Professional Documents
Culture Documents
DELTEC ENGINEERING
OILY WATER SEPARATOR (BASE SLAB) CALCULATION
Client PROMENADE Made by Date Page
Location IJEGUN-EGBA, LAGOS FIO 08-Jun-2018 1
Crack Width Calculations to BS8110: 1997/ BS8007:1987 Checked Revision Job No
INPUT
fcu= 30 N/mm2
fy= 410 N/mm2
Area of reinforcement " As " = 565 mm2
b= 1000 mm
h= 200 mm
d= 144 mm
Minimum cover to tension reinforcement " CO " = 50 mm
Maxmum bar spacing " S " = 200 mm
Bar dia " DIA " = 12 mm
" acr " =(((S/2)^2+(CO+DIA/2)^2)^(1/2)-DIA/2) as default or enter other value = 108.6 mm
"acr " is distance from the point considered to the surface of the nearest longitudinal bar
Applied service moment " Ms "= 5.9 KNm
CALCULATIONS
moduli of elasticity of concrete " Ec" = (1/2)*(20+0.2*fcu) = 13.0 KN/mm2
moduli of elasticity of steel " Es " = 200.0 KN/mm2
Modular ratio " a " = (Es/Ec) = 15.38
" r " = As/bd = 0.004
depth to neutral axis, "x" = (-a.r +((a.r)2 + 2.a.r)0.5.d = 42 mm
Disclaimer
All advice or information from the British Cement Association and/or Reinforced Concrete Cou
intended for those who will evaluate the significance and limitations of its contents and take
responsibility for its use and application. No liability (including that for negligence) for any lo
resulting from such advice or information is accepted by the BCA, RCC or their subcontractors
suppliers or advisors. Users should note that all BCA software and publications are subject to
revision from time to time and should therefore ensure that they are in possession of the late
version.
This spreadsheet should be used in compliance with the accompanying publication 'Spreadsh
concrete design to BS 8110 & EC2' available from British Cement Association, Telford Avenue,
Crowthorne, Berkshire RG45 6YS.
Status of spreadsheet
Public release version.
Page 2
Notes
Size (kB)
81
Page 3