You are on page 1of 14

DGS&D QA Inspection Report for Copper Alloy Float Valves (Horizontal Version-1

Plunger Type) DQA/GE/RC-116


(To be reported separately for each type/size) (1)
QA Office File no. Inspection Call No
and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores :-Copper Alloy Float Valves Quantity offered
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS 1703:2000 (Reaffirmed 2010)& IS:9762/1994 Reaffirmed 2009)
Classification ( CL.No. 3.1) :HP/LP
Size (CL.No 4):
No. of Samples drawn
Verify correctness Constructions\ Casting Material Machining
as per contract (CL.No 7) (CL.No 6.1) (CL.No 5) (CL.No 6.2)
(Tick √) Workmanship & Finish Threading/Gauging Finish
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
FLOAT VALVES IS 1703/2000
Visual Examination
Dimensions (Attached separate sheet) Table 2 to 6
Hydraulic test (Cl 8.1)
Shutting off test (Cl 8.2)
Mechanical Strength test of lever (Cl 8.3)
FLOAT IS 9762/1994
Visual Examination
Dimensions (Attached separate sheet ) (Cl 6)
Lifting Effort (Cl 3.2)
Leakage & Water Absorption Test (Cl 8.1)
Deflection Test (Cl 8.2)
Impact Test (Cl 8.3)
Boss Test :- (Cl 8.4)
a)Torque Test
b)Pull Test
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all
specimens to be reported on separate sheets and only the final value as applicable shall be reported in the table
above. * Values and tolerances of different parameters shall be in accordance with the contract and shall be noted
in the first column. *All tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer
test certificate as per relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of
Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Nickel Chrome Plated Cast Brass Version-1
Pillar Taps For Water Supplies Purposes DQA/GE/RC-116
(To be reported separately for each type/size) (2)
QA Office File no. Inspection Call No and
date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Nickel Chrome Plated Cast Brass Pillar Taps For Quantity offered
Water Supplies Purposes
Date of Inspection Date(s) of Quantity Inspected
Call Inspection
Specification IS 1795:1982 (Reaffirmed 2010)
Size (Cl 3.1) :-
Anti Splash Device :- Provided/Not Provided
No. of Samples drawn
Verify correctness Material (Cl 4) Construction (Cl 6) Marking (Cl Finish (Cl 8)
as per contract (Tick 11)
√)
Manufacture & Workmanship (Cl 5)
Test Results Sample no.
Parameter Requiremen 1 2 3 4 5
t
Visual Examination
Dimension as per Table 2 to
Table 6 (Attached Separate
Sheet)
Mass (Cl 7)
Hydraulic Pressure Test (Cl 11)
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted
for different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all
specimens to be reported on separate sheets and only the final value as applicable shall be reported in the
table above. * Values and tolerances of different parameters shall be in accordance with the contract and shall
be noted in the first column. *All tests as per R.C spec shall be conducted. . *Where applicable raw material
manufacturer test certificate as per relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I Name, designation, seal of Inspector
mark
Name, Designation and seal of supplier
Date
Place
GS&D - QA Inspection Report for Nickel Chrome Plated Brass Waste Fittings Version-1
(To be reported separately for each type/size) DQA/GE/RC-116
(3)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Nickel Chrome Plated Brass Waste Fittings Quantity offered
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS 2963:2013
Application :Wash Basin/Sinks
Nominal Size :
No. of Samples drawn
Verify correctness as per Material ( Cl 2) Finish (Cl 5) Marking (Cl 6)
contract (Tick √) Manufacture & Workmanship ( Cl 3)
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimension (Cl 4.2)
(Attached separate sheet)
Thickness Of Plating ( Cl 5.1)
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for different tests and
criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to be reported on separate sheets
and only the final value as applicable shall be reported in the table above. * Values and tolerances of different parameters shall be in
accordance with the contract and shall be noted in the first column. *All tests as per R.C spec shall be conducted. . *Where
applicable raw material manufacturer test certificate as per relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Nickel Chrome Plated Cast Brass Mixing Valves Version-1
(To be reported separately for each type/size) DQA/GE/RC-116
(4)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Nickel Chrome Plated Cast Brass Mixing Valves Quantity offered
Date of Inspection Date(s) of Quantity Inspected
Call Inspection
Specification IS 1701:1960 (Reaffirmed 2012)
Size:
Purpose: Ablutionary/Domestic
No. of Samples drawn
Verify correctness as Material (Cl 4) Manufacture ( Cl 5) Workmanship (Cl 6) Marking ( Cl 8)
per contract (Tick √) Test Results Sample no.
Parameter Requirement 1 2 3 4 5 6
Visual Examination
Thickness of Plating Ni/Cr ( Cl 5.1.3)
Hydraulic Pressure test (Cl 7.1.1 &
Cl 7.1.2)
Head loss test ( Cl 7.2)
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for different
tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to be
reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of
supplier
Date
Place
DGS&D - QA Inspection Report for Nickel Chrome Plated Cast Brass Fancy Taps Version-1
For Water Supplies Purposes, For Normal/With Flow-Straightening DQA/GE/RC-116
Devices/With Aerating Devices Operation (5,6,7)
(To be reported separately for each type/size)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Nickel Chrome Plated Cast Brass Fancy Taps For Quantity offered
Water Supplies Purposes,
For Normal With Flow-Straightening Devices
With Aerating Devices Operation
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS 8931:1993 (Reaffirmed 2013)& IS:8376/1988
TYPE :
SIZE :
No. of Samples drawn
Verify correctness as per Manufacture & Workmanship Cl 6 Construction Cl 6 Material Cl 5 & 9.1
contract (Tick √) Marking Cl 11 Finish Cl 8
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
FANCY TAPS IS: 8931/93
WITH AMDT NO. 1

Visual Examination
Dimensions Attached Separate sheet table 2 to 9
PERFORMANCE ( CL 9.2 )
a) Water Tightness Characteristic ( CL 9.2.1 )
b) Pressure Resistance Characteristic ( CL 9.2.2 )
c) Hydraulic Characteristic ( CL 9.2.3 )
d) Mechanical Strength Characteristic ( CL 9.2.4 )
TESTING OF NICKEL CHROMIUM PLATING IS:8376/1988
a) Thickness Test ( Cl 7.1 )
b) Thermal Cycling Test ( Cl 7.2 )
c) Corrosion Resistance Test ( Cl 7.3 )
d) Ductility Test ( Cl 7.4 )
NICKEL CHROMIUM PLATING TEST IS:1068/1993
a) Thickness of plating Cl 9.1
b) Adhesion Cl 9.2
c) Corrosion Resistance Cl 9.3
d) Ductility Cl 9.4
Any other tests as per R/C
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to
be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of
supplier
Date
Place
DGS&D - QA Inspection Report for Self Closing Taps For Water Supply Purpose Version-1
( To be reported separately for each type & size ) DQA/GE/RC-116
(8)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Self Closing Taps For Water Supply Quantity offered
Purpose
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS: 1711/1984 (Reaffirmed 2010)
Type:
Size:
No. of Samples drawn
Verify correctness as per Manufacture & Workmanship Cl Material Cl 4.1 Operation Cl 6 Finish Cl 7
contract (Tick √) 5.1
Marking Cl 10
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimension Cl 3.1
( Attached separate sheet )

Hydraulic Pressure Test Cl 8.1

Water Flow Test Cl 8.2

Endurance Test Cl 8.3

Thickness of Nickel Plating Cl7. 3

Any other tests as per R/C


Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens
to be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values
and tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column.
*All tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per
relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of
supplier
Date
Place
DGS&D - QA Inspection Report for Cast Brass Down Bib Taps/Stop Version-1
Valves For Water Services DQA/ GE/RC-116
( To be reported separately for each type & size ) (9)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Cast Brass Down Bib Taps Quantity offered
Stop Valves For Water Services
Date of Inspection Date(s) of Inspection Quantity Inspected
Call
Specification IS:781/1984 (Reaffirmed 2010)with amdts no 1,2
Type:
Size:
No. of Samples drawn
Verify Construction & Workmanship Material Cl 4 Finish Cl 8 Marking Cl 11
correctness as Cl 6
per contract (Tick Test Results Sample no.
√)
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimensions Cl 5
Attached separate sheet
Mass Cl 7
Thickness of Nickel Cl 8.3
Chromium Plating
Hydraulic Test Cl 9.1
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens
to be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values
and tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column.
*All tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per
relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of
Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Check Valves for waterworks purposes Version-1
( To be reported separately for each type & size ) DQA/GE/RC-116
(10)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Check Valves for waterworks purposes Quantity offered
Date of Inspection Date(s) of Quantity Inspected
Call Inspection
Specification IS: 778:1984 (Reaffirmed 2010)
Type Cl 5:
Size Cl 3:
Class Cl 4:
No. of Samples drawn
Verify correctness as per Design & Manufacture Cl 7 Material Cl 6 Marking Cl 13
contract (Tick √) Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimensions Cl 8
(Attached separate sheet)
Hydrostatic test Cl 9.3
Back seat test Cl 9.4
Seat test Cl 9.5
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for different
tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to be reported
on separate sheets and only the final value as applicable shall be reported in the table above. * Values and tolerances of
different parameters shall be in accordance with the contract and shall be noted in the first column. *All tests as per R.C
spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant specification shall
be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of
supplier
Date
Place
DGS&D - QA Inspection Report for Plug Cocks For Water Supply Purposes Version-1
( To be reported separate for each size ) DQA/GE/RC-116
(11)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Plug Cocks For Water Supply Purposes Quantity offered
Date of Inspection Date(s) of Quantity Inspected
Call Inspection
Specification IS:3004/1979 (Reaffirmed 2010)
Size:
No. of Samples drawn
Verify correctness as Manufacture & Workmanship Cl 6 Material Cl 5 Construction Cl 7 Finish Cl 8
per contract (Tick √) Assembly Cl 9 Marking Cl 11
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Size Cl 4
Dimensions ( Table 1 & 2)
(Attached separate sheet).
Hydraulic test Cl 10
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for different
tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to be
reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Water shower – Brass/SS Version-1
(To be reported separate for each type & size ) DQA/GE/RC-116
(12)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Water shower – Brass/SS Quantity offered
Date of Inspection Date(s) of Inspection Quantity Inspected
Call
Specificatio IS:292/1983, IS:1264/1997, IS:318/1981, IS:5522/2014, IS:1068/1993, & R/C Specns
n
Type:
Size:
No. of Samples drawn
Verify correctness as per contract (Tick Workmanship & Construction Material Finish Marking
√) Freedom from defects
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
LEADED BRASS CASTING IS:292/1983
a) Size & Shape Cl 6
b)Dimensions
( Attached separate sheet )
c)Chemical Composition Cl 3
( Attached separate sheet)
d) Pressure test Cl 4
e) Freedom from defects Cl 5
LEAD TIN BRONZE CASTING IS:318/1981
a) Chemical Composition Cl 3.1
( Attached separate sheet )
b) Mechanical properties Cl 4.1
c) Pressure test Cl 5.1
d) Freedom from defects Cl 6
e) Sizes & shape Cl 7
LEADED BRASS CASTING IS:292/1983
a) Size & Shape Cl 6
b)Dimensions
( Attached separate sheet )
c)Chemical Composition Cl 3
( Attached separate sheet)
d) Pressure test Cl 4
e) Freedom from defects Cl 5
STAINLESS STEEL SHEET IS:5522/2014
a) Manufacture Cl 5.1
b) Freedom from defects Cl 6
c)Chemical Composition Cl 7
( Attached separate sheet )
d)Tensile test Cl 8.1 & Cl 8.2
e)Hardness test Cl 8.3
f) Erichsen cupping test Cl 8.4
g) Dimensions Cl 9
NICKEL CHROMIUM PLATING IS:1068/1993
TEST
a) Thickness of plating Cl 9.1
b) Adhesion Cl 9.2
c) Corrosion Resistance Cl 9.3
d) Ductility Cl 9.4
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to
be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Towel Rail Brass Version-1
( To be reported separately for each type & size ) DQA/ GE/RC-116
(13)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Towel Rail Brass Quantity offered
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS:1068/1993 & R/C SPECIFICATION
Size:
Service Condition:
No. of Samples drawn
Verify correctness as per Manufacture & Workmanship Construction Finish Marking
contract (Tick √) Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimension
(Attached separate sheet)
NICKEL CHROMIUM IS:1068/1993
PLATING TEST
a) Thickness of plating Cl 9.1
b) Adhesion Cl 9.2
c) Corrosion Resistance Cl 9.3
d) Ductility Cl 9.4
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to
be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Towel Ring Brass Version-1
( To be reported separately for each type & size ) DQA/ GE/RC-116
(14)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Towel Ring Brass Quantity offered
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS:1068/1993 & R/C SPECIFICATION
Size:
Service Condition:
No. of Samples drawn
Verify correctness as per Manufacture & Workmanship Construction Finish Marking
contract (Tick √) Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimension
(Attached separate sheet)
NICKEL CHROMIUM IS:1068/1993
PLATING TEST
a) Thickness of plating Cl 9.1
b) Adhesion Cl 9.2
c) Corrosion Resistance Cl 9.3
d) Ductility Cl 9.4
Any other tests as per R/C
Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens to
be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values and
tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column. *All
tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per relevant
specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of supplier
Date
Place
DGS&D - QA Inspection Report for Flushing Valve For Water Supply Purpose Version-1
( To be reported separately for each type & size ) DQA/GE/RC-116
(15)
QA Office File no. Inspection Call No and date
RC/Order no. Quantity ordered
Supplier Place of Inspection
Description of Stores Flushing Valve For Water Supply Purpose Quantity offered
Date of Inspection Call Date(s) of Inspection Quantity Inspected
Specification IS: 778:1984 (Reaffirmed 2010).& drg No.116/01/2010
Type:
Size:
No. of Samples drawn
Verify correctness as per Manufacture & Workmanship Cl Material Cl 4.1 Operation Cl 6 Finish Cl 7
contract (Tick √) 5.1
Marking Cl 10
Test Results Sample no.
Parameter Requirement 1 2 3 4 5
Visual Examination
Dimension Cl 3.1
( Attached separate sheet )

Hydraulic Pressure Test Cl 8.1

Water Flow Test Cl 8.2

Endurance Test Cl 8.3

Thickness of Nickel Plating Cl7. 3

Any other tests as per R/C


Notes:
* Use extra sheets if required * Number of specimen to be tested for each sample and test methods adopted for
different tests and criterion of conformity shall be as specified in the governing spec/R/C. * Results on all specimens
to be reported on separate sheets and only the final value as applicable shall be reported in the table above. * Values
and tolerances of different parameters shall be in accordance with the contract and shall be noted in the first column.
*All tests as per R.C spec shall be conducted. . *Where applicable raw material manufacturer test certificate as per
relevant specification shall be obtained from the supplier.
Conclusion:
Quantity accepted Quantity rejected
Packing details to be incorporated in I Note
How I Mark put Facsimile of I mark Name, designation, seal of Inspector
Name, Designation and seal of
supplier
Date
Place