You are on page 1of 36

Pricelist

Applied
Systems

Prices and technical information for Applied Systems 2015-2016

AS_RS&MNE.indd 1 30.4.2015 г. 15:11:53 ч.


Table of contents
Type Refrigerant Compressor Material Capacity Page
Air cooled chiller Inverter R-410A Swing EWAQ-A 5-13 kW 3
Air cooled heat pump Inverter R-410A Swing EWYQ-A 5-13 kW 4
Air cooled chiller Inverter R-410A Scroll EWAQ-BAW 17-75 kW 5
Air cooled heat pump Inverter R-410A Scroll EWYQ-BAW 17-75 kW 5
Air cooled heat pump Inverter - split version R-410A Srcoll SEHVX - AAW + SERHQ-AAW1 20-63 kW 6
Water cooled chiller R-407C Scroll EWWP-KBW1N 13-65 kW 7
Water cooled chiller R-407C Scroll EWWP-KAW1M 86-194 kW 8
Condenserless chiller R-407C Scroll EWLP-KBW1N 12-62 kW 9
Condensing unit heat pump Inverter R-410A Scroll ERQ 11-28 kW 10
Hydronic Kit EKBT / EHMC 11
Rooftop heat pump R-410A Scroll UATYQ-CY1 27-73 kW 11
Rooftop heat pump R-407C Scroll UATYP-AY1 79-110 kW 11
Fan coil
Low ESP duct FWE-C 2,1 - 10 kW 12
Medium ESP duct FWB-B 2,6 - 11 kW 13
Medium ESP duct / BLDC FWP-A 2,6 – 6,5 kW 14
High ESP flexi duct FWD-A 3,9 - 18 kW 15
Cassette 600x600 FWF-C 2,5 - 4,5 kW 16
Cassette 600x600 FWF-B 1,7 - 4 kW 16
Cassette 900x900 FWC-B 5 - 7,2 kW 16
Cassette 900×900 FWG- A 5,9-11,75 kW 17
Wall mounted FWT-C 2,3 - 5,3 kW 17
Floor standing FWV-D 1,5 - 8 kW 19
Flexi type FWL-D 1,5 - 8 kW 20
Flexi concealed FWM-D 1,5 - 8 kW 21
Floor standing / BLDC FWZ-A 2,6 - 10 kW 23
Flexi type / BLDC FWR-A 2,6 - 10 kW 24
Flexi concealed / BLDC FWS-A 2,6 - 10 kW 25
Air Handling Units - AHU D-AHU Modular 1200-15000 m3/h 27
Overview: Air cooled chiller portfolio 28
Overview: Portfolio Water cooled and Condenserless units 30
Large Chillers options and accessories summary 30
Air Cooler 32
Air Handling Unit 32
Dry Cooler & Condenser 32
Cooling Tower 32
Compressor Service Screw/Recip 32
Measuring conditions 33
Commercial terms and conditions 35

NOTE:
All prices are list prices, incl. VAT and valid from 1. April 2015 till 31. March 2016.
All prior pricelists are not valid anymore. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com/legal-notice.jsp).
We reserve the right for printing errors and model changes. The LOT1&2 regulation requires the manufacturers to publish additional energy efficiency data
for some products shown in this literature. From September 2015, these required efficiency data can be publicly viewed and downloaded from the following
free access website: www.daikin.at/energylabel/Lot1_2

AS_RS&MNE.indd 2 30.4.2015 г. 15:11:53 ч.


EWAQ-A

EWAQ-A
Air cooled chiller inverter
High ESEER thanks to inverter technology, integrated hydronics.

Unit size (1 phase) EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP


Price € 3.523,- 3.859,- 4.279,-
Cooling capacity kW 5,2 6 7,1
EER 2,75 2,55 2,41
ESEER 3,75 3,83 3,87
Sound power level dB(A) 62 62 63

Options
OP10 evaporator heater tape € 487,- 487,- 487,-

Unit size (1 phase) EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P


Price € 4.883,- 5.170,- 5.552,-
Cooling capacity kW 8,6 9,6 11,1
EER 3,05 2,93 2,85
ESEER 4,31 4,3 4,33
Sound power level dB(A) 64 64 64

Options
OP10 evaporator heater tape € 541,- 541,- 541,-
SOPHP high ESP pump (up to 90 kPa) € on request on request on request
EKRP1HBA digital I/0 PCB € 152,- 152,- 152,-

Unit size (3 phase) EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P


Price € 5.092,- 5.600,- 5.935,-
Cooling capacity kW 9,1 11,1 13,3
EER 2,99 2,85 2,57
ESEER 4,43 4,44 4,36
Sound power level dB(A) 64 64 66

Options
OP10 evaporator heater tape € 541,- 541,- 541,-
SOPHP high ESP pump (up to 90 kPa) € on request on request on request
EKRP1HBA digital I/0 PCB € 152,- 152,- 152,-

Applied Systems Price list 2015-20163

AS_RS&MNE.indd 3 30.4.2015 г. 15:11:54 ч.


EWYQ-A

EWYQ-A
Air cooled heat pump inverter

Wide operation range - ambient temperature in heating down to


-15°C.

Unit size (1 phase) EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP


Price € 4.068,- 4.394,- 4.694,-
Cooling capacity kW 5,2 6 7,1
EER 2,75 2,55 2,41
Heating capacity kW 5,65 6,35 7,75
COP 2,87 2,83 2,74
Sound power level dB(A) 62 62 63

Options
OP10 evaporator heater tape € 487,- 487,- 487,-

Unit size (1 phase) EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P


Price € 5.621,- 5.916,- 6.271,-
Cooling capacity kW 8,6 9,6 11,1
EER 3,05 2,93 2,85
ESEER 4,31 4,3 4,33
Heating capacity kW 9,9 11,4 12,9
COP 3,3 3,29 3,27
Sound power level dB(A) 64 64 64

Options
OP10 evaporator heater tape € 541,- 541,- 541,-
SOPHP high ESP pump (up to 90 kPa) € on request on request on request
EKRP1HBA digital I/0 PCB € 152,- 152,- 152,-

Unit size (3 phase) EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P


Price € 5.840,- 6.339,- 6.701,-
Cooling capacity kW 9,1 11,1 13,3
EER 2,99 2,85 2,57
ESEER 4,43 4,44 4,36
Heating capacity kW 10,9 12,4 13,9
COP 3,28 3,27 3,25
Sound power level dB(A) 64 64 66

Options
OP10 evaporator heater tape € 541,- 541,- 541,-
SOPHP high ESP pump (up to 90 kPa) € on request on request on request
EKRP1HBA digital I/0 PCB € 152,- 152,- 152,-

AS_RS&MNE.indd 4 30.4.2015 г. 15:11:54 ч.


EWAQ-BAW, EWYQ-BAW

EWAQ-BAW
Air cooled chiller inverter

High efficiency with leader-of-class ESEER.


No buffer tank required for standard applications.

Unit size EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW EWAQ050BAW EWAQ064BAW


Price € 8.445,- 9.943,- 11.215,- 12.937,- 17.118,- 19.069,- 22.020,-
Cooling capacity (nominal) EWAQ - BAWN / BAWP kW 17,4 / 16,6 21,7 / 20,7 25,8 / 24,7 32,3 / 30,9 43,4 / 41,5 51,8 / 49,7 64,5 / 62,3
ESEER EWAQ - BAWN / BAWP 4,33 / 4,21 4,08 / 4,18 3,85 / 4,04 3,39 / 3,62 4,19 / 4,24 3,96 / 4,12 3,64 / 3,78
Sound power level dB(A) 78 78 78 80 81 81 83

Options
OP10 Evaporator electric heater € 632,- 632,- 632,- 632,- 741,- 741,- 741,-
OPSP One centrifugal pump (low lift) € 702,- 702,- 702,- 857,- 857,- 857,- 857,-
OPHP One centrifugal pump (high lift) € 1.032,- 1.032,- 1.032,- 1.032,- 1.258,- 1.258,- 1.258,-
Low leaving water operation down to
OPZL € 469,- 469,- 469,- 469,- 572,- 572,- 572,-
-10 °C

Kit
Demand PCB Remote:
EKRP1AHT € 151,- 151,- 151,- 151,- 302,- 302,- 302,-
On/Off, Cool/heat, thermo On/Off
EKRUAHT Additional remote user interface € 226,- 226,- 226,- 226,- 226,- 226,- 226,-
BHGP26A1 Digital pressure gauges € 496,- 496,- 496,- 496,- 992,- 992,- 992,-
External adaptor for:
DTA104A62 € 461,- 461,- 461,- 461,- 922,- 922,- 922,-
Demand and Low noise control
RTD-W Modbus interface € 364,- 364,- 364,- 364,- 364,- 364,- 364,-

EWYQ-BAW
Air cooled heat pump Inverter

Wide operation range - ambient temperature in heating down to


-15°C.

Unit size EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW EWYQ050BAW EWYQ064BAW


Price € 9.713,- 11.437,- 12.899,- 14.882,- 19.685,- 21.929,- 25.324,-
Cooling capacity (nominal)
kW 17,4 / 16,6 21,7 / 20,7 25,8 / 24,7 32,3 / 30,9 43,4 / 41,5 51,8 / 49,7 64,5 / 62,3
EWYQ - BAWN / BAWP
ESEER EWYQ - BAWN / BAWP 4,33 / 4,21 4,08 / 4,18 3,85 / 4,04 3,39 / 3,62 4,19 / 4,24 3,96 / 4,12 3,64 / 3,78
Heating capacity (nominal)
kW 16,2 / 17,0 20,3 / 21,3 24,6 / 25,7 30,7 / 32,1 41,6 / 42,5 49,0 / 51,1 61,5 / 63,7
EWYQ - BAWN / BAWP
COP EWYQ - BAWN / BAWP 2,93 / 2,97 2,86 / 2,86 2,76 / 2,75 2,90 / 2,89 2,90 / 2,89 2,78 / 2,76 2,97 / 2,94
Sound power level dB(A) 78 78 80 80 81 83 83

Options
OP10 Evaporator electric heater € 632,- 632,- 632,- 632,- 741,- 741,- 741,-
OPSP One centrifugal pump (low lift) € 702,- 702,- 702,- 857,- 857,- 857,- 857,-
OPHP One centrifugal pump (high lift) € 1.032,- 1.032,- 1.032,- 1.032,- 1.258,- 1.258,- 1.258,-
Low leaving water operation down to
OPZL € 469,- 469,- 469,- 469,- 572,- 572,- 572,-
-10 °C

Kit
Demand PCB Remote:
EKRP1AHT € 151,- 151,- 151,- 151,- 302,- 302,- 302,-
On/Off, Cool/heat, thermo On/Off
EKRUAHT Additional remote user interface € 226,- 226,- 226,- 226,- 226,- 226,- 226,-
BHGP26A1 Digital pressure gauges € 496,- 496,- 496,- 496,- 992,- 992,- 992,-
External adaptor for:
DTA104A62 € 461,- 461,- 461,- 461,- 922,- 922,- 922,-
Demand and Low noise control
RTD-W Modbus interface € 364,- 364,- 364,- 364,- 364,- 364,- 364,-

Applied Systems Price list 2015-20165

AS_RS&MNE.indd 5 30.4.2015 г. 15:11:55 ч.


SEHVX-AAW, SERHQ-AAW1

SEHVX - AAW
Air cooled heat pump inverter - split version

Unit size 20 32 40 64
Indoor unit 1× SEHVX20AAW 1× SEHVX32AAW 1× SEHVX40AAW 1× SEHVX64AAW
Outdoor Units 1× SERHQ020AAW1 1× SERHQ032AAW1 2× SERHQ020AAW1 2× SERHQ032AAW1
Refnet type - - KHRQ22M64T8 KHRQ22M75T8
Indoor unit Price per each € 4.995,- 5.582,- 5.854,- 5.960,-
Outdoor unit Price per each € 7.322,- 10.316,- 7.322,- 10.316,-
Refnet Price per each - - 163,- 199,-
Unit Price per each (indoor + outdoor(s) + refnet) € 12.317,- 15.898,- 20.661,- 26.791,-
Cooling Capacity (nominal) kW 20,7 (1) 30,9 (1) 41,5 (1) 62,3 (1)
Cooling Capacity (maximum) 24,7 (1) 36,9 (1) 49,5 (1) 74,3 (1)
EER dB(A) 2,73 (1) 2,29 (1) 2,69 (1) 2,27 (1)
Heating Capacity (nominal) kW 21,3 (2)(3) 32,2 (2)(3) 42,5 (2)(3) 63,7 (2)(3)
Heating Capacity (maximum) kW 25,3 (2)(3) 38,1 (2)(3) 50,5 (2)(3) 75,7 (2)(3)
COP 3,48 (2) / 2,86 (3) 3,68 (2) / 2,89 (3) 3,54 (2) / 2,89 (3) 3,77 (2) / 2,94 (3)
Sound power level (outdoor unit / each) dB(A) 78 dB(A) 80 dB(A) 78 dB(A) 80 dB(A)
Indoor unit connection (liquid / gas) 12,7 / 25,4 12,7 / 25,4 15,9 / 31,8 15,9 / 31,8

Standard Options SEHVX20AAW SEHVX32AAW SEHVX40AAW SEHVX64AAW


Standard Hydraulic package
€ including as standard including as standard including as standard including as standard
One centrifugal pump

Kit SEHVX20AAW SEHVX32AAW SEHVX40AAW SEHVX64AAW


Demand PCB Remote:
EKRP1AHT € 151,- 151,- 302,- 302,-
On/Off, Cool/heat, thermo On/Off
External adaptor for:
DTA104A62 € 461,- 461,- 922,- 922,-
Demand and Low noise control
RTD-W Modbus interface € 364,- 364,- 364,- 364,-
EKCC*-W Cascade Control € 1.237,- 1.237,- 1.237,- 1.237,-

Notes:
(1) Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011
(2) Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011
(3) Heating Ta DB/WB 7/6°C - LWC45°C

AS_RS&MNE.indd 6 30.4.2015 г. 15:11:56 ч.


EWWP-KBW1N

EWWP-KBW1N
Water cooled chiller

Unit size EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N


Price € 4.607,- 6.238,- 6.930,- 7.673,-
Cooling capacity kW 12,9 21,4 27,8 32,3
EER 3,44 3,49 3,54 3,54
Heat rejection capacity kW 16,7 27,5 35,6 41,5
Sound power level dB(A) 64 64 64 71

Options
OPZH glycol application to -5 °C LWE € 295,- 295,- 295,- 295,-
OPZL glycol application to -10 °C LWE € 295,- 295,- 295,- 295,-

Kit
EKLS1 low noise kit 5 HP € 234,- – – –
EKLS2 low noise kit 8/10/12 HP € – 234,- 234,- 234,-
EKAC10C BMS address card € 176,- 176,- 176,- 176,-
EKRUMCA remote user interface € 233,- 233,- 233,- 233,-
EHMC10A10 hydraulic module € 2.694,- 2.694,- 2.694,- –
EHMC10A80 hydraulic module – pump size up € 2.767,- 2.767,- 2.767,- –
EHMC15A10 hydraulic module € – – 2.865,- 2.865,-
EHMC15A80 hydraulic module – pump size up € – – 2.939,- 2.939,-

Unit size EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N


Price € 9.492,- 11.248,- 13.504,-
Cooling capacity kW 42,8 55,7 64,7
EER 3,51 3,48 3,55
Heat rejection capacity kW 55,0 71,7 83
Sound power level dB(A) 67 67 74

Options
OPZH glycol application to -5 °C LWE € 295,- 295,- 295,-
OPZL glycol application to -10 °C LWE € 295,- 295,- 295,-

Kit
EKLS2 low noise kit 8/10/12 HP (2 pcs.) € 468,- 468,- 468,-
EKAC10C BMS address card € 176,- 176,- 176,-
EKRUMCA remote user interface € 233,- 233,- 233,-
EHMC15A10 hydraulic module € 2.865,- – –
EHMC15A80 hydraulic module – pump size up € 2.939,- – –
EHMC30A10 hydraulic module € 3.050,- 3.050,- 3.050,-
EHMC30A80 hydraulic module – pump size up € 3.148,- 3.148,- 3.148,-

Note: E 23KAC10C is needed for direct BMS connection via Modbus


EKAC10C is needed to install EKRUMCA

Applied Systems Price list 2015-20167

AS_RS&MNE.indd 7 30.4.2015 г. 15:11:56 ч.


EWWP-KAW1M

EWWP-KAW1M
Water cooled chiller

Capacity index 090 100 110 120


EWWP045KAW1M EWWP045KAW1M EWWP055KAW1M EWWP055KAW1M
Basic model
EWWP045KAW1M EWWP055KAW1M EWWP055KAW1M EWWP065KAW1M
Control box ECB2MUW ECB2MUW ECB2MUW ECB2MUW
Price € 19.990,- 22.499,- 25.012,- 27.839,-
Cooling capacity kW 85,7 98,6 112 121
Sound power level dB(A) 71 71 71 75

Options
OPZH glycol application to -5°C LWE € 590,- 590,- 590,- 590,-
OPZL glycol application to -10°C LWE € 590,- 590,- 590,- 590,-

Capacity index 130 145 155 165


EWWP045KAW1M EWWP045KAW1M EWWP055KAW1M
EWWP065KAW1M
Basic model EWWP045KAW1M EWWP055KAW1M EWWP055KAW1M
EWWP065KAW1M
EWWP055KAW1M EWWP055KAW1M EWWP055KAW1M
Control box ECB2MUW ECB3MUW ECB3MUW ECB3MUW
Price € 30.668,- 30.777,- 33.290,- 35.801,-
Cooling capacity kW 130 141 154 167
Sound power level dB(A) 77 73 73 73

Options
OPZH glycol application to -5°C LWE € 590,- 885,- 885,- 885,-
OPZL glycol application to -10°C LWE € 590,- 885,- 885,- 885,-

Capacity index 175 185 195


EWWP055KAW1M EWWP055KAW1M EWWP065KAW1M
Basic model EWWP055KAW1M EWWP065KAW1M EWWP065KAW1M
EWWP065KAW1M EWWP065KAW1M EWWP065KAW1M
Control box ECB3MUW ECB3MUW ECB3MUW
Price € 38.628,- 41.457,- 44.284,-
Cooling capacity kW 176 185 194
Sound power level dB(A) 76 78 79

Options
OPZH glycol application to -5°C LWE € 885,- 885,- 885,-
OPZL glycol application to -10°C LWE € 885,- 885,- 885,-

AS_RS&MNE.indd 8 30.4.2015 г. 15:11:57 ч.


EWLP-KBW1N

EWLP-KBW1N
Condenserless chiller

Unit size EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N


Price € 4.134,- 5.135,- 5.870,- 7.027,-
Cooling capacity kW 12,1 20 26,8 31,2
EER 2,88 3,03 3,15 3,09
Sound power level dB(A) 64 64 64 71

Options
OPZH glycol application to -5°C LWE € 295,- 295,- 295,- 295,-
OPZL glycol application to -10°C LWE € 295,- 295,- 295,- 295,-

Kit
EKLS1 low noise kit 5 HP € 234,- – – –
EKLS2 low noise kit 8/10/12 HP € – 234,- 234,- 234,-
EKAC10C BMS address card € 176,- 176,- 176,- 176,-
EKRUMCA remote user interface € 233,- 233,- 233,- 233,-
EHMC10A10 hydraulic module € 2.694,- 2.694,- 2.694,- –
EHMC10A80 hydraulic module – pump size up € 2.767,- 2.767,- 2.767,- –
EHMC15A10 hydraulic module € – – 2.865,- 2.865,-
EHMC15A80 hydraulic module – pump size up € – – 2.939,- 2.939,-

Unit size EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N


Price € 8.830,- 9.451,- 10.682,-
Cooling capacity kW 40 53,7 62,4
EER 2,99 3,02 3,07
Sound power level dB(A) 67 67 74

Options
OPZH glycol application to -5°C LWE € 295,- 295,- 295,-
OPZL glycol application to -10°C LWE € 295,- 295,- 295,-

Kit
EKLS2 low noise kit 8/10/12 HP (2 pcs.) € 468,- 468,- 468,-
EKAC10C BMS address card € 176,- 176,- 176,-
EKRUMCA remote user interface € 233,- 233,- 233,-
EHMC15A10 hydraulic module € 2.865,- – –
EHMC15A80 hydraulic module – pump size up € 2.939,- – –
EHMC30A10 hydraulic module € 3.050,- 3.050,- 3.050,-
EHMC30A80 hydraulic module – pump size up € 3.148,- 3.148,- 3.148,-

Note: E KAC10C is needed for direct BMS connection via Modbus


EKAC10C is needed to install EKRUMCA

Applied Systems Price list 2015-20169

AS_RS&MNE.indd 9 30.4.2015 г. 15:11:58 ч.


Outdoor units

ERQ Inverter heat pump


condensing units
ERQ-A

High efficiency inverter heat pump outdoor units for connection


to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air
Curtains

Type for 1~ 230V power supply ERQ100AV1 ERQ125AV1 ERQ140AV1


Capacity index 100 125 140
Nominal cooling capacity kW 11,2 14,0 15,5
Nominal heating capacity kW 12,5 16,0 18,0
Price € 3.460,- 4.325,- 4.845,-

Type for 3N~ 400V power supply ERQ125AW1 ERQ200AW1 ERQ250AW1


Capacity index 125 200 250
Nominal cooling capacity kW 14,0 22,4 28,0
Nominal heating capacity kW 16,0 25,0 31,5
Price € 3.765,- 6.007,- 7.005,-
Notes:
- When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain
- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K,
on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Control box EKEQDCB EKEQFCBA


Control type Daikin control Free (External) control
• (X-Control): 0~10V direct capacity control (5V = maintain
Room temperature control [via Remote Controller capacity, >5V colder air wanted, <5V warmer air wanted)
(accessory) or via External room temperature sensor • ( Y-Control): Fixed evaporation / condensation
Control options
(accessory)] temperature control
Return air temperature control (via a supplied thermistor) • ( W-Control): 0~10V linear capacity control (0V = 0%
capacity, 10V = 100% capacity
Price € 799,- 891,-
Notes:
- A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

Allowed heat exchanger capacity [kW] Combinable units


Expansion valve kit Price €
Minimum Maximum ERQ100- ERQ125- ERQ140- ERQ200- ERQ250-
EKEXV63 6,3 7,8 • • 173,-
EKEXV80 7,9 9,9 • • • 185,-
EKEXV100 10,0 12,3 • • • • 191,-
EKEXV125 12,4 15,4 • • • • • 205,-
EKEXV140 15,5 17,6 • • • • 210,-
EKEXV200 17,7 24,6 • • 227,-
EKEXV250 24,7 30,8 • • 242,-

Notes:
- An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains,
- The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger,
- The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors)
- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K, condenser sub-cool = 3K,
on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Unit-specific Accessories
EKEQDCB EKEQFCBA Price €
BRC1D52 Basic wired remote controller with weekly timer • • 92,-
BRC1E52B Standard wired remote controller with full-text interface and back-light • • 140,-
KRP4A51 Adaptor for external monitoring/control • 207,-
RTD-20 Adaptor for external monitoring/control with 0-10VDC linear capacity control • 418,-
KRCS01-1 External room temperature sensor • 82,-
KRC19-26 Mechanical cool/heat selector • • 50,-
KJB111A Fixing box for cool/heat selector • • 30,-

Notes:
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

10

AS_RS&MNE.indd 10 30.4.2015 г. 15:12:02 ч.


HYDRONIC KIT, ROOFTOP

HYDRONIC KIT

Buffer tanks
EKBT 200 l buffer tank with casing € 1.721,-
EKBT500N 500 l buffer tank € 2.164,-
EKBTC10N 1000 l buffer tank € 3.001,-
EKBT500C 500 l buffer tank with casing € 4.702,-
EKBTC10C 1000 l buffer tank with casing € 6.269,-

Hydraulic modules
EHMC10A10 hydraulic module € 2.694,-
EHMC10A80 hydraulic module – high ESP € 2.767,-
EHMC15A10 hydraulic module € 2.865,-
EHMC15A80 hydraulic module – high ESP € 2.939,-
EHMC30A10 hydraulic module € 3.050,-
EHMC30A80 hydraulic module – high ESP € 3.148,-

UATYQ-CY1
Rooftop heat pump

Convertible return and supply air: fan can be mounted in two


directions

Unit size UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1


Price € 6.990,- 10.146,- 13.118,- 15.608,- 16.188,- 16.246,-
Cooling capacity kW 27,34 35,58 44,72 55,69 66,82 72,6
EER 3,36 3,30 3,43 3,33 3,4 3,36
Heating capacity kW 24,91 34,79 41,79 53,93 61,69 69,61
COP 3,40 3,21 3,25 3,47 3,32 3,25
Sound power level dB(A) 82 83 83 87 90 90

Options
DEC101A51 € 1.052,- 1.052,- 1.052,- 1.052,- 1.052,- 1.052,-
DEC102A51 € 1.161,- 1.161,- 1.161,- 1.161,- 1.161,- 1.161,-
DTA103A51 € 512,- 512,- 512,- 512,- 512,- 512,-
ECONO250AY1 € 1.646,- – – – – –
ECONO350AY1 € – 1.729,- – – – –
ECONO450AY1 € – – 1.816,- – – –
ECONO550AY1 € – – – 1.906,- – –
ECONO600AY1 € – – – – 2.001,- –
ECONO700AY1 € – – – – – 2.102,-

UATYP-AY1
Rooftop heat pump

Belt driven fan enables air volume and static pressure to be


adjusted as required.

Unit size UATYP850AY1B UATYPC10AY1 UATYPC12AY1


Price € 19.174,- 23.816,- 27.302,-
Cooling capacity kW 78,60 101,10 109,60
EER 2,18 2,34 2,27
Heating capacity kW 87,80 102,30 126,30
COP 2,73 2,45 2,7
Sound pressure level at 1m dB(A) 74 80 80

Applied Systems Price list 2015-201611

AS_RS&MNE.indd 11 30.4.2015 г. 15:12:03 ч.


FWE-C, Low ESP duct fan coil

FWE-C
Fan coil, ACCESSORIES

4-speed fan motor, available static pressure up to 50Pa

Low ESP duct unit FWE-C 02 03 04 06 07 08 10


FWE**CT-, 2 pipe unit,
€ 242,- 273,- 297,- 386,- 415,- 489,- 588,-
standard, without valves
FWE**CTV, 2 pipe unit,
€ 398,- 429,- 454,- 539,- 568,- 634,- 729,-
with 3-ways 230V on/off valve, factory mounted
FWE**CTT, 2 pipe unit,
€ 326,- 357,- 378,- 467,- 493,- 562,- 657,-
with 2-ways 230V on/off valve, factory mounted
Cooling capacity (Total at Super High Speed) kW 2,17 3,22 4,34 6,06 6,83 7,84 9,96
Heating capacity (2-pipe at Super High Speed) kW 2,79 4,28 5,61 7,66 9,26 10,50 13,00
FWE**CF-, 4 pipe unit,
€ 283,- 318,- 347,- 446,- 475,- 557,- 657,-
standard, without valves
FWE**CFV, 4 pipe unit,
€ 564,- 601,- 626,- 721,- 750,- 828,- 925,-
with 3-ways 230V on/off valves, factory mounted
FWE**CFT, 4 pipe unit,
€ 458,- 493,- 520,- 615,- 644,- 721,- 818,-
with 2-ways 230V on/off valves, factory mounted
Cooling capacity (Total at Super High Speed) kW 2,10 3,16 3,98 6,05 6,76 7,79 9,91
Heating capacity (4-pipe at Super High Speed) (1) kW 2,30 3,53 4,56 6,17 7,60 8,52 10,40

Accessories for FWE-C 02 03 04 06 07 08 10


EK2MV3B10C5
2 pipes 3-ways on/off 230V valve kit
€ 105,-
EK2MV2B10C5
2 pipes 2-ways on/off 230V valve kit
€ 89,-
EK4MV3B10C5
4 pipes 3-ways on/off 230V valve kit
€ 200,-
EK4MV2B10C5
4 pipes 2-ways on/off 230V valve kit
€ 173,-

Controller for FWE-C 02 03 04 06 07 08 10


Controller electronic FWEC1A
Standard version, (see note 2) € 97,-
Controller electronic FWEC2A
Advanced version € 152,-
Controller electronic FWEC3A
Advanced Plus version € 208,-
Wall mounting kit (spacing collar) FWFCKA
for FWEC*A € 16,-
Temperature sensor kit FWTSKA
for FWEC*A € 8,-
Relative humidity sensor kit FWHSKA
for FWEC2A and FWEC3A € 23,-
EPIMSB6
Master / Slave interface
€ 159,-

Notes:
(1) Rating conditions: air 20°C DB, entering water 50°C, leaving water 40°C
(2) FWEC1A can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit

12

AS_RS&MNE.indd 12 30.4.2015 г. 15:12:05 ч.


FWB-B, Medium ESP duct fan coil

FWB-B
Fan coil, Accessories

Low sound power levels and electrical absorption thanks to plastic


impeller and improved electric motor.

Medium ESP duct unit FWB-B 02 03 04 05 06 07 08 09 10


FWB**BTN, 2 pipe unit,
€ 465,- 498,- 527,- 636,- 659,- 721,- 873,- 923,- 981,-
standard, without valves
FWB**BTV, 2 pipe unit,
€ 619,- 648,- 677,- 787,- 811,- 873,- 1.030,- 1.078,- 1.140,-
with 3-ways 230V on/off valve, factory mounted
FWB**BTNE, 2 pipe unit, without valves and
€ 752,- 785,- 814,- 956,- 979,- 1.039,- 1.210,- 1.260,- 1.320,-
electric heater, factory mounted
FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off
€ 902,- 933,- 964,- 1.105,- 1.129,- 1.187,- 1.371,- 1.417,- 1.479,-
valve and electric heater, factory mounted
Cooling capacity (Total at High Speed) kW 2,61 3,14 3,49 5,08 5,45 6,47 7,57 8,67 10,34
Heating capacity (2-pipe at High Speed) kW 5,47 6,01 6,47 10,31 11,39 12,28 15,05 16,85 18,78
Heating capacity (4-pipe at High Speed) kW 3,14 3,14 3,14 5,99 5,99 5,99 12,80 12,80 12,80

Accessories for FWB-B 02 03 04 05 06 07 08 09 10


Additional single row EAH04A6 EAH07A6 EAH10A6
heat exchanger € 183,- 205,- 269,-
E2MV307A6 E2MV310A6
3-way valve add. h/e
€ 194,- 194,-
E2MV207A6 E2MV210A6
2-way valve add. h/e
€ 100,- 105,-
YFSTA6
Fan stop thermostat
€ 18,-

Controller for FWB-B 02 03 04 05 06 07 08 09 10


Controller electronic FWEC1A
Standard version € 97,-
Controller electronic FWEC2A
Advanced version € 152,-
Controller electronic FWEC3A
Advanced Plus version € 208,-
Wall mounting kit (spacing collar) FWFCKA
for FWEC*A € 16,-
Temperature sensor kit FWTSKA
for FWEC*A € 8,-
Relative humidity sensor kit FWHSKA
for FWEC2A and FWEC3A € 23,-
EPIMSB6
Master / Slave interface
€ 159,-

Applied Systems Price list 2015-201613

AS_RS&MNE.indd 13 30.4.2015 г. 15:12:06 ч.


FWP - A, Medium ESP duct fan coil with DC fan motor

FWP-A
Fan coil, Accessories

Low sound level and up to 50% energy saving thanks to the BLDC
motor technology

Medium ESP duct unit with DC fan motor FWP-A 02 03 04 05 06 07


FWP**ATN, 2 pipe unit,
€ 636,- 663,- 688,- 807,- 818,- 873,-
standard, without valves
FWP**ATV, 2 pipe unit,
€ 776,- 805,- 832,- 952,- 960,- 1.016,-
with 3-ways 230V on/off valve, factory mounted
FWP**ATNE, 2 pipe unit, without valves and
€ 907,- 937,- 964,- 1.111,- 1.121,- 1.175,-
electric heater, factory mounted
FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off
€ 1.051,- 1.080,- 1.103,- 1.253,- 1.264,- 1.319,-
valve and electric heater, factory mounted
Cooling capacity (Total at High Speed) kW 2,61 3,14 3,49 5,08 5,45 6,47
Heating capacity (2-pipe at High Speed) kW 5,47 6,01 6,47 10,31 11,39 12,28
Heating capacity (4-pipe at High Speed) kW 3,14 3,14 3,14 5,99 5,99 5,99

Accessories for FWP-A 02 03 04 05 06 07


Additional single row EAH04A6 EAH07A6
heat exchanger € 183,- 205,-
E2MV307A6
3-way valve add. h/e
€ 194,-
E2MV207A6
2-way valve add. h/e
€ 100,-

Controller for FWP-A 02 03 04 05 06 07


Controller electronic FWEC3A
Advanced Plus version € 208,-
Wall mounting kit (spacing collar) FWFCKA
for FWEC*A € 16,-
Temperature sensor kit FWTSKA
for FWEC*A € 8,-
Relative humidity sensor kit FWHSKA
for FWEC2A and FWEC3A € 23,-

14

AS_RS&MNE.indd 14 30.4.2015 г. 15:12:07 ч.


FWD - A, High ESP flexi type fan coil

FWD - A
Fan coil, ACCESSORIES

Straight duct connector is mounted to discharge side

2-pipe unit FWD**AT 04 06 08 10 12 16 18


Price € 560,- 739,- 863,- 962,- 1.194,- 1.534,- 1.687,-
Cooling capacity (Total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30
Heating capacity (2-pipe at High Speed) kW 4,05 7,71 9,43 10,79 14,45 19,81 21,92

4-pipe unit FWD**AF 04 06 08 10 12 16 18


Price € 657,- 859,- 1.002,- 1.113,- 1.402,- 1.776,- 1.947,-
Cooling capacity (Total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30
Heating capacity (4-pipe at High Speed) kW 4,49 6,62 9,21 9,21 15,86 21,15 21,15

Accessories for FWD 04 06 08 10 12 16 18


Electric heater EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6
low capacity € 289,- 543,- 543,- 554,- 623,-
Electric heater EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6
high capacity € 289,- 543,- 543,- 554,- 623,-
ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6
2-pipe 3-way valve
€ 205,- 215,- 196,- 225,-
ED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6
4-pipe 3-way valve
€ 392,- 416,- 392,- 450,-
EDDPV10A6 EDDPV18A6
Vertical drainpan
€ 11,- 18,-
EDDPH10A6 EDDPH18A6
Horizontal drainpan
€ 17,- 23,-
YFSTA6
Fan stop thermostat
€ 18,-
EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6
Fresh air intake
€ 983,- 1.005,- 1.024,- 1.085,- 1.100,-

Controller for FWD 04 06 08 10 12 16 18


FWEC1A
Controller electronic FWEC1A
EPIB6 requested
Standard version
€ 97,- 97,-
FWEC2A
Controller electronic FWEC2A
EPIB6 requested
Advanced version
€ 152,- 152,-
FWEC3A
Controller electronic FWEC3A
EPIB6 requested
Advanced Plus version
€ 208,- 208,-
Wall mounting kit (spacing collar) FWFCKA
for FWEC*A € 16,-
Temperature sensor kit FWTSKA
for FWEC*A € 8,-
Relative humidity sensor kit FWHSKA
for FWEC2A and FWEC3A € 23,-
Master / Slave interface EPIMSB6
€ 159,-
EPIB6
Power interface –
€ 159,-
Note:
For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers.
If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSB6 still EPIB6 needs to be used for each FWD to connect to EPIMSB6.

Applied Systems Price list 2015-201615

AS_RS&MNE.indd 15 30.4.2015 г. 15:12:08 ч.


FWF-C, FWF-B, FWC-B, Cassette fan coils

FWF-C
Fan coil

Infrared remote control as standard with decoration panel kit.

FWF-C cassette unit 02 03 04


FWF**CT, 2 pipe unit,
€ 510,- 574,- 582,-
incl. condensate pump, without valves
Cooling capacity (Total at High Speed) kW 2,49 4,10 4,54
Heating capacity (2-pipe at High Speed) kW 3,52 4,69 5,28

Note: Decoration panel is mandatory, it is included with other accessories in table on page 17.

FWF-B
Fan coil

Possibility to shut 1 or 2 flaps for easy installations in corners.

FWF-B cassette unit 02 03 04 05


FWF**BT, 2 pipe unit,
€ 708,- 776,- 832,- 878,-
incl. condensate pump, without valves
Cooling capacity (Total at Super High Speed) kW 2,00 3,20 4,20 5,20
Heating capacity (2-pipe at Super High Speed) kW 2,90 4,00 5,40 6,70
FWF**BF, 4 pipe unit,
€ 787,- 857,- 900,- 944,-
incl. condensate pump, without valves
Cooling capacity (Total at Super High Speed) kW 2,00 2,70 3,50 4,50
Heating capacity (4-pipe at Super High Speed) kW 3,80 3,80 4,90 6,10

Note: Decoration panel is mandatory, it is included with other accessories in table on page 18.

FWC-B
Fan coil

360° air discharge ensures uniform air flow and temperature


distribution.

FWC-B cassette unit 06 07 08 09


FWC**BT, 2 pipe unit,
€ 1.024,- 1.055,- 1.105,- 1.146,-
incl. condensate pump, without valves
Cooling capacity (Total at High Speed) kW 5,80 6,80 7,70 8,70
Heating capacity (2-pipe at High Speed) kW 8,00 8,90 10,60 12,10
FWC**BF, 4 pipe unit,
€ 1.096,- 1.129,- 1.163,- 1.204,-
incl. condensate pump, without valves
Cooling capacity (Total at High Speed) kW 5,80 6,60 7,60 8,70
Heating capacity (4-pipe at High Speed) kW 7,50 8,40 9,70 11,00

Note: Decoration panel is mandatory, it is included with other accessories in table on page 18.

16

AS_RS&MNE.indd 16 30.4.2015 г. 15:12:09 ч.


FWG-A cassette fan coil, FWT-C Wall mounted fan coil, Accessories for FWT-C, FWF-C, FWG-A,

FWG - A
Cassette fan coils with DC fan motor

Low sound level and up to 70% energy saving thanks to the


BLDC motor technology infrared remote control is standard with
decoration panel kit.

FWG - A cassette unit 05 08 11


FWG**AT 2 pipe unit ,
€ 1.068,- 1.175,- 1.241,-
incl. condensate pump, without valves
Cooling Capacity (Total at High Speed) kW 5.90 8.80 11.75
Heating Capacity (2 pipe at High Speed) kW 7.10 11.20 13.70
FWG**AF 4 pipe unit ,
€ 1.167,- 1.280,- 1.342,-
incl. condensate pump, without valves
Cooling Capacity (Total at High Speed) kW 4.40 7.20 9.00
Heating Capacity (4 pipe at High Speed) kW 7.65 11.20 15.65

Note: Decoration panel is mandatory, it is include with other accessories in below table

Accessories for FWG - A


Decoration Panel / FWG AT 2 pipes DCP900BTA
include GS02 wireless controller € 172,-
Decoration Panel / FWG AF 4 pipes DCP900BFA
include GS02 wireless controller € 172,-
Wired controller BRC51A61
€ 106,-
Wireless controller Type GS02
Decoration panel already include € Decoration panel already indlude
Valve kit 3-ways ON/OFF 230 V VKFWGA012T3V VKFWGA022T3V
2 pipe version € 127,- 137,-
Valve kit 3-ways ON/OFF 230 V VKFWGA014T3V VKFWGA024T3V
4 pipe version € 257,- 268,-

FWT-C
Fan coil

Flexibility via interchangeable water connection side.

FWT-C wall mounted unit 02 03 04 05 06


FWT**CT, 2 pipe unit,
€ 322,- 359,- 365,- 496,- 506,-
without valves
Cooling capacity (Total at High Speed) kW 2,34 2,78 3,22 4,54 5,28
Heating capacity (2-pipe at High Speed) kW 3,02 3,75 4,10 6,01 6,74

FWT-C + FWF-C
Accessories
Type FWF-CT FWT-CT
Decoration panel 2-pipe DCP600TC

Incl. wireless controller € 184,-
Standard wired remote control MERCA
€ 140,-
Simplified wired remote control SRC-COA
€ 71,-
Simplified wired remote control SRC-HPA
€ 71,-
Wireless control WRC-HPC
€ 28,-
2-pipe 3-way valve MCKCW2T3VN

€ 129,-

Applied Systems Price list 2015-201617

AS_RS&MNE.indd 17 30.4.2015 г. 15:12:10 ч.


Accessories for FWC-B, FWF-B

FWC-B, FWF-B
Accessories

Options FWC-B FWF-B


BYCQ140C
Decoration Panel Round Flow Standard -
€ 277,-
BYFQ60B3
Decoration Panel 4-way blow -
€ 183,-
KDBHQ55C140 KDBH44BA60
Sealing member of air discharge outlet
€ 114,- 136,-
KAFP551K160 KAFQ441BA60
Long-life filter
€ 108,- on request
KDBQ44B60
Panel spacer -
€ 512,-
CE.KDDQ55C140 KDDQ44XA60
Fresh air intake kit
€ 578,- 171,-

Control Systems
BRC7F532F (11) BRC7E530 (11)
Remote control Infrared H/P
€ 176,- 176,-
BRC7F533F (11) BRC7E531 (11)
Remote control Infrared C/O
€ 134,- 309,-
BRC315D (1)
Remote Control Wired
€ 120,-
DCS302C51 (2)
Central remote control
€ 1.455,-
Electrical box with earth terminal (3 KJB311A
blocks) € 93,-
DCS301B51 (5)
Unified on/off control
€ 613,-
Electrical box with earth terminal (2 KJB212A
blocks) € 81,-
DST301B51 (5)(8)
Shedule timer
€ 765,-
Wiring adapter for electrical KRP2A52 (4)(8)
appendices 1 € 372,-
Wiring adapter for electrical KRP4A53 (4)(8)
appendices 2 € 207,-
KRP1H98 (9) KRP1BA101 (9)
Installation box for adapter PCB
€ 54,- 72,-
KRCS01-4 KRCS01-1
Remote Sensor
€ 82,- 82,-
DCS601C51 (3)(7)
Intelligent touch controller
€ 2.020,-
KJB411A
Electrical installation box
€ 153,-
EKFCMBCB (4)(8)
Optional PCB for MOD-bus connection
€ 117,-
EKMV2C09B (4)(6)(10)
2-way valve - On/Off
€ 98,-
EKMV3C09B (4)(6)(10)
3-way valve - On/Off
€ 112,-
EKRP1C11
Valve control PCB
€ 85,-
EKRORO (12)
Remote “On/Off” and “forced off” kit -
€ 28,-
Notes:
1. Optional, electrical installation box with earth terminal KJB212A is required, if 10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve
controller wires need to be installed in the wall. control PCB EKRP1C11
2. Requires electrical installation box with earth terminal KJB311A. FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve
3. Requires electrical installation box KJB411A. control PCB EKRP1C11
4. Requires installation box KRP1H98 for FWC-B and KRP1BA101 for FWF-B. FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve
5. Requires electrical installation box with earth terminal KJB212A, if built in the wall. control PCB EKRP1C11.
6. Requires valve control PCB EKRP1C11. FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve
7. I-touch: control PCB EKRP1C11.
• Not allowed to use the i-touch for an installation with both fan coils and VRV 11. It is possible to change the operation mode, but this will not have an impact on
units. the water temperature.
• Can not be used in combination with fan coil units, that use MOD bus (No feed back to water source)
communication. It is not possible to select the “auto air flow” setting.
• No Airnet or telephone connection possible. Dry operation can be selected with this remote control, but this function is not
8. Only 1 of these 4 options can be installed on 1 indoor unit. available on the FWC-B / FWF-B model.
9. FWC -B: Max. 1 KRP1H98 box can be mounted on the unit. 12. This option is needed to create T1 T2 wire.
Max. 2 PCB’s can be mounted in 1 KRP1H98 box.
FWF-B: Max. 2 KRP1BA101 boxes can be mounted on the unit. All options are supplied as kit.
Max. 1 PCB can be mounted in 1 KRP1BA101 box.

18

AS_RS&MNE.indd 18 30.4.2015 г. 15:12:11 ч.


FWV - D, Floor standing fan coil

FWV - D
Fan coil

Low Wall unit FWV 01 15 02 25 03 35 04 06 08 10


FWV**DTN, 2 pipe unit,
€ 312,- 327,- 343,- 369,- 378,- 416,- 436,- 471,- 624,- 710,-
standard, without valve
FWV**DTV, 2 pipe unit,
€ 529,- 546,- 564,- 588,- 597,- 637,- 659,- 694,- 867,- 952,-
with 3-way on/off 230V valve, factory mounted
FWV**DTD, 2 pipe unit, with simplified 3-way on/off
€ 405,- 417,- 432,- 458,- 467,- 500,- 527,- 562,- 712,- 791,-
230V valve, factory mounted
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWV**DFN, 4 pipe unit,
€ 361,- 381,- 398,- 426,- 438,- 475,- 508,- 549,- 717,- 801,-
standard, without valves
FWV**DFV, 4 pipe unit, with 3-way on/off 230V
€ 756,- 775,- 789,- 819,- 832,- 868,- 902,- 940,- 1.130,- 1.216,-
valves, factory mounted
FWV**DFD, 4 pipe unit, with simplified 3-way on/off
€ 557,- 574,- 591,- 617,- 630,- 665,- 708,- 747,- 915,- 995,-
230V valves, factory mounted
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating capacity (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35

Factory mounted options 01 15 02 25 03 35 04 06 08 10


3-way on/off 24V valve € on request
3-way proportional on/off valves € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
2-way proportional on/off valve € on request
4-rows coil (for 2 pipe unit only) € on request
6-speeds fan motor € - on request - on r.
Electric heater (for 2 pipe unit only) € on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10


FWEC1A Standard version € on request
FWEC2A Advanced version € on request
FWEC3A Advanced Plus version € on request

Notes:
Accessories as kits are included on page 22.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2015-201619

AS_RS&MNE.indd 19 30.4.2015 г. 15:12:11 ч.


FWL - D, Flexi type fan coil

FWL - D
Fan coil

Flexible unit FWL 01 15 02 25 03 35 04 06 08 10


FWL**DTN, 2 pipe unit,
€ 326,- 344,- 366,- 384,- 405,- 438,- 460,- 496,- 667,- 756,-
standard, without valve
FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve,
€ 541,- 561,- 578,- 598,- 620,- 657,- 683,- 717,- 907,- 993,-
factory mounted
FWL**DTD, 2 pipe unit, with simplified 3-way on/off
€ 508,- 527,- 553,- 573,- 601,- 636,- 671,- 712,- 915,- 1.016,-
230V valve, factory mounted
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWL**DFN, 4 pipe unit,
€ 382,- 401,- 413,- 445,- 460,- 512,- 539,- 572,- 762,- 843,-
standard, without valves
FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves,
€ 770,- 787,- 801,- 834,- 847,- 898,- 925,- 958,- 1.167,- 1.251,-
factory mounted
FWL**DFD, 4 pipe unit, with simplified 3-way on/off
€ 574,- 591,- 603,- 634,- 652,- 696,- 731,- 766,- 956,- 1.034,-
230V valves, factory mounted
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35

Factory mounted options 01 15 02 25 03 35 04 06 08 10


3-way on/off 24V valve € on request
3-way proportional on/off valves € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
2-way proportional on/off valve € on request
4-rows coil (for 2 pipe unit only) € on request
6-speeds fan motor € - on request - on r.
Electric heater (for 2 pipe unit only) € on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10


FWEC1A Standard version € on request
FWEC2A Advanced version € on request
FWEC3A Advanced Plus version € on request

Notes:
Accessories as kits are included on page 22.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.

20

AS_RS&MNE.indd 20 30.4.2015 г. 15:12:12 ч.


FWM - D, Flexi concealed fan coil

FWM - D
Fan coil

Flexible concealed unit FWM 01 15 02 25 03 35 04 06 08 10


FWM**DTN, 2 pipe unit,
€ 260,- 275,- 287,- 306,- 316,- 342,- 357,- 388,- 514,- 582,-
standard, without valve
FWM**DTV, 2 pipe unit,
€ 479,- 491,- 500,- 521,- 529,- 559,- 574,- 611,- 752,- 818,-
with 3-way on/off 230V valve, factory mounted
FWM**DTD, 2 pipe unit, with simplified
€ 378,- 394,- 405,- 425,- 436,- 461,- 485,- 518,- 648,- 719,-
3-way on/off 230V valve, factory mounted
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWM**DFN, 4 pipe unit,
€ 312,- 324,- 334,- 366,- 376,- 411,- 430,- 460,- 603,- 675,-
standard, without valves
FWM**DFV, 4 pipe unit, with 3-way on/off 230V
€ 696,- 712,- 719,- 750,- 762,- 793,- 816,- 847,- 1.008,- 1.080,-
valves, factory mounted
FWM**DFD, 4 pipe unit, with simplified 3-way on/off
€ 547,- 558,- 568,- 601,- 609,- 648,- 679,- 708,- 861,- 937,-
230V valves, factory mounted
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating capacity (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35

Factory mounted options 01 15 02 25 03 35 04 06 08 10


3-way on/off 24V valve € on request
3-way proportional on/off valves € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
2-way proportional on/off valve € on request
4-rows coil (for 2 pipe unit only) € on request
6-speeds fan motor € - on request - on r.
Electric heater (for 2 pipe unit only) € on request

Notes:
Accessories as kits are included on page 22.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2015-201621

AS_RS&MNE.indd 21 30.4.2015 г. 15:12:12 ч.


Accessories for FWV - FWL - FWM

FWV – FWL – FWM


Accessories

Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10


ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6
Additional heat exchanger
€ 61,- 73,- 81,- 106,-
EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6
Electric heater
€ 273,- 273,- 294,- 306,- 317,-
E2MV03A6 E2MV06A6 E2MV10A6
2-pipe 3-ways 230V on/off valve kit
€ 191,- 205,- 220,-
E4MV03A6 E4MV06A6 E4MV10A6
4-pipe 3-ways 230V on/off valve kit
€ 358,- 373,- 390,-
E2MV2B07A6 E2MV2B10A6
2-ways 230V on/off valve kit cooling h/e
€ 100,- 105,-
E2MV2B07A6
2-ways 230V on/off valve kit additional h/e
€ 100,-
E2MVD03A6 E2MVD06A6 E2MVD10A6
2-pipe simplified 3-ways 230V on/off valve kit
€ 136,- 138,- 138,-
E4MVD03A6 E4MVD06A6 E4MVD10A6
4-pipe simplified 3-ways 230V on/off valve kit
€ 249,- 255,- 258,-
E2M2V03A6 E2M2V06A6 E2M2V10A6
2-pipe 3-ways 24V on/off valve kit
€ 233,- 233,- 246,-
E4M2V03A6 E4M2V06A6 E4M2V10A6
4-pipe 3-ways 24V on/off valve kit
€ 415,- 415,- 438,-
E2MPV03A6 E2MPV06A6 E2MPV10A6
2-pipe 3-ways proportional valve kit
€ 366,- 361,- 371,-
E4MPV03A6 E4MPV06A6 E4MPV10A6
4-pipe 3-ways proportional valve kit
€ 674,- 676,- 684,-
E2M2V207A6 E2M2V210A6
2-ways 24V on/off valve kit cooling h/e
€ 100,- 100,-
E2M2V207A6
2-ways 24V on/off valve kit additional h/e
€ 100,-
E2MPV207A6 E2MPV210A6
2-ways proportional valve kit cooling h/e
€ 255,- 255,-
E2MPV207A6
2-ways proportional valve kit additional h/e
€ 255,-
YFSTA6
Fan stop thermostat
€ 18,-
EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6
Air intake & discharge grille
€ 176,- 217,- 271,- 320,-
ESFV06A6 ESFV10A6
Supporting feet
€ 18,- 23,-
ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6
Supporting feet & grille
€ 31,- 38,- 43,- 59,-
EFA02A6 EFA03A6 EFA06A6 EFA10A6
Fresh air intake
€ 78,- 79,- 88,- 99,-
ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6
Rear panel
€ 33,- 45,- 51,- 65,-
Plenum box with circular connections EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6
(only for FWM-D) € 103,- 113,- 141,- 197,-
EDPVB6
Vertical auxiliary drainpan
€ 5,-
EDPHB6
Horizontal auxiliary drainpan
€ 5,-

Controller as a kit for FWV/FWL/FWM all sizes


ECFWMB6 Controller electromechanical, Built in € 39,-
Wired remote controller,
FWEC1A € 97,-
Standard version
Wired remote controller,
FWEC2A € 152,-
Advanced version
Wired remote controller,
FWEC3A € 208,-
Advanced Plus version
On board mounting kit, for FWEC*A,
FWECKA € 16,-
remote airprobe incl.
Wall mounting kit (spacing collar), for
FWFCKA € 16,-
FWEC*A
FWTSKA Temperature sensor kit , for FWEC*A € 8,-
Relative humidity sensor kit ,
FWHSKA € 23,-
for FWEC2A and FWEC3A
EPIMSB6 Master / Slave interface € 159,-

22

AS_RS&MNE.indd 22 30.4.2015 г. 15:12:12 ч.


FWZ - A, Floor standing fan coil with DC fan motor

FWZ - A
Fan coil

Low sound level and up to 70% energy saving thanks to the BLDC
motor technology

Low Wall unit with DC fan motor FWZ 02 03 06 08


FWZ**ATN, 2 pipe unit,
€ 493,- 522,- 603,- 754,-
standard, without valve
FWZ**ATV, 2 pipe unit,
€ 696,- 723,- 812,- 979,-
with 3-way on/off 230V valve, factory mounted
FWZ**ATD, 2 pipe unit, with simplified 3-way on/off
€ 599,- 626,- 712,- 871,-
230V valve, factory mounted
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWZ**AFN, 4 pipe unit,
€ 535,- 570,- 677,- 828,-
standard, without valves
FWZ**AFV, 4 pipe unit, with 3-way on/off 230V
€ 904,- 937,- 1.043,- 1.218,-
valves, factory mounted
FWZ**AFD, 4 pipe unit, with simplified 3-way on/off
€ 747,- 780,- 898,- 1.061,-
230V valves, factory mounted
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06

Factory mounted options 02 03 06 08


3-way on/off 24V valve € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
4-rows coil (for 2 pipe unit only) € on request
Electric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08


FWEC3A Advanced Plus version € on request

Notes:
Accessories as kits are included on page 26.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2015-201623

AS_RS&MNE.indd 23 30.4.2015 г. 15:12:13 ч.


FWR - A, Flexi type fan coil with DC fan motor

FWR - A
Fan coil

Low sound level and up to 70% energy saving thanks to the BLDC
motor technology

FLEXI type unit with DC fan motor FWR 02 03 06 08


FWR**ATN, 2 pipe unit,
€ 514,- 557,- 644,- 822,-
standard, without valve
FWR**ATV, 2 pipe unit,
€ 717,- 760,- 853,- 1.047,-
with 3-way on/off 230V valve, factory mounted
FWR**ATD, 2 pipe unit, with simplified 3-way on/off
€ 620,- 663,- 754,- 937,-
230V valve, factory mounted
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWR**AFN, 4 pipe unit,
€ 562,- 607,- 712,- 906,-
standard, without valves
FWR**AFV, 4 pipe unit, with 3-way on/off 230V
€ 929,- 973,- 1.082,- 1.293,-
valves, factory mounted
FWR**AFD, 4 pipe unit, with simplified 3-way on/off
€ 772,- 818,- 935,- 1.136,-
230V valves, factory mounted
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06

Factory mounted options 02 03 06 08


3-way on/off 24V valve € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
4-rows coil (for 2 pipe unit only) € on request
Electric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08


FWEC3A Advanced Plus version € on request

Notes:
Accessories as kits are included on page 26.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.

24

AS_RS&MNE.indd 24 30.4.2015 г. 15:12:14 ч.


FWS - A, Flexi type fan coil with DC fan motor

FWS - A
Fan coil

Low sound level and up to 70% energy saving thanks to the BLDC
motor technology

FLEXI type unit with DC fan motor FWS 02 03 06 08


FWS**ATN, 2 pipe unit,
€ 440,- 471,- 541,- 675,-
standard, without valve
FWS**ATV, 2 pipe unit,
€ 646,- 675,- 750,- 902,-
with 3-way on/off 230V valve, factory mounted
FWS**ATD, 2 pipe unit, with simplified 3-way on/off
€ 547,- 576,- 653,- 791,-
230V valve, factory mounted
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWS**AFN, 4 pipe unit,
€ 485,- 527,- 607,- 758,-
standard, without valves
FWS**AFV, 4 pipe unit, with 3-way on/off 230V
€ 855,- 898,- 973,- 1.146,-
valves, factory mounted
FWS**AFD, 4 pipe unit, with simplified 3-way on/off
€ 696,- 739,- 826,- 987,-
230V valves, factory mounted
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06

Factory mounted options 02 03 06 08


3-way on/off 24V valve € on request
2-way on/off 230V valve € on request
2-way on/off 24V valves € on request
4-rows coil (for 2 pipe unit only) € on request
Electric heater (for 2 pipe unit only) € on request

Factory mounted options 02 03 06 08


FWEC3A Advanced Plus version € on request

Notes:
Accessories as kits are included on page 26.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.

Applied Systems Price list 2015-201625

AS_RS&MNE.indd 25 30.4.2015 г. 15:12:14 ч.


Accessories for FWZ - FWR - FWS

FWZ - FWR - FWS


Accessories

Accessories as a kit for FWZ/FWR/FWS 02 03 06 08


ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6
Additional heat exchanger
€ 61,- 73,- 81,- 106,-
EEH02A6 EEH03A6 EEH06A6 EEH10A6
Electric heater
€ 273,- 294,- 306,- 317,-
E2MV03A6 E2MV06A6 E2MV10A6
2-pipe 3-ways 230V on/off valve kit
€ 191,- 205,- 220,-
E4MV03A6 E4MV06A6 E4MV10A6
4-pipe 3-ways 230V on/off valve kit
€ 358,- 373,- 390,-
E2MV2B07A6 E2MV2B10A6
2-ways 230V on/off valve kit cooling h/e
€ 100,- 105,-
E2MV2B07A6
2-ways 230V on/off valve kit additional h/e
€ 100,-
E2MVD03A6 E2MVD06A6 E2MVD10A6
2-pipe simplified 3-ways 230V on/off valve kit
€ 136,- 138,- 138,-
E4MVD03A6 E4MVD06A6 E4MVD10A6
4-pipe simplified 3-ways 230V on/off valve kit
€ 249,- 255,- 258,-
E2M2V03A6 E2M2V06A6 E2M2V10A6
2-pipe 3-ways 24V on/off valve kit
€ 233,- 233,- 246,-
E4M2V03A6 E4M2V06A6 E4M2V10A6
4-pipe 3-ways 24V on/off valve kit
€ 415,- 415,- 438,-
E2M2V207A6 E2M2V210A6
2-ways 24V on/off valve kit cooling h/e
€ 100,- 100,-
E2M2V207A6
2-ways 24V on/off valve kit additional h/e
€ 100,-
EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6
Air intake & discharge grille
€ 176,- 217,- 271,- 320,-
ESFV06A6 ESFV10A6
Supporting feet
€ 18,- 23,-
ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6
Supporting feet & grille
€ 31,- 38,- 43,- 59,-
EFA02A6 EFA03A6 EFA06A6 EFA10A6
Fresh air intake
€ 78,- 79,- 88,- 99,-
ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6
Rear panel
€ 33,- 45,- 51,- 65,-
Plenum box with circular connections EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6
(only for FWS-A) € 103,- 113,- 141,- 197,-
EDPVB6
Vertical auxiliary drainpan
€ 5,-
EDPHB6
Horizontal auxiliary drainpan
€ 5,-

Controller as a kit for FWZ / FWR / FWS all sizes


Wired remote controller,
FWEC3A € 208,-
Advanced Plus version
On board mounting kit, for FWEC*A,
FWECKA € 16,-
remote airprobe incl.
Wall mounting kit (spacing collar), for
FWFCKA € 16,-
FWEC*A
Temperature sensor kit,
FWTSKA € 8,-
for FWEC*A
Relative humidity sensor kit ,
FWHSKA € 23,-
for FWEC2A and FWEC3A

26

AS_RS&MNE.indd 26 30.4.2015 г. 15:12:14 ч.


Air Handling Units - AHU

D-AHU Modular Series


D-AHU Modular specification:

Panel type:
ʯʯ Internal Skin Material: Aluzinc®
ʯʯ External Skin finishing: Aluzinc® or Pre-Painted
ʯʯ Insulation material: Mineral Wool or Polyurethane
ʯʯ Panel Type: SP45

Construction Structure:
ʯʯ Frame: Anodized Aluminum
ʯʯ Frame Type: Internal Rounded

Main Components & Calculation input:


ʯʯ Heat Wheel: Sensible type
ʯʯ Fans (Standard Pressure): EC Fan IE4 Mot.
ʯʯ Unit Installation: Indoor (without roof )
ʯʯ Filters Efficiency: G4 / G7

Main Module Configuration:


ʯʯ Plug & Play factory mounted Controls

Main module nominal Performances


Size 1 2 3 4 5 6 7 8 9 10
Airflow m3/h 1200 1700 2700 4100 5500 6100 7000 9100 11500 15000
Temp efficiency winter % 81.3 81.1 81.4 81.6 82.6 81.2 82.7 81.4 81.5 83.2
ESP nominal Pa 200 200 200 200 200 200 200 200 200 200
Current nominal A 2.66 3.9 6.3 2.98 4 4.74 4.76 5.54 8.72 10.2
Power input nominal kW 0.62 0.89 1.5 1.98 2.68 2.96 3.3 3.76 5.48 7.04
SFPv kW/m3/s 1.87 1.89 1.99 1.74 1.75 1.75 1.7 1.49 1.72 1.69
400-3+N- 400-3+N- 400-3+N- 400-3+N- 400-3+N- 400-3+N- 400-3+N-
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50
50 50 50 50 50 50 50
Lenght mm 1700 1700 1800 1920 2080 2280 2400 2450 2280 2400
Depth mm 720 820 990 1200 1400 1400 1600 1940 1940 2300
Height overall mm 1320 1320 1540 1740 1740 1920 1920 2180 2460 2570
Weight kg 325 350 475 575 750 790 950 1330 1410 1750
Sound level - Lp* dB(A) 40 42 42 45 46 44 43 43 45 45
* Sound pressure level radiated from unit at 1 meter and according to ISO 3744 (supply outlet ducted)
Size 1 2 3 4 5 6 7 8 9 10
Main Module € 12.346,- 12.787,- 14.373,- 15.782,- 17.192,- 18.316,- 20.277,- 23.630,- 27.126,- 30.397,-

Size 1 2 3 4 5 6 7 8 9 10
Mode Coil's Row
Cooling Coil 6 € 1.946,- 2.137,- 2.512,- 2.998,- 3.380,- 4.060,- 3.517,- 4.585,- 4.954,- 5.747,-
Cooling+Heating
6+2 € 2.774,- 2.989,- 3.422,- 4.101,- 4.545,- 5.291,- 4.808,- 6.027,- 5.944,- 8.226,-
Coil
Dx HP 4 € 2.444,- 2.528,- 2.778,- 4.146,- 4.337,- 4.656,- - - - -

Size 1 2 3 4 5 6 7 8 9 10
Three way mixing box € 1.034,- 1.053,- 1.130,- 1.281,- 1.362,- 1.401,- 1.619,- 1.842,- 2.006,- 2.179,-

Size 1 2 3 4 5 6 7 8 9 10
Outdoor Kit (Roof) € 248,- 271,- 331,- 421,- 540,- 567,- 626,- 763,- 811,- 910,-

Size 1 2 3 4 5 6 7 8 9 10
M6 Filter
€ 135,- 135,- 227,- 269,- 361,- 361,- 403,- 644,- 644,- 862,-
(to replace G4)
Additional Filtration Module
€ 1.365,- 1.404,- 1.645,- 1.908,- 2.102,- 2.298,- 2.680,- 3.163,- 3.708,- 3.938,-
F9 front withdrawal

Size 1 2 3 4 5 6 7 8 9 10
Sorption Type Heat Wheel
(to replace sensible type on main € 1.187,- 1.347,- 1.705,- 2.253,- 2.570,- 2.763,- 3.306,- 3.756,- 4.486,- 6.146,-
module)

Size 1 2 3 4 5 6 7 8 9 10
Bacnet Module
€ 269,-
(for ITM Daikin)

Applied Systems Price list 2015-201627

AS_RS&MNE.indd 27 30.4.2015 г. 15:12:17 ч.


Air cooled and condensing units

Products overview
Compressor Water heat exchanger Efficiency version Sound version

Refrigerant circuit(s)
Refrigerant type

Single pass shell

High ambient
Brazed plate
Free cooling

exchanger
Plate heat

Extra low
Standard

Standard
Premium
and tube

Reduced
Inverter

Swing

Screw
Scroll

High

Low
Cooling only
0

EWAQ~ADVP R-410A 1     
EWAQ~ACV3/acw1 R-410A 1     
EWAQ~BA* R-410A 1     
EWAQ~G NEW R-410A 1     
EWAQ~E- R-410A 1      
EWAQ~F- R-410A 2       
EWAQ~GZ R-410A 1-2      
EWAD~E- R-134a 1     
EWAD~D- R-134a 2          
EWAD~TZ R-134a 1-2        
EWAD~C- R-134a 2-3        
EWAD~CZ R-134a 2-3       
EWAD~CF R-134a 2       
Heat pump
0

EWYQ~ADVP R-410A 1     
EWYQ~ACV3/ACW1 R-410A 1     
EWYQ~BA* R-410A 1     
SEHVX-AAW
SERHQ-AAW1
NEW R-410A 1     
EWYQ~F- R-410A 2      
EWYQ~GZ R-410A 1-2      
EWYD~BZ R-134a 2-3      
Condensing unit
0

ERAD~E- R-134a 1    

28

AS_RS&MNE.indd 28 30.4.2015 г. 15:12:27 ч.


Air cooled and condensing units

on
Extra low

Cooling capacity (kW)


Heating capacity (kW)

0 17.5 200 500 1,000 2,000

5.3~7.2

8.6~17.0

16.6~64.5

75~160 kW

172~334

165~672

196~395

98~411

 177~620

170~710

696~1,795

602~1,555

617~2,002

0 17.5 200 500 1,000 2,000


5.3~7.2
5.6~8.2
8.6~17.0
9.9~14.8
16.6~64.5
16.2~63.7
20.7~74.3
21.3~63.7
158~624
173~674
188~380
182~362
247~580
271~618

0 17.5 200 500 1,000 2,000

116~488

Applied Systems Price list 2015-201629

AS_RS&MNE.indd 29 30.4.2015 г. 15:12:28 ч.


Water cooled and condenserless units

Products overview
Compressor Water heat exchanger Efficiency version

Refrigerant type

shell and tube


Brazed plate
Refrigerant

Centrifugal

Single pass
exchanger
Plate heat

Standard
circuit(s)

Inverter

Screw
Scroll

High
Water cooled Scroll and Screw chillers
0

EWWP~KBW1N R-407C 1-2-4-6   


EWWQ-G NEW R-410A 1   
EWWQ-L NEW R-410A 2   
EWWD~J- R-134a 1-2   
EWWD~G- R-134a 1-2    
EWWD~I- R-134a 1-2-3    
EWWD~H- R-134a 1  
Flooded 
EWWQ~B- R-410A 1-2    
Condenserless chillers
0

EWLP~KBW1N R-407C 1-2   


EWLQ-G NEW R-410A 1   
EWLQ - L NEW R-410A 2   
EWLD~J- R-134a 1-2   
EWLD~G- R-134a 1-2   
EWLD~I- R-134a 1-2-3   
Water cooled centrifugal chillers
0

EWWD~FZ R-134a 1   
Flooded 
DWSC
DWDC
R-134a optional  
6,000 RT
CENTRIFUGAL
R-134a  

Large Chillers options and accessories summary


ʯʯ Depending on the type and size of chiller a wide range of options and accessories is available. E.g.

ʯʯ Brine (glycol) application ʯʯ Flow switch for evaporator ʯʯ Set point reset and demand limit
ʯʯ Star delta compressor starter (kit for field installation) possibility
ʯʯ Thermal relays for compressors ʯʯ Victaulic connections ʯʯ General fault contact
ʯʯ Thermal relays for fans ʯʯ Rubber type ant vibration mounts ʯʯ Single pump
ʯʯ Under/over voltage controller ʯʯ Evaporator heater ʯʯ Twin pump
ʯʯ Phase monitor device ʯʯ Main switch ʯʯ Total heat recovery
ʯʯ Condenser coils with special ʯʯ Suction and discharge stop valves on ʯʯ Partial heat recovery
anti corrosion treatment compressors ʯʯ Low ambient application
ʯʯ Dual set point possibility ʯʯ Power factor 0.9 correction device
30

AS_RS&MNE.indd 30 30.4.2015 г. 15:12:39 ч.


Water cooled and condenserless units

rsion
High

Cooling capacity (kW)


Heating capacity (kW)

0 17.5 200 500 1,000 2,000 21800


12.9~194
16.7~249
93~415
110~510
184~722
225~885
120~568
142~681
165~602
 209~743
332~1,503
 424~1,951
368~1,212
 454~1,488

 379~2,156

0 17.5 200 500 1,000 2,000 21800

12.1~62.4

93~415

184~722

110~529

160~524

315~1,433

0 17.5 200 500 1,000 2,000 21800

 113~1,054

300~4,500
 600~9,000

[ 2 x 10,900 ] 21,800

Daikin Europe N.V. participates in the Eurovent Certification programme Air cooled: Eurovent certified up to 600kW
for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units Water cooled: Eurovent certified up to 1500kW
(AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: Nominal cooling capacities are based on Eurovent conditions:
www.eurovent-certification.com or using: www.certiflash.com Evaporator: 12°C/7°C — Ambient: 35°C
Nominal heating capacities are based on Eurovent conditions:
Ambient: 7°CDB/6°CWB — Condenser: 40°C/45°C

ʯʯ A/V meter ʯʯ Dual pressure relieves safety valves For the exact availability of the chiller
ʯʯ Coil guards ʯʯ Different address card which fits best your application please
ʯʯ Soft starter ʯʯ Different bus communication get in contact with your Daikin sales
ʯʯ Low noise version gateways (LonTalk, Bacnet, responsible.
ʯʯ Refrigerant Gauges Modbus,…)
ʯʯ Coil guards ʯʯ Chiller Sequencing Panel
ʯʯ Cu/Cu condenser coils ʯʯ Different Modems (fixed and GSM)
ʯʯ High ESP fans ʯʯ Plant Watch PRO monitoring system
ʯʯ Cu/Ni heat exchanger ʯʯ Remote user interface
Applied Systems Price list 2015-201631

AS_RS&MNE.indd 31 30.4.2015 г. 15:12:39 ч.


Total solution products

Air Cooler COOLING TOWER


1-162 kW 70-9.200 kW

On request we can offer you the most suita- On request we can offer you the most suita-
ble air cooler for your application based on ble cooling tower for your application.
a brine/water solution. For correct selection we need following info:
ʯʯ Heat rejection capacity (kW) or chiller type
and working conditions
ʯʯ Liquid inlet and outlet temperature
ʯʯ Liquid type
ʯʯ Maximum/Minimum ambient temperature
Air Handling Unit3
ʯʯ Maximum sound level
500-140.000 m /h ʯʯ Space restrictions

On request we can offer you the most suitable air handling unit for
your application.
ʯʯ Air handling units for filtering, heating, cool-
ing, humidifying, and air drying
ʯʯ Air handling units with heat recovery Compressor
ʯʯ Air handling units for outdoor installation Inspection/repair/overhaul
ʯʯ Air handling units in hygienic execution for
hospital and clean room To extend the lifetime of your compressor, Daikin
ʯʯ Air handling units with indirect gas fired offers a compressor overhaul service as preventive
heating maintenance.
ʯʯ Air handling units for swimming pool applications In case of broken compressor, Daikin can offer an
ʯʯ Air handling units with higher air volumes manufactured on inspection to determine whether the compressor is repairable or
request not. Based on the findings the broken parts will be replaced and the
ʯʯ Air handling units with thermal uncoupled frame compressor will be restored into operational condition.

Inspection
Inspection fee/compressor* on request

Repair

DRY Cooler & Repair cost/compressor* After inspection, on quotation base

CONDENSER Overhaul
Overhaul cost/compressor* on request
3-2.400 kW
Remarks
On request we can offer you the most suitable The above is only valid for DAIKIN semi-hermetic compressors
dry cooler and condenser for your application. * Excluding transport cost and other site related costs
For correct selection we need following info:
ʯʯ Heat rejection capacity (kW) or chiller type
and working conditions
ʯʯ Liquid inlet and outlet temperature (dry
cooler)
ʯʯ Liquid type (dry cooler)
ʯʯ Condensing temperature (condenser)
ʯʯ Refrigerant type and number of circuits
(condenser)
ʯʯ Maximum/Minimum ambient temperature
ʯʯ Maximum sound level
ʯʯ Space restrictions

32

AS_RS&MNE.indd 32 30.4.2015 г. 15:12:40 ч.


Measuring conditions

Mentioned Capacities, Efficiency Ratios, Sound power


levels, Dimensions
Weights are indicative and valid under the following conditions:

Chillers
Cooling 7 °C / 12 °C water 35 °C ambient temp
Air cooled units Heating 40 °C / 45 °C water 7 °C ambient temp
Heat recovery 7 °C / 12 °C water 40°C / 45°C heat recovery 35 °C ambient temp
Condenserless units Cooling 7 °C / 12 °C water 45 °C condensing temp / 5 K subcooling
Cooling 7 °C / 12 °C evaporator water 30 °C / 35 °C condenser water
Water cooled units
Heating 7 °C / 12 °C evaporator water 40 °C / 45 °C condenser water

Rooftops
Cooling: indoor temperature: 27 °C db / 19 °C wb outdoor temperature: 35 °C
Heating: indoor temperature: 20 °C db outdoor temperature: 7 °C db / 6 °C wb

Condensing units
Cooling: evaporation temperature: 6 °C outdoor temperature: 35 °C on-coil temperature: 27 °CDB / 19 °CWB
Heating: condensing temperature: 46 °C outdoor temperature: 7 °C on-coil temperature: 20 °CDB
evaporator superheat: 5K
General:
condenser sub-cool: 3K
7,5 m equivalent refrigerant piping
0 m level difference

Fan coil units


Room temperature DB/WB: 27 °C/19 °C
Cooling:
Entering/Leaving water temperature: 7 °C/12 °C
Room temperature: 20 °C
Heating:
Entering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)

Applied Systems Price list 2015-201633

AS_RS&MNE.indd 33 30.4.2015 г. 15:12:40 ч.


Notes

34

AS_RS&MNE.indd 34 30.4.2015 г. 15:12:40 ч.


Commercial terms and conditions
I. GENERAL 3. Before having paid the purchase price of an item, the customer may resell that item only if he
Our deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, simultaneously informs the second buyer (end customer) that the resale proceeds have previously been
even if the customer provides otherwise. The ordering party’s counter-confirmations in reliance on his assigned.
commercial terms and conditions or his terms and conditions of purchase apply only if they are consistent 4. The customer may collect the assigned claims as long as he fulfils his payment obligations towards us
with these terms and conditions of delivery. Acceptance of the goods is in any event deemed to constitute according to the terms of the contract. The customer may not otherwise dispose of the conditional
an acknowledgment of our terms and conditions of sale and delivery. Any deviating modifications and goods (e.g.: transfer of property by way of security, pledging).
amendments require our express consent and must be made in writing to be legally valid. Our commercial 5. The customer must immediately inform us of any attachment or other impairment of the conditional
terms and conditions can be found at www.daikin-ce.com. goods and/or the assigned claims and explain to the third party that we have retained title to those
goods. Any related cost will be borne by the customer.
II. OFFER
Our offers are without engagement and non-binding. Any information about dimensions, weights, technical VIII. WARRANTY AND LIABILITY
data, quantities and delivery times is non-binding. A. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the
absence of warranted qualities as follows:
III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE 1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date (delivery to
1. Orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order the forwarding agent). This does not affect the applicability of Section 924 of the Austrian Civil Code.
not until after we have confirmed in writing or actually executed that order. Any arrangement and 2. The customer may assert a warranty claim only if the equipment is both installed and put into
agreement reached verbally and by phone must be confirmed in writing. operation by Daikin or a company trained by Daikin according to the Daikin installation instructions
2. We reserve the right to rescind the contract even after having accepted an order if information we have and regularly maintained according to the Daikin service notes. Refrigerating machines featuring screw-
obtained about the customer’s liquidity in the meantime suggests that the customer will not be able to type compressors include a 12-month warranty claim only if the machine was put into operation by
pay for the entire or for part of the order. Daikin itself. In case of products designated “J&E Hall International for Daikin” the customer may assert
3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, an 18-month warranty claim. For “Rotex” branded products generally a 24-month warranty period is valid
e.g. in respect of its type and design, to the extent the customer can be reasonably expected to accept except for following variations: 10 years for underfloor heating pipes and system plates, VA-piping and
such changes and improvements in consideration of our interests (e.g. delivery of an equivalent or more variosafe oil storage tanks. 5 years for solar panels, variosystem and highcube oil tanks and variocistern
sophisticated device). Such changes and improvements are deemed approved in advance. rainwater tanks. 3 years for HPSU heat pump solar unit and hot water storage tanks HYC, SCS and SC.
4. The customer’s cancellation or change of an entire or of part of an order requires our written consent 3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or
and entitles us to charge the customer - in addition to the services already provided and costs accrued components. The customer may not assert other warranty or guarantee claims whatsoever. Labour cost,
- a (cancellation) fee equal to 20  % of the order value and at least €  250. For certain product travel times or other costs will not be reimbursed.
groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at 4. No warranty and/or liability is accepted, unless the customer reports visible defects by giving written
www.daikin-ce.com. notice within 3 working days of delivery and other defects without delay after these have been
discovered.
IV. PRICES AND TERMS OF PAYMENT 5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been
1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We caused by inadequate or improper use or treatment, failure to observe operating conditions or
reserve the right to change prices also during a year. maintenance guideless, excessive use or inadequate operating facilities or substitute materials.
2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, 6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we
including packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back are released from any warranty claims and damages. If the customer continues to use defective goods,
packaging and packing material. we warrant and/or are liable only for the original defect. We will not reimburse any cost of repairs which
3. We will not accept any objections to invoices which are received more than two weeks after receipt of an are carried out without our express prior consent. We disclaim any liability for the consequences of such
invoice. Unless otherwise indicated, invoices are due net 30 days from the invoice date; the payment date repairs.
is the date on which a payment is received by us. In case of late payment, we will charge default interest 7. The warranty period for spare parts and other improvements is 6 months of delivery (delivery to the
at a rate of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, forwarding agent).
including, without limitation, dunning and collection charges. 8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired
4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in components.
default in respect of only one instalment. 9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. The
5. We may make deliveries dependent on advance payment. customer has no right to withhold payments, even if he gave justified notice of defects.
6. The customer may not withhold or set off payments in reliance on warranty or other claims. 10. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims
we may assert against the supplier of the third-party product. The customer may not assert any other
V. DELIVERY TIME warranty claims and may particularly not claim a price reduction.
1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet
indicated deadlines. The customer has no right to insist on compliance with a certain delivery time. As a B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any
consequence, delays in delivery will not entail any claims for damages and do not entitle the customer liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to
to rescind the contract. The same holds true if delivery deadlines are not met due to force majeure, strike wrong deliveries) and financial loss, lost profit, unachieved savings, loss of interest and any damage suffered
or other events outside our control. from third-party claims against the customer, unless the foregoing is attributable to our intent or gross negli-
2. We will not accept penalty claims asserted by the customer under any circumstances. gence. If damage is attributable to the defective condition of goods delivered by us, we are liable only to the
3. Partial deliveries are permitted. extent the producer or upstream supplier is liable to us. Our liability does in any case not exceed the invoice
4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment value of the incriminated goods.
of the earlier delivery and is not required to pay to the ordering party any damages in this respect.
IX. RETURNED GOODS
VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE 1. Goods can be returned and exchanged only upon our express and written consent. We accept returned
1. Unless otherwise agreed, deliveries are made CIP (Incoterms 2010) to the named destination goods only with a minimum net value of € 100.00 and a maximum net value of € 50,000.00 and only
2. In principle, delivery CIP covers only minimum transport insurance. Additional transport insurance will provided that those goods are not damaged, have not been used, are in original packaging and are fit for
be purchased only if explicitly requested by customer and subject to a separate agreement and at the resale. In particular, returns of already installed units (including chillers) and returns of any made to order
customer’s cost and expense. units as well as spare parts are not permitted.
3. The customer must immediately check deliverables received by him or directly by his customers for any 2. The customer shall complete the “Request for Goods Return”-form (available at the DENV Extranet,
transport damage, and he must record any damage to the packaging or the device in the delivery note http:\\extranet.daikineurope.com) and send it to us to the fax number or email address provided by us
and shall refuse delivery towards the forwarding agent. If the customer finds out only later that goods within 10 calendar days after delivery, otherwise we will not accept the return.
are damaged, the customer shall report any such damage to us, immediately, in no case later than three 3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.
working days after delivery; otherwise, any insurance claim may expire. 4. In every case of a return, a maximum of 80% of the net price charged by us to the customer will
4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods be credited. All standard returns will be subject to a restocking / administration charge of 20 % of the
as delivered or may otherwise dispose of them @ setting a time limit. If we otherwise dispose of the net price.
goods, the delivery time will recommence on the day we receive the customer’s written request calling 5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph
for delivery of the goods. 1. above), we may refuse the returns and have them returned back to the customer at the customer’s
5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, risk and costs. Alternatively, we may charge a higher restocking / administration fee than the above
any storage costs. mentioned 20%.
6. Any credit notes whatsoever will exclusively be set off against future deliveries.
VII. RESERVATION OF TITLE
1. We will retain title to goods delivered pending full payment of all claims arising from our business X. PLACE OF JURISDICTION, APPLICABLE LAW
relationship with the customer, even if the purchase price for specifically designated claims was paid. If 1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts
our conditional goods are processed, we will acquire title to the new item without consideration. If the in Vienna.
goods delivered by us are mixed, processed or combined with other items, the customer hereby assigns 2. All contracts concluded by us and all disputes arising in connection with those contracts shall be
to us in proportion of the value of our invoices an ownership or co-ownership right of the combined or governed by and construed in accordance with Austrian law without giving effect to its conflict of law
new item, both in respect of the interim and the final products. rules and the UN Sales Convention.
2. The customer may resell goods delivered by us and the items created by processing, mixing or combining
these only in the ordinary course of business. The customer hereby assigns to us any claims arising from XI. SEVERABILITY
such resale or from any other legal ground toward third parties, including, ancillary rights, in order to Should any term of these commercial terms and conditions or of the contract concluded between us and
secure our - future - claims that may arise from our business relationship. The customer must record the the customer be invalid or ineffective, this shall not affect the remaining terms hereof or thereof. Invalid
assignment of these claims in his books not later than when the goods are resold. terms shall be replaced by lawful terms which closest reflect the parties’ intent.

The Daikin Commercial terms and conditions are also available in the internet at www.daikin-ce.com

Campus 21, Europaring F12/402 · A-2345 Brunn am Gebirge, Austria


phone +43 2236 32557, fax +43 2236 32557-900, office@daikin-ce.com, www.daikin-ce.com

Applied Systems Price list 2015-201635

AS_RS&MNE.indd 35 30.4.2015 г. 15:12:41 ч.


Fact: R-22 has been banned in Europe*
If your equipment is more than 15 years old, it probably still uses R-22
refrigerant. After 31st December 2014 repairs to R-22 systems will be
prohibited, possibly resulting in unexpected downtime. Keep your
business running at all times with Daikin replacement technology.

Controller box
upgrade - Softstarter
- Inverter

Compressor
upgrade

* EU directive: Regulation (EC) No.2037/2000

DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH


campus 21, Europaring F12/402, A–2345 Brunn am Gebirge · Tel.: +43 / 2236 / 32557 · Fax: +43 / 2236 / 32557-910 · e-mail: office@daikin.at · www.daikin-ce.com

The present publication is drawn up by way of information only and does not
Daikin products are distributed by: constitute an offer binding upon Daikin Europe N.V. / Daikin Central Europe
HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH have
compiled the content of this publication to the best of their knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability
or fitness for particular purpose of its content and the products and services
presented therein. Specifications are subject to change without prior notice. Daikin
Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability
for any direct or indirect damage, in the broadest sense, arising from or related
to the use and/or interpretation of this publication. All content is copyrighted by
Daikin Europe N.V.

DACE Applied Systems Pricelist for Serbia & Montenegro 2015-2016.


Prepared by RAITZ-2, Bulgaria.

AS_RS&MNE.indd 36 30.4.2015 г. 15:12:43 ч.

You might also like