You are on page 1of 20

H2 ECOnomy – Your Fuel Cell Experts!

Fuel Cell Test Systems – GCU series Gas Control Units, ELB
series Electronic Load Banks

Liquid Fuel (Methanol, Ethanol, etc.) Supply System – LFS-FC-D

Fuel cell stacks – LightFC-XU™, EcoFC-XU™, ProFC-XR™ and


FC-0XK™ series

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Fuel Cell Test Systems


H2 ECOnomy is pleased to introduce affordable test systems to satisfy your fuel cell testing
needs.

Our Gas Control Units (GCU) and Electronic Load Banks (ELB) can be used separately, or
together as a complete fuel cell test system. Make your choice between three fuel cell power
ranges; 1500W, 500W and 150W, and H2 ECOnomy’s test system will become an
indispensable part of your fuel cell laboratory.

Gas Control Units (GCU)


H2 ECOnomy’s Gas Control Units (GCU) are designed for testing hydrogen/oxygen or
hydrogen/air fuel cells, including the measurement and control of the pressure, mass flow,
temperature and humidity of the H2 and O2 or Air.

GCU features include:

¾ GCU gas control units are equipped with devices for measuring and controlling gas
flow rates, pressures and temperatures, as well as with humidifiers with ramped
heating temperature regulation and a bypass line, allowing operation with or without
humidification.
¾ The hydrogen channel can be set to be purged with specified intervals and duration, to
help avoid flooding of the tested fuel cell when necessary.
¾ GCU is operated and controlled manually, by a dial, knobs and handles on the front
panel. Once set, the system will maintain the gas temperature and humidity
automatically.
¾ The unit has self-diagnostic capabilities to automatically fix some of the possible
failures of its microprocessor program that may occur due to the proximity of powerful
external sources of electromagnetic impulses.
¾ PC interface with RS-232 protocol (through a COM port) to enable reading, displaying
and recording the test data on a personal computer using the National Instruments
LabVIEW™ based Automated User Monitoring Interface (AUMI) software.
¾ Designed to fully comply with safe operation requirements, protecting personnel from
electric shock, fire and explosion.
¾ All sensors in the GCU Gas Control Units are spark-protected to ensure the safe
operation with flammable gases.
¾ A special hydrogen safety sensor to detect the presence of as low as 0.5% of leaked
hydrogen in the unit, with light and sound alarm indication and automatic shutdown.
The Alarm indication is also duplicated in the AUMI software interface.
¾ In case of necessity, both channels can be connected to nitrogen or inert gas supply
source.

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th2


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Gas Control Unit GCU-150

GCU-150 Specifications

Gas temperature control automatic*


Gas humidity control automatic*
Gas pressure control manual
Gas flow rate control manual

Hydrogen yes
Bypass System
Oxygen / Air yes

PCI personal computer interface with Automated User Monitoring Interface (AUMI) software included

Voltage 220 or 110 VAC at choice


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 700 W

Gas input pressure 0.3-0.5 MPa


Gas outlet pressure (from the unit to the fuel cell) 0-0.2 MPa
Hydrogen mass flow rate (to the fuel cell) 0-2 SLPM
Oxygen / Air mass flow rate (to the fuel cell) 0-20 SLPM
Temperature of outlet gases (to the fuel cell) Up to 70 °C
Humidity of outlet gases (to the fuel cell) Up to 95 % ± 5%

Pressure ±0.01 MPa


Hydrogen flow rate ±0.02 SLPM
Measuring Accuracy Oxygen/Air flow rate ±0.2 SLPM
Temperature ±1 °C
Humidity ±5% RH
* Setting these parameters is manual, by the dial on the front panel. However, once set, the system will maintain them
automatically.

Reseller Price: Call

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th3


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Gas Control Unit GCU-500

GCU-500 Specifications

Gas temperature control automatic*


Gas humidity control automatic*
Gas pressure control manual
Gas flow rate control manual

Hydrogen yes
Bypass System
Oxygen / Air yes

PCI personal computer interface with Automated User Monitoring Interface (AUMI) software included

Voltage 220 or 110 VAC at choice


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 2000 W

Gas input pressure 0.3-0.5 MPa


Gas outlet pressure (from the unit to the fuel cell) 0-0.2 MPa
Hydrogen mass flow rate (to the fuel cell) 0-8 SLPM
Oxygen / Air mass flow rate (to the fuel cell) 0-60 SLPM
Temperature of outlet gases (to the fuel cell) Up to 70 °C
Humidity of outlet gases (to the fuel cell) Up to 95 % ± 5%

Pressure ±0.01 MPa


Hydrogen flow rate ±0.08 SLPM
Measuring Accuracy Oxygen/Air flow rate ±0.6 SLPM
Temperature ±1 °C
Humidity ±5% RH
* Setting these parameters is manual, by the dial on the front panel. However, once set, the system will maintain them
automatically.

Reseller Price: CAll

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th4


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Gas Control Unit GCU-1500

GCU-1500 Specifications

Gas temperature control automatic


Gas humidity control automatic
Gas pressure control manual
Gas flow rate control manual

Hydrogen yes
Bypass System
Oxygen / Air yes

PCI personal computer interface with Automated User Monitoring Interface (AUMI) software included

Voltage 220 or 110 VAC at choice


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 3500 W

Gas input pressure 0.3-0.5 MPa


Gas outlet pressure (from the unit to the fuel cell) 0-0.2 MPa
Hydrogen mass flow rate (to the fuel cell) 0-20 SLPM
Oxygen / Air mass flow rate (to the fuel cell) 0-200 SLPM
Temperature of outlet gases (to the fuel cell) Up to 70 °C
Humidity of outlet gases (to the fuel cell) Up to 95 % ± 5%

Pressure ±0.01 MPa


Hydrogen flow rate ±0.2 SLPM
Measuring Accuracy Oxygen/Air flow rate ±2 SLPM
Temperature ±1 °C
Humidity ±5% RH
* Setting these parameters is manual, by the dial on the front panel. However, once set, the system will maintain them
automatically.

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th5


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
Electronic Load Banks (ELB)
H2 ECOnomy's Electronic Load Banks (ELB) are designed to monitor and control the voltage,
current, and power of your fuel cell or another DC power source. These affordable and easy-
to-use load banks come in three modifications; for handling fuel cells up to 1500 W, 500 W
and 150 W.

H2 ECOnomy’s electronic load banks allow testing fuel cells in three different load modes -
Constant Current, Constant Voltage and Constant Power.

PCI personal computer interface with RS-232 protocol (through a COM port) is provided to
enable full control of the load bank from a personal computer using the National Instrument’s
LabVIEW™ based Automated User Control Interface (AUCI) software, as well as to record
and digitally/graphically display the test data.

The PCI also adds the Scan and Duty Cycle testing modes to the unit's capabilities. The Scan
mode allows easy and automatic acquisition of data for polarization curves: the ELB applies
incrementally increasing current values to the tested power source up to a limit set by the user
over a specified period of time. In the Duty Cycle mode a specified load is turned on and off
with a specified duty cycle time and period, which is most useful when activating a fuel cell or
testing its durability.

Safety features include:

- Designed to fully comply with safe operation requirements, protecting personnel from
electric shock, fire and explosion.
- Overheating protection embedded.
- Includes a fuse to protect from surges, spikes and the like in the grid.

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th6


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Electronic Load Bank ELB-150

ELB-150 Specifications

Fuel cell maximum voltage 50 V


Fuel cell maximum current 150 Amps
Fuel cell maximum power 1500W

Current yes
Digital
Voltage yes
Indication
Power yes

Voltage 100 - 240 VAC


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 80 W

PCI personal computer interface with Automated


included
User Control Interface (AUCI) software

Constant Current yes


Constant Voltage via PCI only
Testing Modes Constant Power via PCI only
Scan via PCI only
Duty Cycle via PCI only

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th7


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Electronic Load Bank ELB-500

ELB-500 Specifications

Fuel cell maximum voltage 30 V


Fuel cell maximum current 100 Amps
Fuel cell maximum power 500W

Current yes
Digital
Voltage yes
Indication
Power yes

Voltage 100 - 240 VAC


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 100 W

PCI personal computer interface with Automated


included
User Control Interface (AUCI) software

Constant Current yes


Constant Voltage yes
Testing Modes Constant Power yes
Scan via PCI only
Duty Cycle via PCI only

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th8


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

Electronic Load Bank ELB-1500

ELB-1500 Specifications

Fuel cell maximum voltage 50 V


Fuel cell maximum current 150 Amps
Fuel cell maximum power 1500W

Current yes
Digital
Voltage yes
Indication
Power yes

Voltage 100 - 240 VAC


Power Supply Frequency 50/60 Hz
Power Consumption (max.) 200 W

PCI personal computer interface with Automated


included
User Control Interface (AUCI) software

Constant Current yes


Constant Voltage yes
Testing Modes Constant Power yes
Scan via PCI only
Duty Cycle via PCI only

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th9


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
LFS-FC-D Liquid Fuel Supply Systems NEW!

H2 ECOnomy’s LFS-FC-D liquid fuel supply systems are intended for supplying methanol,
ethanol or other liquid fuels to fuel cells. LFS-FC-D is equipped with devices for measuring
and automatic control of liquid fuel pressure and temperature, manual control of flow rate, as
well as a system for cooling of the unused fuel with either subsequent return to the tank or
discharge to outside.

Technical specifications of LFS-FC-D

Operating voltage - 110/220 VAC


Frequency - 50/60 Hz
Power consumption - up to 1000 W
Methanol outlet pressure
(from the unit to the fuel cell) - up to 3 bar
Methanol flow rate - up to 1000 mLPM, depending on outlet T°
Outlet Methanol temperature - up to 120°С

Measurement Accuracy

Pressure: ±1%
H2 flow rate: ±1%
Temperature: ±1°C

Dimensions - approx. 50 x 20 x 30 cm
Weight - approx. 13 kg

Reseller Price: CALL

Shipping and handling fee for all products is extra.

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th10


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

PEM Fuel Cell Stacks from H2 ECOnomy


LightFC-XUTM

Learn the Technology

LightFC-XU™ is a small, 1 to 4-cell fuel cell designed specifically to demonstrate the potential of fuel
cells. It can be purchased in 0.6, 1.2, 1.8 and 2.4V models that deliver 1.3-8 watts of power, enough to
illuminate a small light bulb. LightFC-XU™ is an excellent starter kit for understanding the inner
workings of fuel cells.

General operational parameters and conditions for LightFC-XU™ series

- Type: Proton Exchange Membrane (Polymer Electrolyte)


- Fuel/Oxidant: Hydrogen / Air or O2
- Maximum output voltage: 0.9 to 1 V per cell
- Maximum gas pressures (each
2 bar (gauge)
channel):
- Allowable pressure difference
0.2 bar
between the two channels:
- Acceptable ambient temperatures: 0 to +50°C
- Stack working temperature: 10 to 70°C
- Optimal working conditions for 99.99% (or more) purity of H2 and O2 gases, 100%
achieving maximum output: humidification, stack temperature 60 to 80°C

LightFC-1U

• Single cell PEM fuel cell


• Expected Power: 1.3 to 2W at 0.6V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 5 cm2
• Membrane area: 12.6 cm2
• Approximate weight: 100 g
• Dimensions: Ø6 x 2.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

LightFC-2U

• Two-cell PEM fuel cell stack


• Expected Power: 2.6 - 4W at 1.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 5 cm2
• Membrane area: 12.6 cm2
• Approximate weight: 150 g
• Dimensions: Ø6 x 3 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th11


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
LightFC-3U

• Three-cell PEM fuel cell stack


• Expected Power: 3.9 to 6W at 1.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 5 cm2
• Membrane area: 12.6 cm2
• Approximate weight: 200 g
• Dimensions: Ø 6 x 3.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

LightFC-4U

• Four-cell PEM fuel cell stack


• Expected Power: 5.2 to 8W at 1.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 5 cm2
• Membrane area: 12.6 cm2
• Approximate weight: 250 g
• Dimensions: Ø 6 x 4 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th12


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

EcoFC-XU™

Power in a Small Package

EcoFC-XU™, available in 1 to 6-cell versions, generates 4.5 to 36 watts at 0.6 to 3.6 V. They are
designed for demonstration and study of fuel cell operation. Although the output voltage increments are
the same as LightFC-XU™, more power is available because the membrane electrode assembly in the
fuel cell has a larger active area. By comparison, this is more power than is normally drawn from a 9 V
battery. EcoFC-XU™ series are straightforward fuel cell stacks, powerful enough to operate small
electronic devices, inexpensive to own and convenient to experiment with.

General operational parameters and conditions for EcoFC-XU™ series

- Type: Proton Exchange Membrane (Polymer Electrolyte)


- Fuel/Oxidant: Hydrogen / Air or O2
- Maximum output voltage: 0.9-1V per cell
- Maximum gas pressures (each channel): 2 bar (gauge)
- Allowable pressure difference between
0.2 bar
the two channels:
- Acceptable ambient temperatures: 0 to +50°C
- Stack working temperature: 10 to 80°C
- Optimal working conditions for achieving 99.99% (or more) purity of H2 and O2 gases, 100%
maximum output: humidification, stack temperature 60 to 80°C

EcoFC-1U

• Single cell PEM fuel cell


• Expected Power: 4.5 to 6W at 0.6V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 650 g
• Dimensions: 9 x 9 x 3 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

EcoFC-2U

• Two-cell PEM fuel cell stack


• Expected Power: 9 to 12W at 1.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 700 g
• Dimensions: 9 x 9 x 3.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th13


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
EcoFC-3U

• Three-cell PEM fuel cell stack


• Expected Power: 13.5 to 18W at 1.8V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 750 g
• Dimensions: 9 x 9 x 4 cm

Reseller Price: CALL

EcoFC-4U

• Four-cell PEM fuel cell stack


• Expected Power: 18 to 24W at 2.4V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 800 g
• Dimensions: 9 x 9 x 4.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

EcoFC-5U

• Five-cell PEM fuel cell stack


• Expected Power: 22.5 to 30W at 3V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 850 g
• Dimensions: 9 x 9 x 5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL-

EcoFC-6U

• Six-cell PEM fuel cell stack


• Expected Power: 27 to 36W at 3.6V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 14.5 cm2
• Membrane area: 36 cm2
• Approximate weight: 900 g
• Dimensions: 9 x 9 x 5.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL-

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th14


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
ProFC-XR™

Lead the Trend

H2 ECOnomy’s ProFC-XR™ series air-hydrogen PEM fuel cells provide maximum power of up to
160W, depending on the model. Designed for demonstration and study of fuel cell operation, these
PEM fuel cell stacks are offered in 1 to 10-cell models. They produce 15 to 160 watts of power at 0.6 to
6.0 VDC. This is more than enough power to keep your notebook computer running. ProFC-XR™
series provide a good model of the systems that are being used in various applications.

Attention: H2 ECOnomy’s ProFC-XU™ series have been replaced by ProFC-XR™. Thanks to the
improved design the new ProFC-XR™ have better performance and are more lightweight. With the
ProFC-XR™ fuel cell stacks you will have more power for the same number of cells and voltage.

General operational parameters and conditions for ProFC-XR™ series

- Type: Proton Exchange Membrane (Polymer Electrolyte)


- Fuel/Oxidant Hydrogen / Air or O2
- Maximum output voltage: 0.9 to 1V per cell
- Maximum gas pressures (each channel): 2 bar (gauge)
- Allowable pressure difference between
0.2 bar
the two channels:
- Acceptable ambient temperatures: 0 to +50°C
- Stack working temperature: 10 to 80°C
- Optimal working conditions for achieving 99.99% (or more) purity of H2 and O2 gases, 100%
maximum output: humidification, stack temperature 60 to 80°C

ProFC-1R

• Single cell PEM fuel cell


• Expected Power: 15 to 20W at 0.6V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.55 kg
• Dimensions: 15.5 x 6.3 x 3.3 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL -

ProFC-2R

• Two-cell PEM fuel cell stack


• Expected Power: 30 to 36W at 1.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.575 kg
• Dimensions: 15.5 x 6.3 x 3.7 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th15


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

ProFC-3R

• Three-cell PEM fuel cell stack


• Expected Power: 45 to 50W at 1.8V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.6 kg
• Dimensions: 15.5 x 6.3 x 4.0 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL-

ProFC-4R

• Four-cell PEM fuel cell stack


• Expected Power: 60 to 67W at 2.4V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.7 kg
• Dimensions: 15.5 x 6.3 x 4.5 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

ProFC-5R

• Five-cell PEM fuel cell stack


• Expected Power: 75 to 85W at 3.0V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.75 kg
• Dimensions: 15.5 x 6.3 x 5.2 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

ProFC-6R

• Six-cell PEM fuel cell stack


• Expected Power: 88 to 100W at 3.6V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.8 kg
• Dimensions: 15.5 x 6.3 x 5.6 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

ProFC-7R

• Seven-cell PEM fuel cell stack


• Expected Power: 100 to 115W at 4.2V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.85 kg
• Dimensions: 15.5 x 6.3 x 6.0 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

ProFC-8R

• Eight-cell PEM fuel cell stack


• Expected Power: 113 to 130W at 4.8V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.9 kg
• Dimensions: 15.5 x 6.3 x 6.7 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL-

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th16


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

ProFC-9R

• Nine-cell PEM fuel cell stack


• Expected Power: 126 to 145W at 5.4V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 0.95 kg
• Dimensions: 15.5 x 6.3 x 7.4 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL,-

ProFC-10R

• Ten-cell PEM fuel cell stack


• Expected Power: 140 to 160W at 6.0V
• Recommended gas pressures: 1 bar for H2/Air or 1.2 bar for H2/O2
• Active area: 40.25 cm2
• Membrane area: 58 cm2
• Approximate weight: 1.0 kg
• Dimensions: 15.5 x 6.3 x 7.8 cm (w/o bolts, fittings, and current collectors)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th17


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
FC-0XK™

Get More!

The hydrogen/air PEM fuel cells FC-019K-5 to FC-05K-15 are our largest commercial stacks, offered
together with cooling fans. Capable of providing power from 185 to 500 W in their optimal operating
conditions, they can be used in laboratory settings or for small stationary and portable systems. Choose
between 5 and 15 cells models and make your first step towards the future hydrogen economy!

General operational parameters and conditions for FC-0XK™ series

- Type: Proton Exchange Membrane (Polymer Electrolyte)


- Fuel/Oxidant Hydrogen/Air
- Maximum output voltage (w/o load): 0.9 per cell
- Recommended gas pressures (gauge): 0.5 to 0.7 bar for both H2 and Air
- Maximum gas pressures (each channel): 1 bar (gauge)
- Allowable pressure difference between
0.1 to 0.3 bar
the two channels:
- Acceptable ambient temperatures: 0 to +50°C
- Stack working temperature: 50 to 70°C
- Stack maximal temperature: Up to 80°C
- Optimal working conditions for
99.99% (or more) purity of H2 gas, 100% humidity of gases
achieving nominal output:

FC-019K-5

• Five-cell hydrogen/air fuel cell stack


• Expected Power: 195W at 3.0V
• Peak Power: 215W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 6.4 kg
• Dimensions: 20 x 20 x 7 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: Euro CALL

FC-023K-6

• Six-cell hydrogen/air fuel cell stack


• Expected Power: 230W at 3.6V
• Peak Power: 250W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 6.6 kg
• Dimensions: 20 x 20 x 8 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL


Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th18
Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy
FC-026K-7

• Seven-cell hydrogen/air fuel cell stack


• Expected Power: 260W at 4.2V
• Peak Power: 285W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 7.6 kg
• Dimensions: 20 x 20 x 9 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-029K-8

• Eight-cell hydrogen/air fuel cell stack


• Expected Power: 290W at 4.8V
• Peak Power: 320W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 7.9 kg
• Dimensions: 20 x 20 x 11 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-032K-9

• Nine-cell hydrogen/air fuel cell stack


• Expected Power: 320W at 5.4V
• Peak Power: 355W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 8.4 kg
• Dimensions: 20 x 20 x 12 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-035K-10

• Ten-cell hydrogen/air fuel cell stack


• Expected Power: 350W at 6.0V
• Peak Power: 390W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 8.6 kg
• Dimensions: 20 x 20 x 13 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-038K-11

• Eleven-cell hydrogen/air fuel cell stack


• Expected Power: 380W at 6.6V
• Peak Power: 425W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 9 kg
• Dimensions: 20 x 20 x 15 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th19


Tel. 02-9792982-3 Fax. 02-9792984 Email: Sale@polysource.co.th
Welcome to H2 Economy

FC-041K-12

• Twelve-cell hydrogen/air fuel cell stack


• Expected Power: 410W at 7.2V
• Peak Power: 460W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 9.4 kg
• Dimensions: 20 x 20 x 16 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-044K-13

• Thirteen-cell hydrogen/air fuel cell stack


• Expected Power: 440W at 7.8V
• Peak Power: 495W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 9.8 kg
• Dimensions: 20 x 20 x 18 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-047K-14

• Fourteen-cell hydrogen/air fuel cell stack


• Expected Power: 470W at 8.4V
• Peak Power: 530W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 10.3 kg
• Dimensions: 20 x 20 x 20 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

FC-05K-15

• Fifteen-cell hydrogen/air fuel cell stack


• Expected Power: 500W at 9.0V
• Peak Power: 520W
• Recommended gas pressures: 0.5 - 0.7 bar gauge for both H2 and Air
• Active area: 132.25 cm2
• Membrane area: 225 cm2
• Approximate weight: 10.6 kg
• Dimensions: 20 x 20 x 22 cm (w/o bolts, fittings, current collectors and fans)

Reseller Price: CALL

Note: Shipping and handling fee for all products is extra.

CONTACTS CONTACTS
H2 ECOnomy, CJSC POLYSOURCE LTD.,PART
10/2 M. Heratsu Street, 3/3 Moo 2, Tiwanon Road
Yerevan, 0025, Armenia Banklang, Muang, Pathumthani
Tel: (+374) 10 570 147 Tel: ( 66 ) 2 979 2982-3
Fax: (+374) 10 570 187 Fax: ( 66 ) 2 979 2984

Copyright © 2002-2009 All rights reserved.


Air & Gases Division - Polysource Ltd. Thailand www.polysource.co.th20