ENTERPRISE NETWORK ADMINISTRATION I
PREPARED BY:
ABEL BEKELE ATE/9478/08
System Infrastructure:
servers
networking
storage and
security
Applications:
Infrastructure mapping & Topology
- Information security is also a concern, and for this reason a MOST data center has a
secure environment which minimizes the chances of a security breach. The data center
keep high standards for assuring the integrity and functionality of its hosted computer
environment. This is accomplished through redundancy of both fiber optic cables and
power, which includes emergency backup power generation.
Mini exhibition:
The mini exhibition is built with MOST and the collaboration of Huawei to encourage
enterprise for a new innovation and projects which are sponsored and displayed in the
company. This mini exhibition room contains several things which are created in the
company. For example the machine that write and draws anything on a piece of hard board.
In addition to that there is the 3D printing machine this machine is being used know a
days for modeling and also for proto type. Before doing the actual product it must be
modeled so the 3D model will be printed by the printer. This machine will reduce the cost of
prototyping or modeling. Especially the health center have been using the 3D model on
creating the skeleton of the human being and other equipment’s.
Design Considerations:
MOST data center occupy one room of a building from underground, Most of the
equipment is often in the form of servers mounted in 19 inch rack cabinets, which are usually
placed in single rows forming corridors between them. Corridors allows people access to the
front of each cabinet. Some equipment such as mainframe computers and storage devices are
often as big as the racks themselves, and are placed alongside them.
Architectural Design:
MOST architecture of the building it self is nice and big for IT infrastructure they design
best room for data center, engineering infrastructure design and inside the data center mechanical
systems are designed and build such as cooling and electrical systems including power and cable
plant.
MOST data center has raised the floor around 25 centimeter above from the ground. And
all the cabling infrastructure is hidden below the raised floor it almost consists everything like
linkage sensor, AC (air conditioning) pipes, power cable and fiber optics.
To do Maintenance the square floors are removable we can relocate them after we finish
our work.
This data center consists around six rooms:-
These are:
power room
communication room
ups room
maintenance room
power termination room
network operation control room
Modeling Criteria:
The future-state scenarios for space, power, cooling, and costs. IT floor system layouts,
and power and cooling technology and configurations are not good if the data center is growing
significantly it is difficult. But they have empty rack cabinets so they can move the rack and add
another rack.
- Doors: the doors are electronic and magnetic we can access them with card and key.
These are fire proof doors and when something happens they automatically open to
emergency exit.
Power System:
Power system is one of the critical system that must be provided efficiently to call they
have datacenter. According to ISO (International Standardize Organization) for a data center
standard down time is less than 2 minutes/year other ways it’s a failure.
From Ethiopia Electric Corporation because its critical they have a high-level transformer
that maintain power when its high and even observe until generator is on.
In case the Ethiopia Electric Corporation down providing the power needed the second
backup is the Generator with the power of 800KVA work 24/7 with fuel. In case the generator
stops working there are 3 UPS batteries with power of 120 KVA each with 360KVA total can
work more than 5hours at peak level.
In case the third backup fail which didn’t happen still know there is UPS battery for the
office building measured 300KVA.
Fire protection:
The data center include fire protection systems, including passive and active design
elements, as well as implementation of fire prevention programs in operations. Smoke detectors
are installed to provide early warning of a fire at its incipient stage.
The firefighting systems uses the fire proof window with fire proof doors which stops the
fire from spreading out on top of that in case the fire has gone out the wall is also a fire proof
wall. In addition to that there is a fire alarm system.
Passive fire protection elements included in the installation of fire walls around the data
center, so a fire can be restricted to a portion of the facility for a limited time in the event of the
failure of the active fire protection systems. Fire wall penetrations into the server room, such as
cable penetrations, coolant line penetrations and air ducts are provided with fire rated penetration
assemblies, such as fire stopping.
Alarm:
When we see Alarm triggers they make siren inside out by detecting fire/ smoke, unusual
activities.
Network switch:
A network switch is a computer networking device that links network segments or network
devices. The term commonly refers to a multi-port network bridge that processes and routes data at the
data link layer (layer 2) of the OSI model.
A switch is a telecommunication device that receives a message from any device connected to it
and then transmits the message only to the device for which the message was meant.
There are two high core switches in the data center each weighting around 300 kilograms.
And both the switches have a 40 GB(giga bit) interfaces for high input and output but also for
high connectivity between the networks.
Cloud services like kbl are also included for creating a virtual machine and two grid
server for creating java virtual machine because they require more storage and this servers
weights around 160kg each. In order for the organization to use it also have 32 Rak server and
above 50 access switches. Every server is consisted with an admin port besides to the service
port which helps us to do all the physical activity on that port without any interactions.
Switches:
There are 2 core switches weighted 300 KG, these devices provide security for the data
center as well they provide 40 GB interface integrated with firewalls like stack to provide high
speed connection between servers and to fasten input and output data.
HUAWEI CloudEngine 12800 Series Data Center Switches
CE12800 offers carrier-grade reliability, virtualization support, iStack clustering, and
Software-Defined Networking features for building and scaling data centers and campus
networks. CE12800 switches provide versatility and resilient performance for server-based
multimedia applications, Big Data analytics, and cloud computing.
Elastic switching meets your specialized requirements. 576 x 100 GE, 576 x 40 GE,
2,304 x 25 GE, or 2,304 x 10 GE ports with total switching capacity of 178 Tbit/s per switch,
upgradable to 1,032 Tbit/s.
Storage:
The storage used by the MOST data center is round 2 Pb. This means it can be used around 5
years efficiently without any excessive wastage.
Fiber cable:
There are 2 fiber cable with 50 Mb(mega bit) and another fiber cable also with 50 Mb
with the total of 150 Mb provided by our ISP(Ethio Telecom).
Server:
There are 2 high end servers weighted 320 KG a piece they are used for cloud service for
affiliate organizations and for KVM (virtual machine) purpose.
There are 2 grid servers for creating java virtual machine because they require more storage and
more speed.
Firewall:
There are 2 firewalls weighted 160 KG, these devices provide security for the data center
as well they provide 40 GB interface integrated with core switches like stack to provide high
speed connection between servers and to fasten input and output data.
Cloud Computing:
The initializing part of this topology is the cloud when one –off tasks are too much for
local it resources to cope with and investments are not economically viable, cloud computing is
the answer. The advantage of cloud service such as infrastructure as a service (IaaS). Then the
packet is sent to the router.
Applications:
The first application for MOST Network infrastructure:
iStack technology:
Intelligent stack (iStack) technology combines multiple switches into a virtual switching
device. Stacking technology provides high network reliability and scalability, while simplifying
network management.
High reliability: Member switches in a stack work in redundancy mode. Inter-
device Eth-Trunk links can also be set up between the member switches to
implement link redundancy.
High scalability: By combining physical switches into a stack, we can easily
increase the number of ports, bandwidth, and processing capability without
changing the network topology.
Simple configuration and management: we can log in to a stack from any member
switch to manage and configure all the member switches in the stack. In addition,
complicated Layer 2 ring protection protocols (such as MSTP) or Layer 3
protection switching protocols (such as VRRP) are not required after switches set
up a stack; therefore, the network configuration is much simpler.