You are on page 1of 7

www.hilti.in Profis Anchor 2.6.

5
Company: Page: 1
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-RE 500 + HIT-V (5.8) M16
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 100 mm (hef,limit = - mm)
Material: 5.8
Evaluation Service Report: ETA 04/0027
Issued I Valid: 6/26/2013 | 5/16/2018
Proof: Engineering judgement SOFA BOND - based on ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 20 mm
Anchor plate: lx x ly x t = 1000 mm x 1000 mm x 20 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C20/25, fc = 25.00 N/mm2; h = 140 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to EOTA TR 029, 5.2.2.6 present.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 2
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads
8 9
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
7 10
Anchor Tension force Shear force Shear force x Shear force y
1 0.016 11.612 2.007 11.437
2 1.132 12.712 8.722 9.248
6 x 1
3 4.045 13.347 12.872 3.529 Tension Compression
4 7.640 13.347 12.872 -3.529
5 10.552 12.712 8.722 -9.248
5 2
6 11.666 11.612 2.007 -11.437
7 10.550 10.385 -4.725 -9.248
4 3
8 7.636 9.551 -8.875 -3.529
9 4.042 9.551 -8.875 3.529
10 1.130 10.385 -4.725 9.248
max. concrete compressive strain: 0.08 [‰]
max. concrete compressive stress: 2.37 [N/mm2]
resulting tension force in (x/y)=(-174/0): 58.406 [kN]
resulting compression force in (x/y)=(436/0): 68.406 [kN]

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 11.666 52.667 23 OK
Combined pullout-concrete cone failure** 58.406 124.520 47 OK
Concrete Breakout Strength** 58.406 83.401 71 OK
Splitting failure** 58.406 76.383 77 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
79.000 1.500 52.667 11.666

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] 2
tRk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
675259 90000 15.00 300 150 ∞
2 0
yc tRk,ucr [N/mm ] k yg,Np yg,Np
1.000 15.00 3.200 1.000 1.000
ec1,N [mm] yec1,Np ec2,N [mm] yec2,Np ys,Np yre,Np
174 0.462 0 1.000 1.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
75.398 261.492 2.100 124.520 58.406

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm]
675259 90000 150 300
ec1,N [mm] yec1,N ec2,N [mm] yec2,N ys,N yre,N k1
174 0.462 0 1.000 1.000 1.000 10.100
N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
50.500 2.100 83.401 58.406

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 3
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

3.4 Splitting failure


Ac,N [mm2] A0c,N [mm2] ccr,sp [mm] scr,sp [mm] yh,sp
991452 173056 208 416 1.020
ec1,N [mm] yec1,N ec2,N [mm] yec2,N ys,N yre,N k1
174 0.544 0 1.000 1.000 1.000 10.100
N0Rk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
50.500 2.100 76.383 58.406

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 4
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 13.347 31.200 43 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength* 13.347 49.817 27 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
39.000 1.250 31.200 13.347

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] k-factor
66588 90000 150 300 2.000
ec1,V [mm] yec1,N ec2,V [mm] yec2,N ys,N yre,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,c1 [kN] VSd [kN]
50.500 1.500 49.817 13.347

5 Combined tension and shear loads (EOTA TR 029, Section 5.2.4)


bN bV a Utilization bN,V [%] Status
0.765 0.428 1.500 95 OK
a a
bN + bV ≤ 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 5.659 [kN] dN = 0.045 [mm]
VSk = 9.886 [kN] dV = 0.395 [mm]
dNV = 0.398 [mm]
Long term loading:
NSk = 5.659 [kN] dN = 0.090 [mm]
VSk = 9.886 [kN] dV = 0.593 [mm]
dNV = 0.600 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 5
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

7 Warnings
• Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• An SLS-check is not performed for SOFA and has to be provided by the user!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 6
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

8 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-RE 500 + HIT-V (5.8) M16
Profile: no profile Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 20 mm Hole depth in the base material: 100 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 136 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Dispenser including cassette and mixer
• Properly sized drill bit • Proper diameter wire brush • Seismic/Filling set
y • Torque wrench

500 500

167
8 9

127

500
7 10

206

6 1 x
206

5 2
500
127

4 3
168

150 67 175 216 175 67 150

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 350 0 - - - - 6 -350 0 - - - -
2 283 -206 - - - - 7 -283 206 - - - -
3 108 -333 - - - - 8 -108 333 - - - -
4 -108 -333 - - - - 9 108 333 - - - -
5 -283 -206 - - - - 10 283 206 - - - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.6.5
Company: Page: 7
Specifier: Project: Luwa
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 5/6/2016
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like