You are on page 1of 3

Pump Performance:According to ISO9906-2012,Grade 2B

Pump Performance Datasheet


Customer Quote number
Customer Reference Pump size KP6020-3/4
Item number Stages 1
Service Based on curve number 1
Quantity of pumps Data last saved 2018-6-28
Operating Conditions Liquid
Flow 430 m3/h Liquid type Water
Head(requested) 80 m Additional liquid description
Head(actual) 80 m Solids diameter,max 0 mm
Suction pressure,rated/max Temperature 20 C
NPSH available,rated Ample m Fluid density,rated/max 1000.00 kg/m3
Frequency 50 HZ Viscosity,rated 1.0 cst
Performance Material
Pump speed,rated 1485 rpm Casing Material CI
Impeller diameter,rated 462.3 mm Impeller Material SS
Impeller diameter,maximum 508.0 mm Pressure Data
Impeller diameter,minimum 355.6 mm Flange Rating PN16
Efficiency 81.97 % Maximum working pressure 0.81 MPa
NPSH 3.3 m Maximum allowable working requested 1.60 MPa
- - Maximum allowable suction pressure limit 0.79 MPa
MCSF 248.80 m3/h Casing hydrostatic test pressure 2.40 MPa
Head Maximum,rated diameter 83.7 m
Driver&Power Data
Head rise to shut off 97.02 %
Driver sizing specification 315M
Flow,best eff.Point(BEP) 496.34 m3/h Margin over specification 1.16
Flow ratio(rated/BEP) 86.63 % Service factor
Head ratio(rated/Max Diameter) 82.45 % Power,hydraulic 93.64 kW
Diameter ratio(ratio/max) 91.00 % Power,rated 114.24 kW
Viscous coefficients(CQ/CH/CE) 1.0/1.0/1.0 Power,maximum 145.75 kW
Selection status Acceptable Min recommended driver 132.00 kW

P(kW)
175

140

105

70

35
0
0 100 200 300 400 500 600 700 800 900 1000

H(m) Eff(%)
120 100

108

96 80

84
508.00mm
72 60

60 462.30mm
48 40

36
355.60mm
24 20

12

0 0
0 100 200 300 400 500 600 700 800 900 1000

NPSH(m) Q(m3/h)
17.5
14.0
10.5
7.0
3.5
0.0
0 100 200 300 400 500 600 700 800 900 1000

Printed from Paco Selector [V3.6.2017-6-30] Motor Sizing Method:ISO 5199


1/3
DIMENSIONS
Split Case Pumps

KP60204 Outline Drawing

YY X HZ HS HD HE HA L W HM
483 432 651 371 371 615 685 2417 448 1185
HR HP n HH HL HB
23 200 6 23 710 1850

SUCTION FLANGE DIMENSION


DN T n d K D
200 41 12 23 295 381
DISCHARGE FLANGE DIMENSION
DN T n d K D
150 37 8 23 240 317.5

Explanation:
1.Flange drilled to:PN16;
2.The rotation direction(viewed from motor to pump)is counterclockwise;
3.Motor:PACO IE3 motor,132kW,4poles,315M;
4.Weight:1798kg;
5.Recommend using DIN 529-A M20?00 foundation bolts;
6.Packaging:Complete package for motor and pump.

Note:All units are in [mm] unless others are stated. 2018-6-28


Printed from Paco Selector [V3.6.2017-6-30]

2/3
DIMENSIONS
Split Case Pumps

KP60203 Outline Drawing

YY X HZ SH DH AE A CP W N
483 432 651 171 171 260 318 994 546 95
D G U BP WS B WB H n b
451 25 53.975 305 394 356 724.5 19 4 12.7
h Ls
59.51 260

SUCTION FLANGE DIMENSION


DN T n d K D
200 41 12 23 295 381
DISCHARGE FLANGE DIMENSION
DN T n d K D
150 37 8 23 240 317.5

Explanation:
1.Flange drilled to:PN16;
2.Weight:640kg.

Note:All units are in [mm] unless others are stated. 2018-6-28


Printed from Paco Selector [V3.6.2017-6-30]

3/3

You might also like