Building Automation
Energy management
Overview
Diagrams
VMU-Y Em2-Server
Server level
Scalable up to Scalable up to
Cloud and
HTTP protocol
FTP protocol
Up to 100 Sites
with Em2-Server
Up to 10 sites
with VMU-Y
RS485 RS485
Up to
Meter
level
32 Energy
Meters and
10 VMU-M
for each
VMU-C EM
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
Em2-Server: Cloud solution for multi-site monitoring
Login page
• Multilingual web based user interface
• User rights management
• Concurrent data access from multiple locations
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
Overview
Energy management
Wound primary CT for cable or CT for cable or CT for cable or CT
CT bus-bar bus-bar bus-bar for cable
• Wound primary • For cable or bus-bar • Split-core for cable or bus-bar • Solid or split-core for cable or • Split-core current sensor for
• Primaries: 1A to 40A (TADK) • Cable: Ø23mm to Ø51mm • Cable: Ø26mm to Ø50mm bus-bar cable
1A to 250A (TADK-2) • Bar: 20x5mm to 64x20mm • Bar: 26x32mm, 50x52mm • Bar: 31x81mm (vertical), • Cable: Ø9.6mm to 20mm
• Secondary: 5A (standard) or 51x43mm • Sealable terminal covers 81x31mm (horizontal) to • Primaries from 60A to 400A
1A (available upon • Sealable terminal covers • Primaries from 100A to 1000A 38x127mm • Secondary: 0.333VAC
request) • Primaries from 50A to 1600A • Secondary: 5A (standard) • Sealable terminal covers • CE, cURus
• Sealable terminal covers • Secondary: 5A (standard) 1A (available • Primaries 150A to 4000A
• CE 1A (available upon request) • Secondary: 5A (standard)
upon request) • IEC61869-2 1A (available
• IEC61869-2 • CE, cURus upon request)
• CE, cURus • IEC61869-2
• CE, cURus
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
Energy management
1-phase energy meters 1-phase energy 1-phase energy 3-phase energy analysers
up to 45A analysers up to 45A analysers up to 100A for direct current up to 65A
• Dimensions: 1 DIN module • Dimensions: 1 DIN module • Dimensions: 2 DIN modules • Dimensions: 3 DIN modules
• Installation: DIN-rail • Installation: DIN-rail • Installation: DIN-rail • Installation: DIN-rail
• Electromechanical totalizer • Backlit touch LCD • Backlit touch LCD • Backlit touch LCD
• Bi-directional energy metering, 7 digits • Measurement of voltage, current, • Display backup by supercapacitor • Measurement of voltage, current,
cl. B (EN50470) power, power factor and frequency • Measurement of voltage, current, power, power factor and frequency
• Measuring inputs: 115/230 VAC, 45A • Bi-directional energy metering, 7 digits power, power factor and frequency • Bi-directional energy metering,
• Self-powered cl. B (EN50470) • Bi-directional energy metering, 8 digits, 3x 8-digit, cl. B (EN50470)
• Pulse output • Measuring inputs: 115/230 VAC, 45A cl. B (EN50470) • Measuring inputs: 208 to 400 VLL AC,
• Sealable terminal covers • Self-powered • Measuring inputs: 115/230 VAC, 100 A 65A
• CE, MID (PFB) • Dual tariff management • Self-powered • Self-powered
• Pulse output or RS485 Modbus or • Dual tariff management • Dual tariff management
M-Bus port • Pulse output or RS485 Modbus or • Pulse output or RS485 Modbus or
• Sealable terminal covers M-Bus port M-Bus port
• CE, MID (PFA and PFB) • Sealable terminal covers • Sealable terminal covers
• CE, MID (PFA and PFB) • CE, MID (PFA and PFB)
• Dimensions: 2 DIN (ET112); 3 DIN (ET340) • Dimensions: 4 DIN modules • Dimensions: 96x96mm • Dimensions: 96x96mm
modules • Installation: DIN-rail • Installation: panel mounting • Installation: panel mounting
• Installation: DIN-rail • Meter for energy from CT 5A or for direct • Energy meter, metering from external • Accuracy 0.2% (voltage, current)
• Measurement of voltage, current, power, energy 65A. External pulse counting inputs, THD measurement. • Universal power supply
power factor and frequency. • Measurement of voltage, current, power, • Measurement of voltage, current, power, • Front protection degree IP65, NEMA4X,
THD (V, A) ET340 power factor and frequency. Metering from power factor and frequency. Metering from NEMA12
• Bi-directional energy metering, 2 tariffs, external sources and 4-tariff management external sources and 4-tariff management • cULus approved, Measurement Canada
cl. 1 (EN62053-1) • Bi-directional energy metering on 2 8-digit • Bi-directional energy metering on 2 8-digit certified
• Measuring inputs: 115/230 VAC, 100 counters, cl. B (EN50470-3) counters, cl. B (EN50470-3) • 16-alarm PLC logic, digital inputs for
A (ET112); 208 to 400 VLL AC, 65 A • Voltage inputs: 3x230(400)VAC • Voltage inputs: 3x230 or 3x100(400)V utility metering, 12 tariffs, event data
(ET340) • Current inputs: 5A, 65A • Current inputs: 5A stamping
• Self-powered • 115-230VAC power supply or self-powered • Power supply 90-260VDC/AC • Modular housing to build the instrument
• RS485 Modbus port (screw, 2x RJ45) • 3 inputs for external dimension counting (IS) • 3 inputs for external dimension counting according to the real application needs
• Optical port • Pulse or relay output: RS485 Modbus RTU, (I3) • Modbus RS485 and Ethernet
• Sealable terminal covers M-Bus • RS485 Modbus RTU, pulse or relay communication ports available
• CE • Sealable terminal covers • Sealable terminal covers
• CE, MID (PF), cULus (5A version) • CE, MID (PF), cULus
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
Energy management
Quick-fit 3-phase 3-phase CT for EM270 Multiple miniature split-core Quick-fit 3-phase
energy analysers for cable or bus-bar current sensor for EM271 energy analysers
• Dimensions: 4 DIN modules or 72x72mm • Dimensions (LxHxP)mm: • Equivalent to Class 1 (currents) of • Dimensions: 4 DIN modules or
• Installation: DIN-rail or panel mounting TCD-1X: 74.84x72x66.80 IEC61869-2 72x72mm
• Two 3-phase energy analysers with sum TCD-2X: 105x72x50 • Primary : 60A (TCD0M), 100A (TCD1M), • Installation: DIN-rail or panel mounting
function TCD-3X: 135x78x50 200A (TCD2M), 400A (TCD3M) • Six 1-phase or two 3-phase energy
• Current measurement by triple CT, solid • Bus-bar sizes (mm): • Hole size: 9.6mm (TCD0M), 15.5mm analysers with sum function
core (EM270), split-core (EM271)with TCD-1X: 15.90x30.48 (TCD1M), 15.5mm (TCD2M), 20.5mm • Current measurement by six channels,
RJ plug TCD-2X: 21.26x25.26 (TCD3M) solid core CT block with RJ plugs
• Quick installation through RJ connectors TCD-3X: 31.25x31.25 • Cable length: 1.8m (TCD0M), 1.5m • Quick installation through RJ connectors
• Automatic recognition of CT ratios • Centre-to-centre distance (mm): (TCD1M and TCD2M), 2.0m (TCD3M) • Automatic recognition of CT ratio
• Measurement of voltage, current, power, TCD-1X: 25 • Auto-detection of the primary current • Measurement of voltage, current,
power factor and frequency, TCD-2X: 35 rated value by the EM271 energy meter power, power factor and frequency,
• Energy metering, cl. 1. TCD-3X: 45 • TCD_M head for wall and DIN-rail • Energy metering, cl. 1.
• Inputs: 3x230(440)VAC, current range • Primary: mounting • Inputs: 3 x 230(440)VAC, 6 x 32A
according to the TCD accessories TCD-1X: 160A • Umbilical connection (80cm) from • Outputs: 2 pulse (loads 1 and 2)
• Outputs: 2 pulse (loads 1 and 2) TCD-2X: 250A TCD_M head to EM271 energy meter • RS485 Modbus RTU
• RS485 Modbus RTU TCD-3X: 630A through RJ11 • CE, cULus
• CE, cULus • CE, UL (with EM270) • CE, UL (with EM271)
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
Energy management
Web server USB dongle Modules Modules
and datalogger connection modules for VMU-C EM for VMU-C EM
Micro PC with datalogger function • Dimensions: 2 DIN modules • Dimensions: 1 DIN module • Dimensions: 1 DIN module
• Web Server, Push and API Pull • Installation: DIN-rail • Installation: DIN-rail • Installation: DIN-rail
• Modbus TCP Slave function • Compatible with Carlo Gavazzi • Connection to VMU-C EM, directly or • Connection to VMU-C EM, directly or
• Data display (charts and tables) approved 3G/4G USB modems through VMU-M EM, on RS485 for through VMU-M EM, on RS485 for
• Data export to HTML compatible with • Power supply 24 VDC (+/- 20%) measurement and state acquisition measurement and state acquisition
Excel and other spreadsheets • Suitable for use with VMU-C and VMU-Y • Measuring inputs: Temperatures, PT100 • Power supply: from the local bus or
• 4GB internal memory, Back-up memory • 3G or 4G Mobile Internet connectivity or PT1000, 1 for current 0-20mA from VMU-M EM
on micro SDHC and USB • SMS alerting • Power supply: from the local bus or • 2 digital inputs
• Energy analysis of each individual load
• SMS commands from VMU-M EM • 2 relay outputs
• Invoicing simulation
• Virtual meter with sum function • CE, cULus • Proprietary communication with • Proprietary communication with
• VMU-W alarm management (e-mail or VMU-C EM or VMU-M EM VMU-C EM or VMU-M EM
SMS) • CE, cULus • CE, cULus
• Power supply: 24VDC
• 1 RS485 for 32 Energy meters,
1 RS485 for VMU-M EM, RJ45 for
Ethernet connection
• CE, cULus
• Dimensions: 2-DIN module; • Virtual machine for energy data • Dimensions: 63 x 46 x 25 mm • Dimensions: 99 x 89 x 30 mm
• Installation: DIN-rail mounting management (without connectors); (without connectors);
• Multi-site monitoring management • Multi-site monitoring management • Installation: DIN-rail and panel • Installation: DIN-rail and panel
• Power supply 24VDC (± 20%) • Flexible and scalable architecture mounting mounting
• 2 USB ports (data /connection backup) • VMware® technology compatibility • 1-phase AC( from 1 to 400 Hz) or DC • 1-phase AC( from 1 to 400 Hz) or DC
• 1 SD port (backup) • Load profile management • Power supply from 9 to 30 VDC • Power supply from 9 to 30 VDC
• Load profile management • Data analysis and benchmark • Contactless Hall effect sensing for • Contactless Hall effect sensing for
• Data analysis and benchmark • Data and event logging current (15 mm hole diameter) current (33 mm hole diameter)
• Data and event logging • Customizable graphical synoptic • True RMS AC and DC monitoring • True RMS AC and DC monitoring
• Customizable graphical synoptic • All data exported in format compatible • Voltage range: 800 VAC, 1000 VDC • Voltage range: 800 VAC, 1000 VDC
• All data exported in format compatible with Excel or other spread sheets • Current range: 50 AAC, 50 ADC • Current range: 300 AAC, 400 ADC
with Excel or other spread sheets • Tariffs and contract management
• Tariffs and contract management • Alarms management
• Alarms management • Database replication from up to 100
• Database replication from up to 10 VMU-C EM
VMU-C EM
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
OUR SALES NETWORK IN EUROPE
AUSTRIA FRANCE ITALY SPAIN
Carlo Gavazzi GmbH Carlo Gavazzi Sarl Carlo Gavazzi SpA Carlo Gavazzi SA
Ketzergasse 374, Zac de Paris Nord II, 69, rue de la Belle Etoile, Via Milano 13, Avda. Iparraguirre, 80-82,
A-1230 Wien F-95956 Roissy CDG Cedex I-20020 Lainate E-48940 Leioa (Bizkaia)
Tel: +43 1 888 4112 Tel: +33 1 49 38 98 60 Tel: +39 02 931 761 Tel: +34 94 480 4037
Fax: +43 1 889 10 53 Fax: +33 1 48 63 27 43 Fax: +39 02 931 763 01 Fax: +34 94 431 6081
office@carlogavazzi.at french.team@carlogavazzi.fr info@gavazziacbu.it gavazzi@gavazzi.es
CHINA
Carlo Gavazzi Automation (Kunshan) Co., Ltd.
Kunshan
HEADQUARTERS
Carlo Gavazzi Automation SpA
Via Milano, 13
I-20020 - Lainate (MI) - ITALY
Tel: +39 02 931 761
info@gavazziautomation.com