Analysis values = M (M)anual, (L)eft, Position (X) from analysis, (R)ight, (C)ritical
Major bending (Mx*) = 4.0 kNm Major bending (Mx*) = 4.00 kNm
Minor bending (My*) = 0.0 kNm Minor bending (My*) = 0.00 kNm
Shear Force (V*) = 2.0 kN Shear Force (V*) = 2.00 kN
Duration (k1) = 0.80 Compression (Nc*) = 0.00 kN
Long term LL factor (Ψl) = 0.60 Tension (Nt*) = 0.00 kN
Stiffness (Ix) = 51.8 x10⁶ mm⁴ Duration factor (j2) = 2.0 Ψs = 0.00
Instantaneous δDL = 0.0 mm at 0mm from LHS Span / -
δLL = 0.0 mm at 0mm from LHS Span / -
δDL = j2*(δDL+Ψl.δLL) = 0.0 mm Span / -
δDL+Ψs.δLL = j2*(δDL+Ψl.δLL) + Ψs.δLL = 0.0 mm Span / -
Deflection limits
Importance:
Category 1 House failure affecting < 25m², secondary building element
Category 2 Building, house failure affecting > 25m²
Category 3 Important
k4 factor:
Partial seasoning factor
Refer Cl 2.4.2.2 & 2.4.2.3 for more information.
k6 factor:
Refer Cl 2.4.3 if designing structures near coastal
regions of Queensland north of 25°S and all other
regions north of 16°S
Material constant:
Refer to Appendix E2
Bending ratio = 0.25
Compression ratio = 0.25
Duration:
Storage and passage durations used
are based on intermediate durations from Table 2.3
and used with engineering judgement.
δPLLmax.imm/δLLTotal.imm:
Long term proportion of live load considered
for dead load deflections is affected
by whether it is a point load or a UDL (refer
to AS1170.2 Table 4.1)
Compression/Bending:
Refer 3.5(1) & 3.5(2)
Tension/Bending:
Refer 3.5(3) & 3.5(4)
Service class:
Service class defined in AS/NZS 1328.1 1998 Glued Laminated Structural Timber
1 - Domestic houses, Commerical Offices
2 - Open sheds, exposed beams under soffits, porches, laundries
3 - Marine structures, Bridges
S - Severe/Adverse requires specialist advice