Standard Sewer Detail Drawings

S-1 Standard Bedding for RCP

S-2 Standard Concrete Pavement Patch

S-3 Standard Asphalt Pavement Patch

S-4 Trench Bottom Dimensions & Backfilling Requirements for DIP and RCP

S-5 Trench Bottom Dimensions and Backfilling Requirements for PVC Gravity Sewer Main

S-6 Thrust Blocking Design Data for Sewer Force Main

S-6a Thrust Blocking Design Data for PVC Sewer Force Main

S-7 Standard Thrust Blocking Views

S-8 Standard Main Marker for Sewer Force Mains In Easements

S-9 Standard Sewer Force Main Air Release Valve

S-10 Aerial Pipe Crossing General Notes

S-11 Aerial Pipe Crossing Typical Plans

S-12 Aerial Pipe Crossing Steel Casing Pipe Elevation

S-13 Aerial Pipe Crossing Typical Pipe Section & Elevation

S-14 Aerial Pipe Crossing Concrete Pier

S-15 Aerial Pipe Crossing Pile Cap

S-16 Aerial Pipe Crossing Pile Supported Pier

S-17 Aerial Pipe Crossing Concrete Pier on Bedrock

S-18 Aerial Pipe Crossing Casing Pipe

S-19 Aerial Pipe Crossing Concrete Support

S-20 Standard Pre-cast Sanitary Sewer Manhole

S-21 Extended Bases or Cast-in-Place Reinforced Concrete Base

S-22 Standard Manhole Installation over Existing Sewer Main

S-23 Standard High Velocity Manhole Invert

S-24 Standard Seal Tight Manhole w/ Vented Stack


Standard Sewer Detail Drawings

S-25 Standard Manhole Cover

S-25a Flat Top Manhole Cover

S-26 Manhole Frame and Watertight Cover

S-27 Watertight Manhole Frame with Cam Lock Cover

S-28 Standard Slip Resistant Manhole Step Detail

S-29 Standard Slip Resistant Manhole Step Detail within Paved Surfaces

S-30 Typical Sanitary Sewer Lateral Connection

S-31 Lateral Saddle Installation Detail for PVC Pipe

S-32 Lateral Saddle Installation Detail for VCP and DIP

S-33 Main Extension to Tie into Tee Manhole

S-34 4” Cleanout Plug

S-35 Minimum Requirements for Pump Station (Layout)

S-36 Pump Station Electrical Panel

S-37 Weather Hood for Electrical Equipment Panel

S-38 Typical Sanitary Sewer Service Backwater Valve Installation

S-39 Pipe Alignment Guide (Spiders)

S-40 Oil and Grease Trap Sizing

S-40a Oil and Water Separator

S-41 Oil and Grease Trap Dimensions

S-42 Typical Sewer Service Requiring Backwater Valve

S-43 8” & 10” Sanitary Sewer Easement Widths

S-44 Standard Odor Control Building Front Elevation

S-45 Standard Odor Control Building Side Elevation

S-46 Standard Odor Control Building Floor Elevation

S-47 Standard Odor Control Building Mechanical, Electrical


Standard Sewer Detail Drawings

S-48 Generator Pad

S-49 Concrete Cradle Protection for Sewer Line Crossings

S-50 Standard Vertical Bend

S-51 Aerial Sewer Service

S-52 Wooden Fence Gate

S-53 Inside Drop Manhole


2.5' MIN.
CLASS I,II, OR III MATERIAL
DENSELY COMPACTED
BACKFILL, TAMPED IN 6"
LIFTS

6" MIN.

UNDISTURBED
SOIL
PIPE SPRINGLINE

6" MIN.
CLASS I
MATERIAL

6" MIN. /12" MAX.


WHEN NO TRENCH BOX
REQUIRED (TYPICAL)

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD BEDDING DETAILS FOR


CCFRPM PIPES
DWG. NO. REVISIONS DATE REVISIONS DATE
J.P.S 10-8-10
S-1
NEW CONC. TO BE 3000 PSI SAW CUT AND REMOVE
EXISTING CONC. EXISTING PAVEMENT

1'-0"
TYP.

2" BORE 1 1/8" DIA., 1'-0"


ON CENTER ALONG CUT
6" COMPACTED 1'-0" & DOWEL W/ #4 BAR
1'-0"
NO. 67 STONE TYP. TYP.
EXPANSION JOINT
MATERIAL, MASTIC
BACKFILL, TAMPED
SEALANT, AND DOWEL
IN 6" LIFTS
ADHESIVE AS REQUIRED
BY NCDOT STANDARD SPECS.
SPECS.

PIPE UNDISTURBED SOIL

SEE S-4 & S-5

NOTES:
1. See City of Raleigh standards for trenches and pipe bedding (
S-4 & S-5) for additional details.
2. Pavement cuts over 5'-0" in width shall be reinforced to
N.C.D.O.T. standards.
3. Pavement cuts shall be made with an appropriate saw cut
machine.
4. Pavement cuts within NCDOT ROW shall conform to the approved
on site encroachment permit.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
STANDARD CONCRETE
PAVEMENT PATCH DETAIL
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 6-23-99 A.B.B. 4-19-04
S-2 RRH 3-30-00 J.P.S 10-8-10
NEW ASPHALT SURFACE COURSE
EXISTING PAVEMENT 2" MINIMUM EXISTING PAVEMENT

NEW ABC 12" MIN. DEPTH EXISTING ABC

EXISTING
SUBGRADE 1'-0"

UNDISTURBED SOIL
COMPACTED FILL
IN 6" LIFTS

PIPE

REFER TO S-4
& S-5
NOTES:
1. IN NCDOT MAINTAINED ROADWAYS ENCROACHMENT PAVEMENT PATCH REQUIREMENTS SHALL
TAKE PRECEDENCE.
2. THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT EDGE AND CUT WITH AN APPROPRIATE
SAWCUT MACHINE.
3. THE TRENCH SUBGRADE MATERIAL SHALL BE BACKFILLED WITH SUITABLE MATERIAL AND
COMPACTED TO A DENSITY OF AT LEAST 95% OF THAT OBTAINED BY COMPACTING A SAMPLE OF
THE MATERIAL IN ACCORDANCE WITH AASHTO T-99 AS MODIFIED BY NCDOT.
4. THE FINAL 1' OF FILL SHALL CONSIST OF ABC MATERIAL COMPACTED TO A DENSITY EQUAL TO
100% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH
AASHTO T-80 AS MODIFIED BY NCDOT.
5. THE ENTIRE THICKNESS AND VERTICAL EDGE OF CUT SHALL BE TACKED.
6. THE SAME DEPTH OF PAVEMENT MATERIAL WHICH EXISTS SHALL BE REINSTALLED, BUT IN NO
CASE SHALL THE ASPHALT BE LESS THAN 2" THICK.
7. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY WITH A
SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH LEVEL PATCH.
8. REFER TO CITY OF RALEIGH STANDARDS FOR TRENCHES AND PIPE BEDDING (S-4 & S-5) FOR
ADDITIONAL DETAILS.
9. NO HAND PATCHING ALLOWED.
10. PAVEMENT CUTS WITHIN NCDOT ROW SHALL CONFORM TO THE APPROVED ON SITE
ENCROACHMENT PERMIT.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
STANDARD ASPHALT
PAVEMENT PATCH DETAIL
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 11-1-99 A.B.B. 4-19-04
S-3 RRH 3-30-00 J.P.S. 10-8-10
CL

FINISHED GRADE

FINAL UNDISTURBED SOIL


BACKFILL

2'-0"
INITIAL
BACKFILL

MINIMUM SIDE
6" #67 STONE
6" O.D. OF PIPE 6" CLEARANCE
WHEN ROCK IS
ENCOUNTERED 12" O.D. OF PIPE 12" MAXIMUM SIDE
CLEARANCE
NOTES:
1. TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN FROM THE INSIDE
FACE OF THE SHORING AND BRACING.
2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL.
3. ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL.
4. BACKFILL SHALL BE TAMPED IN 6" LIFTS IN TRAFFIC AREAS, 12" IN NON-TRAFFIC AREAS.
5. ACHIEVE 80% COMPACTION IN NON-TRAFFIC AREAS, AND 95% COMPACTION IN TRAFFIC AREAS.
6. IF IN EASEMENT 4" TOPSOIL, AND 12" CLEAN SELECT FILL MAY BE REQUIRED.
7. NO BOULDERS 8" IN DIAMETER OR GREATER ALLOWED IN FINAL BACKFILL.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

TRENCH BOTTOM DIMENSIONS & BACKFILLING


REQUIREMENTS FOR DUCTILE IRON
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 9-3-99
S-4 RRH 3-30-00
CL
FINISHED GRADE

FINAL
BACKFILL

UNDISTURBED SOIL

2'-0"
INITIAL
BACKFILL

SPRING LINE #67 STONE


HAUNCHING
PIPE GRADE

4" BEDDING

MINIMUM SIDE
TAMP WELL UNDER 6" CLEARANCE
6" O.D. OF PIPE
BOTTOM HALF OF PIPE

TYPICAL TRENCH BOTTOM DIMENSIONS FOR


SDR 35 PVC GRAVITY PIPE
NOTES:
1. FOR TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN FROM THE
INSIDE FACE OF THE SHORING AND BRACING.
2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL.
3. ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL.
4. BACKFILL SHALL BE TAMPED IN 6" LIFTS IN TRAFFIC AREAS, 12" IN NON-TRAFFIC AREAS.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

TRENCH BOTTOM DIMENSIONS AND BACKFILLING


REQUIREMENTS FOR PVC GRAVITY SEWER MAIN
DWG. NO. REVISIONS DATE REVISIONS DATE
TO NOTES 3-1-87 D.W.C. 9-3-99
S-5 7-2-82 RRH 3-30-00
THRUST COLLAR "C"

"D"

"X" BAR UNDISTURBED SOIL


"A"
O.D.
PIPE
"A"

3" MIN.
3" MIN.
"Y" BAR CLEARANCE
CLEARANCE "B"
REINFORCING REQUIREMENTS
I.D. PIPE REBAR SIZE "X" BAR LENGTH "X" BAR WEIGHT "Y" BAR LENGTH "Y" BAR WEIGHT NO. REQUIRED
6" - 36" #5 2'-2"+ O.D. PIPE 1.043 LBS/FT 1'-1" 1.1 LBS. EACH X-24, Y-12
48" & greater #6 3'-0"+ O.D. PIPE 1.502 LBS/FT 1'-3" 1.9 LBS. EACH X-24, Y-12

THRUST COLLAR, AND THRUST SCHEDULE


I.D. PIPE "A" "B" "C" "D"
6" - 16" 1'-4" 1'-7" 2" 3/8"
20" - 24" 1'-4" 1'-7" 3" 1/2"
30" - 36" 1'-4" 1'-7" 4" 5/8"
48" & greater 1'-8" 1'-9" 6" 7/8"

NOTES:
1. CONCRETE SHALL BE 3000 PSI AND TRANSIT MIXED.
2. REINFORCING BARS SHALL BE DEFORMED AND TIED TOGETHER.
3. TRENCH BOTTOM WIDTH IN VICINITY OF THRUST BLOCK INSTALLATION SHALL BE THE
MINIMUM WIDTH AS SHOWN ON STANDARD DETAIL W-3.
4. BACKFILL TAMPED IN 6" LIFTS
PER STANDARD DETAIL W-3.
5. THRUST COLLAR MUST BE FACTORY CITY OF RALEIGH
WELDED ON BOTH SIDES ALONG BOTH DEPARTMENT OF PUBLIC UTILITIES
EDGES OF COLLAR AROUND
CIRCUMFERENCE. RESTRAINING COLLAR DESIGN DATA
FOR SEWER FORCE MAIN
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 1-21-00
S-6 D.H.L. 6-18-08
THRUST BLOCKING

o
45 BEND

TEE INTERSECTION

S-7
D.W.C.
THRUST BLOCK
AREA

DATE DWG. NO. REVISIONS


3-1-87
9-7-99
CITY OF RALEIGH

RRH
NOTES:

D.H.L.
1. CONCRETE SHALL BE 3000 PSI

REVISIONS
o
2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF 90 BEND

DEPARTMENT OF PUBLIC UTILITIES


MECHANICAL JOINT FITTINGS.

STANDARD THRUST BLOCKING VIEWS


3. TRENCHES SHALL CONFORM TO STANDARD DETAIL W-3.
4. SEE STANDARD THRUST BLOCK TABLES, W-10 THRU W-11, FOR
AREA OF CONCRETE REQUIRED.

DATE
5. ALL BENDS AND INTERSECTIONS SHALL HAVE CONCRETE THRUST

3-31-00
6-18-08
BLOCKING.
CENTERLINE OF
MAIN & MARKER

R
A
L
E
I
G
H PLASTIC
4'-6" MARKER
S
E
W
E
R

2'-6"
12" HOLE FILLED
WITH CONCRETE

NOTES:
1. PLASTIC MARKER SHALL
BE GREEN IN COLOR.
2. MARKERS SHALL BE LABELED
"RALEIGH SEWER"
3. TO BE SPACED EVERY 300
FEET ON EACH SIDE OF ANY
ROADWAY OR JUNCTION.
4. MARKERS SHALL BE ROUND
4" IN DIAMETER.

SEWER FORCE MAIN

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD MAIN MARKER FOR


SEWER FORCE MAINS IN EASEMENTS
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 1-21-00
S-8 DHL 6-18-08
NOTE:
NEW MANHOLES USE A BUTYL
SEALANT BETWEEN FRAME AND
MANHOLE TOP SECTION WHEN
SEE C.O.R. STANDARD
SECURING FRAME TO MANHOLE TO
S-25 FOR MANHOLE
PROVIDE A WATER TIGHT SEAL.
FRAME AND COVER

2'-O"
24" MAX

2'-6" MIN.
ECCENTRIC M.H. CONE
MAY BE USED ON 8" , 10"
AND 12" SEWER MAINS.
MANHOLE CONE AND
BARREL SECTIONS SHALL
BE AS PER ASTM.
STANDARDS
4'-6' DIA. AS
REQUIRED
VARIABLE

"O" RING SEAL


1'-4"
TYP.

OR RAM-NECK
4" 4"

SHELF RUBBER BOOT


SLOPE LATERAL INVERT SHALL NOT BE
LOWER THAN MAIN SPRING-
LINE. MANHOLE SHALL BE 2'
6" ABOVE 100 YEAR FLOOD PLAIN
OR SEALED AND VENT TO BE
2' ABOVE 100 YEAR FLOOD
9" PLAIN. WHEN MANHOLE TOPS
ARE IN EXCESS OF 3' ABOVE
SECTION A-A GRADE. OUTSIDE STEPS MUST
BE PROVIDED. SEE STANDARD
S-28 FOR STEP DETAIL. IN
NON TRAFFIC AREAS, TOP OF
FRAME AND COVER SHALL BE
INSTALLED A MIN. OF 1' ABOVE
A A FINISHED GROUND SURFACE.

SEE SEWER DESIGN


SECTION

MIN. 9" COMPACTED #67 STONE


BASE TO BE INSTALLED UNDER
NEW MANHOLE.
CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD PRECAST SANITARY


SEWER MANHOLE
DWG. NO. REVISIONS DATE REVISIONS DATE
Y.C.A. 12-31-92 ABB 2-21-05
S-20 3-30-00
RRH D.H.L. 6-16-08
T2 BARS AT 8" CTS

BILL OF MATERIAL FOR 4' MANHOLE


BAR SIZE LENGTH NO. WT. LBS.

T2 BARS AT 8" CTS


T2 #5 5'-6" 18 103
6'-0" CL. "A" CONCRETE TOTAL CU. YDS. 1,000

6'-0"

REINFORCED CONC. FOOTING FOR


4" PRECAST MANHOLE

T1 BARS AT 8" CTS

BILL OF MATERIAL FOR 4' MANHOLE

BAR SIZE LENGTH NO. WT. LBS.


T1 BARS AT 8" CTS

T1 #5 6'-6" 20 136
7'-0"

CL. "A" CONCRETE TOTAL CU. YDS. 1,361

7'-0"

REINFORCED CONC. FOOTING FOR


5' PRECAST MANHOLE

T2 BARS AT 8" CTS

BILL OF MATERIAL FOR 4' MANHOLE


BAR SIZE LENGTH NO. WT. LBS.
T2 BARS AT 8" CTS

T2 #5 7'-6" 24 165
8'-0"

CL. "A" CONCRETE TOTAL CU. YDS. 1,778

8'-0"
* ALL BASES ARE MINIMUM 9" THICK

REINFORCED CONC. FOOTING FOR


6' PRECAST MANHOLE
CITY OF RALEIGH
T1 OR T2 BAR DEPARTMENT OF PUBLIC UTILITIES

EXTENDED BASE OR CAST-IN-PLACE


STRAIGHT BAR
REINFORCED CONCRETE BASE
DWG. NO. REVISIONS DATE REVISIONS DATE
3-1-87 ABB 2-9-05
S-21
RRH 3-30-00
EXTEND OVER INVERT

EXISTING
GROUT SEWER
MAIN 4"

6"

9"

SECTION AT RIGHT ANGLE TO EXISTING MAIN

S-22
4'-0" FOR 8" TO 12" MAINS
5'-0" FOR 15" TO 30" MAINS
6'-0" FOR 36" TO 54" MAINS

RRH
Y.C.A.
DWG. NO. REVISIONS
NOTES:
1. FLOW SHALL BE MAINTAINED
DURING CONSTRUCTION.
2. THIS DETAIL TO BE USED
GROUT
WHEN A 6" OR LARGER

DATE
LATERAL NECESSITATES

3-30-00
12-31-91
CONSTRUCTION OF A NEW 6" 6"
MANHOLE.
3. SEE STANDARD DETAIL SAW TO CUT SPRINGLINE

CITY OF RALEIGH
S-20, FOR PRECAST MANHOLES.
4. THE CONTRACTOR SHALL

D.H.L.
A.B.B.
REVISIONS
OVER EXISTING SEWER MAIN
PROVIDE A MINIMUM 9" COMPACTED

DEPARTMENT OF PUBLIC UTILITIES


# 67 STONE BASE.

STANDARD MANHOLE INSTALLATION


5. FOR USE ON DIP, CONCRETE, AND PVC ONLY. EXISTING SEWER MAIN
(NOT ALLOWED ON VCP)
SECTION ALONG CENTERLINE OF EXISTING MAIN

DATE
6. SEE DETAIL S-21 FOR REINFORCING OF POURED

1-19-05
6/16/08
IN-PLACE BASE
5.0'

8" D.I. HALF-ROUND

6"
THRU MANHOLE
GROUT GROUT

PRECAST MANHOLE

SECTION AT RIGHT ANGLE TO CENTER LINE OF PIPE

DUCTILE IRON PIPE AND


DUCTILE IRON
BENDS AS NEEDED, WITH
NO MORE THAN THREE
JOINTS OF HALF PIPE.

INVERT SHOULDER DUCTILE IRON


FROM UPSTREAM
6"
DUCTILE IRON MANHOLE
OR PVC TO
DOWNSTREAM SLOPE 10%
MANHOLE OR GREATER
PRECAST
MANHOLE
SECTION ALONG CENTER LINE OF PIPE

NOTE:
NO HORIZONTAL ALIGNMENT CHANGE
CAN BE MADE WITH IN THIS MANHOLE
TYPE. USE ON GRADES 10% OR GREATER.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD HIGH VELOCITY MANHOLE INVERT

DWG. NO. REVISIONS DATE REVISIONS DATE


3-1-87 RRH 3-30-00
S-23
Y.C.A. 12-31-91
* SEE VENT DETAIL

VENT OPENING TO
VENT OPENING TO BE TWO FOOT ABOVE BE SCREENED
HUNDRED YEAR FLOOD ELEVATION
4" "HOT DIPPED"
SEAL AROUND VENT GALV. PIPE
CAM-LOK WATER TIGHT PIPE THROUGH
MANHOLE FRAME AND MANHOLE
COVER CENTERED IN FACTORY CAST IN PLACE
TOP GALVANIZED PIPE FLANGE
12" ABOVE MH TOP
MIN. 12" PRE-CAST
TOP SLAB PROPOSED
GRADE
WALL COLLAR

SLOPE FINISHED GRADE MANHOLE TO


AWAY FROM MANHOLE HAVE CAST IN
ALL SIDES. RISER OPPOSITE
STEPS TO
ACCOMODATE 4"
"HOT DIPPED" FLANGE
GALVANIZED PIPE.

GASKET
3'-0"
HYFE

3'-0"
HYFE

STAINLESS
STEEL BOLTS
VENT DETAIL
* OTHER ACCEPTABLE
COVERS

NOTES: 9" STONE

1. VENT MUST BE FACTORY WELDED CITY OF RALEIGH


FABRICATED AND "HOT DIPPED"
GALVANIZED. DEPARTMENT OF PUBLIC UTILITIES
2.HYFE- Hundred Year Flood STANDARD SEAL TIGHT MANHOLE
elevation WITH VENTED STACK

DWG. NO. REVISIONS DATE REVISIONS DATE


D.W.C. 6-7-99 A.B.B. 4-15-04
S-24 RRH 3-30-00 D.H.L. 6/16/08
COVER 120 LBS. MINIMUM MANHOLE FRAME AND COVER

1"

23 1/2" 21"

2 3/4"
1" VENT HOLE
25 1/16"
23 11/16"
1"

7 1/2" 22"
BUTYL-NEK OR
APPROVED SEALANT
BETWEEN FRAME
AND COVER 1" 25 15/16"
33 1/4"

NOTES: 5/8"X3" LAGSHIELD IN HOLE


1) ALL MANHOLE FRAMES SHALL BE DRILLED INTO CONE OR
DOMESTICALLY CAST. RING WITH ANCHOR SUNK TO
2) FRAME SHALL BE A MINIMUM WEIGHT OF DESIGN DEPTH, AND 3/8"X3"
182 LBS. WITHIN PUBLIC ROW AND 160 LBS. HOT DIPPED GALVANIZED
WITHIN EASEMENTS.
3) COVER SHALL WEIGH A MIN. OF 120 LBS.
LAG BOLT AND WASHER.
4) ALL MANHOLE FRAMES OUTSIDE OF PAVED
SURFACES SHALL BE BOLTED TO THE CONE CITY OF RALEIGH
SECTION OR RING WITH A MINIMUM OF 4
BOLTS PER FRAME.
DEPARTMENT OF PUBLIC UTILITIES

STANDARD MANHOLE COVER


DWG. NO. REVISIONS DATE REVISIONS DATE
3-1-87 3-1-87
S-25
RRH 3-30-00
MINIMUM A/G WEIGHT
FRAME 182
COVER 160
T E R C O N F IN E TOTAL 342
EN D
N OT SP
A

DO

C
E
NG E R
DA
N IT A

RY
SA

R
E W E

ED
PE
MI R
UI

R
T REQ

A
S
U
N
I
E
D
MA

1" LETTERING
RECESSED FLUSH
PLAN

28 1/4"
1" 26 1/4"
26"

7 1/2" GASKET IN VERTICAL


22" FACE OF COVER

RING MUST BE
ANCHORED IN
3" 28"
ACCORDANCE
1" 34" WITH S-25

5/8" o
STAINLESS STEEL ROD

TYPICAL LIFTING DEVICE SECTION A

TOP OF COVER CITY OF RALEIGH


DEPARTMENT OF PUBLIC UTILITIES

MANHOLE FRAME AND WATERTIGHT


COVER
DWG. NO. REVISIONS DATE REVISIONS DATE
3-1-87 3-1-87 ABB 8-29-05
S-26 RRH 3-30-00 D.H.L. 6/18/08
NOTE: WHEN WATERTIGHT NOT SPECIFIED, TOP SHALL
SHALL HAVE ONE 1" VENT HOLE.

27 1/2"
26 1/4"
24 1/16"
1 3/8"

24 1/2" 7 1/2"

28 3/16"
34"
5/8" FRAME SECTION
(2) SS ROLL PINS
(2) CAM LOCKS 1/2" DIA x 1 3/4"
3 7/8"
5/8"
5/16" 9/16"
26"
1 5/8" 2 7/8"
1 3/8"
WIPER GASKET
3/4"
5/8" SS TYPICAL CAM LOCK MANHOLE
ROD

FINNED GASKET IN VERTICAL FACE BOTTOM OF FRAME


OF COVER TO MAKE WATERTIGHT.
OPEN
POSITION
1 1/4"

BOTTOM OF COVER

CLOSED
LOCKING DEVICE POSITION
FRAME

STANDARD - PENTAGON HEAD S.S.


BOTTOM
OPTIONAL - S.S. HEX HEAD BOLT OF FRAME

TYPICAL LOCKING DEVICE

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

RING MUST BE ANCHORED WATER-TIGHT MANHOLE FRAME


IN ACCORDANCE WITH S-25 WITH CAM LOCK COVER
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3-30-00
S-27 DHL 6-18-08
4"

5"

A
SIDE
PLAN ELEVATION
SLIP RESISTANT CLEATS

12"

#3 OR #4 REBAR

CORROSION RESISTANT MATERIAL


RUBBER, PLASTIC

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
SECTION A - A STANDARD SLIP RESISTANT
MANHOLE STEP DETAIL
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3-30-00
S-28
A CT UR
NU F ER
MA
MI T R
PE R EQ
R

GE

UI
DAN

RE
D
TER
CON

EN
FI
ED
OT
N
SP A N
CE DO

2'-0" 3000 P.S.I. CONCRETE


TYP. ENCASEMENT

ADJUST FLUSH PLAN


WITH FINAL GRADE STANDARD MANHOLE
FRAME AND COVER

2"

Min.
8"
A.B.C.
STANDARD
MANHOLE COMPACTED
BACKFILL
TOTAL
CHIMNEY NOT
TO EXCEED 11"

SECTION
PRECAST CONCRETE SPACER
(DONUT RINGS) IN TRAFFIC
AREAS ONLY. DONUT RINGS
NOT ALLOWED IN
EASEMENTS.
CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD MANHOLE FRAME AND COVER


DETAIL WITHIN PAVED SURFACES
DWG. NO. REVISIONS DATE REVISIONS DATE
12-31-91 ABB 9-20-04
S-29 Y.C.A.
RRH 3-30-00 DHL 11-29-07
*SERVICE LATERAL MATERIAL AS REQUIRED
PAVEMENT OPTION
MUST BE 2" BELOW GRADE

WHEN SEWER CLEAN OUT IS IN


PAVEMENT OR IMPERVIOUS SURFACE,

PROPERTY
IT MUST BE INSTALLED INSIDE A VALVE LINE CAST IRON OR BRONZE
BOX (OR MINI-MANHOLE) WITH COVER
CLEAN OUT PLUG
4' DIAMETER CONCRETE LABELED "SEWER".
FINISHED
COLLAR 6" THICK
GRADE

PAVEMENT CURB INSTALLATIONS BY


UTILITY CONTRACTORS
BEYOND THE PROPERTY
OR EASEMENT LINE

S-30
NOTE: REQUIRE A "PLUMBING
THE FULL LENGTH OF THE SERVICE DITCH SHALL UTILITY" PERMIT AND ARE
BE COMPACTED IN 6" LIFTS WITH MECHANICAL TAMP. INSPECTED BY THE

RRH
PLUMBING INSPECTOR.

Y.C.A.
ALL TAPS WILL BE MADE USING MECHANICAL TAPPING DO NOT BACKFILL PRIOR
MACHINE. FOR PVC INSTALLATIONS, SADDLE AND BEND TO INSPECTION.

DWG. NO. REVISIONS


MUST BE BEDDED IN #67 STONE. BEDDING AND HAUNCHING
OF PIPE BARREL MUST COMPLY WITH REQUIREMENTS OF
DETAILS S-4 OR S-5 ACCORDING TO PIPE MATERIAL. 4" D.I. OR
8",10" OR 12" TAPPING PVC PIPE
1 PIECE OF PIPE
SADDLE OR IN-LINE WYE

DATE
1/16" OR 1/8" BEND

6-92
MIN. GRADE 1%

3-30-00
CITY OF RALEIGH

D.H.L.
1.O' EXTENSION

LATERAL CONNECTION
A.B.B.
BARREL OF PIPE BEDDING

REVISIONS
(CLASS II, III, OR IV) WITH PERMANENT
SADDLE

TYPICAL SANITARY SEWER


EXISTING PLUG CAP

DEPARTMENT OF PUBLIC UTILITIES


MAIN FOR SADDLE INSTALLATION
COMBINATION WYE
DETAILS, SEE STANDARD
AND 1/8 BEND
DETAIL S-31 & S-32.

DATE
(ONE PIECE)

4-8-04
6-18-08
FL
O
W
PVC TO D.I. PIPE ADAPTER -
USE 'FERNCO COUPLING
445-401' OR APPROVED
EQUAL TO SEAL.

45 PVC SADDLE

PIPE CROWN

FLOW

STAINLESS
STEEL
CLAMPS

BACKFILL UNDER PVC SADDLE,


ADAPTOR, AND CAST IRON BEND
WITH#67 STONE AS SHOWN ON
S-4.
LE

E
D

DL

PIPE CROWN
AD

AD

o
45o
S

LC S

45
CL

CL PIPE SPRINGLINE

C
L

SADDLE INSTALLATION LIMITS CITY OF RALEIGH


DEPARTMENT OF PUBLIC UTILITIES

LATERAL SADDLE INSTALLATION


DETAIL FOR PVC PIPE
DWG. NO. REVISIONS DATE REVISIONS DATE
3-1-87
S-31 RRH 3-30-00
A

PIPE CROWN
o
45 45o

SADDLE
ASPHALTUM
PAINT
COATED

A PIPE
TAPERED SPIGOT ASTH A-4B SPRINGLINE
PROJECTING 1/2" CLASS CAST
IRON
BEYOND O.D. OF FA
SC G EP CT
MAIN H.
AD AS O OR
XY Y
AP KET AP
40 TE ED
R P PL
PV IE
C VC D
PI

S-32
PE

ASTM C-361-77
RUBBER TUBULAR
GASKET SUPPLIED
CEMENTED TO
SADDLE

RRH
DWG. NO. REVISIONS
SPOT WELDED

3-1-87
FLOW 2.5"

FL
O
W

45o CAST IRON

DATE
SADDLE

3-1-87
3-30-00
PIPE CROWN

TYPE C304 STAINLESS


STEEL T-BOLTS

CITY OF RALEIGH
TYPE C304 STAINLESS FLOW
24 GA. TYP. C304L NUTS AND WASHERS

REVISIONS
STAINLESS STEEL
STRAP

DEPARTMENT OF PUBLIC UTILITIES


NOTE: SADDLE TO BE

FOR VCP AND DUCTILE IRON PIPE


GENECO E40 OR EQUAL

DATE
LATERAL SADDLE INSTALLATION DETAIL
VENT

1' MIN. GROUND ELEVATION

PUBLIC
SEWER CORED
MAIN EXT. HOLE
WITH
RUBBER
BOOT

VARIES
DEPTH
C
L

6.0'
MIN.

C
L CL

1. HOLE SHALL BE CORED IN RISER SECTION FOR PUBLIC SERVICE MAIN EXTENSION.
2. RUBBER BOOT SHALL BE UTILIZED ON ALL CORES
3. CORES SHALL BE IN CENTER OF RISER SECTION
4. CONNECTION TO TEE MANHOLE MUST BE MADE BY CONTRACTOR APPROVED
BY CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
MAIN EXTENSION TO TIE INTO
TEE MANHOLE
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 6-99 ABB 2-14-05
S-33 RRH 3-30-00 D.H.L. 6-18-08
4.00"

STANDARD 4" BRONZE CLEANOUT PLUG

CLEANOUT FERRULE WITH PLUG

STYLES ACCEPTED:
INVERTED NUT
RAISED NUT

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

4" CLEANOUT PLUG


DWG. NO. REVISIONS DATE REVISIONS DATE
3-1-87 RRH 3-30-00
S-34 D.W.C. 3-27-98
GRAVITY MAIN
SIZE & LOCATION
PUMP STATION
EASEMENT MAY VARY

5' BUFFER BETWEEN FENCE AND EASEMENT


(ALL SIDES)
X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X
4' 3' CLEARENCE
CLEARANCE ELECTRICAL
PANEL
RTU ANTENNA POLE

GENERATOR
LOCATION SHALL BE
FIELD DETERMINED.
PUMP
STATION

FENCE
PUMPS
ODOR
CONTROL

SEWER EASEMENT
12' GATE

AREA LIGHT TO BE

SIZE & LOCATION


SIZE & LOCATION
GRAVEL ENTIRE FIELD DETERMINED

FORCE MAIN
AREA INSIDE FENCE

MAY VARY
MAY VARY
X X X X X X X X X X X X X X X X

YARD HYDRANT
24'

TURN
ACCESS DRIVEWAY AROUND
LOCATION MAY VARY

12'

20' ACCESS EASEMENT


LOCATION MAY VARY.
R.O.W. ODOR CONTROL SITES
RPZ IN ABOVE REQUIRE ACCESS FOR 18
GROUND HEATED BOX WHEEL TANKER.

WATER METER
NOTES:
1. PUMP STATION MUST MEET ALL
ZONING SET-BACK REQUIREMENTS
2. PUMP STATION MUST MEET ALL
LANDSCAPING REQUIREMENTS
3. WATER SRVICE FOR YARD HYDRANT
MUST HAVE RPZ BACKFLOW PROTECTION. * FOR ELECTRICAL PANEL
SIZE OF SRVICE MAY VARY REFER TO DETAILS S-36 & S-37
4. PUMP STATION EASEMENT TO BE 60'x
60' MINIMUM
5. EQUIPMENT LOCATIONS MAY VARY CITY OF RALEIGH
6. 5' BUFFER SHALL BE REQUIRED DEPARTMENT OF PUBLIC UTILITIES
BETWEEN FENCE AND EASEMENT
LINE.
MINIMUM REQUIREMENTS FOR
PUMP STATIONS
DWG. NO. REVISIONS DATE REVISIONS DATE
S-35 D.W.C. 10-1-99 A.B.B. 2-16-05
RRH 3-30-00
ALARM LIGHT H/W

WORK LIGHT

WIRE RACEWAY OPT.

DISCONNECT

DISCONNECT
FUSABLE

FUSABLE
MAIN DISCONNECT
SERVICE PANEL W/

MAIN
PS
CB
RTU DISC
SCADA
AUTOMATIC
30" W x 36" H
TRANSFER
SWITCH
SEAL WITH xfmer
SILICONE
METER
480 3ph
120/240 1ph BASE
WEATHERPROOF Meter base
SWITCH FOR LIGHT can be mounted on
2" PVC FOR GFCI PROTECTED back
COAXIL WEATHERPROOF
DUPLEX RECEPTICLE

#4 COPPER
GROUND
ALUMINIUM POSTS (3 REQUIRED)
6" "I" SHAPE, COAT BOTTOM 4'
WITH BITUMINOUS PAINT

6" CONCRETE STANDING

COPPER CLAD DRIVEN


3/4" x 10' COPPER OR
PAD EXTEND 6" PAST

FINISHED GRADE
RAIN HOOD ALL SIDES
4'

GROUND
3000 P.S.I.
CONCRETE

*NOTES*
1. BACKING PLATE TO BE 1/4" ALUMINUM. MOUNT TO "I" BEAM POSTS WITH STAINLESS STEEL NUT,
BOLTS, AND WASHERS.
2. ALL ELECTRICAL WORK SHALL CONFORM TO LATEST NATIONAL, STATE AND LOCAL CODES AND
REQUIREMENTS.
3. SHOW CONDUIT SIZE AND RUNS WITH WIRE SIZE AND NUMBER ON PUMP STATION PLANS.
4. PANEL LAYOUT IS SCHEMATIC ONLY. ADJUST AS NEEDED TO ACCOMMODATE EQUIPMENT.
MAINTAIN 4" MIN. CLEARANCE BETWEEN PANELS AND SIDE SHIELDS.
5. ALL ENCLOSURES SHALL BE NEMA 4X RATED AND LOCKABLE.
6. ENCLOSURES SHALL BE MOUNTED TO ALUMINUM BACKING PLATE WITH NYLON SPACERS &
STAINLESS STEEL NUTS, BOLTS & WASHERS.
7. CONDUIT SHALL BE RIDGID ALUMINUM
OR GALVANIZED. MEYERS HUBS SHALL
BE USED AT ALL PANEL CONNECTIONS.
8. NO EQUIPMENT SHALL BE MOUNTED LESS * FOR WEATHER HOOD REFER
THAN 36" ABOVE FINISHED GRADE. MIN. TO DETAIL S-37
CLEARANCE FROM WORK LIGHT TO STANDING
PAD SHALL BE 6' 6".
CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
PUMP STATION
ELECTRICAL PANEL
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 10-7-99 LBN 10-19-04
S-36 RRH 3-30-00
SIZ
ES
4' AM
BA E A
CK S
ING EQ
BO UIPM
SEE AR EN
D T
NOTE 4
12"

1" FLANGE

"BREAK" TO
"
12

5' - 6"
INSURE RIGIDITY
1" FLANGE

6' - 0"
2" DRIP EDGE

NOTES:
1. HOOD TO 12 Ga. MILL FINISH ALUMINIUM 2.
HOOD TO BE HELIARC "STITCH" WELDED TO 1/4"
ALUMINIUM PLATE EQUIPMENT BACKING BOARD
3. HOOD SHALL BE SAME WIDTH AS ALUMINIUM
PLATE EQUIPMENT BACKING BOARD
4. PROVIDE MOUNTING TABS FOR WORK LIGHT BOX

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
WEATHER HOOD FOR
ELECTRICAL EQUIPMENT PANEL
DWG. NO. REVISIONS DATE REVISIONS DATE
D.W.C. 10-7-99 LBN 9-30-04
S-37
RRH 3-31-00
TYPICAL SANITARY SEWER SERVICE BACKWATER VALVE STYLES:
SCREWCAPS

FLOW
FLOW FLOW FLOW

FLAPPER VALVE

TYPICAL BACKWATER VALVE INSTALLATIONS:

HOUSE

BASEMENT OR CRAWL SPACE

YARD/VAULT INSTALLATION FOR


HOUSE BUILDINGS BUILT ON SLAB AND
OTHER LOCATIONS WHERE VALVE
CANNOT BE INSTALLED IN
BASEMENT OR CRAWL SPACE.
CBSO 4 METER BOX
OR SIMILAR BOX/VAULT
OF APPROPRIATE SIZE
TO ALLOW REGULAR
MAINTENANCE

NOTES:

1. INSTALLATIONS OF GREATER THAN 4' IN DEPTH MAY REQUIRE MANHOLE.

2. VALVES MUST BE INSTALLED IN A LOCATION AT WHICH THEY CAN BE


CLEANED AND SERVICED REGULARLY.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

TYPICAL SANITARY SEWER SERVICE BACK-


WATER VALVE INSTALLATION
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3-31-00
S-38
CARRIER PIPE

3/8" STEEL PLATE, TYP


3/8"x4" STEEL
PLATE, TYP

5/8" A325 BOLT

CASING PIPE

3/16 4

1" RAD ON ALL CORNERS

NOTE:
1) USE A MINIMUM OF TWO SPIDERS PER PIPE JOINT ONE
FOURTH OF THE PIPE JOINT LENGTH IN FROM BOTH THE BELL
AND SPIGOT ENDS.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

PIPE ALIGNMENT GUIDE

DWG. NO. REVISIONS DATE REVISIONS DATE


RRH 3-31-00
S-39 A.B.B. 4-16-04
8" W/ 6/5/4"
BOOT
8" 24" 24" 24"

PRECAST BAFFLE
4" THICK

ADJUSTED TO SOLID RING & COVER,


FINISHED GRADE

OPEN OPEN
3"
OUTLET
INLET
1 DEPTH
4

BAFFLE 2 3 TO 3 4 OF
TOTAL LENGTH
1 DEPTH
2

4"

LENGTH

NOTES:
1. REINFORCEMENT: H-20 BRIDGE
LOADING (TRAFFIC RATED) CITY OF RALEIGH
2. CONCRETE: 4000 PSI @28 DAYS DEPARTMENT OF PUBLIC UTILITIES
3. EARTHCOVER: 0' TO 5' MAX.
1000 GALLON GREASE INTERCEPTOR
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3/9/00 D.H.L. 6/18/08
S-40 ABB 3/19/04
PRECAST BAFFLE
4" THICK

8" W/ 6/5/4"
BOOT
8" 24" 24" 24"

ADJUSTED TO SOLID RING & COVER,


FINISHED GRADE

OPEN OPEN
3"
OUTLET
INLET

1 DEPTH
4

1 DEPTH
2

4" 4"

1 L 1 L 1 L
3 3 3

LENGTH

NOTES:
1. REINFORCEMENT: H-20 BRIDGE CITY OF RALEIGH
LOADING (TRAFFIC RATED) DEPARTMENT OF PUBLIC UTILITIES
2. CONCRETE: 4000 PSI @28 DAYS
1000 GALLON
OIL-WATER-SAND SEPARATOR
DWG. NO. REVISIONS DATE REVISIONS DATE
S-40a RRH 3/9/00 D.H.L. 6/18/08
ABB 3/19/04
LOCALLY AVAILABLE SIZES
INTERCEPTORS SEPARATORS
CAPACITY (GAL.) CAPACITY (GAL.)
300 1000
550 1200
750 1600
1000
1200
1500
2000
2500
3000
4000
5000
6000
8000

NOTES:

1. BAFFLE WALL LOCATED AT A DISTANCE FROM INLET WALL 2 3 TO 3 4 OF THE TOTAL LENGTH
OF THE INTERCEPTOR OR SEPARATOR AS SHOWN ON DETAIL S-40.
BAFFLE WALLS LOCATED AT A DISTANCE APPROXIMATELY OF 13 OF THE TOTAL LENGTH OF THE
SEPARATOR AS SHOWN ON DETAIL S-40.01.
2. EACH INTERCEPTOR OR SEPARATOR SHALL HAVE INLET AND OUTLET TEES. THE OUTLET TEE
SHALL EXTEND 50% INTO THE LIQUID DEPTH. THE INLET TEE SHALL EXTEND 25% INTO THE
LIQUID DEPTH. INLET AND OUTLET TEES MUST BE OPEN TO ALLOW THE COLLECTION OF F.O.G.
SAMPLE.
3. ACESS OPENINGS OVER EACH COMPARTMENT WITHIN THE INTERCEPTOR OR SEPARATOR SHALL
BE 24 INCHES IN DIAMETER AND CONTAIN PICK HOLES. ALL COVERS SHALL BE CONSTRUCTED
OF CAST IRON OR EQUIVALENT TRAFFIC BEARING MATERIAL. MANHOLE COVERS MUST EXTEND
TO FINISH GRADE AND BE INSTALLED TO EXCLUDE THE ENTRANCE OF STORMWATER INTO THE
INTERCEPTOR OR SEPARATOR.
4. FULL SIZE DUAL SWEEP CLEANOUTS SHALL BE INSTALLED ON THE INLET AND OUTLET SIDES
OF THE INTERCEPTOR OR SEPARATOR.
5. INTERCEPTORS AND SEPARATORS MUST BE VENTED IN ACCORDANCE WITH THE NC STATE
PLUMBING CODE.
6. CONCRETE: 4000 PSI @ 28 DAYS.
7. DESIGN: ACI 318 BUILDING CODE
ASTM C1613-06 FOR GREASE INTERCEPTORS
ASTM C913-02 FOR WATER AND WASTEWATER STRUCTURES
ASTM C890-06 FOR MINIMAL STRUCTURAL DESIGN LOADING
8. INTERCEPTORS AND SEPARATORS SHALL BE DESIGNED TO WITHSTAND AN H-20 WHEEL LOAD.
9. INTERCEPTORS OR SEPARATORS MADE OF POLYETHYLENE OR FIBERGLASS SHALL INCLUDE A
MINIMUM 12,000 PSI TENSILE STRENGTH, 19,000 PSI FLEXURAL STRENGTH, AND 800,000 PSI
FEXURAL MODULUS.
10. ALL INTERCEPTORS AND SEPARATORS SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES
DIMENSIONS: GREASE INTERCEPTORS
OIL-WATER-SAND SEPARATORS
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3/9/00 D.H.L. 6/18/08
S-41 ABB 3/19/04
BUILDING WITH NEXT UPSTREAM MANHOLE HIGHER THAN
THE LOWEST DRAIN AND BLOCKAGE IN SEWER MAIN

UPSTREAM
MANHOLE

STREET
SEWER
SERVICE
MANHOLE
FLOW
FLOW

BLOCKAGE
BACKWATER CONDITION INTO BUILDING
WITHOUT BACKWATER VALVE

UPSTREAM
MANHOLE

STREET BACKWATER
SEWER VALVE
SERVICE
MANHOLE
FLOW
FLOW

BACKWATER CONDITION PREVENTED BY


BLOCKAGE BACKWATER VALVE

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

TYPICAL SEWER SERVICE


REQUIRING BACKWATER VALVE
DWG. NO. REVISIONS DATE REVISIONS DATE
RRH 3-31-00
S-42
S

TEMPORARY CONSTRUCTION

(OFFSITE EASEMENTS ONLY)


10' CITY OF RALEIGH

EASEMENT (TYP.)
SANITARY SEWER EASMENT
30' CITY OF RALEIGH

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

8" & 10" SANITARY SEWER


EASEMENT WIDTHS
DWG. NO. REVISIONS DATE REVISIONS DATE
A.B.B. 1-27-05
S-43 D.H.L. 6-18-08
INSULATION
FILL WITH
8" CMU
CONTINOUS RIDGE VENT

3' x 7' 18GA.


INS. STEEL
DOOR
SHINGLES, BLDG.
25 YR. ASPHALT

FELT, 1/2 CDX


PLYWOOD

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD ODOR CONTROL BLDG.


SIDE ELEVATION
DWG. NO. REVISIONS DATE REVISIONS DATE
LBN 10-6-04
S-45
4' - 0"

SLOPE

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD ODOR CONTROL BLDG.


FLOOR ELEVATION
DWG. NO. REVISIONS DATE REVISIONS DATE
LBN 10-6-04
CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

STANDARD ODOR CONTROL BLDG.


MECHANICAL, ELECTRICAL
DWG. NO. REVISIONS DATE REVISIONS DATE
LBN 10-6-04
GEN.

4"

PAD
SIDEWALK CRITICAL GRADE MUFFLER
ALL COMPONENTS STAINLESS
STEEL
1/4" THICK SS WASHER
AND ANCHOR BOLT

SEE DETAIL
CONCRETE PAD W\REBAR
THICKNESS PER MANUF. SPEC

ADD 1\4 " THICK SS WASHERS AT EACH ANCHOR BOLT LOCATION TO PROVIDE
SPACE BETWEEN BASE AND CONCRETE

3' W CONCRETE SIDEWALK ALL SIDES OF UNIT

GENERATOR PAD
PER MANUFACTURERS SPEC.

ANCHOR GENERATOR TO PAD


W/ STAINLESS STEEL ANCHORS
AND 1/4" SS SPACER WASHERS

CONFIRM CONDUIT MAINTAIN 4'


STUB-UP CLEARANCE
PER SHOP DRAWING ALL SIDES

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

GENERATOR PAD
DWG. NO. REVISIONS DATE REVISIONS DATE
L.B.N. 11-19-04
S-48
TOP OF GROUND
STRAP DOWN
THRUST COLLAR SEE S-6
THROUGH S-7 STRAP DOWN

MECHANICAL JOINT
RETAINER GLAND 3/4" THREADED
STEEL RODS

CONCRETE THRUST BLOCK AT SIZE OF BLOCKING


WILL VARY WITH
PIPE SIZE

5' MIN

S-50
5' MIN.
ADD MECHANICAL JOINT
RETAINER GLANDS
THROUGHOUT ASSEMBLY.

ABB
ROD REQUIREMENTS

D.H.L.
DWG. NO. REVISIONS
SIZE OF 45 BEND STATIC THRUST IN POUNDS NO. OF RODS REQUIRED

DATE
4-6-04
6-18-08
GENERAL NOTES:

CITY OF RALEIGH

J.P.S.
REVISIONS
1. STEEL RODS AND BOLTS SHALL BE 3/4" HOT DIPPED GALVANIZED.
2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT BENDS.

DEPARTMENT OF PUBLIC UTILITIES

STANDARD VERTICAL BEND


3. RESTRAINED MECHANICAL GLANDS TO BE USED AT ALL FITTINGS.
4. MUST USE DUCTILE IRON EYE BOLTS WHERE NECESSARY.
5. ALL PIPING IN VERTICAL BENDS MUST BE DUCTILE IRON.
6. PIPE SHALL BE DUCTILE IRON A MINIMUM OF ONE JOINT IN EACH DIRECTION.

DATE
7. 3' MINIMUM COVER MUST BE MAINTAINED ON ALL FORCE MAINS

10-19-10
5' MIN. 5' MIN.

3' MIN. 3' MIN.


SPIDER SEE
DETAIL S-18

FLOW DIRECTION

GROUT CASING 6"


ENDS PER THRUST COLLAR
DETAIL S-18 WELDED TO CASING SEE
12" THRUST COLLAR
1" DRAIN INTO CASING PIPE SEE DETAIL S-18
WELDED TO
WASHED STONE DETAIL S-6 CASING PIPE
REQUIRED AT SEE DETAIL S-6
LOW END

S-51
PROFILE VIEW

J.P.S.
DWG. NO. REVISIONS
6" NOTES:

1. FOR CROSSINGS OF LESS THAN 10' NO CASING IS

DATE
6" 6" REQUIRED IF THE JOINT OF PIPE IS CENTERED ON THE
CROSSING.

10-28-10
2. THRUST COLLAR MAY BE FIELD WELDED ON STEEL
6" CASING SEE CASING PIPE. IF NO CASING IS REQUIRED THE THRUST
DETAIL S-18 COLLAR MUST BE FACTORY WELDED ON DIP CARRIER PIPE.

CITY OF RALEIGH

REVISIONS
CONCRETE COLLAR

AERIAL SEWER SERVICE


DEPARTMENT OF PUBLIC UTILITIES

DATE
INSTALL 1 x 6 BOARDS GATE OPENING = 12'
VERTICALLY, 2 x 6'S MAY SLOPE
OR BE HORIZONTAL TO ACCOUNT LEAF = 6'
FOR GRADE CHANGES. SPACE 1
x 6 BOARDS EQUALLY (3/8" MAX.)
HEAVY DUTY WROUGHT STEEL T-HINGE (TYP.)

8" (TYP.)
HEAVY DUTY DOOR SECURITY SURFACE BOLT

1 x 6 TREATED
WOOD PICKET (TYP.)

OUTSIDE VIEW
N.T.S.

1/8" TENSION WIRE WITH A 3" "EYE & EYE"


TURNBUCKLE, WIRE ROPE THIMBLES AND CLAMPS.
SECURE EACH END OF WIRE WITH SCREW EYEBOLTS.
6 x 6 TREATED WOOD POST (TYP.)
2x4 TREATED WOOD
STRINGER AND BRACE (TYP.) TOENAIL BRACE TO 2 x 6 TREATED WOOD
STRINGER CROSS BRACE (TYP.)

6'-0"

GRADE

1/2" SLOPE PLACE LOWER END OF BRACE TOWARDS


4"
3'-0"

THE HINGE, NOT THE LATCH


CONCRETE FOUNDATION, TYP.
COMPACTED SUBGRADE, TYP.
6" GRAVEL BASE
6"

INSIDE VIEW 4"


N.T.S.

CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

WOODEN FENCE GATE


DWG. NO. REVISIONS DATE REVISIONS DATE
S-52 J.P.S. 3-14-11
CITY OF RALEIGH
DEPARTMENT OF PUBLIC UTILITIES

INSIDE DROP MANHOLE


DWG. NO. REVISIONS DATE REVISIONS DATE
S-53 MAB 11-6-13