You are on page 1of 4

Project DEDURUOYA WATER SUPPLY PROJECT

Structure AERATOR

Document Title DESIGN OF PAD FOOTING - F1

DESIGN OF FOOTING - F1

MATERIALS
fcu 30 N/mm² Soil 20 kN/m³
fy 460 N/mm² cover 75 mm
Densities - Concrete 25 kN/m³ Depth 1 m
Bearing pressure 175 kN/m² (Gross allowable)

DIMENSIONS
BASE COLUMN
L= 2.4 m h= 0.45 m
B
B= 2.4 m b= 0.45 m
depth H = 0.45 m

LOADS
Maximum column axial force (SLS) = 731 kN
Weight of Base = 65 kN
Weight of soil = 111 kN
Total Load = 907 kN

Soil Bearing Pressure = 157 kN/m2


ULS pressure due to column load = 184 kN/m2

REINFORCEMENT .
Mxx = 209.9 kNm Myy = 209.9
b= 2400 mm b = 2400
d= 369 mm d = 357
As = 1496 mm² As = 1547
Provide, T 12 @ 150 Provide,T 12 @
As,provided = 1810 mm² As,provided = 1810
As, % = 0.204% As, % = 0.211%
.
SHEAR ACROSS WIDTH OF BASE
Shear span= 975 mm Shear span= 975
4d= 1476 mm 4d= 1428
Shear check @ (l-c)/4 Shear check @ (l-c)/4
Shear at (l-c)/4= 488 mm from col face Shear at (b-c)/4= 488
Vxx = 215.3 kN Vyy = 215.3
v= 0.243 N/mm² v = 0.251
vc = 0.380 N/mm² OK vc = 0.387

PUNCHING SHEAR .
d ave = 363 mm u crit = 6156
As prov = 0.208% V= 624
vc = 0.384 N/mm² v= 0.279
gc 1.5
gs 1.15

b C4

OK

.
kNm
mm
mm
mm²
150
mm²

Vc exceeded
mm
mm

mm from col face


kN
N/mm²
N/mm² OK

Vc exceeded
mm
kN
N/mm² OK