You are on page 1of 17

JunaidS47

JunaidS47
Wall Formwork
Design
JunaidS47 Structural Consultant Date : June 1, 2018

Civil Engineering Time : 8:04:26

Job. No. : WFD/01/JS47/11/2008 Engineer : Junaidi


House Design, Serpong
Job. Title : Approved : Junaidi

Name Junaidi
Address Sidodadi X/83
City Surabaya
Telp / Hp +62813 578 30000
Job Address -
Surabaya
Rumah Sakit
Description

Job Analysis Contents

1. Data Input

2. Multiplex Design

3. Vertical Beam Design

4. Horizontal Beam Design

5. -

6. -

Notes

Notes For Example

Instruction
www.junaids47.wordpress.com
: Input Data Cell www.civilconstruction.co.cc
www.civil-constructionmethod.blogspot.com
FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element WALL FORMWORK DESIGN DATA JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Structure Model Drawing

tc

▪ Dimension
Height of Formwork (H) = 3000 mm
Thickness of Wall ( tc ) = 350 mm

■ Specification Material Property Data


▪ Concrete Material Property Data
Weight per Unit Volume ( γc ) = 2400 kg/m3

▪ Multiplex Material Property Data


Class of Wood II
Modulus of Elasticity ( Ew ) = 100000 kg/cm2
Permissible Bending Stress ( σℓt ) = 100 kg/cm2
Permissible Fibre Parallel Compression Stress ( σtk// ) = 85 kg/cm2
Permissible Fibre Vertical Compression Stress ( σtk┴ ) = 25 kg/cm2
Permissible Fibre Parallel Tension Stress ( σtr// ) = 85 kg/cm2
Permissible Fibre Parallel Shear Stress ( τ// ) = 12 kg/cm2

▪ Wood/Timber Material Property Data


Class of Wood II
Modulus of Elasticity ( Ew ) = 100000 kg/cm2
Permissible Bending Stress ( σℓt ) = 100 kg/cm2
Permissible Fibre Parallel Compression Stress ( σtk// ) = 85 kg/cm2
Permissible Fibre Vertical Compression Stress ( σtk┴ ) = 25 kg/cm2
Permissible Fibre Parallel Tension Stress ( σtr// ) = 85 kg/cm2
Permissible Fibre Parallel Shear Stress ( τ// ) = 12 kg/cm2
FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element MULTIPLEX DESIGN - 1 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Model of Structure

LVB LVB

q
3500

3000

2500

LVB LVB 2000

■ General Data 1500

▪ Dimension Property Data Per Meter 1000


Plywood Thickness ( t) = 1.8 cm
Areas ( A ) = 180 cm2 500

Moment Inersia ( I ) = 48.6 cm4 0


3

Section Modulus ( S ) = 54 cm3 -20 -10 0 10 20 30 40 50 60 70 80

▪ Loads Property Data Per-Meter


Cause thickness of wall is to small when I'ts compare with the height of wall so the pressure of concrete
divide to each wall side (Pressure at the bottom wall can be multiplied by koefficient of thickness)
1 tc
Cth = ×
2 1000 q = Cth × γc × H
1 350 = ( 0.175 ) × ( 2400 ) × (3)
= ×
2 1000 = 1260 kg/m
= 0.175 = 12.6 kg/cm

Shock Load Cause of Concrete Pump Total Load


qS = 500 kg/m qTot = 17.6 kg/cm
= 5 kg/cm

FORMWORK WALL DESIGN


Project X - PROJECT JunaidS47
Design Element MULTIPLEX DESIGN - 2 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Analysis Minimum Length Span of Multiplex


▪ Minimum Length Cause of Moment
M 1
σℓt ≥ Mmax ≥ qL2
S 10
Mmax ≤ σℓt × S 1
5400 ≥ ( 17.6 ) L2
≤ 100 × 54 10
≤ 5400 kg-cm L ≤ 55.39 cm

▪ Minimum Length Cause of Shear


V 1
τ// ≥ 1.5 m Vm = qL
A 2
τ// A 2 Vm
6.3 L

Vm ≤ L ≤
1.5 q
( 12 ) ( 180 ) 2 ( 1440 )
≤ =
1.5 17.6
≤ 1440 kg ≤ 163.64 cm
0,5L

▪ Minimum Length Cause of Deflection


∆per = 3 mm ∆ijin ≥ ∆T
5 q L4 0.3 ≥ 4.715E-08 L 4
∆T =
384 E I L 4 ≤ 6E+06
5 ( 17.6 ) L 4 L ≤ 50.22 cm
=
384 ( 100000 ) ( 48.6 )
= 4.715E-08 L 4

▪ Length of Span (Distance of Vertical Beam)


L≤ 50.22 cm
≤ 502.23 mm

Use : LVB = 306.25 mm


when I'ts compare with the height of wall so the pressure of concrete
FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element VERTICAL BEAM DESIGN - 1 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-
■ Model of Structure

LHB

LHB
LHB

LHB

Multiplex
Vertical Beam
Horizontal Beam
3500

3000

2500

LHB LHB
2000

■ General Data 1500

▪ Dimension Property Data


1000
Dimension of Wood 50x100
Width = 50 mm 500
Depth = 100 mm
3
Areas (A) = 50.00 cm2 0
-20 -15 -10 -5 0 5 10 15 20 25
Moment Inersia (I) = 416.67 cm4
Section Modulus (S) = 83.33 cm3

▪ Loads Property Data Per-Meter


Cause thickness of wall is to small when I'ts compare with the height of wall so the pressure of concrete
divide to each wall side (Pressure at the bottom wall can be multiplied by koefficient of thickness)
1 tc
Cth = ×
2 1000 q = Cth × γc × H × LVB
1 350 = ( 0.175 ) × ( 2400 ) × (3) × ###
= ×
2 1000 = 385.88 kg/m
= 0.175 = 3.86 kg/cm
Shock Load Cause of Concrete Pump Total Load
qS = 500 × LVB qTot = 5.39 kg/cm
= 500 × 0.30625
= 153.13 kg/m = 1.53 kg/cm

FORMWORK WALL DESIGN


Project X - PROJECT JunaidS47
Design Element VERTICAL BEAM DESIGN - 2 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Analysis Minimum Length of Span


▪ Minimum Length Cause of Moment
M 1
σℓt ≥ Mmax ≥ qL2
S 8
Mmax ≤ σℓt × S 1
8333 ≥ ( 5.39 ) L2
≤ 100 × 83.33 8
≤ 8333.33 kg-cm L ≤ 111.21 cm

▪ Minimum Length Cause of Shear


V 1
τ// ≥ 1.5 m Vm = qL
A 2
1.929375 L

τ 2 Vm
Vm ≤ // A L ≤
1.5 q
( 12 ) ( 50 ) 2 ( 400 )
≤ =
1.5 5.39
≤ 400 kg ≤ 148.42 cm
0,5L

▪ Minimum Length Cause of Deflection


∆per = 3 mm ∆ijin ≥ ∆T
5 q L4 0.3 ≥ 1.684E-09 L 4
∆T =
384 E I L 4 ≤ 2E+08
5 ( 5.39 ) L 4 L ≤ 115.52 cm
=
384 ( 100000 ) ###
= 1.684E-09 L 4

▪ Length Span of Vertical Beam (Distance of Horizontal Beam)


L≤ 111.21 cm
≤ 1,112.14 mm

Use : LHB = 600 mm


FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element HORIZONTAL BEAM DESIGN - 1 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Model of Structure

LHB

LHB

Multiplex LSp LSp


Vertical Beam
Horizontal Beam

LHB LHB

■ General Data
▪ Dimension Property Data Per Meter
Dimension of Wood 50x100
Width = 50 mm
Depth = 100 mm
Areas ( A ) = 50.00 cm2
Moment Inersia ( I ) = 416.67 cm4
Section Modulus ( S ) = 83.33 cm3

▪ Loads Property Data Per-Meter


Cause thickness of wall is to small when I'ts compare with the height of wall so the pressure of concrete
divide to each wall side (Pressure at the bottom wall can be multiplied by koefficient of thickness)
1 tc
Cth = ×
2 1000 q = Cth × γc × H × LHB
1 350 = ( 0.175 ) × ( 2400 ) × (3) × ( 0.6 )
= ×
2 1000 = 756 kg/m
= 0.175 = 7.56 kg/cm
Shock Load Cause of Concrete Pump Total Load
qS = 500 × LHB qTot = 10.56 kg/cm
= 500 × 0.6
= 300 kg/m = 3 kg/cm

FORMWORK WALL DESIGN


Project X - PROJECT JunaidS47
Design Element HORIZONTAL BEAM DESIGN - 2 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:27


-

■ Analysis Minimum Length of Span


▪ Minimum Length Cause of Moment
M 1
σℓt ≥ Mmax ≥ qL2
S 8
Mmax ≤ σℓt × S 1
8333 ≥ ### L2
≤ 100 × 83.33 8
≤ 8333.33 kg-cm L ≤ 79.46 cm

▪ Minimum Length Cause of Shear


V 1
τ// ≥ 1.5 m Vm = qL
A 2
τ// A 2 Vm
3.78 L

Vm ≤ L ≤
1.5 q
( 12 ) ( 50 ) 2 ( 400 )
≤ =
1.5 10.56
≤ 400 kg ≤ 75.76 cm
0,5L

▪ Minimum Length Cause of Deflection


∆per = 3 mm ∆ijin ≥ ∆T
5 q L4 0.3 ≥ 3.3E-09 L 4
∆T =
384 E I L 4 ≤ 9E+07
5 ### L 4 L ≤ 97.65 cm
=
384 ( 100000 ) ###
= 3.3E-09 L 4

▪ Length Span of Horizontal Beam (Distance of Support)


L≤ 75.76 cm
≤ 757.58 mm

Use : LSp = 400 mm


FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element TIE ROD DESIGN - 1 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:28


-

■ Model of Structure

Tie Rod
LHB

LHB

Multiplex LTR LTR


Vertical Beam
Horizontal Beam

LHB LHB

■ General Data
▪ Dimension Property Data Per Meter
Diameter of Tie Rod ( D ) = D-13 mm
Reinforced Yield Stress ( fy ) = 400 MPa
Modulus of Elasticity ( Es ) = 200000 MPa
Area of Tie Rod (A) = 132.73 mm2

▪ Loads Property Data Per-Meter


Cause thickness of wall is to small when I'ts compare with the height of wall so the pressure of concrete
divide to each wall side (Pressure at the bottom wall can be multiplied by koefficient of thickness)
1 tc
Cth = ×
2 1000 q = Cth × γc × H
1 350 = ( 0.175 ) × ( 2400 ) × (3)
= ×
2 1000 = 1260 kg/m
= 0.175

Shock Load Cause of Concrete Pump Total Load


qS = 500 kg/m qTot = 1760 kg/m
FORMWORK WALL DESIGN
Project X - PROJECT JunaidS47
Design Element TIE ROD DESIGN - 2 JunaidS47
Engineer JUNAIDI Date : June 1, 2018

Revision Time : 8:04:28


-

■ Analysis Minimum Distance of Tie Rod


▪ Strength of Tie Rod Drat
- Strength of Tie Rod Tie Rod
F = fy × A
= 400 × 132.73
= 53093 N
= 5412.12 kg
- Strength Joint of Tie Rod (Assumption) - Strength Joint of Tie Rod (Test)
FJ = 0.25 × F FJ = - kg
= 0.25 × 5412.12
= 1353 kg FJ = 1,353.03 kg

▪ Minimum Distance
Num of Tie Rod (Vertical Way) : n = 6
- Strength of Tie Rod
F = n × FJ
= 6 × 1,353.03
= 8,118.18 kg

- Coefficient Load of Tie Rod


CLTR = 1.000 CTRL = 0, Tie Rod Not Recveive Load & Support Receive All Load;
CTRL = 1, Tie Rod Recveive All Load & Support Not Receive Load;

- Force of Load
Fu = ( q × LTR × H ) × CLTR
= ( 1760 × LTR × 3.00 ) × 1.000
= ( 5280 × LTR ) × 1.000
= 5280 LTR

F ≥ Fu
F ≥ 5280 LTR
F
LTR ≤
5280
8,118.18

5280
≤ 1.54 m
≤ 153.75 cm

▪ Length Span of Horizontal Beam (Distance of Support)


L≤ 153.75 cm
≤ 1,537.53 mm

Use : LTR = 734.07 mm