You are on page 1of 1

DESIGN CALCULATIONS

REF COLUMN MARK;- C1 Summery


Factored load = 700 KN
Floor height = 3.4 m
Un supported lenth in -x- direction = 2.9 m
Un supported lenth in -y- direction = 2.9 m
Width of column = 200 mm
fy = 415 N/mm2 fck = 20 N/mm2

Check for slenderness ratio;-


Condition, (L/rmin) >12, Long column
(L/rmin) = 17
Column is slender

Design of column as;-


Assume ( Asc) = 1 %A g Asc = 0.01 A g
Ac = Ag-Asc Ac = 0.99 A g
Pu = .4 fck Ac+.67 fyAsc
700 = 7.92 A g + 2.7805 A g
Ag = 65417.5 mm2
D = 327 mm Dpro = 500 mm
Additional Moments;-
SP-16 eax/D = 0.072 eay/b = 0.145
Table I eax = 36 mm eay = 29 mm
Max = 25.2 KN-m May = 20.3 KN-m

Modifaction factor;-
K = {(Puz-Pu)/(Puz-Pb)}
Assuming 1 % reinforcement for the first trial
SP-16 P/fck = 0.05 Pu/Ag = 16.5
Chart-63 Puz = 1650 KN d' = 50 mm
d'/D = 0.10
SP-16 K1 = 0.212 K2 = 0.088
Table 60 Pbx=Pby = {K1+K2(P/fck)}fck b D = 432.8
K = 0.78 ≤1 OK

Additional moments are modified as;-


Max = 19.67 KN-m May = 15.84 KN-m

Minimum ecentricities;-
IS 456-2000 ex = 22.4667 ex min = 25 mm
Clause25.4 ey = 12.47 ey min = 10 mm
Mux min = 15.7267 KN-m Muy min = 8.727 KN-m
Total moment;-
Mux = 40.9267 KN-m Muy = 29.03 KN-m
2
SP-16 (Pu/fckxbxD) = 0.35 Mu/fckxbxD 0.100
Chart-44 Mux1 = 100 KN-m Muy1 = 40 KN-m
Mux/Mux1 = 0.41 Muy/Muy1 = 0.726
Pu/Puz = 0.42
SP-16 Muy/Muy1 = 0.78 > 0.73 OK
Chart-64
Area of steel required;-
Ast = PbD/100 1000 mm2
Assume 16 mm bars 5 Say 6
Summery
Column size (mm) Main Reinforcement Stirrups
200 500 6 y 16 Y8 @ 15c/c