Options
Indoor unit
Kit nam e
Name of optio n Remar k
FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
High-e 1 65% KAFP632B80 KAFP632B160
90% KAFP633B80 KAFP633B160
Filter chamber(for rear suction) 1 KDDFP63B80 KDDFP63B160
1 KAFP631B80 KAFP631B160
Service pane l White KTBJ25K80W KTBJ25K160W
Fresh white KTBJ25K80F KTBJ25K160F
Brown KTBJ25K80T KTBJ25K160T
Air discharge adapto r KDAP25A71A KDAP25A140A
Shield plate for side plate KDBD63A160
Remote controlle r Wireless type Cooling only(RZR) BRC4C66
Heat pump(RZQ) BRC4C65
Wired type 2 BRC1C61
Navigation Remote Controlle r Wired type 2 BRC1E62
Adaptor for wiring KRP1C64
Wiring adaptor for electrical appendices (2) KRP4AA51
Remote senso r KRCS01-4B
Mounting plate for adaptor PCB. 3,4,5 KRP4A98
Central remote controller 6 DCS302CA61
6 DCS301BA61
Schedule timer 6 DST301BA61
intelligent Touch Controller 6 DCS601C51
Note: 1If installing high e 4
2 5
Wiring for wired remote controller to be procured locally. Only one mounting plate can be installed for each indoor unit.
3 6
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Outdoor unit
Kit name
RZR50LVVM RZR125LVVM RZQ100KCTLT RZQ100LUYLT
Name of optio n
RZR60LVVM RZR100LVVM RZQ125KCTLT RZQ125LUYLT
RZR71LVVM RZR140LVVM RZQ140KCTLT RZQ140LUYLT
Central drain plug KKP014A4 KKPJ5G280 KKPJ5F180
Fixture for preventing overturning ---------- KKTP5B112 KPT-60B160
---------- K-KYZP15C
Demand adaptor ---------- KRP58M51
Refrigerant branch piping kit For twin multi ---------- KHRP58P216T ----------
2nd Floor Hanston Square, 17 San Miguel Ave, Ortigas Center, Pasig City, 1605
Tel. No (02) 942 - 6800 / 942 - 6792 Fax: (02) 942 - 6793
installation flexibility With a height of only 245 mm, installation is Adjustable external static pressure
work
possible even in buildings with narrow ceiling
spaces Drain pan maintenance check window
50 Pa 150 Pa
This makes it possible to inspect for drain pan dirt
Set to low static Set to high static pressure for the use of tools.
245 mm
pressure when ducts advanced needs such as when
are short. using dampers and long ducts.
700 mm
Interlock Simultaneous air conditioning of two rooms
Bottom suction is available and ventilation grille (ventilation opening)
Door-installed Wall-installed
ventilation grille ventilation grille Under-door cutout
Clean
Control box Switch bottom plate with
cover Bottom Air suction
plate
Make the control box Bottom plate
face inward.