Professional Documents
Culture Documents
Search
● Contact us
Department of Engineering
IT Services
● University of Cambridge
● Department of Engineering
● Computing Help
● Programs
*CLOAD
100, 0., -100., 0.
101, 0., -80., 0.
If the same load is to be applied to a number of nodes then these nodes can be made into a set and single data line could be used
as follows :
The nodes listed are grouped together in a set called NDLSTA.
*NSET,NSET=NDLSTA
*CLOAD
NDLSTA, 0., -100., 0.
If using ABAQUS/CAE select module Load and click on the Create load icon. In the new form select Concentrated force and
click on Continue....
In the viewport area click on Points to be applied the Forces and then click on Done. Hold down the SHIFT key to make multiple
selections. Hold down the CTRL key to de-select any points previously selected.
In the dialogue box which pops up enter the load in the box for the appropriate directions, CF1, CF2 and CF3 are for X, Y and Z
directions respectively. Click on OK to complete the process.
Consider the figure where nodes 1 to 5 along the outer radius are to be subjected to a radial outward force of 1 unit. A local
cylindrical co-ordinate system transformation is set up first. The nodes 1 to 5 are grouped into an element set called CID1. The
transform keyword is used to apply the transformation to the node set CID1 as follows :
*NSET, NSET=CID1
1, 2, 3, 4, 5
**
**
** radial force
**
*CLOAD, OP=NEW
1, 1, 1.
2, 1, 1.
3, 1, 1.
4, 1, 1.
5, 1, 1.
If using ABAQUS/CAE folow select the Load module. Click on the Create Datum CSYS co-ordinate system. Choose the
appropriate icon from the collection of icons. In the dialogue box which pops up select the required co-ordinate system out of the
choice offered : Rectangular, cylindrical and spherical.
Then click on continue. Answer the questions posed in the prompt area and enter any values prompted for. Then click on the Red
cross to complete the process.
In the new form select Concentrated force and click on Continue....
In the viewport area click on Points to be applied the Forces and then click on Done. Hold down the SHIFT key to make multiple
selections. Hold down the CTRL key to de-select any points previously selected.
Click on the Edit button next to the Global CSYS entry and in the prompt area click on Datum CSYS List and this will list the
previously created co-ordinate system. Make the selection. Click on OK.
In the dialogue which pops up enter the load in the box for the appropriate directions, CF1, CF2 and CF3 represent the X, Y and
Z directions respectively. Click on OK to complete the process.
*DLOAD
40, P3, 50. (Element 40 Side 3 is subjected to 50 units of loading)
TOP, P3, 10. (Side 3 of all elements in set TOP is subjected to 10 units of loading)
For shell elements subjected to pressure loading use the following statements.
*DLOAD
SHLGB, P, 100.
Here the shell elements in element set SHLGB are subjected to 100 units of pressure loading in the direction of the positive
normal to the shell. To apply the loading in the opposite direction make the load magnitude negative.
If using ABAQUS/CAE follow the procedure above for Point Loads but select Pressure instead. Click Continue....
In the viewport area click on lines/edges (In 2D analysis) to be subjected to pressure and then click on Done. Hold down the
SHIFT key to make multiple selections. Hold down the CTRL key to de-select any points previously selected.
In the dialogue box which pops up enter the load in the box marked Magnitude.
If the loading is Uniform leave distribution at the default setting. For Hydro-static or User definedclick on the down arrow after
and make the selection.
For distribution click on Create and using the Create Expression Field and create an expression as a function of X and Y (for 2
Dimensional analysis). Then click OK.
*MATERIAL, NAME=STEEL
**
*ELASTIC, TYPE=ISO
3.E+7, 0.3
**
*DENSITY
7800.
*DLOAD
PLATE, GRAV, 9.8, 0.0, 0.0, -1.0
Here PLATE is the element set subjected to gravity loading which is defined by GRAV. For earth's gravity 9.8 is the actual
magnitude. This is followed by the components of the gravity vector in X, Y and Z directions respectively. Here gravity acts in
the negative Z direction.
For the axisymmetric case only the component 2 should be non-zero (-1).
If using ABAQUS/CAE select module Load and click on the Create load icon. In the new form select Gravity and click on
Continue....
In the viewport area click on the region to be applied the Gravity and then click on Done. Hold down the SHIFT key to make
multiple selections. Hold down the CTRL key to de-select any regions previously selected.
In the dialogue which pops up enter the load in the box for the appropriate directions, Component 1 2 and 3 represent X, Y and Z
directions respectively. Click on OK to complete the process.
If the amplitude of the loading is not the default Ramp then click on create and choose the appropriate amplitude from the
selection available and click on OK.
Define the element set to be subjected to the centrifugal loading. The magnitude is calculated as density multiplied by the square
of the angular velocity (in radians/second). For axisymmetric problems the axis of rotation must be the global Z-axis, which must
be specified as 0.0, 0.0, 0.0, 0.0, 1.0, 0.0.
*DLOAD
PLATE, CENT, 225., 0.0, 0.0, 0.0, 0.0, 1.0, 0.0
The value of 225 is arrived at from a density value of 9 multiplied by the square of the angular velocity of 5 radians/sec.
If using ABAQUS/CAE select module Load and click on the Create load icon. In the new form select Rotational Body force
and click on Continue....
In the viewport area click on the region to be subjected to the Centrifugal force and then click on Done. ABAQUS/CAE will
prompt for 2 points to define the axis of rotation.
In the dialogue box select the toggle switch for Centrifugal for ther Load effect . Enter the value for Angular velocity and click
on OK.
If the amplitude of the loading is not the default Ramp then click on create and choose the appropriate amplitude from the
selection available and click on OK.
*CFLUX
*CFLUX
56, 11, 10.
57, 11, 10.
Nodes 56 and 57 are applied a heat flux of 10 units. The number 11 represents the temperature d.o.f.
*DFLUX
*DFLUX
100, SPOS, 10.
A uniform surface flux of 10.0 per unit area is applied to the top face (SPOS) of element 100 which is a general heat transfer shell
element.
*FILM
Example
*AMPLITUDE, NAME=sink
0.0, 0.5, 1.0, 0.9
*AMPLITUDE, NAME=famp
0.0, 1.0, 1.0, 22.0
...
**
*STEP
*HEAT TRANSFER
...
*FILM, AMPLITUDE=sink, FILM AMPLITUDE=famp
3, F2, 90.0, 2.0
file:///C|/Users/hamid/Desktop/CUED - ABAQUS.html (7 sur 17)02/07/2016 08:41:36
CUED - ABAQUS
A uniform, temperature-dependent film coefficient and a time-dependent sink temperature can be defined for face 2 of element 3
by
*AMPLITUDE, NAME=sink
0.0, 0.5, 1.0, 0.9
*FILM PROPRETY, NAME=filmp
2.0, 80.0
2.3, 90.0
8.5, 180.0
...
**
*STEP
*HEAT TRANSFER
...
*FILM, AMPLITUDE=sink
3, F2, 90.0, filmp
General
In the element type section in the ABAQUS user's manual the type of loading that can be applied is listed under each element
type category. This type of loading is only applicable to the following element types :
These categories of elements can be found under the following broader group of element types :
Look for the heading Distributed heat fluxes under the element group and these list the type of heat input that can be specified.
Shell Elements
The output (displacements, stresses) will reflect this interpretation. These (displacements, stresses) are calculated as changes from
the base state.
*CLOAD,OP=NEW
Here the time and the load scale factors are listed in pairs. For example :
*AMPLITUDE, NAME=UPDOWN
0., 0., 3.0, 1., 6.0, 1., 10., 0.
....
....
**
** step 1
**
*STEP,INC=50
*STATIC
0.1,5.0,
*DLOAD, AMPLITUDE=UPDOWN
TOP, P3, 1000.
*END STEP
**
** step 2
**
*STEP,INC=50
*STATIC
0.1,5.0,
file:///C|/Users/hamid/Desktop/CUED - ABAQUS.html (10 sur 17)02/07/2016 08:41:36
CUED - ABAQUS
*DLOAD, AMPLITUDE=UPDOWN
TOP, P3, 1000.
*END STEP
This first defines a time variation which rises linearly from a value of 0.0 at time zero to 1.0 at a time 3.0, remains at that value
until a time of 6.0, then ramps down to 0.0 at a time of 10.0 as shown in figure.
This time variation is called UPDOWN, and is referred to on a *DLOAD option, where it governs the behaviour of a pressure
load applied on side 1 (load type P1) of a set of elements called TOP. This magnitude will vary through time according to the
amplitude definition, so that, for example, at a time 1.5 the pressure will be 500. The magnitudes specified in the AMPLITUDE
option are used as scaling factors.
You will notice that because of the absence of the perturbation option in the *STEP keyword this is a general analysis where
time accumulates. Because the step time is only 5.0 the loading of 1000 is applied and the unloading phase has not begun. In the
second step which is also of duration of 5.0 units of time in the first 1.0 unit of time the loading remains unchanged. Then the
loading is gradually reduced and at the end of the step it has reached the unloaded stage.
From the above example it should be clear that the *AMPLITUDE specification if necessary can span across more than one step
in a general analysis.
If you are using the *AMPLITUDE option in a perturbation step then the time range cannot straddle more than one step.
However it is perfectly acceptable to use *AMPLITUDE when the time used is the step time. The example below shows such a
step. The amplitude definition UPDOWN remains unchanged. The following step has a step time of 10 units which is the same as
the time range specified in the amplitude definition.
**
** step 1
**
*STEP,PERTURBATION,INC=100
*STATIC
0.1,10.0,
*DLOAD, AMPLITUDE=UPDOWN
TOP, P3, 1000.
*END STEP
*CLOAD, OP=MODIFY
25, 0., -25.
Then the loading is modified for the listed nodes ONLY. At all other nodes the loading applied in the previous step using the
*CLOAD keyword (for this example) remains unchanged.
To reduce the level of the loading specify the new load level. Example :
*CLOAD, OP=MODIFY
25, 0., -10.
Here the load level is reduced from -25 to -10. Notice that these are TOTAL loads. Here the minus sign only specifies the
direction. One only considers the MAGNITUDE of the loading which always refers to the TOTAL load. With ABAQUS one
always specify the total value of the load and NOT the incremental load.
Q7.13 : How do I remove a single load which forms of group of loading which
has already been applied in a previous step?
In the step in which you want to remove the single load re-specify the group of loading except for the load to be removed with
the OP=NEW option. Here it is assumed that the type of loading is the same for the whole group (example : *CLOAD).
....
** step in which the group of loading is applied
**
*CLOAD
25, 0., -25.
50, 0., -25.
75, 0., -25.
100, 0., -25.
....
** step in which the load applied to node 25 is removed
*CLOAD, OP=NEW
50, 0., -25.
75, 0., -25.
100, 0., -25.
Which of these two forms the default option depends on the procedure used for the step and the type of loading. See section
10.1.1 of the ABAQUS User's manual (version 5.5) for further explanation.
*DLOAD
SHELL, BX, pressure-per-unit-thickness
SHELL is an element set consisting of all the shell elements subjected to pressure. The loading should be specified as a body
force. Therefore divide the pressure by the thickness of the shell elements.
Q7.17 : How do I specify a moving pressure loading (For example a wheel load
of a vehicle)?
For this the subroutine DLOAD is required and this is illustrated with the following example.