608
ProTechTPS - Panel Mount, HV/HV, voted relays 8237-1609

MicroNet Safety Module


MicroNet Safety Module - Bulkhead Mount, HV/LV, Ind relay 8237-1492
MicroNet Safety Module - Bulkhead Mount, HV/HV, Ind relay 8237-1493
MicroNet Safety Module - Bulkhead Mount, HV/LV, voted relays 8237-1496
MicroNet Safety Module - Bulkhead Mount, HV/HV, voted relays 8237-1497
MicroNet Safety Module - Panel Mount, HV/LV, Ind relay 8237-1494
MicroNet Safety Module - Panel Mount, HV/HV, Ind relay 8237-1495
MicroNet Safety Module - Panel Mount, HV/LV, voted relays 8237-1498
MicroNet Safety Module - Panel Mount, HV/HV, voted relays 8237-1499

Conversion Kits
Old ProTech-GII models to new Input Voting ProTech-GII 8928-1308
Old ProTechTPS models to new Input Voting ProTechTPS 8928-1309
Old MicroNet Safety Module models to new Input Voting models 8928-1310

Woodward 21
Energy Controls Product Information Manual 25182

9. MicroNet™ System Modules, Cables, & Accessories


Field  Cable 
Par 
Description  Notes  Termination  Selection 
Number 
Modules  Table 
Chassis         
Micronet Plus 8 Slot Chassis  5453‐829       
Micronet Plus 14 Slot Chassis  5453‐759       
MicroNet TMR Chassis  5453‐279       
Connect to Main chassis using 5416‐977 
MicroNet TMR Power Supply Chassis  5453‐277  ribbon cable and redundant 5417‐293     
power supply interconnect cable. 
Blank Module ‐ 1” blank module to divert cooling  3799‐301       
          
Power Supplies         
MicroNet Plus PS ‐ 24 Vdc Input  5466‐1000       
MicroNet Plus PS ‐ 110Vac/125Vdc Input  5466‐1001       
MicroNet Plus PS ‐ 220Vac Input  5466‐1002       
          
MicroNet TMR PS ‐ 24 Vdc Input  5501‐370       
MicroNet TMR PS ‐ 120 Vac/Vdc Input  5501‐380       
MicroNet TMR PS 0 220 Vac Input  5501‐381       
MicroNet TMR Kernel PS  5466‐1049  Only used with CPU5200     
          
CPU Modules         
Use with 5466‐1036 RTN Expansion Rack 
5200CPU MicroNet Plus  5466‐1035     
Module 
Use with 5466‐1046 RTN Expansion Rack 
Module. 
5200CPU MicroNet Plus (Cyber‐Security)  5466‐1045     
Requires license 8928‐5222 to enable 
cyber security. 
Use with 5466‐1246 RTN Expansion Rack 
5200CPU MicroNet Plus – Secure Application  5466‐1141     
Module 
Use with 5466‐1146 RTN Expansion Rack 
Module. 
5200CPU MicroNet Plus (Cyber‐Security) LICENSED  5466‐1145     
Includes cyber security license  
8928‐5222. 
Use with 5466‐1246 RTN Expansion Rack 
5200CPU MicroNet Plus –Enhanced Performance  5466‐1245     
Module 
Use with 5466‐1036 RTN Expansion Rack 
5200CPU MicroNet TMR  5466‐1047     
Module, requires 5466‐1049 Kernel P.S. 
          
Communication Modules         
RTN to CAN Gateway (bulkhead mount Atlas based)  8200‐1250  CAN to RTN Gatway Interface     
Real Time Network XCVR ‐ Use with 
RTN Module ‐ Expansion Rack XCVR  5466‐1036     
5466‐1035 or 5466‐1047 style of CPU 
Real Time Network XCVR (Cyber‐security) 
Remote RTN (MicroNet Plus) (Cyber‐Security)  5466‐1046     
‐ Use with 5466‐1045 style of CPU 
Remote RTN (MicroNet Plus) (Cyber‐Security)  Real Time Network XCVR (Cyber‐security) 
5466‐1146     
LICENSED  ‐ Use with 5466‐1145 style of CPU 
Real Time Network XCVR (Cyber‐security) 
Remote RTN (MicroNet Plus) – Secure Application  5466‐1246     
‐ Use with 5466‐1141 & 5466‐1245 CPUs 
SIO Module ‐ , 4 Channel, two RS‐232, two  Connectors use DB‐9 screw post 
5501‐471    Table I 
configurable (RS‐232, RS‐422, RS‐485), Screw posts  connectors 
SIO Module ‐ , 4 Channel, two RS‐232, two  Connectors use DB‐9 with slide lock 
5466‐348    Table I 
configurable (RS‐232, RS‐422, RS‐485), Slide Locks  posts 
LinkNet Controller Module ‐ 4 Channel  5466‐031      Table G 
          

22 Woodward
Manual 25182 Energy Controls Product Information

Input Modules         
24 Vdc w/o LEDs, common bus, Requires 
5437‐419, 
Discrete Input ‐ 48 channel, 24 VDC  5464‐643  2 FTM's & 1 cable to each FTM. Total of 2  Table K 
5437‐687 
cables. 
          
Speed Sensor ‐ 4 channel, MPU  5464‐658    5437‐523  Table J 
Same as 5464‐658 except has isolated 
Speed Sensor ‐ 4 channel, MPU, Isolated  5466‐404  5437‐523  Table J 
power for LOCOP 
Speed Sensor ‐ 4 channel, Proximity Probe  5464‐659    5437‐523  Table J 
Speed Sensor ‐ 4 channel, MPU / Eddy Probe  5464‐834    5437‐523  Table J 
Speed Sensor ‐ 4 channel, MPU / Proximity Probe  5464‐850    5437‐523  Table J 
          
4‐20 mA ‐ 8 channel, Isolated  5464‐334    5437‐523  Table J 
0‐10 Vdc ‐ 8 channel, Isolated  5464‐335    5437‐523  Table J 
Thermocouple ‐ 8 channel, Fail Low, Isolated  5464‐332    5437‐524  Table J 
Thermocouple ‐ 8 channel, Fail High, Isolated  5464‐333    5437‐524  Table J 
RTD ‐ 8 channel, 10 Ohm, Semi‐Isolated  5464‐336    5437‐523  Table J 
RTD ‐ 8 channel, 100 Ohm, Semi‐Isolated  5464‐337    5437‐523  Table J 
RTD ‐ 8 channel, 100 Ohm, Semi‐Isolated, High Temp  5464‐340    5437‐523  Table J 
RTD ‐ 8 channel, 200 Ohm, Semi‐Isolated  5464‐338    5437‐523  Table J 
RTD ‐ 8 channel, 500 Ohm, Semi‐Isolated  5464‐339    5437‐523  Table J 
High Density, Voltage Input Module,  5503‐282 
4‐20/TC/RTD ‐ 34 channel  5503‐279  Table M 
Requires 2 FTMs  (2) 
Pressure Interface ‐ 2 Channel (4 
5466‐326  See Pressure Transducer Assemblies  5437‐523  Table J 
transducers/channel) 
          
Output Modules         
5441‐413 or 
Discrete Output Driver‐ 64 channel  5464‐654    Table K 
1751‐6091 
          
5437‐523 or 
4‐20 mA ‐ 8 channel  5464‐648    5501‐427  Table J 
(TMR) 
5437‐523 or 
0‐1 mA ‐ 8 channel  5464‐649    5501‐427  Table J 
(TMR) 
5437‐523 or 
0‐5 Vdc ‐ 8 channel  5464‐650    5501‐427  Table J 
(TMR) 
5437‐523 or 
0‐10 Vdc ‐ 8 channel  5464‐652    5501‐427  Table J 
(TMR) 
          
Actuator Driver ‐ 2 channel +/‐ 12.25 mA Integrating 
5501‐428  Bi‐Polar( + )Actuator Driver  5437‐672  Table K 
or Proportional (software selectable) Outputs 
Actuator Driver ‐ 2 channel +/‐ 30 mA Integrating or 
5501‐429  Bi‐Polar( + )Actuator Driver  5437‐672  Table K 
Proportional (software selectable) Outputs 
Actuator Driver ‐ 2 channel +/‐ 60 mA Integrating or 
5501‐430  Bi‐Polar( + )Actuator Driver  5437‐672  Table K 
Proportional (software selectable) Outputs 
Actuator Driver ‐ 2 channel +/‐ 120 mA Integrating or 
5501‐431  Bi‐Polar( + )Actuator Driver  5437‐672  Table K 
Proportional (software selectable) Outputs 
Actuator Driver ‐ 2 channel +/‐ 245 mA Integrating or 
5501‐432  Bi‐Polar( + )Actuator Driver  5437‐672  Table K 
Proportional (software selectable) Outputs 
Actuator Driver ‐ 4 channel 0‐200 mA , Proportional 
5464‐544  Uni‐Polar( + )Actuator Driver  5437‐525  Table A 
Only Output 
Actuator Driver ‐ 4 channel 4‐20 mA , Proportional 
5464‐545  Uni‐Polar( + )Actuator Driver  5437‐525  Table A 
Only Output 
Uses screw post connectors, Use w/ LQ 
Real Time SIO ‐ Connects to GS/LQ & EM Drivers  5503‐267  Driver & EM Digital ‐ Multidrop is not     
allowed with this module 
Woodward 23
Energy Controls Product Information Manual 25182

Input & Output Modules         
Simplex Combo I/O ‐ 4 MPU's, 8 4‐20 mA Inputs, 4 4‐ 5501‐371 
5466‐316    Table J 
20 mA Outputs, 2 Prop. Actuator Outputs  (2) 
Digital I/O, SW Compatible only in coder  5501‐325 
Table M
5.0x and up, Simplex FTM relay drivers  (HV) (1) or 
Simplex Discrete I/O ‐ 48 Inputs / 24 Outputs  5466‐1050   (2 
5441‐693, 5441‐694 FTMs also are  5501‐367 
cables) 
options  (LV) (1) 
Digital I/O, Use as a spare only, Backward 
5501‐325 
compatible with older systems, SW  Table M
Simplex Discrete I/O ‐ 48 Inputs / 24 Outputs ‐2  (HV) (1) or 
5466‐1158  Compatible only in coder 4.06, 5.04,   (2 
(spare)  5501‐367 
6.00, Simplex FTM relay drivers 5441‐ cables) 
(LV) (1) 
693, 5441‐694 FTMs also are options 
5501‐376 
Table M
Simplex Analog I/O ‐ (24) 4‐20 mA Inputs, (8) 4‐20  (2) or TMR 
5466‐315     (2 
mA Outputs  5501‐372 
cables) 
(2) 
5501‐376 
Table M
Simplex Analog I/O ‐ (24) 4‐20 mA Inputs, (8) 4‐20  Special for LM's ‐ Reduced filtering on  (2) or TMR 
5466‐332   (2 
mA Outputs ‐ Reduced filtering  chan 23/24 for Stall Detection  5501‐372 
cables) 
(2) 
Same as ‐332 only configured for 
5441‐695 
DataForth I/O, All inputs configured for  Table M
Simplex DataForth Analog I/O ‐ (24) 4‐20 mA Inputs,  (2) TMR 
5466‐425  voltage inputs. Both FTM's manufactured   (2 
(8) 4‐20 mA Outputs  5441‐697 
by DataForth, 9097‐601 DataForth  cables) 
(2) 
module TAB 
          
TMR Combo I/O ‐ (4) MPU's, (8) 0‐5 Volt Inputs, (4)  5501‐365 
5466‐253    Table J 
4‐20 mA Outputs, (2) Prop. Actuator Outputs  (2) 
TMR Combo I/O ‐ (3) MPU, (1) Prox, (8) 0‐5 Volt 
5501‐365 
Inputs, (4) 4‐20 mA Outputs, (2) Prop. Actuator  5466‐1070    Table J 
(2) 
Outputs 
Table M
With 4 FTMs and 3 MicroNet cards,  5453‐276 
TMR Discrete I/O ‐ 48 Inputs / 24 Outputs  5466‐1051   (2 
system I/O is 24 DI and 12 DO  (4) 
cables) 
Digital I/O, Use as a spare only, Backward 
compatible with older systems, SW  Table M
5453‐276 
TMR Discrete I/O ‐ 48 Inputs / 24 Outputs (spare)  5466‐1156  Compatible only in coder 4.06, 5.04,   (2 
(4) 
6.00, With 4 FTMs and 3 MicroNet cards,  cables) 
system I/O is 24 DI and 12 DO 
Table M
TMR Analog I/O ‐ (24) 4‐20 mA Inputs, (8) 4‐20 mA  All input channels are 0‐5v input with  5501‐372 
5466‐257   (2 
Outputs  circuit resistors on FTM  (2) 
cables) 
          
Special Function Modules         
Dual Solenoid Monitor  5466‐272  Cable 5417‐296 used in 9971‐1083  5437‐523  Table J 
Overspeed Trip Module ‐ trip @ 5478 Hz  5501‐473    5437‐523  Table A 
Overspeed Trip Module ‐ trip @ 5408 & 6160 Hz  5501‐476    5437‐523  Table A 
Overspeed Trip Module ‐ trip @ 5408 Hz  5501‐477    5437‐523  Table A 
Overspeed Trip Module ‐ trip @ 5404 Hz  5501‐478    5437‐523  Table A 
Overspeed Trip Module ‐ trip @ 6160 Hz  5501‐479    5437‐523  Table A 
          

24 Woodward
Manual 25182 Energy Controls Product Information

Relay FTMs         
Discrete Output Relay ‐ 32 channel, 10 Amp at 28 
5441‐413  1 Form 'C' contact per relay    Table K 
VDC 
Discrete Output Relay ‐ 16 channel, 10 Amp at 28  Pruchased from Phoenix Contact. No 
1751‐6091    Table K 
VDC  Surface Mount Components. 
Pruchased from Phoenix Contact. No 
Discrete I/O ‐ 24 Inputs /12 Relay Outputs  5441‐693    Table M 
Surface Mount Components. 
Simplex High Density Discrete Inputs, 
Discrete I/O ‐ 48 Inputs ‐ 125Vdc, 24 Discrete 
5501‐325  Discrete Outputs are routed from J1 & J2    Table M 
Outputs J1 & J2 to J3 cable connectors 
to J3 
Simplex High Density Discrete Inputs, 
Discrete I/O ‐ 48 Inputs ‐ 24Vdc, 24 Discrete Outputs 
5501‐367  Discrete Outputs are routed from J1 & J2    Table M 
J1 & J2 to J3 cable connectors 
to J3 
Used with 5009FT and TMR applications, 
TMR Discrete I/O ‐ 6 Inputs, 3 Relay Outputs  5453‐276    Table M 
Uses cable 5417‐019 between FTMs 
          
LINKnet HT Modules         
RTN Gateway ‐ 10 CAN ports  8200‐1250       
RTD Input ‐ 8 Channel  8200‐1200      Table R 
Thermocouple Input ‐ 8 Channel, Fail high  8200‐1201      Table R 
4‐20 mA ‐ 8 Inputs / 2 Outputs  8200‐1202      Table R 
4‐20 mA ‐ 8 Inputs / 2 Outputs, 24Vdc Loop Power  8200‐1203      Table R 
Discrete Input ‐ 16 Channel  8200‐1204      Table R 
Discrete Output ‐ 16 Channel  8200‐1205      Table R 
          
RTCnet Modules         
RTN Gateway ‐ 10 CAN ports  8200‐1250      Table R 
RTD Input ‐ 8 Channel  8200‐1100      Table R 
Thermocouple Input ‐ 8 Channel, Fail high  8200‐1101      Table R 
Thermocouple Input ‐ 8 Channel, Fail high, High 
8200‐1151  Use for Gas Turbine EGT Monitoring    Table R 
Accuracy 
4‐20 mA ‐ 8 Inputs / 2 Outputs  8200‐1102      Table R 
4‐20 mA ‐ 8 Inputs / 2 Outputs, 24Vdc Loop Power  8200‐1103      Table R 
Discrete Input ‐ 16 Channel  8200‐1104      Table R 
Discrete Output ‐ 16 Channel  8200‐1105      Table R 
Termination Resistor Kit  8923‐1889       
          
Dataforth I/O 
Thermocouple ‐ K‐Type  1784‐1028  Datforth PN: SCM7B47K‐1574  5441‐695   
Datforth PN: SCM7B34‐1459, European 
RTD ‐ 100 Ohm  1784‐655  5441‐695   
Curve 
4‐20 mA Input  1784‐659  Datforth PN: SCM7BPT‐1460  5441‐695   
0‐5 Vdc Input  1784‐657  Datforth PN: SCM7BPT  5441‐695   
          
Network Switches         
Hirshmann PN: RS2‐TX, Compatible with 
Ethernet ‐ 8 Port, RJ45 Connectors  1752‐423  CPU5200, Recommended for Expansion     
Racks 
Hirshmann PN: RS2‐4TX/1FX EEC, 
Compatible with CPU5200, 
Fiber Optic ‐ 5 Port  1711‐1069     
Recommended for Expansion Racks, 5 
port 
Hirshmann PN: RS2‐3TX/2FX, Compatible 
Fiber Optic ‐ 5 Port  1751‐6077     
with CPU5200 
          

Woodward 25
Energy Controls Product Information Manual 25182

MicroNet System Cables 
Table A ‐ NetCon Analog Cables         
6 feet, Black  5416‐346  Netcon style exposed braid     
8 feet, Black  5416‐347  Netcon style exposed braid     
10 feet, Black  5416‐348  Netcon style exposed braid     
12 feet, Black  5416‐349  Netcon style exposed braid     
14 feet, Black  5416‐350  Netcon style exposed braid     
16 feet, Black  5416‐351  Netcon style exposed braid     
18 feet, Black  5416‐352  Netcon style exposed braid     
20 feet, Black  5416‐353  Netcon style exposed braid     
22 feet, Black  5416‐354  Netcon style exposed braid     
26 feet, Black  5416‐355  Netcon style exposed braid     
40 feet, Black  5416‐751  Netcon style exposed braid     
          
Table B ‐ NetCon Discrete Cables         
3 feet, Gray  5416‐332       
6 feet, Gray  5416‐333       
8 feet, Gray  5416‐334       
10 feet, Gray  5416‐335       
12 feet, Gray  5416‐336       
14 feet, Gray  5416‐337       
16 feet, Gray  5416‐338       
18 feet, Gray  5416‐339       
20 feet, Gray  5416‐340       
22 feet, Gray  5416‐341       
24 feet, Gray  5416‐342       
26 feet, Gray  5416‐343       
40 feet, Gray  5416‐750       
          
Table C ‐ PS/2 keyboard/ Mouse  Inactivated       
          
Table D ‐ Transceiver Cables         
Not Compatible with CPU5200, Used 
10 feet, Metal Braid (Spare)  5415‐963  with old Simplex or TMR MicroNet     
systems 
Not Compatible with CPU5200, Used 
T‐Module (Spare)  5437‐059  with old Simplex or TMR MicroNet     
systems 
          
Table E ‐ Ethernet Cables  Inactivated       
          
Table F ‐ Ethernet Cat‐5 Cables         
1.5 feet  5417‐391       
3 feet  5417‐392       
7 feet  5417‐393       
10 feet  5417‐394       
15 feet  5417‐1243       
25 feet  5417‐396       
10 feet, crossover  5417‐414       
14 feet, crossover  5417‐415       
          
Table G ‐ LinkNet Cable         
Wire ‐ 2 CONDUCTOR 22AWG, LOW CAP  2008‐349       
          

26 Woodward
Manual 25182 Energy Controls Product Information

Table H ‐ MicroNet TMR Cables         
Used between Power Supply & Main 
PS Interconnect Cable, 40"  5417‐293     
Chassis 
Used between Power Supply & Main 
PS 50 pin Ribbon Cable, 6"  5416‐977     
Chassis 
Used between FTMs 5453‐276 as 
34 pin Ribbon Cable for Relay FTM interconnect. 6"  5417‐019     
interconnect cable 
          
Table I ‐ RS232 Serial Port Cables         
9 Pin DB ‐ Male to Female, Extension, 6 feet  5417‐411       
9 Pin DB ‐ Male to Female, Extension, 10 feet  5417‐412       
9 Pin DB ‐ Male to Female, Extension, 15 feet  5417‐413       
          
Table J ‐ Low Density Analog Cables         
3 feet, Black  5417‐296  MicroNet style‐‐ no exposed braid     
6 feet, Black  5417‐026  MicroNet style‐‐ no exposed braid     
8 feet, Black  5417‐027  MicroNet style‐‐ no exposed braid     
10 feet, Black  5417‐028  MicroNet style‐‐ no exposed braid     
12 feet, Black  5417‐029  MicroNet style‐‐ no exposed braid     
14 feet, Black  5417‐030  MicroNet style‐‐ no exposed braid     
16 feet, Black  5417‐031  MicroNet style‐‐ no exposed braid     
18 feet, Black  5417‐032  MicroNet style‐‐ no exposed braid     
20 feet, Black  5417‐033  MicroNet style‐‐ no exposed braid     
22 feet, Black  5417‐034  MicroNet style‐‐ no exposed braid     
26 feet, Black  5417‐035  MicroNet style‐‐ no exposed braid     
40 feet, Black  5417‐036  MicroNet style‐‐ no exposed braid     
          
Table K ‐ Low Density Discrete Cables         
3 feet, Gray  5417‐037       
6 feet, Gray  5417‐038       
8 feet, Gray  5417‐039       
10 feet, Gray  5417‐040       
12 feet, Gray  5417‐041       
14 feet, Gray  5417‐042       
16 feet, Gray  5417‐043       
18 feet, Gray  5417‐044       
20 feet, Gray  5417‐045       
22 feet, Gray  5417‐046       
24 feet, Gray  5417‐047       
26 feet, Gray  5417‐048       
30 feet, Gray  5417‐1108       
40 feet, Gray  5417‐049       
          
Table L ‐ VGA Video Ext. Cables         
15 Pin HD ‐ Male to Female, Extension, 6 feet  5417‐405       
15 Pin HD ‐ Male to Female, Extension, 10 feet  5417‐406       
15 Pin HD ‐ Male to Female, Extension, 15 feet  5417‐407       
15 Pin HD ‐ Male to Male, 6 feet  5417‐408       
15 Pin HD ‐ Male to Male, 10 feet  5417‐409       
15 Pin HD ‐ Male to Male, 15 feet  5417‐410       
          

Woodward 27
Energy Controls Product Information Manual 25182

Table M ‐ HD Analog/Discrete Cables         
6 feet, Gray  5417‐171       
8 feet, Gray  5417‐172       
10 feet, Gray  5417‐173       
12 feet, Gray  5417‐174       
14 feet, Gray  5417‐175       
16 feet, Gray  5417‐176       
18 feet, Gray  5417‐177       
20 feet, Gray  5417‐178       
          
Table N ‐ Fiber Optic Cables ST Type  Inactive       
          
Table P ‐ RS‐485 Cables for RTSIO  Inactive       
          
Table Q ‐ Fiber Optic Cables SC Type (MicroNet Plus 
       
‐ CPU and RTN) 
2 meter  5417‐1090       
3 meter  5417‐1091       
5 meter  5417‐1092       
10 meter  5417‐1093       
15 meter  5417‐1094       
30 meter  5417‐1095       
ST to SC Duplex Adapter  1751‐6079       
SC to SC Duplex Coupler  1751‐6080       
          
Table R ‐ CAN / DEVICENET Cables         
NETWORK TEE, 7/8' M/F BUS, F DROP  1635‐1463       
NETWORK TERMINATOR, MALE 121 OHM  1635‐1464       
NETWORK TERMINATOR, FEMALE 121 OHM  1635‐1465       
          
THICK TRUNK CABLE (0.5M)  5417‐1110  0.41 Diameter     
THICK TRUNK CABLE (1M)  5417‐1111  0.41 Diameter     
THICK TRUNK CABLE (2M)  5417‐1112  0.41 Diameter     
THICK TRUNK CABLE (3M)  5417‐1113  0.41 Diameter     
THICK TRUNK CABLE (4M)  5417‐1114  0.41 Diameter     
THICK TRUNK CABLE (6M)  5417‐1115  0.41 Diameter     
          
THICK DROP, 7/8' MALE TO PIGTAIL, (0.3M)  5417‐1116       
THICK DROP, 7/8' MALE TO PIGTAIL, (1M)  5417‐1117       
THICK DROP, 7/8' MALE TO PIGTAIL, (2M)  5417‐1118       
THICK DROP, 7/8' MALE TO PIGTAIL, (3M)  5417‐1119       
THICK DROP, 7/8" MALE TO PIGTAIL, (6M)  5417‐1281       
          
MICRONET DROP, M12 FEMALE TO 7/8' MALE, 
5417‐1120  0.28 Diameter     
(0.5M) 
MICRONET DROP, 7/8' MALE TO M12 FEMALE, (1M)  5417‐1127  0.28 Diameter     
MICRONET DROP, 7/8' MALE TO M12 FEMALE, (2M)  5417‐1128  0.28 Diameter     
MICRONET DROP, 7/8" MALE TO M12 FEMALE, (3M)  5417‐1245  0.28 Diameter     
          
MID DROP, 7/8' MALE TO PIGTAIL, (0.3M)  5417‐1141       
MID DROP, 7/8' MALE TO PIGTAIL, (1M)  5417‐1142       
MID DROP, 7/8' MALE TO PIGTAIL, (2M)  5417‐1143       
MID DROP, 7/8' MALE TO PIGTAIL, (3M)  5417‐1144       

28 Woodward
Manual 25182 Energy Controls Product Information

          
MID TRUNK CABLE (0.5M)  5417‐1145  0.33 Diameter     
MID TRUNK CABLE (1M)  5417‐1146  0.33 Diameter     
MID TRUNK CABLE (2M)  5417‐1147  0.33 Diameter     
MID TRUNK CABLE (3M)  5417‐1148  0.33 Diameter     
MID TRUNK CABLE (4M)  5417‐1149  0.33 Diameter     
MID TRUNK CABLE (6M)  5417‐1150  0.33 Diameter     

Woodward 29
Energy Controls Product Information Manual 25182
Part
Number
10.DVP Digital Valve Positioner
125V DVP Driver
IP30, Ethernet, TB Input, Circ Connector Output 8200-182
IP30, Ethernet, TB Input, TB Output 8200-183
IP30, Tb Input, TB Output 8200-186
IP30, Tb Input, Circ Connector Output 8200-188
IP30, Ethernet, TB Input, 4 Circ Connector Output 8200-189
IP30, Tb Input, 4 Circ Connector Output 8200-190
IP56, Ethernet, Tb Input, TB Output 8200-184
IP56, Ethernet, Conduit Input, Circ Connector Output 8200-185
IP56, Conduit Input, Circ Connector Output 8200-187
IP56, Conduit Input, Conduit Output 8200-504

24 Vdc DVP Driver


IP30, Ethernet, TB Input, TB Output 8200-505
IP30, TB Input, TB Output 8200-507
IP30, Ethernet, TB Input, Circ Connector Output 8200-509
IP30, TB Input, Circ Connector Output 8200-510
IP30, Ethernet, TB Input, 4 Circ Connector Output 8200-511
IP56, Ethernet, Conduit Input And Output 8200-506
IP56, Conduit Input And Output 8200-508
IP56, Conduit, Circ Connector Output 8200-513

DVP Cable
Cable Part Number
Configuration
200C Cable 125C Cable Heavy Flame
(DVP J1) - Motor Power, 5 Pin Straight-to-Straight Connector 5450-1096.xx 5450-1837.xx
(DVP J1) - Motor Power, 5 Pin, Straight-to-Right Angle Connectors 5450-1819.xx 5450-1836.xx N/A
5450-1835.xx
(DVP J1) - Motor Power, 5 Pin, Flying Lead-to- Straight Connector 5450-1818.xx 5450-1701.xx
5450-1460.xx
(DVP J1) - Motor Power, 5 Pin, Flying Lead -to- Right Angle Connector 5450-1817.xx 5450-1834.xx 5450-1694.xx
(DVP J2) - Feedback1,Motor Resolver, 10 Pins Straight-to-Straight
5450-1806.xx 5450-1822.xx N/A
Connectors
(DVP J2) - Feedback1, Motor Resolver, 10 Pin, Straight-to-Right Angle 5450-1824.xx
5450-1095.xx N/A
Connectors 5450-1445.xx
(DVP J2) - Feedback1, Motor Resolver, 10 Pin, Flying Lead-to-Straight
5450-1808.xx 5450-1821.xx 5450-1696.xx
Connectors
(DVP J2) - Feedback1, Motor Resolver, 10 Pin Flying Lead-to-90 5450-1823.xx
5450-1807.xx 5450-1703.xx
Degree Connector 5450-1462.xx
(DVP J3) - Feedback2 Stem Resolver & ID, 14 Pin,Straight-to-Straight 5450-1828.xx
5450-1094.xx N/A
Connector 5450-1446.xx
(DVP J3) - Feedback2, Stem Resolver & ID, 14 Pin,Straight-to-90 Deg.
5450-1809.xx 5450-1827.xx N/A
Connector
(DVP J3) - Feedback2, Stem Resolver & ID, 14 Pin, Flying Lead -to-
5450-1810.xx 5450-1826.xx 5450-1695.xx
Straight Connectors
(DVP J3) - Feedback2, Stem Resolver & ID, 14 Pin, Flying Lead -to-
5450-1811.xx 5450-1825.xx 5450-1702.xx
Right Angle Connector
(DVP J4) - Feedback3 Redundant Motor Resolver, 7 Pin, Straight-to-
5450-1814.xx 5450-1832.xx N/A
Straight Connector
(DVP J4) - Feedback3, Redundant Motor Resolver, 7 Pin, Straight-to-
5450-1815.xx 5450-1831.xx N/A
Right Angle Connectors
(DVP J4) - Feedback3 Redundant Motor Resolver, 7 Pin, Flying Lead-
5450-1813.xx 5450-1830.xx 5450-1696.xx
to-Straight Connector
(DVP J4) - Feedback3 Redundant Motor Resolver, 7 Pin, Flying Lead-
5450-1812.xx 5450-1829.xx 5450-1699.xx
to-Right Angle Connector
Sov 7 Pin Flying Lead-to-Straight Connector 5450-1286.xx 5450-1838.xx 5450-1700.xx

Note: The suffix ".xx" denotes a cable length in feet.

30 Woodward
Manual 25182 Energy Controls Product Information

11. Magnetic Pickups

12. Active Proximity Probes

Woodward 31
Energy Controls Product Information Manual 25182

5—Software Licenses
Woodward’s Graphical Application Program (GAP™) is used to custom program Woodward’s
MicroNet™ and Atlas controllers. The GAP install software may be downloaded from the
Woodward website free or copied multiple times, but does not function unless a software license is
purchased for each computer (seat) that it is to be used on.

Each listed seat license price below includes one seat license (authorization serial number), which
can only be used on one computer.

GAP Software Programs & Kits Part Number


GAP & ABLS Programmer License 8928-810
 This seat license is used to authorize the GAP or ABLS on any one computer:
 The GAP or ABLS Install Programs must first be downloaded from Woodward's website
or from a CD kit onto the desired computer, before the received program authorization
serial number can be used to authorize its use on that computer.
 An un-activated version of the Monitor-GAP service tool program is also installed on the
target computer during a GAP or ABLS program install. This Monitor-GAP service tool
program can then be activated/authorized by purchasing a Monitor-GAP license (refer to
information listed below).
 GAP Programmer 5.XX and higher used on most products except as noted below
 GAP Programmer 3.XX programs are used to create and change application programs in
AtlasSC, 2300, and 733 controllers
 ABLS Programmer 4.XX program is used to create and change application programs in
723 and 828 controllers
 The Microsoft C/C++ 6.0 Compiler program is required to code GAP application
programs for MicroNet Pentium with NT based operating systems. Please refer to this
manual for Microsoft C/C++ 6.0 Compiler pricing.
 Software updates are free for each license, and are available by installing the latest
version of the respective software program onto the authorized computer.
 Woodward’s Monitor-GAP service tool program is also installed during GAP Programmer
install program, and can be authorized and utilized with this program

GAP & ABLS Programmer CD Kit (Use WW SW Programs Install CD Kit, 8928-1088)
 The WW Software Programs Install CD kit includes the latest GAP or ABLS Install
Programs.
 These install programs can also be downloaded for free from the Woodward website.

GAP-Read-Only Programmer License (none needed)


GAP-Demo Programmer License (none needed)
 No license is necessary for the GAP-Read-Only software program functionality. When a
GAP Programmer program is installed on a computer without an authorization serial
number, the program functions as a Read Only GAP program or as a Demo GAP
program.
 The GAP Programmer Install Program must first be downloaded from Woodward's
website or from a WW Software Programs Install CD onto the desired computer, before
it can be used as a Read-Only or Demo based GAP program.

ProTech GAP License / ToolKit Runtime License 8447-5002


 This license is used to authorize Woodward’s GAP program (function block programming)
on any one computer for use by ProTech users to create and download custom GAP
application programs into ProTechTPS, MSM, or SX models.
 Not compatible with ProTech-GII models
 Does not require GAP program to be authorized with license #8928-810
 Monitor GAP is not compatible with the ProTechTPS, MSM, or SX models

32 Woodward
Manual 25182 Energy Controls Product Information

GAP Software Programs & Kits Part Number


 When this is used as a Read Only GAP program, a user can only view the GAP program
and not make program changes.
 When this is used as a Demo GAP program, a user can create and make changes to a
program, but cannot compile code for use in a control. After 180 days, this program will
revert to a Read Only program.
 Optionally, the Monitor-GAP service tool program can be authorized and utilized with this
program functioning in its Read-Only or Demo modes of operation.

Monitor-GAP License 8928-5007


 This license is used to authorize the Monitor-GAP software service tool, and only includes
a program authorization serial number for one computer (seat).
 Monitor GAP is a licensed software service tool that allows GAP users to view real-time
values in GAP application programs when connected to a control, or running NetSim™
tools. Monitor GAP works in parallel with the GAP graphical display and superimposes the
actual run-time values into that display environment.
 The Monitor GAP program is embedded in GAP Programmer versions 3.05 and higher
and GAP Editor 2.14 and higher install programs.
 The GAP Programmer Install Program version 3.05 or higher must first be
downloaded from Woodward's website or from a CD kit, before the received program
authorization serial number can be used to authorize its use.
 Users of GAP 2.13 or lower programs must first update their GAP Editor to GAP2.14 or
higher before this license can be used.
 Monitor GAP is NOT compatible with ProTech TPS, ProTech-MSM, or ProTech-SX
devices.

Old GAP Programs (3.03 and older) CD Install Kits XXXX-XXX


 This install kit includes a CD Kit with the respective GAP X.XX install program and
associated user license.
 Old GAP programs are used to create, change, and support older application programs in
MicroNet, Atlas, and 733 controllers.
 The Microsoft C/C++ 6.0 Compiler program is required to code GAP application
programs for MicroNet Pentium or AtlasPC controllers with NT based operating
systems. Please refer to this manual for Microsoft C/C++ 6.0 Compiler pricing.
 Contact the Woodward technical assistance group for part number availability of Old GAP
programs, and associated turbine package models.

Software Service Tool Programs & Kits Part Number


Woodward Software Programs Install CD Kit 8928-1088
This install kit includes the following software install programs:
(1) GAP Programmer install program
(1) ABLS program install program
(1) Control Assistant program install program
(1) Monitor GAP tool install program
(1) NetSim Basic install program
(1) Microsoft “.NET” Framework
Note: These install programs can also be downloaded for free from the Woodward website.

Woodward 33
Energy Controls Product Information Manual 25182

Control Assistant Software License 8928-5014


 This license is used to authorize the Control Assistant Software tool on one computer
(seat).
 The Control Assistant program is used to monitor high-speed Datalog files created in
Atlas, MicroNet, and MicroNet TMR controllers.
 For CPU5200-based MicroNet Plus and Atlas-II, Control Assistant provides the following:
o Live parameter monitoring, tuning, and trending
o Off-line trending (Datalogs and archived trend data)

Control Assistant Install CD Kit (Use WW SW Programs Install CD Kit, 8928-1088)


 The WW Software Programs Install CD kit includes the latest Control Assistant
program.
 This install program can also be downloaded for free from the Woodward website.

Microsoft C/C++ 6.0 Compiler 1796-046


 This Install Kit includes a CD Kit with the Microsoft C/C++ 6.0 Compiler but no user
License. Customer must obtain a downgradable Microsoft C/C++ Compiler license to
legally use this sofware. Licenses are available from Microsoft resellers that offer group
licensing.
 The Microsoft C/C++ 6.0 Compiler is required to successfully compile Coder 3.0X for
MicroNet Pentium, NTCPU, AtlasPC, and older NetSim versions.

ToolKit Developer License 8928-5016


This license is used to authorize the Developer functionality in ToolKit, and only includes a program
authorization serial number for one computer (seat).
 TookKit is a licensed software development program used to create Service Tools and
HMIs (Human–Machine Interface) for Woodward electronic controllers 2300, 723, 733,
Atlas, and MicroNets via Woodward’s Servlink protocol over RS-232/-422/-485 serial,
CANopen, Ethernet, or telephone-line connections.
 Upon purchasing the Developer license, you will be given a serial number. It is important
for you to keep this number, as it is your proof that you own the license.

828 Application Programs CD Kit 8928-1077


 This CD Kit includes (8) eight 828 application programs based software programs and a
LON binding kit for use by distribution and or RTRs.
 The following programs are included:
828 GAP Application Prg – STD PGEN, DSLC Loadshare
828 GAP Application Prg – STD Marine, SE-Propulsion, Low Speed
828 GAP Application Prg – STD Marine, SE-Propulsion
828 GAP Application Prg – STD PGEN, DSLC Loadshare, Low Speed
828 GAP Application Prg – STD Marine, Mech Loadshare, Low Speed
828 GAP Application Prg – STD Marine, Mech Loadshare
828 GAP Application Prg – STD Industrial Process Control (424)
828 GAP Application Prg – STD Industrial Process Control (598)

34 Woodward
Manual 25182 Energy Controls Product Information

Software Service Tool Programs & Kits Part Number


NetSim Basic License 8928-5005
 This seat license is used to authorize a NetSim Basic software program, and only
includes a program authorization serial number for one computer (seat).
 The NetSim Control Executive program must first be downloaded from Woodward's
website onto the desired computer before the received program authorization serial
number can be used to authorize its use on that computer.
 NetSim Basic is a Simulation Service tool that allows GAP application programs to be run
and tested on a computer before they are downloaded into the control. With NetSim Basic,
once a GAP application program has been created it can then be executed to simulate the
open-loop control operation. Training is available to utilize GAP-to-GAP modeling
techniques to achieve closed-loop control operations with NetSim Basic.
 The supported hardware platforms are MicroNet, MicroNet TMR, Atlas, and 2301D
controllers.
 Either the Microsoft Visual C++ 2008 Express Edition Compiler or the Microsoft C/C++
6.0 Compiler program is required to operate NetSim Basic program on a computer. The
Visual C++ 2008 Express Edition is available from the Microsoft download site.
 The NetSim Basic program is only compatible with GAP programs using Coder 2.08 and
higher Coder programs.
 Contact the Woodward technical assistance group for training.

NetSim Advanced License 8928-5006


 This seat license is used to authorize a NetSim Advanced software program, and only
includes a program authorization serial number for one computer (seat).
 The NetSim Control Executive program must first be downloaded from Woodward's
website onto the desired computer before the received program authorization serial
number can be used to authorize its use on that computer.
 The NetSim Advanced program is a Simulation Service tool that allows GAP application
programs to be run and tested against turbine models on a computer before they are
downloaded into the control. With NetSim Advanced, once a GAP application program has
been created it can then be executed against a simulated turbine package to simulate the
closed-loop control operation.
 The supported hardware platforms are MicroNet, MicroNet TMR, Atlas, and 2301D
controllers.
 Either the Microsoft Visual C++ 2008 Express Edition Compiler or the Microsoft C/C++
6.0 Compiler program is required to operate NetSim Basic program on a computer. The
Visual C++ 2008 Express Edition is available from the Microsoft download site.
 The NetSim Advanced program is only compatible with GAP programs using Coder 2.08
and higher Coder programs.
 Contact the Woodward technical assistance group for training.

Software Service Tool Programs & Kits Part Number


AppManager Datalog Retrieval License - Enterprise 8928-5009
 This license is used to authorize the AppManager Program’s Datalog Retrieval
Function for 4 or more controls, and only includes a program authorization serial
number for one computer (seat).
 Datalog Retrieval Function for 1-3 controls is included in AppManager without fee.
 The AppManager Program’s Datalog Retrieval Function is embedded in AppManager
Version 2.2 and higher install programs.
 The AppManager Install Program must be downloaded from Woodward's website or
from the respective control’s service tool software directory, and onto the desired
computer, before the received program authorization serial number can be used to
authorize its use on that computer.
 The Datalog Retrieval functionality once enabled in AppManager performs automatic
archiving of Datalog files generated on one or more controls connected by a network. The
collected files are given unique names based upon the original file name, the last time of
modification, and the source control.

Woodward 35
Energy Controls Product Information Manual 25182

Auxiliary Devices
USB to Serial Adapter Kit 8928-463
(Includes USB to 9 Pin Sub-D converter, 6 foot Serial Cable, & Software driver Installation CD)
Allows USB ports to communicate to Woodward products (SPCs, 2301Ds, AtlasSCs, etc.) via serial
communications.

MicroNet TMR Programmer (PCMCIA Flash Card) 1790-9026


4 MB Flash Memory Card 1790-789
10 MB Flash Memory Card 1790-792

36 Woodward
Manual 25182 Energy Controls Product Information

6—Power Generation Products


Part
Number
1. easYgen™ Stand-alone Genset Controls
A. easYgen-300 Series Single Genset Control (product spec 37217)

easYgen-320/X 8440-1800
Genset control for auto start, one breaker (GCB) operation, 1 phase-2 wire generator voltage
measurement, generator voltage/frequency protection, 5 discrete inputs (up to 2 DI’s configurable)
and 4 relay outputs (1 configurable), engine over/underspeed protection, J1939 visualization via
CAN bus and MPU input, rated to 480 Vac. PC configuration through Woodward LeoPC software
(DPC or USB-UART connector required).

easYgen-350/X 8440-1801
Genset control for auto start, AMF, two breaker (GCB & MCB) transfer operation, 1 phase-2 wire
generator voltage measurement, 3 phase-4 wire mains voltage measurement, generator
voltage/frequency protection, 5 discrete inputs (up to 2 DI’s configurable), 6 relay outputs (2
configurable), engine over/underspeed protection, J1939 visualization via CAN bus and MPU input,
rated to 480 Vac. PC configuration through Woodward LeoPC software (DPC or USB-UART
connector required).

B. easYgen-1000 Series Single Genset Control with CAN/J1939 (product spec


37180)

easYgen-1500 8440-1809
Single genset control for remote and auto start, breaker control with AMF, open transition load
transfer, FlexApp, Flex-In, FlexRange, FlexCAN, DynamicsLCD, LogicsManager, generator
protection, J1939 protocol for ECU coupling and alarm management, separate voltage inputs rated
to 120 and 480 Vac, 5-amp CT inputs. PC configuration through Woodward LeoPC software (DPC
or USB-UART connector required).

C. easYgen Stand-alone Genset Control Accessories

easYlite-100 Remote Annunciation Panel (product spec 37279) 8446-1023


CAN bus based remote annunciation with 18 LED output displays for connection to the
easYgen-1000, easYgen-2000 and easYgen-3000 series. NFPA 99 and 110 compliant.

IKD 1 Discrete Input/Output Expansion Module (product spec 37171) 8440-2028


Discrete expansion card (8x isolated DI, 8x isolated DO, isolated power supply), CAN
communication, UL/cUL Listed

DPC, Communication Cable 5417-557


Configuration cable for easYgen-300 and easYgen-1000 series controls. Serial 232 (9-pin) to RJ45

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for easYgen-300 and easYgen-1000 series controls. USB to RJ45

ESENET Ethernet Gateway (Application Note 37576) 8445-1044


CANopen-Ethernet gateway to interface our CANOpen genset and ATS controllers with
Modbus/TCP networks.

ESEPRO Profibus Gateway (Application Note 37577) 8445-1046


Profibus gateway to interface our genset and ATS controllers with Profibus-DP networks.

EPU-100 Remanence Voltage Converter (product spec 37562) 8445-1045


This Electronic Pickup Unit receives the electrical signal and converts it into an “MPU signal” which
can be fed into an easYgen genset control to interpret the speed of rotation of the generator. It is
particular suitable to work with the very small voltage an asynchronous generator produces until its
breaker is closed.

Woodward 37
Energy Controls Product Information Manual 25182

Part
Number

NETBITER Remote Communications Gateway (Application Note : HMSI-27-214)


The Netbiter EasyConnect 250 Gateway connects with easYgen controls through RS-485 Modbus
interface and enables to provide remote communication through cloud connection. It is sold and
supported through HMS sales network.

CAN Fiber Optic Communmication Gateway (Application Note 37598) 8445-1049


CAN Open Fiber Optic Gateway to interface our CANOPEN genset and ATS for enabling long
distance communication.

2. easYgen™ Paralleling Genset Controls


A. easYgen-2000 Series Paralleling Genset Control (product spec 37448)
Paralleling genset controls for 1 unit to utility, or up to 16 units in island operation. Remote and auto
start, load sharing with load-dependent start/stop, synchronization breaker control with AMF,
open/closed transition load transfer, soft loading, interchange. Generator, engine, and mains
protection. Integrated LogicsManager Boolean programming provides flexibility for a wide range of
applications and operating modes. Induction generator compatible. Separate voltage inputs rated to
120 and 480 Vac. PC configuration through Woodward ToolKit software (DPC or USB-UART
connector required). 1-amp or 5-amp CT input versions available.

easYgen-2200 Package 1 (MPU input) 8440-1855


Speed measurement via magnetic pickup, 1 analog output. 5-amp CT inputs.

easYgen-2200 Package 2 (ECU input) 8440-1857


Features of easYgen-2200/P1 but with CAN/J1939 for speed control (no MPU). 5-amp CT inputs.

easYgen-2300 Package 1 8440-2080


Speed measurement via frequency measurement, 2 analog outputs, 5-amp CT inputs; UL/cUL
pending.

easYgen-2300 Package 2 (ECU input) 8440-2058


Features of easYgen-2300/P1 but with CAN/J1939 for speed control (no MPU), 2 analog outputs,
5-amp CT inputs; UL/cUL pending.

easYgen-2500 Package 1 (MPU or ECU input, RS-485 Modbus) 8440-1884


Speed measurement via magnetic pickup. CAN/J1939 for speed control. RS-485 Modbus RTU, 4
analog outputs. 5-amp CT inputs.

B. easYgen-2000 Series Rental Genset Control (product spec 37543)

easYgen-2500 Rental Package (MPU or ECU input, RS-485 Modbus) 8440-2029


Complete feature set of the easYgen-2500 Package 1 plus added functionality for rental genset
applications, including (4) switchable parameter sets to change rated values for system frequency,
engine speed, generator voltage, mains/busbar voltage, generator real and reactive power and
generator current, as well as control setpoints for voltage, frequency, load and power factor.
2-breaker control (GCB, MCB). 5 amp CT inputs.

C. easYgen-2000 Series Asynchronous Genset Control (product spec 37568)

Asynchron Kit 2000 8923-2074


Complete feature set of the easYgen-2500 Package 1 plus a remanence voltage converter (EPU-
100). Manual#37561 describes the application note for asynchronous use.

38 Woodward
Manual 25182 Energy Controls Product Information

Part
Number

D. easYgen-3000 Series Paralleling Genset Control (product spec 37258)

Paralleling genset controls for up to 32 units in isolated or utility parallel operation. Remote and
auto start, load sharing with load-dependent start/stop, synchronization breaker control with AMF,
open/closed transition load transfer, soft loading, interchange. Generator, engine, and mains
protection. Display and evaluation of (100) common J1939 analog values. Integrated
LogicsManager Boolean programming provides flexibility for a wide range of applications and
operating modes. Induction generator compatible. Separate voltage inputs rated to 120 and 480
Vac. PC configuration through Woodward ToolKit software. 1-amp or 5-amp CT input versions
available. Door mount (with 5.7” color display) or back panel mount (aluminum housing, no display)
versions available.

easYgen-3200 Package 1 8440-2050


Door mount, standard I/O set. 5 amp CT inputs.

easYgen-3200 Package 2 (cogeneration version) 8440-2052

Complete feature set of the easYgen-3200 Package 1 plus added functionality for gaseous-fuel
engines and cogeneration (heat and power) applications, including 3 freely-configurable internal
PID controllers and I/O expansion capability over CAN communication (discrete and/or analog I/O
may be added through external modules and used for monitoring and control). 5-amp CT inputs.

easYgen-3100 Package 1 8440-2054


Back panel mount, standard I/O set. 5 amp CT inputs.

easYgen-3100 Package 2 (cogeneration version) 8440-2056


Complete feature set of the easYgen-3100 Package 1 plus added functionality for gaseous-fuel
engines and cogeneration (heat and power) applications, including 3 freely-configurable internal
PID controllers and I/O expansion capability over CAN communication (discrete and/or analog I/O
may be added through external modules and used for monitoring and control). 5-amp CT inputs.

E. easYgen-3000 Series for Complex Breaker Applications (product specification


37523)

easYgen-3500 Package 1 8440-1934


Complete feature set of the easYgen-3200 Package 1 plus added functionality for complex
distribution system applications with multiple utility feeds and/or tie breakers, including 3-breaker
control (GCB, GGB (generator group breaker), MCB) and connectivity with up to (16) LS-5 circuit
breaker controllers. Door mount, standard I/O set. 5 amp CT inputs.

easYgen-3500 Package 2 8440-1936


Complete feature set of the easYgen-3500 Package 1 plus additional 10 digital outputs, 11 digital
monitoring inputs, 2 sinking output (kVArh & kWh pulses), 3 analogous 0/4-20mA outputs,
7 analogous inputs, Door mount, standard I/O set. 5 amp CT inputs.

easYgen-3400 Package 1 8440-1945


Complete feature set of the easYgen-3100 Package 1 plus added functionality for complex
distribution system applications with multiple utility feeds and/or tie breakers, including 3-breaker
control (GCB, GGB (generator group breaker), MCB) and connectivity with up to (16) LS-5 circuit
breaker controllers. Back panel mount, standard I/O set. 5 amp CT inputs.

easYgen-3400 Package 2 8440-2078


Complete feature set of the easYgen-3400 Package 1 plus additional 10 digital outputs, 11 digital
monitoring inputs, 2 sinking output (kVArh & kWh pulses), 3 analog 0/4-20mA outputs, 7 analog
inputs.

Woodward 39
Energy Controls Product Information Manual 25182

Part
Number

F. easYgen-3000 Series for Complex Breaker Applications - Marine Version


(product spec 37533)

easYgen-3500 Marine Package 8440-2047


Complete feature set of the easYgen-3500 Package 1 plus added functionality for marine
applications, including redundant GCB monitoring and visualization of countdown timers on display.
DNV, Lloyd’s Register, ABS, GL, and BV type approvals. Door mount, standard I/O set. 5 amp CT
inputs.

easYgen-3400 Marine Package 8440-2045


Complete feature set of the easYgen-3400 Package 1 plus added functionality for marine
applications, including dual-redundant GCB monitoring. DNV, Lloyd’s Register, ABS, GL, and BV
type approvals. Back panel mount, standard I/O set. 5 amp CT inputs.

G. easYgen-3000 Series Rental Genset Control (product spec 37544)

easYgen-3500 Rental Package 8440-2030


Base feature set of the easYgen-3500 Package 1 plus added functionality for rental genset
applications, including (4) switchable parameter sets to change rated values for system frequency,
engine speed, generator voltage, mains voltage, busbar voltage, generator real and reactive power
and generator current, as well as control setpoints for voltage, frequency, load and power factor.
3-breaker control (GCB, GGB (generator group breaker), MCB). 5-amp CT inputs. Note- not
compatible with the LS-5 circuit breaker control.

easYgen-3400 Rental Package 8440-2163


Base feature set of the easYgen-3400 Package 1 plus added functionality for rental genset
applications, including (4) switchable parameter sets to change rated values for system frequency,
engine speed, generator voltage, mains voltage, busbar voltage, generator real and reactive power
and generator current, as well as control setpoints for voltage, frequency, load and power factor.
3-breaker control (GCB, GGB (generator group breaker), MCB). 5-amp CT inputs. Note- not
compatible with the LS-5 circuit breaker control.

H. easYgen-3000 Series Asynchronous Genset Control (product spec 37568)

Asynchron Kit 3000 8923-2073


Complete feature set of the easYgen-3500 Package 2 plus a remanence voltage converter (EPU-
100). Manual#37561 describes the application note for asynchronous use.

I. easYgen Paralleling Genset Control Accessories

RP-3000 Remote Control Panel (product spec 37446) 8446-1048


Remote control and annunciation panel for use with either the back-panel mounted easYgen-3100
or door-mounted easYgen-3200 generator controls (limit of one remote panel per easYgen
controller). Allows remote control, remote visualization (including synch-scope) and password-
protected remote configuration. Allows manual operation of easYgen-3100 controls. CAN
communication. Color LCD.

RP-3000 Remote Control Panel – Marine Version (product spec 37446) 8446-1046
Complete feature set of the RP-3000 for marine applications, for use with the easYgen-3400/3500
marine package genset controllers. DNV, Lloyd’s Register, ABS, GL, and BV type approvals.

RP-3000 Remote Control Panel – Rental Version (product spec 37446) 8446-1059
Complete feature set of the RP-3000 for marine applications, for use with the easYgen-3400 rental
package genset controllers. Note: Not compatible with the easYgen-3500 rental package.

40 Woodward
Manual 25182 Energy Controls Product Information

Part
Number

easYlite-100 Remote Annunciation Panel (product spec 37279) 8446-1023


CAN bus based remote annunciation with 18 LED output displays for connection to the
easYgen-2000 and easYgen-3000 series. NFPA 99 and 110 compliant.

LS-5 Circuit Breaker Control (product spec 37522)


Utility/bus tie breaker control with synchronization for easYgen-3400/3500, soft load/unload,
protection and decoupling features. CAN communication for connection of up to (32) easYgen-
3500 or easYgen-3400 models, plus up to (16) LS-5 controls for complex system control. Up to (32)
bus segments can be defined. True RMS 3-Phase voltage and current measurement, user-defined
monitoring limits and Modbus RS-485 communication allow the LS-5 to be used independently for
relaying in PLC-based systems. Separate voltage inputs rated to 120 and 480 Vac. PC
configuration through Woodward ToolKit software (DPC or USB-UART connector required). 1-amp
or 5-amp CT input versions available. Door mount (with display) or back panel mount (aluminum
housing, no display) versions available.

LS-521 8440-1947
Door mounted version with display. Auto and manual operation. 5 amp CT inputs.

LS-511 8440-1946
Back-panel mounted version with aluminum housing (no display). Includes (8) programmable
LED’s for annunciation with customizable paper strip, ready-for-operation LED and lamp test
button. 5 amp CT inputs.

LS-5 Circuit Breaker Control - Marine Version (product spec 37545)


Complete feature set of the LS-5, with DNV Certification for marine applications.

LS-521 Marine Package 8440-2075


Door mounted version with display. Auto and manual operation. 5 amp CT inputs. DNV, Lloyd’s
Register, ABS, GL, and BV type approvals.

LS-511 Marine Package 8440-2077


Back-panel mounted version with aluminum housing (no display). Includes (8) programmable
LED’s for annunciation with customizable paper strip, ready-for-operation LED and lamp test
button. 5 amp CT inputs. DNV, Lloyd’s Register, ABS, GL, and BV type approvals.

PowerGen Learning Module (Product Spec 03421) 8447-1012


The Power Generation Learning Module provides the student with an interactive learning
environment that covers Power Generation and Power Generation control Modes. Fundamentals of
speed controls and the dynamic tuning of a PID (proportional, Integral, Derivative) type speed
control algorithm are also included. Note: this is a learning tool and not a simulation/virtual;
prototyping tool.

LSG Load Share Gateway Analog/RS-485 (product spec 37451)


LSG (real [kw] load sharing) 8444-1075
Provides real and reactive power load sharing from easYgen paralleling genset controls with GCP-
30 and EGCP-2 generator controls over RS-485, or real power only load sharing with legacy
controls through a configurable analog bias signal.

LSG (reactive [kVAR] load sharing) 8444-1074


Provides reactive power load sharing from easYgen paralleling genset controls with legacy controls
through a configurable analog bias signal.

DPC Communication Cable 5417-557


Configuration cable for easYgen-2000 series controls and LS-5 circuit breaker controls. Serial 232
(9-pin) to RJ45.

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for easYgen-2000 series controls and LS-5 circuit breaker controls. USB to
RJ45.
Part

Woodward 41
Energy Controls Product Information Manual 25182

Number

IKD 1 Discrete Input/Output Expansion Module (product spec 37171) 8440-2028


Discrete expansion card (8x isolated DI, 8x isolated DO, isolated power supply), CAN
communication.

ESENET Ethernet Gateway (Application Note 37576) 8445-1044


CANopen-Ethernet gateway to interface our CANOpen genset and ATS controllers with
Modbus/TCP networks.

ESEPRO Profibus Gateway (Application Note 37577) 8445-1046


Profibus gateway to interface our genset and ATS controllers with Profibus-DP networks.

EPU-100 Remanence Voltage Converter (product spec 37562) 8445-1045


This Electronic Pickup Unit receives the electrical signal and converts it into an “MPU signal” which
can be fed into an easYgen genset control to interpret the speed of rotation of the generator. It is
particular suitable to work with the very small voltage an asynchronous generator produces until its
breaker is closed.

ActiVgen Engine Speed Control (product spec 03419) 8440-2100


Used as a separate, external primary speed control with user-configurable PID settings. Gives the
user full access to tune the Caterpillar engine directly.

CAN Fiber Optic Communmication Gateway (Application Note 37598) 8445-1049


CAN Open Fiber Optic Gateway to interface our CANOPEN genset and ATS for enabling long
distance communication.

NETBITER Remote Communications Gateway (Application Note : HMSI-27-214)


The Netbiter EasyConnect 250 Gateway connects with easYgen controls through RS-485 Modbus
interface and enables to provide remote communication through cloud connection. It is sold and
supported through HMS sales network.

Thermocouple Scanner (Axiomatic Product Spec: TDAXTC20)


The thermocouple scanner monitors up to 20 thermocouples and provides the temperature
information to the engine control system over SAE J1939 CAN bus. It is sold and supported
through Axiomatic Technology Corporation sales network.

3. EGCP-2 Generator Controls


A. EGCP-2 Series (product spec 03219)
EGCP-2 High Voltage (150-300 Vac) 8406-120
Paralleling genset control for up to 8 units, remote start, synchronization, generator/engine
protection, load/var sharing, automatic sequencing, Modbus communication interfaces. High-
voltage version (150–300 Vac PT sensing range).

EGCP-2 Low Voltage (50-150 Vac) 8406-121


Paralleling genset control for up to 8 units, remote start, synchronization, generator/engine
protection, load/var sharing, automatic sequencing, Modbus communication interfaces. Low-
voltage version (50–150 Vac PT sensing range).

B. EGCP-2 Generator Control Accessories

Conversion Cable 5417-551


Cable allows PC configuration of EGCP-2 series controls, converts RS-422 to RS-232.

Connector Kit 8928-301


Wiring harness connector kit, required for connection to each EGCP-2 controller.

LSG Load Share Gateway Analog/RS-485 (product spec 37451)


LSG (real [kw] load sharing) 8444-1075
Provides real and reactive power load sharing from easYgen paralleling genset controls with
EGCP-2 generator controls over RS-485.

42 Woodward
Manual 25182 Energy Controls Product Information

Part
Number

4. Switchgear Controls
A. DTSC-200 Series Automatic Transfer Switch Control (product spec 37398)
DTSC-200, 120 & 480 Vac 8440-1868
For open, delayed or closed transfer using circuit breakers or latching contactors. In-phase
monitoring (synch check) can be enabled for all transfer modes. Selectable applications: Main-
Gen, Gen-Gen or Main-Main. LogicsManager programmable Boolean logic functions allow for
complex transfer schemes without using external relay logic or a separate PLC. Transfer inhibit,
extended parallel, source selection, load shed/restore, elevator pre-signal features are all standard.
Expandable discrete I/O, PC and front face programmability (password protected), CANopen and
RS-485 Modbus communication. Separate 120 and 480 Vac voltage inputs. 1-amp or 5-amp CT
input versions available.

B. DTSC-50 Series Automatic Transfer Switch Control (product spec 37455)


DTSC-50, 50-480 Vac 8440-1894
For open transfer using contactors. Three-phase voltage and frequency measurement for mains
and generator, auto or manual operation. Seven-segment display gives voltage, frequency, alarm
codes, engine hours and number of transfers. Freely configurable inputs/outputs. Breaker
open/close monitoring eliminates the need for external interlock relays. Engine start/cool-down,
maintenance counter. 50-480 Vac rated voltage. PC and front face programmability.

C. LS-5 Circuit Breaker Control (product spec 37522)


Utility/bus tie breaker control with synchronization, soft load/unload, protection and decoupling
features. CAN communication for connection of up to (32) easYgen-3500 or easYgen-3400
models, plus up to (16) LS-5 controls for complex system control. Up to (32) bus segments can be
defined. True RMS 3-Phase voltage and current measurement, user-defined monitoring limits and
Modbus RS-485 communication allow the LS-5 to be used independently for relaying in PLC-based
systems. Separate voltage inputs rated to 120 and 480 Vac. PC configuration through Woodward
ToolKit software (DPC or USB-UART connector required). 1-amp or 5-amp CT input versions
available. Door mount (with display) or back panel mount (aluminum housing, no display) versions
available.

LS-521 8440-1947
Door mounted version with display. Auto and manual operation. 5 amp CT inputs.

LS-511 8440-1946
Back-panel mounted version with aluminum housing (no display). Includes (8) programmable
LED’s for annunciation with customizable paper strip, ready-for-operation LED and lamp test
button. 5 amp CT inputs.

D. LS-5 Circuit Breaker Control - Marine Version (product spec 37545)


Complete feature set of the LS-5, with DNV, Lloyd’s Register, ABS, GL, and BV type approvals for
marine applications.

LS-521 Marine Package 8440-2075


Door mounted version with display. Auto and manual operation. 5 amp CT inputs. DNV, Lloyd’s
Register, ABS, GL, and BV type approvals.

LS-511 Marine Package 8440-2077


Back-panel mounted version with aluminum housing (no display). Includes (8) programmable
LED’s for annunciation with customizable paper strip, ready-for-operation LED and lamp test
button. 5 amp CT inputs. DNV, Lloyd’s Register, ABS, GL, and BV type approvals.

Woodward 43
Energy Controls Product Information Manual 25182

Part
Number

E. Switchgear Controls Accessories

LS-511 DIN-Rail Mounting Accessory Bracket 8923-1746


Bracket and screw kit for mounting the LS-511 to standard DIN rails.

IKD 1 Discrete Input/Output Expansion Module (product spec 37171 8440-2028


Discrete expansion card (8x isolated DI, 8x isolated DO, isolated power supply), CAN
communication

DPC Communication Cable 5417-557


Configuration cable for DTSC transfer switch controls and LS-5 circuit breaker controls. Serial 232
(9-pin) to RJ45.

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for DTSC transfer switch controls and LS-5 circuit breaker controls. USB to
RJ45.

ESENET Ethernet Gateway (Application Note 37576) 8445-1044


CANopen-Ethernet gateway to interface our CANOpen genset and ATS controllers with
Modbus/TCP networks.

ESEPRO Profibus Gateway (Application Note 37577) 8445-1046


Profibus gateway to interface our genset and ATS controllers with Profibus-DP networks.

NETBITER Remote Communications Gateway (Application Note : HMSI-27-214)


The Netbiter EasyConnect 250 Gateway connects with easYgen controls through RS-485 Modbus
interface and enables to provide remote communication through cloud connection. It is sold and
supported through HMS sales network.

CAN Fiber Optic Communmication Gateway (Application Note 37598) 8445-1049


CAN Open Fiber Optic Gateway to interface our CANOPEN genset and ATS for enabling long
distance communication.

5. Synchronizers
A. SPM-A Analog Synchronizer (product spec 82383)

SPM-A, Analog Speed & Phase Synchronizer, no voltage matching 9907-028


SPM-A, Analog Speed & Phase Synchronizer, 1% voltage matching 9907-029
SPM-A, Analog Speed & Phase Synchronizer, 5% voltage matching 9905-003

B. SPM-D10 Digital Synchronizer for 1 Breaker, 1-Phase Synch (product spec


37297)

SPM-D10, 100 Vac 5448-890


SPM-D10, 400 Vac 8440-1019
Synchronizer for 1 breaker, discrete raise/lower for speed & voltage bias

SPM-D10/N, 100 Vac 8440-1432


SPM-D10/N, 400 Vac 8440-1433
Synchronizer for 1 breaker, discrete raise/lower for speed & voltage bias, wide-range power supply
(90-265 Vac/dc)

SPM-D10/X, 100 Vac 5448-893


SPM-D10/X, 400 Vac 8440-1301
Synchronizer for 1 breaker, analog outputs for speed & voltage bias

44 Woodward
Manual 25182 Energy Controls Product Information

Part
Number

SPM-D10/XN, 100 Vac 8440-1667


SPM-D10/XN, 400 Vac 8440-1668
Synchronizer for 1 breaker, analog outputs for speed & voltage bias, wide-range power supply
(90-265 Vac/dc)

C. SPM-D10 Digital Synchronizer for 1 Breaker, 3-Phase Synch (product spec


37298)

SPM-D10/YB, 100 Vac 5448-906


SPM-D10/YB, 400 Vac 8440-1021
Synchronizer for 1 breaker (3-phase voltage measurement), discrete raise/lower for speed &
voltage bias

SPM-D10/NYB, 100 Vac 8440-1434


SPM-D10/NYB, 400 Vac 8440-1435
Features of SPM-D10/YB + wide-range power supply (90-250 Vac/dc)

D. SPM-D11 Digital Synchronizer for 1 Breaker, 3-Phase Synch, Load Control


(product spec 37292)

SPM-D11/LSXR, 12/24 V, 100 Vac 8440-1706


SPM-D11/LSXR, 12/24 V, 400 Vac 8440-1666
Synchronizer for 1 breaker with power control and analog power/var sharing, 3 alarm and 3
signaling relays, analog outputs for speed & voltage bias

E. Synchronizer Accessories

DPC Communication Cable 5417-557


Configuration cable for SPM-D Synchronizers. Serial 232 (9-pin) to RJ45

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for SPM-D Synchronizers. USB to RJ45

6. Load Share Controls


A. Analog Load Sharing Modules (product specification 82686)

LSM, ±3 Vdc bias output 9907-173


Load sharing module with isochronous and droop load-sharing capability, 115/230 Vac power input,
±3 Vdc bias output

LSM, CAT PWM bias output (replaces 9907-175) 9907-838


Load sharing module with isochronous and droop load-sharing capability, 24 Vdc power input,
Caterpillar PWM bias output

LSM, 0.5 to 4.5 Vdc bias output 9907-252


Load sharing module with isochronous and droop load-sharing capability, 24 Vdc power input,
0.5-4.5 Vdc bias output

Woodward 45
Energy Controls Product Information Manual 25182

Part
Number

B. DSLC-2 Digital Load Share Control (product specification 37493)

DSLC-2 8440-1878
Paralleling genset control for up to 32 units in isolated or mains parallel operation combining
synchronizer, load sensor, load control, dead bus closing system, VAR, power factor and process
control. Dedicated Ethernet port for communications between DSLC-2 and MSLC-2 units. Second
Ethernet port for remote control and monitoring using Modbus TCP, allowing DCS and PLC
interfacing. Redundant Ethernet communication enabled. Modbus RTU is available through a
separate RS-485 port. PC programming using Woodward Toolkit software. Separate voltage inputs
rated to 120 and 480 Vac. 1-amp or 5-amp CT input versions available.

C. MSLC-2 Master Load Share Control (product specification 37494)

MSLC-2 8440-1877
Synchronizer, load sensor, import/export and power factor control, master process controller.
Dedicated Ethernet port for communications between up to 32 DSLC-2 and 16 MSLC-2 units on up
to 8 bus segments. Second Ethernet port for remote control and monitoring using Modbus TCP,
allowing DCS and PLC interfacing. Redundant Ethernet communication enabled. Modbus RTU is
available through a separate RS-485 port. PC programming using Woodward Toolkit software.
Separate voltage inputs rated to 120 and 480 Vac. 1-amp or 5-amp CT input versions available.

D. DSLC-2 & MSLC-2 Accessories

Ethernet Switch 1752-423


Unmanaged rail switch with 8 Fast-Ethernet ports (10/100base- TX). Redundant 24 volt power
input, DIN-rail mounted, 0-60 °C operation. Class 1 Div 2 cUL rated.

Fiber Optic Switch 1711-1069


Unmanaged Industrial Ethernet Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s)
and Fast-Ethernet (100 Mbit/s). 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-
negotiation, auto-polarity, 1 x 100BASE-FX, MM cable, SC sockets.

7. Digital Multi-Function Relays


A. MFR 300 Multifunction Relay / Measuring Transducer with CANopen / RS-485
Modbus Communication

MFR300-11M, 100 Vac / 1 A 8444-1089


MFR300-15M, 100 Vac / 5 A 8444-1090
MFR300-71M, 690 Vac / 1 A 8444-1091
MFR300-75M, 690 Vac / 5 A 8444-1092
MFR300-75M/SU03, 690 Vac / 5 A 8444-1093
MFR300-75M/K28, 690 Vac / 5 A 8444-1094

B. LS-5 Circuit Breaker Control (product spec 37522)


True RMS 3-Phase voltage/current measurement, Modbus RS-485 communication. Over/under
voltage (27/59), over/under frequency (81 O/U), voltage balance/rotation (47), phase shift (78),
ROCOF (81), synch check (25). 3 configurable relay outputs. 8-40 Vdc power. Separate 120 and
480 Vac voltage inputs. PC configuration through Woodward ToolKit software (DPC or USB-UART
connector required). 1-amp or 5-amp CT input versions available.

LS-511 8440-1946
Back-panel mount with aluminum housing (no display). 8 programmable LED’s for annunciation
with customizable paper strip, ready-for-operation LED and lamp test button. 5-amp CT inputs.

46 Woodward
Manual 25182 Energy Controls Product Information

Part
Number

LS-511 DIN-Rail Mounting Accessory Bracket 8923-1746


Bracket and screw kit for mounting the LS-511 to standard DIN rails.

easYprotec Multifunction Relay


Measuring transducer with CANopen / Modbus Communication
easYprotec-1410-1 8441-1160
easYprotec-1410-7 8441-1161
easYprotec-1510-1 8441-1162
easYprotec-1510-7 8441-1163

C. Multi-Function Relay Accessories

DPC Communication Cable 5417-557


Configuration cable for MFR & ESDR series controls. Serial 232 (9-pin) to Serial RJ45

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for MFR & ESDR series controls. USB to RJ45.

8. Expansion Modules
A. IKD 1 Discrete Input/Output Expansion Module (product specification 37171)

IKD 1 8440-2028
Discrete expansion card (8x isolated DI, 8x isolated DO, isolated power supply), CAN
communication

B. Expansion Module Accessories

DPC Communication Cable 5417-557


Configuration cable for TUG, UMT, & IKD series controls. Serial 232 (9-pin) to Serial RJ45

USB-UART Converter (product spec 51381) 5417-1251


Configuration cable for TUG, UMT, & IKD series controls. USB to RJ45

9. Accessories and Spare Parts


A. Brackets

Brackets 8923-1023
Fits SPMD, MFR-13, GW4. Set of two (2 brackets, 2 level adjuster, 4 self-drilling screws, 4 back-
plate screws)

B. Fixing Clamps

Fixing Clamps LR01543


For all APRANORM housing types (one piece). Set of 2.

C. Terminal Strip Kits


Kit-Plug Set for UMT 1 8923-1027
Kit-Plug Set for GCP-30 8923-1028
Kit-Plug Set for SPM-D 8923-1032
Kit-Plug Set for easYgen-3100, 3200 and 3500 series 8923-1314
Kit-Plug Set for easYgen-3400 series 8928-7371
Kit-Plug Set for LS-511 (back-pan mount) 8928-7336
Kit-Plug Set for easYgen-2200 series and LS-521 (door mount) 8928-7286
Kit-Plug Set for easYgen-2500 series 8928-7297
Kit-Plug Set for easYgen-1000 series 8923-1055

Woodward 47
Energy Controls Product Information Manual 25182

Kit-Plug Set for easYgen-320/X 8923-1157


Kit-Plug Set for easYgen-350/X and DTSC-50 8923-1158
Kit-Plug Set for DTSC-200 8923-1805
Kit-Plug Set for DSLC-2 and MSLC-2 8923-1806

48 Woodward
Manual 25182 Energy Controls Product Information

7—Power Distribution Products

1. HighPROTEC Ordering Codes


A. HighPROTEC Ordering Code—MCA4 (product spec DOK-FLY_MCA4-2E)

Directional Feeder Protection and Grid Coupling — Current, Voltage, Frequency, Power,
Control up to six breakers

MCA4 -2
Version 2 with USB, enhanced communication options and new front plate
Digital Binary Housing Large
Inputs output relays display
8 7 B2 Yes A
16 13 B2 Yes D
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector K*
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).

The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

Woodward 49
Energy Controls Product Information Manual 25182

B. HighPROTEC Ordering Code—MRA4 (product spec DOK-FLY_MRA4-2E)

Directional Feeder Protection and Grid Coupling — Current, Voltage, Frequency, Power,
Control of one breaker

MRA4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary Housing Large
Inputs output relays display
8 7 B2 No A
16 13 B2 No D
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices

50 Woodward
Manual 25182 Energy Controls Product Information

C. HighPROTEC Ordering Code—MRI4 (product spec DOK-FLY_MRI4-2E)

Non-directional Feeder Protection — Current, Control of one breaker

MRI4 -2 A
Version 2 with USB, enhanced communication options and user options
Digital Binary Housing Large
Inputs output relays display
8 6 B1 No
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector K*
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French
* Within every communication option only one communication protocol is usable.
Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

Woodward 51
Energy Controls Product Information Manual 25182

D. HighPROTEC Ordering Code—MRU4 (product spec DOK-FLY_MRU4-2E)

Voltage and Frequency Protection and Grid Coupling — Control of one breaker

MRU4 -2 A 0
Version 2 with USB, enhanced communication options and user options
Digital Binary Housing Large
Inputs output relays display
8 6 B1 No
Hardware variant
Standard
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices

52 Woodward
Manual 25182 Energy Controls Product Information

E. HighPROTEC Ordering Code—MRDT4 (product spec DOK-FLY_MRDT4-2E)

Non-directional Transformer Differential Protection — Current Only, Control of one breaker

MRDT4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary Housing Large
Inputs output relays display
8 7 B2 No A
16 13 B2 No D
Hardware variants
Phase Current 5 A/1 A, W1/W2 Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, W1 Sen. Gr. Curr. 5 A/1 A, W2 Gr. Curr. 5 A/1 A 1
Phase Current 5 A/1 A, W1 Gr. Curr. 5 A/1 A, W2 Sen. Gr. Curr. 5 A/1 A 2
Phase Current 5 A/1 A, W1/W2 Sen. Gr. Curr. 5 A/1 A 3
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).

The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

Woodward 53
Energy Controls Product Information Manual 25182

F. HighPROTEC Ordering Code—MCDTV4 (product spec DOK-FLY_MCDTV4-2E)

Directional Transformer Differential Protection and Grid Coupling — Current, Voltage,


Frequency, Power, Control up to six breakers
MCDTV4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary Housing Large
Inputs output relays display
8 7 B2 Yes A
16 13 B2 Yes B
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, W1 Sen. Gr. Curr. 5 A/1 A, W2 Gr. Curr. 5 A/1 A 1
Phase Current 5 A/1 A, W1 Gr. Curr. 5 A/1 A, W2 Sen. Gr. Curr. 5 A/1 A 2
Phase Current 5 A/1 A, W1/W2 Sen. Gr. Curr. 5 A/1 A 3
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector K*
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

54 Woodward
Manual 25182 Energy Controls Product Information

G. HighPROTEC Ordering Code—MRM4 (product spec DOK-FLY_MRM4-2E)

Motor Protection — Current, Control of one breaker


MRM4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary Analog Housing Large
Inputs output relays Inputs/Outputs display
8 6 0/0 B1 No A
4 4 0/1 B1 No B
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol A*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

Woodward 55
Energy Controls Product Information Manual 25182

H. HighPROTEC Ordering Code—MRMV4 (product spec DOK-FLY_MRMV4-2E)

Motor Protection — Current, Voltage, Frequency, Power, Control of one breaker

MRMV4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary Analog Housing Large
Inputs output relays Inputs/Outputs display
8 7 0/4 B2 No A
8 13 0/4 B2 No C
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol * A
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

56 Woodward
Manual 25182 Energy Controls Product Information

I. HighPROTEC Ordering Code—MCDGV4 (product spec DOK-FLY_MCDGV4-2E)

Generator Differential Protection and Grid Coupling — Current, Voltage, Frequency, Power,
Control up to six breakers
MCDGV4 -2
Version 2 with USB, enhanced communication options and user options
Digital Binary output Analog Housing Large
Inputs relays Inputs/Outputs display
16 11 0/0 B2 Yes A
8 11 2/2 B2 Yes B
24 11 0/0 B2 Yes C
16 16 0/0 B2 Yes D
Hardware variant 2
Phase Current 5 A/1 A, Ground Current 5 A/1 A 0
Phase Current 5 A/1 A, Sensitive Ground Current 5 A/1 A 1
Housing and mounting
Door mounting A
Door mounting 19” (flush mounting) B
Communication protocol
Without protocol * A
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45 C*
Profibus-DP | optic fiber/ST-connector D*
Profibus-DP | RS485/D-SUB E*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | optic fiber/ST-connector F*
Modbus RTU, IEC60870-5-103, DNP3.0 RTU | RS485/D-SUB G*
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100MB/RJ45 H*
IEC60870-5-103, Modbus RTU, DNP3.0 RTU | RS485/terminals I*
Modbus TCP, DNP3.0 TCP/UDP | Ethernet 100 MB/RJ45
IEC61850, Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex K*
connector
Modbus TCP, DNP3.0 TCP/UDP | Optical Ethernet 100MB/LC duplex connector L*
Harsh Environment Option
None A
Conformal Coating B
Available menu languages
Standard English/German/Spanish/Russian/Polish/Portuguese/French

* Within every communication option only one communication protocol is usable.


Smart view can be used in parallel via the Ethernet interface (RJ45).
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.

Woodward 57
Energy Controls Product Information Manual 25182

2. HighPROTEC Services
HPTCON 01
Creation of the device configuration for in-house protection according to customer data based on
check lists per variation and device type. Programming of the device configuration in house is
included.

HPTCON 02
Creation of the device configuration for the protection, logic and single line in-house. The
configuration will be effected after customer clarification according to customer data based per
variation and device type. Programming of the device configuration in house is included.

HPTCON 03
Programming of the device configuration per device in-house.

3. HighPROTEC Accessories
Cables for PC - device communication
COMPS232Nullm RS232 Zero Modem Cable with Handshake (3m)
5450-1946 Cable Standard USB-A Male to 5-POLE USB-B Mini Male 1.8M (EDS)

HPTDF1 HighPROTEC distance frame


HPTDF11 Frame for B1 housing 60mm depth
HPTDF12 Frame for B2 housing 60mm depth

URTD Universal Resistor Temperature Box


URTD 01 Up to 12 sensors, PT100, Ni120, Cu10, 48-240 VAC / 48-240 VDC
URTD 02 Up to 12 sensors, PT100, Ni120, Cu10, 24-48 VDC

HPTURTDCON Fibre Optic Cable URDT


1M Fiber optic cable 1 m
2M Fiber optic cable 2 m
5M Fiber optic cable 5 m
10M Fiber optic cable 10 m
20M Fiber optic cable 20 m

HPTTERMKIT Terminal Kits HighPROTEC for pre Wiring


HPTTERMKIT 1 For devices MRI4 / MRM4
HPTTERMKIT 2 For devices MRU4
HPTTERMKIT 3 For devices MRA4D / MRMV4A / MCA4D
HPTTERMKIT 4 For devices MRDT4
HPTTERMKIT 5 For devices MCDGV4 / MCDGV4B / MCDTV4B

58 Woodward
Manual 25182 Energy Controls Product Information

8—Electro-Hydraulic Governors & Actuators


Part Number
Non- Replaced By
Preferred (CE Compliant)
1. TG Turbine Governors
TG13 Screw SS, 2400 rpm 8516-038 9904-814
TG13 Screw SS, 2400 rpm B8516-038 9904-815
TG13 Screw SS, 2400 rpm C8516-038 9904-816
TG13 Screw SS, 4000 rpm F8516-039 9904-820
TG13 Screw SS, 4000 rpm G8516-039 9904-821
TG13 Screw SS, 6000 rpm J8516-040 9904-822
TG13 Screw SS, 6000 rpm H8516-040 9904-823
TG13 Lever SS, 2400 rpm B8516-041 9904-824
TG13 Lever SS, 2400 rpm C8516-041 9904-817
TG13 Lever SS, 4000 rpm C8516-042 9904-818
TG13 Lever SS, 4000 rpm D8516-042 9904-819
TG13 Lever SS, 6000 rpm B8516-043 9904-825
TG13 Lever SS, 6000 rpm C8516-043 9904-826
TG13M (motor speed setting) 8516-167
TG17 Screw SS, 2400 rpm 8516-044 9904-800
TG17 Screw SS, 2400 rpm B8516-044 9904-801
TG17 Screw SS, 2400 rpm C8516-044 9904-802
TG17 Screw SS, 4000 rpm 8516-045 9904-803
TG17 Screw SS, 4000 rpm B8516-045 9904-804
TG17 Screw SS, 4000 rpm C8516-045 9904-805
TG17 Screw SS, 6000 rpm C8516-046 9904-806
TG17 Screw SS, 6000 rpm D8516-046 9904-807
TG17 Lever SS, 2400 rpm 8516-047 9904-808
TG17 Lever SS, 2400 rpm A8516-047 9904-809
TG17 Lever SS, 4000 rpm 8516-048 9904-810
TG17 Lever SS, 4000 rpm A8516-048 9904-811
TG17 Lever SS, 6000 rpm 8516-049 9904-812
TG17 Lever SS, 6000 rpm A8516-049 9904-813

Part
Number
TG611
TG to TG611 Conversion Kit 8516-174
TG611-13, Screw, 2400 rpm, CCW, ATEX, w/ OTD 8516-175
TG611-13, Screw, 2400 rpm, CW, ATEX, w/ OTD 8516-176
TG611-13, Screw, 2400 rpm, CW, ATEX, w/ OTD 8516-177
TG611-13, Screw, 2400 rpm, CCW, ATEX, w/ OTD 8516-178
TG611-13, Screw, 4000 rpm, CCW, ATEX, w/ OTD 8516-179
TG611-13, Screw, 4000 rpm, CW, ATEX, w/ OTD 8516-180
TG611-13, Screw, 4000 rpm, CW, ATEX, w/ OTD 8516-181
TG611-13, Screw, 4000 rpm, CCW, ATEX, w/ OTD 8516-182
TG611-13, Screw, 6000 rpm, CCW, ATEX, w/ OTD 8516-183
TG611-13, Screw, 6000 rpm, CW, ATEX, w/ OTD 8516-184
TG611-17, Screw, 2400 rpm, CCW, ATEX, w/ OTD 8516-185
TG611-17, Screw, 2400 rpm, CW, ATEX, w/ OTD 8516-186
TG611-17, Screw, 4000 rpm, CCW, ATEX, w/ OTD 8516-187
TG611-17, Screw, 4000 rpm, CW, ATEX, w/ OTD 8516-188
TG611-17, Screw, 4000 rpm, CCW, ATEX, w/ OTD 8516-189
TG611-17, Screw, 6000 rpm, CCW, ATEX, w/ OTD 8516-190
TG611-17, Screw, 6000 rpm, CW, ATEX, w/ OTD 8516-191

Woodward 59
Energy Controls Product Information Manual 25182

2. TGE Turbine Actuators


TGE13, 2400 rpm 9904-110
TGE13, 4000 rpm 9904-111
TGE13, 6000 rpm 9904-112
TGE17, 2400 rpm 9904-113
TGE17, 4000 rpm 9904-114
TGE17, 6000 rpm 9904-115

60 Woodward
Manual 25182 Energy Controls Product Information

3. VariStroke Actuators
VariStroke Selection procedure:
1. Create VariStroke model number by using information from Figure 8-1 below.
2. Use the VariStroke Sizing Tool as necessary to select the correct size cylinder for the
application. The VariStroke Sizing Tool is available from
FTC\\servf10\saleskit\Actuation\VariStroke directory or via e-business.
3. Use the developed VariStroke model number from step #1 and the below VariStroke part
number table to select the correct internal VariStroke part number. Note that the estimated
delivery time for part numbers that already exist is 8-10 weeks.
4. If an internal VariStroke part number does not exist for the required model number, then
contact Levi Smith or Rich Kamphaus to have a part number created. Note that the estimated
delivery time for part numbers that do not yet exist in the below table is 12+ weeks.

Figure 8-1. VariStroke Model Number Information

Woodward 61
Energy Controls Product Information Manual 25182

Table 8-1. VS-I Double-Acting Integrated Models

62 Woodward
Manual 25182 Energy Controls Product Information

Table 8-2. VS-I Double-Acting Remote Servo Kit Models

Woodward 63
Energy Controls Product Information Manual 25182

Table 8-3. VS-II Double-Acting Integrated Models w/ Bottom Mount Holes

64 Woodward
Manual 25182 Energy Controls Product Information

Table 8-4. VS-II Double-Acting Integrated Models w/ Top Mount Holes

Woodward 65
Energy Controls Product Information Manual 25182

Table 8-5. VS-II Double-Acting Remote Servo Kit Models w/ Bottom Mount Holes

66 Woodward
Manual 25182 Energy Controls Product Information

Table 8-6. VS-II Double-Acting Remote Servo Kit Models w/ Top Mount Holes

Woodward 67
Energy Controls Product Information Manual 25182

Table 8-7. VS-I & II Double-Acting Servo Only Models

Table 8-8. VS-I & II Spare Parts Kits

68 Woodward
Manual 25182 Energy Controls Product Information

Part
Number
4. Servo Boosters
Single Cylinder 1 x 1 8901-037
Single Cylinder 2 x 1 8901-051
Tandem Cylinder 1 x 1 8901-065
Tandem Cylinder 2 x 1 8901-067
Two-stage Cylinder 2 x 1 8901-091
Two-Stage Cylinder 3 x 1 8901-103

5. CPC Current-to-Pressure Converter


CPC-II - 10 bar, Div.2 (Zone2) 9907-1200
CPC-II - 10 bar, Div.1&2 (Zone1&2) 9907-1199
CPC-II - 25 bar, Div.2 (Zone2) 9907-1198
CPC-II - 25 bar, Div.1&2 (Zone1&2) 9907-1197
CPC-II - Dual Redundant, Zone 2, 0-10 bar model 9907-1253  
CPC-II - Dual Redundant, Zone 2, 0-25 bar model 9907-1254
CPC-II - Voith Adapter Manifold 8928-7240
CPC-DX - Dual Redundant Skid, Zone 2, 0-10 bar model 8918-116  
CPC-DX - Dual Redundant Skid, Zone 2, 0-25 bar model 8918-118

CPC-DX Repair Kits 


KIT-CPC REPLACEMENT, 10 BAR, ZONE 2, FOR CPC-DX SKID 8923-1996
KIT-CPC REPLACEMENT, 25 BAR, ZONE 2, FOR CPC-DX SKID 8923-1997
KIT-REPLACEMENT ISOLATION VALVE: RIGHT HAND 8923-2236
KIT-REPLACEMENT ISOLATION VALVE, LEFT HAND 8923-2242
KIT-PRESSURE GAUGE, 10BAR, FOR CPC-DX SKID 8923-2237
KIT-PRESSURE GAUGE, 25BAR, FOR CPC-DX SKID 8923-2238
KIT-SHUTTLE VALVE, FOR CPC-DX SKID 8923-2239

Part
Number

6. EM Electric Actuators
EML100 Actuator, 1.5” Linear, Single Feedback 9907-779
EM-300 Actuator 8256-109

Suitable EL/LQ Driver Replacement


EM/LQ Driver P/Ns 8200-176, 8200-177, 8200-314, & 8200-319 can be replaced by any of these
DVP P/Ns (see page 27):
8200-505, IP30, Ethernet, TB
8200-507, IP30, TB option
8200-506, IP56, Ethernet
8200-508, IP56, conduit option
Note: Evaluate your application and select the suitable DVP driver that fits the environment. Please
consult with a Woodward Application Engineer if there are any questions or concerns.

7. TM Actuators (Linear)
TM-25LP, Standard, Extends 9907-1213
TM-25LP, Standard, Retracts 9907-1214
TM-25LP, Dual Coil, Extends w/o Feedback 9905-658
TM-25LP, Dual Coil, Retracts w/o Feedback 9905-657
TM-25LP, Dual Coil, Retracts w/ LVDT 9905-659
TM-200LP, Dual Coil, Retracts 9905-773

8. Turbine Shutdown Trip Block Assemblies  


QuickTrip - SIL-3, CV=10, Zone 2 Locations 2-9907-1248
QuickTrip - SIL-3, CV=10, Zone 1 Locations 1-9907-1248

Woodward 69
Energy Controls Product Information Manual 25182

9—Ignition Products
Part
Number
1. Coils
Unshielded Coils
Black 8408-291
Red 8408-591
Blue 8408-501

Shielded Coils
Black 8409-291
Red 8409-591
Blue 8409-501

2. Shielded Harnesses
For IC-92X
Harness, B-Bank, 14 pole, 80" 5417-675
Harness, A-Bank, 17-pole, 80" 5417-673

For TIS-910/IC-910
Harness, B-Bank, 14 pole, 80" 5417-675
Harness, A-Bank, 17-pole, 80" 5417-673

3. Ignition Controllers
IC-920
3-hole gland plate, 20 output (D1 display) 8408-0702
3-hole gland plate, 20 output (J1939, CANopen, E3) 8408-0725
3-hole gland plate, 24 output (D1 display) 8408-0724
3-hole gland plate, 24 output (J1939, CANopen, E3) 8408-0726

IC-922
3-hole gland plate, 20 output (D1 display) 8408-0802
3-hole gland plate, 20 output (J1939, CANopen, E3) 8408-0727

70 Woodward
Manual 25182 Energy Controls Product Information

10—L-Series Actuators and


Integrated Speed Controls
Part
Number
1. L-Series Speed Control–Actuator Only
L-Series Act., Type 6 Shaft, Std Cvr, Spd Ctrl w/o CAN, Dflt Pmtrs 8404-1001
L-Series Act., Type 5 Shaft, Std Cvr, Spd Ctrl w/o CAN, Dflt Pmtrs 8404-1002
L-Series Act., Type 5 Shaft, Std Cvr, Spd Ctrl w/o CAN, Coleman Pmtrs8404-1003
L-Series Act., Type 4 Shaft, Std Cvr, Spd Ctrl w/o CAN, Dflt Pmtrs 8404-1004

2. L-Series Speed Control–Actuator with ITB


L-Series ITB, 25 mm, Spd Ctrl, Dflt Pmtrs 8404-2023
L-Series ITB, 30 mm, Spd Ctrl, Dflt Pmtrs 8404-2006
L-Series ITB, 36 mm, Spd Ctrl, Dflt Pmtrs 8404-2007
L-Series ITB, 43 mm, Spd Ctrl, Dflt Pmtrs 8404-2008
L-Series ITB, 50 mm, Spd Ctrl, Dflt Pmtrs 8404-2009
L-series ITB, 30 mm, Sealed, Spd Ctrl, Dflt Pmtrs 8404-2033
L-series ITB,50 mm, Sealed, Spd Ctrl, Dflt Pmtrs 8404-2052

3. L-Series Process Control with ITB


(AFR is considered a form of Process Control)
L-Series Trim Valve, 16 mm, Process Ctrl, Dflt Pmtrs 8404-3001
L-Series Trim Valve, 22 mm, Process Ctrl, Dflt Pmtrs 8404-3002
L-Series ITB, 25 mm Sealed, Process Ctrl, Dflt Pmtrs, N/C 8404-2061
L-Series ITB, 30 mm Sealed, Process Ctrl, Dflt Pmtrs, N/C 8404-2062
L-Series ITB, 36 mm Sealed, Process Ctrl, Dflt Pmtrs, N/C 8404-2063
L-Series ITB, 43 mm Sealed, Process Ctrl, Dflt Pmtrs, N/C 8404-2064
L-Series ITB, 50 mm Sealed, Process Ctrl, Dflt Pmtrs, N/C 8404-2065
L-Series ITB, 25 mm Sealed, AFR Ctrl, N/O 8404-2048
L-Series ITB, 30 mm Sealed, AFR Ctrl, N/O 8404-2049
L-Series ITB, 50 mm Sealed, AFR Ctrl, N/O 8404-2051

4. L-Series Speed Control–Actuator with ITB & Venturi Mixer (MAS)


L-Series LC50, 25 mm ITB, 27 mm X-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4001
L-Series LC50, 30 mm ITB, 19 mm O-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4002
L-Series LC50, 36 mm ITB, 23 mm O-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4003
L-Series LC50, 43 mm ITB, 29 mm O-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4004
L-Series LC50, 50 mm ITB, 36 mm O-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4005
L-Series LC50, 30 mm ITB, 30 mm X-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4006
L-Series LC50, 36 mm ITB, 34 mm X-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4007
L-Series LC50, 43 mm ITB, 40 mm X-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4008
L-Series LC50, 50 mm ITB, 47 mm X-MIX, MAS, Spd Ctrl, Dflt Pmtrs 8404-4009
L-Series LC50, 25 mm ITB, 27 mm X-MIX, MAS, Pos Ctrl, Dflt Pmtrs 8404-4012

5. L-Series Diesel Engine Applications


L-Series DER, Stanadyne Cvr/Shft, Spd Ctrl w/o CAN, Stana Pmtrs 8404-5003
L-Series DER, Delphi Cvr/Shft w/Lvr, Spd Ctrl w/o CAN, Dflt Pmtrs 8404-5004

6. L-Series Speed Control with ITB & Trim Valve


L-Ser., LC50, 43 mm ITB, 29 mm O-MIX, 22 mm Trim Valve, Dflt Pmtrs8404-4019
L-Ser., LC50, 50 mm ITB, 36 mm O-MIX, 22 mm Trim Valve, Dflt Pmtrs8404-4020
L-Ser., LC50, 50 mm ITB, 47 mm X-MIX, 22 mm Trim Valve, Dflt Pmtrs8404-4021

Woodward 71
Energy Controls Product Information Manual 25182

Part
Number
7. L-Series Positioner with ITB
L-Series Trim Valve, 16 mm, Pos Ctrl, Dflt Pmtrs 8404-3003
L-Series Trim Valve, 22 mm, Pos Ctrl, Dflt Pmtrs 8404-3004
L-Series ITB, 25 mm Sealed, Pos Ctrl, PWM, N/C 8404-2013
L-Series ITB, 30 mm Sealed, Pos Ctrl, PWM, N/C 8404-2014
L-Series ITB, 36 mm Sealed, Pos Ctrl, PWM, N/C 8404-2015
L-Series ITB, 43 mm Sealed, Pos Ctrl, PWM, N/C 8404-2016
L-Series ITB, 50 mm Sealed, Pos Ctrl, PWM, N/C 8404-2017
L-Series ITB, 25 mm Sealed, Pos Ctrl, PWM, N/O 8404-2056
L-Series ITB, 36 mm Sealed, Pos Ctrl, PWM, N/O 8404-2057
L-Series ITB, 50 mm Sealed, Pos Ctrl, PWM, N/O 8404-2058

8. L-Series Accessories
Gasket, 16 & 22 mm, 1/valve 3051-073
Gasket, 25, 30, & 36 mm ITBs 0014-00-034
Gasket, 43 & 50 mm ITBs 0108-00-021
HEGO (Heated Exhaust Gas Oxygen) Sensor 1680-6005
Kit, HEGO Mating Connector 8928-427
Cable, LCS to L-Series Adapter 5450-1033
Kit, L-Series Serial Communication Interface 8923-1061
Kit, L-Series Mating Connector 8928-396
Manifold Air Pressure Transducer 6910-314
Zero Pressure Regulator (for sizes 25, 30, or 36 mm) 0055-00-062
Zero Pressure Regulator (for sizes 43 or 50 mm) 0055-00-063

72 Woodward
Manual 25182 Energy Controls Product Information

11—F-Series Actuator and Actuator with ITB


Part
Number
1. F-Series Positioners
F-Series Actuator, Std Shaft, 23-pin 8235-600
F-Series 33 mm ITB, Std Mount, 23-pin, Plan A 8235-661
F-Series 48 mm ITB, Std Mount, 23-pin, Plan A, Factory Default SW 8235-602
F-Series 48 mm ITB, M08 Mount, 23-pin, Plan A, Factory Default SW 8235-604
F-Series 60 mm ITB, Std Mount, 23-pin, Plan A, Factory Default SW 8235-606
F-Series 60 mm ITB, JADE Mount, 23-pin, Plan A, Factory Default SW 8235-608
F-Series 68 mm ITB, Std Mount, 23-pin, Plan A, Factory Default SW 8235-610
F-Series 68 mm ITB, M10 Mount, 23-pin, Plan D, Factory Default SW 8235-612
F-Series 68 mm ITB, Std Mount, 23-pin, Plan B, Flo-Tech Flow Curve 8235-635
F-Series 68 mm ITB, M10 Mount, 14-pin, Plan A 8235-618
F-Series 48 mm ITB, Std Mount, 14-pin, Plan A 8235-623
F-Series 48 mm ITB, M08 Mount, 14-pin, Plan B 8235-624
F-Series 60 mm ITB, Std Mount, 14-pin, Plan A 8235-625
F-Series 60 mm ITB, JADE Mount, 14-pin, Plan A 8235-626
F-Series 68 mm ITB, Std Mount, 14-pin, Plan A 8235-627
F-Series 68 mm ITB, M10 Mount, 14-pin, Plan A 8235-628
F-Series 48 mm ITB, Std Mount, 14-pin, Plan A 8235-629
F-Series 60 mm ITB, Std Mount, 14-pin, Plan A 8235-630
F-Series 68 mm ITB, Std Mount, 14-pin, Plan A 8235-631
F-Series 60 mm ITB, Std Mount, 14-pin, Plan B 8235-634
F-Series 68 mm ITB, Std Mount, 14-pin, Plan B 8235-639
F-Series 48 mm ITB, Std Mount, 14-pin, Plan B 8235-644
F-Series 48 mm ITB, Std Mount, 23-pin, Plan B, Flo-Tech Sch, N/O 8235-668
F-Series 60 mm ITB, Std Mount, 23-pin, Plan A, Flo-Tech Sch, N/O 8235-669
F-Series 68 mm ITB, Std Mount, 23-pin, Plan A, Flo-Tech Scn, N/O 8235-622

2. Accessories
Kit-F-Series 14-Pin Mating Connector (14-pin kit) 8923-1311
Kit-F-Series 23-Pin Mating Connector (23-pin kit) 8923-1312
Kit-F-Series Communication Hardware, 14 Pin (14-pin kit) 8923-1254
Kit-F-Series Communication Hardware, 23 Pin (23-pin kit) 8923-1255

12—R-Series Actuators
R11 Jumper configurable
R30 Jumper configurable
R11 Toolkit configurable
R30 Toolkit configurable

13—TecJet Fuel Control Valves


TecJet 110 8407-523
TecJet 50 Plus 8407-522 (non-preferred)
TecJet 52 8407-527
TecJet 50 Plus Precision Flow 8407-520
TecJet 85 8407-530

Woodward 73
Energy Controls Product Information Manual 25182

14—Gas Turbine Valves


Part
Number
1. GS6 Gas Fuel Valve Actuator w/ On-board Driver
GS6, 0.30” Port Size, Single Resolver 9908-1536
GS6, 0.45” Port Size, Single Resolver 9908-1540
GS6, 0.60” Port Size, Single Resolver 9908-1544
GS6, 0.75” Port Size, Single Resolver 9908-1552

2. GS16 Gas Fuel Valve Actuator w/ On-board Driver


GS16, 1.0” Port Size, Single Resolver 9908-273
GS16, 1.5” Port Size, Single Resolver 9908-1501
GS16, 2.0” Port Size, Single Resolver 9908-1502

3. GSOV25HT Gas Fuel Shutoff Valve, 2.0” Flange


GSOV25HT w/ 24 Vdc Solenoid, open pos. sw. 9907-894
GSOV25HT w/ 125 Vdc Solenoid, open pos. sw. 9907-895
GSOV25HT w/ 125 Vdc Solenoid, closed pos. sw. 9907-896
GSOV25HT w/ 24 Vdc Solenoid, open & closed pos. sw. 9907-898
GSOV25HT w/ 125 Vdc Solenoid, open & closed pos. sw. 9907-899

4. LQ6 Liquid Fuel Valve Actuator w/ On-board Driver


LQ6, 0.050” Port Size, Single Resolver 9908-1519
LQ6, 0.067” Port Size, Single Resolver 9908-1520
LQ6, 0.150” Port Size, Single Resolver 9908-271

5. LQ25 Standard Valves


LQ25 Valve w/ PIV, w/ SOV, w/ LmtSw, w/o Driver
0.1 in² (requires analog driver) 9908-202
0.2 in² (requires analog driver) 9907-995
0.2 in², 125 Vdc SOV/Switch, 3-speed Resolver (req. digital driver) 9907-652
0.3 in² (requires analog driver) 9907-994
0.3 in², 3-speed Resolver (requires digital driver) 9907-996

6. LSOV25 Liquid Fuel Shutoff Valve


LSOV25, 24 Vdc, 0.5 NPT conduit 9907-997
LSOV25, 24 Vdc, w/ proximity switch 9904-516

7. Electric Actuator/Driver
GS/LQ Analog 9907-135
EM/LQ Digital/Analog (use w/ GAP 3.0 and beyond) 8200-314
EM 24 V Digital 8200-177

74 Woodward
Manual 25182 Energy Controls Product Information

15—Air/Fuel Ratio Controls


Part
Number
1. E3 (All Encompassing Engine and Emission Control)
Full Authority 9908-419
Fuel Blending 9906-720
Lean Burn Trim (AFR only) 8280-1158
Lean Burn Trim (w/ speed control) 8280-1159
Rich Burn (AFR only) 8280-1104
Rich Burn (w/ speed control) 8280-1105

2. Accessories
Universal Exhaust Gas Oxygen Sensor (UEGO) 1689-1032
UEGO Connector Kit 8923-1178
StableSense™ Sensor 1689-1197
StableSense™ Connector Kit 8928-7363
Cam Speed Pickup (M16x1.5) 1689-1114
Cam Speed Pickup (5/8 x 18) 1689-1115
USB to RS-485 Converter 1784-1037
Spare E3 Control Mating Connector Kit 8928-1096

* Reference the specific E3 Control manual for a more detailed list of system accessories.

Woodward 75
Energy Controls Product Information Manual 25182

16—Electronic Accessories
Part
Number
1. Miscellaneous Accessories
Dual Magnetic Pickup Selector (Amplitude Select), High Voltage 8272-310
Dual Magnetic Pickup Selector (Amplitude Select), Low Voltage 8272-311
Dual Magnetic Pickup Selector (Frequency Select), Low Voltage 8272-164

2. Potentiometers
Manual Potentiometer
100 Ω (10 turn, with knob) 5438-737
200 Ω (10 turn, with knob) 5438-739
1 kΩ (10 turn, with knob) 5438-741
2 kΩ (10 turn, with knob) 5461-412
10 kΩ (10 turn, with knob) 5461-559
10 kΩ (10 turn) 1657-659
20 kΩ for 2 to 1 speed adjustment (10 turn) 1657-551
50 kΩ for 3 to 1 speed adjustment (10 turn) 1657-533

Motor Operated Potentiometer


100 Ω, 24 Vdc (3 turn) 8271-752
200 Ω, 24 Vdc (3 turn) 8271-753
1 kΩ, 24 Vdc (3 turn) 8271-754
5 kΩ, 24 Vdc (3 turn) 8272-048
100 Ω, 115Vac (3 turn) 8271-755
200 Ω, 115 Vac (3 turn) 8271-756
1 kΩ, 115 Vac (3 turn) 8271-757
5 kΩ, 115 Vac (3 turn) 8272-277
*Other voltages and ohms available

3. Digital Reference Units


(Replaces Manual Potentiometers and Motor Operated Potentiometers)
Digital Reference Unit/DRU (10–45 Vdc) 8272-682
Digital Reference Unit/DRU (10–45 Vdc)
with Relay Indication 8272-683
Digital Reference Unit/DRU (90–150 Vdc or
88–132 Vac) 8272-684
Digital Reference Unit/DRU (90–150 Vdc or
88–132 Vac) with Relay Indication 8272-685

4. PM Motor Controls
24 Vdc in –> 24 Vdc out 8272-515
115 Vac in –> 0–48 Vdc out 8272-516
230 Vac in –> 0–48 Vdc out 8272-517
110 Vdc in –> 0–48 Vdc out 8272-518

5. Swift Driver
Swift Driver w/ Single Analog Configuration 3522-1016
Swift Driver w/ Dual Analog Configuration 3522-1017

76 Woodward
Manual 25182 Energy Controls Product Information

17—Mechanical-Hydraulic Controls
SG A low-cost, simple, mechanical droop governor for smaller high-speed diesel, gas, and
gasoline engines.
PSG A pressure-compensated, mechanical governor with the stability necessary for droop or
isochronous control of small diesel, gas, or gasoline engines.
UG A rugged, dependable governor commonly used on medium to large diesel, gas,
gasoline, and dual-fuel engines, the UG features isochronous or droop control, dashpot
compensation, and a self contained oil sump.

18—Woodward Authorized Facilities


The Woodward website has a searchable directory of all Woodward plants, offices, distributors, and
other authorized facilities (www.woodward.com/directory.aspx).

19—Repair and Remanufacturing Services


Woodward offers repair and remanufacturing to customers that are authorized to purchase direct.
The spreadsheet below contains pricing for those authorized customers and is not intended to
represent the pricing for our OEM, Channel Partners, Distributors, or Authorized Service facilities.

The Flat Rate pricing program was designed to simply and rapidly process units for our authorized
customer base. Pricing is reviewed quarterly and subject to change without notice.

 All items returned for Repair or Reman options must be in repairable condition.
 Non-repairable and cannibalized items will be subject to replacement at list price less
applicable discounts.
 Pricing does not include conversions from one part number to another, which will be charged
as time and material.
 Pricing does not include repair or warranty evaluation of any pre-production item numbers
[E/C = numeric].
 All applicable charges for expedite, testing, and engineering will apply per Miscellaneous
Charges 5-09-1208.
 Repaired units [mechanical & electrical] carry the ICG standard repair warranty of 180 days.
 Remanufactured and exchange units carry the standard ICG new product warranty of 18
months.
 Once work has commenced, pricing cannot be switched from flat rate to time and material
repair or reman.

Time and Material repairs will be calculated by price of parts and applicable labor rates.

Woodward also offers a Replacement Exchange program to our customers that are authorized to
purchase direct.

 Original invoice or billing will include a core charge in the pricing.


 30 days from shipment of exchange unit, customer must return core for credit.
 Cores returned after 30 days will not be issued core credit
 If core is non-repairable or cannibalized, a core credit will NOT be issued.
 Replacement exchange program is contingent on availability of units.
 Program is designed to support emergency situations where the customer requires an
immediate field replacement.

Woodward 77
We appreciate your comments about the content of our publications.
Send comments to: icinfo@woodward.com

Please reference publication 25182R.

ËB25182:R´¹·¸´¹Î

PO Box 1519, Fort Collins CO 80522-1519, USA


1000 East Drake Road, Fort Collins CO 80525, USA
Phone +1 (970) 482-5811  Fax +1 (970) 498-3058

Email and Website—www.woodward.com

Woodward has company-owned plants, subsidiaries, and branches,


as well as authorized distributors and other authorized service and sales facilities throughout the world.
Complete address / phone / fax / email information for all locations is available on our website.

You might also like