Electric Circuits III: Worksheet No. 1

Three phase voltage


1) In a balanced three phase voltage system, the phase voltages are 120 volts, what is the line to line voltage? 170 volts
2) The three phase rural distribution system has a phase to neutral voltage 7,960 volts, what is the line to line voltage?
3) The wye connected three phase ABC voltage source has VCN=240∠-240°. Find the line to line voltage VAB. 415.69∠30°
4) A balanced three phase wye connected source has using negative phase sequence, VAB=381∠60°. Determine VCN.
5) If VBC=240∠45°, find VAN, VBN, VCN. 138.56∠135°, 138.56∠15°,138.56∠-105°
6) If a balanced y connected source VBN=110∠60°, find VAB, VBC, VCA.

Wye-Wye, Wye-delta system


7) The magnitude of the phase voltage of a balanced three phase Y connected source is 125 V. The source is connected to a
balanced Y connected load by a distribution line that has an impedance of 0.1 + 𝑗0.8𝛺/𝜙. The load impedance is 19.9 +
𝑗14.2𝛺/𝜙. The phase sequence of the source is ACB. Use the a-phase voltage of the source as the reference. Find a) the line
currents, b) the three line voltages at the source c) the three phase voltages at the load, and d) the three line voltages at
the load.
a) 5∠-36.87°A, 5∠83.13°A, 5∠-156.87° A
b) 216.51∠-30°V, 216.51∠90°V, 216.51∠-150°V
c) 122.23∠-1.36°V, 122.23∠118.64°V, 122.23∠-121.36°V
d) 211.72∠-31.36°V, 211.72∠88.64°V, 211.72∠-151.36°V
8) A balanced positive phase sequence wye connected source with E AN=120∠0°V supplies power to a balanced wye connected
load. If the per phase load impedance is 20 + 𝑗20𝛺 and the per phase impedance of the distribution line is1 + 𝑗2𝛺, find a)
the line currents and b) the phase voltages at the load.
9) A balanced three-phase wye connected generator with positive sequence has an impedance of 0.2 + 𝑗0.5𝛺/𝜙 and an
internal voltage of 120V/ 𝜙. The generator feeds a balanced three phase wye connected load having an impedance of 39 +
𝑗28𝛺/𝜙. The impedance of the line connecting the generator to the load is 0.8 + 𝑗1.5𝛺/𝜙. The a-phase internal voltage of
the generator is specified as the reference phasor. a) Calculate the line currents, b) Calculate the three phase voltage at the
load, c) Calculate the line voltage at the load
a) 2.4∠-36.87°A, 2.4∠-156.87°A, 2.4∠83.13°A
b) 115.22∠-1.19°V, 115.22∠-121.19°V, 115.22∠118.81°V
c) 199.58∠28.821°V, 119.58∠-91.19°V, 199.58∠148.81°V
10) The phase voltage at the terminals of a balanced three-phase wye connected load is 2400 V. The load has an impedance of
16 + 𝑗12𝛺/𝜙 and is fed from a line having an impedance of 0.1 + 𝑗0.8𝛺/𝜙. The wye connected source at the sending end
of the line has a-phase sequence of acb and an internal impedance of 0.02 + 𝑗0.16𝛺/𝜙. Use the a-phase voltage at the
load as the reference and calculate a) the line currents, b) line voltages at the load, c) the phase voltage at the load.
11) A balanced negative sequence wye-delta system has a per phase distribution line impedance of 1 + 𝑗0.5𝛺 and a per phase
load impedance of 20 + 𝑗10𝛺. If EAN=120∠0° V, find a) line currents and b) phase voltage at the load
a) 14∠-26.57°A, 14∠93.43°A, 14∠-146.57°A
b) 180.7∠-30°V, 180.7∠90°V, 180.7∠-150°V
12) A balanced delta connected load with a phase impedance of 50 − 𝑗20𝛺 is powered by a balanced positive phase sequence
wye connected source via a distribution line having a per phase impedance of 0.5 + 𝑗1𝛺. If VAB=208∠0°, find a) line currents
and b) line voltages at the source end of the line (EAB, EBC, ECA).
a) Ia=6.690∠-8.2°A, IB=6.69∠-128.2°, IC=6.69∠111.8°
b) EAB=209.47∠3.53°, EBC=209.47∠-116.47°, ECA=209.47∠123.533°
13) A balanced Y-connected load having an impedance of 12 + 𝑗5𝛺/𝜙 is connected in parallel with a balanced delta
connected load having an impedance of 24 − 𝑗30Ω/ 𝜙. The parallel loads are fed from a line having an
impedance of 1 + 𝑗1𝛺/𝜙. The magnitude of the line to line voltage balanced three phase source is 207.85∠
30°V. Determine a) the line currents, b) the phase voltage at the load c) the line voltage at both loads.
a) 6.04∠37.3°A, 6.04∠-82.7°A, 6.4∠157.3°A
b) 77.3∠-14.04°V, 77.3∠-134.04°V, 77.3∠105.96°V
c) 133.88∠15.96°V,133.88∠-104.04°V,133.88∠135.96°V