You are on page 1of 66

Hydraulic Power Units

D, H, V-Pak and V-Pak Low Profile Series


HY28-2661-CD/US
Effective: Mar 31, 2016
WARNING - USER RESPONSIBILITY
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.

© Copyright 2016, Parker Hannifin Corporation. All Rights Reserved.


HY28-2661-CD/US Hydraulic Power Units
Contents D, H and V-Pak Series

Contents
D, H and V-Pak Series
Introduction........................................................................................................................ 2-3
Ordering Information........................................................................................................ 4-10
Installation Information.................................................................................................. 11-13
Technical Information.................................................................................................... 14-30
H-Pak with DCP
Introduction.................................................................................................................... 32-33
Ordering Information......................................................................................................... 6-8
Installation Information........................................................................................................27
Safety & Technical Information.................................................................................... 34-40
V-Pak Low Profile Series
Introduction.................................................................................................................... 42-43
Ordering Information..................................................................................................... 44-45
Installation Information........................................................................................................46
Technical Information.................................................................................................... 47-58
Additional Installation Information.........................................................................................59
Additional Technical Information............................................................................................60
Conversion Equations..............................................................................................................61
Offer of Sale..............................................................................................................................63

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 1
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Introduction
Catalog HY28-2661-CD/US Vertical Power Units D, H and V-Pak Series
Introduction Volume
Series DControl
, H, V-Paks

Quick Reference Data Chart


Pump Flow Electrical
Pump Tank Size LPM (GPM) Motors Maximum*
Model No. Liters (Gallon) @ 1725 RPM KW (HP) Bar (PSI)
D-Paks 18.9 (5) 3.4 - 10.2 (0.9 - 2.7) 0.37 (0.5) - 2.24 (3) 207 (3000)

H-Paks 37.9 (10), 75.7 (20), 113.6 (30), 151.4 (40) 3.4 - 36.3 (0.9- 9.6) 0.37 (0.5) - 14.9 (20) 207 (3000)

V-Paks 37.9 (10), 75.7 (20), 113.6 (30), 151.4 (40) 7.6 - 59.1 (2.0 - 15.6) 1.5 (2) - 14.9 (20) 207 (3000)

V8 302.8 (80) 41.6 - 136.7 (11.0 - 36.1) 5.6 - 30 (7 1/2 - 40) 207 (3000)

* See pump/motor combination, maximum pressure charts.

2 Parker
Parker Hannifin Hannifin Corporation
Corporation
Hydraulic Pump DivisionPump and
Hydraulic
Maryville, Ohio USA Systems Division
Power
2
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Catalog HY28-2661-CD/US Vertical Power Units
Introduction
Technical Information Volume
S Control
eries DPower
, H, V-Paks
D, H and V-Pak Series
Catalog HY28-2661-CD/US Vertical Units
Technical Information Volume Control
Series D, H, V-Paks
Warranty
The hydraulic components on these Parker Power
Warranty
Units are warranteed for one year. This warranty
The hydraulic components on these Parker Power
may be extended to two years by using and
Units are warranteed for one year. This warranty
properly maintaining Parker filters.
may be extended to two years by using and
properly maintaining Parker filters.
Installation Data:
See Installation/Maintenance Manual for specific
Installation Data:
recommendations pertaining to start-up, system
See Installation/Maintenance Manual for specific
cleanliness, fluids, temperature and other important
recommendations pertaining to start-up, system
factors relative to proper installation and use of
cleanliness, fluids, temperature and other important
these power units.
factors relative to proper installation and use of
these power units.

Standard Features
Standard
• VerticalFeatures
Design Benefits
• Submerged Pump
Vertical Design Benefits
• Saves Floor Space
Spare ReturnPump
• Submerged Ports QuieterFloor
• Saves Operation,
Space Elimination of Potential
• Precision Pump
Spare Return Mounting Adapters
Ports Leak Point
• Quieter Operation, Elimination of Potential
Suction Strainer
• Precision Pump Mounting Adapters • Longer Pump Life
Leak Point

Glycerine
• Suction Filled Pressure Gage with Shut Off
Strainer ProtectsPump
• Longer PumpLife
from Contamination

• Glycerine
Oil Level Gage
Filledwith Thermometer
Pressure Gage with Shut Off • Improved Diagnostics
Protects Pump from Contamination

Relief
• Oil Valve
Level Gage with Thermometer Helps to Maintain
• Improved Trouble-Free Performance
Diagnostics

• Breather and Fill Cap


Relief Valve • Protects
Helps to Against
MaintainSystem ShockPerformance
Trouble-Free

• SAE Drainand
Breather Plug
Fill Cap • Easy To Fill
Protects Reservoir
Against System Shock

• SAE
Parker Connector
Drain Plug Technology • Easy
Prevents Leaks
To Fill Reservoir

•• Parker
Available with Digital
Connector Drives
Technology • Prevents Leaks
(See DCP Pak section of this catalog)
• Available with Digital Drives
Schematic
(See DCPSymbol
Pak section of this catalog)
(Hydraulic Schematic - Basic Unit)
Schematic Symbol
(Hydraulic Schematic - Basic
P Unit)
T P T
“O” “O”
OPTION X P T P A X OPTION X P T P A X
MANIFOLD
“O” MANIFOLD
“O”
OPTION X T
P B
A X
X OPTION X T
P B
A X
X
MANIFOLD MANIFOLD
T B X T B X

M SPARE
M SPARE
M RETURN M RETURN
SPARE “OMIT” SPARE
RETURN OPTION RETURN
COMP
“OMIT”
CONTROL
OPTION
SAE X SAE X
-12 -12 COMP
CONTROL
SAE X
D & H-PAK BASIC UNIT SAE X
V-PAK BASIC UNIT
-12 ——————————— -12 —————————
NO OPTIONS
D & H-PAKORBASIC
ACCESSORIES
UNIT NO OPTIONS OR ACCESSORIES
V-PAK BASIC UNIT
———————————
“O” OPTION MANIFOLD —————————
“OMIT” OPTION PUMP COMPENSATOR
NO OPTIONS OR ACCESSORIES NO OPTIONS OR ACCESSORIES
“O” OPTION MANIFOLD
“O” OPTION MANIFOLD “OMIT” OPTION PUMP COMPENSATOR
3 “O” OPTION MANIFOLD
Parker Hannifin Corporation
Parker Hannifin Corporation Hydraulic Pump Division
Maryville,
Parker Ohio USA
Hannifin Corporation
Hydraulic Pump and 3
Power Systems Division Hydraulic Pump Division
3 Maryville, Ohio USA
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
D-Paks Ordering Information D-Paks

D5 P
Reservoir Pressure Pump Flow D = Dual Rated• Electric Manifold Directional Manapak Options
18.9 Liters Control W = No Motor•• Motor Control Control and
(5 Gal) Valve Valves• Accessories

Code Pressure Control Nominal


Directional NFPA
Flow Circuit
Omit System Pressure Relief Valve Only Code Control Valve Mounting Description
GPM Symbol
Model Number Pad
System Pressure Relief Valve with Unloading Valve (2-Way (LPM)
B
120VAC) N.O. (Energize coil to close) Double AB

B D1VW001CN*** D03 7 (26.5)


System Pressure Relief Valve with Unloading Valve (2-Way (Spr. Ctr) PT

J
24VDC) N.O. (Energize coil to close) Double AB

C D1VW004CN*** D03 7 (26.5)


(Spr. Ctr) PT

Code Pump Flow Used Double AB

T D1VW008CN*** D03 7 (26.5)


(Spr. Ctr) PT
0.9 331-9110-267
Units less valves will be supplied with station cover plates installed.
1.3 331-9110-011
1.8 331-9110-010 Manapak Nominal
NFPA
2.7 331-9110-101 Control Valve Model Flow Circuit
Code Mounting
Valves Number GPM Symbol
Pad
Function (LPM)
If No Motor or Electric Motor Description Flow Control
Code 1 FM2DDKN D03 7 (26.5)
Dual Rated HP (KW) - RPM Frame Phase Meter-Out
U1 .5 (.37) - 1725-56C-1 Pilot Operator
3 CPOM2DDN D03 7 (26.5)
T1 1 (.75) - 1725-56C-1 Check

T3 1 (.75) - 1725-56C-3 Manapak valves mounted in order of callout.


First valve will be nearest DCV; last valve will be on manifold.
W G 56C (no motor)
D G 2 (1.5)-1725 - 56C-3* Options and Accessories
Code
D K 3 (2.2) - 1725-182TC* Function Model Number Technical Data
W L 182TC/184TC (no motor) Air/Oil: 0.7 HP (52 kW)
B1* Exchanger RM-08-2-2
Rej. @ 3 GPM (11.4 LPM)
D = DUAL RATED * Microglass II Element
W = NO MOTOR ** Pressure Vis. Ind. – 50 PSI (3.4 bar)
H 15P110QXRS
Single phase electric motors are rated as follows: Filter Bypass – 2 PSI (0.14 bar)
115/230V, 1PH, TEFC - 60 Hertz 1800 RPM Diff. @ 3 GPM (11.4 LPM)
5 PSI (0.34 bar) Cracking
Three phase electric motors are rated as follows: Check Valve Pressure
208-230/460V, 3PH, TEFC - 60 Hertz 1800 RPM 1.15 SF K DT370MOMF05
Pump Outlet 7 PSI (0.48 bar) Diff. @
• Dual rated motors include the 60Hz ratings plus 190/380V 50Hz (1.5SF) 3 GPM (11.4 LPM)
1450RPM 10:1CT/20:1VT INVERTER RATED UR/CSA/CSA EEV/CE Bypass
Check 65 PSI (4.5 bar) Cracking
• Options G & K are dual rated as standard. L C1020S65
(on Heat Pressure
•• Use W prefix when no motor is required on unit. Exch)
When ordering, W must be followed by motor model code equivalent to Cellulose Element
12AT10C
frame size of motor to be used. O Return Filter Ind. Gage - 15 PSI (1.03 bar)
45LPM (12 GPM)
Bypass Max. Oil Flow
DO NOT USE “W” and “D” together i.e. 56C frame unit with no motor is Combination
called out “WG”. Fixed Temp at 65°C (149°F)
Float/Temp.
R1 8767820-1 Close @ Low Level and/or
Switch
65°C (149°F) (N.O.)
Supply/Return N.O. Float Up
Porting Block/Subplate
Code Port or Other Combination
or Manifold Type Fixed Temp at 65°C (149°F)
Actuator Port Size Float/Temp.
R2 876782-02 Open @ Low Level and/or
Pressure and Return Switch
P & T Ports Convertible 65°C (149°F) (N.C.)
O Port Block with Safety Float Up
SAE-10 Str. Thr'd to S3 Option
Relief Valve *Heat rejection based on flow given with a 40°F differential
between transfer medium.
D03 Single Station Spare P &
A & B Ports
S3 Subplate with Safety T SAE-10
SAE-8 Str. Thr'd
Relief Valve Ports
D03 Multistation
A & B Ports Spare G
M33 Parallel Circuit Manifold
SAE-8 Str. Thr'd Port SAE-6
with Safety Relief Valve
Manifolds are mounted vertically. Bottom station is number 1.

= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump and
4 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Notes D-Paks

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 5
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
H-Paks Ordering Information H-Paks

Reservoir Pressure Pump Flow D = Dual Rated• Electric Manifold


Control W = No Motor•• Motor

Reservoir Size If No Motor Electric Motor Description


Code Code
Gallons (Liters) or Dual Rated HP (KW) - RPM Frame Phase
H1* 10 (37.9) N 10 (7.5) - 1725 - 215TC - 3
H2 20 (75.7) D N 10 (7.5) - 1725 - 215TC - 3 DUAL RATED
H3 30 (113.6) W P† 254TC (no motor)
H4 40 (151.4) P† 15 (11.2) - 1725 - 254TC - 3
*Available up to 7.5 KW (10 HP) motor only. D P† 15 (11.2) - 1725 - 254TC - 3 DUAL RATED
W S† 256TC (no motor)
Code Pressure Control* S† 20 (14.9) - 1725 - 256TC - 3
Omit System Pressure Relief Valve Only D S† 20 (14.9) - 1725 - 256TC - 3 DUAL RATED
System Pressure Relief Valve with Unloading Valve (2-Way
B Single phase electric motors are rated as follows:
120VAC) N.O. (Energize coil to close)
115/230V, 1PH, TEFC - 60 Hertz 1800 RPM
System Pressure Relief Valve with Unloading Valve (2-Way Three phase electric motors are rated as follows:
J 24VDC) N.O. 208-230/460V, 3PH, TEFC - 60 Hertz 1800 RPM 1.15 SF
(Energize coil to close)
• Dual rated motors include the 60Hz ratings plus 190/380V 50Hz (1.0SF)
1450RPM 10:1CT/20:1VT INVERTER RATED UR/CSA/CSA EEV/CE.
Code Pump Flow Used 2Hp & 3Hp S.F.=1.15
0.9 331-9110-267 • Dual rated motors except 2Hp & 3Hp may have longer than standard
leadtime. Options G & K are dual rated as standard.
1.3 331-9110-011
Consult factory for other motor speeds (RPM) and voltages.
1.8 331-9110-010
†Available with H2, H3 and H4 tanks only.
2.7 331-9110-101 •• Use W prefix when no motor is required on unit.
When ordering, W must be followed by motor model code equivalent to
3.2 334-9111-069 frame size of motor to be used.
4.5 334-9111-068 DO NOT USE “W” and “D” together i.e.: 182/184TC unit with no motor is
5.1 334-9111-067 called out “WL”.

6.3 334-9111-048
Supply/Return
8.1* 334-9111-065 Porting Block/
Port or
Code Subplate Other
9.6* 334-9111-049 Actuator Port
or Manifold Type
Size
*Do not select a motor smaller than 2 Hp with these flow rates.
Pressure and Return
P & T Ports Convertible to
O Port Block with Safety
If No Motor Electric Motor Description SAE-10 Str. Thr'd S3 Option
Code Relief Valve
or Dual Rated HP (KW) - RPM Frame Phase
D03 Single Station
U1 .5 (.37) - 1725-56C-1 A & B Ports Spare P & T
S3 Subplate with Safety
SAE-8 Str. Thr'd SAE-10 Ports
T1 1 (.75) - 1725-56C-1 Relief Valve
T3 1 (.75) - 1725-56C-3 D05 Single Station
A & B Ports Spare P & T
S5 Subplate with Safety
W G 56C (no motor) SAE-10 Str. Thr'd SAE-12 Ports
Relief Valve
D G 2 (1.5)-1725 - 56C-3 DUAL RATED
D03 Multistation
M33 A & B Ports Spare G Port
D K 3 (2.2) - 1725-182TC DUAL RATED Parallel Circuit Manifold
M35 SAE-8 Str. Thr'd SAE-6
with Safety Relief Valve
W L 182TC/184TC (no motor)
D05 Multistation
L 5 (3.75) - 1725 - 184TC - 3 M53 A & B Ports Spare G Port
Parallel Circuit Manifold
M55 SAE-8 Str. Thr'd SAE-6
D L 5 (3.75) - 1725 - 184TC - 3 DUAL RATED with Safety Relief Valve
W M 213TC (no motor) Manifolds are mounted vertically. Bottom station is number 1.
M 7.5 (5.6) - 1725 - 213TC - 3
D M 7.5 (5.6) - 1725 - 213TC - 3 DUAL RATED
W N 215TC (no motor)
Continued: top right.

= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump and
6 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
H-Paks Ordering Information H-Paks

P For DCP (inverter) options,


see next page
Directional Manapak Options and
Control Valve Control Valves• Accessories

Valve Model NFPA Mounting Nominal Flow Circuit


Code Description
Number Pad GPM (LPM) Symbol
Double AB

B D1VW001CN*** D03 7 (26.5)


(Spr. Ctr) PT

Double AB

C D1VW004CN*** D03 7 (26.5)


(Spr. Ctr) PT

Double AB

F D3W1CN** D05 20 (75.7)


(Spr. Ctr) PT

Double AB

G D3W4CN** D05 15 (56.8)


(Spr. Ctr) PT

Double AB

T D1VW008CN*** D03 7 (26.5)


(Spr. Ctr) PT

Double AB

W D3W8CN** D05 15 (56.8)


(Spr. Ctr) PT

Units less valves wil be supplied with station cover plates installed.

Valve Model NFPA Nominal Flow


Code Function Circuit Symbol
Number Mounting Pad GPM (LPM)
Flow
1 FM2DDKN D03 7 (26.5)
Control
Flow
2 FM3DDKN D05 12 (45.4)
Control
Pilot
3 Operator CPOM2DDN D03 7 (26.5)
Check
Pilot
4 Operator CPOM3DDN D05 12 (45.4)
Check
*Manapak valves mounted in order of callout.
First valve will be nearest DCV; last valve will be on manifold.
Code Function Model Number Technical Data
Return Line Heat Air/Oil: .7 HP (0.52 kW), Rej. @ 7 GPM (26.5 LPM)
B1* RM-08-1-2
Exchanger 0.37 - 3.7 kW Motors only
Return Line Heat Air/Oil: 1.5 HP (1.1 kW), Rej. @ 7 GPM (26.5 LPM)
B2* RM 190-1-2
Exchanger 5.6 - 11.2 kW Motors only
Water/oil: 4hP (3KW)Rej @ 5GPM Oil Flow 1:1 Flow ratio
Return Line Heat
C *^ BS-401-A4-O-BR Max oil Flow 10GPM
Exchanger
Includes 3/4" weld coupling for customer supplied device
65253 + bulbwell
If ordered without option C this option will only include
E^ Water Valve/bulbwell + 3/4" weld
the 3/4" weld coupling.
coupling
Microglass II Element, Vis. Ind. - 50 PSI (3.49 bar)
H Pressure Filter 15P110QXRS
Bypass - 4 PSI (0.27 bar), Diff. @ 7 GPM (26.5 LPM)
J 2" Weld coupling for customer supplied heater
Check Valve 5 PSI (0.34 bar) Cracking Pressure
K “DT” & “C” Series
Pump Outlet 25 PSI (1.72 bar) Diff. @ 15 GPM (56.8 LPM)
Bypass Check
L C1220S65 (65 PSI) 4.5 bar Cracking Pressure
(on Heat Exch)
MICROGLASS ii Element, Vis 25PSI (1.72Bar) Indicator
N Return Filter 40CN110B
3PSI (0.21Bar) Diff. @ 7GPM (26.5LPM)
12AT10C Cellulose Element,
O Return Filter
12 GPM (45 LPM) Ind. Gage - 15 PSI (1.03 bar) Bypass
Combination
Fixed Temp at 65°C (149°F)
R1 Float/Temp. Switch 876782-01
Close @ Low Level and/or 65°C (149°F) (N.O.)
N.O. Float Up
Combination
Fixed Temp at 65°C (149°F)
R2 Float/Temp. Switch 876782-02
Open @ Low Level and/or 65°C (149°F) (N.C.) = Omit if not required
Float Up
*Heat rejection based on flow given with a 40°F differential between transfer medium.
^ May require longer than standard lead time.
Parker Hannifin Corporation
Hydraulic Pump and
Power Systems Division 7
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
H-Paks Ordering Information H-Paks

From H-Pak
Options &
Accessories

DCP Inverter Control Voltage


Drive Configuraton (3 Phase)

Code Configuration
Omit End of Model Code
AC10 Drive configured per the
\
following selections
DCP Option Not Available on 1/2 & 1 Hp Units

Code Configuration Description


Unit will be configured to operate 500-2000 RPM from a
I Analog Speed Control (4-20mA)
4-20mA input signal
Unit will be configured to operate 500-2000 RPM from a
V Analog Speed Control (0-10VDC)
0-10VDC input signal
Unit will be configured to operate at 8 discrete speeds
D Discrete Speed Control (3 inputs)
based on combination of 3 inputs.
Unit will run at 1800 RPM until motor torque Reaches
Q 2 Speeds Based on Torque
85% of NOM, them will go to 600 RPM.
Unit will be configured to run at 1800 RPM with a 2 sec
S Soft Start
accel ramp (0 to 1800 RPM in 2 secs)

Code Configuration Description


2* Incoming Power 230VAC 3 Phase 220-240V +/-15%
4 Incoming Power 460VAC 3 Phase 380-480V +/-10%/-15%
*Only available for 2Hp & 3Hp Drives
Consult factory for single phase applications

Sample Model Code


H36.3NOPHKN\ V4
Incoming Power 460VAC 3 Phase
Voltage Control Option
Include DCP Option

HP Voltage Hp/Voltage AC 10 Part Numbers


2 Incoming Power 230VAC 3 Phase 16G-31-0070-BF-DT
2
4 Incoming Power 460VAC 3 Phase 16G-41-0040-BF-DT
2 Incoming Power 230VAC 3 Phase 16G-31-0100-BF-DT
3
4 Incoming Power 460VAC 3 Phase 16G-41-0065-BF-DT
5 4 Incoming Power 460VAC 3 Phase 16G-41-0090-BF-DT
7.5 4 Incoming Power 460VAC 3 Phase 16G-42-0120-BF-DT
10 4 Incoming Power 460VAC 3 Phase 16G-42-0170-BF-DT
15 4 Incoming Power 460VAC 3 Phase 16G-43-0230-BF-DT
20 4 Incoming Power 460VAC 3 Phase 16G-43-0320-BF-DT

Parker Hannifin Corporation


Hydraulic Pump and
8 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
V-Paks Ordering Information V-Paks

OR Reduced
Flow

Reservoir Pressure Pump Control Pump Flow D = Dual Rated• Electric Manifold
Control W = No Motor•• Motor

Reservoir Size If No Motor or Electric Motor Description


Code Code
Gallons (Liters) Dual Rated HP (KW) - RPM Frame Phase
V1* 10 (37.9) W G 56C (no motor)

V2 20 (75.7) D G 2 (1.5)-1725 - 56C-3 DUAL RATED

V3 30 (113.6) D K 3 (2.2) - 1725-182TC DUAL RATED

V4 40 (151.4) W L 182TC/184TC (no motor)

*Available up to 10 HP (7.5 kW) motor only. L 5 (3.75) - 1725 - 184TC - 3


D L 5 (3.75) - 1725 - 184TC - 3 DUAL RATED
Code Pressure Control
W M 213TC (no motor)
Omit Single Pressure Remote Compensator
M 7.5 (5.6) - 1725 - 213TC - 3
Single Pressure Remote Compensator with Low Pressure
B D M 7.5 (5.6) - 1725 - 213TC - 3 DUAL RATED
Standby
Single Pressure Remote Compensator with Low Pressure W N 215TC (no motor)
BJ
Standby, 24 VDC N 10 (7.5) - 1725 - 215TC - 3
C Bi-Pressure Remote Compensator D N 10 (7.5) - 1725 - 215TC - 3 DUAL RATED
CJ Bi-Pressure Remote Compensator, 24VDC W P† 254TC (no motor)
Bi-Pressure Remote Compensator with Low Pressure P† 15 (11.2) - 1725 - 254TC - 3
D
Standby
D P† 15 (11.2) - 1725 - 254TC - 3 DUAL RATED
Bi-Pressure Remote Compensator with Low Pressure
DJ W S† 256TC (no motor)
Standby, 24VDC
F Provision for Customer Supplied Remote Control Relief Valve S† 20 (14.9) - 1725 - 256TC - 3
D S† 20 (14.9) - 1725 - 256TC - 3 DUAL RATED
Code Pump Control Single phase electric motors are rated as follows:
Omit Std. Remote Compensator 115/230V, 1PH, TEFC - 60 Hertz 1800 RPM

Load Sense Three phase electric motors are rated as follows:


A* 208-230/460V, 3PH, TEFC - 60 Hertz 1800 RPM 1.15 SF
Flow Control
• Dual rated motors include the 60Hz ratings plus 190/380V 50Hz (1.0SF)
H** Horsepower Limiting 1450RPM 10:1CT/20:1VT INVERTER RATED UR/CSA/CSA EEV/CE.
*A_SAE-6 sense port line will be supplied in topplate. 2Hp & 3Hp S.F.=1.15
** Horsepower setting will be at max. flow & pressure obtainable • Dual rated motors except 2Hp & 3Hp may have longer than standard
with motor selected. Lead time is four weeks for shaded items. leadtime. Options G & K are dual rated as standard.
Consult factory for other motor speeds (RPM) and voltages.
Pump Flow Rate †Available with V2, V3 and V4 tanks only.
Code Pump Used and Description
@1800 RPM •• Use W prefix when no motor is required on unit.
7 7 GPM (29.5 LPM) PVP16 - Std. Remote Compensator When ordering, W must be followed by motor model code equivalent to
frame size of motor to be used.
* Specify in GPM Destroked Max. Volume – 2 GPM Min.
DO NOT USE “W” and “D” together I.E: 182/184TC unit with no motor is
15 15.6 GPM (59 LPM) PVP33 - Std. Remote Compensator called out “WL”.
** Specify in GPM Destroked Max. Volume – 8 GPM Min.
Supply/Return
*Unless otherwise specified, units are shipped at max. flow rate 7.8 GPM Porting Block/Subplate
Code Port or Other
(29.5 LPM) at 1800 RPM. When reduced flow setting is required, specify or Manifold Type
Actuator Port Size
pump setting in .5 GPM (1.9 LPM) increments. Example: 5, 5.5, 6, 6.5
with a 2 GPM (7.6 LPM) minimum flow. Pressure and Return Port P & T Ports Convertible to
O
**Unless otherwise specified, units are shipped at max. flow rate 15.6 Block with Safety Relief Valve SAE-10 Str. Thr'd S5 Option
GPM (59 LPM) at 1800 RPM. When reduced flow setting is required,
D03 Single Station Subplate A & B Ports Spare P & T
specify pump setting in .5 GPM (1.9 LPM) increments. Example: 11, S3
with Safety Relief Valve SAE-8 Str. Thr'd SAE-10 Ports
11.5, 12, 12.5 with a 8 GPM (30.3 LPM) minimum flow.
D05 Single Station Subplate A & B Ports Spare P & T
S5
Example: V*12**-- = Std. Pump Destroked to 12 GPM (45.4 LPM) with Safety Relief Valve SAE-10 Str. Thr'd SAE-12 Ports
V*A11.5**-- = Load Sense Pump Destroked to 11.5 GPM
D03 Multistation Parallel
(43.5 LPM) M33 A & B Ports Spare G Port
Circuit Manifold with Safety
M35 SAE-8 Str. Thr'd SAE-6
Relief Valve
D05 Multistation Parallel
M53 A & B Ports Spare G Port
Circuit Manifold with Safety
= Omit if not required M55 SAE-8 Str. Thr'd SAE-6
Relief Valve
Manifolds are mounted vertically. Bottom station is number 1.
Parker Hannifin Corporation
Hydraulic Pump and
Power Systems Division 9
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
V-Paks Ordering Information V-Paks

P
Directional Manapak Options
Control Valve Control Valves• and
Accessories

Directional
NFPA Nominal Flow
Code Control Valve Description Circuit Symbol
Mounting Pad GPM (LPM)
Model Number
Double AB

B D1VW001CN*** D03 7 (26.5)


(Spr. Ctr) PT

Double AB

C D1VW004CN*** D03 7 (26.5)


(Spr. Ctr) PT

Double AB

F D3W1CN** D05 20 (75.7)


(Spr. Ctr) PT

Double AB

G D3W4CN** D05 15 (56.8)


(Spr. Ctr) PT

Units less valves wil be supplied with station cover plates installed.

NFPA
Manapak Control Valve Model Nominal Flow
Code Mounting Circuit Symbol
Valves Function Number GPM (LPM)
Pad
Flow
1 FM2DDKN D03 7 (26.5)
Control
Flow
2 FM3DDKN D05 12 (45.4)
Control
Pilot Operator
3 CPOM2DDN D03 7 (26.5)
Check
Pilot Operator
4 CPOM3DDN D05 12 (45.4)
Check
*Manapak valves mounted in order of callout.
First valve will be nearest DCV; last valve will be on manifold.

Options and Accessories


Code
Function Model Number Technical Data
Air/Oil: .7Hp (.52KW) Rej @ .5GPM (1.9LPM)
A* Pump Case Heat Exchanger RM-08-4-2
2-15Hp(1.5 -11.2KW) Motors only
Air/Oil: .7Hp (.52KW) Rej @ 7GPM (26.5LPM)
B1* Return Line Heat Exchanger RM-08-1-2
0.37 -3.7KW Motors only
Air/Oil: 1.5Hp (1.1KW) Rej @ 7GPM (26.5LPM)
B2* Return Line Heat Exchanger RM 190-1-2
5.6 -14.9 KW Motors only
Water/oil: 4Hp (3KW)Rej @ 5GPM Oil Flow 1:1 Flow ratio
C*^ Return Line Heat Exchanger BS-401-A4-O-BR Max oil Flow 10GPM
Includes 3/4" weld coupling for customer supplied device
Water/oil: 7Hp (5.2KW)Rej @ 15GPM Oil Flow 2:1 Flow ratio
D*^ Return Line Heat Exchanger BS-701-B6-F-BR Max oil Flow 29GPM
Includes 3/4" weld coupling for customer supplied device
65253 + bulbwell
If ordered without options C or D this option will only include
E^ Water valve/bulbwell + 3/4" weld
the 3/4" weld coupling.
coupling
Microglass II Element, Vis. Ind. - 50 PSI (3.49 bar)
H Pressure Filter 15P110QXRS
Bypass - 4 PSI (0.27 bar), Diff. @ 7 GPM (26.5 LPM)
J 2" Weld coupling for customer supplied heater
Check Valve 5 PSI (0.34 bar) Cracking Pressure
K “DT” & “C” Series
Pump Outlet 25 PSI (1.72 bar) Diff. @ 15 GPM (56.8 LPM)
Bypass Check
L C1220S65 (65 PSI) 4.5 bar Cracking Pressure
(on Heat Exch)
Microglass II Element, Visual 25 PSI (1.72 bar) Indicator
N Return Filter 40CN110B
3 PSI (0.21 bar) Diff. @ 7 GPM (26.5 LPM) *Heat rejection based on
12AT10C Cellulose Element, 40°F differential between
O Return Filter transfer medium.
12 GPM (45 LPM) Ind. Gage - 15 PSI (1.03 bar) Bypass
^ May require longer than
Combination Float/Temp. Switch Fixed Temp at 65°C (149°F) standard lead time.
R1 876782-01
N.O. Float Up Close @ Low Level and/or 65°C (149°F) (N.O.)
Combination Float/Temp. Switch Fixed Temp at 65°C (149°F)
R2 876782-02 = Omit if not required
Float Up Open @ Low Level and/or 65°C (149°F) (N.C.)
Parker Hannifin Corporation
Hydraulic Pump and
10 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Installation Information
Catalog HY28-2661-CD/US Vertical Power Units Series H, V-Packs
Installation Information VolumeD-Paks
Series Control

Dimensions – Basic D-Pak (18.9 Liter (5 Gallon) Tank)


Inch equivalents for millimeter dimensions are shown in (**). Filter Option Reference
SPARE RETURN PORT
1/2" NPTF
WITH DROP PIPE
Motor Code Motor Size Dimension “B”
U1, T1, T3, DG 56C Frame 0"

DK 182TC Frame 19.1 (.75)

381 (15.00 )
19.1 (.75 )
343 (13.50 )
"B" 318 (12.50 ) T

.56 DIA. MOUNTING


HOLES - 4 PLACES

331 SPARE RETURN PORT


(13.00) 1/2" NPTF WITH
318
DROP PIPE “O” & “S3” OPTION MANIFOLD
(12.50) (P & T BLOCK & D03 SINGLE STATION)
ELECTRIC MOTOR
254 SHOWN WITH OPTION “O” RETURN FILTER
(10.00)
31.8
(1.25)

SYSTEM RELIEF VALVE


23 (.90 )
16.8 (.66 )

B A
“O” & “S3” OPTION MANIFOLD
(P & T BLOCK & D03 SINGLE STATION)
BASIC UNIT

PRESSURE GAGE
WITH NEEDLE VALVE
SPARE RETURN PORT
1/2" NPTF
WITH DROP PIPE
“O” (“P” & “T” BLOCK)
OR “S3” (“D03” SUBPLATE)
“A” * SHOWN-SEE MANIFOLD OPTIONS
B A FILLER
BREATHER

OIL LEVEL
SIGHT GAGE
T
263.1
(10.36) TANK DRAIN
SAE-12 (PLUGGED)
38.1
(1.5)

307.9 3.1 “M3*” & "C3*" OPTION MANIFOLD


(12.12) (.12) (MULTI-STATION D03 MANIFOLD)
SHOWN WITH OPTION “O” RETURN FILTER
Motor Motor Description Dimension
Code KW(HP)-RPM-Frame-Phase “A” *

B A

B A

* Reference dimension consult factory if critical to application.

13 Parker Hannifin Corporation


Hydraulic Pump Division
Maryville, Ohio USA
Parker Hannifin Corporation
Hydraulic Pump and
Power Systems Division 11
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Installation Information
Catalog HY28-2661-CD/US Vertical Power Units Series H, V-Packs
Installation Information VolumeH,
Series Control
V-Paks

Dimensions – Basic H1 & V1 Filter Option Reference


(10 Gallon Tank) SPARE RETURN PORT
3/4" NPTF
WITH DROP PIPE
Inch equivalents for millimeter dimensions are shown in (**).
482.6 (19.00)
19.1 444.5 (17.50)
(.75) 422.4 (16.63)

33.3
“B” (1.31)
.56 DIA. MOUNTING
HOLES - 4 PLACES

SPARE RETURN PORT


3/4" NPTF WITH
DROP PIPE

T
ELECTRIC MOTOR

P
355.6
(14.00)

“O” & “S5” OPTION MANIFOLD


422.4 (P & T BLOCK & D05 SINGLE STATION)
(16.63) SYSTEM RELIEF VALVE
FOR H-PAKS SHOWN WITH OPTION “O” RETURN FILTER
T

SAFETY RELIEF VALVE


P

FOR V-PAKS

22.9 PUMP COMPENSATOR CONTROL


(.9) FOR V-PAKS
(NOT INCLUDED ON H-PAKS)
“O” & “S5” OPTION MANIFOLD
(P & T BLOCK & D05 SINGLE STATION)
BASIC UNIT
ROTATION ARROW

PRESSURE GAGE A-D03


WITH NEEDLE VALVE
B-D03
B-D05 A-D05

“O” (“P” & “T” BLOCK)


“A” * OR “S5” (“D05” SUBPLATE)
SHOWN-SEE MANIFOLD OPTIONS
FILLER
BREATHER
SPARE RETURN PORT
A-D03 B-D03
3/4" NPTF
B-D05 A-D05
WITH DROP PIPE

OIL LEVEL
SIGHT GAGE

390.1 TANK DRAIN


(15.36) SAE-12 (PLUGGED)

38.1
T

(1.5)
P

409.5 3.1
(16.12) (.12)
“M5*” OPTION MANIFOLD
(MULTI-STATION D05 MANIFOLD)
SHOWN WITH OPTION “O” RETURN FILTER
Code KW(HP)-RPM-Frame-Phase

B A

B A

* Reference dimension consult factory if critical to application.

14 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USAHydraulic Pump and
12 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Installation
Catalog Information
HY28-2661-CD/US
Catalog HY28-2661-CD/US Vertical Power
VerticalUnits
Power Units Series D, H, V-Packs
Installation
Installation
Information
Information Volume Control
Volume
Series H,Series
V-Paks Control
H, V-Paks

Dimensions
Dimensions
– Basic–H2,Basic
3, 4H2,
& V2,
3, 43,&4 V2, 3, 4 Filter Option
FilterReference
Option Reference
(20, 30, (20,
40 Gallon
30, 40 Tank)
Gallon Tank) SPARE RETURNSPARE
PORT RETURN PORT
3/4" NPTF 3/4" NPTF
Inch equivalents
Inch equivalents
for millimeter
for dimensions
millimeter dimensions
are shown are
in (**).
shown in (**). WITH DROP PIPE
WITH DROP PIPE

571.5 (22.5) 571.5 (22.5)


533.4 (21.0) 533.4 (21.0)
508.0 (20.0) 508.0 (20.0) OUT OUT

38.1 38.1
“B” (1.5) “B” (1.5)
.56 DIA. MOUNTING
.56 DIA. MOUNTING IN IN
HOLES - 4 PLACES
HOLES - 4 PLACES

SPARE RETURNSPARE
PORT RETURN PORT
3/4" NPTF WITH3/4" NPTF WITH
DROP PIPE DROP PIPE
431.8 431.8
(17.0) (17.0) ELECTRIC MOTOR
ELECTRIC MOTOR

T
508.0 508.0 PUMP PREFILL PUMP
PORT PREFILL PORT

P
(20.0) (20.0) FOR V-PAKS (8-15
FORGPM
V-PAKS
ONLY)
(8-15 GPM ONLY)

“O” & “S5” OPTION


“O” & “S5”
MANIFOLD
OPTION MANIFOLD
SYSTEM RELIEFSYSTEM
VALVE RELIEF VALVE (P & T BLOCK(P&&D05
T BLOCK
SINGLE& D05
STATION)
SINGLE STATION)
FOR H-PAKS FOR H-PAKS
T

SHOWN WITH SHOWN


OPTION WITH
“N” RETURN
OPTION “N”
FILTER
RETURN FILTER
SAFETY RELIEFSAFETY
VALVE RELIEF VALVE
P

FOR V-PAKS FOR V-PAKS

PUMP COMPENSATOR
PUMP COMPENSATOR
CONTROL CONTROL
22.9 22.9 FOR V-PAKS FOR V-PAKS
(.9) “O” (.9)
& “S5” OPTION
“O” & “S5”
MANIFOLD
OPTION MANIFOLD
(NOT INCLUDED(NOT
ON H-PAKS)
INCLUDED ON H-PAKS)
(P & T BLOCK(P&&D05
T BLOCK
SINGLE& D05
STATION)
SINGLE STATION)
BASIC UNIT BASIC UNIT
ROTATION ARROW
ROTATION ARROW

PRESSURE GAGEPRESSURE GAGE


WITH NEEDLE VALVE
WITH NEEDLE VALVE
A-D03 B-D03 A-D03 B-D03
B-D05 A-D05 B-D05 A-D05
“O” (“P” & “T” BLOCK)
“O” (“P” & “T” BLOCK)
OR “S5” (“D05” SUBPLATE)
OR “S5” (“D05” SUBPLATE)
“A” * “A” * SHOWN-SEE MANIFOLD
SHOWN-SEE OPTIONS
MANIFOLD OPTIONS

FILLER FILLER
BREATHER BREATHER

A-D03
B-D05
B-D03
A-D05
A-D03
B-D05
B-D03
A-D05
LIFT EYES - 2 PLACES
LIFT EYES - 2 PLACES

SPARE RETURNSPARE
PORT RETURN PORT
3/4" NPTF 3/4" NPTF
WITH DROP PIPE
WITH DROP PIPE
OIL LEVEL OIL LEVEL
SIGHT GAGE SIGHT GAGE
OUT OUT

TANK DRAIN TANK DRAIN


“C” “C” SAE-12 (PLUGGED)
SAE-12 (PLUGGED)
IN IN

38.1 38.1
(1.5) (1.5)
T

495.3 495.3 3.1 3.1


P

(19.5) (19.5) (.12) (.12)

Motor Motor
Motor
Description
Motor DescriptionDimension Dimension
“M5*” OPTION
“M5*”
MANIFOLD
OPTION MANIFOLD
Code
Motor CodeMotorKW(HP)-RPM-Frame-Phase
Description
KW(HP)-RPM-Frame-Phase “A” * Dimension
“A”
“B”
* “B” (MULTI-STATION
(MULTI-STATION
D05 MANIFOLD)
D05 MANIFOLD)
Code KW(HP)-RPM-Frame-Phase
U1 .37(.5)U1 .37(.5) -1725-56C-1
-1725-56C-1 266.70 (10.50)266.70
“A”* (10.50)
19.05 19.05 (.75)
(.75) “B” SHOWN WITHSHOWN
OPTIONWITH
“N” RETURN
OPTION “N”
FILTER
RETURN FILTER
C1
U1 .56(.75) C1 .56(.75) -1725-56C-1
-1725-56C-1
.37(.5) -1725-56C-1 279.40
279.40 (11.00)
266.70 (11.00)
19.05
(10.50) (.75) 19.05 (.75)
19.05 (.75)
T1
C1 .75(1)T1
.56(.75) .75(1) -1725-56C-1
-1725-56C-1
-1725-56C-1 298.45
298.45 (11.75)
279.40 .75 (11.75)
(19.05)
(11.00) .75 (19.05)
19.05 (.75)
T3 .75(1)T3 .75(1) -1725-56C-3
-1725-56C-3 266.70 (10.50)266.70 (10.50)
19.05 (.75) 19.05 (.75)
T1 .75(1) -1725-56C-1 298.45 (11.75) .75 (19.05)
F 1.1(1.5)F-1725-56C-3
1.1(1.5) -1725-56C-3
273.05 (10.75)273.05 (10.75)
19.05 (.75) 19.05 (.75)
T3 .75(1) -1725-56C-3 266.70 (10.50) 19.05Reservoir
(.75)
G 1.5(2)G-1725-56C-3 1.5(2) -1725-56C-3
298.45 (11.75)298.45 (.75) 19.05 (.75) Reservoir
(11.75)
19.05 Reservoir Dimension
Reservoir Dimension
DG 2 (1.5)-1725 - 56C-3 DUAL RATED 359 (14.1) Code
19.05 (.75) Size
Code “C”
Size “C”
K 2.2(3)K-1725-56C-3 2.2(3) -1725-56C-3
320.55 (12.62)320.55 (12.62)
19.05 (.75) 19.05 (.75)
Reservoir
151.4 LitersReservoir
151.4
491.74 Dimension
Liters 491.74
DK 3 (2.2) - 1725-182TC DUAL RATED 435 (17.1) 19.05 (.75)
L 3.7(5)L-1725-184TC-3
3.7(5) -1725-184TC-3
365.25 (14.38)365.25
28.70(14.38)
(1.13) 28.70
H2 or(1.13)
V2 Code H2 or V2Code “C”
(20 Gal) (19.36)
(20 Gal) (19.36)
B A B A

ML 5 (3.75) M
5.6(7.5) 1725 - 5.6(7.5)
184TC - 3-1725-213TC-3
- -1725-213TC-3 435406.40
406.40 (16.00) 35.05
(17.1) (16.00)
28.7035.05
(1.38) (1.13) (1.38)
H2113.6
or V2 Liters
151.4 Liters 491.74
G G

113.6
599.95Liters 599.95
H3 or V3 H3 or V3 (19.36)
(1.38) (1.38) (30 Gal) (20 Gal)
B A B A

NM 7.5 (5.6)N
7.5(10) 1725 - 7.5(10)
213TC - -1725-215TC-3
--1725-215TC-3 458413.51
3 413.51 (16.28) 35.05
(18) (16.28)
35.0535.05
(1.38) (23.62)
(30 Gal) (23.62)
PN 10 (7.5) -P-1725-254TC-3
11.2(15) 1725 -11.2(15)
215TC - 3-1725-254TC-3 473447.80
447.80 (17.63) 85.09
(18.6) (17.63)
35.0585.09
(3.35) (1.38) (3.35)
H375.7
or V3 Liters
113.6 Liters
75.7
733.04 599.95733.04
Liters
H4 or V4 H4 or V4
S 14.9(20)S-1725-256TC-3
14.9(20) -1725-256TC-3
492.25 (19.3) 492.25 (3.35) 85.09 (3.35) (40 Gal) (30 Gal)
85.09(19.3) (40 Gal)(23.62)(28.86)
(28.86)
P 15 (11.2) - 1725 - 254TC - 3 522 (20.5) 85.09 (3.35)
* Reference dimension
* Reference
consult
dimension
factory consult
if criticalfactory
to application.
if critical to application. H4 or V4 75.7 Liters 733.04
S 20 (14.9) - 1725 - 256TC - 3 DUAL RATED 522 (20.5) 85.09 (3.35) (40 Gal) (28.86)

15 15 Parker Hannifin
Parker
Corporation
Hannifin Corporation
Parker Hannifin Corporation Hydraulic PumpHydraulic
DivisionPump Division
Hydraulic Pump and Maryville, Ohio
Maryville,
USA Ohio USA
Power Systems Division 13
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information
Catalog HY28-2661-CD/US Vertical Power Units Series D, H, V-Packs
Technical Information VolumeD,
Series Control
H, V-Paks

Manifold Options
Inch equivalents for millimeter dimensions are shown in (**).

SUPPLY RETURN SUPPLY RETURN


PORT PORT PORT PORT
SAE-10 SAE-10 SAE-10 SAE-10

X
RETURN P T “A” RETURN P T “A”
PORT X P A X PORT PORT X P A PORT
SAE-10 SAE-8 SAE-10 SAE-8

T B
“B” T TB
“B” T
X PORT PORT
D03 SAE-8 D03 SAE-8
87.4 P P
COVER (3.44) 52.3 MNTG
PLATE SURFACE
(2.06) 31.8
(1.25)

44.2
PUMP (1.75) PUMP
SUPPLY SUPPLY

B A B A

85.9
(3.38) 47.8
(1.88)

22.0 44.5
(.87) (1.75)

O S3

MANIFOLD OPTION SUBPLATE OPTION


FOR SUPPLY & RETURN CONNECTIONS FOR USE WITH D1VW VALVE
(18.9 LITER (5 GAL.) RESERVOIR UNITS) (NFPA D03)

SUPPLY RETURN SUPPLY RETURN


PORT PORT PORT PORT
SAE-12 SAE-12 SAE-12 SAE-12
X

RETURN P T “A” RETURN P T “A”


PORT X P A X PORT PORT X P A PORT
SAE-12 SAE-10 SAE-12 SAE-10
“B” “B”
T

T B X PORT T
B
44.5 PORT
D05 SAE-10 (1.75) D05 SAE-10
COVER MNTG
P

PLATE 53.8 SURFACE


RETURN (2.12) RETURN 31.8
PORT X PORT X (1.25)
SAE-12 SAE-12
44.5
PUMP (1.75) PUMP
SUPPLY SUPPLY

A-D03 B-D03 A-D03 B-D03


B-D05 A-D05 B-D05 A-D05
104.6
(4.12)
38.1
(1.50)

17.5 53.8
(.69) (2.12)

O S5
MANIFOLD OPTION
FOR SUPPLY & RETURN CONNECTIONS SUBPLATE OPTION
(37.9, 75.7, 113.6, 115.4 LIT FOR USE WITH D3W VALVE
(10, 20, 30, 40 GAL) RESERVOIR UNITS) (NFPA D05)

16 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USAHydraulic Pump and
14 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information
Catalog HY28-2661-CD/US Vertical Power Units Series D, H, V-Packs
Technical Information VolumeD,
Series Control
H, V-Paks

Manifold Options
Inch equivalents for millimeter dimensions are shown in (**).

RETURN
PORT
Option M33/M35 SAE-10

X
P T
A

3 AND 5 STATIONS)
"A"&"B"PORTS
B

SAE-8

T
A

G B
"G"
SAE-6 D03
MNTG
SURFACE
33.3
(1.31)
PUMP
SUPPLY
54.0
(2.12)
PER STATION

3 AND 5 B A
STATION
G
AVAIL. 54.0
4.25 B A (2.12)

22.1 1.06
(0.87)
44.5
(1.75)

M33 AND M35

3 AND 5 STATION MANIFOLD OPTIONS

FOR USE WITH NFPA D03 VALVES

RETURN
Option M53/M55 PORT
SAE-12
X

P T
A
3 AND 5 STATIONS
"A"&"B"PORTS

B
SAE-8

A
P

G B
"G"
SAE-6 D05
MNTG
SURFACE 31.8
(1.25)
PUMP
SUPPLY

82.6 (3.25)
PER STATION

3 AND 5 B A
STATION
AVAIL.
165.1 G 82.6
(6.50) (3.25)
B A

39.6
17.5 (1.56)
(0.69)
54.0
(2.12)

M53 AND M55

3 AND 5 STATION MANIFOLD OPTIONS

FOR USE WITH NFPA D05 VALVES

17 Parker Hannifin Corporation


Parker Hannifin Corporation Hydraulic Pump Division
Hydraulic Pump and Maryville, Ohio USA
Power Systems Division 15
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information
Catalog HY28-2661-CD/US Vertical Power Units Series D, H, V-Packs
Technical Information Series DControl
Volume , H, V-Paks

Pressure Control Option "B" – Unloading Valve

T T

INVERTED

INVERTED
UPRIGHT

UPRIGHT
P

B A

B A G

B A

"H"PAK WITH "H"PAK WITH


"S3" MANIFOLD "M3*" MANIFOLD
3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY 3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY
(CONNECTED TO SYSTEM RETURN LINE) (CONNECTED TO SYSTEM RETURN LINE)

A-D03 B-D03 A-D03 B-D03


B-D05 A-D05 B-D05 A-D05

"H"PAK WITH "H"PAK WITH


"OMIT","S5","S6","M5*","M6*" MANIFOLDS "OMIT","S3","S5","S6","M3*","M5*","M6*" MANIFOLDS
3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY 23.84-46.56 LPM (6.3-12.3 GPM) FLOW RATES ONLY
(PLUMBED DIRECTLY BACK TO TANK) (PLUMBED DIRECTLY BACK TO TANK)

18 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USAHydraulic Pump and
16 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information
Catalog HY28-2661-CD/US
Catalog HY28-2661-CD/US Vertical Power
Vertical Power Units
Units Series D, H, V-Packs
Te
Tec
ch
hn
niic
caall IIn
nffo
orrm
maattiio
onn Volume
Volume
S
Seerriie
essDControl
Control
D,, H
H,, V
V--P
Pa
akks
s

Pressure Control
Pressure Control Option
Option "B"
"B"–Unloading Valve
– Unloading Valve

T T T T

INVERTED

INVERTED

INVERTED
INVERTED

UPRIGHT

UPRIGHT
UPRIGHT

UPRIGHT
P P

B A B A

B A B A G G

B A B A

"D"PAK WITH "D"PAK WITH


"H"PAK WITH
"S3" MANIFOLD "M3*" MANIFOLD
"H"PAK WITH
(CONNECTED TO"S3" MANIFOLD
SYSTEM RETURN (CONNECTED TO SYSTEM RETURN
"M3*" MANIFOLD
3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY 3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY
(CONNECTED TO SYSTEM RETURN LINE) (CONNECTED TO SYSTEM RETURN LINE)

T
INVERTED
UPRIGHT

A-D03 B-D03 A-D03 B-D03


B-D05 A-D05 B-D05 A-D05

B A

"D"PAK WITH
"H"PAK WITH "OMIT" MANIFOLD "H"PAK WITH
"OMIT","S3","S5","S6","M3*","M5*","M6*" MANIFOLDS
"OMIT","S5","S6","M5*","M6*" MANIFOLDS (CONNECTED TO SYSTEM RETURN
3.4-19.3 LPM (0.9-5.1 GPM) FLOW RATES ONLY 23.84-46.56 LPM (6.3-12.3 GPM) FLOW RATES ONLY
(PLUMBED DIRECTLY BACK TO TANK) (PLUMBED DIRECTLY BACK TO TANK)

19
18 Parker Hannifin
Parker Hannifin Corporation
Corporation
Parker Hannifin Corporation Hydraulic Pump
Hydraulic Pump Division
Division
Hydraulic Pump and Maryville, Ohio USA
Maryville, Ohio USA
Power Systems Division 17
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information
Catalog HY28-2661-CD/US Vertical Power Units Series V-Packs
Technical Information VolumeV-Paks
Series Control

V-Pak – Compensator Options


“OMIT” OPTION “B” OPTION T
SINGLE PRESSURE SINGLE PRESSURE HIGH LOW
PSI PSI LOW SOL
REMOTE COMPENSATOR REMOTE COMPENSATOR STANDBY
W/LOW PRESS. STANDBY

P T HIGH
SOL
P
P
SAE
SOLENOID IS LOW WATT
-6 WITH DIN. 43650 CONNECTOR
AND MANUAL OVERRIDE

LOW PRESS. STANDBY (N.O.)


AUX. VENT PORT (SAE-6) ENERGIZE TO BUILD PRESSURE
PUMP COMPENSATOR PUMP COMPENSATOR
CONTROL ADJUSTMENT CONTROL ADJUSTMENT

HI LO
SOL SOL

HI
LO

“C” OPTION T
“D” OPTION T
BI-PRESSURE HIGH LOW BI-PRESSURE HIGH LOW
LOW SOL
REMOTE COMPENSATOR PSI PSI REMOTE COMPENSATOR PSI PSI
STANDBY
W/LOW PRESS. STANDBY

HIGH HIGH
SOL SOL
P P

SOLENOID IS LOW WATT SOLENOID IS LOW WATT


WITH DIN. 43650 CONNECTOR WITH DIN. 43650 CONNECTOR
AND MANUAL OVERRIDE AND MANUAL OVERRIDE

HIGH PRESS. SOLENOID (N.O.)


HIGH PRESS. SOLENOID (N.O.) ENERGIZE FOR HIGH PRESSURE
ENERGIZE FOR HIGH PRESSURE
LOW PRESS. STANDBY (N.O.)
PUMP COMPENSATOR ENERGIZE FOR LOW PRESSURE
HIGH PRESS. CONTROL

HI LO HI LO
SOL SOL SOL SOL

HI HI
LO LO

PUMP COMPENSATOR PUMP COMPENSATOR


LOW PRESS. CONTROL HIGH PRESSURE CONTROL
PUMP COMPENSATOR
LOW PRESSURE CONTROL

“F” OPTION
PROVISION FOR
CUSTOMER SUPPLIED
REMOTE COMPENSATOR

SAE -6
37 FLARE
P T

P P

T
T

PUMP COMPENSATOR
PRESSURE (INLET) PORT
PUMP COMPENSATOR
TANK (RETURN) PORT

SAE-6 37 FLARE “P” & “T” PORTS


ATTACH POINTS FOR CUSTOMER
SUPPLIED REMOTE COMPENSATOR

20 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USAHydraulic Pump and
18 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information Series V-Packs

ACCESSORY OPTIONS—D&H PAKS

OPTION B RETURN LINE AIR/OIL HEAT EXCHANGER (B1 OR B2) OPTION L CHECK VALVE–RETURN LINE BYPASS
OPTION C WATER/OIL HEAT EXCHANGER OPTION N RETURN LINE FILTER
OPTION E SYSTEM COOLING/FILTER LOOP OPTION O RETURN LINE FILTER
OPTION H PRESSURE FILTER OPTION R COMBINATION TEMP/LEVEL SWITCH (R1 OR R2)
OPTION J WELD COUPLING FOR HEATER
OPTION K CHECK VALVE–PUMP OUTLET

SEE MANIFOLD
OPTIONS

SAE - 10
SAE - 6

1/2" NPT - “D” PAKS SAE - 10


3/5" NPT - “H” PAKS

SAE - 12 SEE MANIFOLD


OPTIONS

SAE - 10 SEE MANIFOLD


SAE - 6
ACCESSORY OPTIONSPAKS
OPTIONS—V

1/2" NPT - “D” PAKS SAE - 10


OPTION A PUMP CASE HEAT EXCHANGER
3/5" NPT - “H” PAKS SAE - 10 OPTION K CHECK VALVE–PUMP OUTLET
SAE - 6
OPTION B RETURN LINE AIR/OIL HEAT EXCHANGER (B1 OR B2) OPTION L CHECK VALVE–RETURN LINE BYPASS
OPTION C WATER/OIL HEAT EXCHANGER SAE - 10
OPTION N RETURN LINE FILTER
OPTION D WATER/OIL HEAT EXCHANGER OPTION O RETURN LINE FILTER
OPTION E WATER CONTROL VALVE OPTION R COMB. TEMP/LEVEL SWITCH (R1 OR R2)
SEE
OPTION H PRESSURE FILTER COMPENSATOR
OPTION J WELD COUPLING FOR HEATER OPTIONS
SAE - 12

SAE - 12 SEE MANIFOLD


CONNECTED TO RETURN
OPTIONS
LINE WITH OPTION “B1” & “B2”

SAE - 10
SAE - 6

SAE - 10

SEE
COMPENSATOR
OPTIONS

SAE - 12

CONNECTED TO RETURN
LINE WITH OPTION “B1” & “B2”

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 19
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Catalog HY28-2661-CD/US Vertical Power Units
Technical Information Volume Control Series D-Packs
Technical Information Series D-Paks

Dimensions – D-Pak (5 Gallon Tank) Accessories


Inch equivalents for millimeter dimensions are shown in (**). Installation information is for reference only. Consult
factory or visit Parker's Econfigurator for detailed information.

SPARE RETURN PORT


1/2" NPTF WITH DROP PIPE
(NOT SHOWN)

19.8
[0.78]

P
10.8
[0.43]

129.5
[5.1]
OPTION "B1" REF.
AIR/OIL
HEAT EXCHANGER

OPTION "N" OR "O"


RETURN FILTER

16.3
[0.64]

OPTION "R1" OR "R2"


FLOAT/TEMP. SWITCH
(1/2" ELEC. CONN.)
OPTION "H"
DIM PRESSURE FILTER
"A"
REF
B A

Parker Hannifin Corporation


Hydraulic Pump and
20 Power Systems Division
Marysville, Ohio USA

22 Parker Hannifin Corporation


Hydraulic Pump Division
HY28-2661-CD/US
Catalog HY28-2661-CD/US Vertical Power Units Hydraulic Power Units
Catalog HY28-2661-CD/US Vertical
VolumeH, Power Units
Control
Technical
Technical Information
Information Series
Volume V-Paks
Control Series H, V-Packs
Technical Information Series H, V-Paks
Dimensions – H1& V1 (10 Gallon Tank) Accessories
Dimensions – H1& V1 (10 Gallon Tank) Accessories
Inch equivalents for millimeter dimensions are shown in (**). Installation information is for reference only, consult
Inch equivalents
factory for millimeter
or visit Parker's dimensions
Econfigurator are shown
for detailed in (**). Installation information is for reference only, consult
information.
factory or visit Parker's Econfigurator for detailed information.

16.9
[0.67]
16.9
[0.67]

12.7
[0.50]
10.2 12.7
[0.40] [0.50]
10.2
[0.40]
SPARE RETURN PORT
3/4" NPTF
SPAREWITH DROP PIPE
RETURN PORT
3/4" NPTF
WITHOPTION "M", "N", "O" OR "V"
DROP PIPE
RETURN FILTER
OPTION "M", "N", "O" OR "V"
RETURN FILTER

T
T

TP
T

P
P

130
[5.1]
130
OPTION "B1" [5.1] OPTION "A"
AIR/OIL PUMP CASE HEAT EXCHANGER
HEAT EXCHANGER (USED ON "V" PAKS ONLY)
OPTION "B1" OPTION "A"
AIR/OIL PUMP CASE HEAT EXCHANGER
HEAT EXCHANGER (USED ON "V" PAKS ONLY)
26.5
89.7
[1.04] [3.53]
26.5
89.7
[1.04] [3.53]

DIM DIM
"A" "A"
REF OPTION "R1" OR" R2" REF
FLOAT/TEMP. SWITCH
DIM (1/2" ELEC. CONN.) DIM
"A" "A"
REF OPTION "R1" OR" R2" REF
A-D03 B-D03
FLOAT/TEMP.
OPTION "H" SWITCH A-D03 B-D03
B-D05 A-D05 (1/2" ELEC.
PRESSURE FILTERCONN.) B-D05 A-D05

A-D03 B-D03
OPTION "H" A-D03 B-D03
B-D05 A-D05
PRESSURE FILTER B-D05 A-D05

FLOAT 2"
BELOW
LOW LEVEL

FLOAT 2"
BELOW
LOW LEVEL

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 21
23 Parker Hannifin Corporation
Marysville, Ohio USA Hydraulic Pump Division
Maryville, Ohio USA

23 Parker Hannifin Corporation


Hydraulic Pump Division
HY28-2661-CD/US Hydraulic Power Units
Technical Information Series H, V-Packs

Dimensions – H1 & V1 (10 Gallon tank) Accessories (continued)

NOTE: USE FOR REFERENCE ONLY


EXACT DIMENSIONS MAY VARY DEPENDING
ON COMBINATION OF OTHER OPTIONS
SPARE RETURN PORT
3/4" NPTF WITH
DROP TUBE (REF.)

SPARE RETURN PORT


3/4" NPTF WITH
DROP TUBE (REF.)

MANIFOLD DIMENSION “A”


M33 7.6 REF.
M35 11.8 REF.
H1 /V1 WITH S3 MANIFOLD H1 /V1 WITH M3* MANIFOLD
OPTION “C” WATER/OIL HEAT EXCHANGER OPTION “D” WATER/OIL HEAT EXCHANGER
OPTION “N” 40 CN RETURN FILTER OPTION “M” 15 CN / OPTION “O” 12AT RETURN FILTER
(M32 W /15CN SHOWN)

Parker Hannifin Corporation


Hydraulic Pump and
22 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information Series H, V-Packs

Dimensions – H1 & V1 (10 Gallon tank) Accessories (continued)

OPTION “E” WATER MODULATING VALVE WITH “C” HEAT EXCHANGER & 10 GALLON TANK

FRONT OF TANK SIDE OF TANK

IF OPTION “E” ORDERED WITH NO HEAT EXCHANGER


THE UNIT WILL BE SUPPLIED
WITH 3/4" WELD COUPLING ONLY.

3/4" COUPLING FOR WATER


VALVE BULBWELL

BULB WELL WATER MODULATING


VALVE

DRAIN (REF.)

OPTION “E” WATER MODULATING VALVE WITH “D” HEAT EXCHANGER & 10 GALLON TANK

FRONT OF TANK SIDE OF TANK


WATER MODULATING
3/4" NPT 90º VALVE
STREET ELBOW

BULB WELL

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 23
Marysville, Ohio USA
HY28-2661-CD/US
HY28-2661-CD/US Hydraulic Power Units
Technical
Catalog
Techni Information
HY28-2661-CD/US
cal In formation Vertical Power Units Series H, V-Packs
Technical Information VolumeH,
Series Control
V-Paks

Dimensions – H2, 3, 4 & V2, 3, 4 (20, 30,40 Gallon Tank) Accessories


Inch equivalents for millimeter dimensions are shown in (**). Installation information is for reference only. Consult
factory or visit Parker's Econfigurator for detailed information.

105.2
[4.14]

53.5
[2.11] 19.1
[0.75]

OPTION "N" OR "O"


RETURN FILTER

SPARE RETURN PORT


3/4" NPTF
T

T
WITH DROP PIPE
P

P
OPTION "B2"
128.0
AIR/OIL [5.04]
HEAT EXCHANGER OPTION "A"
PUMP CASE HEAT EXCHANGER
(USED ON V-PAKS ONLY)

129.5 124.5
[5.10] [4.90] 89.7
[3.53]

DIM DIM
"A" "A"
REF OPTION "R1" OR "R2" REF
FLOAT/TEMP. SWITCH
(1/2"ELEC. CONN.)

A-D03 B-D03 A-D03 B-D03


B-D05 A-D05 B-D05 A-D05

OPTION "H"
PRESSURE FILTER

FLOAT 2"
BELOW
LOW LEVEL
q

38.0
[1.49]

24 Parker Hannifin Corporation


Parker Hannifin Corporation Parker Hannifin Corporation
Hydraulic Pump Division
Hydraulic Pump Division Maryville, Ohio USAHydraulic Pump and
Marysville, Ohio USA 24
21 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US
HY28-2661-CD/US
HY28-2661-CD/US
Hydraulic
Hydraulic Power
Power
Hydraulic PowerUnits
Units
Units
Technical
Catalog Information
HY28-2661-CD/US Vertical Power
Vertical Units
Power Units Series
Series H, V-Packs
H, V-Packs
Technical
Catalog Information
HY28-2661-CD/US
Volume Control Series H, V-Packs
Technical Information
Technical Information Series H,
Volume
Series V-Paks
Control
H, V-Paks

Dimensions – H2,
Dimensions 3, 43,&4V2,
– H2, 3, 43,(20,
& V2, 30,30,
4 (20, 40 Gallon Tank)
40 Gallon Accessories
Tank) (CONT)
Accessories (CONT)
InchInch
equivalents for millimeter
equivalents dimensions
for millimeter are shown
dimensions in (**).
are shown Installation
in (**). information
Installation is forisreference
information only.only.
for reference Consult
Consult
factory or visit Parker's Econfigurator for detailed information.
factory or visit Parker's Econfigurator for detailed information.

NOTE: USE FDR


NOTE: USE REFERENCE ONLY.
FDR REFERENCE ONLY.
EXACT DIMENSIONS
EXACT MAY VARY
DIMENSIONS DEPENDING
MAY VARY DEPENDING
ON COMBINATION OF OTHER OPTIONS.
ON COMBINATION OF OTHER OPTIONS.

SPARESPARE
RETURN PORT PORT SPARESPARE
RETURN PORT PORT
RETURN
RETURN 3/4" NPTF
3/4" NPTF
3/4"WITH
NPTFDROP
WITH DROP 3/4"WITH
NPTFDROP
WITH DROP
TUBE (REF.) TUBE (REF.)
TUBE (REF.)
TUBE (REF.)

H/VH 2,3,4 WITHWITH


/ V 2,3,4 S3 MANIFOLD
S3 MANIFOLD H/VH 2,3,4 WITHWITH
/ V 2,3,4 S3 MANIFOLD
S3 MANIFOLD
OPTION “C” WATER/OIL
OPTION HEATHEAT
“C” WATER/OIL EXCHANGER
EXCHANGER OPTION “D” WATER/OIL
OPTION HEATHEAT
“D” WATER/OIL EXCHANGER
EXCHANGER
OPTION “N” 40CN
OPTION RETURN
“N” 40CN FILTER
RETURN FILTER OPTION “O” 12AT
OPTION / OPTION
“O” 12AT “M” 15CN
/ OPTION FILTER
“M” 15CN FILTER
(12AT(12AT
FILTER SHOWN)
FILTER SHOWN)

24 24 Parker Hannifin
Parker Corporation
Hannifin Corporation
Hydraulic PumpPump
Hydraulic Division
Division
Parker Hannifin Corporation Maryville, Ohio USA
Maryville, Ohio USA
Hydraulic Pump and 21 21
Power Systems Division 25
Marysville, Ohio USA
HY28-2661-CD/US
HY28-2661-CD/US Hydraulic
HydraulicPower
PowerUnits
Units
Catalog
TechniHY28-2661-CD/US
cal In formation Vertical Power Units Series
SeriesH,
H,V-Packs
V-Packs
Technical Information VolumeH, Control
Technical Information Series V-Paks

Dimensions – H2, 3, 4 & V2, 3, 4 Accessories (CONT)


Inch equivalents for millimeter dimensions are shown in (**). Installation information is for reference only. Consult
factory or visit Parker's Econfigurator for detailed information.

OPTION “E” WATER MODULATING VALVE WITH “C” HEAT EXCHANGER & 20/30/40 GALLON TANK
(20 GALLON TANK SHOWN)

FRONT OF TANK SIDE OF TANK

WATER MODULATING VALVE


1"-3/4" NPT REDUCER

IF OPTION “E” ORDERED WITH NO HEAT


EXCHANGER THE UNIT WILL BE SUPPLIED
WITH 3/4" WELD COUPLING ONLY.

3/4" COUPLING FOR WATER


VALVE BULBWELL

2.65 3/4" NPT NIPPLE, 7" LONG


REF
BULB WELL

1.5" REF
DRAIN (REF.)

OPTION “E” WATER MODULATING VALVE WITH “D” HEAT EXCHANGER & 20/30/40 GALLON TANK

FRONT OF TANK SIDE OF TANK

WATER MODULATING VALVE


3/4" NPT 90•
STREET ELBOW

6.5" REF

4.62" REF
BULB WELL

24 Parker Hannifin Corporation


Hydraulic Pump Division
Maryville, Ohio USA Parker Hannifin Corporation
21 Hydraulic Pump and
26 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information H-Pak with DCP

DCP  PAK  DIMENSIONS  

 
UNITS WILL BE CONFIGURED PER CUSTOMER’S MODEL CODE.
 UNITS ARE TESTED PER CONFIGURATION TO ENSURE PROPER OPERATION.

 *DIMENSION SHOWN IS DEPTH OF THE AC10 AS MEASURED FROM THE MOTOR FEET. REF H PAK DIMENSIONS
EARLIER IN THE CATALOG FOR MORE INFORMATION.
 

   

   

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 27
Marysville, Ohio USA
HY28-2661-CD/US HydraulicPower
Hydraulic PowerUnits
Units
Catalog HY28-2661-CD/US
Technical Information Vertical Power Units SeriesD,
Series D,H,
H,V-Packs
V-Packs
Technical Information VolumeD,
Series Control
H, V-Paks

Performance Data – Maximum Working Pressures


**** Represents maximum operating pressure with pump/motor combination. This will be the maximum relief valve or compensator setting.
**** Represents maximum operating pressure with pump/motor combination. When used on power unit products, the highest relief valve or
compensator setting will be 3000 PSI.

D & H Pak - Pump/Motor Combinations Maximum Operating Pressure Bar (PSI)


Pump Code Motor KW (HP)
Flow at .37 (.5) .60 (.75) .75 (1) 1.1 (1.5) 1.5 (2) 2.2 (3) 3.7 (5) 5.6 (7.5) 7.5 (10) 11.2 (15) 14.9 (20)
1725 RPM Max Operating Pressure (Theoretical)
LPM (GPM)
3.4 (0.9) 55.8(810) 84.1(1220) 111.7(1620) 167.5(2430) 223.4(3240)
4.9 (1.3) 40.0(580) 60.0(870) 80.0(1160) 119.3(1730) 159.3(2310) 239.2(3470)
6.8 (1.8) 29.6(430) 44.1(640) 59.3(860) 88.3(1280) 118.6(1720) 177.2(2570) 275.0(3988)
8.7 (2.3) 22.8(330) 34.5(500) 46.2(670) 69.0(1000) 92.4(1340) 138.6(2010) 231.0(3350)
10.2 (2.7) 20.0(290) 30.3(440) 40.0(580) 60.0(870) 80.7(1170) 120.7(1750) 201.3(2920)
12.1 (3.2) 15.9(230) 24.1(350) 31.7(460) 48.3(700) 64.1(930) 96.5(1400) 160.6(2330) 241.3(3500)
17.0 (4.5) 11.0(160) 17.2(250) 22.8(330) 33.8(490) 45.5(660) 69.0(1000) 115.1(1670) 172.4(2500) 228.9(3320)
19.3 (5.1) 10.3(150) 15.2(220) 20.7(300) 30.3(440) 40.7(590) 61.4(890) 102.0(1480) 153.1(2220) 204.1(2960) 275.0(3988)
23.8 (6.3) 8.3(120) 12.4(180) 16.5(240) 24.8(360) 33.1(480) 49.6(720) 82.7(1200) 124.1(1800) 165.5(2400) 248.2(3600)
30.7 (8.1) 9.7(140) 12.4(180) 18.6(270) 24.8(360) 37.2(540) 62.7(910) 93.8(1360) 125.5(1820) 187.5(2720) 251.0(3640)
35.6 (9.4) 8.3(120) 11.0(160) 16.5(240) 21.4(310) 32.4(470) 53.8(780) 81.4(1180) 108.2(1570) 162.0(2350) 215.8(3130)
46.6 (12.3) 8.3(120) 11.7(170) 15.9(230) 24.1(350) 40.0(580) 60.0(870) 80.0(1160) 120.0(1740) 160.0(2320)

V-Pak - Pump/Motor Combinations Maximum Operating Pressure Bar (PSI)


Motor KW (HP)
Pump LPM (GPM) @ 1725 RPM 1.5 (2) 2.2 (3) 3.7 (5) 5.6 (7.5) 7.5 (10) 11.2 (15) 14.9 (20)
PVP16 7.6 (2.0) 72.4(1050) 108.2(1570) 179.3(2600) 266.1(3860)
PVP16 9.5 (2.5) 64.1(930) 94.5(1370) 155.1(2250) 232.4(3370)
PVP16 11.4 (3.0) 57.2(830) 84.8(1230) 137.9(2000) 206.8(3000)
PVP16 13.2 (3.5) 51.7(750) 75.8(1100) 124.1(1800) 184.8(2680) 246.1(3570)
PVP16 15.1 (4.0) 46.9(680) 68.9(1000) 113.8(1650) 168.2(2440) 223.4(3240)
PVP16 17.0 (4.5) 43.4(630) 63.4(920) 103.4(1500) 153.8(2230) 204.8(2970) 305.4(4430)
PVP16 18.9 (5.0) 40.0(580) 58.6(850) 96.5(1400) 142.0(2060) 188.9(2740) 281.3(4080)
PVP16 20.8 (5.5) 37.9(550) 55.2(800) 89.6(1300) 132.4(1920) 175.1(2540) 261.3(3790)
PVP16 22.7 (6.0) 35.2(510) 51.7(750) 83.4(1210) 123.4(1790) 163.4(2370) 244.1(3540)
PVP16 24.6 (6.5) 33.1(480) 48.3(700) 77.9(1130) 115.8(1680) 153.0(2220) 228.2(3310)
PVP16 26.5 (7.0) 31.0(450) 45.5(660) 73.8(1070) 108.9(1580) 144.8(2100) 215.1(3120)
PVP33 30.3 (8.0) 66.2(960) 97.9(1420) 129.6(1880) 193.1(2800) 255.1(3700)
PVP33 32.2 (8.5) 64.1(930) 93.1(1350) 123.4(1790) 182.7(2650) 242.7(3520)
PVP33 34.1 (9.0) 60.7(880) 88.9(1290) 117.2(1700) 174.4(2530) 231.0(3350)
PVP33 36.0 (9.5) 57.9(840) 84.8(1230) 112.4(1630) 166.2(2410) 220.6(3200)
PVP33 37.9 (10.0) 55.2(800) 81.4(1180) 106.9(1550) 159.3(2310) 206.8(3000)
PVP33 39.7 (10.5) 53.1(770) 77.9(1130) 102.7(1490) 152.4(2210) 202.7(2940)
PVP33 41.6 (11.0) 51.0(740) 75.2(1090) 98.6(1430) 146.9(2130) 194.4(2820)
PVP33 43.5 (11.5) 49.0(710) 72.4(1050) 95.1(1380) 141.3(2050) 186.8(2710)
PVP33 45.4 (12.0) 47.6(690) 69.6(1010) 91.7(1330) 135.8(1970) 180.0(2610)
PVP33 47.3 (12.5) 46.2(670) 66.9(970) 88.3(1280) 131.0(1900) 173.7(2520)
PVP33 49.2 (13.0) 44.8(650) 64.8(940) 85.5(1240) 126.9(1840) 167.5(2430)
PVP33 51.1 (13.5) 43.4(630) 62.7(910) 82.7(1200) 122.7(1780) 162.0(2350)
PVP33 53.0 (14.0) 42.1(610) 60.7(880) 80.0(1160) 118.6(1720) 157.2(2280)
PVP33 54.9 (14.5) 40.7(590) 59.3(860) 77.9(1130) 115.1(1670) 152.4(2210)
PVP33 56.8 (15.0) 39.3(570) 57.2(830) 75.2(1090) 111.7(1620) 147.5(2140)

25 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USA Parker Hannifin
Hydraulic Corporation
Pump Division
Hydraulic
Marysville,Pump and
Ohio USA
22
28 Power Systems Division
28
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Catalog HY28-2661-CD/US Vertical Power Units
Technical Information Volume Control Series D, H, V-Packs
Technical Information Series D, H, V-Paks

Performance Data – Pumps


Standard Pumps
PVP16 @ 1800 RPM PVP33 @ 1800 RPM
LPM GPM Volumetric Efficiency LPM GPM Volumetric Efficiency
100 37.9 10 100 75.7 20
Efficiency - %

90 34.1 9 90 68.2 18

Efficiency - %
Overall Efficiency
Overall Efficiency
80 30.3 8 80 60.6 16
Flow
70 26.5 7 Flow 70 53.0 14

60 22.7 6 60 45.4 12
KW HP KW HP

Flow
Flow

18.9 5 14.9 20.0 50 37.9 10 29.8 40.0

w
15.1 4
w
11.9 16.0 30.3 8 lo 23.9 32.0
lo lF
ll F ul
Fu 22.7 6 atF 17.9 24.0

Power
11.4 3 8.9 12.0
r at Power w er
7.6 2 owe 6.0 8.0 15.1 4 t Po 11.9 16.0
utP pu
In
3.8 1
Inp 3.0 4.0 7.6 2 6.0 8.0
Power wer
Compensated Compensated Po
0 0 0 0 0 0 0 0
Bar 0 69 138 207 275 Bar 0 69 138 207 275
PSI 0 1000 2000 3000 4000 PSI 0 1000 2000 3000 4000
Pressure Pressure
NOTE: The efficiencies and data in the graph are good WHERE:
only for pumps running at 1800 RPM and stroked to Q = Actual Output Flow in GPM
maximum. To calculate approximate horsepower for the
other conditions, use the following formula: PSI = Pressure At Pump Outlet

[ ]
Q x (PSI) N CHp= Input Horsepower @ Full compensation
HP = + (CHp) x @ 1800 RPM (from graph read at
1714 1800
operating pressure)
Actual GPM is directly proportional to drive speed and
maximum volume setting. Flow loss, however, is a N = Drive Speed in RPM
function of pressure only.

Horsepower Limited Pumps

PVP16 @ 1800 RPM PVP33 @ 1800 RPM


8 20
500
E F
Outlet Flow (GPM)

Outlet Flow (GPM)


Input Torque (In.-Lb.)

6 12 15 30
400 1000
B C E
Input Torque (In.-Lb.)

D D
Horsepower HP

Horsepower HP

F 10 25
C A E 800
300
4 8 10 20
B D 600
E
6 200 15
A C
D 400
2 4 5 10
C 100
B B 200
2 5
A A
0 0 0 0 0 0
0 1000 2000 3000 0 1000 2000 3000
Pressure - PSI Pressure - PSI
MOTOR KW (HP) MOTOR KW (HP)
1.5(2) 2.2(3) 3.7(5) 5.6(7.5) 7.5(10) 11.2(15) 5.6(7.5) 7.5(10) 11.2(15) 14.9(20)
Compensator Setting Bar (PSI) Compensator Setting Bar (PSI)
PVP16 110.3 151.7 206.8 206.8 206.8 206.8 PVP33 151.7 186.2 206.8 206.8
FULL STROKE (1600) (2200) (3000) (3000) (3000) (3000) FULL STROKE (2200) (2700) (3000) (3000)
Pump Control Option “H” with PVP16 Pump Control Option “H” with PVP33
Horsepower Limiting Horsepower Limiting
Factory Compensator Settings Factory Compensator Settings

26 Parker Hannifin Corporation


Parker Hannifin Corporation Hydraulic Pump Division
Hydraulic Pump and Maryville, Ohio USA
Power Systems Division 29
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Catalog HY28-2661-CD/US
Technical
Technical Information
Information Vertical Power Units Series D, H, V-Packs
Technical Information VolumeD,
Series Control
H, V-Paks

Performance Data – Heat Exchangers

Air/Oil Heat Exchangers


“A”, “B1” & “B2” used with 1800 RPM TEFC Motors
1.5(2)
Horsepower Re moved

1.1(1.5)
By Cooler KW (HP)

B2

.75(1)
.60(.8)

.45(.6)
A
.37(.5)
.30(.4)
B1* B1
.22(.3)

0 1.14 1.89 3.03 5.68 11.36 18.93 30.28 56.78 94.64


(.3) 1.51 (.5) 2.27 (.8) 3.79 (1.5) 7.57 (3) 15.14 (5) 22.71 (8) 37.85 (15) 75.71 (25)
(.4) (.6) (1) (2) (4) (6) (10) (20)
Oil Pressure Drop
“A” - Pump Case HT. EX. with 56C-256TC Motors
Oil Flow - LPM (GPM) at 100 SSU
“B1*” - Return Line HT. EX. (D5 Power Units Only) = .34 Bar (5 PSI)
“B1” - Return Line HT. EX. with 56C-184TC Motors = .69 Bar (10 PSI)
“B2” - Return Line HT. EX. with 213TC-256TC Motors
= 1.38 Bar (20 PSI)
Heat removal is based on 4.4oC (40oF) differential between transfer medium.

Horsepower Removed
By Reservoir RESERVOIR SIZE LITERS (GALLONS) Heat removal is based on
18.9(5) 37.9(10) 75.7(20) 113.6(30) 151.4(40) static ambient air at 29.4oC
(85oF) and max. oil temperature
KW (HP) REMOVAL .15(.2) .28(.38) .43(.58) .51(.68) .60(.81)
of 57.2oC (135oF).

27 Parker Hannifin Corporation


ParkerHannifin
Parker
Hydraulic Pump Division HannifinCorporation
Corporation
HydraulicPump
Maryville, Ohio USAHydraulic Pumpand
Division
30
24 Marysville,
Power SystemsOhioDivision
USA
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Notes Series D, H, V-Packs

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 31
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
 
Introduction H-Pak with DCP
Introduction  
Introduction
Parker’s  DCP  PAK  (Drive  Controlled  PAK)  is  our  H  Pak  power  unit  with  SSD’s  AC10  inverter.    The  AC10  is  mounted,  wired,  
configured  and  factory  tested.    Simply  connect  power  per  local  safety  regulations,  fill  the  unit  with  oil  and  you’re  ready  to  run.    
Parker’s DCP Pak (Drive Controlled Pak) is our H Pak power unit with SSD’s AC10 inverter. The AC10 is mounted, wired,
The  AC10  has  a  lockable  disconnect  mounted  on  the  front  of  the  unit  and  has  an  IP66  rating.      
configured and factory tested. Simply connect power per local safety regulations, fill the unit with oil and you’re ready to run.
The
  AC10 has a lockable disconnect mounted on the front of the unit and has an IP66 rating.

Reliability  &  Energy  Savings  


Reliability & Energy Savings
1. Parker’s
Parker’s   DCP  DCP
PAK  sPak aves  saves
energy  energy and  improves  and improves reliability   reliability
compared   compared to units
to  units  that   that use
use  normal   normal
motor   motor
starters.       starters.
2. If rush 1. current is eliminated,
In  rush   the unit reduces
current  is  eliminated,   reducing   power
power  consumption
consumption  and and  w wear
ear  oon themmotor
n  the   andcouplings.  
otor  and   couplings.  
3. The unit’s 2. operation The  unit  can   can be  be
set  set
to  rtoun  match the
only  as   system
much   as  is  ndemand,
eeded  to  resulting
match  the  insystem  
less power demand,   consumption.
less  power  consumption.  
4. Less heat 3. generation Less  heat  generation,   improves icomponent mproving  component   and oil life. and  oil  life.  
5. Most applications
4. Quieter  run operation   at least partmtime
since   ost  abelow
pplications   1800wRPM, ill  run  aresulting in tquieter
t  least  part   operation.
ime  below   1800RPM.  
6. Less running5. Less   time at max
running   RPM
time   at  mimproves component
ax  RPM  improves   component  life, especially for the
life,  especially   pump
the   pump  and and  motor.
motor.  
7. A constant 6. Constant  95% power 95%  factor
power   results
factor.  in more
 This   efficient
results   in  more  useefficient  
of the electric motor,
use  of  the   especially
electric   motor,  eon largeromotors
specially   n  larger  that are only
motors  
partially loaded that  aand re  only  aren’t controlled
partially   loaded   by anainverter.
and   ren’t  controlled  by  an  inverter.  
8. The unit 7. has Ability   to  start  
the ability toand  
start stop  and the   motor  
stop theamotor s  often  asas  often
necessary   without  damaging  
as necessary without tdamaging he  motor.    Ltheess  motor.
wear  and   tear  
This on  the  
results in less
pump/motor   c oupling   a nd   r educed  
wear and tear on the pump/motor coupling and reduced power consumption due to reduced in-rush current. p ower   c onsumption   d ue   t o   r educed   i n-­‐rush   c urrent.    
 
Dual Rated CE Motors: While using a dual rated motor is not necessary when using an inverter, customers often request
Dual  Rwith
motors ated  aCE  
“CE” Motors:        While  uIf
certification. sing   you a  drequire
ual  rated  
a motor motor  iwith s  not  the
necessary  
“CE” mark, when  select using  athe
n  inverter,  
“D” prefix customers  
in the motor often  rhorsepower
equest   section
motors   w ith   a   “ CE”   c ertification.     I f   y ou  
of the H Pak model code. For example, “DL” will select a dual rated CE marked 5Hp (L) motor. r equire   a   m otor   w ith   t he   “ CE”   m ark,   s elect   t he   “ D”   p refix   in   t he   m otor   h orsepower  
section  of  the  H  PAK  model  code.    For  example,  “DL”  will  select  a  dual  rated  CE  marked  5Hp  (L)  motor.  

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 32
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Introduction H-Pak with DCP

Sample Power Comparison When Used on a Transfer, Clamp and Transfer Application.
Sample power comparison when used on a transfer, clamp and transfer application. 

The blue line represents the power consumed using a single speed pump. 
The blue line represents the power consumed using a single speed pump.
The orange line shows the power consumption using a Parker DCP in 2 speed mode. 
The orange line  shows the power consumption using a Parker DCP in 2 speed mode.

Cumulative Power Usage:


Cumulative Power Usage: 

1.8
1.6
1.4
1.2
1
KWH

0.8
0.6
0.4
0.2
0
2‐spd KWHrs 1‐spd KWHrs Accum KWHrs
 
   

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division
Marysville, Ohio USA
Available  Configurations:  

PARKER’S  DCP  PAK  is  available  in  5  factory  set  options.    The  software  and  settings  that  are  required  for  the  selected  option  will  
be  downloaded  and  tested  before  the  unit  is  shipped.    The  5  options  are  described  in  the  following  section.    Once  the  unit  is  
HY28-2661-CD/US Hydraulic Power Units
received  it  can  be  installed  and  used  without  any  programming  from  the  customer.    If  desired,  some  variables  can  be  adjusted  
Safety &via  
Technical Information
the  unit’s  keypad,   or  additional  edits  can  be  performed  by  using  a  laptop  computer.  H-Pak withinformation  
 For  detailed   DCP regarding  the  
drive  please  refer  to  the  drive’s  product  manual  HA502703U001,  available  at  parker.com  or  contact  Parker’s  SSD  Division.  

Available   Configurations:

PARKER’SIt   DCP Pakcustomer’s  


is  the   is available in 5 factory set options.
responsibility   The tsoftware
to  install   and settings
his  equipment   that
to  m areall  
eet   required for the
required   selected
safety   option  
standards.  
will be downloaded and tested before the unit is shipped. The 5 options are described in the following section. Once the unit is
received, itProper   electrical  
can be installed andisolation  
used withoutfor  any
maintenance  
programmingand   fromarc  
theflash  
customer.control   must  some
If desired, be  provided.  
variables can be adjusted
via the unit’s keypad, or additional edits can be performed by using a laptop computer. For detailed information regarding the
  refer to the drive’s product manual HA502703U001, available at www.parker.com or contact Parker’s
drive, please
SSD Division.
 
It is the customer’s responsibility to install this equipment to meet all required safety standards. Proper electrical isolation for
 
maintenance and arc flash control must be provided.
 

WARNING: Branch circuit protection with a maximum rating of 5KA current limiting must be supplied
WARNING - USER codes.
per local electrical RESPONSIBILITY
R SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
D PROPERTY DAMAGE.
ormation from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
pertise.

alysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
ning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
he product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
ts subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
hat such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
ns stated in the detailed "Offer of Sale" elsewhere in this document.

Parker Hannifin Corporation


Hydraulic Pump and
34 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Safety & Technical Information H-Pak with DCP

While ensuring ventilation is sufficient,


provide guarding and/or additional safety
systems to provide injusry or damage to
equipment.

! !

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Safety & Technical Information H-Pak with DCP

Control Options Control  Options  

Analog Speed
Analog   speed   Control:
control:    YYou ou  ccan
an  pprovide
rovide  either  
either a  4a-­‐20mA  
4-20mA (option  
(option I)  or  
I)0or -­‐10VDC  
0-10VDC (option   V)  command  
(option V) command signal  tsignal
o  control  to Rcontrol
PM.    The  
RPM.
The unit will
unit   bebe  
will   pre-configured
pre-­‐configured  based based  oon n  yyour
our  mmodel code
odel  code   selection
selection   and  and is scaled
is  scaled   to operate
to  operate   between
between   500at  RPM
500  RPM   minimum  at minimum
signal  
signal and  
and22000 000  RPM   RPM at  at maximum
maximum   signal.
signal.    One  One digital
digital   signal
signal   (contact
(contact   closure   closure or 24VDC
or  24VDC   source)  isource)
s  required   is trequired
o  enable  tto he  enable the
drive  and  
drive and
another   another is required
is  required   to astart
to  start   andthe  
nd  stop   stop the  Tdrive.
drive.   The
he  min   min
and   max   and maxcan  
values   values can be(ref  
be  changed   changed
to  the  A(ref
C10  to the AC10
operating   operating
manual)   but  
manual) but
it  is   not  itris not recommended
ecommended   that  the  that
minimum   the minimum
setting  be  setting
set  any  be set aany
lower   nd  tlower and
hat  the   that thesetting  
maximum   maximum setting
not  be   not
set  any   be set
higher.   any
 Pump  
higher.efficiency  
Pump efficiency drops dramatically
drops  dramatically   below  500RPM   below 500RPM
and   pump  and  and or  pump
motor  and or motor
damage   may  rdamage
esult  with  may
speeds  result with
above   speeds
2200RPM.  
above 2200RPM.
CAUTION:    Disabling  the  drive  DOES  NOT  remove  power  from  the  motor.    High  voltage  can  be  present  at  the  motor  leads  even  
CAUTION:
when  the   Disablingmotor  is  the not  drive DOES
running.    To  eNOT
nsure  remove
the  motor  power from
is  safe   to  wthe
ire,  motor.
make  sHigh voltage
ure  the   can be
disconnect   present
is  locked   in  tat
he  the
OFF  motor leads
position,  
even when
incoming   the pmotor ower  iis
s  rnot running.
emoved   and  tTo he  ensure
AC10’s  dthe motor
isplay   and  is safeare  
LED’s   to owire, make sure
ff,  indicating   the  cthe disconnect
apacitors   is locked    in the OFF
are  discharged.  
position, incoming power is removed and the AC10’s display and LED’s are off, indicating the capacitors are discharged.
 

*
   
 

 

 *  The  setting
* The default switch default  when
switch  ordering
setting  wvoltage control
hen  ordering   (option
voltage   V) will
control   be 0-10VDC.
(option   V)  will  be  If 0-5VDC  If  is0-­‐5VDC  
0-­‐10VDC.   required the customer
is  required   the    
must change
  the            switch settings
         customer   forchange  
must   0-5VDC. the  switch  settings  for  0-­‐5VDC.  

If  Dinstall
If DI2 is not used, I2  is  not   used  install  
a jumper between a  jumper  
DI1band etween  
DI2.DI1  and  DI2.    

Parker Hannifin Corporation


Hydraulic Pump and
36 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Safety & Technical Information H-Pak with DCP
 

Discrete
Discrete  Speed
speed  cControl:
ontrol:    If  oIfption  
option “D”
“D”   is  sis selected
elected   the  uthe
nit  unit
will  bwill be configured
e  configured   to operate
to  operate   at 8 different
at  8  different   speeds  speeds based  on   based
the   on the
combination of making
combination   3 inputs
of  making   3  inputs   active. There
active.    There  are
are  also
also  two
two  discrete
discrete  iinputs
nputs  tthat hat  nneed tobe  
eed  to   bewired  
wiredby  by the
the   customer
customer   to  eto enable
nable   the   the
drive.drive.  
DI1  and
DI1  aDI2
nd  Dneed to be
I2  need   to  b“ON” (held
e  “ON”   (held   ata24VDC)
t  24VDC)  to to  start
start  tthe
he  ddrive.
rive.    IIff  eeither inputggoes
ither  input   low
oes  low   the
the   unit
unit   will
will   stop.
stop.   See
 See   the  the wiring
wiring  
example
example  below.    The  unit  will  be  factory  set  to  operate  at  the  speeds  shown  in  the  diagram.    These  speeds  can  be  changed  by   by
below. The unit will be factory set to operate at the speeds shown in the diagram. These speeds can be changed
the customer using
the  customer   thethe  
using   keypad
keypad   orocomputer
r  computer   interface
interface  (ref
(ref  to
to  the
the  AC10
AC10  ooperating
perating  mmanual). anual).  

CAUTION: Disabling
CAUTION:    Disabling  the
the  drive
drive  DOES
DOES  NNOT remove
OT  remove   power
power   from
from   the  the motor.
motor.   High
 High   voltage
voltage   can  bcan be present
e  present   at  the  at the motor
motor   leads  eleads
ven  
evenwhen  
whenthe  
themmotor
otor  is  is not
not   running.
running.    To  To ensure
ensure   the  the motor
motor   is safe
is  safe   to wire,
to  wire,   make  make sure
sure  the   the disconnect
disconnect   isin  
is  locked   locked inpthe
the  OFF   OFF
osition,  
position, incoming power is removed and the AC10’s display and LED’s are off, indicating the capacitors
incoming  power  is  removed  and  the  AC10’s  display  and  LED’s  are  off,  indicating  the  capacitors  are  discharged.       are discharged.

 
If DI2   is not used, install a jumper between DI1 and DI2.

If  DI2  is  not  used  install  a  jumper  between  DI1  and  DI2.    

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 37
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Safety & Technical Information H-Pak with DCP
Auto  2  Speed  based  on  motor  current:    This  configuration  (option  “Q”)  will  run  at  full  rated  speed  (1800RPM)  and  then  
Autoautomatically  
2 Speed Based drop  to  on Motorspeed  
minimum   Current: Thiswconfiguration
(600RPM)   hen  the  motor  (option
current  “Q”) will arun
exceeds   at fullvalue.  
 certain   rated  Tspeed (1800RPM)
his  speed   change  is  nand
ot   then
automatically
internally  drop to minimum
triggered,   speed (600RPM)
it  is  accomplished   using  an  o when
utput  the motor
wired   to  an   current
input.    exceeds
The  unit  waill  certain
have  a  value.
jumper  This wire  speed
that  connects   changerelay   is not
internally triggered.
output   TA  to  DI3.  It  isWaccomplished usinglevel  
hen  the  max  current   an output wiredTto
is  exceeded   A  tan
urns   input.on,  bThe unit
ringing   DI3  will have
high.   a jumper
 When   DI3  is  wire
high  tthat he  uconnects
nit  runs  at  relay
outputminimum  
TA to DI3. When
speed.   theconfiguration  
   This   max currentwlevel orks  w isell  
exceeded
in  clamping   TActurns
ircuits  on, bringing
where   initial  DI3 high.mWhen
cylinder   ovement   DI3 is  is high
rapid   thelow  
with   unit runs at
minimum speed. This configuration works well in clamping circuits where initial cylinder movement is rapid with low resistance
resistance  followed  by  stalling  at  clamping  pressure  and  very  little  flow.    If  the  jumper  between  TA  and  DI3  is  removed  or  
followed by stalling at clamping pressure and very little flow. If the jumper between TA and DI3 is removed or controlled
controlled  externally  additional  possibilities  can  be  realized  based  on  how  the  customer  manipulates  DI3.    For  example,  a  
externally additional possibilities can be realized based on how the customer manipulates DI3. For example, a pressure switch
or PLC pressure  
could be switch  
used or  alone
PLC  could   be  uDI3
or with sed  atolone  
reduce or  with  
speed.DI3  to   reduce  
There are speed.  
also  Ttwo
here   are  also  inputs
discrete two  discrete  
that need inputs  
to tbe hat  wired
need  tby
o  bthe
e  
wired   b y   t he   c ustomer   t o   e nable   t he   d rive.     D I1   a nd   D
customer to enable the drive. DI1 and DI2 need to be “ON” (held at 24VDC) to start the drive. If either input goes low the I2   n eed   t o   b e   “ ON”   ( held   a t   2 4VDC)   t o   s tart   t he   d rive.     I f   e ither   input   goes  
unit
low  the  unit  will  stop.      
will stop.
Factory  
Factory settings settings   for option for  option   Q: When Q:    When   motor motor   current  
current > 95% >  95%  
FLA, FLA,  DO1
DO1  tturns
urns  oon.
n.    SSee
ee  F310  
F310 in  in
AC10  
AC10 manual.  
manual.
                                                                                                             When  motor  current  <  75%  FLA,  DO1  turns  off.  See  F311  in  AC10  manual.  
WhenF310   motor is  acurrent n  absolute   < 75% number,   FLA,ie  DO1 19  amps.  
turns off. See F311 in AC10 manual.
F310 is an absolute number, ie 19 O1  
F311   i s   a   p ercentage,   i e   1 5%.     D amps. turns  on  when  the  motor  current  exceeds  19  amps  and  turns  off  when  the  motor    
F311 current  
is a percentage, is  less  than  ie(19-­‐19x15%)   15%. DO1oturns r  16.15  
onamps.  
when the motor current exceeds 19 amps and turns off when the motor
  is less than (19-19x15%) or 16.15 amps.
current
These  values  can  be  changed  by  the  customer  using  the  keypad  or  computer  interface  (ref  to  the  AC10  operating  manual).  
These values can be changed by the customer using the keypad or computer interface (ref to the AC10 operating manual).
NOTE:  If  your  application  requires  a  lot  of  force  during  pre-­‐travel  or  consumes  flow  during  clamping,  the  system  may  hunt  as  
the  motor  current  crosses  the  MIN  and  MAX  current  levels.    Option  D  (speed  determined  by  inputs,  not  current)  may  be  a  
NOTE: If your application requires a lot of force during pre-travel or consumes flow during clamping, the system may hunt
as the motoroption  
better   current in  tcrosses
hese  cases.  
the MIN and MAX current levels. Option D (speed determined by inputs, not current) may be a
better option in these cases.
CAUTION:    Disabling  the  drive  DOES  NOT  remove  power  from  the  motor.    High  voltage  can  be  present  at  the  motor  leads  even  
when  the  motor  is  not  running.    To  ensure  the  motor  is  safe  to  wire,  make  sure  the  disconnect  is  locked  in  the  OFF  position,  
CAUTION: Disabling the drive DOES NOT remove power from the motor. High voltage can be present at the motor leads
even incoming  
when thepmotor ower  is  isremoved   and  the  
not running. ToAensure
C10’s  display  
the motor and  LisED’s  
safe are  tooff,  
wire, indicating  
make sure the  capacitors  
the disconnectare  discharged.  
is locked     in the OFF
position, incoming power is removed and the AC10’s display and LED’s are off, indicating the capacitors are discharged.
 

 
                                                                                                   
 

If DI2If  isDI2  
not is  n ot  used  
used installinstall  
a ajumper
 jumper  between
between  D I1  aand
DI1 nd  DDI2.
I2.  

Parker Hannifin Corporation


Hydraulic Pump and
38 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Soft  Start:    Option  “S”  is  simply  a  soft  start  application.    When  enabled  the  motor  will  accelerate  H-Pak
to  max  RPM  
with (factory  
DCPset  at  
Safety & Technical Information
1800RPM)  over  2  secs.      This  option  can  help  protect  the  couplings  and  pump  from  wear  and  like  all  the  above  options,  inrush  
current  is  controlled  to  minimize  motor  winding  stresses.    It  also  gives  the  pump  a  better  chance  to  properly  prime  before  full  
Soft flow  
Start: is  achieved.  
Option “S” is simply a soft start application. When enabled the motor will accelerate to max RPM (factory set at
1800RPM) over 2 secs. This option can help protect the couplings and pump from wear and like all the above options, inrush
CAUTION:    Disabling  the  drive  DOES  NOT  remove  power  from  the  motor.    High  voltage  can  be  present  at  the  motor  leads  even  
current is controlled to minimize motor winding stresses. It also gives the pump a better chance to properly prime before full
the  motor  is  not  running.    To  ensure  the  motor  is  safe  to  wire,  make  sure  the  disconnect  is  locked  in  the  OFF  position,  
flow iswhen  
achieved.
incoming  power  is  removed  and  the  AC10’s  display  and  LED’s  are  off,  indicating  the  capacitors  are  discharged.      
CAUTION:
  Disabling the drive DOES NOT remove power from the motor. High voltage can be present at the motor leads
even when the motor is not running. To ensure the motor is safe to wire, make sure the disconnect is locked in the OFF
position,
  incoming power is removed and the AC10’s display and LED’s are off, indicating the capacitors are discharged.

  OPTIONAL BY CUSTOMER

If  DI2  is  not  used  install  a  jumper  between  DI1  and  DI2.  

If DI2   is not used, install a jumper between DI1 and DI2.

   

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 39
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Safety & Technical Information H-Pak with DCP

AC10 Part Numbers:


HP Voltage Hp/Voltage AC 10 Part Numbers
2 Incoming Power 230VAC 3 Phase 16G-31-0070-BF-DT
2
4 Incoming Power 460VAC 3 Phase 16G-41-0040-BF-DT
2 Incoming Power 230VAC 3 Phase 16G-31-0100-BF-DT
3
4 Incoming Power 460VAC 3 Phase 16G-41-0065-BF-DT
5 4 Incoming Power 460VAC 3 Phase 16G-41-0090-BF-DT
7.5 4 Incoming Power 460VAC 3 Phase 16G-42-0120-BF-DT
10 4 Incoming Power 460VAC 3 Phase 16G-42-0170-BF-DT
15 4 Incoming Power 460VAC 3 Phase 16G-43-0230-BF-DT
20 4 Incoming Power 460VAC 3 Phase 16G-43-0320-BF-DT

AC10 Power Ratings:


Input Output Input Inductance
Esitmated
Supply Part Number kW Current Current Protection of Output
Efficiency
(A) (A) Current Choke (mH)
16G-31-0025-BF 0.4 4.3 2.5 8.2 95
16G-31-0045-BF 0.75 7.6 4.5 11.5 95
3Ph 230V
16G-31-0070-BF 1.5 12.0 7 18.2 96
16G-31-0100-BF 2.2 14.3 10 21.5 96
16G-41-0020-BF 0.75 4.1 2 6.5 95
16G-41-0040-BF 1.5 6.9 4 11.0 96
16G-41-0065-BF 2.2 9.6 6.5 15.0 96
16G-41-0080-BF 3.7 11.6 8 18.0 96
3Ph 400V 16G-41-0090-BF 4.0 13.6 9 21.0 96
16G-42-0120-BF 5.5 18.8 12 29.0 96
16G-42-0170-BF 7.5 22.1 17 34.0 96
16G-43-0230-BF 11 30.9 23 46.5 97
16G-43-0320-BF 15 52 32 80.0 97

Parker Hannifin Corporation


Hydraulic Pump and
40 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Notes H-Pak with DCP

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 41
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Catalog HY13-1552-002/US,EU Low Profile Power Units
Introduction VolumeV-Paks
Series Control V-Pak Low Profile Series
Introduction

SINGLEREMOV-
SINGLE REMOVABLE
TOP TOPPLATE
ABLE PLATE
PRESSURE PORT
RETURN PORT
FILLER/BREATHER

PUMP COMPENSATOR
CONTROL

OIL LEVEL GUAGE


WITH THERMOM- PUMP CASE PREFILL PORT
ETER
406mm (16") GLYCERINE FILLED
CLEANOUT COVER PRESSURE GUAGE WITH
SHUT-OFF VALVE
SAFETY RELIEF VALVE
SAE-12 RESERVOIR
DRAIN

Standard Features Benefits

• Vertical Design • Saves Floor Space


• Submerged Pump • Positive Pump Inlet
• Precision Pump Mounting Adapters • Longer Pump Life
• Suction Strainer • Protects Pump from Contamination
• Glycerine Filled Pressure Gage with Shut Off • Improved Diagnostics
• Oil Level Gage with Thermometer • Helps to Maintain Trouble-Free Performance
• Remote Compensator and Safety Relief • Protects Against System Shock
• Breather and Fill Cap • Easy to Fill Tank, Control Ingression of Airborne
Contaminants
• 1800 RPM Motor
• More Flow at Less Cost
• Drain Plug
• Allows Drainage of Fluid
• Clean Out Cover
• Easy Access to Inside of Reservoir
• Single Removable Topplate
• Easy Servicability of Internal Components
• Extra SAE-20 Return Port
• Allows Flexibility for Customer Return Plumbing
• All Hydraulic Connections SAE Straight Thread
• No Leaks

Quick Reference Data Chart


Low Profile Tank Size Pump Flow Electrical Motors Maximum
V-Pak Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)
V8 302.8 (80) 136.7 (36.1) 5.6 - 30 (7 1/2 - 40) 207 (3000)

2 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin Corporation
Marysville, Ohio USA
Hydraulic Pump and
42 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US
HY28-2661-CD/US HydraulicPower
Hydraulic PowerUnits
Units
Catalog HY13-1552-002/US,EU Low Profile Power Units
Introduction
Introduction VolumeV-Paks
Series Control V-PakLow
V-Pak LowProfile
Profile Series
Series
Introduction

Performance Data
Standard Features
• Vertical Design
• Submerged Pump
• Precision Pump Mounting Adapters
• Suction Strainer
• Glycerine Filled Pressure Gage with Shut Off
• Oil Level Gage with Thermometer
• Relief Valve
• External Pump Compensator Control
• Breather and Fill Cap
• 1800 RPM TEFC Motor
• Cleanout Cover
• Pressure and Return Port Block with Safety Relief
• Remote Pump Compensator Control Valve

Options
• D05 (D02) Single Station Manifold Warranty
with Safety Relief The hydraulic components on these Parker Power
• D05 (D02), D08 (D06) Multi-Station Manifold Units are warranteed for one year. This warranty may
with Safety Relief be extended to three years by using and properly
• Pressure & Return Filters (10 Micron) maintaining Parker filters.
• Variety of Manapak Sandwich Valves SUPPLY RETURN
• Heat Exchangers (Air/Oil) Schematic Symbol PORT PORT
SAE-16 SAE-20
• Combination Temp/Float Switch - Temp Fixed (Basic Unit) P T
• Single Pressure Remote Compensator “O”
OPTION
• Single Pressure Remote Compensator with Low MANIFOLD

Pressure Standby
• Bi-Pressure Remote Compensator
• Bi-Pressure Remote Compensator with Low
Pressure Standby
• Load Sensing (Flow Control)-Consult Factory M SAE-20
SPARE
• Horsepower Limiting-Consult Factory RETURN
“OMIT”
• Rated 50/60Hz Motors OPTION
COMP
CONTROL
Specifications SAE X
-12
Parker “V-Pak” Hydraulic Power Units are vertical V-PAK BASIC UNIT
design, 303 liter (80 gallon) reservoirs utilizing Parker —————————
NO OPTIONS OR ACCESSORIES
Variable Volume Piston Pumps.
“OMIT” OPTION PUMP COMPENSATOR
“O” OPTION MANIFOLD
Installation Data:
See page 19 of this catalog or Parker Installation/
Maintenance Manual for specific recommendations
pertaining to start-up, system cleanliness, fluids,
temperatures and other important factors relative to
proper installation and use of these power units.

Pump Tank Size Pump Flow Electrical Motors Maximum


Model Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)

V8 302.8 (80) 136.7 (11.0-36.1) 5.6 - 30 (7 1/2 - 40) 207 (3000)

3 Parker Hannifin Corporation


Parker Hannifin
Parker HannifinCorporation
Corporation Hydraulic Pump Division
Marysville, Ohio USA
Hydraulic Pump
Hydraulic PumpDivision
and
Marysville,
Power Ohio USA
Systems Division 43
27
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
V-Pak Low Profile Ordering Information V-Pak Low Profile Series

V8 OR Reduced
Flow

Reservoir Size Pressure Pump Control Pump Flow D = Dual Rated• Electric Manifold
80 Gallons Control W = No Motor•• Motor
(302.8 Liters)

Code Pressure Control If No Motor or Electric Motor Description


Code
Omit Single Pressure Remote Compensator Dual Rated HP (KW) - RPM Frame Phase
W M 213TC (no motor)
Single Pressure Remote Compensator
B M 7.5 (5.6) - 1725 - 213TC - 3
with Low Pressure Standby
D M 7.5 (5.6) - 1725 - 213TC - 3 DUAL RATED
Single Pressure Remote Compensator W N 215TC (no motor)
BJ
with Low Pressure Standby, 24 VDC
N 10 (7.5) - 1725 - 215TC - 3
C Bi-Pressure Remote Compensator D N 10 (7.5) - 1725 - 215TC - 3 DUAL RATED
CJ Bi-Pressure Remote Compensator, 24VDC W P 254TC (no motor)
P 15 (11.2) - 1725 - 254TC - 3
Bi-Pressure Remote Compensator with Low Pressure
D D P 15 (11.2) - 1725 - 254TC - 3 DUAL RATED
Standby
W S 256TC (no motor)
Bi-Pressure Remote Compensator
DJ S 20 (14.9) - 1725 - 256TC - 3
with Low Pressure Standby, 24VDC
D S 20 (14.9) - 1725 - 256TC - 3 DUAL RATED
F Provision for Customer Supplied Remote Control Relief Valve W Q 284TC (no motor)
Q 25 (18.6) - 1725 - 284TC - 3
Code Pump Control D Q 25 (18.6) - 1725 - 284TC - 3 DUAL RATED
W R 286TC (no motor)
Omit Std. Remote Compensator
R 30 (22.4) - 1725 - 286TC - 3
Load Sense D R 30 (22.4) - 1725 - 286TC - 3 DUAL RATED
A*
Flow Control W V 324TC (no motor)
*Unless otherwise specified, a SAE-6 37° flared port will be supplied for V 40 (29.8) - 1725 - 324TC -3
customer connection. D V 40 (29.8) - 1725 - 324TC -3
**Consult factory for horsepower and hi-lo pump control options. Three phase electric motors are rated as follows:
Lead time is four weeks. 208-230/460V, 3PH, TEFC - 60 Hertz 1800 RPM 1.15 SF
• Dual rated motors include the 60Hz ratings plus 190/380V 50Hz (1.0SF)
Pump Flow Rate 1450RPM 10:1CT/20:1VT INVERTER RATED UR/CSA/CSA EEV/CE
Code Pump Used and Description • Dual rated motors may have longer than standard leadtime. Options G & K3
@1800 RPM
are dual rated as standard.
15 15.6 GPM (59 LPM) PVP33 - Std. Remote Compensator
Consult factory for other motor speeds (RPM) and voltages.
23 23.0 GPM (87 LPM) PVP48 - Std. Remote Compensator
•• Use W prefix when no motor is required on unit.
36 36.1 GPM (137 LPM) P2075 - Std. Remote Compensator When ordering, W must be followed by motor model code equivalent to
* Specify in GPM Destroked (Reduced) Flow frame size of motor to be used.
DO NOT USE “W” and “D” together I.E: 213TC unit with no motor is called out “WM”.
*Unless otherwise specified, units are shipped at max. flow rate (GPM) at
1800 RPM.
When reduced flow setting is required, Reduced flows from 22.5 to 8.0 Supply/Return
GPM (85.2 to 30.3 LPM), specify in 0.5 GPM increments. Porting Block/Subplate
Code Port or Other
Reduced flows from 35.0 to 24.0 GPM (132.5 to 90.8 LPM), or Manifold Type
Actuator Port Size
specify in 1.0 GPM (3.8 LPM) increments.
Example: V*9.5**-- = PVP33 Pump destroked to 9.5 GPM (36.0 LPM) Pressure and Return Port Block P Port SAE-16
Omit None
V*A31**-- = P2075 Load Sense Pump destroked to 31.0 GPM with Safety Relief Valve T Port SAE-20
(177.3 LPM)
•Use D prefix to specify dual rated motor. When ordering, D must be D05 Single Station Subplate A & B Ports
S5 None
with Safety Relief Valve SAE-10 Str. Thr'd
followed by the motor model code.
D05 Multistation Parallel Circuit
A & B Ports
M5* (2) Manifold with Safety Relief and None
SAE-8 Str. Thr'd
Pump Compensator Valves
NOTE: Y Port
D08 Two Parallel Circuit Manifold
1. Manifolds are mounted vertically. A & B Ports SAE-8
M82 (3) with Safety Relief and
Bottom station is number 1. SAE-16 Str. Thr'd Str.
Pump Compensator Valves
2. M5-3 and 5 station available. Thr'd
M8-2 station available.
*When ordering Multi-Station Manifolds, the number of stations must
be specified. If valves are to be mounted, specify the valves and
sequence, if the model code exceeds 25 digits, call factory.
Example: V815QM53BCB1 Example: V815QM55B1B1CBC
3 Station D05 Manifold 5-Station D05 Manifold
Station #1: B Station #1: B1
= Omit if not required Station #2: C Station #2: B1
Station #3: B1 Station #3: C
Station #4: B
Station #5: C
Parker Hannifin Corporation
Hydraulic Pump and
44 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
V-Pak Low Profile Ordering Information V-Pak Low Profile Series

P
Directional Manapak Options
Control Control and
Valve Valves• Accessories

Directional
NFPA Nominal
Control Valve
Code Mounting Flow GPM Description Circuit Symbol
Valve Model
Pad (LPM)
Number
Double
AB

B D3W1CNYCCF D05 20
(Spr. Ctr) PT

Double AB

C D3W4CNYCCF D05 15
(Spr. Ctr) PT

Manapak
NFPA
Control Valve Model Nominal Flow
Code Mounting Circuit Symbol
Valves Number GPM (LPM)
Pad
Function

1 FM3DDKN D05 D05 7 (26.5)

3 CPOM3DDN D05 D05 7 (26.5)

*Manapak valves mounted in order of callout.


First valve will be nearest DCV; last valve will be on manifold.

Options and Accessories


Code
Function Model Number Technical Data
Continuous Pump Air/Oil: .8Hp (.6KW) Rej Available on 7.5Hp thru 25Hp (5.6
A* RM-08-2-2
Case Cooling -18.5KW) motors
Continuous Pump
B* RM-19-2-2 Air/Oil: 1.5Hp (1.1KW) Rej
Case Cooling
Air/Oil w/1PH Motor: Oil flow 8GPM (30LPM) 4.5Hp
AOC-22-2-1PH
C#^ Filter Cooling Loop (3.3KW) heat rejection Includes 3/4" weld coupling for
40CN205Q
customer supplied device (Temp switch for fan)
Water/oil: 17Hp (12.7 KW)Rej @ 20GPM Oil Flow 2:1 Flow
Return Line Heat
E#^ EKS-708-T ratio Max oil Flow 60GPM Max water flow 12 GPM Includes
Exchanger
3/4" weld coupling for customer supplied device
Water valve/ 65253 + bulbwell + If ordered without option E this option will only include the
F^
bulbwell 3/4" weld coupling 3/4" weld coupling.
10 Micron Microglass II Dual Element,
H Pressure Filter 30P210QM250NN1
Mechanical Indicator
J 2" Weld coupling for customer supplied heater
Check Valve
K 493-16-D1-2 5 PSI (0.3 bar) Cracking Pressure
Pump Outlet
L Bypass Check C2020S65 65 PSI (4.6 bar) Cracking Pressure
10 Micron Microglass II Dual Element,
N Return Filter 40CN210Q
Mechanical Indicator** (8 PSID)
Combination
Fixed Temp at 65°C (149°F)
R1 Float/Temp. Switch 877501
Close @ Low Level and/or 65°C (149°F) (N.O.)
N.O. Float Up
Combination
Fixed Temp at 65°C (149°F)
R2 Float/Temp. Switch 877502
Open @ Low Level and/or 65°C (149°F) (N.C.)
N.C. Float Up

*Heat rejection based on 72 deg F differential between the oil and the ambient temperature.
#Heat rejection based on 40deg F differential between tranfer medium.
^ May require longer than standard lead time.
DO NOT select more than one offline loop, A or B or C. C & E cannot be selected together.

= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 45
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Installation
Installation Information
Information
Catalog HY13-1552-002/US,EU Low Profile Power Units V-Pak Low Profile Series
Technical Information VolumeV-Paks
Series Control

Dimensions – Basic V-Pak Low Profile


Shown with “Omit” Option Manifold
Inch equivalents for millimeters dimensions are shown in (**). Installation information is for reference only, consult
factory or visit Parker's Econfigurator for detailed information.
Motor Motor Description Dimension
Code KW(HP)-RPM-Frame-Typ e "A" "B"

M 7.5 (5.6) - 1725 - 213TC - 3 458(18) N/A


273.1
"B"
(10.75)
473
N 10 (7.5) - 1725 - 215TC - 3 N/A
(18.6)

522 48
231.7
P 15 (11.2) - 1725 - 254TC - 3
(20.5) (1.88)
FILTER (9.12)
BREATHER
(STANDARD) 522 48
S 20 (14.9) - 1725 - 256TC - 3
(20.5) (1.88)

611 51
819.2 Q 25 (18.6) - 1725 - 284TC - 3
(32.25) (24) (2.0)
PUMP COMPENSATOR
CONTROL

SAE-20
51
PUMP PRIME

SPARE RETURN
R 30 (22.4) - 1725 - 286TC - 3 611
PORT (24) (2.0)
T
789 144
P
V 40 (29.8) - 1725 - 324TC -3
SAFETY RELIEF
DO NOT ADJUST

(31) (5.69)

SUPPLY PORT
72.9 736.6 SAE-16 ORB
(2.87) (29.0)
838.2
(33.0) RETURN PORT
914.4 SAE-20 ORB
(36.0)
"O" OPTION
SAE-20 SPARE RETURN MANIFOLD
PORT (AVAILABLE WITHOUT
* Reference dimension consult factory
RETURN FILTER ONLY)
if critical to application.
SAFETY RELIEF VALVE
MAINTAIN 31 BAR (450 PSI) REMOTE PUMP
ABOVE PUMP COMPENSATOR COMPENSATOR
CONTROL SETTING CONTROL ADJUSTMENT

TOPPLATE PUMP CASE "A"*


LIFTING EYE FILL PORT
TYP.-3 PLCS.
PRESSURE GUAGE
WITH SHUT-OFF VALVE
CLEAN-OUT
COVER

V-PAK

FULL MARK

725
(28.56)
432
(17.0)
Ø15.9 (.625)
TYP. -4 PLCS.

63.5
SAE-12 952.5 (2.50) 68.6
TANK DRAIN (37.5) 720.3 (2.70)
990.6 (28.36)
(39.0)
769.5
(31.36)
878.6
(34.59)

6 Parker Hannifin Corporation


ParkerHannifin
Parker HannifinCorporation
Corporation
Hydraulic Pump Division
HydraulicPump
Hydraulic Pumpand
Division
Marysville, Ohio USA
46
30 Marysville, Ohio USA
Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Low Profile Power Units Hydraulic Power Units
Catalog HY13-1552-002/US,EU
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

V-Pak Low Profile S5 Manifold Options


Inch equivalents for millimeters dimensions are shown in (**)

S5
SUBPLATE OPTION
FOR USE WITH D3W VALVE
(NFPA D05)

T P

71.4
(2.81)

38.1
(1.50)
A-D03 B-D03
B-D05 A-D05

26.9
(1.06) 54.1
(2.13)
SUPPLY RETURN
PORT PORT
SAE-12 SAE-12
X

RETURN P T "A"
PORT X P A PORT
SAE-12 SAE-10
T B "B"
PORT
SAE-10
RETURN D05
X MNTG
PORT
SURFACE
SAE-12
PUMP
SUPPLY

7 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin Corporation Marysville, Ohio USA
Hydraulic Pump and
Power Systems Division 47
Marysville, Ohio USA
HY28-2661-CD/US Low Profile Power Units Hydraulic Power Units
Catalog HY13-1552-002/US,EU
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

V-Pak Low Profile M53/M55 & M82 Manifold Options


Inch equivalents for millimeters dimensions are shown in (**).

"M53/M55 Option" RETURN


PORT
SAE-12

X
P T
A

"A"&"B"PORTS

3 AND 5 STATIONS
B

SAE-8

T
A

P
G B
"G"
D05 1.25
SAE-6
MNTG
SURFACE

PUMP
SUPPLY
M53 AND M55
3 AND 5 STATION MANIFOLD OPTIONS

FOR USE WITH NFPA D05 VALVES 83.0


(3.25)
PER STATION

3 AND 5 B A
STATION
AVAIL.
165.0 G 83.0
(6.5) (3.25)
B A

40.0
17.5 (1.56)
(0.69) 54.0
(2.12)

"M82 Option"
RETURN
PORT
SAE-16
X

P
T

"Y"
SAE-8
Y
B
A

"A"&"B"PORTS

(2 STATIONS)
-16 SAE
B
A

"G"
-6 SAE
G

T P
P
T

46.0
(1.81)
M82
2 STATION MANIFOLD OPTION

FOR USE WITH NFPA D08 VALVES


SAE-8 "Y" PORT, NO "X" PORT

B A

266.7
(10.50) 133.4
G
(5.25)
B A

50.8
26.9 (2.00)
(1.06)
66.8
(2.63)

8 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin Corporation
Marysville, Ohio USA
Hydraulic Pump and
48 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Low Profile Power Units Hydraulic Power Units
Catalog HY13-1552-002/US,EU
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

V-Pak Low Profile – Compensator Options


Inch equivalents for millimeters dimensions are shown in (**)

"B" OPTION
"OMIT" OPTION T
HIGH LOW
SINGLE PRESSURE
SINGLE PRESSURE PSI PSI LOW SOL
REMOTE COMPENSATOR STANDBY
REMOTE COMPENSATOR
W/LOW PRESS STANDBY

P T HIGH
SOL
P
P

SAE SOLENOID IS LOW WATT


-6 WITH DIN.43650 CONNECTOR
AND MANUAL OVERRIDE
PUMP CASE AUX.VENT PORT (SAE-6)
PRE-FILL PORT PUMP CASE LOW PRESS.STANDBY(N.O.)
PUMP COMPENSATOR PRE-FILL PORT ENERGIZE TO BUILD PRESSURE
CONTROL ADJUSTMENT
PUMP COMPENSATOR
CONTROL ADJUSTMENT
HI LO
SOL SOL

HI
LO

"C" OPTION "D" OPTION


T T
BI-PRESSURE HIGH LOW HIGH LOW
PSI PSI
BI-PRESSURE PSI PSI LOW SOL
REMOTE COMPENSATOR REMOTE COMPENSATOR STANDBY
W/LOW PRESS STANDBY

HIGH HIGH
SOL SOL
P P

SOLENOID IS LOW WATT SOLENOIDS ARE LOW WATT


WITH DIN.43650 CONNECTOR WITH DIN.43650 CONNECTOR
AND MANUAL OVERRIDE AND MANUAL OVERRIDE
PUMP CASE PUMP CASE
PRE-FILL PORT HIGH PRESS.SOLENOID (N.O.) PRE-FILL PORT HIGH PRESS. SOLENOID (N.O.)
ENERGIZE FOR HIGH PRESSURE ENERGIZE FOR HIGH PRESSURE

PUMP COMPENSATOR LOW PRESS. STANDBY (N.O.)


HIGH PRESS.CONTROL ENERGIZE FOR LOW PRESSURE
HI LO HI LO
SOL SOL SOL SOL

HI HI

LO LO

PUMP COMPENSATOR
PUMP COMPENSATOR HIGH PRESS. CONTROL
LOW PRESS.CONTROL
PUMP COMPENSATOR
LOW PRESS. CONTROL

SAE-6
"E" OPTION 37˚ FLARE
P T
PROVISION FOR
CUSTOMER SUPPLIED
P
REMOTE COMPENSATOR

PUMP COMPENSATOR
T PRESSURE (INLET) PORT
PUMP COMPENSATOR
TANK (RETURN) PORT

PUMP CASE SAE-6 37˚ FLARE "P" & "T" PORTS


PRE-FILL PORT ATTACH POINTS FOR CUSTOMER
SUPPLIED REMOTE COMPENSATOR

9 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin Corporation Marysville, Ohio USA
Hydraulic Pump and
Power Systems Division 49
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information V-Pak Low Profile Series

Accessory Options
V-Pak LOW PROFILE

HEAT EXCHANGER
PRESSURE SWITCH
RETURN FILTER

BREATHER MULTI-STATION
MANIFOLD

PRESSURE FILTER
TEMP/LEVEL
SWITCH
SWITCH
TEMP. SWITCH

EXAMPLE OF VARIOUS
ACCESSORIES INSTALLED
FOR REFERENCE ONLY

SCHEMATIC - BASIC UNIT WITH ACCESSORIES


OPTION A PUMP CASE COOLING (7.5HP-25HP ONLY) OPTION H PRESSURE FILTER
OPTION B PUMP CASE COOLING OPTION J 2" COUPLING FOR C/S HEATER
OPTION C SYSTEM COOLING/FILTER LOOP OPTION K PUMP OUTLET CHECK VALVE
OPTION L BYPASS CHECK-RETURN HT. EX. ONLY
OPTION E RETURN LINE WATER/OIL HEAT EXCHANGER OPTION N RETURN FILTER-DUAL ELEMENT
OPTION F WATER TEMPERATURE MODULATING VALVE OPTION R* COMBINATION LEVEL/TEMPERATURE SWITCH

M M

A B OPTION
4.5 GPM @ 1.750 RPM

M C OPTION
SEE MANIFOLD 4.5 GPM @ 1.750 RPM
OPTIONS
P T
H L N

K E
SEE F
M COMPENSATOR
OPTIONS

HYDRAULIC SCHEMATIC

Parker Hannifin Corporation


Hydraulic Pump and
50 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US
Catalog HY13-1552-002/US,EU Low Profile Power Units Hydraulic Power Units
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

Dimensions – Accessories
V8 Reservoir with "Omit" Manifold Shown
Inch equivalents for millimeters dimensions are shown in (**). Installation information is for reference only. Consult
factory or visit Parker's Econfigurator for detailed information.

HEAT REMOVAL OPTION A .6 KW (.80 HP*)

HEAT REMOVAL OPTION B 1.1 KW (1.5 HP*)

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.

PUMP COMPENSATOR

PUMP COMPENSATOR
CONTROL

CONTROL
PUMP PRIME

PUMP PRIME
T T

P P

SAFETY RELIEF SAFETY RELIEF


DO NOT ADJUST DO NOT ADJUST

129.8
(5.11)
85.9
(3.38)

V-PAK V-PAK

Option "A" Cooling Loop Option "B" Cooling Loop


5.6 KW - 18.6 KW (7.5 HP - 25 HP) ONLY

11 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin
Parker HannifinCorporation
Corporation Marysville, Ohio USA
Hydraulic Pump
Hydraulic PumpDivision
and
Power Systems
Marysville, Division
Ohio USA 51
Marysville, Ohio USA
35
HY28-2661-CD/US
Catalog HY13-1552-002/US,EU Low Profile Power Units Hydraulic Power Units
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

Dimensions – Accessories
V8 Reservoir with "Omit" Manifold Shown
Inch equivalents for millimeters dimensions are shown in (**)
Ordering Note: Units with PVP76 pumps and requiring options "A", "B" or "C" can only be ordered with
V8 (302.8 L/80 Gal.) reservoir.

HEAT REMOVAL OPTION C 3.4 KW (4.5 HP*)

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.

PUMP COMPENSATOR
CONTROL
PUMP PRIME

OUT

IN

SAFETY RELIEF
DO NOT ADJUST

415.3
(16.35)

3/4" HALF COUPLING


INCLUDING WITH OPTION “C”
V-PAK

Option "C" System Cooling/Filter Loop

12 Parker Hannifin Corporation


Hydraulic Pump Division
ParkerHannifin
Parker
Marysville, Ohio USA HannifinCorporation
Corporation
HydraulicPump
Hydraulic PumpandDivision
52
38 Marysville,
Power SystemsOhioDivision
USA
Marysville, Ohio USA
HY28-2661-CD/US
HY28-2661-CD/US
Catalog HY13-1552-002/US,EU Low Profile Power Units Hydraulic Power Units
Technical Information
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series

Dimensions
Dimensions–­ Accessories
Accessories
V8 Reservoir with E, F, H, J, N & R Options Shown
Inch equivalents for millimeters dimensions are shown in (**).

"H" OPTION FILTER

PUMP COMPENSATOR
CONTROL
GPM
GAL

PSI
Fluidpower

HYDRAULIC PUMP/MOTOR DIVISION


Systems

OTSEGO MICH 49078 USA


MODEL NUMBER

TANK

PRESSURE MAX
PUMP FLOW
S/N
OPTION “N”
OPTION "R"
T

RETURNTEMP/LEVEL
COMBINATION FILTER SWITCH SAFETY RELIEF
DO NOT ADJUST

(1/2 NPT ELEC. CONN.)

"N" OPTION FILTER

470
(18.5) OPTION “F”
WATER VALVE

OPTION “E”
13.4KW (18HP) HEAT
REMOVAL @ GPM

13 Parker Hannifin Corporation


Hydraulic Pump Division
Parker HannifinCorporation
Parker Hannifin Corporation Marysville, Ohio USA
Hydraulic Pump
Hydraulic PumpDivision
and
Power Systems
Marysville, Division
Ohio USA 53
Marysville, Ohio USA
37
HY28-2661-CD/US Hydraulic Power Units
Technical Information V-Pak Low Profile Series

Perfomance Data — Maxiumum Working Pressure

Parker Hannifin Corporation


Hydraulic Pump and
54 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information V-Pak Low Profile Series

Perfomance Data — Maxiumum Working Pressure

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 55
Marysville, Ohio USA
HY28-2661-CD/US
Low Profile Power Units Hydraulic Power Units
Catalog HY13-1552-002/US,EU
Technical Information VolumeV-Paks
Series Control V-Pak Low Profile Series
Technical Information

Performance Data
Data-–Maximum
MaximumWorking
Working Pressure
Pressure

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum
relief valve or compensator setting.
**** Represents maximum operating pressure with pump/motor combination. When used on power unit
products this will represent a 207 bar (3000 psi) relief valve or compensator setting.

V-Pak Low Profile - Pump/Motor Combinations Maximum Operating Pressure


Bar (PSI)

FLOW LPM (GPM) 5.6 KW 7.5 KW 11.2 KW 14.9 KW 18.6 KW 22.3 KW 29.8 KW
PUMP
@ 1725 RPM (7.5 HP) (10 HP) (15 HP) (20 HP) (25 HP) (30 HP) (40 HP)

20.7 31.7 55.2 78.6 100 121.3 167.2


PVP76 90.8 (24.0)
(300) (460) (800) (1140) (1450) (1760) (2425)

20 31 53.4 75.8 96.5 117.2 160.3


PVP76 94.6 (25.0)
(290) (450) (775) (1100) (1400) (1700) (2325)

18.6 29.6 52.4 73.8 94.5 113.8 155.8


PVP76 98.4 (26.0)
(270) (430) (760) (1070) (1370) (1650) (2260)

17.9 29.3 50.3 71 91.4 113.8 155.8


PVP76 102.2 (27.0)
(260) (425) (730) (1030) (1325) (1650) (2260)

17.6 27.6 48.3 68.3 88.3 106.5 144.1


PVP76 106.0 (28.0)
(255) (400) (700) (990) (1280) (1545) (2090)

17.2 26.9 46.5 65.5 86.9 104.5 140.7


PVP76 109.8 (29.0)
(250) (390) (675) (950) (1260) (1515) (2040)

26.9 45.5 63.8 83.4 103.4 137.9


PVP76 113.6 (30.0) -
(390) (660) (925) (1210) (1500) (2000)

25.9 43.8 61.4 80.7 97.9 132.4


PVP76 117.3 (31.0) -
(375) (635) (890) (1170) (1420) (1920)

24.8 42.7 60.3 78.6 95.1 128.6


PVP76 121.1 (32.0) -
(360) (620) (875) (1140) (1380) (1865)

23.4 41.4 57.9 75.8 92.4 124.8


PVP76 124.9 (33.0) -
(340) (600) (840) (1100) (1340) (1840)

22.4 39.6 56.9 74.1 90.3 121.7


PVP76 128.7 (34.0) -
(325) (575) (825) (1075) (1310) (1765)

21.4 36.5 55.2 70.7 87.9 118.9


PVP76 132.5 (35.0) -
(310) (530) (800) (1025) (1275) (1725)

20.7 35.2 53.1 68.9 84.8 111


PVP76 136.7 (36.0) -
(300) (510) (770) (1000) (1230) (1610)

16 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin Corporation
Marysville, Ohio USAParker Hannifin Corporation
Hydraulic
HydraulicPump
PumpandDivision
56
42 Power Systems
Marysville, OhioDivision
USA
Marysville, Ohio USA
HY28-2661-CD/US Low Profile Power Units Hydraulic Power Units
Catalog HY13-1552-002/US,EU
Technical Information
Technical Information Volume Control
Series V-Paks V-Pak Low Profile Series

V-Pak Low
Low Profile
Profile
Performance
V-Pak Performance Data
Data Performance
Fluid Standard Hydraulics Oil 100 SSU @ 49°C (120°F)

Flow, Horsepower and Efficiency Charts

PVP33 @ 1800 RPM LPM GPM PVP48 @ 1800 RPM KW HP


LPM GPM Volumetric Efficiency 100 90.9 24 44.8 60.0
100 75.7 20
Flow cy
90 79.5 21 Efficien

Efficiency - %
Efficiency - %

90 68.2 18
Overall Efficiency
80 60.6 16 80 68.1 18 33.6 45.0
Flow
70 53.0 14 60.6 16
70

Flow

Power
60 45.4 12

r
60 45.4 12 22.4 30.0

we
KW HP
Flow

Po
50 37.9 10 29.8 40.0

ow
50 34.1 9
ow

Fl
30.3 8 l 23.9 32.0
ll F

ll
Fu
Fu 22.7 6 11.2 15.0
at
Power

22.7 6 17.9 24.0


r
o we
15.1 4 tP 11.9 16.0 11.4 3
Power
Inp
u
Compensated
7.6 2 6.0 8.0 0 0 0 0
wer
Compensated Po Bar 0 69 138 207 275
0 0 0 0 PSI 0 1000 2000 3000 4000
Bar 0 69 138 207 275
PSI 0 1000 2000 3000 4000
Pressure
Pressure

NOTE: The efficiencies and data in the graph are


good only for pumps running at 1800 RPM and
stroked to maximum. To calculate approximate
horsepower for the other conditions, use the following
formula:

HP =
[ Q x (PSI)
1714 ] + (CHp)

Actual GPM is directly proportional to drive speed


and maximum volume setting. Flow loss, however, is
a function of pressure only.

WHERE:
Q = Actual Output Flow in GPM
PSI = Pressure at Pump Outlet
CHp = Input Horsepower @ Full Compensation @
1800 RPM (from graph read at operating
pressure)

NOTE: Maximum input HP to the pump may exceed


electric motor drive capability. Select motor size (HP)
to exceed application requirements (HP).

17 Parker Hannifin Corporation


Hydraulic Pump Division
Parker Hannifin
Hannifin Corporation
Corporation Marysville, Ohio USA
Hydraulic Pump
Hydraulic PumpDivision
and
Marysville,
Power Ohio USA
Systems Division 57
41
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Technical Information V-Pak Low Profile Series

Catalog HY13-1552-002/US,EU Low Profile Power Units


V-Pak
Technical Low Profile Performance Data
Information —V-Paks
Volume
Series Heat Exchangers
Control

RESERVOIR SIZE LITERS (GALLONS)


Heat removal is based on static
303 (80)
ambient air of 29°C (85°F) and max. oil
.89 (1.2) temperature of 57°C (135°F).
KW (HP) REMOVAL

Parker
ParkerHannifin
HannifinCorporation
Corporation
Hydraulic
HydraulicPump
Pump and
Division
58
42 Power Systems
Marysville, OhioDivision
USA
18 Parker Hannifin Corporation Marysville, Ohio USA
Hydraulic Pump Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Additional Installation
Catalog HY28-2661-CD/US Information Vertical Power Units Series D, H, V-Packs
Installation Information VolumeD,
Series Control
H, V-Paks

Operating Notes
• Jog the electric motor once and verify that the • It is recommended that every 4,000 operating hours
electric motor is rotating in the same direction as the or once a year, whichever occurs first, the filler/
arrow on the electric motor housing. If direction is breather cap and suction strainer should be replaced.
incorrect, reverse two of the three leads on a
3-phase electric motor.
Fluid Recommendations
• D & H-Pak power units are tested and relief valve Premium quality hydraulic oil with a viscosity range
is set at maximum pressure of the pump/motor between 150-250 SSU (30-50 cst.) at 100°F (38°C).
combination. Normal operating viscosity range between 80-1000 SSU
• V-Pak power units are tested and pressure control (17-180 cst.). Maximum start-up viscosity is 4000 SSU
valves are factory preset. If adjustments are needed, (1000 cst.).
follow the procedure below: Begin adjusting relief NOTE: Consult Parker when exceeding 160°F (71°C)
valve and pump compensator control valve to operation. Oil should have maximum anti-wear
increase pressure gradually. (NOTE: Always set relief properties, rust and oxidation treatment.
valve 250 PSI higher than pump compensator
pressure control valve or severe overheating will
occur.) Filtration
For maximum pump and system component life, the
• If pump fails to prime, vent pump discharge to
system should be protected from contamination at a
atmosphere to establish fluid flow.
level not to exceed 125 particles greater than 10 microns
• Reservoir temperature should not exceed 66°C (150°F). per milliliter of fluid. (SAE Class 4 / ISO 16/13.) Due to
System reliability and component service life will be the nature of variable displacement pumps, variations
reduced when system is operated at higher in pump inlet conditions, fluid acceleration losses,
temperature. system aeration, and duty cycle must be carefully
considered before specifying suction line filtration.
• Clean fluid = improved system reliability and longer Contact your Parker representative for assistance.
component service life, change filter elements
whenever filter indicators indicate a dirty element NOTE: For additional information refer to latest edition
condition. of Bulletin No. HY13-2600-550-xxx..

28 Parker Hannifin Corporation


Parker Hannifin Corporation Hydraulic Pump Division
Hydraulic Pump and Maryville, Ohio USA
Power Systems Division 59
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Additional Technical
Catalog HY28-2661-CD/US Information Vertical Power Units Pump Mounting Adapters
Technical Information VolumeMounting
Pump Control Adapters

The totally enclosed pump mounting bracket offers


precision shaft alignment and safety from the
rotating shafts and coupling. The bracket is
designed to mount on the motor face with the motor
coupling half secure to the shaft. Then the pump,
with its coupling half secure on the pump shaft, is
mounted and the coupling halves are engaged.
This will require proper spacing of the coupling
prior to installation and a coupling with an outside
diameter less than “P” dimension. If the coupling
selected cannot be assembled this way, both
coupling halves must be installed on the motor
shaft. Next, mount the adapter on the motor. Then
the pump can be mounted and the coupling
secured to the pump by using the access slot to
tighten the pump shaft coupling set screw.

Dimensions*
Pump Mounting Adapter

STYLE 1 ADAPTER STYLE 2 ADAPTER


(SEE CHART FOR MOUNTING ORIENTATION) (VERTICAL MOUNT ONLY)
M DIA THRU
M DIA THRU EQUALLY SPACED
EQUALLY SPACED ON C2 DIA. B.C.
ON C1 DIA. B.C. (4 PLACES) 45
(4 PLACES)
45 ACCESS SLOT
ACCESS SLOT

G
A G A
DIA. D P B DIA. D P B
DIA. DIA. DIA. DIA.
DIA. DIA.
G
G

FACE TO FACE H THREAD


2 PLACES
FACE TO FACE
(56C FRAME) FACE TO FACE
H THREAD
2 PLACES
M DIA THRU
EQUALLY SPACED
ON C1 DIA. B.C.
(4 PLACES)

Model Pump Motor Face to Vertical Horizontal


A B C1 C2 D G H M P Style Weight
Number Mounting Mounting Face Mounting Mounting

876631 SAE AA 56C 6.7 5.0 5.88 N/A 4.50 3.50 1.63 3/8-16 0.44 2.00 YES YES 1 3 lb.

876632 SAE AA 182TC/256TC 9.0 5.3 7.25 N/A 8.50 5.00 1.63 3/8-16 0.56 2.00 YES YES 1 4 lb.

876633 SAE A 56C 6.7 5.0 5.88 N/A 4.50 4.25 2.10 3/8-16 0.44 3.25 YES YES 1 4 lb.

876634 SAE A 182TC/256TC 9.0 5.3 7.25 N/A 8.50 5.00 2.10 3/8-16 0.56 3.25 YES YES 1 4 lb.

876635 SAE A 182TC/256TC 9.0 5.3 7.25 N/A 8.50 5.88 2.10 3/8-16 0.56 3.25 YES YES 1 5 lb.

875343 SAE B 182TC/256TC 11.4 9.0 7.25 10.25 8.50 5.75 2.88 1/2-13 0.53 4.00 YES NO 2 7 lb.

875344 SAE B 182TC/256TC 11.4 9.0 7.25 10.25 8.50 6.81 2.88 1/2-13 0.53 4.00 YES NO 2 8 lb.

876683 SAE B 182TC/256TC 9.0 8.8 7.25 N/A 8.50 6.38 2.88 1/2-13 0.53 4.00 NO YES 1 7 lb.

876684 SAE C 182TC/256TC 9.0 9.3 7.25 N/A 8.50 6.69 3.56 5/8-11 0.53 5.00 NO YES 1 20 lb.

* All dimensions are in inches.

NOTE: It is the responsibility of the user to check the listed dimensions to ensure suitability of mounting adapter with pump/coupling/motor combination.

29 Parker Hannifin Corporation


Parker Hannifin Corporation
Hydraulic Pump Division
Maryville, Ohio USAHydraulic Pump and
60 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Conversion Equations
Catalog HY28-2661-CD/US Vertical Power Units D, H and V-Pak Series
Volume Control
Conversion Equations

Application Formulas
• 1 GPM at 1500 PSI = 1 HP (General Rule) • 1 HP = 42.4 BTU/Min.
• 1 Gallon = 231 Cubic Inches (3.7854 Liters) • 1 Gallon = 3.7854 Liters
• 1 Gallon Oil = 7.08 Lbs.
• 1 bar = 14.5 PSI
• 25.4mm = 1 Inch

GPM x PSI
HP =
1714 x Pump Efficiency

1714 x Pump Efficiency x HP


PSI =
GPM

1714 x Pump Efficiency x HP


GPM =
PSI

Torque (in.-lbs.) x RPM


HP =
63025

HP x 63025
Torque =
RPM

HP x 63025
RPM =
Torque

Motor Information
At 440V — 3-Phase Motor Draws 1.25 AMP/HP
At 220V — 3-Phase Motor Draws 2.5 AMP/HP
At 110V — Single Phase Motor Draws 10 AMP/HP

30 Parker Hannifin Corporation


Parker Hannifin Corporation Hydraulic Pump Division
Hydraulic Pump and Maryville, Ohio USA
Power Systems Division 61
Marysville, Ohio USA
HY28-2661-CD/US Hydraulic Power Units
Notes

Parker Hannifin Corporation


Hydraulic Pump and
62 Power Systems Division
Marysville, Ohio USA
HY28-2661-CD/US
Offer of Sale

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”)
are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and
Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work
described will be referred to as “Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise,
Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms Seller shall retain a security interest in the goods delivered and this agreement shall be
and Conditions and to the terms and conditions found on-line at www.parker.com/ deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes
saleterms/. Seller objects to any contrary or additional term or condition of Buyer’s Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems
order or any other document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien
2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any
of this document are valid for 30 days. After 30 days, Seller may change prices to reflect amounts owed to Seller by Buyer.
any increase in its costs resulting from state, federal or local legislation, price increases 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller
from its suppliers, or any change in the rate, charge, or classification of any carrier. The harmless from any claim, liability, damages, lawsuits, and costs (including attorney
prices stated on the reverse or preceding pages of this document do not include any fees), whether for personal injury, property damage, patent, trademark or copyright
sales, use, or other taxes unless so stated specifically. Unless otherwise specified by infringement or any other claim, brought by or incurred by Buyer, Buyer’s employees,
Seller, all prices are F.O.B. Seller’s facility, and payment is due 30 days from the date or any other person, arising out of: (a) improper selection, improper application or other
of invoice. After 30 days, Buyer shall pay interest on any unpaid invoices at the rate of misuse of Products purchased by Buyer from Seller; (b) any act or omission, negligent
1.5% per month or the maximum allowable rate under applicable law. or otherwise, of Buyer; (c) Seller’s use of patterns, plans, drawings, or specifications
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and furnished by Buyer to manufacture Product; or (d) Buyer’s failure to comply with these
Seller shall not be responsible for any damages resulting from any delay. Regardless of terms and conditions. Seller shall not indemnify Buyer under any circumstance except
the manner of shipment, title to any products and risk of loss or damage shall pass to as otherwise provided.
Buyer upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). 13. Cancellations and Changes. Orders shall not be subject to cancellation or change
Unless otherwise stated, Seller may exercise its judgment in choosing the carrier and by Buyer for any reason, except with Seller’s written consent and upon terms that will
means of delivery. No deferment of shipment at Buyers’ request beyond the respective indemnify, defend and hold Seller harmless against all direct, incidental and conse-
dates indicated will be made except on terms that will indemnify, defend and hold Seller quential loss or damage. Seller may change product features, specifications, designs
harmless against all loss and additional expense. Buyer shall be responsible for any and availability with notice to Buyer.
additional shipping charges incurred by Seller due to Buyer’s changes in shipping, 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this
product specifications or in accordance with Section 13, herein. agreement without the prior written consent of Seller.
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects 15. Entire Agreement. This agreement contains the entire agreement between the
in material or workmanship for a period of eighteen months from the date of delivery Buyer and Seller and constitutes the final, complete and exclusive expression of the
to Buyer. The prices charged for Seller’s products are based upon the exclusive terms of the agreement. All prior or contemporaneous written or oral agreements or
limited warranty stated above, and upon the following disclaimer: DISCLAIMER OF negotiations with respect to the subject matter are herein merged.
WARRANTY: THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY 16. Waiver and Severability. Failure to enforce any provision of this agreement will
PERTAINING TO PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL not waive that provision nor will any such failure prejudice Seller’s right to enforce that
OTHER WARRANTIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY provision in the future. Invalidation of any provision of this agreement by legislation or
AND FITNESS FOR A PARTICULAR PURPOSE. other rule of law shall not invalidate any other provision herein. The remaining provisions
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon of this agreement will remain in full force and effect.
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 17. Termination. This agreement may be terminated by Seller for any reason and at
days of delivery. No other claims against Seller will be allowed unless asserted in writing any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller
within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 may by written notice immediately terminate this agreement for the following: (a) Buyer
days after the date within the warranty period on which the defect is or should have commits a breach of any provision of this agreement (b) the appointment of a trustee,
been discovered by Buyer. Any action based upon breach of this agreement or upon receiver or custodian for all or any part of Buyer’s property (c) the filing of a petition
any other claim arising out of this sale (other than an action by Seller for any amount for relief in bankruptcy of the other Party on its own behalf, or by a third party (d) an
due to Seller from Buyer) must be commenced within thirteen months from the date of assignment for the benefit of creditors, or (e) the dissolution or liquidation of the Buyer.
tender of delivery by Seller or, for a cause of action based upon an alleged breach of 18. Governing Law. This agreement and the sale and delivery of all Products here-
warranty, within thirteen months from the date within the warranty period on which the under shall be deemed to have taken place in and shall be governed and construed
defect is or should have been discovered by Buyer. in accordance with the laws of the State of Ohio, as applicable to contracts executed
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, and wholly performed therein and without regard to conflicts of laws principles. Buyer
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts
IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, of Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising out
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT of or relating to this agreement. Disputes between the parties shall not be settled by
OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF arbitration unless, after a dispute has arisen, both parties expressly agree in writing to
THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES arbitrate the dispute.
OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, EVEN IF 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER LEGAL liability for infringement of any patents, trademarks, copyrights, trade dress, trade
THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY CLAIM MADE BY secrets or similar rights except as provided in this Section. Seller will defend and
BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. indemnify Buyer against allegations of infringement of U.S. patents, U.S. trademarks,
7. Contingencies. Seller shall not be liable for any default or delay in performance if copyrights, trade dress and trade secrets (“Intellectual Property Rights”). Seller will
caused by circumstances beyond the reasonable control of Seller. defend at its expense and will pay the cost of any settlement or damages awarded in
8. User Responsibility. The user, through its own analysis and testing, is solely an action brought against Buyer based on an allegation that a Product sold pursuant to
responsible for making the final selection of the system and Product and assuring that this Agreement infringes the Intellectual Property Rights of a third party. Seller’s obliga-
all performance, endurance, maintenance, safety and warning requirements of the tion to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten (10)
application are met. The user must analyze all aspects of the application and follow days after Buyer becomes aware of such allegations of infringement, and Seller having
applicable industry standards and Product information. If Seller provides Product or sole control over the defense of any allegations or actions including all negotiations
system options, the user is responsible for determining that such data and specifica- for settlement or compromise. If a Product is subject to a claim that it infringes the
tions are suitable and sufficient for all applications and reasonably foreseeable uses of Intellectual Property Rights of a third party, Seller may, at its sole expense and option,
the Products or systems. procure for Buyer the right to continue using the Product, replace or modify the Product
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confi- so as to make it noninfringing, or offer to accept return of the Product and return the
dential information or equipment furnished by Buyer or any other items which become purchase price less a reasonable allowance for depreciation. Notwithstanding the
Buyer’s property, may be considered obsolete and may be destroyed by Seller after foregoing, Seller shall have no liability for claims of infringement based on information
two consecutive years have elapsed without Buyer placing an order for the items which provided by Buyer, or directed to Products delivered hereunder for which the designs
are manufactured using such property. Seller shall not be responsible for any loss or are specified in whole or part by Buyer, or infringements resulting from the modification,
damage to such property while it is in Seller’s possession or control. combination or use in a system of any Product sold hereunder. The foregoing provisions
10. Special Tooling. A tooling charge may be imposed for any special tooling, including of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole and
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. exclusive remedy for infringement of Intellectual Property Rights.
Such special tooling shall be and remain Seller’s property notwithstanding payment of 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise,
any charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging sales, use, property, occupational or like taxes which may be imposed by any taxing
to Seller which is utilized in the manufacture of the Products, even if such apparatus authority upon the manufacture, sale or delivery of Products.
has been specially converted or adapted for such manufacture and notwithstanding 21. Equal Opportunity Clause. For the performance of government contracts and
any charges paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, where dollar value of the Products exceed $10,000, the equal employment opportunity
discard or otherwise dispose of any special tooling or other property in its sole discre- clauses in Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and
tion at any time. 60-250.4, are hereby incorporated.

Parker Hannifin Corporation


Hydraulic Pump and
Power Systems Division 63
Marysville, Ohio USA
North America Truck Tel: (39) 02 45 19 21 Tel: (91) 22 5613 7081
Industrial USA The Netherlands Korea
USA Eastern Region Oldenzaal Seoul
Chicago Region Cleveland, OH Tel: (31) 541 585000 Tel: (82) 2 559 0400
Naperville, IL Tel: (440) 519 1125
Norway Malaysia
Tel: (630) 964 0796 Western Region Ski Subang Jaya
Great Lakes Region San Ramon, CA Tel: (47) 64 91 10 00 Tel: (60) 3 5638 1476
Fairlawn, OH Tel: (925) 735 9573
Tel: (330) 670 2680 Poland New Zealand
Canada
Warsaw Mt. Wellington
Northeast Region Milton, Ontario Tel: (48) 22 57 32400 Tel: (64) 9 574 1744
Lebanon, NJ Tel: (905) 693 3000
Tel: (908) 236 4121 Portugal Japan
México
Pacific Region Leca da Palmeira Tokyo
Apodaca, N.L. Tel: (351) 22 999 7360 Tel: (81) 3 6408 3900
Buena Park, CA Tel: (52) 81 8156 6000
Tel: (714) 228 2509 Romania Singapore
Southern Region Europe Bucharest Jurong Town
Alpharetta, GA Tel: (40) 21 252 1382 Tel: (65) 6 887 6300
Austria
Tel: (770) 619 9767 Wiener Neustadt Russia Taiwan
Canada Tel: (43) 2622 23501 0 Moscow Taipei
Milton, Ontario Belgium Tel: (7) 495 580 9145 Tel: (886) 2 2298 8987
Tel: (905) 693 3000 Nivelles Slovenia Thailand
México Tel: (32) 67 280 900 Novo Mesto Bangkok
Toluca, Edo. de Czech Republic and Tel: (386) 7 337 6650 Tel: (662) 717 8140
México Slovakia
Tel: (52) 72 2275 4200 Spain
Klecany Madrid Middle East
Tel: (420) 284 083 111 Tel: (34) 91 675 7300 United Arab Emirates
Mobile Denmark Abu Dhabi
Ballerup Sweden
USA Tel: (971) 2 678 8587
Tel: (45) 4356 0400 Spanga
Global Mobile Tel: (46) 8 597 95000
Lincolnshire, IL Finland Latin America
Tel: (847) 821 1500 Vantaa Ukraine
Kiev Pan American Division
Central Region Tel: (358) 20 753 2500
Tel: (380) 44 494 2731 Miami, FL
Lincolnshire, IL France Tel: (305) 470 8800
Tel: (847) 821 1500 Contamine-sur-Arve United Kingdom
Eastern Region Tel: (33) 4 50 25 80 25 Warwick, Argentina
North Canton, OH Tel: (44) 1926 317878 Buenos Aires
Germany Tel: (54) 33 2744 4129
Tel: (330) 284 3355
Kaarst
Midwest Region Tel: (49) 2131 4016 0 Asia Pacific Brazil
Hiawatha, IA Australia Cachoeirinha RS
Tel: (319) 393 1221 Greece
Athens Castle Hill Tel: (55) 51 3470 9144
Southern Region Tel: (30) 210 933 6450 Tel: (61) 2 9634 7777 Venezuela
Aledo, TX Caracas
Tel: (817) 441 1794 Hungary China
Beijing Tel: (58) 212 238 5422
Western Region Budapest
Tel: (36) 1 220 4155 Tel: (86) 10 6561 0520
Buena Park, CA Africa
Tel: (714) 228 2509 Ireland Shanghai
County Dublin, Baldon- Tel: (86) 21 5031 2525 South Africa
Canada Kempton Park
Milton, Ontario nell Hong Kong
Tel: (353) 1 466 6370 Tel: (852) 2428 8008 Tel: (27) 11 961 0700
Tel: (905) 693 3000
México Italy India
Apodaca, N.L. Corsico, Milano Mahape, Navi Mumbai
Tel: (52) 81 8156 6000
© 2016 Parker Hannifin Corporation, all rights reserved HY28-2661-CD/US
Supercedes All Previous Versions
04/2016
Parker Hannifin Corporation
Hydraulic Pump and Power Systems Division
14249 Industrial Parkway
Marysville, OH 43040 USA
phone 937 644 4435
fax 937 642 3639
www.parker.com/hps

You might also like