Cairo Festival City

Oriana Phase One


Addendum No. 1

Gate Entry Roundabout Landscape

Tender Package

Bill of Quantities
Item Qty Unit

HARDSCAPE
The following works are to be carried out in accordance with the Technical
Specifications & Drawings for Landscaping Works prepared

Plain Concrete
Supply, place, finish, cure and test of plain cast- in-place concrete, with
specified cement Grade 200, as per drawings and in accordance with
specifications.

A Formed plain concrete sloped wall, natural grey color, sand blasted finish with 119 m²
expansion joints each 3m and control saw-cut joints.

Interlocking Concrete
Supply and install precast concrete interlock pavers 80mm thick, w/300kg/cm2
strength with shape and pattern as per drawings on 50mm thick cement
mortar bed, 100 mm thick crushed aggregate stone base course set non-
woven geotextile protective membrane (200 gm/m2), wrap over end of sand
bedding, set on compacted soil; including edge beams, levelling of the sub-
grade layer and all necessary tests, all according to the drawings and
specifications prepared

B Interlock Concrete pavers, Color: Grey, running bond pattern, Size: 200 x 100 147 m²
x 80mm

C Interlock Concrete pavers, Color: Reddish, 200mm wide header course 368 m
pattern, Size: 200 x 100 x 80mm

Stone
Supply and install Abbasia cobble igneous stone on rich 40mm thick mortar
bed including all necessary requirements, all according to the drawings and
specifications prepared

D 200x200x60mm avg. thick Abbasia cobble igneous stone; with split face finish 283 m²

Supply and install black basalt cobble stone on rich 40mm thick mortar bed,
200mm thick crushed aggregate stone base course including all necessary
requirements, all according to the drawings and specifications prepared

E 200x200x60mm avg. thick black basalt cobble stone; with rough finish 1,117 m²

Supply and install red Hurghada granite cobble stone including all necessary
requirements, all according to the drawings and specifications prepared

F 100x100x40mm thick. red Hurghada granite cobble stone band @ 400mm. 128 m²
width; with split face finish

G 100x100x40mm thick. red Hurghada granite cobble stone band @ 200mm. 21 m²


width; with split face finish

Total Page 01 carried forward to collection


Granite Pavers
Supply and install Local grey granite pavers on rich 40mm thick mortar bed
including all necessary requirements, all according to the drawings and
specifications prepared

A 200x200x60mm. thick, Local grey granite pavers, w/semi rough finish 644 m²

Curbs
B 150x500x300mm precast concrete curb 121 m

Loose Pebbles
Supply and install 100mm thick layer of Loose pebbles, with 30-50mm. dia.
Set on Compacted subgrade including all necessary requirements, all
according to the drawings and specifications prepared

C 100mm thick layer of Loose pebbles, with 30-50mm. dia. Size, White Color 245 m²

Polyethylene Sheets

D Polyethylene sheets (400 micron thick) under slab on grade and foots. 283 m²

Geotextile Sheets

E Non-woven geotextile protective membrane (200 gm/m2) under interlock 221 m²

Total Page 02 carried forward to collection


Collection

Page 1

Page 2
Total Hardscape Carried forward to Summary
Item Qty Unit

IRRIGATION
The following works are to be carried out in accordance with the Technical
Specifications for Irrigation Works prepared and the Package Drawings listed
below: -

Pipes

Irrigation Pipes
supply and install HDPE pipes of 10 bar working pressure including
earthwork, trenchwork, backfilling, bedding, all fittings, joints, bends, special
fittings, welding, testing and disinfection and any other necessary
requirements, all according to the drawings and specifications prepared

A 110 mm irrigation pipe diameter 41 m

B 90 mm irrigation pipe diameter 60 m

C 75 mm irrigation pipe diameter 2 m

D 63 mm irrigation pipe diameter 84 m

E 50 mm irrigation pipe diameter 110 m

F 32 mm irrigation pipe diameter 681 m

Valves

Directly Buried Gate Valve


Supply and install directly buried gate valve including excavation, valve box
with cover, waterproof connectors, pressure regulator, brass ball valve, male
adapter, brick support, PVC elbow, PVC tee, Nipple, washed gravel and any
other necessary requirements, all according to the drawings and
specifications prepared
G Gate valve 110mm ( 4") 1 nr

Quick coupling valve


Supply and install Quick Coupling valve including excavation. valve box, PVC
nipple, PVC street elbows, brick support, PVC tee or PE saddle and any other
necessary requirements, all according to the drawings and specifications
prepared

H Quick Coupling Valve 1" 3 nr

Remote Control Solenoid Valves


Supply and install solenoid valve including excavation, valve box with cover,
waterproof connectors, pressure regulator, ball valve, male adapter, brick
support, PVC elbow, PVC tee, Nipple, washed gravel and any other
necessary requirements, all according to the drawings and specifications
prepared

I Solenoid valves 1" 2 nr

J Solenoid valves 1.5" 4 nr


Total Page 01 carried forward to collection
Y-Screen filters
Supply, install and test Y-screen filters including all required fittings and
accessories as per specification and drawings

A Y-screen filter 1" 1 nr

B Y-screen filter 1.5" 2 nr


Total Page 02 carried forward to collection
Collection

Page 1

Page 2
Total Irrigation Carried forward to Summary
Rate Total (EGP) Rate Total (EGP)

230.30 9,442.30 Err:509 Err:509

228.42 13,750.88 Err:509 Err:509

197.40 394.80 Err:509 Err:509

183.30 15,397.20 Err:509 Err:509

145.70 16,027.00 Err:509 Err:509

76.14 51,851.34 Err:509 Err:509

12,000.00 12,000.00 Err:509 Err:509

4,115.00 12,345.00 Err:509 Err:509

3,350.00 6,700.00 Err:509 Err:509

3,751.00 15,004.00 Err:509 Err:509


152,912.52 Err:509
6,450.00 6,450.00 Err:509 Err:509
.
7,690.00 15,380.00 Err:509 Err:509
21830 Err:509
152,912.52 Err:509

21830 Err:509
174742.524 Err:509
Item Qty Unit

SOFTSCAPE IRRIGATION
The following works are to be carried out in accordance with the Technical
Specifications for Landscaping Works prepared and the Package Drawings
listed below: -

Drip Line Pipes


Supply, install and test PE inline pipes including all required fittings and
accessories as per specification and drawings

A Drip line pipes for groundcovers 3927 m

Bubblers
Supply and install Pressure Compensating Bubbler including XF pop-up body,
swing joint, PVC tee or PE saddle and any other necessary requirements, all
according to the drawings and specifications prepared

B Bubbler with flow 110 LIT/HR at 1 Bar 33 nr

Sprinklers
Supply and install sprinkler including XF pop-up body, swing joint, PVC tee or
PE saddle and any other necessary requirements, all according to the
drawings and specifications prepared
C Sprayer with full circular watering pattern (360°) 8 nr

D Sprayer with half circular watering pattern (180°) 35 nr

E Sprayer with one quarter circular watering pattern (90°) 12 nr

Reinforce Rubber Hose


Supply, install and test reinforced rubber hose including all required fittings
and accessories as per specification and drawings
F Reinforced Rubber Hose 1" with minimum length 30m 3 nr

Total Page 01 carried forward to collection


Collection

Page 1
Total Hardscape Carried forward to Summary
Item Qty Unit

LANSCAPE LIGHTING
The following works are to be supplied, installed, tested and commissioned in
accordance with the Technical Specifications & Drawings for Lanscape
Lighting Works prepared

Low Voltage Distribution Panels


Supply, install and connect Low Voltage Distribution Panels including
cabinets, fuses, circuit breakers, busbars, photo cell, connectors, spares,
spaces, earthing accessories, concrete footings and any other necessary
requirements, all according to the drawings and specifcations prepared

A LP-LS 1 nr

Low Voltage Distribution Panels Cables


Supply, install and connect low voltage cables including trench excavation,
roadcrossing, warming tape, cable glands, connectors, sand bedding, back
filling, compating and any other necessary requirements, all according to the
drawings and specifcations prepared

B (4x16)+16 sqmm AL/PVC/STA/PVC to the nearest power source 1 item


Landscape Lighting Wiring
Supply, install and connect wiring from lighting to lighting panels including trial
holes, earth pit per hole, trench excavation, earthwork support, concrete bed if
required, warming tape, cable glands, connectors, sand bedding, back filling,
compacting, UPVC conduits and any other necessary requirements, all
according to the drawings and specifcations prepared

C (3 x 4)mm2 CU/PVC/STA/PVC cable 1,037 m

Landscape Lighting Outlets


Supply, install and connect outlets for landscape lighting fixtures including
installation of fixture (supplied by the Client), conduits, boxes home run to the
panel, grounding accessories, concrete footings and any other necessary
requirements, all according to the drawings and specifcations prepared

D Lighting Outlet 87 nr
Total Page 01 carried forward to collection
Collection

Page 1
Total Lighting Carried forward to Summary
Item Qty Unit

SIGNAGE
The following works are to be carried out in accordance with the Technical
Specifications and Drawings for Signage Works prepared

Signage
Supply and install 300mm width cement blockwork wall with 2.70m height
from above finish with 800x800x100 local travertine copping, (150x150 to
300x300mm) local beige cladding 40mm thick, and (50x50mm) mosaic tiles
cladding 500mm thick, set on 250 mm thick. reinforced to concrete base, set
on 100mm thick. plain concrete, set on compacted subgrade, including all
fixation, finishes and all structure works, all according to the drawings and
specifications prepared

A Signage wall 2.70m height. Typ. (W-01) 12 m


Total Page 01 carried forward to collection
Collection

Page 1
Total Signage Carried forward to Summary