You are on page 1of 71

Tellabs ® 8600 Managed Edge System

Tellabs ® 8607 Access Switch FP1.1


Reference Manual

76.8611-40067A
12.07.2010
Document Information

© 2010 Tellabs. All rights reserved.

This Tellabs manual is owned by Tellabs or its licensors and protected by U.S. and international copyright laws, conventions and
treaties. Your right to use this manual is subject to limitations and restrictions imposed by applicable licenses and copyright laws.
Unauthorized reproduction, modification, distribution, display or other use of this manual may result in criminal and civil penalties.
The following trademarks and service marks are owned by Tellabs Operations, Inc. or its affiliates in the United States and/or
other countries: TELLABS ®, TELLABS ® logo, TELLABS and T symbol ®, and T symbol ®.

Any other company or product names may be trademarks of their respective companies.

The specifications and information regarding the products in this manual are subject to change without notice. All statements,
information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind,
express or implied. Users must take full responsibility for their application of any products.

Adobe ® Reader ® are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

2
Document Information

Terms and Abbreviations

Term Explanation
ATM Asynchronous Transfer Mode
BGP-4 Border Gateway Protocol version 4
BFD Bidirectional Forwarding Detection
BMP Broadband Management Protocol. A communication protocol which is used between
Tellabs 8600 network elements and Tellabs 8000 network manager.
BSC Base Station Controller
CESoPSN Circuit Emulation Service over Packet Switched Network
CLI Command Line Interface
CPU Central Processor Unit
CSMA/CD Carrier Sense Multiple Access/Collision Detect
DELT Dual Ended Loop Test
DSL Digital Subscriber Line
EEC Ethernet Equipment Clock
EEPROM Electrically Erasable Programmable Read Only Memory
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
ERM Electromagnetic Compatibility and Radiospectrum Matters
Fan One fan in a fan module
Fan Module A module consisting of two or more fans, the mechanics and possibly the control
electronics
FIFO First In First Out memory
FLASH Electrically erasable and programmable memory type
FTP File Transfer Protocol
FTP Foil Shielded Twisted Pair
GDT Gas Discharge Tubes
GND Ground
GUI Graphical User Interface
HDLC High-Level Data Link Control
HSDPA High Speed Downlink Packet Access
IMA Inverse Multiplexing for ATM
IP Internet Protocol
IS-IS Intermediate System to Intermediate System (Interior Gateway Protocol)
ITU-T International Telecommunication Union - Telecom Standardization Sector

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

3
Document Information

LAN Local Area Network


LDP Label Distribution Protocol
LED Light-Emitting Diode
LER Label Edge Router
LM Line Module
LSP Label Switched Path
LSR Label Switch Router
MDU Multi-Dwelling Unit
MP-BGP Multiprotocol Border Gateway Protocol
MPLS Multiprotocol Label Switching
MTU Maximum Transfer/Transmission Unit
NE Network Element
NPU Network Processor Unit
OAM Operations, Administration and Maintenance
OCXO Oven Controlled Crystal Oscillator
OSPF Open Shortest Path First
PDH Plesiochronous Digital Hierarchy
PFC Power Factor Correction
PHY Physical Layer Device
PLL Phase Locked Loop
PPC Power PC (processor)
PPP Point-to-Point Protocol
PWE3 Pseudowire Edge to Edge Emulation
PWM Pulse Width Modulation
RAN Radio Access Network
RFC Request For Comments
RNC Radio Network Controller
RSVP-TE Resource Reservation Protocol – Traffic Engineering
RTC Real Time Clock
SAToP Structure-Agnostic Time Division Multiplexing over Packet
SCI Station Clock Input
SCO Station Clock Output
SEC Synchronous Equipment Clock
SFP Small Form-Factor Pluggable
SHDSL Single-Pair High-Speed DSL
SNMP Simple Network Management Protocol
STM Synchronous Transfer Mode

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

4
Document Information

STU SHDSL Transceiver Unit


STU-C STU at the Central Office
STU-R STU at the Remote End
TDM Time Division Multiplexing
UBR Unspecified Bit Rate
VBR Variable Constant Bit Rate
VLAN Virtual LAN (Local Area Network)
VPN Virtual Private Network
xDSL A collective term referring to any of the various types of DSL technologies

Compliance Statement

Hereby, Tellabs Oy declares that this product is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.

FCC Notification Statement

Federal Communications Commission (FCC) Rules require that you be notified of the following:

This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.

Changes or modifications not expressly approved by Tellabs Operations, Inc., in writing can void
the user’s authority to operate the equipment.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

5
Tellabs ® 8600 Managed Edge System 76.8611-40067A
Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

6
Table of Contents

Table of Contents

About This Manual ............................................................................................................ 10

Objectives....................................................................................................................................................................... 10
Audience......................................................................................................................................................................... 10
Related Documentation .................................................................................................................................................. 11
Document Conventions .................................................................................................................................................. 11
Documentation Feedback............................................................................................................................................... 12

Safety Notes ...................................................................................................................... 13

Intended Purpose ............................................................................................................................................................ 13


Class 1 Laser Product..................................................................................................................................................... 13
Jewelry Removal ............................................................................................................................................................ 15
Installation and Maintenance ......................................................................................................................................... 15
Lightning Activity .......................................................................................................................................................... 16

1 System Overview......................................................................................................... 17

1.1 General................................................................................................................................................................. 17
1.2 Tellabs 8600 in Managed RAN Transport Application ....................................................................................... 17
1.3 Tellabs 8600 in Managed Wireline Application .................................................................................................. 19
1.4 Management ........................................................................................................................................................ 20

2 Network Element Overview ........................................................................................ 21

2.1 Enclosure ............................................................................................................................................................. 21


2.1.1 Baseboard ............................................................................................................................................ 21
2.1.2 Fixed Interfaces ................................................................................................................................... 22
2.1.3 Line Module Slots ............................................................................................................................... 22
2.1.4 Cooling ................................................................................................................................................ 22
2.2 NE Powering........................................................................................................................................................ 24
2.3 NE Synchronization............................................................................................................................................. 25
2.4 Technical Specifications ...................................................................................................................................... 26

3 Baseboard.................................................................................................................... 30

3.1 Overview ............................................................................................................................................................. 30


3.2 Main Features ...................................................................................................................................................... 30

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

7
Table of Contents

3.3 Operation ............................................................................................................................................................. 30


3.3.1 CPU Block........................................................................................................................................... 31
3.3.2 NPU Block........................................................................................................................................... 32
3.3.3 IFMUX Block...................................................................................................................................... 32
3.3.4 Timing Block ....................................................................................................................................... 32
3.3.5 Asynchronous Serial Interface and External Alarm Interface............................................................. 32
3.3.6 Power Supply....................................................................................................................................... 32
3.3.7 Test Features ........................................................................................................................................ 32
3.4 Interfaces ............................................................................................................................................................. 33
3.4.1 Line Modules....................................................................................................................................... 33
3.4.2 Fixed Interfaces ................................................................................................................................... 35
3.4.3 SFP Transceivers ................................................................................................................................. 37
3.5 Front Panel and Connectors................................................................................................................................. 44
3.5.1 Optical Ethernet Interface.................................................................................................................... 44
3.5.2 Electrical Ethernet Interface ................................................................................................................ 44
3.5.3 Station Clock Input and Output Interface............................................................................................ 45
3.5.4 CLI Interface........................................................................................................................................ 45
3.5.5 External Alarm Interface ..................................................................................................................... 46
3.6 LEDs.................................................................................................................................................................... 47
3.6.1 NE Status LEDs................................................................................................................................... 47
3.6.2 Ethernet LEDs ..................................................................................................................................... 47
3.7 Technical Specifications ...................................................................................................................................... 48
3.7.1 Baseboard Technical Specifications .................................................................................................... 48
3.7.2 Interfaces Technical Specifications ..................................................................................................... 48

4 Power Modules ............................................................................................................ 50

4.1 DC Power Module ............................................................................................................................................... 50


4.1.1 Overview ............................................................................................................................................. 50
4.1.2 Interfaces ............................................................................................................................................. 50
4.1.3 Operation ............................................................................................................................................. 51
4.1.4 Front Panel and Connectors................................................................................................................. 51
4.1.5 Input Fault Detection and LED ........................................................................................................... 51
4.1.6 Technical Specifications ...................................................................................................................... 51

5 Line Modules ............................................................................................................... 52

5.1 2-Port ADSL Line Module (2xADSL)................................................................................................................ 52


5.1.1 Overview ............................................................................................................................................. 52
5.1.2 Front Panel and Connectors................................................................................................................. 53
5.1.3 LEDs.................................................................................................................................................... 54
5.1.4 Cabling ................................................................................................................................................ 55
5.1.5 Technical Specifications ...................................................................................................................... 55
5.2 4-Port SHDSL Line Module (4xSHDSL) ........................................................................................................... 56
5.2.1 Overview ............................................................................................................................................. 56
5.2.2 Front Panel and Connectors................................................................................................................. 57
5.2.3 LEDs.................................................................................................................................................... 57
5.2.4 Cabling ................................................................................................................................................ 58
5.2.5 Technical Specifications ...................................................................................................................... 58
5.3 8-Port Fast Ethernet Line Module (8x10/100BASE-TX).................................................................................... 59

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

8
Table of Contents

5.3.1 Overview ............................................................................................................................................. 59


5.3.2 Front Panel and Connectors ................................................................................................................ 60
5.3.3 LEDs.................................................................................................................................................... 60
5.3.4 Cabling ................................................................................................................................................ 61
5.3.5 Technical Specifications ...................................................................................................................... 61
5.4 8-Port Channelized E1 / Channelized T1 Line Module (8xchE1/chT1) ............................................................ 62
5.4.1 Overview ............................................................................................................................................. 62
5.4.2 Front Panel and Connectors................................................................................................................. 63
5.4.3 LEDs.................................................................................................................................................... 64
5.4.4 Cabling ................................................................................................................................................ 64
5.4.5 Technical Specifications ...................................................................................................................... 65

References......................................................................................................................... 66

End of Life Treatment ....................................................................................................... 71

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

9
About This Manual

About This Manual


This section discusses the objectives and intended audience of this manual, Tellabs ® 8600 Managed
Edge System Tellabs ® 8607 Access Switch Reference Manual and consists of the following
sections:

• Objectives
• Audience
• Related Documentation
• Document Conventions
• Documentation Feedback

Objectives

The goal of this manual is to describe the network element features of Tellabs 8607 access switch.

Audience

This manual is intended for system specialists and personnel involved in network planning.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

10
About This Manual

Related Documentation

The new document numbering scheme consists of the document ID, indicated by numbers, and the
document revision, indicated by a letter. The references in the Related Documentation table below
are generic and include only the document ID. To make sure the references point to the latest
available document versions, please refer to the relevant product document program on the Tellabs
Portal by navigating to www.portal.tellabs.com > Product Documentation > Data Networking >
Tellabs 8600 Managed Edge System > Technical Documentation.

For more information on the Tellabs 8600 system and network elements, see the following
documentation:

Tellabs ® 8600 Managed Edge System Provides guidance on mechanical installation,


Hardware Installation Guide (76.8600-40039) grounding, powering, cabling and maintenance.
Tellabs ® 8600 Managed Edge System Provides commands available to configure, monitor
CLI Commands Manual (76.8600-50117) and maintain Tellabs 8600 managed edge system
products with CLI.
Tellabs ® 8600 Managed Edge System Provides an overview of Tellabs 8600 managed edge
Configuration Guides system functions and instructions on how to configure
them with CLI.
Tellabs ® 8000 Intelligent Network Manager Provides instructions on how different operations are
Online Help performed with Tellabs 8000 intelligent manager.
Describes also different parameters and controls of
the Tellabs 8000 intelligent manager dialogs and
windows.

Document Conventions

This is a note symbol. It emphasizes or supplements information in the document.

This is a caution symbol. It indicates that damage to equipment is possible if the instructions
are not followed.

This is a warning symbol. It indicates that bodily injury is possible if the instructions are not
followed.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

11
About This Manual

Documentation Feedback

Please contact us to suggest improvements or to report errors in our documentation:

Email: fi-documentation@tellabs.com

Fax: +358.9.4131.2430

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

12
Safety Notes

Safety Notes
This chapter lists safety notes and their translations for Tellabs 8600 network elements.

Intended Purpose

The equipment shall be used only for its intended purpose.

Das Gerät soll nur für den vorgesehen Einsatzzweck verwendet werden.

CAUTION: Do not insert an RJ-11 (telephone) plug into Ethernet or E1/T1 ports. Equipment
damage may result.
ACHTUNG: Stecken Sie keine RJ-11 (Telefon) Stecker in die Ethernet oder E1/T1 Anschlüsse
da dieses zu einer Beschädigung des Gerätes führen kann.

CAUTION: Do not climb on or stand on the Tellabs 8600 network element. Neither the network
element nor its enclosure is designed to support the weight of a person.
ACHTUNG: Steigen Sie oder stellen Sie sich nicht auf das 8600 Netzwerk Element. Weder
des Netzwerk Element noch das Gehäuse sind dafür ausgelegt worden das Gewicht einer
Person zu tragen.

Class 1 Laser Product

Class 1 laser product.


Laserprodukt der Klasse 1.

WARNING: No other types of lasers can be used than supplied and approved by Tellabs. If
other types are used, the laser class and compliance to laser safety and EMC standards
must be checked.
WARNUNG: Verwenden Sie keine anderen als die von Tellabs gelieferten und zugelassenen
Lasertypen. Falls Sie andere Typen verwenden, müssen die Laserklasse und die Einhaltung
von Lasersicherheits- und EMV-Normen geprüft werden.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

13
Safety Notes

WARNING: Install only lasers that have been demonstrated to meet Class 1 eye safe levels by
a Nationally recognized Authority such as The Food and Drug administration’s 21CFR1040
Laser Energy Source, UL 60950-1 Information Technology equipment and European norms
EN60950-1, EN60825-1 and EN60825-2. Failure to use laser transceivers which meet these
standards could result in eye damage to users or service personnel working around the
equipment.
WARNUNG: Installieren Sie nur Laser der Klasse 1 die die Augenschutz Richtlinien
der staatlich anerkannten Organisationen wie z.B. The Food and Drug administration’s
21CFR1040 Laser Energy Source, UL 60950-1 Information Technology equipment oder die
Europa Normen EN60950-1, EN60825-1 und EN60825-2 erfüllen. Laser die diese Standards
nicht erfüllen können zu Verletzungen an Augen des Benutzers und des Service Personals
das in der Nähe der Geräte arbeitet führen.

WARNING: Optic operation should be verified by observing the status LEDs. Do not look into
the laser or fiber to verify operation.
WARNUNG: Überprüfen Sie die Funktionstüchtigkeit der Optischen Einheit anhand der Status
LED. Schauen Sie nie in den Laser oder die Glasfaser um die Funktion zu prüfen.

WARNING: Because invisible radiation may be emitted from the aperture of the port when no
fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
WARNUNG: Aus der Stecker Öffnung können unsichtbare Strahlen emittieren wenn kein
Glasfaserkabel angeschlossen ist. Vermeiden Sie es sich den Strahlungen auszusetzen und
starren Sie nicht in die Öffnungen.

WARNING: If you are going to remove the power module from Tellabs 8607 access switch
or the power input module from Tellabs 8620 access switch or CDC from Tellabs 8660 edge
switch/Tellabs 8630 access switch, first turn off the power switch (if any), then detach the
power cable and only after these actions, remove the power module or CDC. Never keep the
power cable connected to the power module or CDC while it is out of its slot. Otherwise the
power module or CDC may cause bodily injury or damage to the part that it is touching.
WARNUNG: Vor dem Entfernen des Netzteilmoduls des Tellabs 8607 access switch oder
des Netzeingangsmoduls des Tellabs 8620 access switch oder der CDC-Karte des Tellabs
8660 edge switch/Tellabs 8630 access switch zuerst den Netzschalter (falls vorhanden)
ausschalten und danach das Netzkabel vom Netzteil trennen. Erst jetzt das Netzteilmodul
oder die CDC-Karte ausbauen. Lassen Sie niemals das Netzkabel mit dem Netzteilmodul oder
CDC verbunden, während es aus seinem Einschub ausgebaut ist. Andernfalls kann es zu
Verletzungen kommen oder andere Bauteile durch Berührung beschädigt werden.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

14
Safety Notes

Jewelry Removal

WARNING: Before working on equipment that is connected to power source, remove jewelry
(including rings, necklaces, and watches). Metal objects will heat up when connected to
power and ground and can cause serious burns or weld the metal object to the terminals.
WARNUNG: Bevor Sie an Geräten arbeiten die an eine Spannungsversorgung angeschlossen
sind, entfernen Sie all Ihren Schmuck (einschließlich Ringe, Ketten und Uhren). Metallobjekte
erhitzen sich wenn sie einen Kurzschluss zwischen Spannungsversorgung und Masse/Erdung
verursachen. Dieses kann zu schweren Verbrennungen führen oder das Anschweißen an die
Anschlussklemmen zur Folge haben.

Installation and Maintenance

WARNING: This equipment is to be installed and maintained by qualified service personnel


only.
WARNUNG: Dieses Gerät darf nur von qualifiziertem Fach- oder Servicepersonal installiert
oder gewartet werden.

CAUTION: Electrical interfaces may require external protection devices to safeguard against
overvoltages, transients, earth potential differences and/or power cross-contacts.
ACHTUNG: Elektrische Anschlüsse benötigen evtl. externe Schutzschaltungen
um sie vor Überspannung, Einschaltspitzen, Erdpotentialunterschieden und/oder
Fremdspannungsüberlagerung zu schützen.

CAUTION: While handling the modules (Interface Modules, Line Modules, CDC, Line Cards,
Power Modules and Fan Modules) of the Tellabs 8600 network elements, always take care of
proper handling, e.g. do not bend or twist the modules, do not touch the components on the
modules, take care of good ESD working practices, do not use excessive force while inserting
or removing the modules, do not drop the modules.
ACHTUNG: Beim Umgang mit den Modulen (Schnittstellenmodulen, Netzmodulen, CDC,
Netzkarten, Netzteilmodulen und Lüftermodulen) der Tellabs 8600-Netzwerkelemente sorgsam
umgehen, d. h. die Module nicht verbiegen oder verdrehen, die Bauteile auf den Modulen
nicht berühren, auf gute Arbeitspraktiken im Zusammenhang mit elektrostatischer Entladung
achten, beim Ein- oder Ausbauen der Module keine übermäßige Kraft anwenden und die
Module nicht fallen lassen.

WARNING: For US usage: this equipment must only be used with a Nationally Recognized
Testing Laboratory (NRTL) approved power supply.
WARNUNG: Für den Gebrauch in den USA: Dieses Gerät darf nur mit einer von einer national
anerkannten Test Einrichtung (NTRL) zugelassenen Spannungsversorgung betrieben werden.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

15
Safety Notes

WARNING: Read the installation instructions before you connect the system to its power
source.
WARNUNG: Lesen Sie die Installationsanweisungen bevor Sie das System an die
Spannungsversorgung anschließen.

WARNING: When installing or performing maintenance on the equipment, the ground


connection must always be made first. Never operate or maintain an ungrounded equipment.
WARNUNG: Bei der Installation oder bei Wartungsarbeiten am Gerät muss die Masse/Erdung
immer als erstes angeschlossen werden. Betreiben Sie oder arbeiten Sie niemals an einem
Gerät das nicht geerdet ist.

WARNING: The fan propeller will continue rotating momentarily after extraction. Be careful
not to touch the propeller before rotation has stopped.
WARNUNG: Das Lüfterrad kann sich nach dem Entnehmen der Einheit noch drehen. Achten
Sie darauf das Lüfterrad nicht zu berühren bevor es komplett zum Stillstand gekommen ist.

Lightning Activity

WARNING: Do not work on the system or connect or disconnect cables during periods of
lightning activity.
WARNUNG: Arbeiten Sie während eines Gewitters mit Blitzschlag nicht an dem Gerät oder
schließen Sie auch keine Kabel an bzw. trennen Sie keine ab.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

16
1 System Overview

1 System Overview

1.1 General

The Tellabs 8600 managed edge system is a managed MPLS access solution aimed at deployment
of mobile transport networks, and Ethernet and IP VPN services as well as broadband service
aggregation for Internet services. The system is especially designed for the service provider
environment with carrier class functionality, simultaneously supporting both connection-oriented
(MPLS) and connectionless (IP) operations. The use of IP/MPLS technology with enhanced quality
of service features enables differentiated services in which the service quality can be predefined for
all traffic types and the availability of service can be protected with options built into the system. The
quality of service is guaranteed with DiffServ and DiffServ-aware MPLS traffic engineering already
in the access part of the network. The service speeds are flexible ranging from 1 kbps to 1 Gbps.
The connectivity services such as intranet, extranet, Internet access and voice communications are
implemented as Ethernet PWE3 (or other PWE3 types), or IP VPN according to [RFC4364].

The boundary between mobile and wireline services and networks is disappearing. From the cost
point of view it makes sense to use the same network for all services. The Tellabs 8600 platform has
a native support for services such as any-to-any IP VPN, Ethernet and ATM, all of which can be
end-to-end provisioned and managed. Additionally the same platform can take care of the Internet
traffic aggregation, which is one of the most rapidly growing businesses in terms of bandwidth.

1.2 Tellabs 8600 in Managed RAN Transport Application

For the mobile radio access networks (RAN) the Tellabs 8600 managed edge system offers a future
proof solution that caters the whole network technology evolution from TDM to ATM and eventually
to an ‘all IP’ RAN phase. As shown in the figure below the platform is positioned to cover the
whole transport network all the way from the cell sites to the edge of the mobile core. Throughout
all the evolution phases traffic grooming, service quality and transport can be managed and
optimized end-to-end across the same Tellabs 8600 network. Even though 3G is the primary driver
to implement the Tellabs 8600 system, the same platform – thanks to flexible MPLS technology
and Tellabs 8600 intelligent design – can be responsible for access aggregation for 2G and 2.5G
networks and services. The Tellabs 8600 platform offers an opportunity for a mobile operator to
broaden the service portfolio and increase revenue by offering advanced business or residential
services, such as managed WiFi access, IP VPNs, business critical Ethernet or Internet access.
Introducing services is extremely fast and cost-effective as all the service intelligence is in-built to
the system. The Tellabs 8600 system can be regarded as a real long term investment as it allows the
network convergence in the access, where the network investments are the most remarkable.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

17
1 System Overview

Fig. 1 Tellabs 8600 Position in RAN

The Tellabs 8600 system is able to cover the whole RAN network from the cell site to the mobile
core. The figure above illustrates the typical roles and locations of the elements in the network,
which are

• RNC/BSC sites (Tellabs 8660 edge switch)


• Access aggregation, i.e. hub sites (Tellabs 8620 access switch, Tellabs 8630 access switch and
Tellabs 8660 edge switch)
• Cell or base station sites (Tellabs 8605 access switch, Tellabs 8607 access switch and Tellabs
8620 access switch)
• MPLS-enabled multitechnology and service support
The Tellabs 8600 system can simultaneously take care of mobile traffic aggregation of 2G, 2.5G,
3G, LTE, and WiMAX traffic even though they are based on various protocols. The flexible
equipping and multiservice interfaces of the Tellabs 8600 system enable building the network in the
most economical way. The Tellabs 8600 system can optimize the bandwidth use in the network
even by cross-connecting ATM VP/VC connections. All the incoming traffic can be mapped to the
needed traffic classes before it enters the MPLS network. Overbooking, which is essential for
lower priority and bursty data services, can be used across the network. Finally, utilizing MPLS
PWE3 tunnelling the ATM, TDM, and Ethernet traffic can be carried through the Tellabs 8600
network. Synchronization can be arranged to cell sites using various methods from SONET/SDH
to packet synchronization.

Tellabs 8605 access switch and Tellabs 8607 access switch are compact pseudowire gateways
optimized for cell sites. They enable a cost-effective transport solutions where mobile data traffic
(e.g. HSDPA) is carried over xDSL as an option to E1/T1 lines. Tellabs 8607 access switch
provides modularity with various types of line modules, while Tellabs 8605 access switch has a
fixed interface configuration.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

18
1 System Overview

1.3 Tellabs 8600 in Managed Wireline Application

The Tellabs 8600 managed edge system is composed of customer located devices, access network
devices and a network management system. All network elements are implemented with the same
architecture where traffic forwarding is fully hardware-based. Tellabs 8660 edge switch and Tellabs
8630 access switch are modular access aggregation and edge switch routers usually residing either
in the local exchange or transit exchange site of the network. The scalable, switchless architecture
allows various locations in the network. It is able to take care of tailored traffic treatment and
network reliability. When Tellabs 8660 edge switch or Tellabs 8630 access switch is used together
with Tellabs 8605 access switch/Tellabs 8607 access switch/Tellabs 8620 access switch, it provides
end-to-end managed services with guaranteed service availability, quality and security. Tellabs
8605 access switch, Tellabs 8607 access switch, and Tellabs 8620 access switch are optimized for
small local exchange sites.

Tellabs 8606 Ethernet aggregator enables a scalable solution for Ethernet access based services.
These network elements can be applied e.g. as access switches in MTU/MDU buildings or as
traffic aggregators in Ethernet access networks grooming VLAN based attachment circuits to
Tellabs 8660 edge switch.

The design of the Tellabs 8600 system is fully interoperable with other leading IP/MPLS products
allowing multi-vendor environment.

Fig. 2 Tellabs 8600 Position in Service Provider Network

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

19
1 System Overview

1.4 Management

The Tellabs 8600 managed edge system can be managed by using Tellabs 8000 network manager
which is a network management system that provides the tools for network building, monitoring,
service creation, testing and control. Network complexity is simplified by a graphical user interface
which provides access to the functionalities from the same workstation. The command-line interface
(CLI) provides access to equal functionality to configure and monitor the Tellabs 8600 products
with ASCII textual commands using a router’s console or remote terminal (Telnet). The CLI gives
full control to all of the router’s functionality.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

20
2 Network Element Overview

2 Network Element Overview

2.1 Enclosure

The Tellabs 8607 access switch enclosure can be installed into a 19” rack. Installation into a 23”
and ETSI 600 mm rack is supported with additional rack side adapters. The outer dimensions of
the enclosure are 446 x 44.35 (=1U) x 250 mm (w x h x d). The air inlet and outlet holes are on
the left and right hand side of the enclosure. The side adapters are removable. All the connectors
including the one for power are on the front side of the enclosure.

Fig. 3 Tellabs 8607 Access Switch Enclosure

Fig. 4 Tellabs 8607 Access Switch Front Panel

2.1.1 Baseboard

Tellabs 8607 access switch is a stand alone NE and uses a baseboard architecture. This means that
the functionality including NE fixed interfaces have been integrated into a single main baseboard.
All fixed interfaces are accessible from the NE front panel.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

21
2 Network Element Overview

2.1.2 Fixed Interfaces

Tellabs 8607 access switch provides the following types of fixed interfaces.

• 100/1000BASE-X, or 10/100BASE-TX/1000BASE-T
• Station Clock Input (SCI)
• Station Clock Output (SCO)
• External alarm interface

2.1.3 Line Module Slots

There are three slots, M0, M1 and M2, for the line modules (LMs). The user can choose the media
type according to needs.

The LMs are not of hot-insertion type.

2.1.4 Cooling

Tellabs 8607 access switch is forced convection-cooled equipment. Fresh air is taken from the left
side of the enclosure and blown through the baseboard and the line modules. The outlet air leaves
the enclosure on the right hand side. Forced cooling is needed to dissipate the generated heat load
and to maintain the components within their operating limits. In case of a failure in one fan the
others will maintain adequate cooling for a limited time.

The baseboard is able to monitor the equipment temperature. The temperature warning is raised
when the measured temperature exceeds +81° C. The warning indicates that the operating ambient
temperature is high and about to exceed the allowed operating range. This will occur at ambient
near +65° C. The equipment will go to reset mode after 15 minutes if the measured temperature is
+90° C or higher or immediately if it is +100° C or higher. This is to protect the equipment from
permanent damage caused by high temperature.

The rotation speed control of the fans is based on the temperature values measured from the
baseboard. The fan speed is adjusted smoothly between 0% and 100% of the maximum rotation
speed. The fans will increase the rotation speed to maintain the required operating temperature.
At cold ambient temperatures the fans are shut down. The warning of high temperature will occur
when the equipment is used at high ambient temperature. If the warning occurs and the equipment is
not used at high ambient temperatures, it might be advisable to change the air filter. At start up the
fans are running at maximum speed until the equipment boot up is completed.

The air filter is located in the inlet side of the fan module. It prevents dust from entering the
enclosure and keeps the inside cleaner in order to maintain adequate cooling. An empty line or
power module slot must be shielded with a cover plate.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

22
2 Network Element Overview

Fig. 5 Tellabs 8607 Access Switch Air Filter

The fan module and air filter can be replaced or removed on the fly without disturbing the data
traffic through the network element. Please refer to Tellabs ® 8600 Managed Edge System Hardware
Installation Guide for more details.

Fan Module

The fan module is located on the left hand side of the NE and contains four parallel fans. The
baseboard is able to control and monitor the operation of the fans. The rotation speed is adjusted
according to the temperature inside the enclosure, and in case of failure in one fan the other three
will maintain adequate cooling for a limited time.

Fig. 6 Tellabs 8607 Access Switch Fan Module

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

23
2 Network Element Overview

The operating ambient temperature range for Tellabs 8607 access switch is -40°C — +65°C.
However the start up of the NE is allowed at ambient temperature -20°C or above.

The fan driving circuits are located on the fan backplane module. The baseboard controls the fan
rotating speed via the I2C-bus and monitors the alarms.

Technical Specifications

Dimensions 23 x 40 x 234 mm (w x h x d)
Weight 121 g
Power consumption Typical 4.5 W
Max. 7 W
Time to change fan single fan failure Within three days
module
more than one fan failure Within three hours, or at least within
one day
Air filter change At least twice a year
Start up ambient temperature -20°C or above

2.2 NE Powering

Tellabs 8607 access switch can be powered with either -48 Vdc or +24 Vdc battery voltages. The
NE provides two slots for DC power modules. If redundant power feeding is required, it is achieved
by installing a DC power module in both slots. An empty power module slot must be shielded with
a cover plate. The DC power modules are hot-swappable.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

24
2 Network Element Overview

2.3 NE Synchronization

Tellabs 8607 access switch has an integrated clock generator that is located on the baseboard and
distributes the clock signal to every interface. The clock level is according to [G.8262], [G.813]
option 1 or [GR-1244-CORE] Stratum-3. An Oven Controlled Oscillator (OCXO) is provided to
meet Telcordia requirements [GR-1244-CORE] for Stratum-3 level clock, holdover frequency
stability at variable temperature.

The NE provides one SCI and one SCO. The SCI is intended to connect an external reference clock
to the NE. Within the external synchronization interface it is possible to configure [G.703] 2048 kHz
synchronization clock mode, 1544 kbps (DS1) or 2048 kbps (E1).

The Node Clock PLL allows synchronization to be derived from any clock source interface or
external synchronization interface that is at least a SEC or Stratum-3 level clock. The clock quality
level requirements for Ethernet Equipment Clock (EEC) synchronization function are specified in
[G.8262].

The NE can be synchronized with a clock derived from any of the following input signals:

• SCI
• Framed E1
• 2048 kHz
• Framed T1
• PDH interfaces
• E1
• T1
• Ethernet interfaces
• 100/1000BASE-X
• 10/100BASE-TX/1000BASE-T
• 10/100BASE-TX
• xDSL interfaces
• SHDSL
The selected reference signal must fulfil the clock characteristics mentioned in the specifications.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

25
2 Network Element Overview

2.4 Technical Specifications

Hardware and software capabilities are listed below.

Enclosure physical size 446 x 44.35 x 250 mm (w x h x d).


17.56 x 1.75 x 9.84 in (w x h x d).
Standard 19-inch, 23-inch or ETSI 600 mm rack or cabinet
mounting.
Weight 2.65 kg with adapters, but without fan, power and line modules.
Safety compatibility [EN 60950-1:2001].
[IEC 60950-1:2001].
Electromagnetic compatibility [EN 300 386:2005].
Installation environment: telecommunication center.
Climatic/mechanical compatibility Storage:
[ETSI EN 300 019-1-1] Class 1.1.
Temperature: -5° C to +45° C (+23° F to +113° F).
Transportation:
[ETSI EN 300 019-1-2] Class 2.3.
Temperature: -40° C to +70° C (-40° F to +158° F).1
Operating conditions:
[ETSI EN 300 019-1-3] Class 3.22
Temperature range: -40° C to +65° C (-40° F to +149° F).
Cold start-up ambient temperature -20° C/ -4° F or above.3
Equipped with ADSL module operating temperature: -5° C to
+45° C (+23° F to +113° F).
See also Fig. 7.
Relative humidity: 5% to 95%.
Usage altitude 60 m below sea level (106 kPa air pressure) to
3000 m (70 kPa).

The operational temperature range of the whole network element is determined on the
narrowest operating temperature of the line modules used.

Check that the operational temperature range of the SFP module is suitable for the installation
environment. Note that the temperature of the SFP case can be approximately 15 degrees
higher than the ambient temperature. For more information on the allowed SFP case
temperature range see chapter 3.4.3 SFP Transceivers.

1Rainis not allowed.


2Condensation is not allowed.
3When the equipment is started up, the ambient temperature shall be -20° C/ -4° F or warmer.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

26
2 Network Element Overview

Power input specification with DC DC Power Module


Power Modules • Support for both -48 Vdc and +24 Vdc nominal input
voltages.
• -40.5 ... -60 Vdc and +19 ... +30 Vdc absolute input voltage
ranges.
• 1.6 A (-48 Vdc) maximum current.
• 3.5 A (+24 Vdc) maximum current.
• 2 x 5 A SMD fuses.4
• 1+1 power protection with two DC power modules.
Power consumption Maximum cooling capacity of the NE is 65 W.
The typical and maximum power consumption values for all
modules can be seen in the corresponding chapters of this
manual. By adding up the power consumption figures of
different modules including the fan module and baseboard,
you will get the typical and maximum figures for the whole
NE. Check that the maximum figure is below the maximum
permissible figure for the NE.
Heat dissipation In practise, all electrical power turns into heat in Tellabs 8600
NEs. Thus, when calculating the power dissipation of the NE,
the same figure represents the heat dissipation in watts.
Interfaces 2 x 10/100BASE-TX/1000BASE-T or 1000BASE-X (SFP
transceiver).
Station clock input (SCI): Framed 2048 kbps (G.703), NRZ
2048 kHz, and framed 1544 kbps signal.
Station clock output (SCO): Framed 2048 kbps (G.703), NRZ
2048 kHz, and framed 1544 kbps signal.
External alarm interface.
Management interfaces: RS-232 serial (RJ-45 type) and
Ethernet ports (management via user ports possible).
Line Modules (LM) – 4-port SHDSL Line Module.
– 8-port Fast Ethernet Line Module.
– 8-port channelized E1 / channelized T1 Line Module.
– 2-port ADSL Line Module.
Performance Field-programmable NPU-based forwarding architecture.
Throughput up to 2 Gbps.
2 K label-switched LSPs and 300 terminated LSPs.
128 ingress terminated RSVP-TE tunnels.
128 egress terminated RSVP-TE tunnels.
256 transient RSVP-TE tunnels.
8K IPv4 routes.
512 VLANs.
Up to 128 cross-connected ATM VPs.
Up to 128 cross-connected ATM VCs.
ATM functionality ATM VP and VC level cross-connecting.
ATM IMA versions 1.0 and 1.1.
ATM OAM loopback and fault management.
IPv4 and MPLS routing and label Static routing, OSPF-TE [RFC3630], IS-IS-TE [RFC3784],
distribution protocols (MP)-BGP4 [RFC1771] and [RFC2858],
LDP [RFC3036], RSVP-TE [RFC3209].

4There should be no need for a fuse change. The SMD fuses are on the DC Power Module PCB and only Tellabs Repair Center is allowed to change
these fuses.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

27
2 Network Element Overview

L3 VPN technologies IP VPNs based on [RFC4364].


PWE3 ATM N-to-One Cell Mode PWE3 [RFC4717].
ATM One-to-One Cell Mode PWE3 [RFC4717].
TDM SAToP [RFC4553].
TDM CESoPSN [RFC5086].
HDLC PWE3 [RFC4618].
Ethernet Raw Mode PWE3 [RFC4448].
Ethernet Tagged Mode PWE3 [RFC4448].
VCCV BFD.
VCCV LSP ping.
PWE3 line and equipment loops.
Performance Management (PM) records for TDM PWE3.
Multi-segment pseudowires.
Ethernet Functionality Virtual LAN (VLAN) interfaces.
Ethernet line and equipment loops.
Stacked VLANs (Q-in-Q) in PWE3 applications.
VLAN cross-connections.
TDM functionality Nx64k PPP, HDLC, and CESoPSN attachment circuits.
P12x and DS1 cross-connections.
Nx64k circuit cross-connections.
Framed and unframed E1 and T1 circuits.
GR-253 and G.826 performance monitoring.
xDSL functionality G.SHDSL [G.991.2].
• Extended bit rate support (5696 kbps per pair).
• EFM over copper [IEEE 802.3ah].
• Ethernet-based multi-pair bonding [G998.2].
• ATM transport mode.
• ATM IMA.
• Network timing reference transport.
ADSL [G.992.1], ADSL2 [G.992.3], ADSL2+ [G.992.5].
• ATM-based multi-pair bonding [G.998.1].
Synchronization ITU-T G.813 option 1
ITU-T G.8262
Telcordia GR-1244-CORE Stratum-3 .
Station Clock Input (SCI).
Station Clock Output (SCO).
Synchronous Ethernet.
G.8264 SSM over Ethernet.
Adaptive synchronization from SAToP PWE3 and CESoPSN
PWE3.
IEEE1588v2 frequency synchronization slave.
Oven Controlled Crystal Oscillator - OCXO.
SHDSL symbol clock.
Link layer technologies Ethernet, VLAN, ATM, ATM IMA, PPP, ML-PPP.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

28
2 Network Element Overview

Quality of service functionality DiffServ, DiffServ aware MPLS Traffic Engineering [RFC3270]
and [RFC3564].
E-LSP support.
4 queues per Ethernet port with strict priority scheduling.
7 queues per E1/T1 port with 2 SP + 5 WFQ scheduling.
7 traffic classes (AF classes aggregated to same queue in
Ethernet ports).
Traffic classification can be done based on MPLS EXP, Ethernet
PRI, VLAN ID, port, and IP DSCP/TOS field.
Traffic policing with Two rate Three Color Marking (trTCM).
Traffic shaping per VLAN and Ethernet port.
ATM CBR, rt-VBR, nrt-VBR, UBR+ and UBR service
categories.
Resiliency Redundant DC power module.
1:1 RSVP-TE LSP protection.
Fast Reroute [RFC4090], One-to-One and Facility backup
modes.
Dynamic LSP rerouting.
OSPF Graceful Restart helper mode [RFC3623], Graceful
Restart helper mode mechanism for BGP with MPLS
[draft-ietf-mpls-bgp-mpls-restart] and LDP Graceful Restart
[RFC3478] mechanisms.
Restart signaling for Intermediate System to Intermediate
System (IS-IS) [RFC3847].
Connectivity verification IPv4 ping and traceroute.
LSP ping and traceroute for RSVP-TE tunnels [RFC4379].
BFD over VCCV [draft-ietf-pwe3-vccv].
Single-hop BFD [draft-ietf-bfd-base-03].
ATM OAM loopback [I.610].
IEEE802.1ag Ethernet OAM loopback, link trace and continuity
check.
Packet Loop Tester (PLT) echo.
Management protocols CLI, FTP, SNMP (read), proprietary BMP.
Configuration Change Notifications (CCN).

Fig. 7 Hot Surface Warning

Tellabs 8607 access switch can be used at up to +65° C ambient temperature, in which case the
temperature of the enclosure will be high too. A marking required by safety standard [IEC60950-1]
for surfaces exceeding +70° C is attached to such equipment that may exceed this limit. Tellabs
8607 access switch must be installed in a location which is accessible only to service personnel or
specially trained users (restricted access location as defined in [IEC60950-1]). It must be ensured
that unauthorized persons cannot access the installation.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

29
3 Baseboard

3 Baseboard

3.1 Overview

The baseboard is the basic element of Tellabs 8607 access switch. It provides the main NE
functionality with fixed Ethernet interfaces and three slots for pluggable line modules, thus enabling
flexibility to choose different media types of interfaces according to the operator’s needs. A separate
power module is used to feed the NE.

The Tellabs 8607 access switch baseboard mainly comprises of a diverse processor environment,
switch/routing engine and physical interfaces.

3.2 Main Features

• Power PC based CPU subsystem with DDR RAM


• FLASH memories for application software, field upgrade possible
• NPU based layer 2 and layer 3 packet switching, packet forwarding, packet filtering and traffic
management functions
• Contains DC/DC converters for lower voltages
• 10/100BASE-TX/1000BASE-T, or 100/1000BASE-X Ethernet interfaces
• Station clock input/output and reference clock selector and monitoring
• Asynchronous console port for local management
• External alarm interface
• Operation voltage monitoring and unit temperature measurement
• Real time clock
• Serial EEPROM for the factory parameters
• Three slots for pluggable line modules

3.3 Operation

The function of the baseboard is to concentrate packet based data received from any interface to
NPU and vice versa. The NPU performs layer 2 and layer 3 packet switching, packet forwarding,
packet filtering and traffic management functions. The Power PC based CPU subsystem is used to
control the baseboard functionality.

The following figure presents the functional block diagram.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

30
3 Baseboard

Fig. 8 Tellabs 8607 Access Switch Functional Block Diagram

3.3.1 CPU Block

The CPU subsystem has an integrated processor from the Power PC family with a 32-bit RISC
processor core with useful internal features, such as independent on-chip cache and memory
management unit. The CPU subsystem is located on a mezzanine module top of the baseboard.

The CPU block includes the following types of memories:

• DDR DRAM
• Boot and application FLASH
The application software is stored in the FLASH memory. Thus, it is possible to update the software
on the field, for example, to have a new feature. Similarly, the card and interface parameters are
stored in FLASH, so those are restored after reset.

RTC

The real time clock has backup for short power breaks. The time is kept for at least 20 hours (at
20º Celsius).

A/D Converter

There is an analog to digital converter on the baseboard. It is used to measure and monitor operating
voltages and temperature.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

31
3 Baseboard

3.3.2 NPU Block

The NPU performs layer 2 and layer 3 packet switching, packet forwarding, packet filtering and
traffic management functions. As a buffer the NPU uses DDR type of memory.

Next to the NPU there is FPGA that serves as the LM interface chip which multiplexes and switches
data between the LMs and the NPU.

3.3.3 IFMUX Block

The IFMUX is a field programmable logic device that serves as a multiplexing block to adapt traffic
between the NPU and the LMs. It provides also a part of the Timing Block functionality.

3.3.4 Timing Block

The timing block consist of Node Clock PLL, OCXO and External Synchronization Interface
(SCI/SCO). The specifications for the EEC synchronization function are specified in [G.8262]. It is
possible to configure External Synchronization Interface to [G.703] 2048/1544 kHz synchronization
clock mode, 1544 kbps (DS1) or 2048 kbps (E1).

Node clock PLL allows synchronization to be derived from any line module interface; fixed Ethernet
interface and External Synchronization Interface that is at least a SEC or Stratum-3 level clock.

3.3.5 Asynchronous Serial Interface and External Alarm Interface

The asynchronous serial interface is used for CLI local management connections. The alarm
interface is used for gathering alarm type of information from external devices.

3.3.6 Power Supply

The baseboard has several local, integrated power supplies (DC/DC converter). Those generate
lower voltages which are needed locally within different blocks and are not generated by the main
power module.

3.3.7 Test Features

During the boot up certain self tests are performed to verify that the basic functionality is OK.
During normal operation CPU monitors (in the background):

• Operating voltages
• Cooling fans and temperature inside the NE
• Memory access (DRAMs, FLASH)
Naturally the NE has a watchdog to reset itself in case of a fatal failure in the CPU subsystem.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

32
3 Baseboard

3.4 Interfaces

An interface provides a physical connection to the network. Each interface has its own
media-specific components such as a framer or MAC and physical media interface device or
transceiver. They perform control functions according to the media type.

An interface typically:

• Receives incoming signal from the network


• Extracts payload (packets)
• Forwards ingress packets to NPU
• Receives egress packets from NPU
• Includes framing and other needed signaling
• Transmits outgoing signal to network
Tellabs 8607 access switch has two types of interfaces:

• An interface located on a pluggable LM


• A fixed interface i.e. an interface integrated on to the baseboard

3.4.1 Line Modules

A line module installed in any of the three slots M0, M1 and M2 provides a physical connection to
the network. Typically each media type has its own dedicated line module. The supported media
types are:

DSL

• 4xSHDSL LM
• 2xADSL LM
Ethernet

• 8x10/100BASE-TX LM
PDH/multiservice

• 8xchE1/chT1 LM
All line modules are of pluggable type, thus it is possible to install later a new line module to any
empty slot, or replace an existing one. An empty line module slot must be shielded with a cover plate.

The following table shows line module equipping recommendation principles for Tellabs 8607
access switch.

Line Module Type Maximum Limitations


Number
4xSHDSL 3 None
2xADSL 1 Can be used only in slot M0.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

33
3 Baseboard

Line Module Type Maximum Limitations


Number
8x10/100BASE-TX 1 When the 8x10/100BASE-TX LM is installed,
only one xDSL LM is allowed.
8xchE1/chT1 2 None
Empty 3 None, they are optional.

The following table outlines the legal combination of LM equipping in Tellabs 8607 access switch.

Line Module Equipping Combinations


4xSHDSL 8xchE1/chT1 8x10/100BASE-TX
4xSHDSL 4xSHDSL 8xchE1/chT1
4xSHDSL 4xSHDSL 4xSHDSL
8xchE1/chT1 8xchE1/chT1 4xSHDSL
8xchE1/chT1 8xchE1/chT1 8x10/100BASE-TX
4xSHDSL 8xchE1/chT1 Empty
2xADSL 8xchE1/chT1 8x10/100BASE-TX
2xADSL 4xSHDSL 8xchE1/chT1
2xADSL 4xSHDSL 4xSHDSL
2xADSL 8xchE1/chT1 8xchE1/chT1
Empty Empty Empty

2xADSL LM can be used only in slot M0 of Tellabs 8607 access switch! Other LMs do not
have slot place restrictions. Also when the 8x10/100BASE-TX LM is installed, only one xDSL
LM is allowed.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

34
3 Baseboard

3.4.2 Fixed Interfaces

The Tellabs 8607 access switch provides several fixed interfaces that are integrated on the baseboard
of the NE.

Fig. 9 Tellabs 8607 Access Switch Fixed Interfaces

Ethernet Interfaces

Tellabs 8607 access switch supports two independent fixed Gigabit Ethernet user interfaces. Both
interfaces can operate in either electrical mode at triple speed, e.g. 10/100BASE-TX/1000BASE-T
through an RJ-45 connector (auto-negotiation and automatic MDI/MDIX crossover is supported at
all speeds); or an optical SFP transceiver can be used and set the interface to operate in optical mode
replacing the electrical port (exclusive operation).

The electrical Ethernet ports are designed for intra-building use only. They are not meant
for external connections.

Main Features

An Ethernet interface provides the following main functional features:

• SFP type optical transceiver for 100/1000BASE-X


• Fixed RJ-45 connector for 10/100BASE-TX/1000BASE-T
• Synchronous Ethernet support
• 100/1000 Mbps full duplex
• Frame integrity validation
• Flow control support
• Auto-negotiation supported per port

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

35
3 Baseboard

• Automatic MDI/MDIX crossover


• Supports line loops (back to line) and equipment loops (back to system) per interface
• Automatic PAUSE frame generation and termination
• Packet statistic and performance monitoring per port (RMON)
• Two green status LEDs per port

Station Clock Input and Output

Tellabs 8607 access switch provides station clock input and output ports. The SCI is intended to be
connected to an external reference clock source, the SCO outputs the NE clock to the next device.
The E1 timing is 2048 kHz [G.703] clock or 2048 kbps signal, the T1 timing is 1544 kbps DS1
signal with a clock rate of 1544 kHz. The interface type is unbalanced 75 ohm SMB connector,
however symmetrical 100 or 120 ohm interfaces are possible with an external balun panel.

External Alarms

The external alarm interface is used for user configurable outputs and inputs. It provides an output
with solid state relay contacts and four inputs for external voltage free contacts, for example relays.
Typically an input could be connected to a power off relay in an external local device, enabling the
user to monitor possible remote faults.

An output is similar to a conventional relay. It has three pins; common (COM), normally closed
(NC) and normally open (NO) pins. The configuration is carried through CLI or Tellabs 8000
network manager. If the NE is not powered, there is a connection between the NC and COM pins.

Fig. 10 Alarm Output Logical Structure

The input consists of a comparator and protecting circuits. When the input is connected below the
threshold voltage, for example, to ground by an external device (relay), the state of the input is
considered to be closed, otherwise open.

CLI

Tellabs 8607 access switch can be locally controlled and managed through the asynchronous serial
interface (RS-232 type).

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

36
3 Baseboard

3.4.3 SFP Transceivers

WARNING: Optic operation should be verified by observing the status LEDs. Do not look into
the laser or fiber to verify operation. See also Safety Notes.

Optical Transceivers

The Tellabs 8600 system uses Small Form-Factor Pluggable (SFP) optical transceivers in the optical
interfaces.

An SFP optical transceiver is a hot-swappable input/output device that links a port on an optical
module with the fiber-optic network. For each application a certain type of SFP is required. You can
install or remove the SFP while the device is operating.

The connector type of the Tellabs 8600 system optical transceiver modules is LC duplex, see Fig. 11.

Fig. 11 LC Connectors

Fig. 12 shows a picture of a SFP optical transceiver, see chapter SFPs Used in Tellabs 8600 System
on models for various distances.

Fig. 12 Small Form-Factor Pluggable Optical Transceiver

Only Tellabs supplied and approved lasers should be used. If any other lasers or lasers from
any other source than Tellabs are used, the use thereof will be solely at the customer´s risk,
and the laser class, compatibility with the laser safety and EMC standards must be checked.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

37
3 Baseboard

Fig. 13 Class 1 Laser Product

When using an SFP with a high launch power in short distances, it may be required to decrease
the launch power by using an online optical attenuator or an attenuating optical cable in order to
meet the input power range.

Check that the operational temperature range of the SFP module is suitable for the installation
environment. Note that the temperature of the SFP case will be approximately 15 degrees
higher than ambient temperature.

Electrical Transceivers

The Tellabs 8600 system uses Small Form-Factor Pluggable (SFP) transceivers also in some
electrical interfaces. An SFP transceiver is a hot-swappable input/output device that links a port
on a transceiver module with the network. For each application a certain type of SFP is required.
You can install or remove the SFP while the device is operating.

The connector type of the Tellabs 8600 system electrical transceiver modules is RJ-45 or DIN
1.0/2.3. See chapter SFPs Used in Tellabs 8600 System on models for various distances.

Fig. 14 DIN and RJ-45 Connectors

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

38
3 Baseboard

Fig. 15 Small Form-Factor Pluggable Electrical Transceiver with RJ-45

Check that the operational temperature range of the SFP module is suitable for the installation
environment. Note that the temperature of the SFP case will be approximately 15 degrees
higher than ambient temperature.

SFPs Used in Tellabs 8600 System

The optical cable types are:

• Standard SM means fiber according to ITU-T specification G.652


• Dispersion shifted SM means fiber according to ITU-T specification G.653

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

39
40

Tellabs ® 8607 Access Switch FP1.1 Reference Manual


Tellabs ® 8600 Managed Edge System

3 Baseboard
Fast Ethernet Transceivers (100BASE)
Application Cable Wavelength Average Input Distance Connectors Allowed SFP Module
Type (nm) Launch Power SFP Case Order Code
Power Range Temperature
(dbm) (dbm) Range
100BASE- 50 & 62.5 1280 – 1380 -22 to -14 -14 to -29 2 km Duplex LC -40°...+85° C 81.86Z155MMFX02-R5
FX µm MM
100BASE- Standard 1261 – 1360 -15 to -8 -8 to -28 15 km Duplex LC -40°...+85° C 81.86Z155MSS111-R5
LX10 SM
100BASE-X Standard 1263 – 1360 -5 to 0 -10 to -34 40 km Duplex LC -40°...+85° C 81.86Z155MSL114-R5
SM
76.8611-40067A
© 2010 Tellabs.
© 2010 Tellabs.
76.8611-40067A Gigabit Ethernet Transceivers (1000BASE)
Application Cable Wavelength Average Input Distance Connectors Allowed SFP Module
Type (nm) Launch Power SFP Case Order Code
Power Range Temperature
(dbm) (dbm) Range
1000BASE-T Twisted — — — 100 m Compact 0°...+85° C 81.86Z001GET100-R5
Pair RJ-45
Copper
1000BASE-SX 50 & 62.5 770 – 860 -9.5 to 0 0 to -17 500 m Duplex LC -20°...+85° C 81.86Z001GMSX55-R5
µm MM
1000BASE- Standard 1270 – 1355 -9.5 to -3 -3 to -20 10 km Duplex LC -40°...+85° C 81.86Z001GSLX10-R5
LX10 SM
1000BASE-ZX Standard or 1500 – 1580 0 to 5 0 to -23 80 km Duplex LC -5°...+70° C 81.86Z001GSZX80-R5
dispersion
shifted SM
1000BASE- Standard or 1470 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS4780-R5
ZX-CWDM dispersion
shifted SM
1000BASE- Standard or 1490 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS4980-R5
ZX-CWDM dispersion
shifted SM
1000BASE- Standard or 1510 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS5180-R5
ZX-CWDM dispersion
shifted SM
Tellabs ® 8607 Access Switch FP1.1 Reference Manual

1000BASE- Standard or 1530 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS5380-R5


ZX-CWDM dispersion
shifted SM
1000BASE- Standard or 1550 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS5580-R5
Tellabs ® 8600 Managed Edge System

ZX-CWDM dispersion
shifted SM
1000BASE- Standard or 1570 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS5780-R5
ZX-CWDM dispersion
shifted SM

3 Baseboard
41
42

Tellabs ® 8607 Access Switch FP1.1 Reference Manual


Tellabs ® 8600 Managed Edge System

3 Baseboard
Application Cable Wavelength Average Input Distance Connectors Allowed SFP Module
Type (nm) Launch Power SFP Case Order Code
Power Range Temperature
(dbm) (dbm) Range
1000BASE- Standard or 1590 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS5980-R5
ZX-CWDM dispersion
shifted SM
1000BASE- Standard or 1610 ± 6.5 nm -2 to 3 -3 to -25 80 km Duplex LC -5°...+70° C 81.86Z001GS6180-R5
ZX-CWDM dispersion
shifted SM
76.8611-40067A
© 2010 Tellabs.
3 Baseboard

SFP Module Max. Power Consumption


81.86Z155MSS111-R5 0.9 W
81.86Z155MSL114-R5 0.9 W
81.86Z155MMFX02-R5 1.0 W
81.86Z001GMSX55-R5 0.7 W
81.86Z001GSLX10-R5 0.9 W
81.86Z001GET100-R5 1.2 W
81.86Z001GS4780-R5 0.9 W
81.86Z001GS4980-R5 0.9 W
81.86Z001GS5180-R5 0.9 W
81.86Z001GS5380-R5 0.9 W
81.86Z001GS5580-R5 0.9 W
81.86Z001GS5780-R5 0.9 W
81.86Z001GS5980-R5 0.9 W
81.86Z001GS6180-R5 0.9 W
81.86Z001GSZX80-R5 1.0 W

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

43
3 Baseboard

3.5 Front Panel and Connectors

3.5.1 Optical Ethernet Interface

The 100/1000BASE-X Ethernet interface is according to [IEEE 802] and the flow control is full
duplex. The transceiver is of an SFP type. More information on the SFPs approved by Tellabs is
available in chapter 3.4.3 SFP Transceivers.

Fig. 16 SFP Connector

Cabling

The 100/1000BASE-X interface supports 50 µm or 62.5 µm multimode fiber or single mode fiber
depending on installed transceiver type.

Laser Safety

See more on laser safety in chapter 3.4.3 SFP Transceivers.

Laser safety [IEC60825-1, A1, A2]


[IEC60825-2]

3.5.2 Electrical Ethernet Interface

The 10/100BASE-TX/1000BASE-T Ethernet interface is according to [IEEE 802] and the flow
control is half or full duplex. The connector type is RJ-45.

Fig. 17 RJ-45 Connector

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

44
3 Baseboard

RJ-45 Connector Pin Map


Pin PMA Signal Name (MDI-X)
1 BI_DB+
2 BI_DB-
3 BI_DA+
4 BI_DD+
5 BI_DD-
6 BI_DA-
7 BI_DC+
8 BI_DC-

Cabling

10/100BASE-TX/1000BASE-T supports FTP CAT5E or better cables.

3.5.3 Station Clock Input and Output Interface

The connector type is SMB.

Fig. 18 SMB Connector

SMB Connector Pin Map


Center pin, upper SMB G.703 Signal in (SCI)
Center pin, lower SMB G.703 Signal out (SCO)
Shield Ground

Cabling

For optimal performance, a 75 Ω shielded coaxial cable should be used. The maximum allowable
line attenuation for the cables is 6 dB @ 2.048 MHz.

3.5.4 CLI Interface

The asynchronous serial interface for CLI is according to [EIA/TIA-232-E]. The baud rate for this
interface is 38400 bps. The connector type is RJ-45.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

45
3 Baseboard

Fig. 19 RJ-45 Connector

RJ-45 CLI Connector Pin Map


Pin Signal Name
1 —
2 —
3 TxD
4 Ground
5 Ground
6 RxD
7 —
8 —

3.5.5 External Alarm Interface

The connector type is RJ-45.

Fig. 20 RJ-45 Connector

RJ-45 External Alarm Interface Pin Map


Pin Signal Name
1 Input 1
2 Input 2
3 Input 3
4 Input 4
5 Ground
6 Normally Open contact (NO)

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

46
3 Baseboard

Pin Signal Name


7 Common (COM)
8 Normally Closed contact (NC)

Cabling

For optimal performance, FTP CAT5 or better cables should be used.

3.6 LEDs

3.6.1 NE Status LEDs

There are three LEDs to indicate the NE status and one for the power OK status.

LED Name Color States


Local Alarm RED ON when NE itself has a fault.
BLINKING when manually set to forced blinking.
OFF otherwise.
Remote Alarm YELLOW ON when online and NE detects or suspects a fault in
another NE or remote site.
BLINKING during following operations:
1) Boot-up sequence
2) Inventory create
3) Inventory (backup) restoration
4) Manually set to forced blinking.
OFF otherwise.
OnLine GREEN ON when NE is online (it is “up” meaning successful
boot-up sequence finished and startup permission
granted). Note that online NE may still contain errors.
BLINKING when manually set to forced blinking.
OFF otherwise.
Power GREEN ON when NE power is ON.
OFF otherwise.

3.6.2 Ethernet LEDs

There are two LEDs to indicate the Ethernet port status.

LED Name Color States


Link/Activity GREEN ON when Ethernet link is up.
BLINKING when Ethernet link is up and there is
transmit or receive activity.
OFF when Ethernet link is down or in shutdown state.
Online GREEN ON when administrative status for Ethernet interface
is online.
BLINKING when manually set to forced blinking.
OFF when administrative status for Ethernet interface is
shutdown or Ethernet link is down.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

47
3 Baseboard

3.7 Technical Specifications

3.7.1 Baseboard Technical Specifications

Power consumption Typical 19.6 W


Maximum 27.5 W
Line modules are not included
Number of line modules 3
Other modules CPU subsystem

3.7.2 Interfaces Technical Specifications

Ethernet Specifications

Optical Mode
Interface — 100BASE-X SFP interfaces
— 1000BASE-X SFP interfaces
see chapter 3.4.3 SFP Transceivers for more
information on SFP module types
Number of ports Max. 2
Cabling SFP cables: see chapter 3.4.3 SFP Transceivers
Synchronization Synchronized to NE clock
MTU Max. 1836
VLANs Max. 512 VLANs per NE and 256 per interface
MAC filters Erroneous frames;
Short and too long frames,
Flow control and overflow
Loopbacks Line and Equipment

Electrical Mode
Interface 10/100BASE-TX/1000BASE-T interface: RJ-45
connector
Number of ports Max. 2
Auto-negotiation, MDI-X Supported
Cabling 10/100BASE-TX/1000BASE-T: CAT-5E or better
FTP, 100 m max.
Synchronization Synchronized to NE clock
MTU Max. 1836
VLANs Max. 512 VLANs per NE and 256 per interface

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

48
3 Baseboard

MAC filters Erroneous frames;


Short and too long frames;
Flow control and overflow
Loopbacks Equipment

Timing Block Specifications

Technical Specifications
Frequency accuracy in free running condition ± 4.6 ppm
Pull-in range ± 4.6 ppm
Wander in locked mode ITU-T [G.813] option 1,
Stratum-3 [GR-1244-CORE]
Noise transfer bandwidth 3 Hz in ITU-T mode
< 0.1 Hz in Stratum-3 mode
Phase transient response ITU-T [G.813] option 1,
Stratum-3 [GR-1244-CORE]

Technical Specifications of SCI and SCO Ports


Frequency 2048 kHz ± 4.6 ppm when locked to timing block
1544 kHz ± 4.6 ppm when locked to timing block
Electrical characteristics According to [G.703]
According to [T1.102]

Nominal impedance 75 Ω unbalanced


100 Ω and 120 Ω balanced with external balun
Modes Framed 2048 kbps (G.703), NRZ 2048 kHz
Framed 1544 kbps signal
Attenuation margin 0 to 6 dB at 2048 kHz
Loss of input clock signal detection According to [G.775]
Connector type SMB (unbalanced male)

CLI and External Alarm Interface Specifications

Technical Specifications of External Alarm Interface


External alarm input characteristics Considered closed when
input < 1.5 V
open when input > 2.5 V
Max. voltage 12 V
External alarm output characteristics Max. 59 V
Max. 150 mA (per pin)
Contact resistance 10...30 Ω
Asynchronous CLI port RS-232
Connector type RJ-45

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

49
4 Power Modules

4 Power Modules
Tellabs 8607 access switch can be fed by -48 Vdc or +24 Vdc battery voltage. The same DC power
module can be used for both battery voltages.

4.1 DC Power Module

4.1.1 Overview

Tellabs 8607 access switch provides two DC power modules on the front side of the NE. If
redundant power feeding is required, it is achieved by installing DC power modules to both slots.
An empty power module slot must be shielded with a cover plate. The nominal input voltage is
-48 Vdc or +24 Vdc. The DC power module has a DC/DC converter with 12 Vdc output. The output
is stabilized and galvanically isolated from the input.

The 12 Vdc output of the DC power module is used to supply the cooling fans and it is routed to the
baseboard via the fan backplane module and the actual locally operating voltages are derived on
the baseboard by on board DC/DC converters. Some line modules require operating voltages that
are not present on the baseboard, therefore these voltages are generated locally on the individual
line module.

The DC power module features are the following:

• Input over-current protection (fuse)


• EMI filtering
• Input transient overvoltage protection
• DC/DC conversion; -48 Vdc or +24 Vdc/12 Vdc
• Isolation between input and output circuitry
• Output voltage monitoring
• Input voltage status LED
• Output overload and short circuit protection
• Polarity protection
• Holdup time provider
• Dying gasp

4.1.2 Interfaces

The input connector is located on the front side of the DC power module. The 12 Vdc output
voltage and I2C-bus are connected from the DC power module to the baseboard through the fan
backplane module.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

50
4 Power Modules

4.1.3 Operation

The input voltage is fed through the input filter and fuse to the input capacitors. The DC power
module also includes inrush current limiter for the capacitors and transient overvoltage protection.
Redundancy can be realized by using two DC power modules in the enclosure. There is no active
current sharing between the two DC power modules. However, the current will normally be divided
rather equally between the two DC power modules. One DC power module is able to supply the
whole current required by Tellabs 8607 access switch. The output voltage of the DC power module
has current limit circuit.

4.1.4 Front Panel and Connectors

The following figure shows the DC power module front panel.

Fig. 21 Tellabs 8607 Access Switch DC Power Module Front Panel

4.1.5 Input Fault Detection and LED

On the DC power module there is a voltage monitor for input voltage detection. If the input voltage
after the fuse is missing or too low, an alarm is forwarded to the baseboard, and a LED indicates the
input voltage status.

LED Name Color States


Battery voltage GREEN ON when Input voltage is valid
OFF otherwise.

4.1.6 Technical Specifications

Dimensions 85 x 21.8 x 254 mm (w x h x d)


Weight 177 g
Output specifications 12 Vdc output voltage
5 A output current
60 W maximum power
Power consumption Typical 5.5 W
Maximum 13 W
Alarms Battery voltage monitoring

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

51
5 Line Modules

5 Line Modules

5.1 2-Port ADSL Line Module (2xADSL)

5.1.1 Overview

The 2-port bondable 4-wire ADSL line module (2xADSL LM) provides one ADSL2/2+ interface
with one ADSL line using two wires or one bonded ADSL2+ interface with two ADSL lines using
four wires.

2xADSL LM provides one logical packet forwarding interface (IP/MPLS interface) and two
physical 2-wire DSL line interfaces. If 2xADSL LM is configured to ATM bonding mode, both the
DSL1 and DSL2 pairs are used. In unbonded mode only the DSL2 pair is used and the DSL1 pair is
unused. Both DSL pairs are connected using a single RJ-14 connector. 2xADSL LM provides a
physical link between the network and the network processor located in the baseboard of Tellabs
8607 access switch.

2xADSL LM can be used only in slot M0 of Tellabs 8607 access switch!

In 2xADSL LM both the DSL1 and DSL2 lines are available in the same connector.

2xADSL LM interface ports are protected against lightning surge overvoltage of up to 1500 V
longitudinal and metallic (cm and dm) mode (1.2/50 and 10/700 μs) without additional external
primary protection devices. The ports fulfill the isolation requirements of [IEC60950-1]
(1500 Vac rms 50/60 Hz common mode).

For protection against higher voltages (such as lightning surges), coordination between the
secondary protection (within the equipment) and primary protection (external) must be used.
The primary protection devices, such as Gas Discharge Tubes (GDT), must operate before the
voltage exceeds the maximum tolerance of the secondary protection devices within the equipment
(1500 V (1.2/50 and 10/700 μs)).

When using GDTs as primary protection devices, connect a GDT from both the Tip and Ring
lines to ground potential.

Main Features

The 2xADSL LM provides the following main functional features:

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

52
5 Line Modules

• A four-wire RJ-14 connector


• One green status LED per interface
• Two ADSL2/2+ Annex L and Annex M ports
• ITU-T [G.998.1] ATM bonding
• DELT, Dual Ended Loop Test
• Bit swapping
• SRA rate adaptation
• Support for one ATM PVC, ATMF UNI 3.1/4.0 PVC
• [RFC1483]/[RFC2684] MPOA over AAL5
• LLC multiplexing
• I.610 OAM F5 loopback response

5.1.2 Front Panel and Connectors

The 2xADSL LM has one RJ-14 line connector, on the left in Fig. 22, the right-most connector is
the test interface for Tellabs internal use only.

Fig. 22 2xADSL LM Front Panel

The following table presents the 2xADSL LM interface connector pinout.

RJ-14 Line Connector


Pin Signal
1 No connection
2 Ring (DSL2)
3 Ring (DSL1)
4 Tip (DSL1)
5 Tip (DSL2)
6 No connection

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

53
5 Line Modules

The test interface of 2xADSL LM is disabled and only for Tellabs internal use!

RJ-45 Debug Connector


Pin Signal
1 TD1P
2 TD1N
3 3.3V
4 Ground
5 No connection
6 No connection
7 RD1P
8 RD1N

5.1.3 LEDs

There is one LED per port showing the interface status. The location of LEDs are shown in Fig. 22.

LED Name Color States


DSL1 line GREEN OFF, when the line is unprovisioned or not activated.
SLOW BLINKING, when the line is configured and
activated but not actively training with the far end
modem (activation).
FAST BLINKING, when the line is configured,
activated and currently in training process with the far
end modem (initialization).
SOLID GREEN, when the line is in showtime.
DSL2 line GREEN OFF, when the line is unprovisioned or not activated.
SLOW BLINKING, when the line is configured and
activated but not actively training with the far end
modem (activation).
FAST BLINKING, when the line is configured,
activated and currently in training process with the far
end modem (initialization).
SOLID GREEN, when the line is in showtime.
POWER GREEN OFF, when power off or LM not activated.
SOLID GREEN when power on and the LM has been
activated.
ALARM RED SOLID RED, Failing power on diagnostics.
LAN GREEN Status of Test Interface.
OFF, when there is no Ethernet LAN connection.
SOLID GREEN, when Ethernet connection has been
established.
BLINKING, when data is passing through the port.
ACT GREEN Lit, when there is activity between LM and 8607
chassis.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

54
5 Line Modules

5.1.4 Cabling

The 2xADSL LM supports 100 Ω unshielded twisted pair cable, CAT5.

5.1.5 Technical Specifications

Dimensions 82.9 x 33.8 x 144.5 mm (w x h x d)


Weight 245 g
Power consumption Typical 10 W
Maximum 12 W
Operating conditions [ETSI EN 300 019-1-3] Class 3.25
Temperature range: -5° C to +45° C (+23° F to +113° F).
Relative humidity: 5% to 95%.
Interface type 100 Ω, 2 twisted-pair wires
Electrical interface ADSL: 1 RJ-14 connector for 2 ADSL2+ ports
Number of ports 1
ADSL line rate • ITU G.992.1 ADSL (G DMT) mode max 12 Mbps
• ITU G.922.3 ADSL2 mode max 12 Mbps
• ITU G.922.5 ADSL2+ mode max 24 Mbps
Cabling 100 Ω +/-10%, 2 x unshielded twisted pair, CAT5

5Condensation is not allowed.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

55
5 Line Modules

5.2 4-Port SHDSL Line Module (4xSHDSL)

5.2.1 Overview

The main function of the 4xSHDSL Line Module (LM) is to provide four symmetrical and
bidirectional 135 Ω SHDSL interfaces. 4xSHDSL LM provides a physical link between the network
and the network processor located in the baseboard of Tellabs 8607 access switch.

4xSHDSL LM interface ports are protected against lightning surge overvoltage of up to 1500 V
longitudinal and metallic (cm and dm) mode (1.2/50 and 10/700 μs) without additional external
primary protection devices. The ports fulfill the isolation requirements of [IEC60950-1]
(1500 Vac rms 50/60 Hz common mode).

For protection against higher voltages (such as lightning surges), coordination between the
secondary protection (within the equipment) and primary protection (external) must be used.
The primary protection devices, such as Gas Discharge Tubes (GDT), must operate before the
voltage exceeds the maximum tolerance of the secondary protection devices within the equipment
(1500 V (1.2/50 and 10/700 μs)).

When using GDTs as primary protection devices, connect a GDT from both the Tip and Ring
lines to ground potential.

Main Features

The 4xSHDSL LM provides the following main functional features:

• Four independent G.SHDSL interfaces that are compliant to:


• ITU-T recommendations [G.991.2]
• EFM according to [IEEE802.3]
• A four pairs RJ-45 connector and wiring according to TIA568A
• Line termination impedance 135 Ω
• Supports SHDSL.bis, payload bit rate from 192 kbps to 5.7 Mbps
• Interoperable with standard compliant SHDSL transceivers
• Recovered clock from any port can be selected as NE reference clock
• Equipment modes
• STU-R
• Supports dying gasp and uses power status bits for signalling
• Supports follow channel bundling modes:
• PAF functionality from 1 group of 4 pairs to 4 group of 1 pair according to [IEEE802.3]
• One bicolor (amber and green) status LED per interface

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

56
5 Line Modules

5.2.2 Front Panel and Connectors

The 4xSHDSL LM has one RJ-45 connector. The interfaces are numbered from 0 to 3.

Fig. 23 4xSHDSL LM Front Panel

The following table presents the 4xSHDSL LM interface connector pinout.

Port RJ-45 Pin Signal


0 4 Tip
0 5 Ring
1 3 Tip
1 6 Ring
2 1 Tip
2 2 Ring
3 7 Tip
3 8 Ring

5.2.3 LEDs

There is one bicolor LED per port showing interface statuses. The location of LEDs are shown
in Fig. 23.

LED Color States

OFF OFF when interface is in INACTIVE/SHUTDOWN state.


AMBER When interface is configured and activated but not actively trained with
the far end modem
Blinking AMBER When interface is configured , activated and currently in training process
with the far end modem
GREEN When interface is configured and the line is in showtime

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

57
5 Line Modules

5.2.4 Cabling

The 4xSHDSL LM supports 135 Ω shielded twisted pair cable.

To fulfil EMC requirements use only shielded cables. The screen of the shielded interface
cable must be terminated to ground.

An adequate signal-to-noise margin is required for achieving the maximum allowable cable
attenuation figure.

5.2.5 Technical Specifications

Dimensions 82.9 x 33.8 x 144.5 mm (w x h x d)


Weight 100 g
Power consumption Typical 2.8 W
Maximum 3.6 W
Operating conditions [ETSI EN 300 019-1-3] Class 3.26
Temperature range: -40° C to +65° C (-40° F to +149° F).
Relative humidity: 5% to 95%.
Interface type 135 Ω symmetrical, 1 twisted-pair wires per port
Electrical interface G.SHDSL: RJ-45 connector
Number of ports 4
Ethernet framing EFM [IEEE802.3] TPS-TC
Payload data rate • From 192 kbps up to 5.7 Mbps per port
• Rate adaptable according to [G.994.1]
Cabling 135 Ω twisted pair
Synchronization SEC according to [G.813] and Stratum-3 according to [GR-1244-CORE]
Clock source can be at minimum SEC or Stratum-3 level clock
Synchronized to NE clock or Free running
Equipment modes STU-R

6Condensation is not allowed.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

58
5 Line Modules

5.3 8-Port Fast Ethernet Line Module (8x10/100BASE-TX)

5.3.1 Overview

The main function of the 8x10/100BASE-TX Line Module (LM) is to provide eight independent
electrical 10BASE-T or 100BASE-TX user interfaces. The LM provides a physical link between the
network and the data plane and forwarding (NPU) in Tellabs 8607 access switch.

The 8x10/100BASE-TX LM is designed for indoor use only. It is not meant for external
connections.

Main Features

The 8x10/100BASE-TX LM provides the following main functional features:

• Eight independent and dual speed (10/100 Mbps) 10/100BASE-TX interfaces


• Full duplex or half duplex (CSMA/CD) operation per interface
• RJ-45 connectors
• Generic microprocessor interface for configuration, control and status monitoring
• Frame integrity validation
• Synchronous Ethernet support
• Recovered receive clock from any of the 100 Mbps ports can be selected as NE reference
clock
• Egress transmit signal in all ports synchronized to NE clock
• Auto-negotiation supported per interface
• Automatic MDI/MDIX crossover
• Statistic and performance monitoring
• One bicolor status LED per interface
• Serial EEPROM for the factory parameters
• Supports line loop (back to line) and equipment loop (back to system) per interface

CAUTION: Do not insert an RJ-11 (telephone) jack into a 8x10/100BASE-TX LM ports.


Equipment damage may result.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

59
5 Line Modules

5.3.2 Front Panel and Connectors

The interfaces are numbered from 0 to 7.

Fig. 24 8x10/100BASE-TX LM Front Panel

RJ-45 Connector Pin List


RJ-45 Pin Map PMA Signals, NIC Type PMA Signals, HUB Type
1 TX_D1+ RX_D1+
2 TX_D1- RX_D1–
3 RX_D2+ TX_D2+
4 - -
5 - -
6 RX_D2- TX_D2–
7 - -
8 - -

5.3.3 LEDs

There is one bicolor LED per each interface to indicate its status.

LED Color States


GREEN ON when link is up on the speed 100 Mbps.
BLINKING when TX or RX or either activities on the
100 Mbps.
OFF when administrative status for interface is offline.
YELLOW ON when links is up on the speed 10 Mbps.
BLINKING when TX or RX or either activities on the 10 Mbps.
OFF when administrative status for interface is offline.
Alternate Blinking Link is down and administrative status for interface is online.
GREEN-YELLOW

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

60
5 Line Modules

5.3.4 Cabling

The 8x10/100BASE-TX LM supports FTP CAT5 or better cables.

To fulfil the EMC requirements use only STP/FTP cabling.

5.3.5 Technical Specifications

Dimensions 82.9 x 33.8 x 145.2 mm (w x h x d)


Weight 150 g
Power consumption Typical 4.0 W
Maximum 4.6 W
Operating conditions [ETSI EN 300 019-1-3] Class 3.27
Temperature range: -40° C to +65° C (-40° F to +149° F).
Relative humidity: 5% to 95%.
Interface type 100 Ω symmetrical, 2 twisted-pairs per port
Electrical interface 10BASE-T or 100BASE-TX: RJ-45 connector
Number of ports 8
Auto MDI-X Supported
Cabling 100 Ω CAT5 or better FTP/STP:
Max. 90 m for FTP
Max. 90 m for STP
Synchronization Synchronized to NE clock
Main feature Parallel to Serial and Serial to Parallel MII Conversion FPGA+
PHYs
MTU Max. 1548 bytes
Loopbacks Equipment loop, Line loop
System interface bus 8bit @ 125MHz

7Condensation is not allowed.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

61
5 Line Modules

5.4 8-Port Channelized E1 / Channelized T1 Line Module


(8xchE1/chT1)

5.4.1 Overview

The main function of 8xchE1/chT1 Line Module (LM) is to provide eight symmetrical 120 Ω
short or long haul n x 64 kbps channelized E1 interfaces (2,048 Mbps), or alternatively, eight
symmetrical 100 Ω short or long haul n x 64 kbps channelized T1 interfaces (1,544 Mbps). The
operating mode is software-selectable.

8xchE1/chT1 LM provides a physical link between the network and the data plane and forwarding
(NPU) in the Tellabs 8607 access switch.

8xchE1/chT1 LM interface ports are protected against lightning surge overvoltage of up to


1500 V longitudinal and metallic (cm and dm) mode (1.2/50 and 10/700 μs) without additional
external primary protection devices. The ports fulfill the isolation requirements of [IEC60950-1]
(1500 Vac rms 50/60 Hz common mode).

For protection against higher voltages (such as lightning surges), coordination between the
secondary protection (within the equipment) and primary protection (external) must be used.
The primary protection devices, such as Gas Discharge Tubes (GDT), must operate before the
voltage exceeds the maximum tolerance of the secondary protection devices within the equipment
(1500 V (1.2/50 and 10/700 μs)).

When using GDTs as primary protection devices, connect a GDT from both the Tip and Ring lines
to ground potential. The Receive as well as the Transmit lines must be protected.

CAUTION: The 8xchE1/chT1 LM contains a built in protection circuitry based on ceramic


PTC-resistor. The protection function might be affected when touching the module with bare
hands. It is always recommended to wear gloves when handling the module.

The E1/T1 interfaces are designed and tested to withstand a 1.5 kV longitudinal and metallic
(cm and dm) mode surge pulse (1.2/50 µs and 10/700 μs) without any external protection
devices. If higher surge voltages are expected, external primary protection devices are
required. The firing voltage of the protection devices must be less than 1 kV and the devices
must be selected so that no signal quality degradation occurs.

Main Features

8xchE1/chT1 LM provides the following main functional features:

• 8 x symmetrical E1 or T1 interfaces (short or long haul)


• E1/T1 framing
• 8 independent RJ-45 connectors. Connector wiring according to RJ48c
• Line termination impedance 120 Ω for E1 and 100 Ω for T1

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

62
5 Line Modules

• Supports line loop and equipment loop capability


• Loop and node timing capability per interface
• Recovered 2,048/1,544 MHz clock from any port can be selected as reference clock for the Tim-
ing Block
• Per port-specific status/alarm LEDs – red, yellow and green for showing interface statuses

5.4.2 Front Panel and Connectors

8xchE1/chT1 LM has eight RJ-45 connectors. The interfaces are numbered from 0 to 7.

The connector wiring is according to RJ48c without ground pins 7 and 8. The body of the RJ-45
jack is shielded and grounded in order to make ground contact to the twisted pair cable shield which
is connected to the shielded body of the RJ-45 plug.

Fig. 25 8xchE1/chT1 LM Front Panel

For safety reasons, the 8xchE1/chT1 LM connectors cannot be connected to the Ethernet
interface. Be careful not to misconnect the cables.

The following table presents 8xchE1/chT1 LM interface connector pinout.

Pair RJ-45 Pin Signal


1 1 Receive Ring
1 2 Receive Tip
- 3 No connection
2 4 Transmit Ring
2 5 Transmit Tip
- 6 No connection
- 7 No connection
- 8 No connection

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

63
5 Line Modules

5.4.3 LEDs

There are three LEDs to indicate the port status. Physically the LEDs are integrated in the RJ-45
connector.

LED Name Color States

Alm RED ON when LOCAL ALARM (LOS/LOF/AIS)


BLINKING when manually set to forced blinking.
OFF when no errors or LM is in INACTIVE/SHUT-
DOWN state.
Online GREEN ON when administrative status for interface is online.
BLINKING when manually set to forced blinking.
OFF when administrative status for interface is
shutdown or PDH link is down.
Alm YELLOW ON when REMOTE ALARM (RAI)
OFF when no errors or LM is in INACTIVE/SHUT-
DOWN state.

5.4.4 Cabling

For optimal performance, 120 Ω shielded twisted pair cable should be used for E1 and 100 Ω
shielded twisted pair cable for T1. The maximum allowable line attenuation is 30 dB @ 1.024 MHz
for E1 cables and 30 dB @ 772 kHz for T1 cables, which define the maximum cable lengths.

An adequate signal-to-noise margin is required for achieving the maximum allowable cable
attenuation figure.

CAUTION: To reduce the risk of fire, use only the 26 AWG or larger telecommunication line
cord in Tellabs 8607 access switch 8xchE1/chT1 line modules.

CAUTION: Do not insert RJ-11 (telephone) plug into E1/T1 ports. Equipment damage may
result.

CAUTION: Do not connect or disconnect the RJ45 cables at temperature under -20°C.
Equipment damage may result.

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

64
5 Line Modules

5.4.5 Technical Specifications

Dimensions 82.9 x 33.8 x 145.2 mm (w x h x d)


Weight 190 g
Power consumption Typical 2.5 W
Maximum 3.5 W
Operating conditions [ETSI EN 300 019-1-3] Class 3.28
Temperature range: -40° C to +65° C (-40° F to +149° F).
Relative humidity: 5% to 95%.
Interface E1 120 Ω / T1 100 Ω symmetrical interfaces: RJ-45
connector
Number of ports 8
Electrical interface G.703 / T1.102, T1.403
Line coding HDB3 / B8ZS
E1 framing Unframed mode and
G.704 multi frame mode and
G.706 CRC-4 multi frame modes
DS1 framing Unframed mode and
SF and ESF modes
Maximum line attenuation E1: 30 dB @ 1 MHz
T1: 30 dB @ 772 kHz, Line length and line build-out
support
Cabling E1: 120 Ω shielded twisted pair
T1: 100 Ω shielded twisted pair
Synchronization Synchronized to NE clock or Loop timing

Function E1: 2,048 Mbps, Full duplex


T1: 1,544 Mbps, Full duplex
Loopbacks Equipment loop, Line loop
Overvoltage protection [EN 300 386] Other than telecom port for outdoor lines

8Condensation is not allowed.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

65
References

References
The table below lists Tellabs 8600 network element specific references.

Reference Description
[AF-PHY-0086-000] AF-PHY-0086-000 (1997-07), Inverse Multiplexing for ATM (IMA)
Specification Version 1.0
[AF-PHY-0086-001] AF-PHY-0086-001 (1999-03), Inverse Multiplexing for ATM (IMA)
Specification Version 1.1
[draft-ietf-bfd-base-03] draft-ietf-bfd-base-03.txt (7/2005), Bidirectional Forwarding
Detection
[draft-ietf-bfd-v4v6-1hop] draft-ietf-bfd-v4v6-1hop-04.txt (10/2005), BFD for IPv4 and IPv6
(Single Hop)
[draft-ietf-pwe3-pw-mib-10] draft-ietf-pwe3-pw-mib-10.txt (2007-02), Pseudo Wire (PW)
Management Information Base
[draft-ietf-pwe3-tdm-pw-mib-] draft-ietf-pwe3-tdm-mib-06.txt (2006-09), Managed Objects for
TDM over Packet Switched Network (PSN)

[draft-ietf-pwe3-vccv] draft-ietf-pwe3-vccv-bfd-07.txt (2009-07) Bidirectional Forwarding


Detection (BFD) for the Pseudowire Virtual Circuit Connectivity
Verification (VCCV)
[EIA/TIA-232-E] EIA/TIA-232-E (2000-01), Interface between data terminal
equipment and data circuit-terminating equipment employing serial
binary data interchange
[EN 300 166] EN 300 166 (1993-08), Transmission and multiplexing (TM);
Physical and electrical characteristics of hierarchical digital interfaces
for equipment using the 2048 kbps – based plesiochronous or
synchronous digital hierarchies
[EN 300 386] EN 300 386 (2005), Electromagnetic compatibility and radio
spectrum matters (ERM); Telecommunication network equipment;
Electromagnetic compatibility (EMC) requirements
[ETSI EN 300 019-1-1] ETSI EN 300 019-1-1 v2.1.4 (2003-04), Environmental conditions
and environmental tests for telecommunication equipment, Part 1-1:
Classification of environmental conditions, storage
[ETSI EN 300 019-1-2] ETSI EN 300 019-1-2 v2.1.4 (2003-04), Environmental conditions
and environmental tests for telecommunication equipment, Part 1-2:
Classification of environmental conditions, transportation
[ETSI EN 300 019-1-3] ETSI EN 300 019-1-3 v2.2.2 (2004-07), Environmental conditions
and environmental tests for telecommunication equipment, Part 1-3:
Classification of environmental conditions, stationary use at weather
protected locations
[G.703] ITU-T Recommendation G.703 (1998-10), Physical/electrical
characteristics of hierarchical digital interfaces
[G.704] ITU-T Recommendation G.704 (1998-10), Synchronous frame
structures used at 1544, 6312, 2048, 8448 and 44 736 kbit/s
hierarchical levels

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

66
References

Reference Description
[G.775] ITU-T Recommendation G.775 (1988-10), Loss of signal (LOS),
alarm indication signal (AIS) and remote defect indication (RDI)
defect detection and clearance criteria for PDH signals
[G.813] ITU-T Recommendation G.813 (1996-08), Timing characteristics of
SDH equipment slave clocks (SEC)
[G.826] ITU-T Recommendation G.826 (2002-12), End-to-end error
performance parameters and objectives for international, constant
bit-rate digital paths and connections
[G.8262] ITU-T Recommendation G.8262 (2007-08), Timing Characteristics
of Synchronous Ethernet Equipment Slave Clock (EEC)
[G.8264] ITU-T Recommendation G.8264 (2008-02), Distribution of Timing
Through Packet Networks
[G.991.2] ITU-T Recommendation G.991.2 (2005), Single-pair high-speed
digital subscriber line (SHDSL) transceivers
[G.992.1] ITU-T Recommendation G.992.1 (2000-03), Asymmetric digital
subscriber line (ADSL) transceivers
[ITU G.992.1 Annex A] Annex A Specific requirements for an ADSL system operating in the
frequency band above POTS (1999-06)
[G.992.3] ITU-T Recommendation G.992.3 (2002-07), Asymmetric digital
subscriber line (ADSL) transceivers 2
[G.992.5] ITU-T Recommendation G.992.5 (2003-05), Asymmetric digital
subscriber line transceivers 2 plus (ADSL2+)
[G.994.1] ITU-T Recommendation G.994.1 (2007-02), Handshake procedures
for digital subscriber line (DSL) transceivers
[G.998.1] ITU-T Recommendation G.998.1 (2005-01), ATM-based multi-pair
bonding
[G.998.2] ITU-T Recommendation G.998.2 (2005-02), Ethernet-based
multi-pair bonding
[G.998.3] ITU-T Recommendation G.998.3 (2009-04), Asymmetric Digital
Subscriber Line Transceivers 2 (ADSL 2)
[G.998.5] ITU-T Recommendation G.998.5 (2009-01), Asymmetric Digital
Subscriber Line Transceivers – Extended Bandwidth ADSL 2 (ADSL
2Plus)
[GR-253] GR-253 (2005-12), Issue 4, Synchronous optical network (SONET)
transport systems: common generic criteria
[GR-499] GR-499 (2004), Transport Systems Generic Requirements (TSGR):
Common Requirements
[I.361] ITU-T Recommendation I.361 (1999-02), B-ISDN ATM layer
specification
[I.363.5] ITU-T Recommendation I.363.5 (1996-08), B-ISDN ATM Adaptation
Layer specification: Type 5 AAL
[I.371] ITU-T Recommendation I.371 (2000-03), Traffic control and
congestion control in B-ISDN
[I.371.1] ITU-T Recommendation I.371.1 (2000-11), Guaranteed frame rate
ATM transfer capability
[I.432.1] ITU-T Recommendation I.432.1 (1999-02), B-ISDN user-network
interface – Physical layer specification: General characteristics

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

67
References

Reference Description
[I.610] ITU-T Recommendation I.610 (1999-02), B-ISDN Operation and
Maintenance Principles and Functions
[I.610Amend1] Amendment 1 (2000-03) to ITU-T Recommendation I.610, B-ISDN
Operation And Maintenance Principles And Functions
[I.610Corr1] Corrigendum 1 (2000-03) to ITU-T Recommendation I.610, B-ISDN
Operation And Maintenance Principles And Functions
[I.732] ITU-T Recommendation I.732 (2000-10), Functional characteristics
of ATM equipment
[IEC60825-1] IEC60825-1, A1, A2 (2001), Safety of laser products - Part 1:
Equipment classification, requirements and user’s guide
[IEC60825-2] IEC60825-2 (2004), Safety of laser products - Part 2: Safety of
optical fibre communication systems
[IEEE 802] IEEE Std 802-1990 – IEEE standards for local and metropolitan area
networks: Overview and architecture
[IEEE 802.1ad] IEEE Std 802.1ad-2005 – IEEE Standard for Local and metropolitan
area networks: Virtual Bridged Local Area Networks. Amendment 4:
Provider Bridges. Amendment to IEEE Std 802.1Q-2005.
[IEEE 802.1ag] IEEE Std 802.1ag-2007 – IEEE Standard for Local and metropolitan
area networks: Virtual Bridged Local Area Networks. Amendment 5:
Connectivity Fault Management.
[IEEE 802.1Q] IEEE Std 802.1Q-1998 – IEEE Standard for Local and Metropolitan
Area Networks: Virtual Bridged Local Area Networks
[IEEE 802.3] IEEE Std 802.3-2005 – IEEE Standard for Local and metropolitan
area networks – Specific Requirements - Part 3:Carrier sense multiple
access with collision detection (CSMA/CD) access method and
physical layer specifications
[IEEE 802.3ad] IEEE Std 802.3ad-2000 – IEEE Standard for Local and metropolitan
area networks – Clause 43, Aggregation of Multiple Link Segments
[RFC1027] RFC1027 (1987-10), Using ARP to implement transparent subnet
gateways
[RFC1142] RFC1142 (1990-02), OSI IS-IS Intra-domain Routing Protocol
[RFC1195] RFC1195 (1990-12), Use of OSI IS-IS for routing in TCP/IP and
dual environments
[RFC1662] RFC1662 (1994-07), PPP in HDLC-like framing
[RFC1771] RFC1771 (1995-03), A Border Gateway Protocol 4 (BGP-4)
[RFC1990] RFC1990 (1996-08), The PPP Multilink Protocol (MP)
[RFC2515] RFC2515 (1999-02), Definitions of Managed Objects for ATM
Management
[RFC2863] RFC2863 (2000-06), The Interfaces Group MIB (IF-MIB)
[RFC2865] RFC2865 (2000-12), Remote Authentication Dial In User Service
(RADIUS)
[RFC3036] RFC3036 (2001-01), LDP Specification
[RFC3153] RFC3153 (2001-08), PPP Multiplexing
[RFC3209] RFC3209 (2001-12), RSVP-TE: Extensions to RSVP for LSP tunnels
[RFC3270] RFC3270 (2002-05), Multi-protocol label switching (MPLS) support
of differentiated services

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

68
References

Reference Description
[RFC3518] RFC3518 (2003-04), Point-to-Point Protocol (PPP) Bridging Control
Protocol (BCP)
[RFC3564] RFC3564 (2003-07), Requirements for support of differentiated
services-aware MPLS traffic engineering
[RFC3606] RFC3606 (2003-11), Definitions of Supplemental Managed Objects
for ATM Interface
[RFC3630] RFC3630 (2003-09), Traffic engineering (TE) extensions to OSPF
version 2
[RFC3784] RFC3784 (2005-06), Intermediate System to Intermediate System
(IS-IS) Extensions for Traffic Engineering (TE)
[RFC3812] RFC3812 (2004-06), Multiprotocol Label Switching (MPLS) Traffic
Engineering (TE) Management Information Base (MIB)
[RFC4090] RFC4090 (2005–05), Fast Reroute Extensions to RSVP-TE for LSP
Tunnels
[RFC4379] RFC4379 (2006-02), Detecting Multi-Protocol Label Switched
(MPLS) Data Plane Failures
[RFC4385] RFC4385 (2006-02), Pseudowire Emulation Edge-to-Edge (PWE3)
Control Word for Use over an MPLS PSN
[RFC4447] RFC4447 (2006-04), Pseudowire Setup and Maintenance Using the
Label Distribution Protocol (LDP)
[RFC4448] RFC4448 (2006-04), Encapsulation Methods for Transport of
Ethernet over MPLS Networks
[RFC4553] RFC4553 (2006-06), Structure-Agnostic Time Division Multiplexing
(TDM) over Packet (SAToP)
[RFC4618] RFC4618 (2006-9), Encapsulation Methods for Transport of
PPP/High-Level Data Link Control (HDLC) over MPLS Networks
[RFC4717] RFC4717 (2006-12), Encapsulation Methods for Transport of
Asynchronous Transfer Mode (ATM) over MPLS Networks
[RFC 5086] RFC 5086 (2007–12), Structure-aware TDM Circuit Emulation
Service over Packet Switched Network (CESoPSN)
[T1.102] T1.102 (1993), Digital hierarchy - Electrical interfaces
[T1.107] T1.107 (1995), Digital Hierarchy - Formats Specifications. It defines
the Northern American plesiochronous digital hierarchy and framing
types (DS0, DS1, DS1C, DS2, DS3 DS4NA) including super frame
end extended super frame formats for DS1.
[T1.231] T1.231 (2003), Layer 1 in-service transmission performance
monitoring. It defines basic performance monitoring frame work for
Northern American plesiochronous digital hierarchy like anomalies,
defects, failures, PM primitives
[T1.231.02] T1.231.02 (2003), Layer 1 in-service transmission - Performance
monitoring. It defines the DS1 defect detection, failure filtering and
performance monitoring parameters
[T1.231.03] T1.231.03 (2003), Layer 1 in-service transmission performance
monitoring. It defines defects, alarms and basic performance
monitoring framework for Northern American PDH interfaces. The
03 document is specific for DS3.
[T1.231.04] T1.231.04 (2003), SONET layer 1 inservice digital transmission
performance monitoring

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

69
References

Reference Description
[T1.403] T1.403 (1999), Network and customer Installation interfaces - DS1
electrical interface. It defines the electrical characteristics of the
physical DS1 signal, connectors and additionally the DS1 framing
format
[UNI3.1] ATM Forum AF-UNI-0010_002 ATM User-Network Interface
Specification Version 3.1

Tellabs ® 8600 Managed Edge System 76.8611-40067A


Tellabs ® 8607 Access Switch FP1.1 Reference Manual © 2010 Tellabs.

70
End of Life Treatment

End of Life Treatment


Disposal of electrical and electronic waste in member states of the European Union shall be done
according to Directive 2002/96/EC Waste of Electrical and Electronic Equipment (WEEE) and
local legislation.

Do not dispose electrical and electronic equipment with unsorted municipal and household waste.
Please consult your local authorities for suitable disposal method for electronic and electrical waste.

Correct handling of the disposed equipment contributes to reuse, recycling and other form of
recovery to protect the environment.

The equipment is marked with the figure shown below, to indicate that the equipment must be
collected separately.

76.8611-40067A Tellabs ® 8600 Managed Edge System


© 2010 Tellabs. Tellabs ® 8607 Access Switch FP1.1 Reference Manual

71

You might also like