Tabla de Datos Parcialmente Sumergida

Masa [g] d [mm] ±0.5 Masa [Kg] d ±0.0005 [m]


70.0 54.0 0.0700 0.0540
90.0 60.0 0.0900 0.0600
110.0 68.0 0.1100 0.0680
130.0 74.0 0.1300 0.0740

Tabla de Datos Totalmente Sumergida

Masa [g] d [mm] ±0.5 Masa [Kg] d ±0.0005 [m]


270.0 110.0 0.0700 0.0110
290.0 116.0 0.0900 0.0116
350.0 130.0 0.1100 0.0130
370.0 135.0 0.1300 0.0135

Cálculo para el Empuje Hidrostático -Parcialmente Sumergida-


Utilizaremos la ecuación para determinar el Empuje Hidrostático (ec.)

𝐾𝑔
𝜌𝑔𝐵𝑑2 (1000 ⁄ 3 )(9.81 𝑚⁄ 2 ) (75.30𝑥10−3 )(0.0540)2
𝑚 𝑠
𝐹= = = 1.08 𝑁
2 2
𝐾𝑔
𝜌𝑔𝐵𝑑2 (1000 ⁄ 3 )(9.81 𝑚⁄ 2 ) (75.30𝑥10−3 )(0.0600)2
𝑚 𝑠
𝐹= = = 1.33 𝑁
2 2
𝐾𝑔
𝜌𝑔𝐵𝑑2 (1000 ⁄ 3 )(9.81 𝑚⁄ 2 ) (75.30𝑥10−3 )(0.0680)2
𝑚 𝑠
𝐹= = = 1.71 𝑁
2 2
𝐾𝑔
𝜌𝑔𝐵𝑑2 (1000 ⁄ 3 )(9.81 𝑚⁄ 2 ) (75.30𝑥10−3 )(0.0740)2
𝑚 𝑠
𝐹= = = 2.02 𝑁
2 2

Cálculo para h’’exp -Parcialmente Sumergida-


Posición Experimental del Centro de Presión
" 2𝑚𝐿 2(0.070 𝐾𝑔)(0.27520 𝑚)
ℎ𝑒𝑥𝑝 = 𝜌𝐵𝑑2 = 𝐾𝑔 = 175.47 [𝑚𝑚]
(1000 ⁄ 3 ) (0.07530 𝑚 )(0.05402 𝑚2 )
𝑚

" 2𝑚𝐿 2(0.090 𝐾𝑔)(0.27520 𝑚)


ℎ𝑒𝑥𝑝 = = 𝐾𝑔 = 182.74 [𝑚𝑚]
𝜌𝐵𝑑2 (1000 ⁄ 3 ) (0.07530 𝑚 )(0.06002 𝑚2 )
𝑚

" 2𝑚𝐿 2(0.110 𝐾𝑔)(0.27520 𝑚)


ℎ𝑒𝑥𝑝 = 𝜌𝐵𝑑2 = 𝐾𝑔 = 173.88 [𝑚𝑚]
(1000 ⁄ 3 ) (0.07530 𝑚 )(0.06802 𝑚2 )
𝑚

" 2𝑚𝐿 2(0.130 𝐾𝑔)(0.27520 𝑚)


ℎ𝑒𝑥𝑝 = 𝜌𝐵𝑑2 = 𝐾𝑔 = 173.53 [𝑚𝑚]
(1000 ⁄ 3 ) (0.07530 𝑚 )(0.07402 𝑚2 )
𝑚
Cálculo para h’’exp -Parcialmente Sumergida-
Posición Teórica del Centro de Presión
" 𝑑
ℎ𝑡𝑒𝑜 =𝐻−3
" 54.0 𝑚𝑚
ℎ𝑡𝑒𝑜 = 199.82 𝑚𝑚 − = 181.82 𝑚𝑚
3
" 60.0 𝑚𝑚
ℎ𝑡𝑒𝑜 = 199.82 𝑚𝑚 − = 179,82 𝑚𝑚
3
" 68.0 𝑚𝑚
ℎ𝑡𝑒𝑜 = 199.82 𝑚𝑚 − = 177.15 𝑚𝑚
3
" 74.0 𝑚𝑚
ℎ𝑡𝑒𝑜 = 199.82 𝑚𝑚 − = 175.15 𝑚𝑚
3

Cálculo para el Empuje Hidrostático -Totalmente Sumergida-


Utilizaremos la ecuación para determinar el Empuje Hidrostático (ec.)
𝐷
𝐹 = 𝜌𝑔𝐵𝐷 (𝑑 − 2 )
(100𝑥10 −3
𝐾𝑔⁄ 𝑚 𝑚)
𝐹 = (1000 (0.07530 𝑚 )(100𝑥10−3 𝑚) (110𝑥10−3 −
𝑚3 ) (9.81 ⁄𝑠 2 ) 2
)

= 𝟒. 𝟒𝟑 𝐍
(100𝑥10 −3
𝐾𝑔⁄ 𝑚 𝑚)
𝐹 = (1000 (0.07530 𝑚 )(100𝑥10−3 𝑚) (116𝑥10−3 −
𝑚3 ) (9.81 ⁄𝑠 2 ) 2
)

= 𝟒. 𝟖𝟖𝑵
(100𝑥10 −3
𝐾𝑔⁄ 𝑚 𝑚)
𝐹 = (1000 (0.07530 𝑚 )(100𝑥10−3 𝑚) (130𝑥10−3 −
𝑚3 ) (9.81 ⁄𝑠 2 ) 2
)

= 𝟓. 𝟗𝟏 𝑵
(100𝑥10 −3
𝐾𝑔⁄ 𝑚 𝑚)
𝐹 = (1000 (0.07530 𝑚 )(100𝑥10−3 𝑚) (135𝑥10−3 −
𝑚3 ) (9.81 ⁄𝑠 2 ) 2
)

= 𝟔. 𝟐𝟖 𝑵

Cálculo para h’’exp -Totalmente Sumergida-


Posición Experimental del Centro de Presión

" 𝑚𝐿
ℎ𝑒𝑥𝑝 = 𝐷
𝜌𝑔𝐵𝐷(𝑑− )
2

"
(0.270 𝑘𝑔)(0.27520 𝑚 )
ℎ𝑒𝑥𝑝 =
(100𝑥10−3 𝑚)
(1000 𝐾𝑔⁄𝑚3 ) (9.81 𝑚⁄𝑠2 )(0.07530 𝑚 )(100𝑥10−3 𝑚) (110𝑥10−3 − )
2
= 164 𝑚𝑚

"
(0.290 𝑘𝑔)(0.27520 𝑚 )
ℎ𝑒𝑥𝑝 =
(100𝑥10−3 𝑚)
(1000 𝐾𝑔⁄𝑚3 ) (9.81 𝑚⁄𝑠2 )(0.07530 𝑚 )(100𝑥10−3 𝑚) (116𝑥10−3 − )
2
= 161 𝑚𝑚

"
(0.350 𝑘𝑔)(0.27520 𝑚 )
ℎ𝑒𝑥𝑝 =
(100𝑥10−3 𝑚)
(1000 𝐾𝑔⁄𝑚3 ) (9.81 𝑚⁄𝑠2 )(0.07530 𝑚 )(100𝑥10−3 𝑚) (130𝑥10−3 − 2
)
= 160 𝑚𝑚
"
(0.370 𝑘𝑔)(0.27520 𝑚 )
ℎ𝑒𝑥𝑝 =
(100𝑥10−3 𝑚)
(1000 𝐾𝑔⁄𝑚3 ) (9.81 𝑚⁄𝑠2 )(0.07530 𝑚 )(100𝑥10−3 𝑚) (135𝑥10−3 − )
2
= 159 𝑚𝑚

Cálculo para h’’exp -Totalmente Sumergida-


Posición Teórica del Centro de Presión

𝐷2 𝐷
+ (𝑑 − )2
´´
ℎ𝑡𝑒𝑜 = 12 2 +𝐻−𝑑
𝐷
𝑑−2

(100𝑥10−3 )2 −3 100𝑥10−3 2
12 + (110𝑥10 − 2 )
´´
ℎ𝑡𝑒𝑜 = −3 + 199.82𝑥10−3 − 110𝑥10−3
100𝑥10
110𝑥10−3 − 2
= 𝟏𝟔𝟑. 𝟕𝟏 𝒎𝒎

(100𝑥10−3 )2 −3 100𝑥10−3 2
12 + (116𝑥10 − 2 )
´´
ℎ𝑡𝑒𝑜 = −3 + 199.82𝑥10−3 − 116𝑥10−3
100𝑥10
116𝑥10−3 −
2
= 𝟏𝟔𝟐, 𝟒𝟓 𝒎𝒎
(100𝑥10−3 )2 −3 100𝑥10−3 2
12 + (130𝑥10 − 2 )
´´
ℎ𝑡𝑒𝑜 = −3 + 199.82𝑥10−3 − 130𝑥10−3
100𝑥10
130𝑥10−3 −
2
= 𝟏𝟔𝟎. 𝟐𝟒 𝒎𝒎
(100𝑥10−3 )2 −3 100𝑥10−3 2
12 + (135𝑥10 − 2 )
´´
ℎ𝑡𝑒𝑜 = + 199.82𝑥10−3 − 135𝑥10−3
−3 100𝑥10−3
135𝑥10 − 2
= 𝟏𝟓𝟗. 𝟔𝟐 𝒎𝒎

CALCULO DE LAS INCERTIDUMBRES

Empuje Hidrostático -Parcialmente Sumergida

𝜌𝑔𝐵𝑑2 𝜌𝑔𝑑2 2 𝜌𝑔𝐵2𝑑 2


𝐹= 𝛿𝐹 = √| (𝛿𝐵)| + | (𝛿𝑑)|
2 2 2

2 2
(1000)(9.81)(0.0540)2 (1000)(9.8)(75.30𝑥10−3 )2(0.0540)
= √| (0.01𝑥10−3 )| + | (0.5𝑥10−3 )|
2 2
= 0.02
2 2
(1000)(9.81)(0.0600)2 (1000)(9.8)(75.30𝑥10−3 )2(0.0600)
= √| (0.01𝑥10−3 )| + | (0.5𝑥10−3 )|
2 2
= 0.02

2 2
(1000)(9.81)(0.0680)2 (1000)(9.8)(75.30𝑥10−3 )2(0.0680)
= √| (0.01𝑥10−3 )| + | (0.5𝑥10−3 )|
2 2
= 0.03

2 2
(1000)(9.81)(0.0740)2 (1000)(9.8)(75.30𝑥10−3 )2(0.0740)
= √| (0.01𝑥10−3 )| + | (0.5𝑥10−3 )|
2 2
= 0.03
Cálculo para δh’’exp -Parcialmente Sumergida-
Posición Experimental del Centro de Presión

2 2 2
"
2𝑚 2𝑚𝐿 −2 4𝑚𝐿 −3
𝛿ℎ𝑒𝑥𝑝 = √| 𝛿𝐿| + | 2 (𝐵 )𝛿𝐵| + | (𝑑 )𝛿𝑑|
𝜌𝐵𝑑2 𝜌𝑑 𝜌𝐵

2 2
2(0.070) 2(0.070)(0.27520)
= √| (0.01𝑥10 −3 )| + | (0.07530−2 )(0.01𝑥10−3 )|
(1000)(0.07530)(0.0540)2 1000(0.0540)2
̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅
4(0.070)(0.27520) 2
+| −3
(0.0540 )(0.5𝑥10 −3 )| = 3.25
(1000)(0.07530)

2 2
2(0.090) 2(0.090)(0.27520)
= √| 2
(0.01𝑥10−3 )| + | (0.07530−2 )(0.01𝑥10−3 )|
(1000)(0.07530)(0.0600) 1000(0.0600)2
̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅
4(0.090)(0.27520) 2
+| −3 −3
(0.0600 )(0.5𝑥10 )| = 3.05
(1000)(0.07530)

2 2
2(0.110) 2(0.110)(0.27520)
= √| (0.01𝑥10 −3 )| + | (0.07530−2 )(0.01𝑥10−3 )|
(1000)(0.07530)(0.0680)2 1000(0.0680)2
̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅
4(0.110)(0.27520) 2
+| −3
(0.0680 )(0.5𝑥10 −3 )| = 2.56
(1000)(0.07530)
2 2
2(0.130) 2(0.130)(0.27520)
= √| 2
(0.01𝑥10−3 )| + | (0.07530−2 )(0.01𝑥10−3 )|
(1000)(0.07530)(0.0740) 1000(0.0740)2
̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅
4(0.130)(0.27520) 2
+| −3 −3
(0.0740 )(0.5𝑥10 )| = 2.35
(1000)(0.07530)

Cálculo para δh’’teórico -Parcialmente Sumergida-


Posición Teórica del Centro de Presión

𝛿𝑑 2
"
𝛿ℎ𝑡𝑒𝑜 √ 2
= |𝛿𝐻| + | |
3

2
"
0.5𝑥10−3
𝛿ℎ𝑡𝑒𝑜 = √|0.01𝑥10−3 |2 +| | = 0.2
3

Empuje Hidrostático -Parcialmente Sumergida

2
𝐷

𝛿𝐹 = |𝜌𝑔𝐷 (𝑑 − ) (𝛿𝐵)| + |𝜌𝑔𝐵𝐷(𝛿𝑑)|2 + |𝜌𝑔𝐵𝑑𝛿𝐷 − 𝜌𝑔𝐵𝐷𝛿𝐷|2
2
2
10−1
= √|(9.81𝑥102 ) (0.0540 − ) (0.01𝑥10−3 )| + +|(9.81𝑥10−7 )(75.30)(0.5)|2
2

̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅̅
|(1000(9.81)(75.30𝑥10−11 (54 − 100)|2 = 𝟎. 𝟎𝟒

Cálculo para δh’’exp -Totalmente Sumergida-


Posición Experimental del Centro de Presión

"
ℎ𝑒𝑥𝑝
2 2 2 2
𝑚𝛿𝐿 𝑚𝛿𝐿 𝑚𝐿 𝑚𝐿(𝑑 − 𝐷)
= √| | +| 𝛿𝐵| + | 𝛿𝑑| + | 𝛿𝐷|
𝐷 𝐷 𝐷 𝐷
𝜌𝑔𝐵𝐷(𝑑 − 2 ) 𝜌𝑔𝐵 −2 𝐷(𝑑 − 2 ) (𝑑 − 2 ) 𝐷(𝑑 − 2 )
Cálculo para δh’’teórico -Totalmente Sumergida-
Posición Teórica del Centro de Presión

ANEXO B RESULTADOS
Resultados para una Superficie Plana Vertical Parcialmente Sumergida
Fuerza [N] h’’exp [mm] h’’teorice [mm]
1.08 ±0.2 175.47 ±3.25 181.82 ±0.2
1.33 ±0.2 182.74 ±3.05 179.82 ±0.2
1.71±0.3 173.88 ±2.56 177.15 ±0.2
2.02±0.3 173.53 ±2.56 175.15 ±0.2
Tabla 2 Resultados Para Superficie Plana Parcialmente Sumergida

Resultados para una Superficie Plana Vertical Totalmente Sumergida


Fuerza [N] h’’exp [mm] h’’teorice [mm]
4.43 ±0.04 164 ±1 163.71 ±0.10
4.88±0.04 161 ±1 162.45 ±0.09
5.91±0.04 160 ±1 160.24 ±0.07
6.28±0.04 159 ±1 159.62 ±0.06

ANEXO C GRAFICOS

Fuerza Hidróstatica vs Profundidad de inmersión


2.20
2.02
2.00
Fuerza Hidrostática (N)

1.80 1.71

1.60
y = 0.0473x - 1.4914
1.40 1.33 R² = 0.9981

1.20 1.08
1.00
50.0 55.0 60.0 65.0 70.0 75.0 80.0
Produndidad de Inmersión (mm)

Gráfico 1 Fuerza Hidrostática [N] vs Profundidad de Inmersión [mm]


Profundidad de Centro de Presión Experimental[mm] vs Produndidad de Inmersión
[mm]
Prodfundidad de centro de Presión (mm)

190.00

185.00 182.74

180.00
175.47
173.88 173.53
175.00

170.00 y = -0,2363x + 191,52


R² = 0,2329
165.00

160.00
50.0 55.0 60.0 65.0 70.0 75.0 80.0
Produndidad de inmersión (mm)

Gráfico 2 Profundidad de Centro de Presión Exp. vs Profundidad de Inmersión

Profundidad de Centro de Presion Teórica [mm] vs


Profundidad de Inmersión
Profundidad de Centro de Presión [mm]

190.00

185.00 181.82
179.82
180.00 177.15
175.15
175.00

170.00 y = -0,3333x + 199,82


165.00 R² = 0,989
160.00
50.0 55.0 60.0 65.0 70.0 75.0 80.0
Profundidad de Inmersión [mm]

Gráfico 3 Profundidad de Centro de Presión Teórica vs Profundidad de Inmersión


Fuerza Hidróstatica [N] vs Profundidad de inmersión [mm]
6.50 6.28

Fuerza Hidrostática (N)


5.91
6.00

5.50
4.88
5.00 y = 0,0739x - 3,6935
4.43 R² = 0,95
4.50

4.00
105.00 110.00 115.00 120.00 125.00 130.00 135.00 140.00

Produndidad de Inmersión (mm)

Gráfico 4 Fuerza Hidrostática vs Profundidad de Inmersión

Profundidad de Centro de PresiónTeórica [mm] vs Profundidad


170.00
de Inmersión[mm]
Profundidad de Centro de Inmersión [mm]

168.00
166.00 163.71
164.00 162.45
162.00 160.24 159.62
160.00
158.00
y = -0,1624x + 181,43
156.00
R² = 0,9943
154.00
152.00
150.00
100.0 105.0 110.0 115.0 120.0 125.0 130.0 135.0 140.0
Produndidad de Inmersión [mm]
Gráfico 5 Profundidad de Centro de Presión Teórica vs Profundidad de Inmersión

Profundidad de Centro de Presión Experimental [mm] vs


Pro¡fundidad de Centro de Presión

Profundida de Inmersión [mm]


170
168
166
164
164
162
161 160 159
[mm]

160
158
156
154 y = -0,1772x + 182,76
152 R² = 0,7572
150
100.0 105.0 110.0 115.0 120.0 125.0 130.0 135.0 140.0
Profundidad de Inmersión [mm]

Gráfico 6 Profundidad de Centro de Presión Teórica vs Profundidad de Inmersión