Applied Mathematical Modelling 30 (2006) 854–866

www.elsevier.com/locate/apm

CFD application for coal/air balancing in power plants


Sowjanya Vijiapurapu a, Jie Cui a,*
, Sastry Munukutla b

a
Mechanical Engineering Department, Tennessee Technological University, P.O. Box 5014, Cookeville, TN 38505, USA
b
Mechanical Engineering Department, Center for Energy Systems Research, Tennessee Technological University,
P.O. Box 5014, Cookeville, TN 38505, USA

Received 1 May 2004; received in revised form 1 May 2005; accepted 27 June 2005
Available online 18 August 2005

Abstract

Unbalanced coal/air flow in the pipe systems of coal-fired power plants will lead to non-uniform com-
bustion in the furnace, and hence a overall lower efficiency of the boiler. A common solution to this prob-
lem is to put orifices in the pipe systems to balance the flow. It is well known that if the orifices are sized to
balance clean air flow to individual burners connected to a pulverizer, the coal/air flow would still be unbal-
anced and vice versa. However, the current power industry practice throughout the world is to size orifices
for balancing the clean air flow and accept the resulting imbalance in coal/air flow. Field tests are mostly
conducted to verify a balanced clean air flow.
It is now proposed to size the orifices for balancing the coal/air flow and then calculate the unbalanced
clean air flow distribution to be known as the ‘‘tailored clean air flow’’. Commercially available Computa-
tional Fluid Dynamics (CFD) code CFX was used to simulate the complex flows in the piping systems in a
power plant. The two-phase modelling technique was employed to estimate the pressure drop coefficients
with both clean air and coal/air flows in order to size the orifices. The results indicate that the pressure drop
is strongly dependent on the piping system geometry. With this proposed method, field tests can be con-
ducted to correspond with the tailored clean air flow, and the coal/air flow balancing would be achieved.
 2005 Elsevier Inc. All rights reserved.

Keywords: CFD; Numerical modelling; Coal/Air balancing; Power plant

*
Corresponding author. Tel.: +1 931 372 3357; fax: +1 931 372 6340.
E-mail address: jiecui@tntech.edu (J. Cui).

0307-904X/$ - see front matter  2005 Elsevier Inc. All rights reserved.
doi:10.1016/j.apm.2005.06.005
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 855

1. Introduction

There are a number of operational problems of coal-fired boilers, which are suspected to be
caused by non-uniform combustion in the furnace. One source of non-uniform combustion is un-
even distribution of fuel inputs to the furnace. Several coal pipes connect the exit of the pulverizer
to the individual burners, all of which are located at the same elevation in the furnace for that
particular pulverizer [1]. Though the elevation change is identical for each system, the pipes have
different horizontal, vertical, and inclined lengths, and bends. Thus, the resistance to flow is dif-
ferent for each system, leading to uneven distribution.
The resistance of a system is different for single-phase flow (clean air) or two-phase flow (coal/
air) [2]. The resistance is expressed as a dimensionless pressure drop coefficient. Thus, the single-
phase and the corresponding two-phase pressure drop coefficients for any given system are differ-
ent. One significant point is that the pressure drop coefficient for a sharp edged orifice is the same
for both single-phase and two-phase flows for dilute suspension flows encountered in power
plants. A typical volume fraction of coal to air is 1/1600 [3].
Since the resistance coefficients are different for clean air and coal/air flows, the orifice sizes
needed to balance the clean air flow would be different from the orifice sizes needed to balance
the coal/air flow. The electric power industry practice throughout the world so far has been to size
the orifices based on clean air flow pressure drop coefficients. The clean air flow would, therefore,
be balanced but the corresponding coal/air flow would still be unbalanced. In one instance, it was
reported that after the clean air flow was balanced to within 3%, the coal/air flow was still unbal-
anced by 27% [4]. On the other hand, if the orifice sizing is based on the coal/air flow balancing,
the corresponding clean air flow would be unbalanced. This would not present a problem since
coal/air balancing is what is needed for efficient combustion.
For calculating the pressure drop coefficients, standard handbook data can be used [5]. How-
ever, the data for two-phase flow (coal/air) is found to be unreliable. So, the pressure drop coef-
ficients for the coal/air as well as the clean air flow were calculated using CFD in the present work
[6]. The multi-phase models were used to simulate the complex flow field of each phase and the
interaction between air and coal particles. It is believed that the numerical solution was able to
provide reasonable pressure drop coefficients in the current study.
In most power plants the geometry for individual pipe systems is specified by the total horizon-
tal run, total vertical run, number of bends, and bend geometry. Since exact geometry of the sys-
tem is not specified, it is not possible to calculate the pressure drop of the entire system in one
pass. It was therefore decided to calculate the pressure drop in a system by breaking it into indi-
vidual components. The calculated pressure drops across various components were then added
together, to estimate the pressure drop of the entire system. In the current paper, this procedure
will be implemented in one of the coal-fired electric utilities. A description of this method and
results from field experience will form the rest of the contents of this paper.

2. Use of CFD in power industry applications

In the power generation industry, many processes involve multi-phase flow, phase transforma-
tion, combustion, and complex chemical reactions [7]. This is particularly true for coal fired power
856 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

plants. However, due to the complex nature of these phenomena, traditional research approaches
were not adequate in providing a thorough understanding of these processes. Recently, CFD has
been used in power industry to gain a qualitative as well as quantitative understanding of these
processes.
Pulverized coal combustion in a 2.5 MW burner was modelled using two commercial CFD
codes [8]. Despite discrepancies between the solutions of the two codes, the predicted velocity,
temperature, and species concentration were in overall agreement with the experimental data, sug-
gesting that the two codes were capable of predicting good ÔtrendÕ solutions. The Eulerian–Eule-
rian multi-phase model in conjunction with the k–e model was applied to predict erosion in slurry
pipeline tee-junctions [9]. The CFD model was used to assess several potential solutions to the ero-
sion problem, and the results demonstrated the effectiveness with which CFD techniques can be
used in industrial applications. Similar multi-phase model was employed to develop a computa-
tional model of erosion in a fluidized bed [10]. It was shown that the model predictions were in
good agreement with the experiment results. Stopford reviewed some of the recent applications
of CFD to the power generation and combustion industries [11]. Examples included coal-fired
low-NOx burner design, furnace optimization, over-fire air, gas reburn, and laminar flames.
The results showed that CFD modelling was well established as a design tool and has been widely
used in the power generation industry to help engineers reduce emissions, increase thermal effi-
ciency, select fuel, and extend plant lifetime.
In this paper, an attempt will be made to take this new approach—CFD—to a problem faced
by the power industry for a number of years: coal/air balancing. The multi-phase model in the
unstructured version of CFX (version 5.5.1) will be applied to determine pressure drop in the pip-
ing systems in a power plant. Based on the predicted pressure drop, orifices in the piping systems
will be added or modified and balanced coal/air flow will be achieved.

3. Principle of the method

Fig. 1 shows two systems with the same elevation change, but different horizontal, vertical runs,
and bends. Both systems start at the same elevation at the pulverizer exit and discharge at the same
elevation in the boiler. System 1 has one vertical run, one horizontal run, and one bend. System 2
has 3 vertical runs, 3 horizontal runs, and 5 bends. The total pressure drop consists of frictional
loss over the horizontal and vertical pipe lengths, a loss due to bends, and a loss due to gravity.
In general if the total flow rate is Q, with flow rate in system 1 being Q1 and that in system 2
being Q2, and the pressure drop coefficients being K1 and K2, respectively, we have
Q ¼ Q1 þ Q2 ;
K 1 Q21 ¼ K 2 Q22 ;
ð1Þ
Q Q
) Q2 ¼ qffiffiffiffi and Q1 ¼ qffiffiffiffi .
1 þ KK 21 1 þ KK 12

Let the pressure drop coefficients for clean air and coal/air for systems 1 and 2 be K1A, K2A, and
K1C, K2C respectively. Then the flow distribution with clean air is given as
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 857

Fig. 1. Illustration of two systems with the same elevations change, but different horizontal and vertical runs, and
bends.

Q Q
Q2A ¼ qffiffiffiffiffiffi and Q1A ¼ qffiffiffiffiffiffi ð2Þ
K 2A K 1A
1þ K 1A
1þ K 2A

and that with coal/air is given as


Q Q
Q2C ¼ qffiffiffiffiffiffi and Q1C ¼ qffiffiffiffiffiffi . ð3Þ
K 2C K 1C
1þ K 1C
1þ K 2C

In most cases, it has been observed that the ratio of K2C/K1C is very nearly equal to K2A/K1A. In
other words, clean air and coal/air are unbalanced in a similar manner. The pressure drop coef-
ficient KOR of the orifice plate is calculated as the absolute difference in the pressure drop coeffi-
cients of the pipes. In order to achieve clean air balance, an orifice yielding a pressure drop
coefficient of KOrf,A = K2A  K1A should be introduced. In order to achieve coal/air balance,
an orifice yielding a pressure drop coefficient of KOrf,C = K2C  K1C should be introduced.
As a general rule the pressure drop coefficients for the coal/air (two-phase) flow K1C and K2C,
are always greater than the corresponding clean air (single-phase) pressure drop coefficients K1A
and K2A (typically by a factor of 2–3) [12]. Hence, the orifice diameters based on the clean air dis-
tribution are larger than those based on the coal/air distributions. As a result of the above, it has
been a normal trend in the power industry to under estimate the pressure drop requirement.
The diameter of the orifice can be calculated from available empirical equations [13], one of the
commonly used equations is
"   0.375 !#2
F1 F0 F0
K OR ¼  1 þ 0.707  1 ; ð4Þ
F0 F1 F1
 2
where FF 01 ¼ AA01 ¼ DD01 , A0, A1 correspond to the area of the orifice and pipe, respectively, and, D0,
D1 correspond to the diameters of the orifice and pipe, respectively.
858 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

4. The systems modelled

The four systems modelled using the numerical method are given in Table 1. As shown in the
Table, there are 4 systems that carry coal/air mixture from the pulverizer to the furnace. The indi-
vidual lengths of the horizontal and vertical sections between the bends are not known. The only
data available is the total horizontal and vertical length of the systems, and the number of differ-
ent bends in each system. Also, the bend angles for each system are known.
If K1, K2, K3, and K4 are the pressure drop coefficients for systems 1, 2, 3, and 4, respectively,
flow distributions V1, V2, V3, and V4 can be calculated by extending Eq. (3) to a 4-branch system.
rffiffiffiffiffiffi
400 K1
V 1 ð%Þ ¼ qffiffiffiffi qffiffiffiffi qffiffiffiffi ; V 2 ð%Þ ¼ V 1 ;
K1
1 þ K2 þ K3 þ K4K1 K1 K2
rffiffiffiffiffiffi rffiffiffiffiffiffi
K1 K1
V 3 ð%Þ ¼ V 1 ; V 4 ð%Þ ¼ V 1 . ð5Þ
K3 K4
Note that for a perfectly balanced system K1 = K2 = K3 = K4, and in that case V1 =
V2 = V3 = V4 = 100%. For an unbalanced system V1, V2, V3, and V4 could be different from
100%, but however, would still add to 400%. It can be seen from Table 2 that in the existing sys-
tem the clean air and coal/air flows are both unbalanced. It can also be observed that the two
unbalances are not similar due to the presence of orifices. Hence, it is proposed to retrofit the
whole orificing system based on the coal/air balancing. Since the two-phase flow in the existing
systems is quite complex and the data from standard handbook is unreliable, it was decided to

Table 1
Detail of four systems that exit from one pulverizer and feed the boiler at the same elevation
System Total vertical Total horizontal Bends in system Diameters of existing
length (m) length (m) orifices in system (mm)
1 10.39 48.11 150, 160, 160, 135 442 at 1 m distance
442 at 56 m distance
2 10.39 36.83 120, 135 437 at 1 m distance
437 at 45 m distance
3 10.39 64.34 165, 90, 135 442 at 1 m distance
4 10.39 75.62 135, 90, 160, 160, 135 No orifices
Note: Orifices are inserted according to the maximum pressure drop in the systems. Calculated pressure drop in system 4
is the maximum. Therefore, orifices were inserted in systems 1–3 to balance the pressure drop.

Table 2
Existing flow distribution for clean air and coal/air flows
System Clean air flow distribution (%) Coal/air flow distribution (%)
1 95 102
2 97 108
3 100 96
4 108 94
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 859

utilize the two-phase modelling technique to obtain the pressure data in each system. Then the
orifice diameters are recalculated based on the CFD results and a well-balanced system is
obtained.

5. CFD application to calculate pressure drop

As discussed in Section 2, the exact geometries of the individual systems in a power plant are
not always available. This problem was overcome by breaking up the geometry of the system into
various components like the horizontal section, vertical section, and various bends. The pressure
drop across each component is calculated and then put together to give the pressure drop along
the whole geometry of the system. Examples of the geometries used for the modelling are shown in
Fig. 2.
The pressure drops for the horizontal and vertical lengths were calculated initially for a 60D
pipe, where D is the diameter of the pipe. The pressure drops across unit length were then calcu-
lated and applied to the existing lengths of the pipe. A length of 60D was chosen to ensure that the
flow became fully developed. The pressure drop per unit length was calculated for the fully devel-
oped region. It was found that for the current configuration and flow condition (Reynolds number
9.15 · 105, surface roughness e = 0.0026 mm) the flow became fully developed within 30D from
the inlet. Therefore, for the bends, the upstream length was assumed to be 40D and downstream
to be 20D and the pressure drop across the bend was calculated.
For calculation of the steady state flow in the piping systems, continuity and momentum equa-
tions were solved along with the standard k–e turbulence model. Two-phase flow calculations
were adopted to simulate the air flow and coal particles. The equation of continuity for a mixed
fluid is expressed by Eq. (6), where a is the phase, ra is the volume fraction of that phase, qa is the
density of the fluid in the phase a, xj is the coordinate with the index j ranging from 1 to 3, and U ja
is the mean velocity in the phase a along the direction j. The continuity equation expressed for
each control volume is shown in Eq. (7).

Fig. 2. Schematics of the components modelled.


860 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

oðra qa Þ oðra qa U ja Þ
þ ¼ 0; ð6Þ
ot oxj
X X 1 oðra qa Þ oðra qa U j Þ
a
ra ¼ 1 or þ j
¼ 0; ð7Þ
a a
qa ot ox

where repeated indices imply summation from 1 to 3. The equation of motion is expressed by Eq.
(8)
oðra qa U ia Þ oðra qa U ia U ja Þ op oðra sji Þ
þ j
¼ ra i þ ra qa gi þ ; ð8Þ
ot ox ox oxj
where p is the pressure and sij is the stress tensor given by
 i 
oU oU j
sij ¼ leff þ i ; ð9Þ
oxj ox
where leff is effective viscosity, which is defined as the sum of dynamic viscosity l and eddy vis-
cosity lt, leff = l + lt. The eddy viscosity is provided by the k–e turbulence model.
k2
lt ¼ C l q ; ð10Þ
e
where Cl is a constant and is equal to 0.09, k is the turbulent kinetic energy, e is the dissipation
rate, and both are provided by the k–e turbulence model.
   

o o j l þ a ok a
ðra qa k a Þ þ j ra ðqa U a k a Þ  l þ ¼ ra ðP a  qa ea Þ þ T kab ; ð11Þ
ot ox rk oxj
   

o o l þ a oea ea
ðra qa ea Þ þ j ra ðqa U ja ea Þ  l þ ¼ ra ðC e1 P a  C e2 qa ea Þ þ T eab ; ð12Þ
ot ox re oxj ka
where rk = 1.0, re = 1.3, Ce1 = 1.44, and Ce2 = 1.92 are constants from the k–e model. T kab and T eab
are the terms that represent the inter-phase transfer for k and e respectively. P represents the shear
production due to turbulence for that particular phase, which is
 
oU j oU j oU k
P ¼ lt k þ j . ð13Þ
ox oxk ox
The continuity equation, momentum equation, and the turbulence model equation were solved
for each phase. The pipe diameter was 0.527 m. For clean air flow, the air density was taken as
1.284 kg/m3, which is the value at room temperature. For coal/air flow, the air density was
0.977 kg/m3, which is the value at 88 C, and the coal density was 1398 kg/m3. The coal flow rate
was 2.36 kg/s and the air flow rate was 5.00 kg/s.
The boundary conditions were assumed to be uniform velocity distribution at the inlet and zero
gage pressure (open to atmosphere) at the outlet. Grid refinement near the walls was used for grid
generation (Fig. 3). This allows for much better resolution of the velocity field near the wall where
it changes rapidly. Reynolds Averaged Navier–Stokes equations (RANS) were solved using finite
volume method on an unstructured mesh with the standard k–e model for turbulence.
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 861

Fig. 3. Cross-section and plan view of the unstructured grid.

A typical mesh size for the CFD simulation was around 300,000 mesh cells, each steady state
case took 11–16 wall clock hours on Dell Optiplex GX270 computers. These computers had 2
Intel P4 3.20 GHz processors with 2.00GB RAM. The steady state solutions used pseudo time
step, which was determined by the CFL requirement of the solver. Convergence was claimed when
a stable pressure drop was achieved, usually it took 7000 iterations.
The friction factor was calculated by using the pressure drop in the fully developed region of the
pipe. The friction factor for clean air was calculated by
DP
f ¼ ; ð14Þ
L 1
D 2
qU 2avg
where f is the friction factor, DP is the pressure drop along the pipe over a distance of L in the
fully developed region, q is the density of air, Uavg is the average velocity, and D is the diameter
of the pipe. For a fully developed flow, the friction factor is a constant. From this calculation, the
friction factor was found to be f = 0.0164. The results were compared to those in the Moody chart
(Reynolds number 9.15 · 105, surface roughness e = 0.0026 mm, friction factor f = 0.017).
The boundary conditions for the coal/air flow were imposed in the same manner as those for
clean air flow. The boundary condition for the particles was no slip i.e., the particles stick to the
surface if they hit the surface. The volume fraction for coal at inlet was considered to be uniformly
distributed. The coal particles were all considered to be spherical and of the same uniform size
(diameter 1 lm). Table 3 gives the pressure drop per unit length for the horizontal and vertical
components and also the pressure drop across the bends for both clean air and coal/air flows.
As can be seen, the pressure drop for the coal/air flow is always greater than that of the clean
862 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

Table 3
Pressure drop across various components for clean air and coal/air flows
Horizontal (Pa/m) Vertical (Pa/m) Bend angles
90 (Pa) 120 (Pa) 135 (Pa) 150 (Pa) 160 (Pa) 165 (Pa)
Clean air 11.02 10.82 48.68 32.06 23.93 13.79 9.18 5.71
Coal/air 27.52 16.6 104.33 51.76 29.63 15.64 11.47 8.38

air flow. It can be said that this is mainly due to the resistance offered by the interaction between
air and coal particles and among coal particles themselves, as well as blockage effects.

6. Results

In this study, orifice sizes were calculated for coal/air balancing. Based on the given data, the
calculations have been performed with the existing system configuration. The clean air and coal/
air pressure drop coefficients, and flow distributions were first calculated. Orifice sizes for coal/air
balancing were then calculated. Note that in each system if one or more orifices already exist, then
there was at least one orifice at 1-m distance from the pulverizer exit. It was then tacitly assumed
that the new orifice would replace that orifice.
Table 1 gives the data from the power plant. This table is self-explanatory. The existing flow
distributions are given in Table 2, which are based on the pressure drop calculations shown in
Table 3. The orifice diameters for balancing coal/air flow are shown in Table 4. The tailored clean
air flow and the balanced coal/air flow distribution after insertion of new orifices is shown in
Table 5. As can be seen from Table 5, the pressure drop for each system is the same and

Table 4
Orifice diameter calculation for coal/air balancing
System K Loss coefficient Existing orifice KOR Total K New KOR Orifice diameter (mm)
1 5.84 0.95 6.79 2.32 401.78
2 4.73 1.07 5.80 3.31 389.08
3 7.78 0.00 7.78 1.32 427.85
4 9.10 0.00 9.10 0.00 –
Note: K is the pressure loss coefficient of each system and KOR is the pressure loss coefficient of the orifice calculated
based on Eq. (4).

Table 5
Tailored clean air flow and balanced coal/air flow distribution after insertion of new orifices
System Clean air Coal/air
Total K after retrofit Flow distribution (%) Total K after retrofit Flow distribution (%)
1 5.25 91 9.10 100
2 6.01 85 9.10 100
3 3.88 105 9.10 100
4 3.01 120 9.10 100
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 863

consequently the coal/air flow is balanced. In each instance, an existing orifice at 1 m distance is to
be replaced by the new orifice.
The CFD simulations also provide detailed information of the two-phase flow field. Fig. 4
shows the close-up view of the air velocity magnitude contours for bends with various angles.
The gravity force is vertically downward (in the negative y-direction). All contours shown in Figs.
4 and 5 are on the center plane (xz-plane) that passes the axis of the bend. In the horizontal por-
tion of the bend, all flows exhibit similar velocity distributions and there is no variation in the

Fig. 4. Air velocity magnitude contours for bends with various angles.
864 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

Fig. 5. Contours of volume fraction of coal for bends with various angles.

streamwise direction. This is because the flow has gone through 40D upstream length before it
reaches the bend, and flow has become fully developed. It is observed that the velocity is lower
near the bottom of the horizontal portion. This is due to the higher resistance to the air induced
by the coal particles when they deposit to the pipe bottom. For the flow conditions considered in
the current study, the effects of coal particle deposition is significant. It can be clearly seen from
Fig. 4 that the characteristics of the air flow downstream of the bend strongly depend on the bend
angle. For sharp turns (Fig. 4a–c), the flow has to change direction quickly and the higher velocity
flow is shifted towards the outer radius of the downstream bend. While near the inner radius of
S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866 865

the bend, a lower velocity region can be identified. As shown in Table 3, this sharp flow direction
change results in significant pressure loss, with the 90 bend giving the highest. For higher bend
angles (Fig. 4d), the flow goes through the bend quite smoothly, and the pressure loss is insignif-
icant compared to the sharp turning cases.
Fig. 5 displays the contours of volume of fluid (VOF) of coal for bends with various angles. In
the horizontal portion, all bends show similar coal VOF distribution, just like the velocity con-
tours in Fig. 4. Higher coal VOF is found at the lower part of the upstream pipe. This is again
attributed to the deposition of the coal particles. In the bend, maximum VOF of coal can be iden-
tified near the outer radius of the bend. This is explained by the flow impingement in the bend, and
the attachment and accumulation of coal particles at this location. For sharp turning bends, the
overall VOF of coal becomes much less downstream of the bend, indicating significant deposition
and accumulation of coal particles in the bend and upstream pipe (Fig. 5a–c). While for smooth
turning bend, the effects of coal particle deposition and accumulation are not as prominent
(Fig. 5d). It should be pointed out that for the 90 bend, immediately downstream of the bend
and close to the inner radius, there is a localized region with a higher coal VOF than its local
ambient. This is the indication of flow separation. The local recirculating flow traps a significant
amount of coal particles and a region of higher VOF of coal is formed. For 120 and 130 bends,
this localized region can still be seen, but the size is much smaller. While for the 160 bend, it is not
recognizable, suggesting negligible or non-existent flow separation downstream of the bend.

7. Conclusions

There is currently no easy way of measuring coal/air flow in a power plant. In order to balance
the coal/air flow to the individual burners, it would, therefore, be necessary to rely on clean air
tests. The industry practice has so far been to balance the clean air flow and accept the resulting
imbalance in the coal/air flow. It was observed in one specific case that, when the clean air is bal-
anced with a maximum deviation of 3% from the average, the corresponding coal/air flow devi-
ation was approximately 27%. This is unacceptable from the consideration of efficient unit
operation.
A new method in which creating a tailored imbalance in clean air flow corresponding to a bal-
anced coal/air flow distribution has been successfully proposed in this paper. Commercially avail-
able software CFX was used to calculate pressure drops in systems. The two-phase flow
phenomena was simulated using the multi-phase modelling technique. Using this, several geom-
etries involving any number of independent lines starting from a mill and discharging to a given
burner can be handled. The results show that the pressure drop in the systems strongly depends on
the system geometry. Orifices are sized based on calculated coal/air pressure drops, and finally
imposing a tailored imbalance in clean air flow distribution leading to a balanced coal/air distri-
bution. It should be pointed out that in order to implement this method in power plant, verifica-
tion can still be done by measuring the tailored clean air distribution. The numerical results also
provide detailed information of the two-phase flow field in the piping systems in a power plant,
based on which physical insights were obtained and better understanding of the complex flow phe-
nomena was achieved. This study demonstrated that CFD can be used as an effective tool for
design and research for power industry applications.
866 S. Vijiapurapu et al. / Applied Mathematical Modelling 30 (2006) 854–866

References

[1] A.A. Vetter, R.S. Vetter, Balancing pulverized coal flows in parallel piping, J. Eng. Gas Turb. Power 107 (July)
(1985) 679–684.
[2] R. Avancha, Coal/air balancing in pulverized coal fired units, MasterÕs Thesis, Tennessee Technological University,
1995.
[3] M.P. Sharma, Numerical and experimental study of gas-particle flows in orifices and venturis: application to
flowmeter design, Ph.D. Dissertation, Washington State University, 1977.
[4] G.R. Jones, Pulverized Coal Mill Fuel/Air Ratio Testing, paper presented at EPRI Heatrate Improvement
Conference, Knoxville, Tennessee, September 1989.
[5] ASHRAE Handbook Fundamentals-2001, I.P. Edition.
[6] AEA Technology, CFX-5.5.1 Flow Solver User Guide, AEA Technology Inc., 2003.
[7] C. Yin, L. Rosendahl, S.K. Kar, T.J. Condra, Use of numerical modeling in design for co-firing biomass in wall-
fired burners, Chem. Eng. Sci. 59 (2004) 3281–3292.
[8] C.N. Eastwick, S.J. Pichering, A. Aroussi, Comparisons of two commercial computational fluid dynamics codes in
modeling pulverized coal combustion for a 2.5 MW burner, Appl. Math. Modell. 23 (1999) 437–446.
[9] G.J. Brown, Erosion prediction in slurry pipeline tee-junctions, Appl. Math. Modell. 26 (2002) 155–170.
[10] D. Achim, A.K. Easton, M.P. Schwarz, P.J. Witt, A. Zakhari, Tube erosion modelling in a fluidised bed, Appl.
Math. Modell. 26 (2002) 191–201.
[11] P.J. Stopford, Recent applications of CFD modelling in the power generation and combustion industries, Appl.
Math. Modell. 26 (2002) 351–374.
[12] A.A. Vetter, Theoretical Evaluation of the Differences Between Single and Two-Phase Flow as Applied to Coal
Transport Piping, Humburg Mountain Research Laboratories Report, HMRL R—31:1, September 1981.
[13] I.E. Idelchik, Handbook of Hydraulic Resistance, third ed., CRC Press, Inc., Boca Raton, 1994, p. 221.