Professional Documents
Culture Documents
INLET S-301
(PLANT II)
ASD U550 Ii
SAMPLING
POINT ASD SAMPLING
POINT U550 II
U550 I
SAMPLING
POINT U550 I
Resin Performance (After 3rd Regeneration)
Analyzed data: Pilot Plant
26/09/2018-28/09/2018 potential Hydrogen (pH)
10 ASD
16 hours 4
Aldehyde Content 2
U550 I
80 content in lean cycle
U550 II
60
S-301 (Inlet)
water (± 5-9 ppm).
40
ASD resin also help to
20
0
increase the performance
26/09/2018 27/09/2018 28/09/2018 of U550 I in reducing
Date of Aldehydes Analysis aldehydes content.
Resin Performance (After 3rd Regeneration)
Analyzed Data :
Pilot Plant
26/09/2018-28/09/2018
96
UV 220 nm
94
92
% Transmittance
ASD
90
U550 I
88 U550 II
86 S-301 (Inlet)
84
95
ASD ASD also help the
94 U550 I performance of U550 I
93
U550 II for increasing their UV
S-301 (Inlet)
92 Transmittance.
91
Time of Take a Sample
Resin Performance (After 3rd Regeneration)
ASD+U550 Vs Outlet U550 (Plant II)
potential Hydrogen (pH)
UV 220
10
100
9
95
8
% Transmittance
7 90
pH
6 85
5
80
4
75
3
2 70
16:00 0:00 8:00 16:00 8:00 16:00 8:00 16:00 0:00 8:00 16:00 8:00 16:00 8:00
90
Outlet ASD
85 ASD+U550 system is
80 Outlet U550 I (after passing longer than U550 system
from ASD)
75
(now).
S-301 (Inlet lean cycle water)
70
Analyzed data:
16:00 0:00 8:00 16:00 8:00 16:00 8:00
26/09/2018-28/09/2018
Conclusion
• ASD has ability to defend the value of pH at
range 5-8 as long ± 16 hours.
• ASD help the performance of U550 for
increasing their UV Transmittance (220 nm
and 275 nm) and also keep going pH value.
• ASD has “no significant performance” to
increase pH value of lean cycle water.
However, If we use ASD Resin, we have
advantage in reducing aldehydes content in
lean cycle water (± 5-9 ppm).