You are on page 1of 6

DESIGN OF SLAB AS PER IS:456-2000

latest 28/4/06

BUILDING NAME DPC SLAB S2


SHORT SPAN (mt) Lx 3.20 CONCRETE GRADE M- 20
LONG SPAN (mt) Ly 8.00 STEEL GRADE Fe - 415
SLAB THICKNESS (mm) - D 125 LOAD FACTOR ( L.S.D ) 1.2
LOADS
DEAD LOAD ( KN/Sq.mt ) 3.13 WIDTH OF SLAB ( mm ) B 1000
FINISHES ( KN/Sq.mt ) 2.50 CLEAR COVER ( mm ) 20
LIVE LOAD ( KN/Sq.mt ) 2.00 DIA OF MAIN STEEL ( mm ) 8
DIA OF DIST. STEEL ( mm ) 8
TOTAL LOAD(KN/Sq.mt) 7.63 EFFECTIVE THICKNESS ( mm ) -d 101

B.M COEFFICIENTS:
EDGE CONDITION : CASE 3 ONE LONG EDGE DISCONTINUOUS
AVERAGE MAXIMUM B.M w*Lx*Lx/10
RATIO OF LONG/SHORT SPAN 2.50 ONE-WAY SLAB
FACTORED B.M (KN.M) (KN.mt)
( -VE ) COEFFT. ALONG Lx 0.000 ( -VE ) B.M ALONG Lx 0.00
( +VE ) COEFFT. ALONG Lx 0.100 ( +VE ) B.M ALONG Lx 9.37
( - VE ) COEFFT. ALONG Ly 0.000 ( - VE ) B.M ALONG Ly 0.00
( +VE ) COEFFT. ALONG Ly 0.000 ( +VE ) B.M ALONG Ly 0.00
AREA OF STEEL REQUIRED ( Sq.mm ) SPACING OF STEEL REQUIRED ( mm )
MAX. SPACING AS PER IS-456 303
MINIMUM STEEL AS PER IS-456 150 SPACING OF MINIMUM STEEL 335
( -VE ) STEEL ALONG Lx 150 ( -VE ) STEEL ALONG Lx 303
( +VE ) STEEL ALONG Lx 272 ( +VE ) STEEL ALONG Lx 185
( -VE ) STEEL ALONG Ly 150 ( -VE ) STEEL ALONG Ly 303
( +VE ) STEEL ALONG Ly 150 ( +VE ) STEEL ALONG Ly 303

AREA OF STEEL PROVIDED ( Sq.mm ) SPACING OF STEEL PROVIDED ( mm C/C )

( -VE ) STEEL ALONG Lx 335 ( -VE ) STEEL ALONG Lx 150


( +VE ) STEEL ALONG Lx 335 ( +VE ) STEEL ALONG Lx 150
( -VE ) STEEL ALONG Ly 335 ( -VE ) STEEL ALONG Ly 150
( +VE ) STEEL ALONG Ly 335 ( +VE ) STEEL ALONG Ly 150

CHECK FOR DEFLECTION:

BASIC L/d RATIO 26


Provided.(+) ve pt.(IN SHORTER 0.33 THEORITICAL MODIFICATION FACTOR AS
SPAN) PER SP-24 1.45
Reqd.(+) ve pt.(IN SHORTER Permissible L/d ratio
SPAN) 0.27 39.71
EFF.DEPTH REQUIRED - d (mm) 81 EFF. DEPTH PROVIDED - d ( mm ) 101
HENCE DESIGN OF SLAB IS SAFE
cont..SLAB S2

SUMMARY OF SLAB :
. SPACING OF STEEL PROVIDED (c/c) ( mm )
GRADE OF CONCRETE M 20 ( -VE ) STEEL ALONG SHORT SPAN 150
GRADE OF STEEL Fe 415 ( +VE ) STEEL ALONG SHORT SPAN 150
THICKNESS OF SLAB ( mm ) 125 ( -VE ) STEEL ALONG LONG SPAN 150
DIA OF MAIN STEEL ( mm ) 8 ( +VE ) STEEL ALONG LONG SPAN 150
DIA OF DIST STEEL ( mm ) 8 No. OF EXTRA BARS OVER SUPPORTS 2

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

LX

LY

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

SLAB S2
DESIGN OF SLAB AS PER IS:456-2000
latest 28/4/06

BUILDING NAME DPC SLAB S1


SHORT SPAN (mt) Lx 4.69 CONCRETE GRADE M- 20
LONG SPAN (mt) Ly 6.06 STEEL GRADE Fe - 415
SLAB THICKNESS (mm) - D 150 LOAD FACTOR ( L.S.D ) 1.5
LOADS
DEAD LOAD ( KN/Sq.mt ) 3.75 WIDTH OF SLAB ( mm ) B 1000
FINISHES ( KN/Sq.mt ) 1.00 CLEAR COVER ( mm ) 20
LIVE LOAD ( KN/Sq.mt ) 10.00 DIA OF MAIN STEEL ( mm ) 10
DIA OF DIST. STEEL ( mm ) 8
TOTAL LOAD(KN/Sq.mt) 14.75 EFFECTIVE THICKNESS ( mm ) -d 125

B.M COEFFICIENTS:
EDGE CONDITION : CASE 1 INTERIOR PANEL
B.M. COEFFICIENTS AS PER TABLE 26 OF IS:456-2000
RATIO OF LONG/SHORT SPAN 1.29 TWO-WAY SLAB
FACTORED B.M (KN.M) (KN.mt)
( -VE ) COEFFT. ALONG Lx 0.046 ( -VE ) B.M ALONG Lx 22.33
( +VE ) COEFFT. ALONG Lx 0.035 ( +VE ) B.M ALONG Lx 16.91
( - VE ) COEFFT. ALONG Ly 0.033 ( - VE ) B.M ALONG Ly 16.18
( +VE ) COEFFT. ALONG Ly 0.025 ( +VE ) B.M ALONG Ly 12.17
AREA OF STEEL REQUIRED ( Sq.mm ) SPACING OF STEEL REQUIRED ( mm )
MAX. SPACING AS PER IS-456 375
MINIMUM STEEL AS PER IS-456 180 SPACING OF MINIMUM STEEL 437
( -VE ) STEEL ALONG Lx 544 ( -VE ) STEEL ALONG Lx 144
( +VE ) STEEL ALONG Lx 402 ( +VE ) STEEL ALONG Lx 196
( -VE ) STEEL ALONG Ly 383 ( -VE ) STEEL ALONG Ly 131
( +VE ) STEEL ALONG Ly 283 ( +VE ) STEEL ALONG Ly 178

AREA OF STEEL PROVIDED ( Sq.mm ) SPACING OF STEEL PROVIDED ( mm C/C )

( -VE ) STEEL ALONG Lx 786 ( -VE ) STEEL ALONG Lx 100


( +VE ) STEEL ALONG Lx 524 ( +VE ) STEEL ALONG Lx 150
( -VE ) STEEL ALONG Ly 503 ( -VE ) STEEL ALONG Ly 100
( +VE ) STEEL ALONG Ly 335 ( +VE ) STEEL ALONG Ly 150

CHECK FOR DEFLECTION:

BASIC L/d RATIO 26


Provided.(+) ve pt.(IN SHORTER 0.42 THEORITICAL MODIFICATION FACTOR AS
SPAN) PER SP-24 1.34
Reqd.(+) ve pt.(IN SHORTER Permissible L/d ratio
SPAN) 0.33 39.10
EFF.DEPTH REQUIRED - d (mm) 120 EFF. DEPTH PROVIDED - d ( mm ) 125
HENCE DESIGN OF SLAB IS SAFE
cont..SLAB S1

SUMMARY OF SLAB :
SPACING OF STEEL PROVIDED (c/c) ( mm )
GRADE OF CONCRETE M 20 ( -VE ) STEEL ALONG SHORT SPAN 100
GRADE OF STEEL Fe 415 ( +VE ) STEEL ALONG SHORT SPAN 150
THICKNESS OF SLAB ( mm ) 150 ( -VE ) STEEL ALONG LONG SPAN 100
DIA OF MAIN STEEL ( mm ) 10 ( +VE ) STEEL ALONG LONG SPAN 150
DIA OF DIST STEEL ( mm ) 8 No. OF EXTRA BARS OVER SUPPORTS 2

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

LX

LY

PROVIDE # 10 @ 150 mm. c/c


2No.s BARS OF # 10 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

SLAB S1
Design of walk Way slab

Span of the slab = 2.200 m

Thickness of the at support = 0.20 m

Thickness of the at free end = 0.20 m

Grade of steel = M 20

Grade of concrete = 415 N / mm 2

Live load on the slab = 3.00 Kn / m 2

Floor finishing = 1.00 Kn / m 2

Width of the slab = 1000 mm

Effective depth = 175.0 mm

Diameter of main bar = 12 mm

Diameter of distribution bar = 8 mm

Load on slab :

Dead load = ( 0.2 + 0.2 ) x 0.5 x 25 = 5

Live load = 3.00

Floor finishing = 1.00

9.00 Kn / m 2

Bending moment = 1.5 x 9 x 2.2 ^ 2


2
= 32.670 Kn - m
Minimum area of steel required as per IS-456 = 210.0 mm 2
( 0.12% of crossectional area )

Area of steel required from BM consideration = 553.67 mm 2

Max spacing required as per IS-456 = 450.0 mm

Spacing required for minimum steel = 538.8 mm

Spacing required for BM consideration = 204.4 mm

Spacing of main steel provide = 125 mm

Area of main steel provided = 905.1 mm 2

Distribution steel :

Spacing required = 239.46 mm

Provide distribution steel spacing = 200 mm

Check for Deflection :

Basic L/d Ratio = 7

Percentage of steel provided = 0.52

Percentage of steel required = 0.32

Permissible L/d ratio = 12.58

Effective depth required = 174.94 mm

Effective depth provided = 175.0 mm Hence safe