APP0490-024-01A KEEP WITH USER MANUAL

Application Note for Using the Operator Station


HE500TIU050 / 10X / 11X / 20X / 3XX with
the Samsung Brian SPC 10/100/300 PLC’s

1.0. Protocol File Name


HE500TIU050 = Samsung_R?.0xx
HE500TIU1xx = Samsung _R?.1xx
HE500TIU2xx = Samsung _R?.2xx
HE500TIU3xx = Samsung _R?.3xx
(The “?” = the TIU firmware revision)

2.0. Configuring the Operator Station


To verify the Automated Equipment type the Operator Station is setup for, watch the
screen of the Operator Station on power up. The first screen message details the
setup of the Operator Station. To configure the Operator Station for particular
Automated Equipment, select the Automated Equipment in the Communication
Settings from the Configure menu in CBREEZE software. Select the appropriate
Manufacturer and the appropriate Remote Equipment Model. Then from the File
menu select Update Protocol, the appropriate file name will appear in the file name
field. The programmer may need to point to the correct folder name/location. If
further information is required see the manual or CBREEZE help on update/change
protocol.

3.0. Protocol Revisions


The Samsung Protocol gives the TIU Series access to read and write the various
register types of the PLC. All accesses are performed on word addresses as shown
in the Parameter Configuration section.

4.0. Serial Port Configuration


Care should be taken to match both ends of the link for baud rate. The default setting
for the TIU being 9600 baud with eight data bits, one stop bit and even parity.
Connectrion is typically via two wire RS485 cabling.

5.0. Node Address or Inherent CPU Number.


The Inherent Number is specified in Status Register W2560.
In the SPC Series the inherent numbers must not be duplicated and the user can
preset and freely use within the range 0 –191. If the inherent number 255 is selected,
all PLC CPUs connected to the network are selected. This is useful if the inherent
number of the PLC is not known but can ONLY be used when one unit is connected
to the TIU.

Page 1 of 3
Horner Electric APG Horner Europe APG
640 North Sherman Drive Unit 1. Centerpoint, Centerpark Rd.
Indianapolis, Indiana Cork, Ireland.
Phone : (317) – 916-4274 Phone : +353 (0)21 4321 266
Fax : (317) 916-4287 Fax : +353 (0)21 4321 826
Website : www.heapg.com Website : www.horner-apg.com
Technical Support : techsppt@heapg.com Technical Support : tech.support@hornerirl.ie
APP0490-024-01A KEEP WITH USER MANUAL

6.0. Parameter Specification

Register Assignment
Description ID Address Word Address
External R 00000 – 00007 0
Inputs
00100 – 00107 1
00200 – 00207 2
00300 – 00307 3

External R 01500 – 01505 15


Outputs
01600 – 01605 16
01700 – 01705 17
01800 – 01805 18

Internal Relay M 00000 – 00015 0


00100 – 00115 1
00200 – 00215 2
. .
03100 – 03115 31
Keep Relays K 00000 – 00015 0
00100 – 00115 1
00200 – 00215 2
. .
01500 – 01515 15

Special F 00000 – 00015 0


Internal
Relays 00100 – 1
001115

Timer TIM 000 – 255 0 – 255

Counter CNT 000 – 255 0 – 255

Status SST W2560 – 2560 – 2738


W2738

Word Register W 0000 – 0255 0 – 255

Page 2 of 3
Horner Electric APG Horner Europe APG
640 North Sherman Drive Unit 1. Centerpoint, Centerpark Rd.
Indianapolis, Indiana Cork, Ireland.
Phone : (317) – 916-4274 Phone : +353 (0)21 4321 266
Fax : (317) 916-4287 Fax : +353 (0)21 4321 826
Website : www.heapg.com Website : www.horner-apg.com
Technical Support : techsppt@heapg.com Technical Support : tech.support@hornerirl.ie
APP0490-024-01A KEEP WITH USER MANUAL

7.0. Connection details to a Samaung SPC10/100/300 PLC


13-Pin Screw Terminal Block 8-Pin Screw Terminal 25-Pin D-Type Male
1 13
1 1

14 25

TIU100, TIU110 TIU050, 101, 102, 103, TIU300, 301, 302, 303, 304,
111, 112, 113, 201, 310, 311, 312, 313, 314,
202, 203 320, 321, 322, 323, 324

Samsung SPC
TIU Type 13- 8- 25- 10/100/300
Pin Pin Pin RS422 Connection 9 Pin Male
Signal Name D type (Rear)
+5V 1 Twisted Shielded Pairs
TX 485/422+ 2 1 12 1
TX 485/422- 3 2 13 2
RX 485/422+ 4 3 24 • 3
RX 485/422- 5 4 25 • 4
TX RS232 6 5 2 0V 5
Signal GND 7 6 7 RS 485/422- 6
RX RS232 8 7 3 RS 485/422+ 7
Frame Gnd 13 8 1 8
RTS RS232 - - 4 9
CTS RS232 - - 5
RTS 485/422+ - - 14
RTS 485/422- - - 17
CTS 485/422- - - 18
CTS 485/422+ - - 19

Do not connect to unlisted pins.

Recommended cable : Beldon 9503, twisted multipair, screened.


Connect the screens together at the shield / Earth pin of the PLC

Configuration Bank
OFF
Switch ON OFF
1 Pull-up No Pull-up ON
2 120 termination No termination
4 3 2 1
3 Pull-down No Pull-down
4 Reserved for future use SW1
NOTE: Switch 1 and 3 must be used together

Page 3 of 3
Horner Electric APG Horner Europe APG
640 North Sherman Drive Unit 1. Centerpoint, Centerpark Rd.
Indianapolis, Indiana Cork, Ireland.
Phone : (317) – 916-4274 Phone : +353 (0)21 4321 266
Fax : (317) 916-4287 Fax : +353 (0)21 4321 826
Website : www.heapg.com Website : www.horner-apg.com
Technical Support : techsppt@heapg.com Technical Support : tech.support@hornerirl.ie

You might also like