Specifications

50 60 71 100 125 140 125 140


PLSPH1527
Model Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE FBQ60EVEx 2 FBQ71EVEx 2
Name Outdoor unit RZR50LVVM RZR60LVVM RZR71LVVM RZR100LVVM RZR125LVVM RZR140LVVM RZR125LVVM RZR140LVVM
Power supply Indoor unit 1 Phase, 220 V, 60 Hz
Outdoor unit 1 Phase, 220–230 V, 60 Hz
Cooling capacity 1, 2 5.0 6.0 7.1 10.0 12.5 14.0 12.5 14.0
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.)
Power consumption 1 Cooling 1 kW 1.39 1.69 2.22 2.82 3.73 4.71 3.73 4.71
COP W/W 3.60 3.56 3.20 3.55 3.35 2.97 3.35 2.97
Fan (H/M/L) m3/min 18/15/12.5 23/19.5/16 32/27/22.5 36/30.5/25 18/15/12.5 23/19.5/16
Indoor
unit cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 635/530/441 812/688/565
External static pressure 3 Pa Rated 50 (50-150)
Sound pressure level (H/M/L) 4 dB(A) 35/33/31 38/35/33 38/35.5/33 40/37.5/35 35/33/31 38/35/33
Dimensions (H X W X D) mm 245 X 1,000 X 800 245 X 1,400 X 800 245 X 1,000 X 800
Sound pressure Cooling dB(A) 48 49 50
Outdoor
level 4 Nigth quiet mode dB(A) 44 45 46 45 46
unit
Dimensions (H X W X D) mm 595 X 845 X 300 990 X 940 X 320 1170 X 900 X 320

100 125 140 100 125 140


Model Indoor unit FBQ100EVE FBQ125EVE FBQ140EVE FBQ100EVE FBQ125EVE FBQ140EVE
Name Outdoor unit RZQ100KCTLT RZQ125KCTLT RZQ140KCTLT RZQ100LUYLT RZQ125LUYLT RZQ140LUYLT
Power supply Indoor unit 1 Phase, 220 V, 60 Hz
Outdoor unit 3 Phase, 220 V, 60 Hz 3 Phase, 380 V, 60 Hz
Cooling capacity 1,2 Cooling 10.0 12.5 13.3 10.0 12.5 13.1
kW (5.0-11.4) (6.0-14.3) (6.2-15.8) (5.0-11.4) (6.0-14.3) (6.2-15.8)
Rated (Min. - Max.)
Power consumption Cooling 1 kW 3.13 3.96 4.22 3.13 3.96 4.22
COP kW 3.19 3.16 3.15 3.19 3.16 3.15
Indoor
unit
Fan (H/M/L) m3/min
cfm
32/27/22.5
1,130/953/794
36/30.5/25
1,271/1,077/883
32/27/22.5
1,130/953/794
36/30.5/25
1,271/1,077/883 FBQ50EVE / FB60EVE / FBQ71EVE
External static pressure 3 Pa Rated 50 (50-150)
Sound pressure level (H/M/L) 4
Dimensions (H X W X D)
dB(A)
mm
38/35.5/33 40/37.5/35
245 X 1,400 X 800
38/35.5/33 40/37.5/35
FBQ100EVE / FBQ125EVE / FBQ140EVE [60 Hz]
Sound pressure Cooling dB(A) 49 50
Outdoor
level 4 Nigth quiet mode dB(A) 45
unit
Dimensions (H X W X D) mm 1170 X 900 X 320
Note: 1Rated cooling capacities are based on the following conditions: Indoor temp., 27 °C DB, 19.0 °C WB; outdoor temp. 35 °C DB , 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
5
iency(gravity method)50% or more.

Options
Indoor unit
Kit nam e
Name of optio n Remar k
FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
High-e 1 65% KAFP632B80 KAFP632B160
90% KAFP633B80 KAFP633B160
Filter chamber(for rear suction) 1 KDDFP63B80 KDDFP63B160
1 KAFP631B80 KAFP631B160
Service pane l White KTBJ25K80W KTBJ25K160W
Fresh white KTBJ25K80F KTBJ25K160F
Brown KTBJ25K80T KTBJ25K160T
Air discharge adapto r KDAP25A71A KDAP25A140A
Shield plate for side plate KDBD63A160
Remote controlle r Wireless type Cooling only(RZR) BRC4C66
Heat pump(RZQ) BRC4C65
Wired type 2 BRC1C61
Navigation Remote Controlle r Wired type 2 BRC1E62
Adaptor for wiring KRP1C64
Wiring adaptor for electrical appendices (2) KRP4AA51
Remote senso r KRCS01-4B
Mounting plate for adaptor PCB. 3,4,5 KRP4A98
Central remote controller 6 DCS302CA61
6 DCS301BA61
Schedule timer 6 DST301BA61
intelligent Touch Controller 6 DCS601C51
Note: 1If installing high e 4
2 5
Wiring for wired remote controller to be procured locally. Only one mounting plate can be installed for each indoor unit.
3 6
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

Outdoor unit
Kit name
RZR50LVVM RZR125LVVM RZQ100KCTLT RZQ100LUYLT
Name of optio n
RZR60LVVM RZR100LVVM RZQ125KCTLT RZQ125LUYLT
RZR71LVVM RZR140LVVM RZQ140KCTLT RZQ140LUYLT
Central drain plug KKP014A4 KKPJ5G280 KKPJ5F180
Fixture for preventing overturning ---------- KKTP5B112 KPT-60B160
---------- K-KYZP15C
Demand adaptor ---------- KRP58M51
Refrigerant branch piping kit For twin multi ---------- KHRP58P216T ----------

2nd Floor Hanston Square, 17 San Miguel Ave, Ortigas Center, Pasig City, 1605
Tel. No (02) 942 - 6800 / 942 - 6792 Fax: (02) 942 - 6793

notice. c All rights reserved 06/15 SS


Thinner design Design and installation Using a DC fan motor, the external static Easy maintenance
pressure can be controlled to within a range of
allows greater flexibility 50 Pa to 150 Pa Position of drain pan inspection opening
has been modi ed for easier inspection

installation flexibility With a height of only 245 mm, installation is Adjustable external static pressure
work
possible even in buildings with narrow ceiling
spaces Drain pan maintenance check window
50 Pa 150 Pa
This makes it possible to inspect for drain pan dirt

Set to low static Set to high static pressure for the use of tools.

245 mm
pressure when ducts advanced needs such as when
are short. using dampers and long ducts.

such as duct length. Inspection


One of the industry’s most compact opening for
drain pan
bodies in the mid-static pressure range.
Ai rate auto adjustment function Drain pan
maintenance
check window
Indoor unit 71E 100/125/140E
run.
Height (mm) 245 It is automatically adjusted to approximately ±10% of the
Easy maintenance because the drain pan
Width (mm) 1,000 1,400
can be removed
Depth (mm) 800

Interlock control by outside system


Higher lift is realized by utilising built-in DC Enables control by hotel key card system acting as master
drain pump with standard accessory ON/OFF for room electricity.

Enables central control of room ventilation and lighting by


High efficiency
third-party building management system. DC fan motor and DC drain pump are
utilised to improve energy e ciency
Middle & High static
850 mm pressure type
(FBQ-D series)

700 mm
Interlock Simultaneous air conditioning of two rooms
Bottom suction is available and ventilation grille (ventilation opening)

When air conditioning two rooms simultaneously,


unit joist the air discharged into each room must be
circulated back to the air conditioner. To achieve
DIII-NET communication standard this, a ventilation duct should be installed for each
Air suction room or one of the indicated ventilation grilles
Easier communication and connection with the centralised
ceiling
control system. should be installed on the partitioning wall or under
the door between the rooms.
Wiring and servicing can be done from the underside of the
unit (an option part required).

Rear suction Bottom suction


Comfort Ventilates air through
Partitioning wall
Sield plate for side plate(option)
Switchable fan speed:High/Middle/Low and Auto the partitioning wall.
(See below)
(“Auto” is applicable when BRC1E62 is used.)

Door-installed Wall-installed
ventilation grille ventilation grille Under-door cutout

Clean
Control box Switch bottom plate with
cover Bottom Air suction
plate
Make the control box Bottom plate
face inward.

Silver ion anti-bacterial drain pan


Ventilation grille Ventilation grille Under-door cutout
A built-in antibacterial treatment that uses silver ion in the
drain pan prevents the growth of slime, bacteria, and mould Note: The under-door cutout method should be used only when
that cause smells and clogging.
Control box cover
Control box faces outward. Control box faces inward.