These calculations
assume that the end plate is at least as wide.
Reversal
Moment capacity 0.72 Passed
Bolts in shear 0.11 Passed
Tension flange weld 0.84 Passed
Compression flange weld 0.77 Passed Full strength
Web weld tension zone 0.89 Passed Full strength
Web weld shear zone 0.77 Passed Full strength
Tension stiffeners - column side
Stiffener weld 0.21 Passed Minimum 6 fillet weld
Compression stiffeners
Column web fitted N/A Minimum 6 fillet weld
Overall Passed
Bolt capacity
Using Table 3.4 tension resistance of M20 Grade 8.8 bolt
Ft,Rd = k2 fub As / M2 where k2 = 0.90 and fub= 800 N/mm2 See table 3.1
= 0.90 x 800 x 245.0 / 1.25 = 141.1 kN
Bolt row 1
Row 1 alone
And so on...
Calculations for Moment Connections tend to be very lengthy. Full calculations for
all bolt lines are available by selecting Options|Results contents and deselecting
Reduce detail in the Results contents form.
From Figure 6.4 using: = 0.152 and buckling curve 'c' (see Table 6.2)
= 1.000
Equilibrium
Ft,Rd(row) = 573.1 kN.
Fc,Rd = 623.1 kN. Lesser of: 623.1, 652.1, 719.5 /
NEd = -75.3 kN. Negative being compression
Fc,Rd + NEd = 547.8 kN.
Ft,Rd(row) > Fc,Rd + NEd Surplus capacity in bolts. Reduce starting at bottom
row and working up until equilibrium holds
Moment capacity
Row Ftr,Rd hr Ftr,Rd x hr
kN. mm. kN.m.
Ft,Rd(row1) 201.9 651 131.4
Ft,Rd(row2) 200.6 571 114.6
Ft,Rd(row3) 145.4 491 71.4
Ft,Rd(row) = 547.8 Mj,Rd = 317.4
Applied shear
VEd = 380.0 kN.
Bolts in shear
Using Table 3.4 shear resistance of M20 Grade 8.8 bolt
Fv,Rd = v fub A / M2 where v = 0.60 and fub= 800 N/mm2 See table 3.1
= 0.60 x 800 x 245.0 / 1.25 = 94.1 kN.
Calculate thickness factor for full strength double fillet welds SN014a, TC10, P358 Annex C
fy . w . weld 275 x 0.85 x 1.25 from Table 4.1
w
0.0 0.0
Fitted 1196 115 0 82.1 298.5 6FW Passed
201.9 40.9
201.9 30.2
Rib 1196 189 7 193.7 704.5 6FW Passed
200.6 30.2
Partial depth stiffener - Check shear capacity of column web P398 Step 6A
Fv,Rd = 2 x Ls x tw x fy / ( 3 x )
= 2 x 140 x 7.6 x 275 / ( 3 x 1.00 ) = 337.9 kN.
Reversal
Bolt capacity
Using Table 3.4 tension resistance of M20 Grade 8.8 bolt
Ft,Rd = k2 fub As / M2 where k2 = 0.90 and fub= 800 N/mm2 See table 3.1
= 0.90 x 800 x 245.0 / 1.25 = 141.1 kN
From Figure 6.4 using: = 0.142 and buckling curve 'c' (see Table 6.2)
= 1.000
Equilibrium
Ft,Rd(row) = 360.8 kN.
Fc,Rd = 419.2 kN. Lesser of: 483.7, 419.2, 803.1 /
Moment capacity
Row Ftr,Rd hr Ftr,Rd x hr
kN. mm. kN.m.
Ft,Rd(row1) 198.7 651 129.3
Ft,Rd(row2) 162.1 571 92.5
Ft,Rd(row) = 360.8 Mj,Rd = 221.8
Applied moment
MEd = 160.0 kN.
Applied shear
VEd = 75.0 kN.
Bolts in shear
Using Table 3.4 shear resistance of M20 Grade 8.8 bolt
Fv,Rd = v fub A / M2 where v = 0.60 and fub= 800 N/mm2 See table 3.1
= 0.60 x 800 x 245.0 / 1.25 = 94.1 kN.
Calculate thickness factor for full strength double fillet welds SN014a, TC10, P358 Annex C
fy . w . weld 275 x 0.85 x 1.25 from Table 4.1
w
Stiffener Asn,act Fri,Rd m2L Lwt Fs,Ed,1 Fs,Ed,2 Asn Weld Verdict
Frj,Rd m2U (required)
0.0 0.0
Fitted 1435 160 0 81.7 297.0 6FW Passed
198.7 40.2