The fuel gas for the process will come from two sources: process off-gas from the CDW Unit and imported fuel gas from the existing Dumai Refinery. The process off-gas and imported gas differ in their properties including specific gravity, molecular weight, net heating value, and composition by mole percentage of components like H2, C1, C2, C3. The normal and maximum operating temperatures and pressures are specified for both the process off-gas and imported natural gas.
The fuel gas for the process will come from two sources: process off-gas from the CDW Unit and imported fuel gas from the existing Dumai Refinery. The process off-gas and imported gas differ in their properties including specific gravity, molecular weight, net heating value, and composition by mole percentage of components like H2, C1, C2, C3. The normal and maximum operating temperatures and pressures are specified for both the process off-gas and imported natural gas.
The fuel gas for the process will come from two sources: process off-gas from the CDW Unit and imported fuel gas from the existing Dumai Refinery. The process off-gas and imported gas differ in their properties including specific gravity, molecular weight, net heating value, and composition by mole percentage of components like H2, C1, C2, C3. The normal and maximum operating temperatures and pressures are specified for both the process off-gas and imported natural gas.
1) Fuel Gas Basically process off-gas from the CDW Unit will be utilized. The balance of the fuel gas requirement will be imported from the existing Dumai Refinery.
Property and Battery Limit Condition
Process Off-Gas (*1) Imported
Property 100N EOR 150N SOR NP (*3) LPG Sp. Gravity (Air = 1.00) 0.414 0.418 0.6696 1.8 Molecular Weight 11.98 12.12 - 52.4 NHV, kcal/Nm3 7086 7132 8164 25500 HHV, kcal/Nm3 7884 7945 8164 ― Composition (mole%) H2O 0.42 0.41 ― ― H2S 0.02 0.02 3000 ppm ― CO ― ― ― ― CO2 ― ― ― ― N2 ― ― ― ― H2 72.74 71.35 53.90 C1 10.84 10.90 22.08 0.35 C2= ― ― 1.26 ― C2 1.68 1.66 10.65 ― C3= ― ― 0.80 ― C3 5.13 6.39 5.71 40.99 C4= - - 0.80 0.05 iC4 3.27 4.67 3.41 30.45 nC4 2.84 4.29 0.41 26.48 C5+ 3.04 0.31 1.68 C5= ― ― iC5 0.51 nC5 0.25 C6+ 0.22 Total 100.0 100.0 100.0 100.0 Battery Limit Condition Temperature, oC Normal 38 45 Mechanical Design 95 80 Pressure, kg/ ㎠ (g) Min/Nor/Max 2.0/3.5/3.5 2.6/3.0/3.5 Mechanical Design 5.6 5.3 Note) 1. Basically, process off-gas from the CDW unit will be utilized. 2. The balance of the fuel gas requirement will be supplied from LPG Vaporizer. 3. Pertamina UP-2 New Plant (HDC)