Generator set data sheet

Model: C400 D6
Frequency: 60 Hz
Fuel type: Diesel

Spec sheet: SS9-CPGK


Noise data sheet (open/enclosed): ND50-OS550 / ND50-CS550
Airflow data sheet: AF50-550
Derate data sheet (open/enclosed): DD50-OS550 / DD50-CS550
Transient data sheet: TD50-550

Standby Prime
Fuel consumption kW (kVA) kW (kVA)
Ratings 400 (500) 365 (456)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 7.9 13.2 18.5 24.2 8.8 12.6 17.1 21.8
L/hr 36.0 60.0 84.0 110.0 39.9 57.5 77.8 99.0

Engine Standby rating Prime rating


Engine manufacturer Cummins
Engine model NTA855 G5
Configuration 4 Cycle; in-line; 6 cylinder diesel
Aspiration Turbocharged and after-cooled
Gross engine power output, kWm 451 406
BMEP at set rated load, kPa 2147 1911
Bore, mm 140
Stroke, mm 152
Rated speed, rpm 1800
Piston speed, m/s 9.1
Compression ratio 14:1
Lube oil capacity, L 34.1
Overspeed limit, rpm 2100 ±50
Regenerative power, kW 22
Governor type Electronic
Starting voltage 24 Volts DC

Fuel flow
Maximum fuel flow, L/hr 213
Maximum fuel inlet restriction, mm Hg 203
Maximum fuel inlet temperature, °C 70

power.cummins.com
©2017 Cummins Inc. | DS73-CPGK (08/17)
Air Standby rating Prime rating
3
Combustion air, m /min 37.70 34.00
Maximum air cleaner restriction, kPa 6.2

Exhaust
3
Exhaust gas flow at set rated load, m /min 107.1 99.0
Exhaust gas temperature, °C 535 508
Maximum exhaust back pressure, kPa 10.2

Standard set-mounted radiator cooling


Ambient design, °C 50
Fan load, kW m 19
Coolant capacity (with radiator), L 45
3
Cooling system air flow, m /sec @ 12.7 mm H2O 7.2
Total heat rejection, Btu/min 15125 13613
Maximum cooling air flow static restriction mm H2O 19.1

Weights* Open Enclosed


Unit dry weight kgs 3493 5041
Unit wet weight kgs 3683 5818
* Weights represent a set with standard features. See outline drawing for weights of other configurations.

Dimensions Length Width Height


Standard open set dimensions mm 3549 1100 2115
Enclosed set standard dimensions mm 5110 1563 2447

Genset outline
Open set

Enclosed set

Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.

power.cummins.com
©2017 Cummins Inc. | DS73-CPGK (08/17)
Alternator data
Connection Temp rise ºC Duty Alternator Voltage
Wye, 3 Phase 125/105 S/P HC5C 416-480 V
Wye, 3 Phase 150/125 S/P HC5E 380-480 V

Ratings definitions
Emergency Standby Limited-Time Running Prime Power (PRP): Base Load (Continuous)
Power (ESP): Power (LTP): Power (COP):
Applicable for supplying Applicable for supplying Applicable for supplying Applicable for supplying
power to varying electrical power to a constant power to varying electrical power continuously to a
load for the duration of electrical load for limited load for unlimited hours. constant electrical load for
power interruption of a hours. Limited-Time Prime Power (PRP) is in unlimited hours. Continuous
reliable utility source. Running Power (LTP) is in accordance with ISO 8528. Power (COP) is in
Emergency Standby Power accordance with ISO 8528. Ten percent overload accordance with ISO 8528,
(ESP) is in accordance with capability is available in ISO 3046, AS 2789,
ISO 8528. Fuel stop power accordance with ISO 3046, DIN 6271 and BS 5514.
in accordance with AS 2789, DIN 6271 and
ISO 3046, AS 2789, DIN BS 5514.
6271 and BS 5514.

Formulas for calculating full load currents:

Three phase output Single phase output

kW x 1000 kW x SinglePhaseFactor x 1000


Voltage x 1.73 x 0.8 Voltage

For more information contact your local Cummins distributor


or visit power.cummins.com

©2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of
Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice.
DS73-CPGK (08/17)