You are on page 1of 6

AMF PANEL

AMF Panel with Contactor base Auto Changeover


Three Phase for DG Kirloskar/Cummins/Others

Function
Auto main failure panel is used for the automatic operation of the genset. It’s sure to
prov ide you the best effort: monitor the power quality both “MAINS” and “GENERATOR”
automatically, and deliver you the power; on the other side it will monitor the operation
state for both generator and engine while the generator is running. During Abnormal
condition, AMF Panel will shutoff the engine and feedback both the visual and acoustical
signal to you by LED display.
It helps to rotate the starting gear of the genset within 3 seconds after the main supply
is cutoff. It also works in the same manner as manual operation & stops the genset when
the main supply is restored with 5 seconds cool down time. In case of the failure at first
attempt during starting, it will automatically try to restart after the intervals of 12 seconds
for 2 more times, (Total 3 cranking).However, if the gen.does’nt start this time, then an
alarm signal will display on the panel.
It’s sure that whenever the gen. gets started, then the cranking doesn’t take place
again in any case.

Easy Operation
a) AUTO - Push for select of auto mode.
b) MANUAL - Push for select of manual mode.
c) Manual STOP - Push for manual stop. (On Auto & Manual mode)
d) Manual START - Push for manual start. (On Manual mode only)

> Remote facility is also available in AMF Panel for complete operation of generator which
is far away. (Optional)
Features
Sl No. Features
1. Automatic Start the Genset when Mains fails.
2. Automatic Stop the Genset when Mains restores.
3. Automatically Changes the lines from Main AC to Gen Line and vice versa.
4. Protection of controlling Connection with 6 A. MCB only Option 2
5. 6 A. Rotary Switch for By-pass of Mains contactor from VMR. only Option 2
6. Total controlling by Remote switch.
7. Fails- to -start alarm.
8. Automatic Battery Charger inbuilt in AMF unit
9. Start Delay Time 3 sec.
10. Cool down time 40–50 sec.
11. Main restore delay time 10 sec.
12. DG output delay time 8-10 sec.
13. Stop solenoid time 28 Seconds.
14. Cranking time standard – 3 Seconds.
15. Attempt cranking time 20 sec.
16. Total control of safety on DG.
17. 3 Time self Cranking option
18. Low/ high Volt age protection
19. Phase failure protection
20. Phase reverse protection
21. Auto / Manual mode selector available.
22. Digital VAF Meter:- Volt, Amp. Hz. Meters & 4 Indication of Mains & DG in Display
23. Size:- (H X W X D) 675 X 450 X 250 mm
24. Box:- Powder coated, Seemenc gray Color
25. Generat or cranking Relay & Harness are inbuilt
26. 32 A., Contector -
27. 32 A., MCB for Input of Gen. & Main line
28. Very easy installation & operation
29.
AMF Panel with Relay type Changeover

Electronic AMF
Panel (Logic) Engine relay (Booster) Electronic
With BOOSTER
D

D
AUTO
CHANGEOVER
63 Amp. 3 Phase

Technical Detail & Features of AMF Panel (Logic)

· Auto Start the Genset when Mains fails.


· Auto Stop the Genset when Mains restores.
· Total control of safety on DG.
· Total controlling by Remote switch.
· Fails- to -start alarm.
· Auto Battery Charger
· Start Delay Time 3-5 sec.
· Cool down time 30-40 sec.
· 3 Time self Cranking option
· Auto / Manual mode selector available.
· Stop solenoid time 22 sec.
· Cranking time standard
· Attempt cranking time 15 sec.
· Remote facility
S. S. POWER SYSTEM
Works:- 1, R.C. Colony, Bhangel, Phase 2. Noida, G.B. Nager, UP. 201305
Off.:- D -113 , SECTOR -7, NOIDA , G. B. Nager, U.P-201301
Phone: 0120-3252651, 9312835631, 9811422215.
E-Mail:- subtech95@yahoo.co.in
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Date: 22-09-2010

To,
Mr. Srinivas Nistala
Cell Phone : +919441747130 Mail id: designs@e2e-energy.com

Subject : Quotation of AMF PANEL for 10-15 kva DG.


Dear Sir,
With reference to your requirement ofAMF Panel. We appreciate your interest
in AMF are pleased to quote our most competitive rates for the same:

S.No
Product Descriptions Price/unit
1. Complete AMF PANEL (SUBTECH) 22,000.00
Three Phase Auto Changeover, Auto Start & Stop
With 32 A. Contector
(This Panel Suitable for 10-16 KVA DG)
2. Complete AMF PANEL (SUBTECH) 16,000.00
Auto Start & Stop
With 63 A. Relay Base Three Phase Auto Changeover
(This Panel Suitable for 10-15 KVA DG)
3. Installation Charges extra

Terms and Conditions


Sales Tax : Extra @ 12.5 % VAT (Against C Form 2 %)
Payment : 50% advance along with purchase order & balance against delivery.
Warranty : 12 Months.
Delivery : 8-10 Days. (at site)
Transportation cost will be extra
We hope that the above is line with your requirement. Lookin g forward for you valued order now.
Thanking you and assuring you of our prompt services always.

Yours faithfully,
for S.S. POWER SYSTEM

(SUBHASH CHAUHAN)