Professional Documents
Culture Documents
www.huawei.com
Handover
2G/3G Interoperability
Power Control
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Traffic Share Solution
I. In case of GSM900 and DCS1800 co-location, the GSM900 has strong signal
strength but we can use the idle parameter setting and handover to control the
traffic and achieve the balanced traffic between GSM900 and DCS1800
II. In case of 2G and 3G co-location, we can use the idle parameter setting and
handover to control the traffic and achieve the balanced traffic between 2G
and 3G
For the areas covered by both the GSM network and the UMTS
network,2G/3G interoperability can be performed to achieve traffic balance
between the GSM and UMTS.
I.Only suggest to active the cell reselection from 2G to 3G.
II.Both cell reselection and handover are suggested from 3G to 2G.
① 2G Coverage
②
3G/2G Coverage
Handover
2G/3G Interoperability
Power Control
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Idle Mode
GSM900
GSM 900 GSM 900 GSM 900 Layer 3
Cell
2 4
Actual distance between MS &
MAX TA(bit period(1 bit=0.55km)) 62 33
BTS Repeater site Repeater site
value TBD value TBD
Rural,5
Suburban 5 15 15
RXLEV_ACCESS_MIN RxLevel Acces Min Others 8 (follow (follow existing 20
(follow existing existing value) value)
value)
Radio Link Timeout (FR & EFR) RLT 32 28 36 28
Radio Link Timeout (AMR FR) AFRDSBLCNT 48 48 48 48
Layer of the Cell Layer of the Cell 3 2 1 1
Cell Priority Cell Priority 1 1 1 1
CRO Cell Reselection Offset 0 (0dB) 12 (24dB) 18(36dB) 15 (30dB)
TO Temporary Offset 0 (0dB) 0 (0dB) 4 (40dB) 4 (40dB)
PT Penalty Time 0 (20 second) 0 (20 second) 1 (40 second) 0 (20 second)
Handover
2G/3G Interoperability
Power Control
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Handover
MS Goes into
Dedicated Mode
Bad Quality HO
• Edge Handover
Handover
RX_Lev Triggering
Time
P/N
• Layer Handover
• PBGT Handover
Handover
Triggering
Path Loss
(dB) P: Watch
Time
PBGT 5 N: Valid
HO Time
Threshold
Time
P/N
126-
126dB119=7dB>5dB
119dB
• Parameter suggested
Edge HO UL RX_LEV Threshold Edge HO uplink RX Level threshold -98 dBm -94 dBm -94 dBm -94 dBm
Edge HO DL RX_LEV Threshold Edge HO downlink RX Level threshold -94 dBm -90 dBm -90 dBm -90 dBm
Inter-layer HO Threshold Inter-layer HO Threshold -75 dBm -85 dBm -85 dBm -85 dBm
TALIMIT TA Threshold 62 33 2 4
Handover
2G/3G Interoperability
Power Control
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
2G/3G Interoperability
Cell Reselection Flow(2G->3G)
Start
Start
Inter-RAT
Inter-RATCell
CellReselection
ReselectionEnable=Yes
Enable=Yes
RLA_C>level
RLA_C>levelthreshold
thresholdfor
forsearching
searching3G
3Gcell
cell
11 .RSCP
.RSCP >>RLA_C+
RLA_C+FDD_Q_offset
FDD_Q_offset
2.2. Ec/NO FDD_Q_min––FDD_Qmin_Offset
Ec/NO>>FDD_Q_min FDD_Qmin_Offset
3.3. RSCP
RSCP >> FDD_RSCP_MIN
FDD_RSCP_MIN
Ec/No>FDD_Qmin
Ec/No>FDD_Qmin &last
&lastmore
morethan
than5s5s
Above conditionsare
Aboveconditions aremet
metfor
forfive
fiveconsecutive
consecutive
seconds
seconds
End
End
• Parameter suggested
PARAMETER
PROPOSED VALUES
Abbreviated Name Parameter Name
Handover
2G/3G Interoperability
Power Control
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Power Control
• Huawei III Power Control
Step Calculation:
PROPOSED PROPOSED
Parameter Name (UL) Parameter Name (DL)
VALUES VALUES
ULRexLevHighThred 18 (Rxlev > -92dBm) DLRexLevHighThred 25 (Rxlev > -85dBm)
ULRexLevLowThred 18 (Rxlev < -92dBm) DLRexLevLowthred 25 (Rxlev < -85dBm)
ULFSRexQualHighThred 16 (C/I >16dB) DLFSRexQualHighThred 16 (C/I >16dB)
ULFSRexQualLowThred 16 (C/I <16dB) DLFSRexQualLowThred 16 (C/I <16dB)
ULHSRexQualHighThred 18 (C/I >18dB) DLHSRexQualHighThred 18 (C/I >18dB)
ULHSRexQualLowThred 18 (C/I <18dB) DLHSRexQualLowThred 18 (C/I <18dB)
ULAFSRexQualHighThred 14 (C/I >14dB) DLAFSRexQualHighThred 14 (C/I >14dB)
ULAFSRexQualLowThred 14 (C/I <14dB) DLAFSRexQualLowThred 14 (C/I <14dB)
ULAHSRexQualHighThred 16 (C/I >16dB) DLAHSRexQualHighThred 16 (C/I >16dB)
ULAHSRexQualLowThred 16 (C/I <16dB) DLAHSRexQualLowThred 16 (C/I <16dB)
ULMAXDOWNSTEP 6 dB DLMAXDOWNSTEP 4 dB
ULMAXUPSTEP 8 dB DLMAXUPSTEP 8 dB
ULREXLEVADJFCTR 3 DLREXLEVADJFCTR 3
ULREXQUALADJFCTR 4 DLREXQUALADJFCTR 4
DLRXLEVPROTECTFACTOR 10 ULRXLEVPROTECTFACTOR 10
DLRXQUALPROTECTFACTOR 60 ULRXQUALPROTECTFACTOR 60