You are on page 1of 6

Scenario: Replacing Two OMUa or OMUb Boards with Two OMUc

Boards
This section describes how to replace two OMUa or OMUb boards with two OMUc boards.

Prerequisites

 You have logged in to the LMT. For detailed operations, see Logging In to and Logging Out of the
LMT.
 Two new OMUc boards are ready.

Context

Mixed—insertion of OMU Boards


 Short-term mixed—insertion of OMU boards is supported. When an OMUc board is used to
replace an OMUa/OMUb board, the OMUc board and the OMUa or OMUb board can be
inserted into the slots and co-exist for a short period, so that data can be transferred from the
OMUa or OMUb board to the OMUc board.
 Long-term mixed—insertion of OMU boards in slots is not supported because the active and
standby OMU boards must be of the same type for commercial delivery in existing network, for
example, both active and standby OMU boards must be OMUa boards or OMUc boards.

NOTICE:
To protect the OMU board from the Electrostatic Discharge (ESD), wear an ESD wrist strap and insert its
connector into the ESD socket on the cabinet before replacing the board. For detailed operations, see
Wearing an ESD Wrist Strap. If an ESD wrist strap or ground point is unavailable, wear a pair of ESD
gloves instead.

Procedure

1. Run the DSP OMU command to query information about the OMU and record the queried
information in Records of the product software Installation Information.
Record Sheet of OMU Software Installation Information of the OMU board to be replaced
records the following information:
 Administrator password
 Password of system administrator admin
 Password of FTP user FtpUsr
 External fixed IP address, external virtual IP address, internal fixed IP address, internal
virtual IP address, debugging IP address, and backup channel IP address of the OMU
board

NOTE:
This document uses the OMUa board as an example.
2. Stop the omud process on the standby OMU board and shut down the OMU operating system
(OS).
a. Log in to the standby OMU. For detailed operations, see Logging In to the OMU in the
BSC6900 GSM OMU Administration Guide.
b. Run the /etc/rc.d/omud stop command to stop the omud process.
c. Run the poweroff command to shut down the OMU OS.
3. Remove the standby OMU board. For detailed operations, see Replacing an OMU board that is
equipped with new ejector levers or Replacing an OMU board that is equipped with old ejector
levers.
4. Install the OMUc boards in the active and standby slots of the board. These slots are green in
Figure 1.
The OMUa or OMUb board is twice the thickness of other boards. Two OMUa or OMUb boards
are installed in the slots in blue, yellow, and red frames, as shown in Figure 1. Between two
adjacent OMUa or OMUb boards, one is active and the other is standby.
The first OMUc board used for replacement must be installed in the green slots.
Example 1: Two OMUa boards are installed in the slots 20 through 23 before replacement.
Slots 20 and 21 house the active OMUa board. Slots 22 and 23 house the standby OMUa
board. Perform the following operations to replace OMU boards:
. Remove the OMUa board installed in slots 22 and 23.
a. Install the first OMUc board in slot 23.
Example 2: Two OMUa boards are installed in the slots 20 through 23 before replacement.
Slots 20 and 21 house the standby OMUa board. Slots 22 and 23 house the active OMUa
board. Perform the following operations to replace OMU boards:
b. Remove the OMUa board installed in slots 20 and 21.
c. Install the first OMUc board in slot 21.
Figure 1 Slots housing the first OMUc board

5. Connect the PC and the ETH2 port on the OMUc board using the network cable.
6. Set the IP address of the PC to be on the same network segment with the ETH2 port. The
initial IP address of the ETH2 port is 192.168.6.50 or 192.168.6.60, the subnet mask is
255.255.255.0.
7. Uploading the OMU application installation package to the OMU. For details, see Uploading
the Product Software Installation Package to the OMU in the BSC6900 GSM OMU
Administration Guide.
8. Logging in to the OMU.
. Run the SSH terminal, for example, PuTTY, on the PC, and type the debugging IP
address of the OMU.
a. Logging in to the OMU. For detailed operations, see Logging In to the OMU in the
BSC6900 GSM OMU Administration Guide.
9. Installing the product software in the active workspace.
. Navigate to the directory where the OMU application installation package is saved.
Assume that the product software installation package install_bam.sh is saved in
/mbsc/upgrade/V***R***C**/install/setup. Enter the following command:
cd /mbsc/upgrade/V***R***C**/install/setup
a. Enter chmod +x ./install_bam.sh to obtain the permission to run ./install_bam.sh.
b. Enter ./install_bam.sh.
c. The system prompts you to type the product running mode. Type the product running
mode and press Enter.
d. [2011-05-03 10:12:32] software integrality verify begin...
e. [2011-05-03 10:12:42] software integrality verify end...
f.
g. # The run mode of the product
h. # GO:GSM only
i. # UO:UMTS only
j. # GU:GSM and UMTS
k. # Please select one mode to install.
Please input a valid run_mode :
l. The system prompts you to type the office name. Type the office name and press Enter.
m. # The name of office
n. # The name suggest range from 5 to 32 characters.
o. # The characters suggest be letters, digits, "-"or "_".
Please input a valid office_name :
p. The system prompts you to type the language version. Type the language version and
press Enter.
q. # The OMU language version. eg: eng/chs
Please input a valid version :
r. The system prompts you to type the admin password. Type the admin password,
confirm it, and press Enter.
s. # The "admin" user's password of OMU service.
t. # The password must range from 8 to 32(characters).The
characters must be uppercase letters, lowercase letters, digits,
or special characters.
u. Special characters include spaces and the following
characters:~!@#$^*()_+-{}|[]:./
v. The password must consist of 2 types of uppercase
letter,lowercase letter,digit or special character at least.
w. # Do not forget the password.
x. # You can change the password later, but this password should be
provided first.
y. Please input a valid admin_password :
z. Please input a valid Confirm password :
aa. The system prompts you to type the FTP password. Type the FTP password, confirm it,
and press Enter.
bb. # The ftp user's password of OMU service
cc. # The password must range from 8 to 32(characters).The
characters must be uppercase letters, lowercase letters, digits,
or special characters.
dd. Special characters include spaces and the following
characters:~!@#$^*()_+-{}|[]:./
ee. The password must consist of 2 types of uppercase
letter,lowercase letter,digit or special character at least.
ff. # Do not forget the password.
gg. # You can change it later, but this password should be
provided first.
hh. Please input a valid ftp_password :
ii. Please input a valid Confirm password :
jj. Type the external virtual IP address or a valid external virtual configuration based on the
displayed message.
Example for entering the external virtual IP address:
# The extranet virtual IP.
Please input a valid virtual_extranet_ip :
Example for entering the external virtual configuration:
# The extranet IP address, subnet mask, and default gateway.
# example: 192.168.1.9/255.255.255.0;192.168.1.1
Please input a valid virtual_extranet_config :

NOTE:
External network virtual IP uses the saved former information of standby OMUa board.
After the product software are installed, you can change the IP addresses and subnet
masks of the OMU Ethernet adapters with omutool.
kk. Type Dual, and press Enter.
ll. The system asks you whether to continue with the installation, as shown:
Please affirm input information. input Y to continue; input E to
exit. ->
mm. Type Y to install product software. When the message Install OMU
succeed! is displayed, product software are successfully installed.
10. Change IP addresses of OMU Ethernet adapters and their subnet masks
Perform either of the following operation to change IP addresses of the new OMU:
 Run the MOD OMUIP command. This operation can be performed only if the local
commissioning network adapter is connected to the OMU. For details about this
operation, see the description of the MOD OMUIP command in the MML command
reference.
 Use the omutool to change IP addresses of the OMU. For details, see the following steps.
b. Type the command cd /mbsc/bam/version_a/bin/bam and press Enter to navigate to
the directory containing omutool.
c. Change the OMU IP addresses by referring to the IP addresses of the replaced OMU
board.
 Execute ./omutool innercard IP address to change the internal fixed IP address.
 Execute ./omutool innervip IP address to change the internal virtual IP address.
 Execute ./omutool extercard IP address mask (gateway) to change the external
fixed IP address and subnet mask.
 Use the command ./omutool backupcard_for_omuc IP address to change the
backup channel IP address of the active and standby OMUs of the B_UPDATE0
Ethernet adapter on an OMUc board.
 Use the command ./omutool backupcard_for_omua IP address to change the
backup channel IP address of the active and standby OMUs of the B_UPDATE1
Ethernet adapter on an OMUc board.
 Record the information about the product software installation in Information
Records of OMU Software Installation.

NOTE:
It is recommended that the backup channel IP addresses of the active and standby
OMUs on the Ethernet adapter B_UPDATE0 of the OMUc board be set to 192.168.9.60.
In addition, set the backup channel IP addresses of the active and standby OMUs on the
Ethernet adapter B_UPDATE1 to the backup channel IP address of the OMUa board
that has been removed in Records of the OMU Application Installation Information.
11. Record the information about the product software installation in Information Records of OMU
Software Installation.
12. Only when BSC6900 is configured with the GBFD-511701 Radio Measurement Data
Interface for Navigation feature and the BSC local IP address is used for communication
between the OMU and VNP, you need to reconfigure the BSC local IP address, VLAN IDs for
communication between the OMU and VNP, and VLAN IDs for communication between the
OMU and EMS/LMT based on "OMU Ethernet Adapter Team IP Address Installation
Information." For details, see Radio Measurement Data Interface for Navigation in GBSS
Feature Documentation.
13. Start the omud on the standby OMU board. Run the /etc/rc.d/omud start command and press
Enter to start the omud.
14. Wait 10 minutes while the data of OMUa or OMUb board and the OMUc board is being
synchronized.
After the OMU OS, product software and patches are installed, the data of the OMUa or OMUb
board and the OMUc board is synchronized automatically.
15. Run the DSP OMU command to check the data synchronization progress. When Data-sync
state is Data synchronization is successful, run the SWP OMU command to switch the
OMUc to work as the active OMU.
16. After the active/standby OMU switchover is complete, run the DSP OMU command to check
the data synchronization progress. When Data-sync state is Data synchronization is
successful, stop the OMUd process on the OMUa board, shut down the OMU OS, referring to
2.
17. Repeat 3 to 4 to remove the OMUa board, and install OMUc board.

NOTE:
The OMUc boards can be configured in slots 0 and 1, 2 and 3, 20 and 21, 22 and 23, 24 and
25, or 26 and 27. For example, if one OMUc board is configured in slot 21, the other OMUc
board must be configured in slot 20.
18. Repeat operations in 5 to 9 to install product software.
19. Change IP addresses of OMU Ethernet adapters and their subnet masks by referring to
operations in 10.

NOTE:
It is recommended that the backup channel IP addresses of the active and standby OMUs on
the Ethernet adapter B_UPDATE0 of the OMUc board be set to 192.168.9.50. In addition, set
the backup channel IP addresses of the active and standby OMUs on the Ethernet adapter
B_UPDATE1 to the backup channel IP address of the OMUa board that has been removed in
Records of the OMU Application Installation Information.
20. Only when BSC6900 is configured with the GBFD-511701 Radio Measurement Data
Interface for Navigation feature and the BSC local IP address is used for communication
between the OMU and VNP, you need to reconfigure the BSC local IP address, VLAN IDs for
communication between the OMU and VNP, and VLAN IDs for communication between the
OMU and EMS/LMT based on "OMU Ethernet Adapter Team IP Address Installation
Information." For details, see Radio Measurement Data Interface for Navigation in GBSS
Feature Documentation.
21. Start the omud on the standby OMU board. Run the /etc/rc.d/omud start command and press
Enter to start the omud.
22. Wait 10 minutes while the data of two OMUc boards is being synchronized.
23. Run the RMV BRD command to delete the OMUa or OMUb boards which have been removed
in 17.
24. Run the ADD BRD command to add the OMUc board which has been installed in 17.
25. Run the DSP OMU command to check the data synchronization progress. When Data-sync
state is Data synchronization is successful, go to Common Operation for Replacing OMU
Board.

You might also like